innovative solutions for aseptic processing
TRANSCRIPT
InnovatIve solutIons
for asePtIc ProcessIng
InnovatIve solutIons
for asePtIc ProcessIng
IntroductIonCAD Clean & Aseptic Design: One idea, many solutions.
The CAD valve range is the key tool to help you easily satisfy critical aseptic processing criteria.Frustrated with poor performing hygienic valves, aseptic process designers are asking for equipment to be able to fulfil the most stringent requirements of CIP and SIP. CAD valves are designed to answer these demands with properly designed process configurations upstream, downstream and around process vessels. The family of CAD valves offer designers a wide range of engineered solutions in order to realize compact designs, free of dead legs, with minimal solution hold up. Processing with CAD valves, which are constructed of 2 materials only: EN 1.4435-BN2 and PTFE USP Class VI-121°, will provide you an efficient process system, simple, reliable, and easy to validate.
CAD valves benefits:- Optimized CIP-SIP Cycles- No unused portions- Flush flow design- Easy process Validation- Wide range of design possibilities to meet unique applications- Extensive technical documentation for Validation
Valve design range: the CAD family valve range is extensive. Our specialists in process design will support you in selecting the appropriate type. We can also help you optimize your solution preparation system in order to achieve a design free of unused portion piping and zero dead legs, with minimal product hold up in a compact design with fast and effective CIP and SIP cycles.
Standard preassembled valves: a variety of valve assemblies are available to speed up process construction. Point of use, bottom drain point, and others are available as standard products.
Tailored valves and valves assembly: if required, our specialists are able to quickly design, build and delivery special valves or assemblies.
Support: this guideline will help you with the correct valve selection and suggest alternative solutions according to your needs. The goal is to improve general performance in terms of effective cleaning (CIP), sterilizations (SIP) and full drainability. For additional information or support feel free to contact us at [email protected] or call the nearest Official CAD Distributor by looking at our website: www.rattiinox.com/en/contact-us
Philic
Air
Vacuum UnitTemperature ControlUnit
Loop sampling
B B
A
A
V09
V13
V13
CD02
01
01
01
01
TR
TT
TC
TE
CIP-SIP Unit of TK2
25.4
x1,6
5
25.4
x1,6
5
19.0
5x1,
65
19.0
5x1,
65
19.0
5x1,
65
19.0
5x1,
65
19.0
5x1,
65
19.0
5x1,
65
19.0
5x1,
65
B
AV63
16
16
16
AS
TM A
270
- 19
.05x
1,65
FX ??Spool piece
V25
5F
Millibarrier
TE16
TT
TC
TR
PV40PV40
BA
CD14
FILLING
14
14
14
13
1313
11
11
11
10
10
10
09
09
09
08
08
0804
04
04
0403
03
03
V66
V61B
V06
B
B
V09
Accessorio Facoltativo
FacoltativoAccessorio
Holding tank TK2transfer line di TK2
CIP-SIP Unit of TK1
Preparation vessel
FX105
FX106
Vent
PI
06TE
06
06
06
TR
TC
TT
TE
TT
TE
TT
TC
TR11
PTFE0.2um
Arr
ivo
prod
otto
da
TK1
0.2um
V65
HV107
04IP
V62
03IP
PI107
F7
CD13
TE19
TT19
TC19
TR19
CD15
PT04
TE
TSL
TR
TT
10
Aria C.
