index: fittings, flanged pipes and valves made of …...fittings, flanged pipes and valves made of...

140
Index: (click with mouse) Düker in general Preamble The complete product range –> Index Location plan Flag / Addresses FITTINGS AND VALVES We designed the electronic version of our product catalogue user-friendly. In addition to useful information you will find the complete product range of Düker “fittings and valves”. To see each detailed information, please click on the desired category within the index. To get back to the Index please click on the blue area (chapter) at the top margin. Fittings, Flanged pipes and Valves made of Ductile Cast Iron ( GGG ) http://www.dueker.de

Upload: others

Post on 19-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Fittings, flanged pipes and valves made of

ductile cast iron (GGG)

Index: (click with mouse)

Düker in general

Preamble

The complete product range –> Index

Location plan

Flag / Addresses

FITTINGS AND VALVES

We designed the electronic version of our product catalogue user-friendly.

In addition to useful information you will find the complete product range of Düker “fittings and valves”.

To see each detailed information, please click on the desired category within the index.

To get back to the Index please click on the blue area (chapter) at the top margin.

Fittings, Flanged pipes andValves made of Ductile Cast Iron ( GGG )

http://www.dueker.de

Page 2: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

© 05.2015 E

Hauptstraße 39–41, 63846 Laufach, Germany

All rights reserved, including copying as a whole or in part.

Deviations in dimensions and weights and in the illustrations are possible. In the interest of technical progress, we reserve the right to implement changes and improvements to the products without previous announcement.

Düker GmbH & Co. KGaAHauptstraße 39 – 41, 63846 Laufach, GermanyPhone: + 49 6093 87-560 Telefax: + 49 6093 87-246e-mail: [email protected] Internet: http://www.dueker.de

Member ofFGR / EADIPS association

Back to summary

Page 3: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Düker GmbH & Co. KGaA76

As early as in 1469, official documents mentioned a mine, which developed more or less continually into today’s company Düker.The foundry and enamelling works cover a production area of more than 80,000 square meters with approx. 650 employees.

At Laufach / Spessart and Karlstadt / Main, Düker manufactures products used in:

Drainage technology• Hubless drainage pipe systems• couplings for hubless drainage pipe systems Underground construction• flanged pressure pipes• fittings and• valves Chemical industry Acid-proof glass-lined … • pipes• valves • special valves and• columns Jobbing foundry• castings in small, medium and large series• various cast iron qualities (grey cast iron and spheroidal cast iron), raw and machined• various casting procedures (hand moulding, machine casting, centrifugal casting)

Back to summary

Page 4: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

98

How to find Düker …Back to summary

Page 5: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

1110

1

2

3

4

5

6

Joints for fittings, flanged pipes and valves made of ductile cast iron (GGG)

Ductile cast iron (GGG) fittings and flanged pressure pipes

Ductile cast iron (GGG) valves

Accessories

Laying and assembly instructions

Contacts

Back to summaryWe keep on moving …

Dear customer, dear business friends,We are glad to present you the new edition of our product catalogue for fittings, flanged pipes and valves made of ductile cast iron for underground construction.In addition to quality and reliability as well as to the extension and specifying of our product range we always assist you with planning, service and individual customer care.You can always depend on Düker consultants, technicians and designing engineers regarding questions, particular tasks and demands. Of course we also appreciate your incitations and criticism.Demand us – give us a call !

Your Sales Department

Phone: +49 6093 87-560

Page 6: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Description Code Page

1 Joints for fittings, flanged pipes and valves made of ductile cast iron (GGG) 21

1.1 Socket joints TYTON® socket joints TYT 22 Screw-gland socket joints SMU 23 Bolted-gland socket joints STB 24

1.2 Restrained socket joints TYTON® socket joints with TYTON® SIT® 26 with TYTON SIT PLUS® ( TSP® ) 27

Novo socket joints with NOVO-SIT® 28 with NOVO-Grip® III 29

Screw-gland socket joints with Düker SMU thrust resisting joint 30 with Düker SPEZIAL 31

1.3 Flanged joints PN 10 32 – 33 PN 16 34 – 35 PN 25 36 – 37 PN 40 38 – 39 Hexagon head screws for flanges 40 – 41 Flat gaskets for flanges 42 Arrangement of screw holes 43

Index1312

To page down within the categories please use the navigation bar of the acrobat-reader as well.

Page 7: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

IndexIndex

Description Code Page

Single socket tees with spigot and socket branch B 84 Double flanged bends 90° Q 85 Double flanged duckfoot bends 90° N 86 Double flanged bends 45° FFK 45 87 Double flanged bends 30° FFK 30 88 Double flanged bends 22 1/2° FFK 22 89 Double flanged bends 11 1/4° FFK 11 90 All flanged tees T 91 – 96 Flanged tees with 45° flanged branch FFC 97 – 99 All flanged cross tees TT 100 – 102 Double flanged tapers concentric FFR 103 – 105 Double flanged tapers eccentric FFRe 106 – 108 Single flange bells 109 Blank flanges X 110 – 111 Blank flanges with tap hole XG 112 – 113 Pipe caps with TYTON® socket O 114 – 115 Conversion flanges 116 Flanged socket duckfoot bends 90° EN 117 Flanged socket duckfoot bends 90° with Novo sockets MMN / MMNR 118 Plugs for screw-gland and TYTON® sockets P 119 Screw rings for plugs 120 Screwed plugs for screw-gland socket PX 121 Double socket and double flanged hatchboxes: see sewage fittings programme

2.3 Special fittings 123 Single socket tees with 45° socket branch

with screw-gland sockets C Socket-spigot tapers with screw-gland socket R Flanged socket bends 90° with screw-gland socket EQ Fittings with Puddle Flanges 124 – 125

1514Description Code Page

2 Ductile cast iron (GGG) fittings and flanged pressure pipes 45 Inside and outside protection 47

2.1 Flanged pressure pipes Pressure pipes with cast-on flanges FFG 48 Weight table FFG 49

2.2 Fittings Notes 50 Marking 51

Flanged sockets E 52 – 53 Flanged sockets EU 54 – 55 Flanged spigots F 56 Collars U 57 Single socket bends 90° MQ 58 Double socket bends 90° MMQ 59 Single socket bends 45° MK 45 60 Double socket bends 45° MMK 45 61 Single socket bends 30° MK 30 62 Double socket bends 30° MMK 30 63 Single socket bends 22 1/2° MK 22 64 Double socket bends 22 1/2° MMK 22 65 Single socket bends 11 1/4° MK 11 66 Double socket bends 11 1/4° MMK 11 67 Double socket tees with flanged branch MMA 68 – 73 All socket tees MMB 74 – 78 Double socket tees with 45° socket branch – MMC see sewage fittings programme Double socket tapers MMR 79 – 81 Single socket tees with spigot and flanged branch A 82 – 83

Page 8: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

IndexIndex

Description Code Page

2.4 Fittings for plastic pipelines (KS fittings) Notes 127

Flanged sockets E-KS 128 Flanged spigots F-KS 129 Flanged socket duckfoot bends 90° EN-KS 130 Double socket tees with flanged branch MMA-KS 131 – 132 All socket tees MMB-KS 133 Double socket tapers MMR-KS 134 Double sockets with internal thread branch MMI-KS 135 – 136

2.5 Sewage fittings Notes 137

Drilling saddle pieces with 90° branch with clay pipe socket SM 90 138 with 45° branch with clay pipe socket SM 45 139 with 90° branch with spigot for ductile iron pipe or for clay pipe SI 90 140 with 45° branch with spigot for ductile

iron pipe SI 45 141 TYTON® coupling MM 142 Spigot end branches 67° ICI 67 143 Double socket branch with TYTON® sockets, with 67°/45° branch with spigot for ductile iron pipe MMI 144 Double socket branch with TYTON® sockets, with 45° branch with clay pipe socket MMM 145 Pipe sealing cap with ventilation valve RVD 146 Manhole connection pieces with TYTON® socket SA 147 Double flanged hatchboxes 148 Double socket hatchboxes 149 Double socket tees with 45° socket branch MMC 150 – 151

