"A" 2.0" 3.0" 4.0" .500 .500 .500 .500 FINISHED EDGE WITH J-ANGLE 1.5" 2.5" 3.5" NOTES: 1. LEAVE PROTECTIVE WRAPPING ON FIXTURES UNTIL READY TO BEGIN INSTALLATION. 2. FIXTURES ARE PROVIDED WITH BRANCH CIRCUIT WIRING. 3. DRYWALL INTERFACE DESIGNED AROUND A THEORETICAL DRYWALL THICKNESS OF 1/2" FIELD CONDITIONS MY VARY. 4. LUMINAIRE INSTALLATION MUST HAPPEN PRIOR TO CEILING INSTALL. 0" REGRESS 2" REGRESS 3" REGRESS 4" REGRESS T-GRID DRYWALL FIXTURE DIM "A" 2L 2" 3L 3" 4L 4.25" 6L 6" litecontrol.com DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100 INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER / WALL SLOT MOUNTING TYPE: DRYWALL OR T GRID REV:1 DATE: 3/21/19 PAGE: 1 OF 6 SUPPLIED BY INSTALLER TOOLS REQUIRED DRAWING: 510690 DRILL/SCREWDRIVER TIN SNIPS OR SAW (TO CUT SHEET METAL) CHALK LINE 1/4" SOCKET OR WRENCH SNAP IN CONDUIT DRYWALL SCREWS

Upload: others

Post on 02-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

"A"

2.0" 3.0"

4.0"

.500

.500 .500

.500

FINISHED EDGE WITH J-ANGLE

1.5" 2.5"

3.5"

NOTES:1. LEAVE PROTECTIVE WRAPPING ON FIXTURES UNTIL READY TO BEGIN INSTALLATION.2. FIXTURES ARE PROVIDED WITH BRANCH CIRCUIT WIRING.3. DRYWALL INTERFACE DESIGNED AROUND A THEORETICAL DRYWALL THICKNESS OF 1/2" FIELD CONDITIONS MY VARY.4. LUMINAIRE INSTALLATION MUST HAPPEN PRIOR TO CEILING INSTALL.

0" REGRESS 2" REGRESS 3" REGRESS 4" REGRESS

T-GRID

DRYWALL

FIXTURE DIM "A"2L 2"3L 3"4L 4.25"6L 6"

litecontrol.com

DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER / WALL SLOT MOUNTING TYPE: DRYWALL OR T GRID

REV:1 DATE: 3/21/19

PAGE: 1 OF 6

SUPPLIED BY INSTALLERTOOLS REQUIRED

DRAWING: 510690

DRILL/SCREWDRIVERTIN SNIPS OR SAW (TO CUT SHEET METAL)CHALK LINE1/4" SOCKET OR WRENCH

SNAP IN CONDUITDRYWALL SCREWS

Page 2: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

B

USING DIMENSION "C" AS A REFERENCE TO FINISHED CEILING HEIGHT, SNAP A LEVEL CHALK LINE ON WALL FOR POSITIONING OF SUPPORT RAILS. PLACE BOTTOM EDGE OF SUPPORT RAILS ON CHALK LINE AND SECURE TO THE WALL WITH DRYWALL SCREWS.

NOTE: LAST SECTION(S) OF SUPPORT RAILS MAY NEED TO BE FIELD CUT.

CHALK LINE

T-BAR CENTER(FOR GRID OPTION)

"C" CEILING OPENING(DRYWALL)

WALL REF

SUPPORT RAIL

TO ENSURE SUPPORT RAILS MAINTAIN ALIGNMENT, INSERT SPLINE KEYS BETWEEN RAIL ENDS AS EACH LENGTH IS ADDED. SHIM BEHIND SUPPORT RAILS WHEN NECESSARY TO FORM A CONTINUOUS STRAIGHT RAIL. BUTT RAIL TO RAIL CORNERS THEN CONTINUE ONTO FIXTURE INSTALLATION.

DIMENSION "C" TABLE DICTATES DISTANCE FROM BOTTOM OF SUPPORT RAIL TO BOTTOM OF PLENUM PLATE.

