industrial floodlight - 50-150 att id - villa lighting · industrial floodlight - 50-150 att id...

6
Approvals: Date: Page 1 of 6 Catalog Number: F Series (available MF Series: Marine Listed with optional hazardous location listing) Industrial Floodlight - 250-1500 watt HID Type: Job: G200-116/0614 © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires Series/Source - Wattage Options Finish (Factory Installed) Optics Voltage - - - Accessories (Field Installed) Overall Dimensions For Reference Only - Specifications Housing Die-cast aluminum housing shall be of marine-grade alloy with integrally cast, heat dissipating fins and a built-in aiming device. Dust-Tite housing shall be totally sealed from particulate entry. Standard unit constructed to IP65. MF Series, with Marine Listing, constructed to IP66. Optical Assembly High purity, 94% minimum reflectivity anodized aluminum reflectors, assembled without machine forming to assure maximum efficiency. Lamp Access A gasketed and removable socket assembly provides lamp access from below. Allows re-lamping without re-aiming. High temperature gasket provides positive, weatherproof seal. Lens Lens shall be 7/32” clear tempered glass to withstand thermal and physical shock, held in place by an aluminum (extruded: 400W, die-cast: 1000/1500W) lens frame and sealed to housing flange by one extruded, high temperature gasket and stainless steel screws to provide a sealed optical assembly. Socket Pre-wired grip-type mogul base socket. Glass end of the lamp is held in precise photometric alignment and protected from breakage by a Stabilux socket. Ballast SilentGuard high power factor ballast with reliable starting down to -29°C (-20°F) for Metal Halide, -34°C (-30°F) for Pulse Start Metal Halide, and -40°C (-40°F) for High Pressure Sodium. Ballast has Class H, 180°C (356°F) rated insulation. Crest factor does not exceed 1.8. Core and coil are encapsulated in a polyester resin compound (standard SilentGuard feature) with the capacitor located outside the encapsulation for ease of maintenance. Ballast components are enclosed in a drawn aluminum container. The fixture and ballast are arranged as separate but integral components. Mounting Standard cast aluminum ballast base provides integral mastfitter, suitable for mounting to a 2-3/8” O.D. vertical tenon. Alternate mounting accessories available. Finish Standard finish shall be textured gray UltraClad polyester powder coating, 2.5 mil nominal thickness, electrostatically applied and oven cured. All components shall be thoroughly cleaned by a 5 stage pre-treatment process including iron phosphate bath and non-chromic acid etching stages, ensuring optimum performance characteristics. Other colors may be specified. Listings Standard unit is ETL/cETL listed to the UL 1598 standard, suitable for Wet Locations. Available ETL/cETL listed to the UL 1598A standard - Marine Listing option (MF Series). Available ETL/cETL listed to the UL 844 standard - Hazardous Location Listing available in the US (HAZ option for MF Series only, not available in Canada). The quality systems of this facility have been registered by UL to the ISO 9001 Series Standards. Warranty 7 Year Limited Warranty (Include M prefix to designate Marine Listed series) (Reflector / Distribution) D C A B E (20.32cm) 10.5” (1) (26.67cm) 4.5” (11.43cm) F 2-3/8” O.D. (6.03cm) Vertical Pipe Tenon (by others) 8.0” A B C D E F 25.5” 23.0” 7.3” 13.8” 9.5” 10.0” (64.77cm) (58.42cm) (18.42cm) (34.93cm) (24.13cm) (25.40cm) 400 Watt (max) and 1000W PS unit - 23” housing Note: 23” housing is standard for F series 1000W PS units with BT37 lamp for best lamp stability. 26” housing is required on MF series 1000W PS units with HAZ option (hazardous location listed). A B C D E F 27.5” 26.0” 9.3” 18.0” 13.3” 11.5” (69.85cm) (66.04cm) (23.50cm) (45.72cm) (33.66cm) (29.21cm) 1000-1500 Watt - 26” housing Exception: Standard F series 1000W PS unit with BT37 lamp requires 23” housing for socket stability. See note above. 1) With certain dimming options, height of ballast container increases to 14.5” (36.83 cm). Side View Front View EPA data shown on page 3. Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled ‘Contain Mercury’ and/or with the symbol ‘Hg’. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycle and disposal can be found at www.lamprecycle.org. Hg Weight: 66 lbs (29.9 kg)

Upload: vuduong

Post on 14-Jun-2018

233 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Approvals:

Date:Page 1 of 6

Catalog Number:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HIDType: Job:

G200-116/0614

© 2013 Koninklijke Philips Electronics N.V. All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires

Series/Source - Wattage Options Finish(Factory Installed)

Optics Voltage

- - -

Accessories(Field Installed)

Overall Dimensions For Reference Only

-

Specifications Housing

Die-cast aluminum housing shall be of marine-grade alloy with integrally cast, heat dissipating fins and a built-in aiming device. Dust-Tite housing shall be totally sealed from particulate entry. Standard unit constructed to IP65. MF Series, with Marine Listing, constructed to IP66.