Description Code Page

3 Ductile cast iron (GGG) valves

3.1 Gate valves Type 4004 with flanges 154 – 155 Type 2004 with flanges (short face-to-face length) 156 – 157 Type 4004 with Novo sockets 158 – 159 Type 4004 with Novo socket and spigot 160 – 161 Type 4004 with screw-gland sockets 162 – 163 Type 2004 with flange and screw-gland socket 164 – 165 (short face-to-face length) Type 4004 with PE welding studs 166 – 167 Type 4004 replacement and repair valve 168 – 169 with rotatable flanges Type 2004 replacement and repair valve 170 – 171 with rotatable flanges (short face-to-face length) Type 3004 with welding studs for steel pipes 172 – 173 Type 4004 with blow-off pipes and PE welding studs 174 – 175 Type 3004 with blow-off pipes and welding studs for steel pipes 176 – 177 Type 3004 with blow-off pipes and PE welding studs 178 – 179

3.2 Service connection valves Tapping valve TOP (top drilling) 180 – 181 Tapping valve TOPsi (horizontal drilling) 182 – 183 Tapping valve TOP with PE connection 184 – 185 Tapping clamps 186 Clapping bands 187 Type 1004 with internal thread 188 – 189 Type 1004 with PE welding studs 190 – 191 Type 1004 with flange and PE welding stud 192 – 193 Type 1004 with internal thread and PE welding stud 194 – 195 Gate valve combination Multi I 196 – 197

1716

Page 9: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

IndexIndex

Description Code Page

3.6 Various Flap valves 226 – 227

4 Accessories 229 Laying tool for TYTON® or Novo sockets 231 Hook wrench for screw-gland joints 232 Operating keys for valves 233

5 Laying and assembly instructions 235

5.1 Laying instructions for thrust resisting joints Notes on DVGW standard GW 368 237 NOVO-SIT® 238 – 241 TYTON® SIT® 242 – 245 TYTON SIT PLUS® ( TSP® ) 246 – 251 Düker SMU 252 – 255 Düker SPEZIAL 256 – 259 NOVO-Grip® III 260 – 263

5.2 Assembly instructions for socket connections 264 Bolted-gland socket connection 264 – 267

5.3 Assembly instructions for flanges 268 Assembly instructions for pressure pipes

and fittings with flanges 268 – 270

5.4 Assembly instructions for spot-drilling saddle pieces 271 Assembly instructions for spot-drilling saddle pieces 271 – 274

6 Contacts 275 – 277

1918Description Code Page

3.3 Hydrants Underground hydrants Type 304 design A 198 – 199 Type 305 design AD 200 – 201 Type 304 S design A 202 – 203 Pillar fire hydrants Type 494 design AUD 204 – 205 Type 495 design AFUD 206 – 207

3.4 Butterfly valves Typ 451 / 4510 with flanges 208 – 211 Typ 451 / 4510 long face-to-face length with bypass 212 – 215 Typ 4510 with Novo sockets 216 – 217

3.5 Novo plug-in system Notes on Novo plug-in system 219 Gate valve type 4004 with Novo sockets 158 – 159 Gate valve type 4004 with Novo socket and spigot 160 – 161 Butterfly valve type 4510 with Novo sockets 216 – 217 Underground hydrant type 304 S Form A 202 – 203 Pipe section with Novo socket M 220 Flanged socket duckfoot bends 90° with Novo sockets MMN / MMNR 118 Single socket tees with spigot and socket branch B 84 Novo collar U 221 Spigot tee with Novo socket MI 222 – 223 All spigot tee IT 222 – 223 Spigot pipe section S 224 PE adapter piece for Novo sockets 225

Page 10: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

11

Joints for fittings, flanged pipes and valves made of ductile cast iron (GGG)

20

Back to summary

Page 11: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

22 23

11.1

TYTON® socket joints ( TYT ) acc. to DIN 28 603

Screw-gland socket joints ( SMU ) PN 16 1) acc. to DIN 28 601

DN

40 50 65 80100125150200250300350400

450* 500*

ø d1

56 66 82 98118144170222274326378429480532

ø D

101113129146166197224280336391450503572626

t

74 77 80 84 88 91 94100106110113116164174

Pipes

— ——

3,4 4,3 5,7 7,110,314,218,623,729,3——

Fittings

1,4 1,8 2,2 2,8 3,3 4,5 5,6 8,011,114,318,622,2——

Flanged sockets

1,3 1,6 1,9 2,4 3,1 4,0 4,9 7,1 9,712,516,219,5

28,5

Dimensions in mm Weight in kg ≈ socketScrew ring

0,84 0,90 1,30 1,40 1,90 3,00 3,20 4,50 6,30 8,1010,5013,5025,0031,50

Gliding ring

0,050,060,060,070,080,100,110,170,210,300,350,400,600,87

Gasket

0,060,080,100,120,150,190,230,360,500,660,841,051,501,85

Dimensions and weights

* acc. to manufacturer’s standard 1) higher pressures on request

Socket for flanged sockets and collars Socket for pipes

Socket for fittings

DN

80 100 125 150 200 250 300 350 400

450* 500 600 700 800 900100012001400

ø d1

98 118 144 170 222 274 326 378 429 480 532 635 738 842 945104812551462

ø D

141 161 188 215 271 324 381 434 489

541,5 598 707 825 9351042115013681610

t

84 88 91 94100105110110110120120120150160175185215240

Pipes

3,4 4,3 5,7 7,1 10,3 14,2 18,6 23,7 29,3 37,8 42,8 59,3 79,1102,6129,9161,3

——

Fittings

2,8 3,3 4,5 5,6 8,0 11,1 14,3 17,1 20,8 27,6 31,7 42,3 71,2 95,4150,3186,9250,0468,7

Flanged sockets

2,43,14,04,97,19,7

12,515,218,624,327,636,259,179,8

122,7152,1193,0373,0

Gasket

0,130,160,190,220,370,480,670,771,091,401,602,294,005,206,508,009,50

17,20

Dimensions in mm Weight in kg ≈ socket

Dimensions and weights

Socket for flanged sockets and collars Socket for pipes

Socket for fittings

* acc. to manufacturer’s standard

Page 12: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

2524

11.11.1

Bolted-gland socket joints ( STB ) PN 16 1) acc. to DIN 28 602

Assembly instructions see page 264 – 267

DN

100*150*200*250*300*350*400*450*500600700800900

1000120014001600

ø d1

118170222274326378429480532635738842945

1048125514621668

ø D

235 290 345 400 460 515 570 625 680 790 900101011251250145017141920

t

116118121124127129132135138143149154160165176187198

ø d2

M 20M 20M 20M 20M 20M 20M 20M 20M 20M 20M 20M 20M 20M 24M 24M 24M 24

l

80 80 80 80 90 90 90100100100110110120120130150150

n

4 8 8 8 8 12 1212 16 16 20 242424283236

Pipes

— ————26,632,245,345,361,280,0

101,0128,0162,9232,4

Flanged sockets collars

————18,722,927,638,738,752,267,985,4

108,4138,7196,5292,3319,5

Dimensions in mm Weight in kg ≈ socketBolted- gland ring

2,74,0 5,06,07,19,6

10,613,015,020,927,234,144,057,075,0

128,5142,8

Gasket

0,100,200,270,500,600,700,801,001,001,501,902,302,803,303,806,907,90

Hammer head

screws

0,24 0,24 0,24 0,24 0,27 5,5 5,5 6,0 7,7 7,7 10,0 12,0 12,0 13,0 18,0 19,5 22,0

Dimensions and weights

* acc. to manufacturer’s standard 1) higher pressures on request

Socket for pipes and fittings Socket for flanged sockets

Page 13: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

2726

11.2

TYTON® socket joints with TYTON® SIT®

DN

80100125150200250300400

Number of retaining segments

4 5 5 710152030

allowable operating pressure

PFA

1616161616101010

Deflection max.