PEEL OFF ADHESIVE BACKING ON BOTTOM OF SPLINE RUNNERS AND ATTACH TO TOP SURFACE OF DRYWALL, FLUSH WITH FINISHED EDGE. SPLINE RUNNERS ARE SHIPPED IN 48" LENGTHS; FIELD CUT ANY END PIECES NECESSARY TO FIT FULL LENGTH OF CEILING.

SPLINE KEY

FIXTURE SERIES CEILING OPENING (DRYWALL)

T-BAR CENTERS(9/16" OR 15/16" GRID)

2L 2-1/2" 3"3L 3-1/2" 4"4L 4-5/8" 5-1/8"6L 6-5/8" 7-1/8"

SUPPORT RAIL HEIGHTDIMENSION "C" (support rail to finished ceiling)

2L 3L/4L/6LDRYWALL T-GRID DRYWALL T-GRID

0" REGRESS 0.67" 1.17" 2.43" 2.93"2" REGRESS 2.67" 3.17" 4.43" 4.93"3" REGRESS 3.67" 4.17" 5.43" 5.93"4" REGRESS 4.67" 5.17" 6.43" 6.93"

litecontrol.com

DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER / WALL SLOT MOUNTING TYPE: DRYWALL OR T GRID PAGE: 2 OF 6

DRAWING: 510690

SUPPORT RAIL INSTALLATIONSUPPORT RAIL(S) MUST BE INSTALLED PRIOR TO INSTALLATION OF FIXTURE(S).

REV:1 DATE: 3/21/19

Page 3: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

5

STARTING IN THE MIDDLE OF THE ROW, RAISE FIXTURE AND HANG ON SUPPORT RAIL.

AA

PLENUM PLATE

FIXTURE HOUSING

ATTACH PLENUM PLATE TO FIXURE HOUSING USING #8 SHEET METAL SCREWS @ APPRX. 2' INTERVALS. BE SURE TO USE CORRECT HOLES ON HOUSING FOR SPECIFIC APPLICATION.

D

REMOVE REFLECTOR ASSEMBLY BY REMOVING 4 #8 SHEET METAL SCREWS.

E

REMOVE ACCESS COVER AND ONE KNOCKOUT, MAKE ALL WIRING CONNECTIONS INSIDE FIXTURE. REPLACE ACCESS COVER.

HH

J

SECTION H-H

U

1/4-20 NUT

1/4-20 SCREW

DETAIL AASCALE 1 : 4

TOP HOLES(T-GRID)

BOTTOM HOLES(DRYWALL)

AB

SAFTEY WIRE

FF

G

SECURE FIXTURE BY ADJUSTING LEVELING SCREWS AND ATTACHING SAFTEY WIRE.A 1/4" SOCKET WRENCH OR RATCHET WRENCH MAY BE REQUIRED TO FASTEN LOCKING SCREWS DEPENDING ON FIXTURE SIZE.FOR ROW MOUNTED FIXTURES, PROCEED TO STEP 5a

8-32 LEVELING/LOCKING SCREW

NOTE: TOP HOLES ON PLENUM PLATE ARE USED FOR T-GRID, BOTTOM HOLES ARE USED FOR DRYWALL.

MAKE BRANCH WIRE CIRCUIT CONNECTIONS FROM FIXTURE TO FIXTURE.

!!! FIXTURE(S) MUST BE INSTALLED PRIOR TO INSTALLATION OF CEILING. !!!FIXTURE INSTALLATION

1 2 3

4 5a

AT ROW JOINT SEAMS, SECURE FIXTURES TOGETHER USING (2) 1/4-20 MACHINE SCREWS, (2) NUTS AND SAFTEY WIRE

litecontrol.com

DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER / WALL SLOT MOUNTING TYPE: DRYWALL OR T GRID PAGE: 3 OF 6

DRAWING: 510690REV:1 DATE: 3/21/19

Page 4: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

6

REATTACH ALL LED REFLECTOR MODULE ASSEMBLIES. FOR ROW, ATTACH ROW JOINT COVERS (SHIPPED SEPARATELY) BY SNAPPING THEM INTO ADJACENT LED REFLECTORS. CLEAN FIXTURE EXTERIORS USING GENERAL WINDOW CLEANER.