Optical Assembly High purity, 94% minimum reflectivity anodized aluminum reflectors, assembled without machine forming to assure maximum efficiency.

Lamp Access A gasketed and removable socket assembly provides lamp access from below. Allows re-lamping without re-aiming. High temperature gasket provides positive, weatherproof seal.

Lens Lens shall be 7/32” clear tempered glass to withstand thermal and physical shock, held in place by an aluminum (extruded: 400W, die-cast: 1000/1500W) lens frame and sealed to housing flange by one extruded, high temperature gasket and stainless steel screws to provide a sealed optical assembly.

Socket Pre-wired grip-type mogul base socket. Glass end of the lamp is held in precise photometric alignment and protected from breakage by a Stabilux socket.

Ballast SilentGuard high power factor ballast with reliable starting down to -29°C (-20°F) for Metal Halide, -34°C (-30°F) for Pulse Start Metal Halide, and -40°C (-40°F) for High Pressure Sodium. Ballast has Class H, 180°C (356°F) rated insulation. Crest factor does not exceed 1.8. Core and coil are encapsulated in a polyester resin compound (standard SilentGuard feature) with the capacitor located outside the encapsulation for ease of maintenance. Ballast components are enclosed in a drawn aluminum container. The fixture and ballast are arranged as separate but integral components.

Mounting Standard cast aluminum ballast base provides integral mastfitter, suitable for mounting to a 2-3/8” O.D. vertical tenon. Alternate mounting accessories available.

Finish Standard finish shall be textured gray UltraClad polyester powder coating, 2.5 mil nominal thickness, electrostatically applied and oven cured. All components shall be thoroughly cleaned by a 5 stage pre-treatment process including iron phosphate bath and non-chromic acid etching stages, ensuring optimum performance characteristics. Other colors may be specified.

Listings Standard unit is ETL/cETL listed to the UL 1598 standard, suitable for Wet Locations. Available ETL/cETL listed to the UL 1598A standard - Marine Listing option (MF Series). Available ETL/cETL listed to the UL 844 standard - Hazardous Location Listing available in the US (HAZ option for MF Series only, not available in Canada).

The quality systems of this facility have been registered by UL to the ISO 9001 Series Standards.

Warranty7 Year Limited Warranty

(Include M prefix to designate Marine Listed series)

(Reflector / Distribution)

DC

AB

E

(20.32cm)

10.5” (1)

(26.67cm)

4.5”(11.43cm)

F

2-3/8” O.D.(6.03cm)

Vertical Pipe Tenon(by others)

8.0”

A B C D E F 25.5” 23.0” 7.3” 13.8” 9.5” 10.0” (64.77cm) (58.42cm) (18.42cm) (34.93cm) (24.13cm) (25.40cm)

400 Watt (max) and 1000W PS unit - 23” housingNote: 23” housing is standard for F series 1000W PS units with BT37 lamp for best lamp stability. 26” housing is required on MF series 1000W PS units with HAZ option (hazardous location listed).

A B C D E F 27.5” 26.0” 9.3” 18.0” 13.3” 11.5” (69.85cm) (66.04cm) (23.50cm) (45.72cm) (33.66cm) (29.21cm)

1000-1500 Watt - 26” housingException: Standard F series 1000W PS unit with BT37 lamp requires 23” housing for socket stability. See note above.

1) With certain dimming options, height of ballast container increases to 14.5” (36.83 cm).

Side View

Front View

EPA data shown on page 3.

Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled ‘Contain Mercury’ and/or with the symbol ‘Hg’. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycle and disposal can be found at www.lamprecycle.org.

