Innovations in ICP Sample Introduction

Jerry Dulude, Glass Expansion, Inc.

4 Barlows Landing Rd.

Pocasset, MA

Page 2: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Summary of Discussion

Low Flow Nebulizers Helix O’ring-free Spray Chambers New Internal Standard Kit Niagara Rapid Rinse Accessory

Innovations in Sample Introduction

Page 3: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Applications of Low-Flow Nebulizers

Limited sample volumes Volatile samples Expensive waste disposal ICP-MS-LC interface

Low-Flow Nebulizers

Page 4: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Range of Low-Flow Nebulizers

MicroMist- Concentric glass nebulizer 0.05 to 0.6 ml/min

PolyCon- Concentric polyimide nebulizer 0.05 to 0.6ml/min

OpalMist- Concentric PFA nebulizer 0.01 to 0.6ml/min

Low-Flow Nebulizers

Page 5: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Transport Efficiency vs. Uptake

%EFFICIENCY

UPTAKE RATE (ML/MIN)

Indirect drain collection method

Low-Flow Nebulizers

Page 6: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Tertiary Flow Rate vs. Uptake

05

101520253035404550

0.03 0.11 0.27 0.5 0.61 1.4 2.1

uptake rate (ml/min)

ul/min

Tertiary Flow Rate (ul/min)

Low-Flow Nebulizers

Page 7: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Corroboration of Tertiary Flow Rates

Uptake rate

(ml/min)

Indirect Method

(mg/min)

Direct Method*

(mg/min)

0.03 15 14

0.11 23 21

Todoli, Hernandis, Canals, and Mermet, JAAS, 1999, 14, 1289-1295Using GE MicroMist nebulizer with U-tube absorption for measurement

Low-Flow Nebulizers

Page 8: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Primary Aerosol Size Distribution Comparison

20

60

100

D32 = 7.1

Nebulizer Gas Flow Rate = 1.0 L/Min Solution Uptake Rate = Natural Aspiration

MicroMist (0.03ml/min)

Diameter (m)10 20 30 40 50 600

D32 = 17.2

Conikal (2ml/min)

20

60

100

No

rmal

ized

Co

un

t

No

rmal

ized

Vo

lum

e

Diameter (m)10 20 30 40 500 60

Low-Flow Nebulizers

Page 9: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Tertiary Aerosol Size Distribution Comparison

No

rmal

ized

Co

un

t

Nebulizer Gas Flow Rate = 1.0 L/Min Solution Uptake Rate = Natural Aspiration

Conikal (2ml/min)

20

60

100D32 = 4.9

Diameter (m)

20

60

100D32 = 5.0

MicroMist (0.03ml/min)

10 20 40300 50

Baffled Cyclonic Spray Chamber

Low-Flow Nebulizers

Page 10: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

New Micro-Flow OpalMist

All PFA construction Natural uptake rate of 0.010 ml/min Ultra-high purity applications Ideal for micro samples down to 20 ul volume

Low-Flow Nebulizers

Page 11: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Cyclonic Spray ChambersAdvances in Nebulizer Installation

1984 1993

1996

Helix O’ring free spray chamber

Page 12: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Helix O'ring-Free Spray Chamber

Helix O’ring free spray chamber

Reduced carryover

Faster washout Higher purity Can stand up to

ketones and other solvents

Page 13: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

New Internal Standard KitBenefits of Internal Standardization

Compensate for physical interferences Viscosity Surface tension

Compensate for some chemical interferences High salts Mass related effects (ICP-MS)

Improve short term precision (simultaneous detectors)

Decrease long-term drift

Internal Standard Kit

Page 14: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

New Modular Internal Standard Kit

Internal Standard Kit

Page 15: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

IS Tee with Built-in Mixing Chamber

Internal Standard Kit

Page 16: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

New Flared-End Pump Tubing

The final building block of a totally modular system

Internal Standard Kit

Page 17: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

IS Schematic

Internal Standard Kit

Sample IS

Peri Pump

Page 18: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Niagara™ Rapid Rinse Accessory

Interfaces between ICP & Autosampler

Reduces required rinse time Programmable delay time Less than 8 inches high Includes adj. height stand

Rapid Rinse Accessory

Page 19: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

How Niagara Works

Rapid Rinse Accessory

Analysis Rinse

Page 20: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Niagara Time Saving (30 sec rinse)

Standard System With Niagara

Probe to sample 5 5

Uptake delay 15 15

Stabilization 10 10

Read 15 15

Probe to rinse 5 5

Rinse 30 5

Total (seconds) 80 55

Rapid Rinse Accessory

= Rinse steps

Page 21: Innovations in ICP Sample Introduction Jerry Dulude, Glass Expansion, Inc. 4 Barlows Landing Rd. Pocasset, MA

Glass Expansion

Summary

MicroMist nebulizers Efficient sample consumption Minimum waste generation

Helix spray chambers Eliminate o’ring maintenance and contamination Reduce carryover

Internal standard kit Improved accuracy without the work Easy & inexpensive modular replacement

Niagara Rapid Rinse Accessory More samples per hour Faster sample turnaround time

Rapid Rinse Accessory