installation guide for ac-1000rf & sa v1.6 installation guide for ac-1000rf & sa v1.6...

17
Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd.

Upload: hugo-montgomery

Post on 20-Jan-2016

238 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

Installation Guide forAC-1000RF & SA V1.6

Installation Guide forAC-1000RF & SA V1.6

Version Eng1.10

Jul.,25.2012

Union Community Co., Ltd.

Page 2: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

2

Wiegand, RS232 & RS485 Interface

TCP/IP Network Interface (RJ45)

DC Power Input Interface

Door Lock & Status Input Interface

FGND (Green) - 3Ground (Black) - 2+12~+24V (Red) - 1

P - 3P - 2P - 1

Ground (Black) - 8Door_Monitor2 (Blue) - 7Door_Monitor1 (Green) - 6Door_Monitor0 (Yellow) - 5Inside_Open (Orange) - 4Lock Ground (Black) - 3Door Lock2 (Red) - 2Door Lock1 (Brown) - 1

P - 8P - 7P - 6P - 5P - 4P - 3 P - 2P - 1

RS485A (Green) - 1RS485B (Blue) - 2Ground (Black) - 3

Data0 (Orange) - 1Data1 (Yellow) - 2Ground (Black) - 3

Data2 (Brown) - 1Data3 (Red) - 2Ground (Black) - 3

RS232_TXD (Violet) - 2RS232_RXD (Gray) - 3RS232_GND (Black) - 4

Wiegand In

Wiegand Out

RS485

RS232

1. External Connectors

** PIN 1 is N.C

Page 3: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

3

F201 : Fuse

Volume Control

Lock Type Select S/W

J201 : DC Input J301 : LAN Interface

J121 : RS-485 Interface

J102 : Wiegand Out

J151 : Lock Interface

J101 : Wiegand In

Lock Type Select S/W

2. Main board feature

J120 : RS232

SW120 : RS-485 termination resistor ON/OFF

SW101: RS232 (TTL/232 level select)

Page 4: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

4

Special. HiD Module to Wiegand Input interface

iClass

White

RED

Green

Black

Ground (Black) - 3Data3 (Red) - 2Data2 (Brown) - 1

Wiegand In (J101)

GND (Black) - 4NC - 3NC - 2

5V Vcc (Red) - 1

RS232 Debug (J120)

* 1 .Insert into the Harness side prior to soldering with 5pcs ready for contraction tube 3pie 10mm.2 . Connecting with soldering to match the colors as shown in the figure. (Black is connected as Wire 3 )3 . The column to shrink to fit the soldering site of contraction Tube after soldering .4 . Short does not occur to the part to remove the Wire the rest of the iClass, deleted I Taping processing so

as not .5 . When you are finished , open the case of AC1000, to be inserted in each of J101, J120 of Page 3.6 . After connecting the power Close the Case, you can adjust the settings in the configuration Wiegand IN .* To use the RS232 Cable of Page2, and minus the Violet of Pin 2When installed toward the Pin1, it is possible to use as a power source . By replacing the orange line in the

figure aboveIt is possible to use .* It can be used together HiD Card and Card of the existing AC1000 , the thickness of the product is onPre-installation check is necessary because it may affect the distance 

Page 5: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

5

LockCon2

D151

M4

AK

PV151VN20-260L-751JT

12

Motor/Strike

LockCon2

5V

AutoDoorSW154DJMM-12V

13

2

R165102R1 2LockCon1

R167102R1 2

D154M4

AK

LockCon1

Strike

LM_COM1

Door_Lock2

K152G6S-2-5VDC

910

8

43

51

12

LockCon1 Q151

KN2222AS

B

EC

PV154VN20-260LJ

12

R168473R

1 2

PV153VN20-260L-751JT

12

LockCon1

MotorLM_NO

LockCon2

LM_COM1

D153

M4

AK

VIN

NO

LockCon1

Door_Lock1LM_NC

LockCon1

LM_NO

NC

ST/M

LM_COM1

VIN

LM_NO

Q152

KN2222AS

B

EC

Auto Door SW153DJMM-12V

13

2LM_NO

DC157

104C2

12

DC156

104C21

2

PV152VN20-260LJ

12

LockCon2

SW151DJMM-12V

13

2

D152M4

AK

Strike/MT

R166473R

1 2

5V

SW152DJMM-12V

13

2

K151G6S-2-5VDC

910

8

43

51

12

ST/M

3. Schematic for Door Lock Interface

Page 6: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

6

ON

WnP1 2 3 4

- C +

(-)Black

(+)Red

Door Monitor

Lock(+)

Pin 1

Pin 5

Pin 8

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Pin 4

Pin 3

Lock(-)

Ground (-)Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground

4. Connecting Dead-Bolt Type Door Lock ( Fail Safe )4. 1. Connect with one system & one lock

(Brown) - 1 (Red) - 2

(Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7

(Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

◈ Lock Type Select Switch

◈ Wiring diagram

Inside Door Open S/W

Page 7: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

7

ON

WnP1 2 3 4

- C +

(-)Black

(+)Red

◈ Lock Type Select Switch

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

System 2

◈ Wiring diagram

Pin

1

Pin

1

Pin

5

Pin

5

System 1

Lock (+)

Lock (-)Door Monitor

System 1

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

System 2

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Pin

3

Pin

2

Pin

8

4. Connecting Dead-Bolt Type Door Lock ( Fail Safe )4. 2. Connect with two system & one lock

Page 8: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

8

(-)Black

(+)Red

Door Monitor

Lock(+)Pin1

Pin 5

Pin 8

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Pin 4

Pin 3

Lock(-)

GroundDoor Lock1 Door Lock2Lock GroundInside_OpenDoor_Monitor0Door_Monitor1Door_Monitor2Ground

