installation and operation manual€¦ ·  · 2017-02-20installation and operation manual brc1e53...

2
Installation and operation manual BRC1E53 1 3P419248-1-KA – 2015.09 The English text is the original instruction. Other languages are translations of the original instructions. Refer to http://www.daikineurope.com/support-and-manuals/ product-information/ for more detailed user reference guides. Installation: see page 2. 1. General safety precautions Please read these "1. General safety precautions" carefully before installing air conditioning equipment and be sure to install it correctly. Failure to follow these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. 2. Features and functions The BRC1E53 is a state of the art remote controller that offers full control over your installation. 1 BASIC REMOTE CONTROLLER The basic remote controller functions are: ON/OFF, operation mode change-over, temperature adjustment, air volume adjustment, airflow direction adjustment. 2 CLOCK FUNCTION The clock functions are: 12/24 hours real time clock, automatic daylight saving time. 3 SCHEDULE FUNCTION The schedule timer functions are: a maximum of 5 actions can be programmed for each day of the week, 3 independent schedules can be programmed, schedule can be enabled/disabled at any time, linked to a cool temperature and/or heat temperature or an OFF operation (with or without a setback temperature), "last command" overrules previous command until next scheduled command. 4 SETBACK The setback function maintains the room temperature in a specific range when the occupants are out for a longer period and the airconditioning is switched OFF. 5 PROHIBIT BUTTON/FUNCTION Buttons, functions and/or modes can be locked to limit the user action. 6 DETAILED DISPLAY POSSIBILITY Additionally possible to display the outdoor temperature or room temperature. 7 Duty rotation Auto backup unit and auto rotation to maximize your airconditioners' life. 8 Demand control Make up an energy reduction schedule. 9 Quiet mode Schedule a quiet mode for your outdoor unit(s). 10 INTERLOCK WITH 2 EXTERNAL SIGNALS (Only available when the BRP7A51 Digital Input Adapter is connected) Connect up to two switch contacts (contact B1 and B2). Typical application: hotel interlock with field supplied window contact B1 and key card B2. 3. Name and function of switches 1 OPERATION MODE SELECTOR BUTTON To select the operation mode of your preference. 2 FAN SPEED/AIRFLOW DIRECTION SETTING BUTTON To enter the fan speed/airflow direction setting screen. 3 MENU/ENTER BUTTON To enter the main menu or the selected setting item. 4 UP/DOWN BUTTON To raise/lower the set temperature, to highlight the next item on the upper/lower side or to change the selected item. 5 RIGHT/LEFT BUTTON To highlight the next item on the right/left-hand side. 6 ON/OFF BUTTON To start or stop the system. 7 OPERATION LAMP Lights up during operation or blinks if a malfunction occurs. 8 CANCEL BUTTON To return to the previous screen. 9 LCD (with backlight) When pushing any operation button, the backlight will be lit for approximately 30 seconds. When 1 indoor unit is controlled by 2 remote controllers, the backlight of the remote controller operated earlier than the other one will be lit. 4. Name and function of icons To change between the standard display and the detailed display refer to "17.4 To select the display mode". Standard display Detailed display 1 OPERATION MODE 2 FAN SPEED Indicates the fan speed that is set for the air conditioner. If the air conditioner does not have fan speed control function, the fan speed will not be displayed. 3 SET/SETBACK TEMPERATURE DISPLAY When the unit is turned on, Set to indicates the temperatures that are set for the air conditioner. When the unit is turned off, Setback indicates the temperatures that are set for the setback function. 4 DEFROST/HOT START Indicates that the defrost/hot start mode is active. 5 MESSAGE Messages can be displayed. 6 VENTILATION/CLEANING Ventilation mode icons indicate the current ventilation mode (HRV only) (AUTOMATIC, ENERGY RECLAIM VENT., BYPASS). Air Cleaning unit icon indicates that the air cleaning unit (option) is operational. 7 DISPLAY Indicates that the key lock is set or the menu button is prohibited. 8 DISPLAY Indicates that schedule timer or OFF timer is enabled. DISPLAY Indicates that the clock needs to be set. The schedule timer function will not work until the clock is set. 9 EXTERNAL CONTROL ICON Indicates that another controller with higher priority is controlling or disabling your remote controller. 10 CHANGEOVER UNDER CENTRALISED CONTROL ICON Indicates that the changeover of the installation is under centralised control assigned to another indoor unit or optional cool/ heat selector connected to the outdoor unit (= master remote controller). 11 SETBACK ICON Flashes when the unit is turned on under the setback control. 12 AIRFLOW DIRECTION Is displayed when the airflow direction and swing are set. 13 CLOCK (12/24 Hours real time clock) Is displayed when the clock is set. If the clock is not set, - : - is displayed. 14 DETAILED SELECTION Is displayed when the detailed display items are selected. 15 ROTATION Indicates one unit is set as back-up and rotation mode is enabled. 16 QUIET MODE Indicates the HVAC system runs in quiet mode or under demand control. 5. Description of the operation modes 1 FAN ONLY OPERATION In this mode, air only circulates without heating or cooling. 