LED REFLECTOR MODULES(FIXTURE HOUSINGS HIDDEN)

JOINT COVER

FOR INDIVIDUAL FIXTURES, INSTALL REFLECTOR MODULE, END CAPS AND LENS. REFER TO INSTALL INSTRUCTION 510647 FOR PROPER LENS INSTALLATION AND ORIENTATION.

FOR ALL FIXTURES WITH STRAIGHT EXTENSIONS OR CORNERS, SKIP TO STRAIGHT EXTENSION INSTALLATION ON PAGE 5

5b

litecontrol.com

DO NOT MODIFY OR ALTHER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER MOUNTING TYPE: PAGE: 4 OF 6

DRAWING: 510690REV:1 DATE: 3/21/19

Page 5: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

1a 2a

3a 4a

N

SECURE END CAPS TO FIXTURE USING 2 #8 SHEET METAL SCREWS.

FIELD CUT PLENUM PLATE TO REQUIRED LENGTH TO REACH WALL, OR OTHER STRAIGHT EXTENSION.

END OF FIXTURE TO WALL DIMENSION

FOR ALL CORNERS, BE SURE TO CUT PLATES SO THEY WILL BUTT UP AGAINST THE ADJOINING PLENUM PLATE.

R

T

12

RAISE COVER RAIL UP TO PLENUM PLATE AND SECURE WITH 2 TINNERMAN CLIPS.

IF COVER RAIL IS TOO LONG, IT MAY BE TUCKED INTO PLENUM PLATE.

.250

.375

DIM "A"

STRAIGHT EXTENSION INSTALLATION

SHIELD HEIGHT TABLE

2" REG T-GRID 1.89"DRYWALL 1.39"

3" REG T-GRID 2.39"DRYWALL 2.89"

4" REG T-GRID 3.39"DRYWALL 3.89"

litecontrol.com

DO NOT MODIFY OR ALTER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER / WALL SLOT MOUNTING TYPE: DRYWALL OR T GRID PAGE: 5 OF 6

DRAWING: 510690REV:1 DATE: 3/21/19

Page 6: INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD … · 2019-03-21 · drywall 1.39" 3" reg t-grid 2.39" drywall 2.89" 4" reg t-grid 3.39" drywall 3.89" litecontrol.com do not modify

SNAP T-BAR CLIPS OVER T-BARS SUCH THAT THEY ENGAGE BOTTOM HEM OF FIXTURE. TWO CLIPS ARE REQUIRED FOR 24", 36", AND 48" FIXTURES; THREE CLIPS ARE REQUIRED FOR 72" AND 96" FIXTURES.

PEEL OFF ADHESIVE BACKING ON BOTTOM OF SPLINE RUNNERS AND ATTACH TO TOP SURFACE OF DRYWALL, FLUSH WITH FINISHED EDGE. SPLINE RUNNERS ARE SHIPPED IN 48" LENGTHS; FIELD CUT ANY END PIECES NECESSARY TO FIT FULL LENGTH OF CEILING.

CEILING INSTALLATION GUIDLINES!!! FIXTURE(S) MUST BE INSTALLED PRIOR TO INSTALLATION OF CEILING. !!!

litecontrol.com

DO NOT MODIFY OR ALTHER THIS PRODUCT IN ANY WAY, OR INSTALL IN ANY FASHION WHICH IS CONTRARY TO THE INSTRUCTIONS CONTAINED HEREIN. IF YOU HAVE ANY QUESTIONS REGARDING THIS PRODUCT OR THE INSTALLATION OF IT, PLEASE CALL LITECONTROL ENGINEERING AT 781-294-0100

INSTALLATION INSTRUCTIONS FIXTURE SERIES: MOD PERIMETER MOUNTING TYPE: PAGE: 6 OF 6