3 °3 °3 °3 °3 °3 °3 °3 °

Weight in kg ≈ TYTON® SIT®-

gasket

0,170,190,230,270,450,600,921,58

Dimensions and weights

Assembling acc. laying instruction for thrust resisting joint TYTON® SIT®, page 242 – 245

Pressure classes as per EN 545 : 2011-09

Definitions as per EN 805Allowable operating pressure PFA (bar)Allowable maximum operating pressure: PMA (bar) = 1.2 x PFAAllowable site test pressure: PEA (bar) = 1.2 x PFA + 5

Pressure class

C 100C 100C 64C 64C 64C 50C 50C 40

TYTON® socket joints with TYTON SIT PLUS®

Assembling acc. laying instruction for thrust resisting joint TYTON SIT PLUS®, page 246 – 251

DN

80 100 125 150 200 250 300 350 400 500 600

Number of retaining segments

4 5 5 710152025283542

Pressure class

C 100C 100C 100C 100 C 64 C 64 C 50 C 50 C 50 C 40 C 40

Pressure class

C 50 C 50 C 50 C 50 C 50 C 50 C 40

allowable operating pressure

PFA

16161616161616

allowable operating pressure

PFA

3232252525252525161610

Deflection max.

3 °3 °3 °3 °3 °3 °3 °3 ° 2 ° 2 ° 2 °

Weight in kg ≈ TYTON SIT PLUS®

gasket

0,140,160,200,230,450,600,951,251,502,303,00

Dimensions and weights

Page 14: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

28 29

11.2

Novo socket joints with NOVO-SIT®

Assembling acc. laying instruction for thrust resisting joint NOVO-SIT®, page 238 – 241

DN

80 100 125 150 200 250 300 350 400 450 500 600 700 800

d1

98 118 140 170 222 274 326 378 429 480 532 635 738 842

D

141 161 188 215 271 324 381 434 505 572 598 707 824 934

t

119123126129138143152154154164168168205217

Pressure class

C 100C 100C 100C 100 C 64 C 64 C 50 C 50 C 50 C 40 C 40 C 40 C 40 C 40

Pressure class

C 50 C 50 C 50 C 50 C 50 C 50 C 50

allow. o. p.PFA

25161616161616

allow. o. p.PFA

4025252525252516161616161010

Deflectionmax.

3 °3 °3 °3 °3 °3 °3 °3 °3 °3 °2 °2 °2 °1 °

NovoPre-

chamber

1,2 1,4 1,8 2,1 3,1 4,8 5,7 6,4 8,3 9,512,016,629,536,6

NOVO-SIT®

ring

0,150,200,250,350,650,801,001,301,502,002,503,003,503,60

Dimensions in mm Weight in kg ≈

Dimensions and weights

Number of

locking segments

5571013182222252835456270 Assembling acc. laying instruction for thrust resisting joint NOVO-Grip® III, page 260 – 263

* Note: in DN 200, it is not possible to use the standard Novo socket for NOVO-Grip®; use only items with adapted geometry and marking „for PE-HD pipes“.

Restrained socket joints for plastic pipelines with NOVO-Grip® III

Locking ringCompression ring

Gasket (GKS)

DN

80100125150200*

ø d1

plastic pipelines DN/OD in mm

90110140160225

t

119123126129138

Weight in kg ≈ assembly set

0,200,250,300,501,00

PFA at SDR 11 bar

1616161616

PFA at SDR 17 bar

1010101010

Dimensions and weights

Note: The Novo socket does not change the standardised length of fittings and valves.

Page 15: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

313030

11.2

Screw-gland socket jointswith DÜKER thrust resisting joint SMU DN 40 – DN 65

Assembling acc. laying instruction for thrust resisting joint SMU, page 252 – 255

DN

40 5065

allowable operating pressurePFA

161616

Deflectionmax.

3 °3 °3 °

Pressureclass

C 50C 50C 50

Weight in kg ≈ locking ring

0,0750,1000,140

Dimensions and weights

Screw-gland socket joints with thrust resisting joint Düker SPEZIALDN 80 – DN 400

Assembling acc. laying instruction for thrust resisting joint Düker SPEZIAL, page 256 – 259

DN 80 – 250 Locking ringDN 300 – 400 Segment ring

DN

80100125150200250300400

allowable operating pressure

PFA

1616161616161616

Pressure class

C 50C 50C 50C 50C 50C 40C 40C 40

Deflectionmax.

3 °3 °3 °3 °3 °2 °2 °2 °

Locking ring

0,220,260,310,370,520,67——

Weight in kg ≈ SPEZIAL screw ring and

Dimensions and weights

Segment ring

——————

10,3516,00

Page 16: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

3332

11.3

Flanged joints PN 10 acc. to EN 1092-2

Flanged joints PN 10 acc. to EN 1092-2

* n = number of bolt holes

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

Pipe ø d1

56 66 82 98 118 144 170 222 274 326 378 429 480 532 635 738 842 9451048125514621668

ø D

150 165 185 200 220 250 285 340 400 455 505 565 615 670 780 895101511151230145516751915

C

19,019,019,019,019,019,019,020,022,024,524,524,525,526,530,032,535,037,540,045,046,049,0

ø K

110 125 145 160 180 210 240 295 350 400 460 515 565 620 725 840 95010501160138015901820

n*

4 4 4 8 8 8 8 81212161620202024242828323640

ø L

19191919191923232323232828283131343437414450

ø N

70 84 104 120 140 170 190 246 298 348 408 456 502 559 658 772 876 9761080129214961712

Dimensions in mm h

39,0 40,0 41,5 43,0 45,0 47,5 50,0 55,0 60,0 65,0 70,0 75,0 80,0 85,0 95,0105,0115,0125,0135,0155,0175,0195,0

ø d

84 99 118 132 156 184 211 266 319 370 429 480 530 582 682 794 901 10011112 132815301750

f

3333333334444455555555

Weight in kg

1,7 2,1 2,6 2,8 3,3 4,0 5,0 6,9 9,8 13,0 14,7 17,2 20,0 23,2 32,8 44,3 58,8 69,6 87,6121,0180,0262,0

Flange Neck Raised face

Dimensions and weights PN 10

Page 17: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

3534

11.3

Flanged joints PN 16acc. to EN 1092-2

Flanged joints PN 16acc. to EN 1092-2

* n = number of bolt holes

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

Pipe ø d1

56 66 82 98 118 144 170 222 274 326 378 429 480 532 635 738 842 9451048125514621668

ø D

150 165 185 200 220 250 285 340 400 455 520 580 640 715 840 910102511251255148516851930

C

19,0 19,0 19,0 19,0 19,0 19,019,020,022,0 24,5 26,528,030,031,536,039,543,046,550,057,060,065,0

ø K

110 125 145 160 180 210 240 295 355 410 470 525 585 650 770 840 95010501170139015901820

n*

4 4 4 8 8 8 8121212161620202024242828323640

ø L

19191919191923232828283131343737414144505057

ø N

70 84 104 120 140 170 190 246 296 350 410 458 516 576 690 760 862 9621076128214821696

Dimensions in mm h

39,0 40,0 41,5 43,0 45,0 47,5 50,0 55,0 60,0 65,0 70,0 75,0 80,0 85,0 95,0 105,0 115,0 125,0 135,0 155,0175,0195,0

ø d

84 99 118 132 156 184 211 266 319 370 429 480 548 609 720 794 90110011112132815301750

f

3333333334444455555555

Weight in kg

1,7 2,1 2,6 2,8 3,3 4,0 5,0 6,7 9,4 12,6 17,5 22,1 30,2 37,4 57,6 57,4 76,8 91,4127,0185,0213,0315,0

Flange Neck Raised face

Dimensions and weights PN 16

Page 18: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

36 37

11.3

Flanged joints PN 25acc. to EN 1092-2

Flanged joints PN 25acc. to EN 1092-2

* n = number of bolt holes

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

Pipe ø d1

56 66 82 98 118 144 170 222 274 326 378 429 480 532 635 738 842 9451048125514621668