2 DRY OPERATION In this mode, the air humidity will be lowered with a minimal temperature decrease. The temperature and fan speed are controlled automatically and cannot be controlled by the remote controller. Dry operation will not function if the room temperature is too low. 3 AUTOMATIC OPERATION In this mode, the controller will automatically switch between heating and cooling as required by the setpoint. 4 COOLING OPERATION In this mode, cooling will be activated as required by the setpoint or limit operation. 5 HEATING OPERATION In this mode, heating will be activated as required by the setpoint or setback operation. 6 VENTILATION (HRV only) The ventilation mode operates the HRV; refer to the HRV manual for more details. 7 SETBACK SETBACK is a feature that enables to keep the room temperature in a specific range when the occupants are out and the airconditioning is switched OFF. For example: If the room temperature drops below 10°C, heating is started automatically. As soon as 12°C is reached, the controller returns to its original status. If the room temperature goes above 35°C, cooling is started automatically. As soon as 33°C is reached, the controller returns to its original status. The differential can be adjusted in the Setback configuration menu. The setback temperature can be set during the unit is turned off on basic screen or set in the schedule. 6. Basic operation method a Operation mode b Temperature: When the unit is turned on, Set to indicates the temperatures that are set for the air conditioner. When the unit is turned off, Setback indicates the temperatures that are set for the setback function. c Fan speed/Airflow direction 1 Push several times until the desired operation mode Cool, Heat, Vent, Fan, Dry, or Auto is selected. 2 Push . The operation lamp will light and the system starts operating. 3 Use to set the temperature. 4 Push . 5 Use to select airflow Level or Direction setting. 6 With fan speed setting selected, use to select the desired fan speed. 7 With airflow direction setting selected, use to change the setting to Swing, Pos. 0, Pos. 1, Pos. 2, Pos. 3, and Pos. 4. 8 Push to display the basic screen. 9 Push . The operation lamp will turn off and the system stops operating. Additional features of the controller: KEY LOCK 1 Push for 4 seconds to enable the key lock mode. The key lock icon is displayed. 2 To cancel the key lock mode, push for 4 seconds. The key lock icon disappears. 7. Description of the items in the main menu 1 LOCK To prohibit buttons, functions or modes. 2 ROTATION To enable the duty rotation functionality. (Only available with indoor units that support duty rotation) 3 AIRFLOW DIRECTION 1 /INDIVIDUAL AIR DIRECTION (only if the individual airflow function is installed) To set the airflow direction for each 4 flaps individually. 4 QUICK START 1 (SkyAir only) To quickly set the room temperature to a comfortable temperature. 5 VENTILATION To set the ventilation rate and the ventilation mode (HRV only). 6 ENERGY SAVING OPTIONS This allows you to restrict the setting temperature range and display the energy consumption. Setpoint Range Setting Energy saving list Setback condition Sensing sensor (Low) 1, 2 (Only if sensing sensor is installed) Sensing sensor (Stop) 1, 2 (Only if sensing sensor is installed) Setpoint Auto Reset OFF Timer Auto display OFF For more information refer to the detailed user reference guide 3 Energy Consumption 1 7 SCHEDULE 4 To set the startup time and operation stop time for any day of the week. It is possible to set up to 5 actions per day. Both operation modes (normal and setback) can be selected. Additionally the holiday settings and schedule nr can be set. 8 MAINTENANCE INFORMATION Is used to display the service contact and model info. 9 CONFIGURATION To set the LCD contrast. You can also switch between standard and detailed display. When detailed display is selected, the detailed display settings can be changed. You can also set Quiet mode and Draft prevention. 10 CURRENT SETTINGS This shows a list of the current settings for the available items. 11 CLOCK & CALENDAR This allows you to set the date and time. Time can be displayed in either 12 hour or 24 hour time format. 12 LANGUAGE This allows you to set the displayed language. 8. Lock 1 Display the main menu. 2 Press the button for 4 seconds. 3 Use to select the Lock item and press . 4 Use the submenu's to prohibit buttons, functions or modes. For more information refer to the detailed user reference guide 3 . 9. Rotation 1 Display the main menu. 2 Push the button for 4 seconds. 3 Use to select the Rotation function and press . 4 Use the submenu to Enable or Disable Rotation and to configure the rotation cycle. For more information refer to the detailed installer reference guide 3 . 10. Airflow direction 1 /Individual air direction For more information refer to the detailed user reference guide 3 . 11. Quick start (SkyAir only) 1 1 Display the Main Menu and proceed step (9) to display the basic screen (Refer to "22. Main menu structure" and "Appendix"). 2 Quick Start will appear on the basic screen when the Quick Start function is turned ON. 12. Ventilation Only in case an HRV is connected. Refer to the HRV manuals for more information. 13. Energy saving options For more information refer to the detailed user reference guide 3 . 14. Schedule 14.1 To enable/disable the schedule 1 Display the Enable/Disable setting screen (14.1) (Refer to "22. Main menu structure" and "Appendix"). 2 Use to change the setting to Enable or Disable. 3 Push to display the confirmation screen. 4 Use to select Yes and push . 