V48AV33 V34
CIP
TE
14
TT
CD12
TR
TC
F2B
HV105
F2A
PI105
F5
V47
WIT02
V45
V46
CD11
V72V71
A
Sampling point
CD10
NAS1
V30
V31
V28
FT01
FC01
01FR
CIP
Vxx
V00
V07
19.0
5x1,
65
19.0
5x1,
65
TE
TR07TC07
TT07
07
CD05
V21
V19
WIT02V20
F1A
V08
NAS1
CD09CD04CD03
SteamPure Steam
PureVentVent
CD-TK3 38,1x1,65
CD-TK2 38,1x1,65
Vent
CD08CD01
F6A
F5BF5A
F2BF2AF1B
25.4x1,65 EP
ZSPSE2
PSE1ZS
FFT
SIR01
ST01
SC01
TT TE
TC
TR
01
01
01
01
V28
FX08
WIT03V29
F2
PI102
HV102
FX03
WIT01
01AR
AI01
ZSL11C
V24
F3
103PI
0.2um
HV103
IP02
IP01
19.0
5x1,
65
0.2um
0.2um
PI1044
HV104
F4
F1
V04
02TR
02TSL
02PSL
02PT
PC02
PR02
02WE
02WT
02WR
02WC
TT
TC12
12
12TE
WC01
WR01
WT01
01AI
pH
01PI
CIP
TR
TT
03TC
CD-TK3 38,1x1,65
WE01
HV101
01
Philic
A
09
PSE1PI
110
PSE2PI
111
0505TCTT
38,1
x1,6
5
38,1
x1,6
5
38,1
x1,6
5 E
P
38,1
x1,6
5
38,1
x1,6
5
CD-TK2 38,1x1,65
CD-TK1 38,1x1,65
25.4
x1,6
5
25.4
x1,6
5
25.4
x1,6
5
25.4
x1,6
525.4
x1,6
5
25.4
x1,6
5 E
P
25.4
x1,6
5
25.4
x1,6
5 E
P
CIP
13TR TC
TR
TC
TT
02PI
02PC
08TRTR
TCTC
TTTT
PC01
PT
02TE
02TT
FR01
01FC
01
V43
B
A
V36
B
V11
V18V17
B
B
V10
TE04TE TE
A
FillingRoom
WFI85°C
N23.5 bar
N2
N20.5 bar
WFI
3.5 bar
for CO2 stripping during preparation
85°C/4°C6 bar
V42
HOLDINGTANK
DT2
PT02
V38
V35FX05
V41
TK2
V40
FX07
FX06
V39
V44V37
V26
V25
PTFE
TE
V27
CD07
V23V22
DT1
A
TE05
V14 V15
MIX01
TK1
FX04V16
01AT
CD06
FX01
FT
FX02
PI101
V05V02 V03 V12
PREPARATION
V01
CD21
Accessorio Facoltativo
Accessorio Facoltativo
INNOVATIVE VALVE WITH ZERO DEAD LEGS
one Idea, ManY solutIons
www.rattiinox.com .05
cad equIvalent IsoMetrIc vIewThanks to the CAD philosophy and the wide product range, the use of elbows or tees can be drastically reduced.The final project results in a very compact design with less piping which improves system performance, cleanability, sterilization and overall efficiency.
conventIonal equIPMent IsoMetrIc vIewProjects realized with classic weir style membrane valves require a large number of elbows and tees. These fittings have been developed to allow for orbital welding, requiring extended pipe for this procedure. The final project often results in larger installations with some unused portions and dead legs, reducing the final efficiency and performance of the systems in terms of temperature distribution, drainability and cleanability.
IntroductIon IntroductIon
06. www.rattiinox.com www.rattiinox.com .07
classIc equIPMent P&IdTypical P&IDs use unified symbols to identify the valves and components in an installation. Weir style valve symbols identify only a small list of bodies which sometimes leave interpretation to the builders which can result in incorrect valve selection.
cad P&IdThanks to the wide CAD product range, it is possible identify immediately the required valve configuration, such as Shut off 90°, Shut Off 180°, Flow Through, On Pipe, etc... CAD valves have their own symbols. Our process experts will help you in the conversion from your classic P&ID to the CAD P&ID.
IntroductIon IntroductIon
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV03
PV01
WFI
PV02 PV
07B
PV05
PV06
HV02
PV04
HV01
PI01
PV07A
PV18
PV17
PV08B
PV08A
PS N2
Prod.
