Insertion Turbine Flowmeter Series 5300
The Flow Automation Series 5300 flowmeters are designedfor applications in pipe sizes of 11/2" to 12". They can bemounted permanently or are sufficiently light and portable asto be transferred from location to location.
Applicationsindustrial heating • air conditioning• distribution in gas mains • furnace gas and air flow measurement • water flowmonitoring • oil distribution between storagetanks
versatile and portable
low cost
simple installation through a 1" male tee
wide operating temperature range
head mounted pre-amplifiers or frequency to DCconverters can be supplied
suitable for liquid and low velocity gas use
can be mounted on live line via ‘hot tap’ method
Dimensional drawing
Detailed specification and ordering information: see next pageThermo Measurement reserves the right to alter specifications without notice
Features
ISSUE: 5300/MAR2001/US
SpecificationFlowmeter:Linearity: (Liquids) ±2% of reading over
average, dependent on processapplications
(Gases) ±2% of reading at specified gas pressures
Repeatability: (Liquids) ±0.2%, dependent on application details
Pressure drop: Negligible
Process temperature: 0 to +300°F
Maximum pressure: 100psiG
Materials of construction: Insertion stem and rotor housing:
ANSI 304 stainless steel or similar
Turbine rotor: stainless steel ANSI 431
General:Hazardous area certification: FM approved enclosure Class 1,
Div 1, Groups B, C, D
Installation: Position where the effects of velocity profile distortion and swirling flow are minimized, ie not immediately downstream of bends, valves or other pipe fittings which can cause severe flow disturbances.
If the 5300 meter is to be installed by hot tapping the line through a full port gate valve then a 11/2"riser and gate valve must be used to allow sufficient clearance for the turbine.
If the 5300 is to be installed by only using a riser or pipe tee section then a 1" female NPTconnection can be used.
Outputs:Liquid: >20mV peak to peak at minimum
flow, typically 100mV peak-to-peakat 3ft/s
High velocity gas: >40mV peak to peak at minimum flow, typically 100mV peak-to-peakat 3ft/s
Low velocity gas: >40mV peak to peak at minimum flow, typically 100mV peak-to-peakat 3ft/s
Pre-amplifiers: see Accessory Kits on back page
4-20mA analog
SQ2 pulse pre-amplifiers
Electrical:Power supply: Not required for mV pulse
24Vdc loop for FDC1100
5-24Vdc on 3 wire system for SQ2
Termination: 2 pin Cannon as standard
Terminal block housed in conduit box
Screw terminals on pre-amplifiers
Cable entry: NPT if used with junction box
Ordering InformationModel code format5300 Flow Automation Insertion Turbine Flowmeter
Fluid typeG2 GasL1 Liquid
Flow range ft/s (m/s)A 2 - 40 1 - 12 Liquid applications onlyB 6 - 60 2 - 12 Low velocity gas applications only
Body material0 304 stainless steel
Temperature rangeT1 0 to +300°F (-20 to +150°C)
Process connectionS1 Male NPT (1 inch)
Termination00 Flying leads, suitable for local indicator12 2 pin Cannon connector38 Explosion proof enclosure
CertificationS Non hazardous/safe area operationI Intrinsically safe (consult factory)7 FM Class 1, Div 1, Groups B, C, D
Example: 5300-G2-B-0-T1-S1-00-S
Flow Automation 5300 series insertion turbine flowmeter, low velocity gas application, 6-60ft/s flow range,stainless steel body, 0 to +300°F operation,1" male NPT process connection, flying leads suitable for localindicator, suitable for non-hazardous/safe area operation.
NOTE: TURN TO BACK PAGE FOR ACCESSORY KIT TO COMPLETE YOUR ORDER
Thermo Electron CorporationKing’s WorthyWinchester, HampshireSO23 7QA, United Kingdom
Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]
Thermo Electron Corporation9303 W. Sam Houston Parkway SouthHoustonTexas77099 – 5298 USA
Tel: +1 (713) 272 0404Fax: +1 (713) 272 2273
Turbine Accessory KitsThermo Measurement manufactures a large range of accessory kits for use with Flow Automation turbine meters.
A description of the interface electronics is shown below, together with ordering information and certification guide.
Select from the information below, as shown in the example.
Example: AKS-215 Insertion turbine accessory kit, with local display with rate/totalizer indicator, battery powered
Note 1 - Use termination Code 38 on Ordering Information (p3)Note 2 - Use Termination Code 00
Ordering Information
Interface electronicsModel DescriptionFDC1100 4-20mA analog outputSQ2 5 volt pulse pre-amplifier
Flow Automation Turbine Accessory Kits
AKS Insertion turbine accessory kit Safe area Explosionoperation proof
Signal output100 Uncertified pickup with flying leads Yes No
(see Note 2)
215 Local display with rate/totalizer Yes Noindicator, battery powered (see Note 2)
216 Local display with rate/totalizer Yes Noindicator, 4-20mA output, loop powered (see Note 2)
217 Local display with rate/totalizer with Yes Noalarm, loop powered (see Note 2)
501 FM approved enclosure with terminal block Yes Yes
502 NPT stem with Cannon connector Yes No
503 FM approved enclosure with FDC1100 Yes Yes(see Note 1)
504 FM approved enclosure with SQ2 Yes Yespre-amplifier (see Note 1)
505 FM approved enclosure with rate/totalizer Yes Yes(see Note 1)
Turbine Accessory KitsThermo Measurement manufactures a large range of accessory kits for use with Flow Automation turbine meters.
A description of the interface electronics is shown below, together with ordering information and certification guide.
Select from the information below, as shown in the example.
Ordering Information
A Thermo Electron business
Thermo Measurement LtdKing’s WorthyWinchester, HampshireSO23 7QA, United Kingdom
Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]
Thermo Measurement Ltd9303 W. Sam Houston Parkway SouthHoustonTexas77099 – 5298 USA
Tel: +1 (713) 272 2218Fax: +1 (713) 272 2214
Interface electronicsModel DescriptionFDC1100 4-20mA analogue output
A10 4-20mA current modulated square wave pulse pre-amplifier
Flow Automation Turbine Accessory KitsAKS Insertion turbine accessory kit Operation required in:
Signal output Safe area IS Ex d
100 Uncertified pickup to suit customer’s Yes No Nolocal display
101 Uncertified enclosure with terminal block Yes No No
102 Uncertified enclosure with A10 pre-amplifier Yes No No103 Uncertified enclosure with FDC1100 Yes No No
frequency to current convertor
200 IS certified pickup to suit customer’s local Yes Dependent Nodisplay on display
201 IS certified pickup and terminal block Yes Yes No
202 IS certified A10 pre-amplifier Yes Yes No205 Local display with rate/totaliser indicator, Yes Yes No
10 point linearisation, battery powered
206 Local display with rate/totaliser indicator, Yes Yes No4-20mA output, 10 point linearisation, looppowered
207 Local display with rate/totaliser with Yes Yes No4-20mA output and alarm, 10 point linearisation, loop powered
301 Terminal block suitable for flame proof Yes No Yesenclosure (see Note 1)
302 Flame proof A10 pre-amplifier (see Note 1) Yes No Yes
303 Flame proof FDC1100 frequency to current Yes No Yesconvertor (see Note 1)
502 M25 stem with Cannon connector Yes No No
Note 1 - Use termination Code 37 on flowmeter Ordering Information
Insertion turbine accessory kit, with local display with rate/totaliser indicator, battery poweredExample: AKS-205