Hg

Weight: 66 lbs (29.9 kg)

Page 2: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Page 2 of 6Type: Job:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HID

G200-116/0614

© 2013 Koninklijke Philips Electronics N.V. All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires

1) “M”prefixalongwithseriesdesignatesUL1598AMarineListedoptionwhichincludesadditionalMarineGradegasketing.Unitisspeciallyconstructedwithlowcoppercontentalloy(lessthan0.4%)forcorrosioncontrolinharshcoastalandindustrialenvironmentsorwherevermarinetypeunitsarerequired.MeetsU.S.CoastGuardspecificationsformarinetypeapplications.

2) Wattageslistedassumetheuseofclearlamps.Coatedlampsalsoavailablefor1000Wmetalhalide.

3) Foracceptableperformance,notepositionorientationspecificnatureofPulseStartLamps.OperationofPulseStartlampsinotherthanrecommendedburningpositions

mayresultinsignificantlyreducedperformance.ConsultfactorytodetermineifasuitablePulseStartLampisavailablefortheintendedapplication.

4) In1000WHPSunits,thestandardSOcordfromballasttoopticheadisreplacedwithflexconduit.Lessballastoptionsandaccessoriesarenotavailable.

5) AandBreflectorsareofSpecularMiro4aluminum;CandDreflectorsareofHammertoneMiro9aluminum.Curvesreflectcoatedlampperformance.

6) Allowsfieldselectionof120/208/240/277V.(No480V).Certainoptionsmayrequirevoltageselectionaswell.

7) SuitableforHPSinanyaimingposition.8) FusingnotavailableonMFseries(marinelisted)units.9) Remotemountballastsoptionsandaccessoriesarenot

availablewith1000WHPSoronMFseries(marinelisted)units.

10)AvailablewithBandDreflectorsonly.11)HAZlistingavailableintheUSonMFunitsonly,400Wand

1000Wonly.HAZlistingnotavailableinCanada

r M MarineTypeUL1598AFloodlight 1 r A Specular Reflector Wide

r B Specular Reflector Medium

r C Diffused Reflector VeryWide

r D Diffused Reflector Wide

r 120

r 208

r 240

r 277

r 347

r 480

r QV 6

Metal Halide 2

r FM-1000 r FM-1500

Pulse Start Metal Halide 3

r FP-250 r FP-350 r FP-400 r FP-1000 Standard unit with BT37 lamp uses 23” housing. HAZ unit requires 26” housing.

High Pressure Sodiumr FS-400 r FS-1000 4

Energy Indep

ende

nce

Secu

rity Act Compliant Pulse Start M

etal Halide

VoltageOptics (Reflector/Distribution) 5Series/Source-Wattage

Accessories (Ordered Separately)

r F-F1-KIT-(F) SingleFuseKit (120/277/347V)

r F-F2-KIT-(F) DoubleFuseKit (208/240/480V)

r MF-1-(F) 9 Mastfitter

r TH-1-(F) 9 LoweringAdapter (TenonHanger)

r HV-1-(F) 9 TrunionBase

r WB-1-(F) WallBracket

r WB-5-(F) WiringBox (usedwithWB-1& surfacemountedconduitfeed)

r PX-1-(F) Cross-ArmBracket

Options (Factory Installed) Finish

r BL 7 Bi-Level

r LQ Hot/ColdQuartzRestrike

r LQ40 Hot/ColdQuartzRestrike forColdWeatherstartsto -40°C(-40°F)

r F-F1 8 SingleFuse (120/277V)

r F-F2 8 DoubleFuse (208/240/480V)

r LB 9 LessBallast(remotemount ballast)

r CO 10 Cutoffoptics

r HAZ 11 HazardousLocationlisted

r 50HZ 50HzBallastoperation (consultfactory)

r TG Teflonbondedto glasslens

r PB(X) Pre-wiredballast (X) = SO cord length in feet:

3,6or10

r EPXY-CTD-WHT WhiteEpoxy coated

r EPXY-CTD-GR GrayEpoxy coated

r TGR Textured Gray

r TBK Textured Black

r TDB Textured Dark Bronze

r TSA Textured Satin Aluminum

r TWHT Textured White

r TGN Textured Green

r M(F) Marine Grade finish; Two-partepoxyprimerand

apolyurethanetopcoatespeciallysuitedformarineenvironmentsandcoastalapplications.