Vent
PV09A
PV09B PI
04
PV10
PV15
PV11
PV14A
PV14B
CD05
PV13
TE02
MIX01
Sampling
PV20PV
19
PV12A
PV12B
TE01
PV16
PV21
PV22
PV23
Lamp
CD04
CD03
CD01
CD02
08. www.rattiinox.com www.rattiinox.com .09
features analysis: asYMPtotIc sealsTwo main factors affecting aseptic processing are CIP (Cleaning In Place) and temperature distribution for an effective SIP (Sterilization In Place). To achieve efficient and effective cleaning in place, a turbulent flow is required. The key point to achieving a turbulent flow is to avoid asymptotic closures.
cad design: free froM asYMPtotIc sealsBioprocessing professionals more than ever require equipment able to efficiently fulfil the stringent requirements of CIP and SIP. The flush flow internal design of the CAD Valve, which is free from asymptotic closures and dead legs, is a key tool enabling you to guarantee critical criteria are easily satisfied.
IntroductIon IntroductIon
A=Zero
A3
A2
A1
Seal
10. www.rattiinox.com www.rattiinox.com .11
features analysis: dIaPhragMWeir-style EPDM+PTFE backing cushion membranes, can have low resistance against vacuum resulting in a short life during SIP processes.
CAD valves were engineered from the beginning to address the most stringent requirements in terms of chemical compatibility and high temperature resistance.For this reason the CAD valve was developed at the outset with solid compound PTFE Diaphragms without an EPDM cushion.This design has proven advantages in diaphragm life, resistance to steam and overall chemical resistance. CAD diaphragms are also able to run under vacuum conditions, required to speed-up drying processes after SIP cycles. The engineered self-centering system allows the possibility to disassemble and reassemble the same diaphragm for inspection purpose, avoiding leakage at sealing points, typical of other PTFE diaphragms.
features analysis: free forM bodY desIgnValve with a straight body design require the use of additional piping such as elbows and tees during piping assembling which increase the distance between the inlet of the flow to the outlet of the valve.
Thanks to the radial design and the Smart Manufacturing System, each CAD Valve will follow all requirements in terms of single or multiple connections on the body reducing or eliminating additional fittings such as elbows and tees. This results in a very compact but serviceable design by reducing the number of component weldings and useless piping. The CAD product range is very extensive. Our process experts will help you choose the correct design to improve the performance of your systems. Full adaptability to engineering design is achieved: one idea, many solutions.
ONE SEALINGPOINT&SELFCENTERINGSYSTEM
PRESSURECONTRASTSYSTEM
SMALLCLOSUREAREA 90°
90°
IntroductIon IntroductIon
Example of conventional designExample of conventional design CAD designCAD design
12. www.rattiinox.com www.rattiinox.com .13
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Process valves: shut off 90
Example of conventional design
Standard CAD Valve body configurations examples: coaxial, eccentric, tangential.
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
The typical straight design of membrane valves are commonly used for hygienic industrial applications but their internal design, with asymptotic closures, will always have two long dead legs on the valve entrance and outlet. This is an important feature that may reduce performance of aseptic processing systems.
CAD SOluTiOn. Radial design drastically reduces the distance between the inlet of the valve and the sealing area. During the assembly of a Shut-Off 90° valve, the distance between the valve inlet and the outlet is reduced and drainability is automatically improved. The internal design, free from asymptotic closure, improves the speed of CIP & SIP cycles while also avoiding in some cases disassembly for manual internal cleaning.
CAD design
Internal design free from
asymptotic closure
Short distance between the inlet and the sealing area
14. www.rattiinox.com www.rattiinox.com .15
Process valves: flow through 180During the development of manifolds, tee fittings are usually needed, but this design will add one Dead-Leg for each valveconnected. Dead-Legs result in reduced performances of ClP and SIP steps, incorrect temperature distribution, air pocket, etc...
