Insertion Turbine Flowmeter Series 5300 The Flow Automation Series 5300 flowmeters are designed for applications in pipe sizes of 1 1 / 2" to 12". They can be mounted permanently or are sufficiently light and portable as to be transferred from location to location. Applications industrial heating • air conditioning • distribution in gas mains • furnace gas and air flow measurement • water flow monitoring • oil distribution between storage tanks versatile and portable low cost simple installation through a 1" male tee wide operating temperature range head mounted pre-amplifiers or frequency to DC converters can be supplied suitable for liquid and low velocity gas use can be mounted on live line via ‘hot tap’ method Dimensional drawing Detailed specification and ordering information: see next page Thermo Measurement reserves the right to alter specifications without notice Features ISSUE: 5300/MAR2001/US

Upload: others

Post on 28-Jun-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Insertion Turbine Flowmeter Series 5300 - Gilson EngFlow Automation Turbine Accessory Kits AKS Insertion turbine accessory kit Safe area Explosion operation proof Signal output 100

Insertion Turbine Flowmeter Series 5300

The Flow Automation Series 5300 flowmeters are designedfor applications in pipe sizes of 11/2" to 12". They can bemounted permanently or are sufficiently light and portable asto be transferred from location to location.

Applicationsindustrial heating • air conditioning• distribution in gas mains • furnace gas and air flow measurement • water flowmonitoring • oil distribution between storagetanks

versatile and portable

low cost

simple installation through a 1" male tee

wide operating temperature range

head mounted pre-amplifiers or frequency to DCconverters can be supplied

suitable for liquid and low velocity gas use

can be mounted on live line via ‘hot tap’ method

Dimensional drawing

Detailed specification and ordering information: see next pageThermo Measurement reserves the right to alter specifications without notice

Features

ISSUE: 5300/MAR2001/US

Page 2: Insertion Turbine Flowmeter Series 5300 - Gilson EngFlow Automation Turbine Accessory Kits AKS Insertion turbine accessory kit Safe area Explosion operation proof Signal output 100

SpecificationFlowmeter:Linearity: (Liquids) ±2% of reading over

average, dependent on processapplications

(Gases) ±2% of reading at specified gas pressures

Repeatability: (Liquids) ±0.2%, dependent on application details

Pressure drop: Negligible

Process temperature: 0 to +300°F

Maximum pressure: 100psiG

Materials of construction: Insertion stem and rotor housing:

ANSI 304 stainless steel or similar

Turbine rotor: stainless steel ANSI 431

General:Hazardous area certification: FM approved enclosure Class 1,

Div 1, Groups B, C, D

Installation: Position where the effects of velocity profile distortion and swirling flow are minimized, ie not immediately downstream of bends, valves or other pipe fittings which can cause severe flow disturbances.

If the 5300 meter is to be installed by hot tapping the line through a full port gate valve then a 11/2"riser and gate valve must be used to allow sufficient clearance for the turbine.

If the 5300 is to be installed by only using a riser or pipe tee section then a 1" female NPTconnection can be used.

Outputs:Liquid: >20mV peak to peak at minimum

flow, typically 100mV peak-to-peakat 3ft/s

High velocity gas: >40mV peak to peak at minimum flow, typically 100mV peak-to-peakat 3ft/s

Low velocity gas: >40mV peak to peak at minimum flow, typically 100mV peak-to-peakat 3ft/s

Pre-amplifiers: see Accessory Kits on back page

4-20mA analog

SQ2 pulse pre-amplifiers

Electrical:Power supply: Not required for mV pulse

24Vdc loop for FDC1100

5-24Vdc on 3 wire system for SQ2

Termination: 2 pin Cannon as standard

Terminal block housed in conduit box

Screw terminals on pre-amplifiers

Cable entry: NPT if used with junction box

Page 3: Insertion Turbine Flowmeter Series 5300 - Gilson EngFlow Automation Turbine Accessory Kits AKS Insertion turbine accessory kit Safe area Explosion operation proof Signal output 100

Ordering InformationModel code format5300 Flow Automation Insertion Turbine Flowmeter

Fluid typeG2 GasL1 Liquid

Flow range ft/s (m/s)A 2 - 40 1 - 12 Liquid applications onlyB 6 - 60 2 - 12 Low velocity gas applications only

Body material0 304 stainless steel

Temperature rangeT1 0 to +300°F (-20 to +150°C)

Process connectionS1 Male NPT (1 inch)

Termination00 Flying leads, suitable for local indicator12 2 pin Cannon connector38 Explosion proof enclosure

CertificationS Non hazardous/safe area operationI Intrinsically safe (consult factory)7 FM Class 1, Div 1, Groups B, C, D

Example: 5300-G2-B-0-T1-S1-00-S

Flow Automation 5300 series insertion turbine flowmeter, low velocity gas application, 6-60ft/s flow range,stainless steel body, 0 to +300°F operation,1" male NPT process connection, flying leads suitable for localindicator, suitable for non-hazardous/safe area operation.

