institut national de métrologie (lne-inm/cnam) workshop 732 – november 23-24, 2006 1 past...

20
1 Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 Past Improvements of the INM type Argon Device and Future Ways

Upload: shanon-wilcox

Post on 04-Jan-2016

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

1Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Page 2: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

2Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

G. Bonnier, 1974

Page 3: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

3Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Main faults:

-Sensitive to pressure change (atmospheric + hydrostatic)

- Immersion condition changing with time

Main advantages:

- Simple to use

- No electronic devices

Page 4: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

4Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Sensitive to atmospheric and hydrostatic pressure changes ?

Solution ?

Sensitive to atmospheric and hydrostatic pressure changes ?

Solution ?

Page 5: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

5Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Sensitive to atmospheric pressure changes ?

Solution ?

Page 6: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

6Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

1990 : The argon triple point by an adiabatic method –INM internal report

Page 7: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

7Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

1990 : The argon triple point by an adiabatic method – F. Roussel – INM internal report

Page 8: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

8Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Main faults:

- Not so easy to use

- Immersion condition changing with time

Main advantages:

- non sensitive to pressures changes

Page 9: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

9Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

Not useful ?

N2 heat pipes

Argon gas

Liquid argon

1985

Page 10: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

10

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

1985 : the argon triple point: Study of the thermal conditions –INM – internal report

Page 11: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

11

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

1990 : An adiabatic calorimeter for calibration at the argon triple point –

INM- Tempmeko90

Page 12: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

12

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

Maintaining the guard cell

Page 13: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

13

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

2002 – “Argon Triple Point Device to Calibrate Long Stem Thermometers in Quasi Adiabatic Conditions” “Temperature” chicago

Page 14: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

14

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

Page 15: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

15

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

How to improve the immersion condition

Page 16: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

16

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Future ways ?

Main faults on the “actual” system

-Sensitive to pressure change (atmospheric + hydrostatic)

- Immersion condition changing with time

Pressure regulation :

Reference: vacuum or temperature?

Page 17: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

17

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Future ways ?

Our choice

Pressure regulator

thermometer

Page 18: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

18

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Future ways ?

Main faults on the “actual” system

-Sensitive to pressure change (atmospheric + hydrostatic)

- Immersion condition changing with time

Level of liquid nitrogen ?

Page 19: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

19

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Future ways ?

Our choices

Pressure regulator

Insulations

thermometer

Liquid nitrogen

Page 20: Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006 1 Past Improvements of the INM type Argon Device and Future Ways

20

Institut National de Métrologie (LNE-INM/CNAM) Workshop 732 – November 23-24, 2006

Past Improvements of the INM type Argon Device and Future Ways

Future ways ?

Our choicesPressure regulator

Liquid nitrogen

Filling tube

Guard cell

Experimental space (vacuum)

Thermal shield

Main cell