CAD SOluTiOn. The Flow Through design allows the flowing medium to cross and circulate inside the valve and inner part of thediaphragm. This area is always under flow, thus avoiding stagnet product inside the valve body.Thanks to the flush flow design of Flow-Through valves, the Dead-Leg between the closure area and the manifold main pipeline is a real ZERO Dead-Leg, not 3xD or 1,5xD. This design offers a great benefit in terms of cleaning and sterilization in CIP andSIP cycles. The typical body configuration body is 180° in/out. Also available as a standard design is the Flow-Through 90° valve as well as with tangential connections to avoid the use of elbows which result in product hold up.
Example of conventional design CAD design
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Standard CAD Valve body configuration examples: 180°, 90°.
Internal design free from
asymptotic closure
Flush flowdesign
Short distance between the inlet and the sealing area
16. www.rattiinox.com www.rattiinox.com .17
bottoM tank valves
CAD design
Tank outlet valves of the weir design have significant limitations due to the fact that to achieve this application a larger diameter welding plate is needed. According to PED rules the thickness of the bottom dish needs to be increased to accommodate the larger cut out. In addition, the closure area has to be moved to a lower position to be able to accept the membrane sealing which results in a pocket on the internal side of the vessel. This pocket makes homogeneous mixing problematic and typically not acceptable for bioreactors.
CAD SOluTiOn. CAD Bottom Tank Valves have been designed to follow the most stringent requirements for pharmaceutical vessels. Most importantly the closure area is positioned as close as possible to the internal side on the vessel without creating a pocket.In addition, the conical part of the valve inlet is open to the turbulence of the mixing unit reducing to a minimum the risk of deposits of suspensions in this area. The welding plate diameter can be minimized, allowing designers to reduce the dish thickness as much as possible according to PED rules.
Example of conventional design
Standard CAD Valve body configuration examples: shut-off, flow through 90°, flow through 180°.
Small welding plate diameter
Internal design free from
asymptotic closure
Valve inlet open to the turbolence
of mixing unit
18. www.rattiinox.com www.rattiinox.com .19
bottoM tank valves + satellIteCAD SOluTiOn. Important to aseptic processing design is the possible addition of satellite valves on a CAD Bottom TankValve. This feature allows the possibility to clean and sterilize downstream of the vessel before transfer of the product inside thevessel taking advantage of the ability to CIP downstream of vessel without loading CIP media inside the vessel. CAD Valves used in satellite applications are typically eccentric or eccentric as well as tangential. Eccentric valves reduce the ratioin correspondence of the entrance of the satellite valve on the bottom valve, reducing the dead-leg, allowing also the possibilityto use larger satellite valve sizes to improve the quantity of water flow on CIP cycles inside the CAD Bottom Tank Valves.Thanks to the eccentric & tangential solution, the minimum distance required between the lower part of the vessel and the floorcan be reduced, saving space against the room ceiling, and avoiding again the use of elbows at the entrance of the satellite valve.
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Small welding plate diameter
Internal design free from
asymptotic closure
Reduced ratioin correspondence
to the entrance of satellite valve
Valve inlet open to the turbolence
of mixing unit
Tangential connection, no elbow needed
Internal design
free from asymptotic
closure
20. www.rattiinox.com www.rattiinox.com .21
bottoM tank valves for jacketed vesselsUsually vessels and fermenters for biotech applications require full body insulation to keep the internal side at a specific controlled temperature. Typically the jacket of the vessel on the lower side covers only a portion of the vessel bottom, but not the tank outlet valve, leaving the lower side of the vessel at a non-controlled temperature. This may result in a fermenting process that is hard to control or out of control.
CAD SOluTiOn. Thanks to the CAD Bottom Tank Extended Valve Bodies, it is possible to weld the jacket over the valve body. The result is the valve and the entire vessel bottom can be insulated, eliminating a heat sink. This will result in a fully controlled temperature in the lower part of the vessel improving fermentation efficiency as well as use in MAB cryogenic storage vessels where maintaining vessel temperature is critical.
Example of conventional design CAD design
Small welding plate diameter
Internal design free from asymptotic closure
Extended welding area for jacket
Valve inlet open to the turbolence
of mixing unit
CAD standard bodies configurations examples: shut-off, flow through 90°, flow through 180°.
