installation instructions - american water

5
Installation Instructions PP-AS20 Anti-Scale System

Upload: others

Post on 09-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Installation InstructionsPP-AS20 Anti-Scale System

Precautions • Readallprecautions,installation,andoperatinginstructionscarefully

andcompletelybeforeinstallingunit.

• DonotdiscardOwner’sManual.

• Installinaccordancewithallstateandlocalplumbingcodes.

• Donotinstallwherelinepressuremayexceed100psi. Operatingpressurerangeis20-100psi.

• Installoncoldwaterlinesonly.Protectunitfromfreezing. Operatingtemperaturerangeis40-100°F.

• Installunitinavertical,upright,andlevelposition.

• Donotuseliquidcompoundsforconnection. Onlyuseplumber’stapeforconnections.

• Allowaminimumof3"underthesystemforcartridgereplacements.

• Donotovertightenfittings.

21¼"

25¼"

3¼"

INLET

OUTLET

25⁄16"

51⁄8"21⁄4"

51⁄2"PP-AS20 Specifications

ConnectionSize 3/4” NPT

MaximumFlow 7gpm

MinimumPressure 20psi

MaximumPressure 100psi

MinimumTemperature 40°F

MaximumTemperature100°F

MaximumHardness 45gpg

MaximumChlorine 2.0ppm

Install on cold water lines only

COMPONENTS •PP-AS20FilterHousing•PP-AS20RFilterCartridge•InstallationInstructions•(1)Wrench•(1)Bracket

THIS UNIT MUST BE INSTALLED BY A LICENSED PLUMBER TO VALIDATE THE WARRANTY.

Installation 1. Consultandfollowallapplicablestateandlocalplumbingcodes.

2. TurnoffallequipmenttobefedbythePP-AS20.

3. LocateWatersupplyshutoffvalveandturnoff.

4. Locatesuitablelocationforinstallation.

5. Mountunittowallwithincludedmountingbracket.(Ensurewallmaterialisstableenoughformountingpurposes.)

6. Runasuitablelinefromtheincomingcoldwaterlinetotheinlet(left)sideoftheleftsideoftheProductPreserverssystem. NOTE: Do not over tighten connection fittings. Do not use pipe dope. Do not use more than seven layers of plumber’s tape.

7. Abypasslineisrecommendedtobeinstalled.(Notincluded)

8. SelectasuitablesizetubingtorunfromtheProductPreserversoutlettothetanklesswaterheater.Adrainvalve(notincluded)isrecommendedtobeinstalledafterthefilterforflushingandfiltercartridgechanges. NOTE: If not installing a drain valve, do not connect the tubing to the tankless water heater at this time. This line will be used to flush the system.

9. Oncesystemisinstalledslowlyapplypressurebyslightlyopeningfeedwatervalve. Ifdrainvalveisinstalled,openvalvetopurgeanyairthatisintheline.

10. Aftersystemhasfullypressurizedinspectforanyleaks.

11.Flushsystembyopeningdrainlinevalve.Ifnovalvewasinstalled,flushBEFOREconnectinglinetothetanklesswaterheater.Flushfor2minutes.

12. Ifthereisnotapressurereliefvalveinstalledonthetanklesswaterheaterhotwateroutlet,installabrassteeonthetanklessoutlet.Installapressurereliefvalvetoonesideofthetee.Connectthehotwaterlinetotheothersideofthetee.

13. Noteinstallationdateforreplacementelementscheduling.Changethefiltercartridgeatleastonceeverytwoyears.

Y

Installation Recirculation System

Installation BasicwithBypassLoopandOptionalPP-PRE-AS20Pre-Filter

Important:Do not over tighten fittings as this may cause leakage and broken fittings. Do NOT use pipe dope. The use of pipe dope voids the warranty. You may use plumber’s tape. Leave two-three threads exposed and do not exceed seven layers of plumber’s tape. More than seven layers will cause the nipple to crack and leak.

Date Service Performed Initial

PP-AS20 Maintenance History

CONDITIONS1.TheProductPreservers®systemmustbeinstalledinapplicationswithmunicipallysuppliedwateradheringtoEPAguidelines.2.Anycomponentfailuremustnotresultfromabuse,fire,freezingorotheractsofnature,violence,orimproperinstallation.3.Equipmentmustbeinstalledandoperatedincompliancewiththelocalplumbingcodesandonanapprovedwatersupply.4.Equipmentislimitedtouseatwaterpressuresandtemperaturesthatdonotexceedourpublishedspecifications.5.Watersupplymustnotexceed2.0PPMchlorine.Forwatersupplyexceeding2.0PPMchlorine,pretreatmentisrequired.

(Pleasecontactyourwatertreatmentspecialist.)6.Information,includingmodelnumber,serialnumber,anddateofinstallation,mustbeprovidedforanyclaimspertainingto

equipmentinwarranty.7.Defectivepartsaresubjecttoinspectionbythecompanyoranyauthorizedrepresentativebeforefinalcommitmentofwarranty

adjustmentismade.8.Thecompanyreservestherighttomakechangesorsubstitutionsinpartsorequipmentwithmaterialofequalqualityorvalue

andofthencurrentproduction.