(F)=Specifycolor. Example: MWHT =

Marine Grade Whitefinish

Consult factory for color availability.

r SMB-400 9 Shock Mounting Bracket (23”housing)

r SMB-1000 9 Shock Mounting Bracket (26”housing)

r FB-1 FlatBaseMount

r PCM-1 Photocell Receptacle Mounting Bracket

r SK-40-(F) CutoffShield (23”housing)

r SK-100-(F) CutoffShield (26”housing)

r AL-4-F AuxiliaryPolymerLens(23”housing)

r AL-10-F AuxiliaryPolymerLens(26”housing)

r ALF-4-F-L/LENS-(F) AuxiliaryLensFrame(23”housing)

r ALF-10-F-L/LENS-(F) AuxiliaryLensFrame(26”housing)

r ALF-10-F-L/GLASS-LV8-(F) 26”LensFramewithlouver;

r LENS-ALF-F-4-GLASS-(color) ColoredLens(23”housing);(color) = lens color

r LENS-ALF-F-10-GLASS-(color) ColoredLens(26”housing);(color) = lens color

r PM-1 WoodPoleMountingKit(withoneU-arm)

r PM-2 WoodPoleMountingKit(withtwoU-arms)

r PM-3 WoodPoleMountingKit(withthreeU-arms)

r PM-4 WoodPoleMountingKit(withfourU-arms)

(F) = specify finish

Page 3: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Page 3 of 6Type: Job:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HID

G200-116/0614

© 2013 Koninklijke Philips Electronics N.V. All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires

Max Horizontal X Vertical Candle H x V 10% 50%Reflector Type Source Wattage Power NEMA FieldAngle BeamAngle

A SpecularWide MH coated 1000W 43,000 7x7 147°x140° 90°x49°

B SpecularMedium MH clear 1000W 249,000 3x4 38°x62° 14°x34° 1500W 351,000 3x4 38°x62° 14°x34°

MH coated 1000W 79,000 6x7 127°x133° 36°x44° PS clear 250W 52,000 3x4 38°x62° 14°x34° 400W 90,000 3x4 38°x62° 14°x34° 1000W 260,000 3x4 38°x62° 14°x34°

HPS clear 400W 117,000 3x4 39°x53° 15°x26° 1000W 236,000 5x5 88°x87° 13°x41°

C DiffusedVeryWide MH clear 1000W 58,000 7x6 137°x129° 83°x37° 1500W 82,000 7x6 137°x129° 83°x37°

MH coated 1000W 37,000 7x7 150°x144° 93°x55°

PS clear 250W 52,000 7x6 137°x129° 83°x37° 400W 90,000 7x6 137°x129° 83°x37° 1000W 260,000 7x6 137°x129° 83°x37°

HPS clear 400W 26,000 7x6 137°x125° 105°x35° 1000W 50,000 7x7 138°x135° 85°x58° D DiffusedWide MH clear 1000W 133,000 5x5 93°x76° 28°x36° 1500W 187,000 5x5 93°x76° 28°x36° MH coated 1000W 37,000 7x7 150°x144° 93°x55°

PS clear 250W 52,000 5x5 93°x76° 28°x36° 400W 90,000 5x5 93°x76° 28°x36° 1000W 260,000 5x5 93°x76° 28°x36°

HPS clear 400W 26,000 7x6 137°x125° 105°x35° 1000W 50,000 7x7 138°x135° 85°x58°

Beam Spread Data

1) TheFSeriescanaccommodateavarietyofotherwattagesandlamps.Consultfactory.

2) MH=MetalHalide,PS=PulseStartMetalHalide,HPS=HighPressureSodium.

3) AllballastsareCWA(ConstantWattageAutotransformer).

4) LERvaluesandefficienciesarenotpublished.SeeNEMAStandardLE-5B.

5) Intendedaimingandpossiblelamporientationrestrictionsshouldbeconsideredwhenselectingfloodlight.

Source Catalog Reflector Lamp .ies ANSI Line Current Line Type(1) Number Type Envelope File Name Code 120 / 208 / 240 / 277 / 480 Watts

Distribution Guide & Ballast Data 1,4,5

FM-1000 B BT56 fm100bss.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080 FM-1000 C BT56 fm100css.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080 MH FM-1000 D BT56 fm100dss.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080

Clear

FM-1500 B BT56 fm150bss.ies M48 14.0/8.0/7.1/6.1/3.5 1625

Lamps FM-1500 C BT56 fm150css.ies M48 14.0/8.0/7.1/6.1/3.5 1625

FM-1500 D BT56 fm150dss.ies M48 14.0/8.0/7.1/6.1/3.5 1625

FM-1000 A BT56 fmc10ass.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080

MH FM-1000 B BT56 fmc10bss.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080