ø D

150 165 185 200 235 270 300 360 425 485 555 620 670 730 845 960108511851320153017551975

C

19,019,019,019,019,019,020,022,024,527,530,032,034,536,542,046,551,055,560,069,074,081,0

ø K

110 125 145 160 190 220 250 310 370 430 490 550 600 660 770 875 99010901210142016401860

n*

4 4 8 8 8 8 8121216161620202024242828323640

ø L

19191919 23 28 28 28 31 31 34 37 37 37 41 44 50 50 57 576262

ø N

70 84 104 120 142 162 192 252 304 364 418 472 520 580 684 780 882 9821086129615081726

Dimensions in mm h

39 4041,5 43 4547,5 50 55 60 65 70 75 80 85 95105115125135155175195

ø d

84 99 118 132 156 184 211 274 330 389 448 503 548 609 720 820 92810281140135015601780

f

3333333334444455555555

Weight in kg

1,7 2,1 2,4 2,8 3,8 4,7 6,0 8,7 13,0 17,7 25,4 33,2 40,2 47,2 71,5 90,0123,0149,0201,0 285,0357,0484,0

Flange Neck Raised face

Dimensions and weights PN 25

Page 19: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

3938

11.3

Flanged joints PN 40acc. to EN 1092-2

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600

Pipe ø d1

56 66 82 98 118 144 170 222 274 326 378 429 480 532 635

ø D

150165185200235270300375450515580660685755890

C

19,019,019,019,019,023,526,030,034,539,544,048,049,052,058,0

ø K

110125145160190220250320385450510585610670795

n*

4 4 8 8 8 8 81212161616202020

ø L

191919192328283134343741414450

ø N

70 84104120142162192254312378432498522576686

Dimensions in mm h

39,0 40,0 41,5 43,0 45,0 47,5 50,0 55,0 60,0 65,0 70,0 75,0 80,0 85,0 95,0

ø d

84 99 118 132 156 184 211 284 345 409 465 535 560 615 735

f

333333333444445

Weight in kg

1,7 2,1 2,4 2,8 3,8 5,9 8,0 14,0 23,5 33,5 43,0 62,0 57,0 82,0124,0

Flange Neck Raised face

Dimensions and weights PN 40

Flanged joints PN 40acc. to EN 1092-2

* n = number of bolt holes

Page 20: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

4140

11.3

Hexagon head screws for flanges PN 25 and PN 40 acc. to EN 1092-2

Hexagon head screws for flanges PN 10 and PN 16 acc. to EN 1092-2

l1* = Screw length for connection with one washer l2** = Screw length for connection with two washersSpecial stipulations: M16 x 80: Thread length min. 44 mm, M20 x 90: Thread length min. 52 mm, M24 x 100/110: Thread length min. 60 mm; l1* = Screw length for connection with one washer l2** = Screw length for connection with two washers

qty per joint

4 4 8 8 8 8 81212161616202020

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 90010001200

ø d1

M 16M 16M 16M 16M 20M 24M 24M 24M 27M 27M 30M 33M 33M 33M 36M 39M 45M 45M 52M 52

l1*

80 80 80 80 80 90 90 90 100 110120 130 130 140150170180190210230

l2**

80 80 80 80 90 90 90

100 110 110120 130 130 140150170190200210230

qty per joint

4 4 8 8 8 8 812121616162020202424282832

Dimensions in mm Dimensions in mm

ø d1

M 16M 16M 16M 16M 20M 24M 24M 27M 30M 30M 33M 36M 36M 39M 45

l1*

80 80 80 80 80

100100110120140 150160160170190

l2**

80 80 80 80 90

100110120130140 150170170180200

PN 40PN 25

Not specified in EN 1092-2

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

ø d1

M 16M 16M 16M 16M 16M 16M 20M 20M 20M 20M 20M 24M 24M 24M 27M 27M 30M 30M 33M 36M 39M 45

l1*

80 80 80 80 80 80 80 80 90 90 90

100 100 100 110 120130130

140160170180

l2**

80 80 80 80 80 80 90 90 90 90 90

100 110 110 120 120130140 150160170190

qty per joint

4 4 4 8 8 8 8 81212161620202024242828323640

Dimensions in mm Dimensions in mm

ø d1

M 16M 16M 16M 16M 16M 16M 20M 20M 24M 24M 24M 27M 27M 30M 33M 33M 36M 36M 39M 45M 45M 52

l1*

80 80 80 80 80 80 80 80 90

100 100 110 110120 130 140150160170190200220

l2**

80 80 80 80 80 80 90 90

100 100 110 110 120120 140 150160160180200210230

qty per joint

4 4 4 8 8 8 8121212161620202024242828323640

PN 16PN 10

Page 21: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

4342

11.3

Arrangement of bolt holesFlat gaskets for Flanges acc. to EN 1514-1, type IBC

Dimensions for gaskets with steel inlay.The number of bolt holes is always divisible by 4.The bolt holes are arranged symmetrically to the two main axes, but not on them.

DN

40 50 65 80 100 125 150 200 250 300 350 400 500 600 700 800 9001000120014001600

ø D 1

49 61 77 90 115 141 169 220 274 325 368 420 520 620 720 820 9201020122014201620

PN 10

328 378 438 490 595 695 810 91510151120

15451770

ø D 2

92 107 127 142 162 192 218 273

1340

PN 16

330 385 445 497 618 735 805 91010051110

15401760

s

444455566677778888888

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

EN 1092-2PN 10

4 4 4 8 8 8 8 81212161620202024242828323640

EN 1092-2PN 16

4 4 4 8 8 8 8121212161620202024242828323640

EN 1092-2PN 25

4 4 8 8 8 8 812121616162020202424282832——

EN 1092-2PN 40

4 4 8 8 8 8 81212161616202020———————

Dimensions and weights

Number of bolts

Page 22: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

44

22

Ductile cast iron ( GGG ) fittings and flanged pressure pipes

Back to summary

Page 23: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

4746

2

Flanged pipes and fittings can be supplied with the following coatings and linings:

1. Cement mortar lining The cement mortar lining is acc. to DVGW data sheet W 347 and W 270 resp. EN 545

or EN 598 • avoids corrosion

• prevents deposits and supports stable hydraulic characteristics.

2. Enamelling (glass lining) – lining and coating Enamel is an effective protection against corrosion, abrasion and incrustation. A non detachable,

chemical bounding to the cast iron avoids corrosion by undercutting. The layer thickness after application ( temperature ≈ 800 ° ) is between 200 µ and 500 µ.

3. Epoxy resin – lining and coating The coating is acc. to RAL-GZ 662 with hot melted epoxy powder. The requirements of EN 14901

(pressure pipes and fittings) as well as of DIN 30677 T.2 (heavy corrosion protection for valves) are fulfilled.

4. Special coatings (outside ) Various coatings on request.

Inside and outside protection

Page 24: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

4948

22.1

Pressure pipes with cast-on flanges FFG-pipes

Further lengths are available on request.

Weight of pressure pipes with cast-on flanges PN 10 FFG-pipes

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

L max.