5. Connecting Strike Type Door Lock ( Fail Safe )

(Brown) - 1(Red) - 2

(Black) - 3 (Orange) - 4

(Yellow) - 5 (Green) - 6 (Blue) - 7

(Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

5. 1. Connect with one system & one lock

◈ Lock Type Select Switch

◈ Wiring diagram

Inside Door Open S/W

Page 9: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

9

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

System 2

Pin

1

Pin

1

Pin

3

Pin

3P

in2

Pin

5

Pin

5

System 1

Lock (+)

Lock (-)Door Monitor

System 1

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

System 2

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Pin

8

◈ Lock Type Select Switch

◈ Wiring diagram

5. 2. Connect with two system & one lock

5. Connecting Strike Type Door Lock ( Fail Safe )

Page 10: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

10

(-)Black

(+)Red

Door Monitor

Lock(+)Pin1

Pin 5

Pin 8

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Pin 4

Pin 3

Lock(-)

GroundDoor Lock1 Door Lock2Lock GroundInside_OpenDoor_Monitor0Door_Monitor1Door_Monitor2Ground

6. Connecting Strike Type Door Lock ( Fail Secure )

(Brown) - 1(Red) - 2

(Black) - 3 (Orange) - 4

(Yellow) - 5 (Green) - 6 (Blue) - 7

(Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

◈ Lock Type Select Switch

◈ Wiring diagram

6. 1. Connect with one system & one lock

Inside Door Open S/W

Page 11: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

11

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

System 2

Pin

1

Pin

1

Pin

3

Pin

3

Pin

5

Pin

5

System 1

Lock (+)

Lock (-)Door Monitor

System 1

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

System 2

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

◈ Lock Type Select Switch

◈ Wiring diagram

6. 2. Connect with two system & one lock

6. Connecting Strike Type Door Lock ( Fail Secure )

Page 12: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

12

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Lock(+)

Door Monitor

Lock(-)

Pin 1 Lock(+)

Brown (+)

Pin 8

Pin 5

Pin 3 GroundPin 4 Inside_Open

Door Lock1Door Lock2 Lock GroundInside_OpenDoor_Monitor0Door_Monitor1Door_Monitor2Ground

7. Connecting EM Type Door Lock ( Fail Safe )

Pin 1(Brown) - 1

(Red) - 2(Black) - 3

(Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

◈ Lock Type Select Switch

◈ Wiring diagram

7. 1. Connect with one system & one lock

Inside Door Open S/W

Page 13: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

13

7. Connecting EM Type Door Lock ( Fail Safe )7. 2. Connect with one system & two lock ** Use external DC Power Adapter

- (Black)

+ (Red)

Door Monitor

Lock 1

Lock 2

Pin

1Pin

2

Pin

4

12V 3AAdapter

(+)

(-)

Lock(+)

Lock(-)

Inside Door Open S/W

Input1

GND

Exit B

Pin

5

Pin

8

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

◈ Lock Type Select Switch

◈ Wiring diagram

Page 14: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

14

Auto Door Operating Part Auto Door Motor

Sensor Input Line

9P CONN

Auto-Door Sensor Auto-Door Monitor

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Inside Door Open S/W

8. Connecting Auto Door ( Contact Control )

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Lock 1Pin 1

Lock 2Pin 2

◈ Lock Type Select Switch

◈ Wiring diagram

8. 1. Connect with two system & one door

Lock(+)

Door Lock1Door Lock2 Lock GroundInside_OpenDoor_Monitor0Door_Monitor1Door_Monitor2Ground

(Brown) - 1(Red) - 2

(Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7 (Black) - 8

Page 15: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

15

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

System 2

Pin

1

Pin

1

Pin

3

Pin

2

System 1

System 1

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

System 2

(Bro

wn)

- 1

(Red

)

- 2

(Bla

ck)

-

3 (

Ora

nge)

- 4

(Y

ello

w)

- 5

(G

reen

) -

6 (

Blu

e)

- 7

(B

lack

) -

8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Auto Door Operating Part Auto Door Motor

Sensor Input Line

9P CONN

Auto-Door Monitor

◈ Lock Type Select Switch

◈ Wiring diagram

8. 2. Connect with two system & one door

8. Connecting Auto Door ( Contact Control )

Page 16: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

16

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Lock(+)Pin 1

Pin 5Pin 6

Pin 4Pin 3Pin 2 Lock(-)

Ground

Door MonitorOpen MonitorClose MonitorPin 7

Door Lock1 Door Lock2Lock GroundInside_OpenDoor_Monitor0Door_Monitor1Door_Monitor2Ground

9. Connecting Motor Lock

(Brown) - 1(Red) - 2

(Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6

(Blue) - 7 (Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Pin 8

Inside Open

◈ Lock Type Select Switch

◈ Wiring diagram

Inside Door Open S/W

Page 17: Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul.,25.2012 Union Community Co., Ltd

17

12 V (+)

Pin 1

Pin 8

ON

1 2 3 4 5 6

1) SW2

2) SW151~SW154

Pin 3

Door Lock1 Door Lock2 Lock Ground Inside_Open Door_Monitor0 Door_Monitor1 Door_Monitor2 Ground

10. Connecting 2 Emergency Lamps

(Brown) - 1 (Red) - 2

(Black) - 3 (Orange) - 4 (Yellow) - 5 (Green) - 6 (Blue) - 7

(Black) - 8

SW151

SW152

SW153

SW154

NC

NO/Motor

Strike/MT

AutoDoor

Strike/MT

AutoDoor

Strike

Motor

Ground (-) Ground (-)12 V (+)

Pin 2

Emergency

Lamp 1

Emergency

Lamp 2

◈ Lock Type Select Switch

◈ Wiring diagram