Coated

FM-1000 C BT56 fmc10css.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080

Lamps FM-1000 D BT56 fmc10dss.ies M47/H36 9.2/5.6/4.7/4.1/2.4 1080

FP-400 B BT37 fp40bss.ies M135/M155 4.0/2.2/1.9/1.8/1.0 456 FP-400 C BT37 fp40css.ies M135/M155 4.0/2.2/1.9/1.8/1.0 456 PS FP-400 D BT37 fp40dss.ies M135/M155 4.0/2.2/1.9/1.8/1.0 456

Clear

FP-1000 B BT37 fp100bss.ies M141 9.0/5.2/4.5/3.9/2.4 1080

Lamps FP-1000 C BT37 fp100css.ies M141 9.0/5.2/4.5/3.9/2.4 1080

FP-1000 D BT37 fp100dss.ies M141 9.0/5.2/4.5/3.9/2.4 1080 FS-400 B ED18 fs40bss.ies S51 4.1/2.5/2.1/1.9/1.1 467 FS-400 C ED18 fs40css.ies S51 4.1/2.5/2.1/1.9/1.1 467

HPS FS-400 D ED18 fs40dss.ies S51 4.1/2.5/2.1/1.9/1.1 467

Clear

FS-1000 B E25 fs100bss.ies S52 9.5/5.5/4.8/4.2/2.5 1100

Lamps FS-1000 C E25 fs100css.ies S52 9.5/5.5/4.8/4.2/2.5 1100

FS-1000 D E25 fs100dss.ies S52 9.5/5.5/4.8/4.2/2.5 1100

EPA Effective Projected Area in Ft 2

23” housing 1.85 26” housing 2.93

Page 4: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Page 4 of 6Type: Job:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HID

G200-116/0614

© 2013 Koninklijke Philips Electronics N.V. All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires

Specifiedforapplications(outsidetheU.S.)where50Hertzoperationisstandard.

HAZ HazardousLocationListed Limited to 400W and 1000W units only.

AvailableonMF(marinelisted)unitsonly.(SeeListingonpage1.)

ClassI,Division2,GroupsA,B,CandD.

50HZ 50HzBallastOperation(consult factory)

TG TeflonBondedtoGlassLens

PB(X) Pre-wiredballast,specifylengthofSOcordin ft:(X = 3,6or10)

EPXY-CTD-WHT WhiteEpoxyCoated EPXY-CTD-GR GrayEpoxyCoated

Class I D iv i s ion 2 , Groups A , B , C , D Measured Max. Internal Measured Max. External Catalog No. Operating Temperature Operating Temperature T Rating

MFM-1000 339°C 163°C T1

MFP-400 316°C 131°C T1 MFP-1000 * 339°C 163°C T1 * Thermal limits require 26” housing for MF Series 1000W PS unit with UL 844 listed HAZ option rating.

MFS-400 374°C 110°C T1 MFS-1000 373°C 123°C T1

Data supplied by Texas Research Institute, Inc., corrected to 23°C. Note: The classification of an area as to class, division and groups and the use of UL 844 listed luminaires in

such areas is solely the judgement of the owner, insurance carrier and the authority having jurisdiction.

5MILTeflon®bondedtostandardglasslens.

Durablecoatingoffersprotectionagainstmildlyacidicoralkalineconditions.

Accessory Details (Field Installed - Shipped Separately)

7.13”(18.09 cm) 3/8”

SetScrew

F-F1-KIT -(F) SingleFuseKit(120V/277V) F-F2-KIT -(F) DoubleFuseKit(208V/240V/480V)

Consistsof1or2fuseholdersand1or2KTK30ampfuses.Fieldinstalledonwiringaccessplate.Fusing not available with MF series (marine listed) units. (F)=specifyfinish

Allowswiringconnectionstobemadeinremotemountedjunctionbox.UsefulwithvariousmountingaccessoriessuchasWB1wallbracket.

Bi-Levelprovideshigh/lowleveloflampoutputwithupto50%powerconsumption.Zerocross-overnetworkavoidsstrobingandlampdropout.

LQ Hot/ColdQuartzRestrike Note: Standard 150 watt (120V) double contact

bayonet base socket.

Combined Quartz wattage may not exceed HID lamp wattage.