1000100010002000200020002000200030003000300030003000300030002000200020002000200020002000

1 m pipe

without flange

6,9 10,7 11,0 16,1 20,4 26,4 32,4 46,1 61,3 78,1 96,5116,2132,8160,6211,3268,5332,1401,7477,7565,2740,0932,0

PN 10

1,7 2,1 2,6 2,8 3,3 4,0 5,0 6,9 9,813,014,717,2—

23,232,844,358,569,687,6

121,0——

PN 16

1,7 2,1 2,6 2,8 3,3 4,0 5,0 6,7 9,4 12,6 17,5 22,1 —

37,4 57,6 57,4 76,8 91,4 127,0 185,0349,6504,2

PN 25

1,7 2,1 2,6 2,8 3,8 4,7 6,0 8,7 13,0 17,725,4 33,2—

47,2 68,090,0

123,0149,0201,0285,0

——

Weight in kg ≈one flangeDimensions in mm

Dimensions and weights

DN

80 100 125 150 200 250 300 350 400 500 600 700 800 9001000120014001600

100

7,6 8,610,613,218,425,534,0———————————

200

9,2 10,7 13,3 16,5 23,0 32,0 41,5 48,5 57,5 78,5108,0

———————

300

10,8 12,7 15,9 19,7 27,5 38,0 49,5 58,5 69,5 94,5129,0169,0

——————

400

12,4 14,8 18,6 23,0 32,0 44,0 57,0 68,0 81,0111,0150,0196,0250,0300,0366,0468,0738,0

1018,0

500

14,1 16,8 21,0 26,0 37,0 50,5 65,0 77,5 92,5127,0171,0223,0284,0340,0414,0525,0812,0

1111,0

600

15,7 18,8 24,0 29,5 41,5 56,5 73,0 87,5104,0143,0192,0250,0317,0380,0462,0581,0886,0

1204,0

700

17,3 21,0 26,5 32,5 46,0 62,5 80,5 97,0116,0159,0214,0276,0350,0420,0510,0638,0960,0

1297,0

800

18,9 23,0 29,0 36,0 50,5 68,5 88,5107,0127,0175,0235,0303,0383,0461,0557,0694,0

1034,01390,0

900

20,5 25,0 32,0 39,0 55,5 75,0 96,5116,0139,0191,0256,0330,0416,0501,0605,0751,0

1108,01483,0

1000

22,0 27,0 34,5 42,5 60,0 81,0104,0126,0151,0207,0277,0357,0450,0541,0653,0807,0

1182,01576,0

Weight in kg ≈

Length L in mm

Page 25: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

5150

22.2

Marking forductile cast iron fittings

All German manufacturers member of the “Fachgemeinschaft Guss-Rohrsysteme” (FGR-EADIPS) association mark all ductile cast iron products manufactured by them with the label “FGR”, which is equivalent to a quality mark. In addition, fittings are marked with the DVGW sign, nominal diameter, the casting day and bends with the respective angles in degrees.

Flanged fittings bear a cast-on or stamped indication of the nominal pressure ranges PN 10 up to PN 40. Socket fittings are not marked with the nominal pressure range. The material “ductile cast iron” is identified by 3 dots (ll

l ), arranged in a triangle symbol, positioned on the exterior surface of the fittings.

In special cases, further indications may be provided.

Ductile cast iron fittings will be delivered as follows:with TYTON® socketwith TYTON® socket and pre-chamber for thrust resisting joint NOVO-SIT®

with screw-gland socket jointwith bolted-gland socket jointwith flanges

Ductile cast iron socket fittings with TYTON® sockets ( flangeless ) for use in potable water pipelines are designed for operating pressures as given in EN 545.

Ductile cast iron fittings with screw-gland or bolted-gland sockets for use in potable water pipelines are designed for operating pressures up to 16 bar. Higher pressures on request.

Ductile cast iron fittings with one flange or more, for the use in potable water pipelines are designed for operating pressures as given in EN 545.The operating pressure has to be mentioned in orders, because the flange dimensions of these fittings vary depending on the nominal pressures rates.

Ductile cast iron fittings for the use in sewerage pipelines as per EN 598 are designed for operating pressures up to 16 bar. Higher pressures on request.

Ductile cast iron fittings for the use in gas pipelines as per EN 969 are available for operating pressures up to 16 bar on request.

> All indicated weights are valid for fittings with cement-mortar linings <

Coating: see page 47 “Inside and outside protection”.

Information aboutductile cast iron fittings

Page 26: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

52

22.2

53

Flanged sockets – Ewith screw-gland or TYTON® socket

* acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN

40*

50* 65*

80

100

125

150

200

250

300

350400450500600700800

Lu

100 150 600 150 150 600 600 1000 130 250 600 135 600 135 600 140 600 145 600 150 600 800 600 600 600 600 600 6001000

e

7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,2 7,2 7,2 7,5 7,5 7,8 7,8 8,4 8,4 9,0 9,0 9,6 9,6 9,610,210,811,412,013,214,415,6

PN 10

5,9 6,0 11,0 8,0 10,5 17,0 17,5 25,5 10,3 14,0 17,0 14,6 26,0 16,7 28,5 23,0 40,0 33,5 61,5 40,0 96,0 100,0 128,0 135,0 194,0 163,0 270,0 453,0603,0

Weight in kg ≈ with TYTON® socket

PN 16

5,9 6,0 11,0 8,0 10,5 17,0 17,5 25,5 10,3 14,0 17,0 14,6 26,0 16,7 28,5 23,0 40,0 33,5 61,5 40,0 96,0100,0130,0140,0203,0176,0295,0466,0621,0

Dimensions and weights

Page 27: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

54

22.2

55

Flanged sockets – EU Flanged sockets – EU

DN

40* 50* 65* 80 100 125 150 200 250

Lu

76 78 80130130135135140145

z 2)

50 50 50 86 87 91 92 97102

Tol.

± 30± 30± 30± 40± 40± 40± 40± 40± 40

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0

PN 10

4,3 5,4 6,0 8,4 10,513,216,021,631,5

PN 16

4,3 5,4 6,0 8,4 10,513,216,021,631,5

PN 10

— — —

8,6 10,5 14,5 16,0 24,0 32,5

Dimensions in mm

Compensation lengthwith screw-gland

socketwith

TYTON® socketwith bolted-gland

socket

Weight in kg ≈ 1)

PN 16

— — —

8,6 10,5 14,5 16,0 24,0 32,5

PN 10

— — — — — — — — —

PN 16

— — — — — — — — —

* acc. to manufacturer’s standard1) without screw- or bolted-gland rings2) Nominal dimension for laying. If flanged sockets are applied as gate valve dismantling joints,

the moving tolerance has to be limited to 10 mm.on request also with Standard socket and Universal pre-chamber

Dimensions and weights

1) without screw- or bolted-gland rings2) Nominal dimension for laying. If flanged sockets are applied as gate valve dismantling joints,

the moving tolerance has to be limited to 10 mm.on request also with Standard socket and Universal pre-chamber

l

DN

300 350 400 450 500 600 700 800 9001000120014001600

Lu

150 155 160 165170180190 200 210 220240310330

z 2)

107112 117122127137147157 167 177197250265

Tol.

± 40± 40 ± 40 ± 40± 40± 40± 40± 40 ± 40 ± 40 ± 40± 50± 60

e

9,610,210,811,412,013,214,415,616,818,020,422,825,2

PN 10

41,0 50,0 56,5 91,0———— — — ———

PN 16

41,051,062,092,0—— — — —— ———

PN 10

45,0 54,0 66,0 77,0 95,5 122,5 176,6 242,0 281,0 340,0 536,0

——

Dimensions in mm

Compensation lengthwith screw-gland

socketwith

TYTON® socketwith bolted-gland

socket

Weight in kg ≈ 1)

PN 16

45,0 58,0 70,0 91,0 109,0 145,5 160,0 262,0 278,0 355,0 600,0900,0

1200,0

PN 10

——

70,5 88,0103,0 142,0194,0 189,0 242,0 320,0———

PN 16

——

74,0 95,0 119,0 163,5207,0 208,0 263,0370,0

———

Page 28: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

5756

22.2

Collars – U Flanged spigots – F

* acc. to manufacturer’s standard Operating pressures see page 50 1) without screw- or bolted-gland rings Novo socket types see page 219 on request also with Standard socket and Universal pre-chamber

DN

40* 50* 65* 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000 1200 1400 1600

ø d1

56 66 82 98 118 144 170 222 274 326 378 429 480 532 635 738 842 945 1048125514621668

L

300300400350360370380400420440460480500520560600600600600600710780

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

PN 10

5,5 6,2 9,5 8,5 10,5 14,0 17,5 25,5 39,5 47,6 62,1 80,5132,0121,0193,3229,5314,3357,0380,0462,0——

PN 16

5,5 6,2 9,5 8,5 10,5 14,0 17,5 25,5 39,5 47,6 65,9 88,6149,0140,4208,9227,0320,0384,0