14.2 To select the schedule number 1 Display the Select Schedule screen (14.2) (Refer to "22. Main menu structure" and "Appendix"). 2 Use to change the setting to Schedule nr 1, Schedule nr 2, or Schedule nr 3. 3 Push to display the confirmation screen. 4 Use to select Yes and push . 14.3 To use the holidays The schedule timer will be disabled for the days that have been set as holiday. 1 Display the Holidays screen (14.3) (Refer to "22. Main menu structure" and "Appendix"). 2 Use to select the desired day. Push to display to set the holiday. 3 Push to display the confirmation screen. 4 Use to select Yes and push . 14.4 To change the schedule settings of the selected schedule nr The schedule timer will be disabled for the days that have been set as holiday. 1 Display the Settings screen (14.4) (Refer to "22. Main menu structure" and "Appendix"). 2 Use to select the desired day (1). 3 Use to highlight the Operation start Time and to set the desired Operation start Time (2). 4 Use to highlight the action and to select the desired Act. 5 Use to highlight the temperature and to select the desired value. 6 To set a different day of the week, use to highlight the day. Use to change the day. 7 To copy all actions of the day previously set, push . 8 When the entire schedule settings are completed, push to display the confirmation screen. 9 Use to select Yes and push . 15. Filter auto clean This function is available only on the model whose panel has automatic cleaning function of filter. Needs to be set when operation is OFF. 16. Maintenance information 1 Display the Maintenance Information screen (16) (Refer to "22. Main menu structure" and "Appendix"). 2 The phone number for the Contact info will appear at the top of the screen. The model info of the Indoor unit and Outdoor unit of your product will appear on the bottom of the screen. 3 Push to return to the Main Menu. 17. Configuration 17.1 To select quiet mode enable/disable 1 Display the Quiet Operation Mode settings screen. 2 Display the Enable/Disable screen (17.1) (Refer to "22. Main menu structure" and "Appendix"). 3 Use to select Enable or Disable. 4 Push to display the confirmation screen. 5 Use to select Yes and push . 17.2 To select quiet mode settings 1 Display the Quiet Operation Mode settings screen. 2 Display the Settings screen (17.2). 3 Use to select the start or End time. Installation and operation manual a 3P419248-1-KA OPERATION Also see operation manual attached to the outdoor and indoor unit. WARNING Do NOT play with the unit or its remote controller. Accidental operation by a child may result in impairment of bodily functions and harm health. WARNING Never disassemble the remote controller. Touching the interior parts may result in electric shocks or fire. Consult your Daikin dealer or authorized contactor for internal inspections and adjustments. WARNING To avoid electric shocks, do not operate with wet hands. WARNING Do NOT modify or repair the remote controller. This may result in electric shocks or fire. Consult your Daikin dealer. Do NOT relocate or reinstall the remote controller by yourself. Improper installation may result in electric shocks or fire. Consult your Daikin dealer. Do NOT use flammable materials (e.g. hairspray or insecticide) near the product. Do not clean the product with organic solvents such as paint thinner. The use of organic solvents may cause crack damage to the product, electric shocks, or fire. INFORMATION This is the only button that works when the backlight is not lit. With icons With icons and text (default) With icons With icons and text Operation mode cool Heat Vent Air Clean Fan Dry Auto (Cool) Auto(Heat) 1 9 4 5 3 2 8 6 7 28°C 1 11 3 8 4 5 10 2 9 6 Heat Set to 28°C Error: Push Menu button 1 11 3 8 7 4 5 10 2 9 6 Fri 11 : 03 14 3 13 15 12 16 Fri 11 : 03 Error: Push Menu button Heat Set to Room 14 3 7 13 15 12 16 Return Setting a c b Cool Return Set to Cool INFORMATION When in Dry or Vent mode, the fan speed can not be set. INFORMATION When in Dry or Vent mode, the fan speed can not be set. 1. This function is not compatible with SkyAir RR+RQ units. 2. In case of a simultaneous operation system, the system is controlled by the sensing sensor mounted in the master indoor unit. 3. The detailed user reference guide and installer reference guide are available on http:// www.daikineurope.com/support-and-manuals/ product-information/ . Return Setting Return Setting Airflow level/direction Level Direction Position 0 Low 1 2 3 4 0 0 1 2 3 4 Cool Return Setting Set to Cool 4. The schedule will not be available when a centralised controller or the BRP7A51 Digital Input Adapter is connected. INFORMATION Repeat this procedure to turn Quick Start function off. Return Setting Enable/Disable Schedule Disable Setting Select Schedule Schedule Schedule nr 1 Return INFORMATION (Act column) There are 3 types of operations: 1. The temperature setpoints can be configured. 2. The setback temperature setpoints can be configured. 3. The temperature and setback temperature setpoints are disabled. INFORMATION (Cool and Heat column) __: Indicates that the temperature setpoint for cool/heat and setback temperature setpoint for this time period is not specified. The last active setpoint will be utilized. - -: Indicates that the setback function is disabled for this time period with action OFF. Return Setting Schedule Holidays Multiple Selection Sun Mon Tue Wed Thu Fri Sat (1) Setting Schedule nr 1 Mon Time Act Cool Heat 6 :00 : : : : Return (2) Setting Schedule nr 1 Mon Time Act Cool Heat 6:00 : : : : ON OFF 1 2 3