LQ40 Hot/ColdQuartzRestrikeforCold WeatherStartsto-40°C(-40°F)

F-F1 SingleFuse(120V/277V) F-F2 DoubleFuse(208V/240V/480V) Note: Fusing not available on MF series (marine listed) units. IforderingQVballast,voltagemustbespecified.

FusesareKTK/KLK30ampunlessotherwisespecified.

BL Bi-Level Note: Suitable for HPS in any aiming position. Consult factory when specifying dimming with Metal Halide.

Option Details (Factory Installed)

LQ-ProvidesLiteMaticoperationforfixtureswith120Vormulti-tapballasts.LiteMatic Operation

Main Lamp Reaches Approximately 40% of Rated Output: Quartzlamp

automaticallyextinguishes(combinedlampcurrentsneverexceedthatof

mainlampat100%output).

Normal Start: MainandQuartzlampsbothenergized.

When Arc Extinguished: Auxiliaryquartzlamp

automaticallyenergizedwhenpowerisrestored.

Main Lamp Reaches 40% of Rated Output: Quartzlampautomatically

extinguishes.

CO CutoffOptics Note: AvailablewithBandDreflectorsonly.

Forapplicationswhereglarecontrolisneeded.Requiresuseofpropercutoffshieldaccessory:SK-40-(F)orSK-100-(F)(shippedseparately).

LB LessBallast(remote mount ballast) Note: Remote mount ballast options and accessories are not

available with 1000W HPS or on MF series (marine listed) units.

Opticunitwithmountingarmsshippedwithoutstandardintegralmastfitterandballastassembly.RequiresmountingaccessoryMF-1,TH-1,HV-1,SMB-400orSMB-1000(shippedseparately).

Castaluminummastfitterfor2-3/8”O.D.pipetenon.ForusewithremotemountedballastonallFSeriesmodels.

(Requires a vertical tenon height of 4-5/8” minimum)

(F)=specifyfinish

MF-1-(F) Mastfitter

Note: Remote mount ballast options and accessories are not available with 1000W HPS or on MF series (marine listed) units.

Page 5: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Page 5 of 6Type: Job:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HID

G200-116/0614

© 2013 Koninklijke Philips Electronics N.V. All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires

5.63”(14.29cm)square

8.50”(21.59cm)

9/16”Dia. Hole(4 PlacesTypical)

2-3/8”Pipe

Tenon(5” useable

length)

3.25" Deep(8.25cm)

WiringInspection

Plate

3/4” NPT(Top, Bottom and Back)

6.88”(17.46cm)

square

Castaluminumwallbracketforverticalsurfacesonly.Designedtopermitmountingoffloodlightsonflatverticalsurfaces.

UseinconjunctionwithWB-5forsurfacemountedwiring.

UsedinconjunctionwithWB1forsurfacemountedwiring.Tappedtop,backandbottomfor3/4”conduitorpipe.

GasketprovidedforsealingsurfacewiringboxtoWB-1(wallmountingbracket).

Castaluminumanglebracketwith2”pipestub.

“L”base.

2-3/8”O.D.Pipe

Tenon

9/16”Dia. Hole

(5 Pl. T yp.)

Front View Top View

6.00”(15.24cm)

1.38”(3.49cm)

1.50”(3.81cm)

4.75”(12.07cm)

4.75”(12.07cm)

5.13”(13.02cm)

4.50”(11.43cm)

1.88”(4.76cm)

4.50”(11.43cm)

Bracketwithstandardtwist-lockreceptacleformodelswithintegralballasts.

Threadsinto1/2”NPTholeinballastbaseormastfitter.

(Photocellnotincluded.)

0.5” (1.27cm) Dia.(3 Places Typical)

1.5”(3.81cm)

2.0”(5.08cm)

8.63”(21.91cm)

7.63”(19.37cm)

Castaluminummountingbracketforinstallingfloodlightsonflathorizontalsurfaces.

Forusewith2-3/8”ODpipetenon (byothers).

Limittenonheightto8.0”(20.32cm).

Castaluminumhangertappedfor1-1/4”NPTconduitorpipe.Equipsfloodlightswithremotemountedballastsforuseonstandardloweringdevices.Mountingarmsprovidedwithfixture.

(Requires a vertical tenon length of 4-5/8” minimum)

7.0” (17.78cm)

4.94”4.94” (12.55cm)

(12.55cm)

TH-1-(F) LoweringAdapter (Tenon Hanger) Note: Remote mount ballast options and accessories

are not available with 1000W HPS or on MF series (marine listed) units.