NOTE: TURN TO BACK PAGE FOR ACCESSORY KIT TO COMPLETE YOUR ORDER

Page 4: Insertion Turbine Flowmeter Series 5300 - Gilson EngFlow Automation Turbine Accessory Kits AKS Insertion turbine accessory kit Safe area Explosion operation proof Signal output 100

Thermo Electron CorporationKing’s WorthyWinchester, HampshireSO23 7QA, United Kingdom

Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]

Thermo Electron Corporation9303 W. Sam Houston Parkway SouthHoustonTexas77099 – 5298 USA

Tel: +1 (713) 272 0404Fax: +1 (713) 272 2273

Turbine Accessory KitsThermo Measurement manufactures a large range of accessory kits for use with Flow Automation turbine meters.

A description of the interface electronics is shown below, together with ordering information and certification guide.

Select from the information below, as shown in the example.

Example: AKS-215 Insertion turbine accessory kit, with local display with rate/totalizer indicator, battery powered

Note 1 - Use termination Code 38 on Ordering Information (p3)Note 2 - Use Termination Code 00

Ordering Information

Interface electronicsModel DescriptionFDC1100 4-20mA analog outputSQ2 5 volt pulse pre-amplifier

Flow Automation Turbine Accessory Kits

AKS Insertion turbine accessory kit Safe area Explosionoperation proof

Signal output100 Uncertified pickup with flying leads Yes No

(see Note 2)

215 Local display with rate/totalizer Yes Noindicator, battery powered (see Note 2)

216 Local display with rate/totalizer Yes Noindicator, 4-20mA output, loop powered (see Note 2)

217 Local display with rate/totalizer with Yes Noalarm, loop powered (see Note 2)

501 FM approved enclosure with terminal block Yes Yes

502 NPT stem with Cannon connector Yes No

503 FM approved enclosure with FDC1100 Yes Yes(see Note 1)

504 FM approved enclosure with SQ2 Yes Yespre-amplifier (see Note 1)

505 FM approved enclosure with rate/totalizer Yes Yes(see Note 1)

Page 5: Insertion Turbine Flowmeter Series 5300 - Gilson EngFlow Automation Turbine Accessory Kits AKS Insertion turbine accessory kit Safe area Explosion operation proof Signal output 100

Turbine Accessory KitsThermo Measurement manufactures a large range of accessory kits for use with Flow Automation turbine meters.

A description of the interface electronics is shown below, together with ordering information and certification guide.

Select from the information below, as shown in the example.

Ordering Information

A Thermo Electron business

Thermo Measurement LtdKing’s WorthyWinchester, HampshireSO23 7QA, United Kingdom

Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]

Thermo Measurement Ltd9303 W. Sam Houston Parkway SouthHoustonTexas77099 – 5298 USA

Tel: +1 (713) 272 2218Fax: +1 (713) 272 2214

Interface electronicsModel DescriptionFDC1100 4-20mA analogue output

A10 4-20mA current modulated square wave pulse pre-amplifier

Flow Automation Turbine Accessory KitsAKS Insertion turbine accessory kit Operation required in:

Signal output Safe area IS Ex d

100 Uncertified pickup to suit customer’s Yes No Nolocal display

101 Uncertified enclosure with terminal block Yes No No

102 Uncertified enclosure with A10 pre-amplifier Yes No No103 Uncertified enclosure with FDC1100 Yes No No

frequency to current convertor

200 IS certified pickup to suit customer’s local Yes Dependent Nodisplay on display

201 IS certified pickup and terminal block Yes Yes No

202 IS certified A10 pre-amplifier Yes Yes No205 Local display with rate/totaliser indicator, Yes Yes No

10 point linearisation, battery powered

206 Local display with rate/totaliser indicator, Yes Yes No4-20mA output, 10 point linearisation, looppowered

207 Local display with rate/totaliser with Yes Yes No4-20mA output and alarm, 10 point linearisation, loop powered

301 Terminal block suitable for flame proof Yes No Yesenclosure (see Note 1)

302 Flame proof A10 pre-amplifier (see Note 1) Yes No Yes

303 Flame proof FDC1100 frequency to current Yes No Yesconvertor (see Note 1)

502 M25 stem with Cannon connector Yes No No

Note 1 - Use termination Code 37 on flowmeter Ordering Information

Insertion turbine accessory kit, with local display with rate/totaliser indicator, battery poweredExample: AKS-205