Upload: duongnhi

Post on 08-Apr-2018

231 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Installation and operation manual€¦ ·  · 2017-02-20Installation and operation manual BRC1E53 1 3P419248-1-KA–2015.09 The English text is the original instruction. Other languages

BRC1E533P419248-1-KA – 2015.09

ULE4

startup time and operation stop time for any day of the possible to set up to 5 actions per day. Both operationormal and setback) can be selected. Additionally thettings and schedule nr can be set.

ENANCE INFORMATIONdisplay the service contact and model info.

GURATION LCD contrast. You can also switch between standardd display. When detailed display is selected, the detailed

ttings can be changed. You can also set Quiet mode andention.

NT SETTINGSs a list of the current settings for the available items.

& CALENDARs you to set the date and time. Time can be displayed inour or 24 hour time format.

AGEs you to set the displayed language.

ck the main menu.

he button for 4 seconds.

to select the Lock item and press .

submenu's to prohibit buttons, functions or modes.

nformation refer to the detailed user reference guide3.

tation the main menu.

e button for 4 seconds.

to select the Rotation function and press .

e submenu to Enable or Disable Rotation and tore the rotation cycle. information refer to the detailed installer reference

flow direction1/Individual air directionnformation refer to the detailed user reference guide3.

ick start (SkyAir only)1

the Main Menu and proceed step (9) to display the basic (Refer to "22. Main menu structure" and "Appendix").art will appear on the basic screen when the Quick Startn is turned ON.

ntilationse an HRV is connected. Refer to the HRV manuals formation.

ergy saving optionsnformation refer to the detailed user reference guide3.

hedule

able/disable the schedule the Enable/Disable setting screen (14.1) (Refer to "22. Maintructure" and "Appendix").

to change the setting to Enable or Disable.

to display the confirmation screen.

to select Yes and push .

lect the schedule number the Select Schedule screen (14.2) (Refer to "22. Maintructure" and "Appendix").

to change the setting to Schedule nr 1, Schedule nr 2,dule nr 3.

to display the confirmation screen.

to select Yes and push .

14.3 To use the holidaysThe schedule timer will be disabled for the days that have been setas holiday.1 Display the Holidays screen (14.3) (Refer to "22. Main menu

structure" and "Appendix").2 Use to select the desired day. Push to display to

set the holiday.

3 Push to display the confirmation screen.

4 Use to select Yes and push .

14.4 To change the schedule settings of the selected schedule nrThe schedule timer will be disabled for the days that have been setas holiday.1 Display the Settings screen (14.4) (Refer to "22. Main menu

structure" and "Appendix").2 Use to select the desired day (1).3 Use to highlight the Operation start Time and to set

the desired Operation start Time (2).

4 Use to highlight the action and to select the desiredAct.

5 Use to highlight the temperature and to select thedesired value.

6 To set a different day of the week, use to highlight the day.Use to change the day.

7 To copy all actions of the day previously set, push .

8 When the entire schedule settings are completed, push todisplay the confirmation screen.

9 Use to select Yes and push .

15. Filter auto cleanThis function is available only on the model whose panel hasautomatic cleaning function of filter. Needs to be set whenoperation is OFF.

16. Maintenance information1 Display the Maintenance Information screen (16) (Refer to "22. Main

menu structure" and "Appendix").2 The phone number for the Contact info will appear at the top of the

screen. The model info of the Indoor unit and Outdoor unit of yourproduct will appear on the bottom of the screen.

3 Push to return to the Main Menu.

17. Configuration

17.1 To select quiet mode enable/disable1 Display the Quiet Operation Mode settings screen.2 Display the Enable/Disable screen (17.1) (Refer to "22. Main

menu structure" and "Appendix").3 Use to select Enable or Disable.

4 Push to display the confirmation screen.

5 Use to select Yes and push .

17.2 To select quiet mode settings1 Display the Quiet Operation Mode settings screen.2 Display the Settings screen (17.2).3 Use to select the start or End time.

The schedule will not be available when a centralised controller or the BRP7A51 Digital Input Adapter is connected.

FORMATIONpeat this procedure to turn Quick Start function off.

Return Setting

Enable/Disable Schedule

Disable

Setting

Select ScheduleSchedule

Schedule nr 1

Return

INFORMATION (Act column)There are 3 types of operations:1. The temperature setpoints can be configured.2. The setback temperature setpoints can be configured.3. The temperature and setback temperature setpoints

are disabled.

INFORMATION (Cool and Heat column)__: Indicates that the temperature setpoint for cool/heatand setback temperature setpoint for this time period is notspecified. The last active setpoint will be utilized.- -: Indicates that the setback function is disabled for thistime period with action OFF.

Return Setting

ScheduleHolidays Multiple Selection

Sun Mon Tue Wed Thu Fri Sat

(1)

Setting

Schedule nr 1

MonTime Act Cool Heat– 6 :00

: : : :

Return

(2)

Setting

Schedule nr 1

MonTime Act Cool Heat– 6 :00

: : : :

ON

OFF

1

2

3

Installation and operation manual1

The English text is the original instruction. Other languages aretranslations of the original instructions.Refer to http://www.daikineurope.com/support-and-manuals/product-information/ for more detailed user reference guides.Installation: see page 2.

1. General safety precautions

Please read these "1. General safety precautions" carefully beforeinstalling air conditioning equipment and be sure to install itcorrectly.Failure to follow these instructions properly may result in propertydamage or personal injury, which may be serious depending on thecircumstances.

2. Features and functionsThe BRC1E53 is a state of the art remote controller that offers fullcontrol over your installation.

1 BASIC REMOTE CONTROLLERThe basic remote controller functions are: ON/OFF, operation mode change-over, temperature adjustment, air volume adjustment, airflow direction adjustment.

