Installation Instructions PFACV2 Picture Frame Adaptor / Decorative Cover For fitting the Unity CV2GIP to either 150mm or 100mm duct openings To convert a 150mm hole to 100mm or ‘make good’ installations when replacing an existing square 100mm fan. PFACV2 Unity CV2GIP 05.10.670 Issue 1 April 2012 Greenwood Air Management Ltd Greenwood House, Brookside Avenue, Rustington, West Sussex, BN16 3LF Tel: +44 (0) 1903 771021 Fax: +44 (0) 1903 782398 Web: www.greenwood.co.uk Email: [email protected] 2 3 4 6 Using a small flat blade screwdriver, prise out the four fixing screw caps. Ensure the orientation of the PFACV2 has been considered before completing the next stage. With foam seal facing the wall fix PFACV2 (using outer fixing points) with supplied four ‘long screws’ and rawl plugs. For wall installations ensure the wiring notch in the PFACV2 faces uppermost and to the right-hand side. Cover outer fixing points by clipping in the screw caps. Pass electric supply cable through the PFACV2 and fan body and offer fan into the opening. Ensure the wiring notch in the decorative cover faces uppermost and to the right-hand side. This will ensure the IPX4 of the product. Carefully close electronics cover with outer rubber seal edges correctly positioned into the fan body. Fully tighten fixing screws until locked, attach outer front cover. Fix fan and decorative cover with the four ‘short screws’ provided within the loose item set and level off. Wire the fan (see installation instructions supplied with the Unity CV2GIP). 1 Safely isolate old fan from electrical supply, remove and discard responsibly. Prepare opening and surface to take the PFACV2. 5 Screw caps PFACV2 Fixing points Electronics cover Outer front cover

Upload: others

Post on 12-Oct-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation Instructions... · Installation Instructions PFACV2 Picture Frame Adaptor / Decorative Cover For fitting the Unity CV2GIP to either 150mm or 100mm duct openings To convert

Installation InstructionsPFACV2 Picture Frame Adaptor / Decorative Cover

For fitting the Unity CV2GIP to either 150mm or 100mm

duct openings

To convert a 150mm hole to 100mm or ‘make good’ installations when

replacing an existing square 100mm fan.

PFACV2 Unity CV2GIP

05.10.670 Issue 1 April 2012

Greenwood Air Management LtdGreenwood House, Brookside Avenue, Rustington, West Sussex, BN16 3LFTel: +44 (0) 1903 771021 Fax: +44 (0) 1903 782398Web: www.greenwood.co.uk Email: [email protected]

2 3

4 6

Using a small flat blade screwdriver, prise out the fourfixing screw caps. Ensure the orientation of the PFACV2has been considered before completing the next stage.

With foam seal facing the wall fix PFACV2 (using outerfixing points) with supplied four ‘long screws’ and rawlplugs. For wall installations ensure the wiring notch inthe PFACV2 faces uppermost and to the right-hand side.Cover outer fixing points by clipping in the screw caps.

Pass electric supply cable through the PFACV2 and fanbody and offer fan into the opening. Ensure the wiringnotch in the decorative cover faces uppermost and to theright-hand side. This will ensure the IPX4 of the product.

Carefully close electronics cover with outer rubber sealedges correctly positioned into the fan body. Fully tightenfixing screws until locked, attach outer front cover.

Fix fan and decorative cover with the four ‘short screws’provided within the loose item set and level off. Wire thefan (see installation instructions supplied with the UnityCV2GIP).

1

Safely isolate old fan from electrical supply, remove anddiscard responsibly. Prepare opening and surface to takethe PFACV2.

5

Screw caps

PFACV2Fixingpoints

Electronics cover

Outerfrontcover