22. www.rattiinox.com www.rattiinox.com .23
bottoM tank valves for jacketed vessels + satellIteCAD SOluTiOn. The advantage for aseptic processing to fully control vessel temperature and allow for ease of downstream CIP/SIP can also be achieved on the lower part of bioreactors and other critical vessels. Thanks to the wide range of configurations of the CAD valves there is the possibility to add a satellite valve for downstream cleaning and sterilization of fully jacketed vessels.
Small welding plate diameter
Straight outlet design, no elbow needed
Extended welding area for jacket
Valve inlet open to the turbolence
of mixing unit
Internal design free from
asymptotic closure
Reduced ratioin correspondence
of the entrance of satellite valve
Tangential connection, no elbow needed
Internal design
free from asymptotic
closure
24. www.rattiinox.com www.rattiinox.com .25
tank weldable valves
Example of conventional design
Adding a valve on the top or on the side of a vessel requires a connection. Adding a connection such as a Tri-Clamp may result in a dead-leg that will may have problems in terms of internal cleaning and sterilization. Using CADCON welding plates there is the possibility to reduce the distance between the internal side of the vessel and the valve closure area. Sometimes, this is not still enough...
CAD SOluTiOn. Thanks to the CAD Tank Weldable Valves, the distance between the internal side of the vessel and the valveclosure area can be drastically reduced. This will have a great effect on CIP/SIP cycles of the vessel, by avoiding any dead legs.On request, the welding area of CAD Tank Weldable Valve can be machined according to the radius of the vessel, moving the valveclosure area nearest to the internal side of the vessel. The manufacturing of the vessel will be easier and cleanability will beimproved avoiding any disassembling operation.
CAD design
Standard CAD Valve body configuration examples: shut-off, flow through 90°, flow through 180°, with coaxial or tangential connections.
Short distance between the inlet
and the sealing area
Internal design free from asymptotic closure
Rounded milled welding plate
according to the radius of the vessel
26. www.rattiinox.com www.rattiinox.com .27
tc connectable - toP MountIng
Example of conventional design
Each connection on the top of a vessel is a cleaning problem. Each connection requires additional attention during cleaning due to the fact that it has to be cleaned by the spray ball positioned inside the vessel. More connections equal more difficulty cleaning by CIP. If closure areas of valves mounted over the vessel cannot be reached by the spray balls, CIP will not be achieved and disassembling will be required for additional cleaning. Welding of Tri-Clamp ferrules and connecting a valve with a straight design, moves the closure area farther from the top of the vessel. Welding of a CADCON instead of a Tri-Clamp will reduce this neck, putting the Tri-Clamp sealing point in correspondence with the internal side of the vessel.
CAD SOluTiOn. The easy solution to reduce dead legs on the top of the vessels is to transfer the valve closure area as close aspossible to the internal side of the vessel. This is the most important reason for development of the CAD TC Connectable valves.A wide product range based on all CAD valve designs with Tri-Clamp connections already machined on the valve body isstandard. These valves are ready to be connected to a CADCON connection which offers designers and operators completeflexibility. The valves are designed to avoid interference between the valve body and the bolts over the flange. For each valve sizethere are available many different valve designs such as Shut-Off, Flow Through, etc..., even with different Tri-Clamp sizes.
CAD design
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Short distance between the inlet
and the sealing area
Internal design free from
asymptotic closure
Wide range of Tri-Clamp connections available as standard for each CAD valve size
Standard CAD Valve body configuration examples: shut-off, flow through 90°, flow through 180°.
28. www.rattiinox.com www.rattiinox.com .29
extended tc connectable lateral MountIng
Example of conventional design
Aseptic processing is like a chain: each component has to work properly. Even with one of the components not working properlywill result in a final failure of the entire system. In case of a lateral connection on a vessel, any additional connections may cause acleaning problem. Elimination or reduction of dead legs will improve cleanability and sterilization of the system. Welding of a noncleanable or a long connection will compromise the entire process.