2 CLOCK FUNCTIONThe clock functions are: 12/24 hours real time clock, automatic daylight saving time.

3 SCHEDULE FUNCTIONThe schedule timer functions are: a maximum of 5 actions can be programmed for each day of

the week, 3 independent schedules can be programmed, schedule can be enabled/disabled at any time, linked to a cool temperature and/or heat temperature or an

OFF operation (with or without a setback temperature), "last command" overrules previous command until next

scheduled command.

4 SETBACKThe setback function maintains the room temperature in a specificrange when the occupants are out for a longer period and theairconditioning is switched OFF.

5 PROHIBIT BUTTON/FUNCTIONButtons, functions and/or modes can be locked to limit the useraction.

6 DETAILED DISPLAY POSSIBILITYAdditionally possible to display the outdoor temperature or roomtemperature.

7 Duty rotationAuto backup unit and auto rotation to maximize yourairconditioners' life.

8 Demand controlMake up an energy reduction schedule.

9 Quiet modeSchedule a quiet mode for your outdoor unit(s).

10 INTERLOCK WITH 2 EXTERNAL SIGNALS(Only available when the BRP7A51 Digital Input Adapter isconnected) Connect up to two switch contacts (contact B1 and B2). Typical application: hotel interlock with field supplied window

contact B1 and key card B2.

3. Name and function of switches

1 OPERATION MODE SELECTOR BUTTONTo select the operation mode of your preference.

2 FAN SPEED/AIRFLOW DIRECTION SETTING BUTTONTo enter the fan speed/airflow direction setting screen.

3 MENU/ENTER BUTTONTo enter the main menu or the selected setting item.

4 UP/DOWN BUTTONTo raise/lower the set temperature, to highlight the next item on theupper/lower side or to change the selected item.

5 RIGHT/LEFT BUTTONTo highlight the next item on the right/left-hand side.

6 ON/OFF BUTTONTo start or stop the system.

7 OPERATION LAMPLights up during operation or blinks if a malfunction occurs.

8 CANCEL BUTTONTo return to the previous screen.

9 LCD (with backlight)When pushing any operation button, the backlight will be lit forapproximately 30 seconds. When 1 indoor unit is controlled by 2remote controllers, the backlight of the remote controller operatedearlier than the other one will be lit.

4. Name and function of iconsTo change between the standard display and the detailed displayrefer to "17.4 To select the display mode".

Standard display

Detailed display

1 OPERATION MODE

2 FAN SPEEDIndicates the fan speed that is set for the air conditioner. If the airconditioner does not have fan speed control function, the fan speedwill not be displayed.

3 SET/SETBACK TEMPERATURE DISPLAYWhen the unit is turned on, Set to indicates the temperatures thatare set for the air conditioner.When the unit is turned off, Setback indicates the temperatures thatare set for the setback function.

4 DEFROST/HOT START Indicates that the defrost/hot start mode is active.

5 MESSAGEMessages can be displayed.

6 VENTILATION/CLEANING Ventilation mode icons indicate the current

ventilation mode (HRV only) (AUTOMATIC, ENERGY RECLAIM VENT.,BYPASS).

Air Cleaning unit icon indicates that the air cleaning unit(option) is operational.

7 DISPLAYIndicates that the key lock is set or the menu button is prohibited.

8 DISPLAY

Indicates that schedule timer or OFF timer is enabled.

DISPLAY

Indicates that the clock needs to be set. The schedule timerfunction will not work until the clock is set.

9 EXTERNAL CONTROL ICON Indicates that another controller with higher priority is controlling ordisabling your remote controller.

10 CHANGEOVER UNDER CENTRALISED CONTROL ICON

Indicates that the changeover of the installation is undercentralised control assigned to another indoor unit or optional cool/heat selector connected to the outdoor unit (= master remotecontroller).

11 SETBACK ICON Flashes when the unit is turned on under the setback control.

12 AIRFLOW DIRECTION Is displayed when the airflow direction and swing are set.

13 CLOCK (12/24 Hours real time clock)Is displayed when the clock is set. If the clock is not set, - : - isdisplayed.

14 DETAILED SELECTIONIs displayed when the detailed display items are selected.

15 ROTATION Indicates one unit is set as back-up and rotation mode is enabled.

16 QUIET MODE Indicates the HVAC system runs in quiet mode or under demandcontrol.

5. Description of the operation modes1 FAN ONLY OPERATIONIn this mode, air only circulates without heating or cooling.

2 DRY OPERATIONIn this mode, the air humidity will be lowered with a minimaltemperature decrease.The temperature and fan speed are controlled automatically andcannot be controlled by the remote controller. Dry operation will not function if the room temperature is too low.

3 AUTOMATIC OPERATIONIn this mode, the controller will automatically switch betweenheating and cooling as required by the setpoint.

4 COOLING OPERATIONIn this mode, cooling will be activated as required by the setpoint orlimit operation.

5 HEATING OPERATIONIn this mode, heating will be activated as required by the setpoint orsetback operation.

6 VENTILATION (HRV only)The ventilation mode operates the HRV; refer to the HRV manualfor more details.

7 SETBACK

SETBACK is a feature that enables to keep the room temperaturein a specific range when the occupants are out and theairconditioning is switched OFF.For example: If the room temperature drops below 10°C, heating is started

automatically. As soon as 12°C is reached, the controllerreturns to its original status.

