installation instructions regolo r14 all ount v /indirect ... · installation instructions regolo...

6
Installation Instructions Regolo RW14 Wall Mount V/Indirect, D/Direct, B/Bi-Direct Sheet Rock Surface Mount NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 1 WARNINGS: •Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. •Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main- tenance. INDIVIDUAL FIXTURES CONTINUOUS ROW FIXTURES AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta- tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo- cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance. ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes de mantenimiento. DISTORT JOINT

Upload: others

Post on 24-May-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 1

WARNINGS:•Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced.

•Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main-tenance.

INDIVIDUAL FIXTURES CONTINUOUS ROW FIXTURES

AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta-tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo-cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance.

ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes

de mantenimiento.

DISTORT JOINT

Page 2: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 2

Lighting SyStem ComponentS

***Every luminaire will have an integral driver.

Package Contents• Luminaire

1. LUMINAIRE

6”

2’, 3’, 4’, 5’, 6’, 7’, 8’

Wall Mount Fixture

Single Gang Junction BoxMounted Horizontally

Fixture Mounting Plate

Power Side

Non-Power Side

6”

Rough-in electrical adhering to local codes. Install mounting plates to structure / blocking as shown.

Remove Phillips head retaing screw and teflon washer from mounting plate. Set aside.

Remove mounting plates from each end of fixture.

21

3

inStaLLing an individuaL or row Starter Luminaire

Page 3: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 3

Individual Starter

Secure mounting plates to blocking as shown.

Power Side

Non-Power Side

Connect wires per local electrical code.

54

Hang fixture on to the backplate by inserting the two tabs into the slots on the top of the backplate.

Secure fixture to wall by replacing the Phiilips screw and teflon washer from step 1.

6 7

inStaLLing an individuaL or row Starter Luminaire

Page 4: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 4

Starter Mid End

Power Side Power Side Power SideNon-Power Side Non-Power Side Non-Power Side

Non-Power Side

Step 2Step 1 Step 3

*Each fixture has two mounting plate located equal distance from each end regardless of fixture length.

inStaLLing a row-mid or row-end

Repeat steps 1, 2, 3, 4, 6, & 7 from pages 2 and 3 to install the next fixture in the row.

Page 5: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 5

After the“starter” or “mid” is fully secured to the wall, then make power connection and mount the next luminaire, then join them together as shown below and secure with two torsion spring latches that are integrated into the luminaire.

12 13

SNAP!

Connect the strap to the hole in the catch tray. Collapse the alignment strap back to its original position to lock the two fixtures together.

1110

Insert alignment tabs from the next fixture into the slots on the current fixture.

Release the alignment strap from the current fixture and extend the catch tray from the next fixture.

8 9

Dislodge the lens/LED board assembly from the bottom of the luminaire and let it hang by the support chains.

Connect male electrical connector from next fixture to female connector on the current fixture.

inStaLLing a row-mid or row-end (after Starter haS been inStaLLed, Step 1, 2, 3, 4, 5, 7 from page 2 and 3)

Page 6: Installation Instructions Regolo R14 all ount V /Indirect ... · Installation Instructions Regolo R14 all ount V /Indirect, D/Direct, /i-Di rect heet Rock urface ount NULITE Lighting

Installation InstructionsRegolo RW14 Wall Mount

V/Indirect, D/Direct, B/Bi-DirectSheet Rock Surface Mount

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com March 2019 Page 6

14 15

Replace the lens/LED board assembly from the bottom of the luminaire. Repeat for all fixtures in the row.

inStaLLing a row-mid or row-end (after Starter haS been inStaLLed, Step 1, 2, 3, 4, 5, 7 from page 2 and 3)