—526,0840,0

1260,0

Dimensions in mm Weight in kg ≈

200200200215215220225230240250260270280290310330330330330330390430

PN 25

———

8,5 13,5 17,5 18,5 35,1 49,0 58,0 70,0106,4150,0146,3228,0—

395,3—————

PN 40

———

8,5 15,0 18,0 26,5 40,0 59,5 73,4 92,5131,8—

169,0————————

Dimensions and weights

DN

40 50 65 80100125150200250300350400450500600700800900

1000120014001600

ø d

67 78 93109130156183235288340393445498550655760865970

1075128514881694

Lu

155155155160160165165170175180185190195200210220230240250270340360

DIN 28 601

with screw-gland sockets

7,0 8,5 11,0 8,1 9,7 12,5 15,2 23,2 31,3 38,5 49,5 63,2 87,0123,1

————————

DIN 28 602

with bolted-gland sockets

————

14,5—

24,8 30,0 37,5 51,0 65,0 73,5 97,0122,1167,4216,0256,7313,0421,2558,0840,0

1087,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Page 29: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

5958

22.2

Double socket bends 90° – MMQ Single socket bends 90° – MQacc. to manufacturer’s standard

Operating pressures see page 50 1) without screw- or bolted-gland ring on request also with Standard socket and Universal pre-chamber

DN

40 50 65 80100125150200250300350400500600700800

L

200 300 370 312 333 374 419 491 583 660 580 625 715 805 9001080

Lu

60,0150,0215,0102,4123,0148,8174,5226,0280,0330,0410,0430,0550,0645,0720,0800,0

with screw-gland

socket

9,5 11,0 15,0 8,0 10,8 16,1 23,8 43,2 70,0 96,0

——————

with bolted-gland

socket

——————————

150,0156,0225,0 325,0482,0651,0

with

TYTON® socket

———

9,0 11,2 18,4 25,4 43,8 76,1 83,2 139,0 186,3 235,4 314,0 473,0 644,5

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,812,013,214,415,6

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Operating pressures see page 50 1) without screw- or bolted-gland rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN

40* 50* 65*

80 100 125 150 200 250 300

350* 400* 450* 500* 600* 700* 800* 900* 1000* 1200*

Lu

60,0 150,0 85,0 100,0 125,0 150,0 175,0 225,0 280,0 330,0 410,0 430,0 457,0 550,0 645,0 720,0 800,0 950,01050,01205,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 11,4 12,0 13,2 14,4 15,6 16,8 18,0 20,4

with screw-gland

sockets

8,010,514,0 8,610,515,119,231,354,069,8——————————

with

TYTON® sockets

———

8,5 11,0 16,2 20,5 32,4 52,9 72,4 104,8 128,0 208,0 214,4 314,3 480,0 650,0 869,01060,01600,0

with

bolted-gland sockets

————————————

187,0262,0357,0198,0662,0

———

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Page 30: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

6160

22.2

Double socket bends 45 ° – MMK 45Single socket bends 45° – MK 45acc. to manufacturer’s standard

Operating pressures see page 50 1) without screw- or bolted-gland rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw- or bolted-gland ring on request also with Standard socket and Universal pre-chamber

DN

40 50 65 80100 125 150200250300350

400450500600700800

L

210252303265274301331374300315345368420405529610625

Lu

135174223 55 65 76 87109130155175200220240285380370

with screw-gland

socket

7,5 10,0 14,5 7,0 9,8 14,9 19,4 31,3 42,0 56,2 68,0 93,0106,0

————

with bolted-gland

socket

——————————

79,0105,0

—143,0265,0

——

with

TYTON® socket

———

8,4 10,8 16,2 20,5 33,5 44,3 59,4 68,0 91,0106,0187,0250,5441,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,6

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weightsDN

40* 50* 65

80 100 125 150 200 250 300 350 400 450 500

600 700 800

9001000120014001600

Lu

TYTON®

screw-gland socket

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

with screw-gland

sockets

8,0 8,5 5,6 7,1 9,212,316,324,534,548,570,293,9——————————

with

TYTON® sockets

———

8,3 10,3 14,5 18,9 25,9 38,9 55,1 81,0 91,3 139,9 145,8 196,6 312,1 496,8 578,0 768,0

1100,01572,0

with bolted

gland sockets

——————————

81,0* 106,0*

—180,4300,2

———————

with

Standard sockets

——————————

81,0* 106,0*

—180,4300,2

————— —

2096,0

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

138,0145,0 50,0 55,0 65,0 75,0 85,0110,0130,0150,0175,0200,0220,0240,0

415,0460,0550,0515,0—

Lu

bolted gland socket

Lu

Standard socket

285,0330,0370,0

370,0380,0440,0

—————————————————————

565,0

Page 31: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Operating pressures see page 50 1) without screw- or bolted-gland ring on request also with Standard socket and Universal pre-chamber

DN

40 50 65 80100125150200250300350400500600700800

L

201243298253260283309345270280295308335412480510

Lu

126165218 44 50 57 65 80 95110125140170200250260

with screw-gland socket

7,510,014,5 7,410,114,018,629,236,748,057,071,0————

with bolted-gland socket

——————————

64,0 80,0120,0185,0

——

with

TYTON® socket

———

7,4 10,8 15,1 20,0 30,8 38,9 52,9 56,0 76,5 107,0 178,0 286,0 350,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,812,013,214,415,6

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

62

22.2

63

Double socket bends 30° – MMK 30acc. to DIN 28 650

Single socket bends 30° – MK 30acc. to manufacturer’s standard

Operating pressures see page 50 1) without screw- or bolted-gland rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN

40* 50* 65*

80 100 125 150 200 250 300 350

400 450*

500 600

700 800 90010001200

103107113 45 50 55 65 80 95110125140255170200

260290320380

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,4

with screw-gland

sockets

8,0 10,0 13,0 6,8 9,711,615,723,831,345,963,784,8————————

Weight in kg ≈ 1) Dimensions in mm

with TYTON® sockets

———

7,8 9,9 14,3 18,4 23,8 34,6 52,4 74,5 89,1145,0123,7166,9279,0370,0496,0652,0

1020,0

with bolted-gland

sockets

——————————

74,0* 94,0*

—145,5193,0

—————

Dimensions and weights

230 250

Lu

TYTON® screw-gland socket

Lu

bolted-gland socket

Page 32: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

6564

22.2

Double socket bends 22 1/2° – MMK 22Single socket bends 22 1/2° – MK 22acc. to manufacturer’s standard

Operating pressures see page 50 1) without screw- or bolted-gland rings on request also with Standard socket and Universal pre-chamber

DN

40 50 65 80100125150200250300350400500600700800

L

179240232248253274299331260265270278300357420455

Lu

142162152 38 43 49 55 66 75 90100110135155190205

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,812,013,214,415,6

with screw-gland

socket

7,510,012,0 7,0 9,213,517,327,036,047,553,065,0————

with

TYTON® socket

———

8,1 9,7 15,1 18,4 29,2 37,8 50,2 52,0 76,7 97,0163,0336,0460,0

with bolted-gland

socket

——————————

60,0 74,0110,0185,0

——

Dimensions in mm Weight in kg ≈ 1)

Dimensions and weights

Operating pressures see page 50 1) without screw- or bolted-gland rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN

40* 50* 65

80 100 125 150 200 250 300 350 400 450 500 600

700 800

9001000120014001600

87,0 90,0 35,0 40,0 45,0 50,0 55,0 65,0 75,0 90,0100,0110,0120,0135,0155,0

195,0220,0240,0285,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

with

screw-gland sockets

7,5 9,512,5 4,9 8,611,514,621,030,542,162,174,5——————————

with

TYTON® sockets

———

7,8 9,6 13,5 17,8 22,7 33,5 50,8 67,0 83,2128,0 112,9 154,4 242,0 311,0 422,0 593,0 820,01224,0

with

bolted-gland sockets

——————————

70,0* 88,0*

—127,0179,0

———————

with

Standard sockets

—————————————————————

1607,0

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Lu

TYTON®

screw-gland socket

Lu

bolted-gland socket

Lu

Standard socket

175,0

260,0

190,0

—————————————————————

280,0

Page 33: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

6766

22.2

Double socket bends 11 1/4° – MMK 11Single socket bends 11 1/4° – MK 11acc. to manufacturer’s standard