If the room temperature goes above 35°C, cooling is startedautomatically. As soon as 33°C is reached, the controllerreturns to its original status.

The differential can be adjusted in the Setback configuration menu.The setback temperature can be set during the unit is turned off onbasic screen or set in the schedule.

6. Basic operation method

a Operation modeb Temperature:

• When the unit is turned on, Set to indicates the temperatures that are set for the air conditioner.

• When the unit is turned off, Setback indicates the temperatures that are set for the setback function.

c Fan speed/Airflow direction

1 Push several times until the desired operation mode Cool,

Heat, Vent, Fan, Dry, or Auto is selected.

2 Push . The operation lamp will light and the system startsoperating.

3 Use to set the temperature.

4 Push .5 Use to select airflow Level or Direction setting.

6 With fan speed setting selected, use to select the desiredfan speed.

7 With airflow direction setting selected, use to change thesetting to Swing, Pos. 0, Pos. 1, Pos. 2, Pos. 3, and Pos. 4.

8 Push to display the basic screen.

9 Push . The operation lamp will turn off and the system stopsoperating.

Additional features of the controller: KEY LOCK

1 Push for 4 seconds to enable the key lock mode. The keylock icon is displayed.

2 To cancel the key lock mode, push for 4 seconds. The keylock icon disappears.

7. Description of the items in the main menu1 LOCKTo prohibit buttons, functions or modes.

2 ROTATIONTo enable the duty rotation functionality.(Only available with indoor units that support duty rotation)

3 AIRFLOW DIRECTION1/INDIVIDUAL AIR DIRECTION (only if the individual airflow function is installed)

To set the airflow direction for each 4 flaps individually.

4 QUICK START1 (SkyAir only)To quickly set the room temperature to a comfortable temperature.

5 VENTILATIONTo set the ventilation rate and the ventilation mode (HRV only).

6 ENERGY SAVING OPTIONSThis allows you to restrict the setting temperature range anddisplay the energy consumption. Setpoint Range Setting Energy saving list Setback condition Sensing sensor (Low)1, 2 (Only if sensing sensor is installed) Sensing sensor (Stop)1, 2 (Only if sensing sensor is installed) Setpoint Auto Reset OFF Timer Auto display OFF

For more information refer to the detailed user referenceguide3

Energy Consumption1

7 SCHEDTo set theweek. It ismodes (nholiday se

8 MAINTIs used to

9 CONFITo set theand detailedisplay seDraft prev

10 CURREThis show

11 CLOCKThis alloweither 12 h

12 LANGUThis allow

8. Lo1 Display

2 Press t

3 Use

4 Use the

For more i

9. Ro1 Display

2 Push th

3 Use

4 Use thconfigu

For moreguide3.

10. AirFor more i

11. Qu1 Display

screen2 Quick St

functio

12. VeOnly in camore infor

13. EnFor more i

14. Sc

14.1 To en1 Display

menu s2 Use

3 Push

4 Use

14.2 To se1 Display

menu s2 Use

or Sche

3 Push

4 Use

Installation andoperation manual

a 3P419248-1-KA

OPERATION

Also see operation manual attached to the outdoor andindoor unit.

WARNINGDo NOT play with the unit or its remote controller.Accidental operation by a child may result in impairment ofbodily functions and harm health.

WARNINGNever disassemble the remote controller. Touching theinterior parts may result in electric shocks or fire. Consultyour Daikin dealer or authorized contactor for internalinspections and adjustments.

WARNINGTo avoid electric shocks, do not operate with wet hands.

WARNING Do NOT modify or repair the remote controller. This

may result in electric shocks or fire. Consult yourDaikin dealer.

Do NOT relocate or reinstall the remote controller byyourself. Improper installation may result in electricshocks or fire. Consult your Daikin dealer.

Do NOT use flammable materials (e.g. hairspray orinsecticide) near the product. Do not clean theproduct with organic solvents such as paint thinner.The use of organic solvents may cause crack damageto the product, electric shocks, or fire.

INFORMATIONThis is the only button that works when the backlight is notlit.

With icons With icons and text (default)

With icons With icons and text

Operation mode

cool Heat Vent Air Clean

Fan Dry Auto (Cool) Auto(Heat)

1

94

5

3

2 8

6

7

28°C 1

11

3

8

45

10

2

9

6

Heat Set to

28°C

Error: Push Menu button

1

11

3

87

45

10

2

9

6

Fri 11:03

143 13

15

12

16Fri 11:03

Error: Push Menu button

Heat Set to Room

143 7

13 15

12

16

Return Setting

a

cb

Cool

Return

Set toCool

INFORMATIONWhen in Dry or Vent mode, the fan speed can not be set.

INFORMATIONWhen in Dry or Vent mode, the fan speed can not be set.

1. This function is not compatible with SkyAir RR+RQ units.

2. In case of a simultaneous operation system, the system is controlled by the sensing sensor mounted in the master indoor unit.

3. The detailed user reference guide and installer reference guide are available on http://www.daikineurope.com/support-and-manuals/product-information/ .

Return SettingReturn Setting

Airflow level/direction

Level DirectionPosition 0Low

1 2 3 4

0 0

1 2 3 4

Cool

Return Setting

Set toCool

4.