CAD SOluTiOn. CAD Extended TC Connectable valves, connected on a CADCON, will put the valve closure area very close to the internal side of the vessel, achieving the best condition to improve cleanability and sterilization of the vessel with additional benefit for all the process. Also Extended TC Connectable valves are available on all the CAD range design: Shut-Off, Flow Through 90, Flow Through 180, etc...
CAD design
Standard CAD Valve body configuration examples: shut-off, flow through 90°, flow through 180°.
Real Zero Dead Leg design
Internal design free from asymptotic closure
Fully drainable internal design
30. www.rattiinox.com www.rattiinox.com .31
dIvertIng valves
Example of conventional design
During Aseptic Processing it is often the case that the flowing media, whether product, CIP chemicals, clean steam or sterile gases,has to be properly managed through the system. Simply welding or connecting via Tri-Clamp two valves on a tee piece will result in2 main negative effects: dead-legs and unused portions. Either situation can limit the drainability and thus the cleanability andsterilization of the system. This also increases the general dimensions and overall volume of the installation which can also reduceperformance as well as increase maintenance costs.
CAD SOluTiOn. CAD Diverting valves are the solution when the flow path has to managed in different directions. The distancebetween the two closure areas are equal to the internal diameter of the common inlet pipe, achieving a very compact design, free oftee pieces or junctions. CAD Diverting valves are available as standard with 90° outlets or inlet which eliminates the need for manyelbows. Several combinations are available in the catalog as standard but additional customized designs may be manufacturedaccording the demands of the process. Vertical or horizontal installation is not a problem. In the case where a horizontal installation is preferred, CAD Diverting valves are available with tangential outlets in order to achieve complete drainability of the valves.Two diverting valve connected between the common part is a typical configuration of a “Block and Bleed” assembly.
CAD design
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Standard CAD Valve body configuration examples: parallel, opposite,coaxial, tangential, 180°, 90°.
Internal design freefrom asymptotic
closure
Internal design free from asymptotic closure
Minimized distance between diaphragms
32. www.rattiinox.com www.rattiinox.com .33
valves on PIPe - coaxIal
Example of conventional design
Take-off or feed-in of a fluid on a pipeline is an additional key point because this requires additional connections on the main pipewith a dedicated valve. In this case the distance between the inner pipe and closure area of the additional valve has to be reducedas much possible. Adding a tee piece will move this closure area farther from the main pipeline. This reduces the efficiency of theCIP or effect of SIP by creating an air pocket. To improve cleaning and reduce retention areas, an internal valve design free fromasymptotic closures is an additional key point to achieving turbulent flow.
CAD SOluTiOn. CAD Coaxial On Pipe Valves, respond to this requirement by putting the valve closure area in correspondence with the pipeline; like a finger that closes a hole on the side of a pipe: a real Zero Dead Leg design. Ideal for feed-in pipe, take-off or sampling from a pipe. The most stringent applications for WFI, PW loop or PS distribution piping can be easily managed. These valves are available in Shut-Off or Flow Through designs and also with additional satellite valves for downstream sterilization. If required, full drainability of the piping system can be achieved by connecting the valve in a vertical upside down orientation.
CAD design
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Standard CAD Valve body configuration examples: shut-off, flow through, shut-off + satellite, double opposite shut-off.
Short distance between the inlet
and the sealing area
Compact design
Internal design free from asymptotic closure
34. www.rattiinox.com www.rattiinox.com .35
valves on PIPe - tangentIal closure
Example of conventional design
CAD SOluTiOn. CAD Tangential On Pipe Valves, are the answer where full drainability of the main pipeline is required in ahorizontal assembly of the valve. In this design, the valve inlet which is always in close correspondence to the valve closure point, is tangential to the lower internal level of the pipe. This allows for the complete draining of the main pipe down to the last drop. For easier connection and space saving, the valve outlet will be vertical, compared to valves with additional elbows at the outlet. As with the case of most CAD solutions, it is available in the full product range: different valve sizes for each pipeline, Shut-Off, Flow Through, with or without satellite for downstream sterilization. Ideal for feed-in pipe, take-off or sampling from a pipe.CAD valves are able to fulfill all stringent applications for WFI and PW distribution loops.
