industrial fans & blowers...ubv-48 18,432 41,200 ubv-54 25,984 45,472 ubv-60 29,445 61,000...
TRANSCRIPT
Industrial Fans & Blowers
UDVL DIRECT DRIVE UPBLAST ROOF VENTILATORSFEATURES & BENEFITS• Low silhouette weatherproof closure for vertical air discharge• Direct drive, low maintenance• Spark resistant, cast aluminum airfoil axial impeller• Factory set adjustable pitch impeller• Aerodynamically efficient performance• TEFC industrial duty motor• Weather-tight steel curb panel• Heavy duty welded steel construction• Baked polyester powder coat finish with a zinc rich primer• Rugged galvanized damper section with butterfly damper blades• Damper rods turn in nylon bearings and require no lubrication
APPLICATIONS• General ventilation • Exhaust or smoke fumes
ACCESSORIES / OPTIONS• Pre-fabricated roof curbs • Disconnect switches, mounted or mounted & wired• Explosion proof & special duty motors • Magnetic damper pads for positive closure• Hot dipped galvanized construction • Baked epoxy powder coat finish, two layers • 304 or 316 stainless steel construction • AMCA spark resistant construction - consult factory
www.continentalfan.com
ROOF VENTILATORS
H = SQ. ROOF OPENING REQ’D.
C
B
A
G - DIM., VARIES WITH TYPE OF MOTORAPPROXIMATE DIMENSION SHOWN IN TABLE
F
ED
G
BUTTERFLY DAMPER
WIND BAND
THROATCURB CAP
MINIMUM CFM VALUE REQUIRED TO OPEN DAMPER BLADES
MODEL A B C D E F G HWT (LBS)LESS MTR
MAX MTR FRAME
UDVL-18 19 24 33 SQ. 2.5 3 16 13 24 150 145TUDVL-24 25 30 39 SQ. 2.5 3 19 15 30 213 184TUDVL-30 31 36 45 SQ. 2.5 3 22 15 36 255 184TUDVL-36 37 42 51 SQ. 2.5 3 25 18 42 305 215TUDVL-42 43 48 57 SQ. 2.5 3 27 18 48 295 256TUDVL-48 49 54 63 SQ. 2.5 3 30 20 54 490 256TUDVL-60 61 66 75 SQ. 2.5 3 42 22 66 615 256T
DIMENSIONS IN INCHES*
MODEL MINIMUM MAXIMUMUDVL-18 2,650 4,600UDVL-24 4,715 10,500UDVL-30 7,365 17,750UDVL-36 10,605 22,600UDVL-42 14,435 28,970UDVL-48 18,765 41,000UDVL-60 29,445 54,000
AIRFLOW PERFORMANCE (CFM)
*DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS
ROOF VENTILATORS
C
B
A
F
E
D
BUTTERFLY DAMPER
WIND BAND
THROAT
CURB CAP
MODEL A B C D E FWT (LBS)LESS MTR
MAX MTRFRAME
UBVL-24 25 30 39 SQ. 2.5 3 19 270 145TUBVL-30 31 36 45 SQ. 2.5 3 22 330 145TUBVL-36 37 42 51 SQ. 2.5 3 25 350 145TUBVL-42 43 48 57 SQ. 2.5 3 27 413 184TUBVL-48 49 54 63 SQ. 2.5 3 30 478 184TUBVL-54 55 60 69 SQ. 2.5 3 36 830 184TUBVL-60 61 66 75 SQ. 2.5 3 42 895 184T
DIMENSIONS IN INCHES*
MODEL MINIMUM MAXIMUMUBVL-24 4,715 7,090UBVL-30 7,365 12,473UBVL-36 10,605 16,554UBVL-42 14,435 23,645UBVL-48 18,765 33,160UBVL-54 23,850 37,458UBVL-60 29,445 44,600
MINIMUM CFM VALUE REQUIRED TOOPEN DAMPER BLADES
AIRFLOW PERFORMANCE (CFM)
UBVL BELT DRIVE UPBLAST ROOF VENTILATORSFEATURES & BENEFITS• Low silhouette weatherproof closure for vertical air discharge• V-belt drive for low speed operation• Spark resistant, cast aluminum airfoil axial impeller• Factory set adjustable pitch impeller• Aerodynamically efficient performance• TEFC industrial duty motor• Self-aligning pillow block ball bearings• Weather-tight steel curb panel• Heavy duty welded steel construction• Baked polyester powder coat finish with a zinc rich primer• Rugged galvanized damper section with butterfly damper blades• Damper rods turn in nylon bearings and require no lubrication
APPLICATIONS• General ventilation • Exhaust or smoke fumes
ACCESSORIES / OPTIONS• Pre-fabricated roof curbs • Disconnect switches, mounted or mounted & wired• Explosion proof & special duty motors • Magnetic damper pads for positive closure• Hot dipped galvanized construction • Baked epoxy powder coat finish, two layers • 304 or 316 stainless steel construction • AMCA spark resistant construction - consult factory
*DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS
www.continentalfan.com
ROOF VENTILATORS
C
A
B
F
MOTOR COVER
D
WIND BAND
FAN SECTION
CURB CAP
VARIESW/ FAN
BUTTERFLY DAMPER