INRe

Page 2: Installation and operation manual€¦ ·  · 2017-02-20Installation and operation manual BRC1E53 1 3P419248-1-KA–2015.09 The English text is the original instruction. Other languages

Installation and operation manual2

ENDIX

Return Setting

(10)

Cool Set toCool

VentilationVentilation rateVentilation mode

RotationEnable/DisableRotation Cycle Time Setting

Energy Saving OptionsEnergy Saving ListSetpoint RangeSetback ConditionSensing Sensor (low)Sensing Sensor (stop)Setpoint Auto ResetOff TimerAuto Display OffEnergy Consumption

Main MenuLock FunctionRotationAirflow DirectionIndividual Air DirectionQuick StartVentilationEnergy Saving OptionsScheduleFilter Auto CleanMaintenance InformationConfigurationCurrent SettingsClock & CalendarLanguage

ScheduleEnable/Disable (14.1)Select Schedule (14.2)Holidays (14.3)Settings (14.4)

(14)

(13)

(16)

(20)

(10)

(9)

(8)

(12)

(15)

(17)

(18)

(19)

ConfigurationQuiet Operation ModeDraft prevention (17.3)DisplayContrast adjustment (17.6)

DisplayDisplay Mode (17.4)Display Item (17.5)

Quiet Operation ModeEnable/Disable (17.1)Settings (17.2)

Clock & CalendarDate & Time (19.1)12H/24H Clock (19.2)

Maintenance Information

Current Settings

Language

Filter auto clean

Lock FunctionProhibit ButtonsFunction ProhibitionProhibit Mode

Airflow Direction

Individual Air DirectionIndividual SettingIndividual Setting ListReset All Indivi SettingAirflow Direction Range

BRC1E533P419248-1-KA – 2015.09

4 Use to modify the time.

5 Push to display the confirmation screen.

6 Use to select Yes and push .

17.3 To select the draft prevention1 Display the Draft prevention settings screen (17.3) (Refer to

"22. Main menu structure" and "Appendix").2 Use to select Enable or Disable.

3 Push to display the confirmation screen.

4 Use to select Yes and push .

17.4 To select the display mode1 Display the Display Mode settings screen (17.4) (Refer to

"22. Main menu structure" and "Appendix").2 Use to change the setting to Standard or Details.

3 Push to confirm the setting. Basic screen is displayed.

17.5 To select the detailed display item1 Display the Display Item settings screen (17.5) (Refer to

"22. Main menu structure" and "Appendix").2 Use to change the setting to None, Outside Air Temp,

Room Temp or System.

3 Push to confirm the setting. Basic screen is displayed.

17.6 To adjust the contrast of the LCD1 Display the Contrast adjustment settings screen (17.6) (Refer to

"22. Main menu structure" and "Appendix").2 Use to change the contrast.

3 Push to confirm the setting.

18. Current settings1 Display the Setting status list screen (18) (Refer to "22. Main menu

structure" and "Appendix").2 A list of the current setting status is displayed.

3 Push to return to the Main Menu.

19. Clock & calendar

19.1 To set the date & time1 Display the Date & Time settings screen (19.1) (Refer to "22. Main

menu structure" and "Appendix").2 Use to select and to set Year, Month, Day, and time.

3 Push to display the confirmation screen.

4 Use to select Yes and push .

19.2 To set the hour format (12/24 hours)1 Display the 12H/24H Clock settings screen (19.2) (Refer to

"22. Main menu structure" and "Appendix").2 Use to select 12H or 24H.

3 Push to display the confirmation screen.

4 Use to select Yes and push .

20. Language1 Display the Language screen (20) (Refer to "22. Main menu

structure" and "Appendix").2 Use to select the language.

3 Push to confirm the setting. Basic screen is displayed.

21. Error code display1 If an error occurs, Error: Push Menu Button or Warning: Push Menu Button

will blink in the basic screen.

2 Push . The error code will blink and the Contact Info andmodel info will be displayed.

22. Main menu structureSee "Appendix".

For more information refer to the detailed installer referenceguide1.

1. General safety precautions

Please read these "1. General safety precautions" carefully beforeinstalling the remote controller.Improper installation or attachment of equipment or accessoriescould result in electric shock, short-circuit, leaks, fire or otherdamage to the equipment or personal injury.If unsure of installation procedures or use, always contact yourdealer for advice and information.Do NOT install the remote controller by yourself. Improperinstallation may result in electric shocks or fire. Consult your Daikindealer.

After finishing installation: conduct a trial operation to check for faults, explain the customer how to operate the remote controller,

using the Operation part of this manual, ask the customer to store the manual for future reference.

2. What is in the box

1 Remote controller2 Wood screws+wall plugs3 Small screws4 Clamp5 Installation and operation manual6 Wiring retainer

3. Remove the upper part of remote controller

Insert a slot screwdriver into the slots (1)in the lower part of the remote controller(2 places), and remove the upper part ofthe remote controller.

4. Fasten the remote controller

1 for exposed mounting, fasten with the 2 included wood screws (Ø3.5x32) and plugs.

2 for flush-mounting, fasten with the 2 included machine screws (M4x16).

For the field supplied switch box, use optional accessory KJB111Aor KJB211A.

5. Wire the indoor unit4 methods:

1 from the rear,

2 from the left,

3 from the top,

4 from the top center.