CAD design
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Standard CAD Valve body configuration examples: shut-off tang. on pipe, shut-off tang. on pipe + satellite, flow through tang. on pipe.
Short distance between the inlet
and the sealing area
Additional connection
for satellite valves on flow through
valvesInternal design free from asymptotic closure
Straight outlet for optimal drainability
36. www.rattiinox.com www.rattiinox.com .37
Process asseMblY: PoInt of use Typically complete point of use valves on pharmaceutical water loops for aseptic processing are comprised of a main user valve,a sampling valve and two additional satellite valves for downstream sterilization of both valves. Welding 4 valves together on a looprequires complex and expensive work that has to be done during the installation of the piping. This job usually has to be done withorbital welding machines to assure good weld quality. Components developed for orbital welding machines require long butt-weldends which increases system volume. The positioning and orientation of the valves during installation can be very difficult and timeconsuming.
CAD SOluTiOn. CAD Point of Use Assemblies are the answer to the highest demands in terms of efficiency and compactdesign. Using precision machining capabillities, all the required valves can be machined from a single block, thus keeping thesystem’s dimension to the absolute minimum. During the installation, only two connections have to be made to the main pipeline.The block can be delivered with ready to work steam Tri-Clamped inlets and outlets, saving hours of job site installation andachieving a level of quality not possible in the field. Several configurations are available. Our process experts will help you in thecorrect configuration according to your needs.
Standard CAD Point of Use Valve examples: point of use valve + satellite & sampling valve + satellite, extended point of use + flow through valve + shut off, all available on several dimensions and configurations.
Satellite flow through valve
for nitrogen or sterile air
Real Zero Dead Leg design
Satellite shut-off valve for steam
38. www.rattiinox.com www.rattiinox.com .39
Process asseMblY: bottoM PoInt asseMblIes Typical bottom point drains in pharmaceutical installations for aseptic processing are composed of a large CIP drain valve and asmaller valve for the condensate drain. These valves may have a common inlet, but the two outlets have to be separated and workalternately according to the upper running process: CIP or SIP. An additional connection has to be added and this connectionshould be as close as possible to the closure areas of the two valves in order to connect the temperature transmitter. This closecoupling allows accurate detection of the temperature level on the lower part of the installation to be sure that during SIP cycles,the entire system is running at the required temperature. Welding of all the components of this system together require repetitiveand sometimes complex work due to the fact that the height available is often very limited.
CAD SOluTiOn. CAD Bottom Point Assemblies are the answer to this need. Two different designs are available according tothe requested steam trap. Both types are available in two main sizes: 3/4” valve for CIP drain valve + 1/2” for condensate drainvalve or 1” CIP drain +1/2” condensate drain. Both systems have all required Tri-Clamp connections and can be connected tothe installation in few minutes, saving hours of on-site work and speeding the finishing of the installation. The CAD Bottom Pointassembly will result in a very compact design with a final quality not possible when compared to the same work done with typicaltools available during on-site or skid fabrication.
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Smaller valve for condensate
drain (SIP)Larger valve for CIP drain
Waste collector connection
Reversible connections: line in or temperature
transmitter
Standard CAD Bottom Point of Use assembly examples: 2 different configurations, both available on 2 dimensions, 3/4”+1/2” or 1”+1/2”.
40. www.rattiinox.com www.rattiinox.com .41
Process asseMblY: deeP tube sPraY ball Typical pharmaceutical vessels require several connections on the top of the vessel and each for different purpose: product inlet,ventilation filter, water feed inlet, vaccum disk breaker, spray balls, sparger, etc... Unfortunately each connection presents aproblem in terms of cleaning. For this reason, many times two spray balls are inserted inside the vessel. Managing this largenumber of connections, typically with welded ferrules and valves set far back from the inner tank surface requires frequentmaintenance operations for cleaning reasons.