Operating pressures see page 50 1) without screw- or bolted-gland ring on request also with Standard socket and Universal pre-chamber

DN

40 50 65 80100125150200250300350400500600700800

L

175171187240243261284311255260235238250287340375

Lu

83131 67 30 33 36 40 46 50 60 65 70 85 95110125

with screw-gland

socket

6,5 8,511,5 7,1 9,212,416,724,833,544,047,056,0————

with bolted-gland socket

——————————

54,0 65,0 95,0 185,0 258,0 292,0

with

TYTON® socket

— — —

7,6 9,8 14,0 18,0 27,0 37,8 47,0 46,0 66,9 83,2 163,0 249,0 286,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,812,013,214,415,6

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Operating pressures see page 50 1) without screw- or bolted-gland rings * acc. to manufacturer’s standard on request also with Standard socket and Universal pre-chamber

DN

40* 50* 65

80 100 125 150 200 250 300 350 400 450 500 600

700 800 9001000120014001600

63,0 65,0 25,0 30,0 35,0 35,0 40,0 45,0 50,0 60,0 65,0 70,0 70,0 85,0 95,0

110,0 120,0 130,0150,0

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 11,4 12,0 13,2 14,4 15,6 16,8 18,0 20,4 22,8 25,2

with screw-gland

sockets

7,0 9,011,5 6,5 8,110,613,420,528,138,349,767,5——————————

with

TYTON® sockets

7,6 8,6 13,0 16,7 21,1 30,2 45,4 62,1 73,4 92,5 86,4 125,3 201,0 294,3 350,0 506,0 650,01078,0

with

bolted-gland sockets

———————

64,0* 79,0*

—120,5 158,0 164,0 283,0

—————

with

Standard sockets

——————————————————

1416,0

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Lu

TYTON®

screw-gland socket

Lu

bolted-gland socket

Lu

Standard socket

95,0

160,0

110,0

—————————————————————

175,0

Page 34: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

6968

22.2

Double socket tees with flanged branch – MMADouble socket tees with flanged branch – MMA

Operating pressures see page 50 1) without screw- or bolted-gland ring * acc. manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN 1

40* 50*

65*

DN 2

404050405065

Lu

155170170190190190

l u

140150150165165165

e1

7,0 7,0 7,0 7,0 7,0 7,0

e2

7,0 7,0 7,0 7,0 7,0 7,0

with screw-gland

sockets

10,512,513,516,016,518,0

with bolted-gland

sockets

——————

with

TYTON® sockets

——————

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Operating pressures see page 50 1) without screw rings * acc. manufacturer’s standard on request also with Standard socket and Universal pre-chamber

DN 1

80

100

125

150

200

DN 2

40* 50* 65*

80 40* 50* 65* 80*

100 40* 50* 80*

100 125

40* 50* 80*

100 125*

150 40* 50* 80*

100 125*

150 200

Lu

170170170170190190190190190195195195195225195195195195255255200200200200 255 255 315

l u

155160160165170170175175180185185190195200195200205210220220230230235240250250260

e2

7,07,07,07,07,07,07,07,07,27,07,07,07,27,57,07,07,07,27,57,87,07,07,07,27,57,88,4

e1

7,0

7,2

7,5

7,8

8,4

with screw-gland

sockets

11,813,012,515,113,014,015,016,217,417,317,518,920,522,121,622,723,824,828,030,827,830,031,332,437,038,946,4

with bolted-gland

sockets

———————————————————————————

Weight in kg ≈ 1) Dimensions in mm

with TYTON® sockets

13,013,013,514,014,915,716,917,518,619,420,021,622,724,323,824,325,927,031,332,930,831,332,934,041,043,249,7

Page 35: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

7170

22.2

Double socket tees with flanged branch – MMADouble socket tees with flanged branch – MMA

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

➜➜

DN 1

250

300

350

400

DN 2

40* 80*

100150 200 250

80*100150 200

250* 300

80*100

150* 200

250* 300*

350 80*

100150 200

250* 300

350* 400

Lu

200200200260 315 375205205260320430435205205325325495495495210210270325440440560560

lu

265265270280290300295300310320330340325330340350360370380355360370380390400415420

e1

9,0

9,6

10,2

10,8

e2

7,0 7,0 7,2 7,8 8,4 9,0 7,0 7,2 7,8 8,4 9,0 9,6 7,0 7,2 7,8 8,4 9,0 9,610,2 7,0 7,2 7,8 8,4 9,0 9,6 10,2 10,8

with screw-gland

sockets

36,0 40,0 42,0 52,4 53,5 62,5 51,8 52,9 65,9 72,4 89,0 90,7 63,0 62,0 82,0 89,5101,0114,0

119,0 / 122,0 79,9 81,0 93,4 109,0 118,5 125,5

147,0 / 150,0158,0 / 172,0

with bolted-gland

sockets

———————————————————————————

with

TYTON® sockets

45,4 48,0 48,1 56,2 60,5 75,6 58,9 60,5 70,7 70,0 91,8 95,6 73,4 73,4 89,1 97,2 98,0114,0

119,0 / 125,0 92,9 94,0105,8113,9115,0132,3

147,0 / 150,0177,0 / 170,0

Weight in kg ≈ 1) Dimensions in mm

DN 1

400*

450*

500

DN 2

80100150 200 300 400 80 100 150 200 250 300 350 400 450

80*100150200

300*400500

Lu

210210270325440560215215270300450450560560620215215330330450565680

lu

355360370380400420390390400410420430450450460415420430440460480500

e1

10,8

11,4

12,0

e2

7,0 7,2 7,8 8,4 9,6 10,8 7,0 7,2 7,8 8,4 9,0 9,6 10,2 10,8 11,4 7,0 7,2 7,8 8,4 9,6 10,8 12,0

with screw-gland

sockets

——————————————————————

with bolted-gland

sockets

94,0 95,0104,0114,0139,0

164,0 / 169,0—————————

110,7110,7130,0140,4174,4

215,0 / 220,0 244,0

with

TYTON® sockets

——————

110,0110,0128,0132,0145,5161,5

220,0 / 226,0230,0 / 236,0260,0 / 267,0

103,0104,0138,0140,0156,0

188,0 / 193,0222,0 / 236,0

Weight in kg ≈ 1) Dimensions in mm

Page 36: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

7372

22.2

Double socket tees with flanged branch – MMADouble socket tees with flanged branch – MMA

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw rings * acc. manufacturer’s standardon request also with Standard socket and Universal pre-chamber

l➜

DN 1

600

700

800

DN 2

80* 100* 150*

200 300*

400 500*

600 80* 100* 150*

200 250* 300* 350*

400 500* 600*

700 80* 100* 150*

200 250* 300* 350*

400 500*

600800

Lu

340340340340460570800800345345345345575575575575925925925350

350 350 350 580 580 580 580 1045 1045 1045

lu

475470480500520540550580510510520525535540555555570585600570570580585590600615615630645 675

e1

13,2

14,4

15,6

e2

7,0 7,2 7,8 8,4 9,6 10,8 12,0 13,2 7,0 7,2 7,8 8,4 9,0 9,610,210,812,013,214,4 7,0 7,2 7,8 8,4 9,0 9,6 10,2 10,8 12,0 13,2 15,6

