  • First printed 1988

    ERITECH SYSTEM 3000 INSTALLATION,OPERATION AND MAINTENANCE MANUALDue to ongoing research into the phenomena of lightning and lightning protection technology and product improvement, ERICO reserves the right to alter any information and specifications contained herein at any time without notice. Installers of ERITECH SYSTEM 3000 should check that they have the latest edition.This manual replaces HB-HBCR-134 (Issue 1) edition number 6-2000.The ERITECH SYSTEM 3000 is manufactured by ERICO.

    International patents on the ERITECH SYSTEM 3000 are existing and pending.ERITECH SYSTEM 3000 (or any other lightning protection system) does NOT offer 100% protection against all lightning events. However, correct installation is essential for the maximum level of safety.

    Details of ERITECH SYSTEM 3000 Lightning Protection System

    System Owner:

    Location:

    Date Installed:

    Installation Contractor:

    Purchased From:

    Signature of Installation Contractor:

    EDITION 14

    HB-HBCR-169 REVISION 2

    Copyright 2009 ERICO International Corporation. All rights reserved.CADDY, CADWELD, CRITEC, ERICO, ERITECH, ERIFLEX, and LENTON

    are registered trademarks of ERICO International Corporation.

    E1498IS06EN:Manual 8/10/09 10:59 AM Page 2

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL

    www.erico.com

    The ERITECH SYSTEM 3000 Installation, Operation

    and Maintenance Manual

    HB-HBCR-169

    1

    E1498IS06EN:Manual 8/10/09 10:59 AM Page 3

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL

    2 www.erico.com

    Table of Contents

    Pre-Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4Grounding Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5 Downconductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5

    Structural Bonding Braid & Conductive Structural Points . . . . . . . . . . . . . . . . . . . Page 6Lightning Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6ERITECH DYNASPHERE Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6Masts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7

    Checking Lightning Protection Components on Receipt . . . . . . . . . . . . . . . . . Page 8

    ERITECH SYSTEM 3000 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9Grounding Systems Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9

    Ground Resistance Lowering Compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12Insulation of Grounding Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12Bonding the Lightning Protection Ground to other Service Grounds . . . . . . . . . Page 12Labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13

    Downconductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14Downconductor Hauling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14Penetrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16Securing the Downconductor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18Use of Mast or Conventional Cable as the Downconductor . . . . . . . . . . . . . . . . Page 19Labelling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20Structure Bonding Braid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 20Terminating the ERITECH ERICORE Lower End . . . . . . . . . . . . . . . . . . . Page 24Terminating the ERITECH ERICORE Upper End . . . . . . . . . . . . . . . . . . . Page 28

    Terminals and Masts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 40Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 40Masts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 40Mast Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 41Mast Couplings & Guying Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 42Guying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 44Raising of Mast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 45

    Lightning Event Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 48Long Lengths of ERITECH ERICORE Downconductor . . . . . . . . . . . . . . . . . . . .Page 49Parallel ERITECH ERICORE cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 51

    Series connected ERITECH ERICORE cable sections . . . . . . . . . . . . . . . . . . . . . . . Page 52Practical Examples for long lengths of ERITECH ERICORE . . . . . . . . . . . . . . . Page 54

    Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 55

    Operation & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 55Maintenance Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 58

    Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 59

    Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 62

    Certificate of Compliance and Warranty Registration . . . . . . . . . . Inside Back Cover

    E1498IS06EN:Manual 8/10/09 10:59 AM Page 4

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL

    3www.erico.com

    ERITECH SYSTEM 3000

    Due to ongoing research into the phenomena of lightning, lightning protectiontechnology and product improvement, ERICO reserves the right to alter anyinformation and specifications contained herein at any time without notice.

    Users should check with ERICO to ensure they have the latest edition.

    THE ERITECH SYSTEM 3000 Installation, Operation

    and Maintenance Manual

    Local Distributors should be the users first point of contact with supply, delivery, installation,limited warranty, and checking of the system for compliance with Manufacturers instructions.

    Warning:1. ERICO products shall be installed and used only as indicated in ERCIO product instructionsheets and training materials. Instruction sheets are available at www.erico.com and from yourERICO customer service representative.

    2. ERICO products must never be used for a purpose other than the purpose for which theywere designed or in a manner that exceeds specified load ratings.

    3. All instructions must be completely followed to ensure proper and safe installation andperformance.

    4. Improper installation, misuse, misapplication or other failure to completely follow ERICOsinstructions and warnings may cause product malfunction, property damage, serious bodilyinjury and death.

    The customer is responsible for:a. Conformance to all governing codes.b. The integrity of structures to which the products are attached, including their

    capability of safely accepting the loads imposed, as evaluated by a qualifiedengineer.

    c. Using appropriate industry standard hardware as noted above.

    SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the jobsite must be observed. Always use appropriate safety equipment such as eye protection, hardhat, and gloves as appropriate to the application.

    The ERITECH SYSTEM 3000 is manufactured by ERICO.

    International patents on the ERITECH SYSTEM 3000 are existing.

    E1498IS06EN:Manual 8/10/09 10:59 AM Page 5

  • INSTALLATION, OPERATION AND MAINTENANCE MANUAL

    4 www.erico.com

    This manual is a guide to the Installation,Operation and Maintenance of theERITECH SYSTEM 3000 LightningProtection System.

    It assumes that the system to be installedhas been designed by an authorized ERICO

    representative. The system design willinclude:

    Grounding system design - a configuration should be designed as a result of soil resistivity analysis.

    Downconductor routes - chosen to avoid other services, maintain minimum bending radii and minimize downconductor run length.

    Downconductor securing requirements.

    Terminal types - operating environment.

    CAD analysis design software whichdetermines terminal placement, mast &height requirements as well as protectionlevel calculation.

    All of the above are recommended for asuccessful installation. If there is any doubtabout any of the points mentioned, pleasecontact ERICO or your nearest Distributorfor clarification.

    Only attempt to install the ERITECH SYSTEM 3000 du