CAD SOluTiOn. Following the CAD philosophy, by adding the CAD Deep Tube Spray Ball, the total number of connections on thetop dish can be drastically reduced. This simplfies design and improves the cleanability of the vessel. Tank filling, SIP, CIP and gasbubbling can be done with just one tool, using only one connection.
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
PV13
HV01
TE02TE01
PV03
PV01
WFI
PV02
PV07B
PV05
HV02
PI01
PV07A
PV18PV17 PV20PV19
PV21
PS N2
Sampling
Vent
Prod.
PV06
PV04
PV08A
PV08B PV09A
PV14APV14B
CD05CD03
PV12BPV12A
PV09B
LAMP
CD01 CD02 CD04
MIX01PV16 PV15
PV11PV10PI04
Additional head for gas bubbling
Only one inlet for all utilities
Tailored overall length
Customized spray ball machined from solid compound
2 versions, both available in several dimensions: 2 functions for feed in/SIP + CIP or 3 functions for feed in/SIP + CIP + gas bubbling.
42. www.rattiinox.com www.rattiinox.com .43
actuatorsThe most stringent demands in aseptic processing typically require the use of stainless steel and PTFE due to almost universalcompatibility. During external cleaning process, plastic handles can be damaged. Plastic pneumatic actuators are large comparedto what is possible with a stainless actuator. During SIP operations the heat can compromise the functionality of these systems.Also position detecting sensors on actuators made of plastics have limited operating range in terms of temperature resistance.
CAD SOluTiOn. CAD manual actuators are made from stainless steel with PTFE handles and are fully autoclaveable. Pneumaticactuators are made of stainless steel. CAD Double Position Sensors are made from stainless steel and are fully programmablewithout mechanical adjustment via PLC or via the CAD Programmer. Two kinds of extended handles are available for bottom tankvalves and for both types the Double Position Sensor can be connected. Stainless steel
manual actuator
Anti-seizing coated stainless steel
PTFE hand knob
Stainless steel programmable double position sensor
Stainless steel pneumatic actuator
Anti-seizing coated stainless steel
CAD actuators: manual straight, manual 90° short or extended, pneumatic NC, NO, or double effect, modulating.
44. www.rattiinox.com www.rattiinox.com .45
dIaPhragMsFor some applications a standard radial valve is still not enough to achieve closures with a zero dead leg. For these special applications, such as cryogenic vessels, fully jacketed vessels and pipe take-off applications the potential dead legs could reduce performance during SIP and CIP cycles.
CAD SOluTiOn. From its engineering birth, CAD diaphragms have been developed for all sizes valves, from half inch up to four inch, and in two lengths: short and extended. Thanks to this idea, dead legs can now be eliminated in places where it hasnot been possible before today. PTFE USP
Class VI-121°C
CAD diaphtagms: short or extended, both available from 1/2” up to 4”
PTFE USP Class VI-121°C
Stainless steel support
Precision machined
Precision machined
Stainless steel supportQuick change
system
Quick change system
46. www.rattiinox.com www.rattiinox.com .47
uPgradeDuring the design and manufacturing of a new installation, reduction of the external dimensions as well as the internal volume should be a priority in order to optimize the performance of the entire system. The CAD valve range has been engineered to allow designers of modern aseptic process systems to achieve a minimum distance between actuators, often just few millimeters.
CAD SOluTiOn. For applications, such as at the outlet of bottom tank valves or for an instrument connection, an elbow with TC connection or long butt weld ends for orbital welding may be needed. For this reason, a wide product range of additional high quality connections are available that can be ordered to match your specifications: straight, 45°, 90°, butt-weld or Tri-Clamp. This will result in quality improvement and time savings.
CAD upgrades: straight, 45°, 90°, butt-weld ends or Tri-Clamp, all available from 1/2” up to 4”
rattiinox s.r.l Via Mara, 44 22066 Mariano comense (como) Italy
t +39.031.3551263 f +39.031.3554509www.rattiinox.com [email protected]
Contacto en España y Portugal:
Juan Solá