(F)=specifyfinish

HV-1-(F) TrunionBase Note: Remote mount ballast options and accessories

are not available with 1000W HPS or on MF series (marine listed) units.

(F)=specifyfinish

WB-1-(F) WallBracket

(F)=specifyfinish

WB-5-(F) WiringBoxforWB-1andsurface mountedconduitfeed

(F)=specifyfinish

PX-1-(F) Cross-armBracket

Forinstallingfloodlightson woodenorsteelcross-arms.

(F)=specifyfinish

ShockMountingBracketforuseinapplicationswhereseverevibrationmaybepresent.Securesfloodlightwitharemotemountedballastlessmountingarmsormastfitter.Constructedofhot-dipgalvanizedsteelwithneoprenepadstoabsorbshock.Corrosionresistantassemblyhardwareisfurnished.Note: Not available with 1000W HPS or on MF series (marine listed) units.

Castaluminumtrunionbasebracketcalibratedforhorizontaladjustment.

Forusewithremotemountedballast.

SMB-400 ShockMountingBracket (23” housing)

SMB-1000 ShockMountingBracket (26” housing)

FB-1 FlatBaseMount

PCM-1 PhotocellReceptacle MountingBracket

Page 6: Industrial Floodlight - 50-150 att ID - Villa Lighting · Industrial Floodlight - 50-150 att ID ype: Job: ... Overall Dimensions For Reference ... for Pulse Start Metal Halide, and

Page 6 of 6Type: Job:

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Industrial Floodlight - 250-1500 watt HID

G200-116/0614

© 2013 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice.www.philips.com/luminaires

Philips LightingNorth America Corporation200 Franklin Square Drive Somerset, NJ 08873Phone: 855-486-2216

Imported by: Philips Lighting, a division of Philips Electronics Ltd.281 Hillmount Rd, Markham, ON L6C 2S3Tel. 800-668-9008

1/4”thickimpact-resistantpolymerlensprovidesadditionalprotectionoftheglasslens.

Furnishedwithmountinghardwareandstandoffs.

Coloredauxiliarylens(fullytemperedglass). Requirestheuseoftheauxiliarylensframe.

(color)=Lenscolor.(Consultfactorytospecifycolorofglasslens.)Note:Coloredlensreducesefficiency.

Designedforusewithcoloredlenses.Formedaluminumframeisolatestheauxiliarylensfromheatsourceforlongerlife. Gasketedtominimizeparticulateandmoistureentry.Maybeusedasasnootwheninstalledwithoutalens. Mountinghardwareincluded.(F)=Specifyfinish.

PM-1 WoodPoleMountingKitwithoneU-arm Shippingwt.:6lbs(2.7kg)

PM-2 WoodPoleMountingKitwithtwoU-arms Shippingwt.: 9lbs(4.05kg)

PM-3 WoodPoleMountingKitwiththreeU-arms Shippingwt.: 12lbs(5.4kg)

PM-4 WoodPoleMountingKitwithfourU-arms Shippingwt.: 15lbs(6.8kg)

Formountingluminaireswithmastfittersto6.0”to12.0”O.D.woodpoles.

12.0” (30.48cm)

12.0” (30.48cm)

12.0” (30.48cm)

12.0” (30.48cm)

PM-3

PM-1 PM-2

PM-4

Notes

Energy Indep

ende

nce

Secu

rity Act Compliant Pulse Start M

etal Halide

SK-40-(F) CutoffShieldfor23”housing

SK-100-(F) CutoffShieldfor26”housing

Cutoffshieldprovidespreciseverticalcutoffwithoutdistortionoflateralpattern.

(F)=Specifyfinish.

AL-4-F AuxiliaryPolymerLensfor23”housing

AL-10-F AuxiliaryPolymerLensfor26”housing

Foradditionalnarrowbeamglarecontrol,specifytheauxiliarylensframewiththe8-liteinternallouver.Availablefor26”housingonly.(F)=Specifyfinish.

AL-4-F-L/LENS-(F) AuxiliaryLensFramefor23”housing

AL-10-F-L/LENS-(F) AuxiliaryLensFramefor26”housing

ALF-10-F-L/GLASS-LV8-(F) AuxiliaryLensFramewith 8-liteinternallouver

LENS-ALF-F-4-GLASS-(color) ColoredAuxiliaryLens for23”housing

LENS-ALF-F-10-GLASS-(color) ColoredAuxiliaryLens for26”housing