LIMITATIONSOurobligationunderthiswarrantywithrespecttothetankorvalveislimitedtofurnishingareplacementfor,oratouroption, repairinganypartorpartstooursatisfactionthatprovedefectivewithinthewarrantyperiodstatedonthebackcover.SuchreplacementpartswillbedeliveredtotheownerF.O.B.nearestfactory,atnocost,excludingfreightandlocallaborcharges,ifany.OurobligationunderthiswarrantywithrespecttotheProductPreservers®mediawillbelimitedtofurnishingareplacementforthemediawithintwoyearsfromdateoforiginalinstallation.SuchreplacementmediawillbedeliveredtotheownerF.O.B.nearestfactory,atnocost,excludingfreightandlocallaborcharges,ifany.Damagetothemediaduetochlorine,otheroxidizersorfoulingcausedbylocalwaterconditionsoranyotheroperationoutsideofthelimitsshownunderSpecifications,isnotcoveredbythiswarranty.THEWARRANTYSETFORTHHEREINISGIVENEXPRESSLYANDISTHEONLYWARRANTYGIVENBYA.O.SMITHWATERHEATERSWITHRESPECTTOTHEPRODUCT.A.O.SMITHWATERHEATERSMAKESNOOTHERWARRANTIES,EXPRESS ORIMPLIED.A.O.SMITHWATERHEATERSHEREBYSPECIFICALLYDISCLAIMSALLOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDINGBUTNOTLIMITEDTOTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFOR APARTICULARPURPOSE.Theremedydescribedunderthiswarrantyshallconstitutethesoleandexclusiveremedyforbreachofwarranty,andthecompanyshallnotberesponsibleforanyincidental,specialorconsequentialdamages,includingwithoutlimitation,freight,handling,lostprofitsorthecostofrepairingorreplacingotherpropertywhichisdamagedifthisproductdoesnotworkproperly,othercostsresultingfromlaborcharges,delays,vandalism,negligence,foulingcausedbyforeignmaterial,damagefromadversewaterconditions,chemical,oranyothercircumstancesoverwhichthecompanyhasnocontrol.Thiswarrantyshallbeinvalidatedbyanyabuse,misuse,misapplicationorimproperinstallationoftheproduct.Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,andsomestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages.Thereforetheabovelimitationsmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrights,andyoumayhaveotherrightsthatvaryfromstatetostate.Youshouldconsultapplicablestatelawstodetermineyourrights.SOFARASISCONSISTENTWITHAPPLICABLESTATELAW,ANYIMPLIEDWARRANTIESTHATMAYNOTBEDISCLAIMED,INCLUDINGTHEIMPLIEDWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE,ARELIMITEDINDURATIONTOTHEAPPLICABLEWARRANTYPERIODSSTATEDONBACKCOVER.

CUT HERE AND ATTACH TO SYSTEM

CHANGETHEFILTERCARTRIDGEATLEASTONCEEVERYTWOYEARS.PP-AS20 Replacement Instructions 1. DetermineifequipmentconnectedtoyourProduct

PreserversSystemmustbeturnedoffbeforeshuttingoffwater.

2. Ifbypasslineisinstalled,bypasssystemduringfilterchange.Openbypassvalve,closeunitinletvalve,andcloseunitoutletvalve.Figure A

3. Ifnobypasslineisinstalled,turnofffeedwater.

4. Releasepressuretosystembypressingredbutton ontopofunit.Figure B

5. Unscrewhousingsumpusingincludedwrenchifnecessary.Figure C

6. Discardoldcartridge.Retainspacer.Figure D

7. Insertnewcartridgeintosump.Re-usethespacerthatwasincludedwiththeoriginalunit.Figure D

8. InspectO-ringforanydamageandreplaceifnecessary.Figure E

9. Re-installfilterhousingsump.HANDTIGHTENONLY.

10. Pressurizesystembyslightlyopeningfeedvalve.Oncepressurized,openvalvefully.Inspectsealsforanyleaks.Ifthereisaleak,youmaytightenthesumpslightlymorewiththewrench.

11. Flushsystemfor2minuteswithdrainvalveopen.Ifnodrainvalveisinstalleddisconnectfromequipmentforflushcycle.

12. Turnonallequipmentconnectedtosystem.

13. Recordfilterchangedateforreplacementelementscheduling.

OFF OFF

ONA

B

C DE

Limited Warranty CompanywarrantsitsProductPreservers®Anti-ScaleSystemasfollows:

•TheProductPreservers®cartridgesystemiswarrantedtobefreeofdefectsinmaterialsandworkmanshipfortwoyearsfromthedateoforiginalshipment.

•ProductPreservers®filtercartridgesarewarrantedforperformanceforaperiodoftwoyearsfromthedateoforiginalinstallationwheninstalledandoperatedinaccordancewiththeinstructionsinthecorrespondingInstallationandOperationManual.

This product is not intended for use with water that is microbiologically unsafe or of unknown quality without

adequate disinfection before or after the unit.

ppas20_install_20190123

ProductPreservers® Anti-Scale System500TennesseeWaltzParkwayAshlandCity,TN37015