1 indoor unit2 notch the part for the wiring to pass through with nippers,

etc.3 secure the wiring to the uppercase using the wiring

retainer and clamp.Connect the terminals on the remote controller (P1, P2), and theterminals of the indoor unit (P1, P2). (P1 and P2 do not havepolarity.)

Wiring specifications

6. Reattach the upper part of the remote controller

Align the upper case with the tabs of thelower case (6 points), insert and installthe upper case.First begin fitting from the clips at thebottom.

7. Power on1 Put on the power.2 Checking the connection. Please stand by. is displayed.3 After a few seconds, the basic screen is displayed.

If controlling 1 indoor unit or 1 group of indoor units with 2 remote controllers1 Put on the power for both remote controllers.2 Determine which one is the sub/main remote controller.3 When Error code:U5 - Checking the connection. Please stand by. is

displayed on both remote controllers, push and hold the

button of the sub remote controller for 4 seconds.4 The sub remote controller now displays Sub RC.

5 After a few seconds, the basic screen is displayed.

Refer to the detailed installer reference guide1 for more detailedinstallation instructions concerning: Field settings, Test operation method (in case of SkyAir), Checking procedure of Error History, Registration method of the Maintenance Contact, Confirmation of registered details, Clock & Calendar (see also “19. Clock & calendar” on page 2), Language (see also “20. Language” on page 2), Prohibit button, Function Prohibition, Demand control, Duty rotation, External Input Interlock, Single and Dual Setpoint mode, Software update with Updater.

1. General safety precautionsWipe the LCD and other surface parts of the remote controller witha dry cloth when they become dirty.If the dirt on the surface can not be removed, soak the cloth inneutral detergent diluted with water, squeeze the cloth tightly, andclean the surface. Wipe the surface with a dry cloth then.

2. Filter sign resetting1 When one of the following messages (Time to clean filter, Time to

clean filter and element, or Time to clean element) appears on thebottom of the basic screen, the filter has to be cleaned.

2 After the filter or element is washed, cleaned, or replaced, push to enter the Main Menu.

3 Use to select Reset Filter Indicator and push toreset the filter sign.

INSTALLATION

1. The detailed user reference guide and installer reference guide are available on http://www.daikineurope.com/support-and-manuals/product-information/.

Setting

Date & TimeYear 2011Month 01Day 01Thursday

12:00Return

Cool

Return Setting

Set toCool

Error : Press Menu Button

Carefully read these instructions before installation. Theywill tell you how to install, how to configure and how to usethe unit properly. Keep this manual in a handy place forfuture reference.This is an option to be used in combination with Daikinunits. Refer to the installation and operation manual of theunits for installation and operation instructions.

All field wiring and components must be installed by aninstaller and must comply with the applicable legislation.

NOTICEWhen the remote controller thermo function is used, selectthe installation location considering it should be a place: where the average temperature in the room can be

detected, that is not exposed to direct sunlight, that is not near a heat source, that is not affected by outside air or air draught due to

e.g. door opening/closing, where the display is kept clean. where the front is kept clear. where the temperature is between –10°C and 50°C. where the relative humidity is max. 95%.

NOTICEDo NOT install the remote controller: Near machinery emitting electromagnetic radiation.

Electromagnetic radiation may disturb the operationof the control system and result in a malfunction of theunit.

In moist areas or places where it may be exposed towater. If water enters the remote controller, electricshocks may be caused and the inner electronics mayfail.

WARNINGConsult your local dealer regarding relocation andreinstallation of the remote controller.

NOTICEThe PCB is mounted in the upper part of the remotecontroller. Be careful not to damage the board with the slotscrewdriver.

1 2 3 4 5 61× 7× 1×2× 2× 1×

+

1

1 2 2

INFORMATIONPut on a flat surface. Be careful not to distort the shape ofthe back plate of the remote controller by overtightening themounting screws.

INFORMATIONWhen wiring, run the wiring away from the power supplywiring in order to avoid receiving electric noise (externalnoise).

Wiring type Size

Total length

Sheathed vinyl cord or cable

0.75–1.25 mm2 ≤500 m

1

32

P1 P2

PCB

1x

1

1

2

P1 P2

PCB

2

31x

P1 P21

2

3

PCB

3

31x

1

2

P1 P2

PCB

43

31x

INFORMATION1. Peel the sheat for the part that has to pass through the

inside of the remote controller case (L). Refer to thefigure and the table below. It is important to keepdouble isolation up through the notch of the remotecontroller case.

2. For easy wiring, it’s better to keep ±10 mm differencebetween the length of the 2 wires.

Wiring outlet L

Top outlet ±150 mm

Top center outlet ±200 mm

NOTICEBe careful not to pinch the wiring when attaching.

NOTICE1. The switch box and wiring for connection are not

included.2. Do not directly touch the PCB with your hand.

INFORMATIONThe main remote controller still displays Main RC.

MAINTENANCE

WARNINGDo not use any paint thinner, organic solvent, or strongacid.

WARNINGDo not wash the remote controller. Doing so may causeelectric leakage and result in electric shocks or fire.

WARNINGBe sure to stop the operation of the air conditioner and turnoff the power supply breaker at the time of maintenance.Failure to do so may result in electric shocks or injury.

10 mm

L

APP

(11)