UBV BELT DRIVE UPBLAST ROOF VENTILATORSFEATURES & BENEFITS• Standard upblast weatherproof closure for vertical air discharge• V-belt drive for low speed operation• Spark resistant, cast aluminum airfoil axial impeller• Factory set adjustable pitch impeller• TEFC motor located outside of airstream• Adjustable motor base with self-aligning pillow block ball bearings• Completely sealed belt tube to protect V-belt drive• Extended lube lines• Heavy duty welded steel construction• Weather-tight steel curb panel • Baked polyester powder coat finish with a zinc rich primer• Rugged galvanized damper section with butterfly damper blades• Damper rods turn in nylon bearings and require no lubrication
APPLICATIONS• General ventilation • Exhaust, heat or smoke fumes• Moisture laden air • Mild contaminates in the air steam
ACCESSORIES / OPTIONS• Pre-fabricated roof curbs • Disconnect switches, mounted or mounted & wired• Explosion proof & special duty motors • Magnetic damper pads for positive closure• Hot dipped galvanized construction • Baked epoxy powder coat finish, two layers • 304 or 316 stainless steel construction • AMCA spark resistant construction - consult factory
MODEL A B C D FWT (LBS)LESS MTR
MAX MTR FRAME
UBV-18 18 24 33 SQ. 2.5 12.0 240 145TUBV-24 24 30 39 SQ. 2.5 16.0 333 182TUBV-30 30 36 45 SQ. 2.5 18.0 430 184TUBV-36 36 42 51 SQ. 2.5 22.5 455 213TUBV-42 42 48 57 SQ. 2.5 25.0 650 215TUBV-48 48 54 63 SQ. 2.5 25.5 680 215TUBV-54 54 60 69 SQ. 2.5 28.5 810 215TUBV-60 60 66 75 SQ. 2.5 32.0 850 254T
MODEL MINIMUM MAXIMUM UBV-18 2,650 5,350UBV-24 4,715 10,500UBV-30 7,365 16,440UBV-36 10,605 22,500UBV-42 14,435 33,300UBV-48 18,432 41,200UBV-54 25,984 45,472UBV-60 29,445 61,000
AIRFLOW PERFORMANCE (CFM)DIMENSIONS IN INCHES*
*DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS MINIMUM CFM VALUE REQUIRED TO OPEN DAMPER BLADES
ROOF VENTILATORS
D
SQ. INSIDE BASE
E
B
A
FAN PANEL DIMENSION
G DAMPER (OPTIONAL)
CURB
2-1/2”
HRV HOODED ROOF VENTILATORSFEATURES & BENEFITS• Supply or exhaust applications• Direct drive (HRVD) or belt drive (HRVB) arrangements• Spark resistant, cast aluminum airfoil axial impeller• Factory set adjustable pitch impeller• Aerodynamically efficient performance• Heavy duty welded steel base• Baked polyester powder coat finish with a zinc rich primer• Hinged aluminum hood with galvanized birdscreen• TEFC industrial duty motor• Direct drive units are easily maintained – no belts or pulleys• Belt drive units have self-aligning pillow block bearings• Belt drive units use v-belt drive for low speed operation
APPLICATIONS• General ventilation • Fume and smoke exhaust• Make-up air • Filtered air supply• Heat exhaust
ACCESSORIES / OPTIONS• Filtered intake unit • 2” thick disposable filters, for filtered intake unit• Gravity shutter for exhaust only • Variable pitch sheaves for easy & accurate adjustment• Pre-fabricated roof curbs • Disconnect switch - mounted, or mounted & wired• Custom curb panel to match existing curb • Motor operated damper for supply or exhaust applications• Explosion proof motors • Baked epoxy powder coat finish, two layers• Special duty motors • AMCA spark resistant construction - consult factory
MODEL A B D E GWT (LBS)LESS MTR
MAX MTR FRAME HP
HRV-24 30 54 x 64 41.5 39 25.5 324 145T 1/4 - 1HRV-30 36 60 x 76 41.5 45 25.5 365 145T 1/3 - 11/2HRV-36 42 72 x 82 45.5 51 27.5 410 145T 1/3 - 2HRV-42 48 80 x 89 45.5 57 27.5 503 184T 1/2 - 3HRV-48 54 87 x 95 49.5 63 29.5 630 184T 3/4 - 5HRV-54 60 92 x 98 50.5 69 29.5 870 215T 1 - 5HRV-60 66 90 x 107 54.5 75 31.5 1140 215T 1 - 10
DIMENSIONS IN INCHES*
MODEL MINIMUM MAXIMUMMAXIMUM CFMW/ FILTERS
HRV-24 800 6,700 4,875HRV-30 800 11,800 12,000HRV-36 1,800 15,376 14,000HRV-42 3,300 22,296 16,000HRV-48 4,283 30,900 18,000HRV-54 8,000 35,238 17,500HRV-60 9,600 47,000 32,000
AIRFLOW PERFORMANCE (CFM)
*DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS
Industrial Fans& Blowers
Commercial Fans& Dampers
OEM Solutions& Custom Fans
Residential Fans & Air Puri�ers