with screw-gland

sockets

——————————————————————————————

with bolted-gland

sockets

182,5 183,6 189,0 187,6 233,8

286,0 / 256,5340,0 / 336,4361,0 / 386,0

266,0 278,0 263,0 262,0 287,0 381,0

276,0 / 279,0381,0 / 392,0468,0 / 482,0599,0 / 523,0550,0 / 563,0

319,0 339,9 322,9 298,0 433,0 408,2

432,0 / 435,0 / 429,8 / 685,8 / 685,8755,0 / 755,0

with TYTON® sockets

169,0170,0174,0178,0210,0

240,0 / 245,0315,0 / 330,0323,0 / 339,0

248,0260,0263,0266,0269,0340,0

258,0 / 261,0363,0 / 374,0450,0 / 464,0481,0 / 505,0532,0 / 545,0

307,0324,0332,0342,0415,0431,0

420,0 / 423,0398,0 / 437,0614,0 / 628,0630,0 / 640,0716,0 / 743,0

Weight in kg ≈ 1) Dimensions in mm

DN 1

900

1000

1200

1400

1600

DN 2

80* 100* 150*

200 250* 300*

400600

700*900

150*200

250*400600

1000 200* 400* 500*

600 700*

800 900*1000600800

1000600800

10001200

Lu

355

590

1170

360360380595

12901290840840840840

10701070130013001030126014951040127515051740

lu

630635640645645660675705720750700705710735765825835835850885900915930945980

101010401090112011501180

e1

16,8

18,0

20,4

22,8

25,2

e2

7,0 7,2 7,8 8,4 9,0 9,6 10,8 13,2 14,4 16,8 7,8 8,4 9,0 10,8 13,2 18,0 8,4 10,8 12,0 13,2 14,4 15,6 16,8 18,0 13,2 15,6 18,0 13,2 15,6 18,0 20,4

with

Standard sockets

—————————————————————— —————

2130,02359,02643,02938,0

with bolted-gland

sockets

———————————————————————————————

with

TYTON® sockets

400,0470,0472,0

/ 540,0 475,0 /

/ 561,0567,0 / 572,0810,0 / 820,0 / 868,0930,0 / 898,0 / 650,0

561,0 / 691,0 /

639,0 / 644,0 1162,0 / 1205,0 / 1248,0

/ 949,0 / 960,0 / 969,0 / 985,0

/ 1135,0 / 1160,0 / 1296,0 / 1428,0 / 1655,0 / 1850,0 / 2100,0

————

Weight in kg ≈ 1) Dimensions in mm

Page 37: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

7574

22.2

All socket tees – MMBAll socket tees – MMB

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN 1

40* 50*

65*

80

100

125

DN 2

40 40

50* 40 50

65* 40* 50* 65*

80 40* 50* 65* 80*

100 40* 50* 80*

100 125

Lu

156170170190190190170170170170190190190190190195195195195225

lu

78 83 85 90 92 95 80 80 80 85 90 90 90 95 95100105105110110

e1

7,0 7,0

7,0

7,0

7,0 7,2

7,5

e2

7,0 7,0 7,0 7,0 7,0 7,0 7,0

7,0 7,0 7,0 7,0 7,0 7,27,07,0 7,07,27,5

with screw-gland

sockets

11,012,513,516,017,018,010,110,511,013,011,712,513,014,614,916,216,516,618,119,4

with

TYTON® sockets

——————

10,811,9—

14,014,015,113,015,117,018,418,520,521,623,2

with

Standard sockets

————————————————————

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

DN 1

150

200

250*

300*

DN 2

40* 50* 80*

100 125* 150

40* 50*

65 80 100

125* 150 200 80 100 125 150 200 250 50 65 80 100 125 150 200 250 300

Lu

195195195195255255200200200200200255255315200200200260315375205205205205205320320430430

lu

115115120120125125140140140145145145150155170175175180185190195195195200200200205210215

e1

7,8

8,4

9,0

9,6

e2

7,0 7,0 7,0 7,2 7,5 7,8 7,0 7,0 7,0 8,1 8,4 8,8 9,1 9,8 7,0 7,2 7,5 7,8 8,4 9,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6

with screw-gland

sockets

19,4 20,0 22,7 22,7 25,0 27,0 25,5 26,5 28,0 30,8 31,9 35,0 37,8 40,0 38,0 38,9 43,0 44,5 51,5 61,0 44,0 44,5 50,0 47,0 55,0 59,4 61,0 74,0 81,0

with

TYTON® sockets

22,7 22,5 24,8 25,4 30,2 30,8 30,2 31,3 28,0 38,4 31,9 37,8 42,1 45,9 45,4 46,4 46,4 51,8 56,2 65,9 44,0 44,5 56,7 58,3 58,4 62,4 66,4 82,1 92,1

with

Standard sockets

—————————————————————————————

Weight in kg ≈ 1) Dimensions in mm

Page 38: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

7776

22.2

All socket tees – MMBAll socket tees – MMB

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN 1

350*

400*

450*

500*

DN 2

80100200250300350 8010015020025030040080100150200250300350400450 80100125150200250300350400500

Lu

205205325495495495210210270440440440560 215 215 330 330 450 450 560 560 620 215 215 215 330 330 450 450 565 565 680

lu

220220240245250260245245250260265270285 270 270 280 280 290 290 305 320 380 295 295 295 305 305 315 320 330 335 350

e1

10,2

10,8

11,4

12,0

e2

7,0 7,2 8,4 10,5 9,6 10,2 7,0 7,2 7,8 8,4 9,0 9,6 10,8 7,0 7,2 7,8 8,4 9,0 9,610,210,811,4 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 12,0

with screw-gland

sockets

74,0 79,0 91,0 103,0 115,0 128,0 83,5 86,5 94,0 100,0 108,0 122,0 145,0

———————————————————

with

TYTON® sockets

74,0 79,0 88,0 118,8 126,4 125,0 95,5 93,4 94,0 111,8 118,8 123,7 175,5 110,0 110,0 128,0 146,5 155,0 162,5 174,0 180,0 185,0 128,0 131,0 134,0 136,0 145,0 155,0 170,0 183,0 195,0 233,3

with

Standard sockets

————————————————————————————————

Weight in kg ≈ 1) Dimensions in mm

DN 1

600*

700*

800*

900*

DN 2

125150200250300350400500600150200250300400500

6002)

700125300400600700800500600900

Lu

340340340460460570570800800345345575575575925925925350580580104510451045117011701170

lu

345345365365365375380390400395400410415425435430455475470480490500520535540610

e1

13,2

14,4

15,6

16,8

e2

7,5 7,8 8,4 9,0 9,610,210,812,013,2 7,8 8,4 9,0 9,6 10,8 12,0 13,2 14,4 7,5 9,6 10,813,2 14,4 15,6 12,0 13,2 16,8

with screw-gland

sockets

——————————————————————————

with

TYTON® sockets

189,0 197,0 205,0 222,0 231,0 236,0 245,0 325,0 340,0253,0264,0275,0370,0355,0445,0545,0497,0408,0490,0520,0760,0805,0820,0500,0525,0850,0

with

Standard sockets

——————————————————————————

Weight in kg ≈ 1) Dimensions in mm

Page 39: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

78

22.2

All socket tees – MMB

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Double socket tapers – MMR

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN 1

50* 65*

80

100

DN 2

404050

40*50

65* 40* 50* 65*

80

Lu

200200200200110200150150120 90

e1

7,0 7,0

7,0

7,2

e2

7,07,07,07,07,07,07,07,07,07,0

with screw-gland

sockets

7,8 7,810,513,5 5,415,214,0 7,6 7,0 8,1

with

TYTON® sockets

— — — — — — — — — 9,2

Dimensions and weights

Weight in kg ≈ 1) Dimensions in mm

79

l

DN 1

1000*

1200*

1400*

1600*

DN 2

150200250300400600800900

1000300600700800900

1200600800900

100012001400600800900

1000120014001600

Lu

360 360 595 595 5951290129012901290 840 84010701070130015251030126014951975172519601040127512601505174019702200

lu

570580590600600640660680680730750750760760760840865875885905930940965975985

101010301050

e1

18,0

20,4

22,8

25,2

e2

7,8 8,4 9,0 9,610,813,215,616,818,0 9,613,214,415,616,820,413,215,616,818,020,422,813,215,616,818,020,422,825,2

with screw-gland

sockets

————————————————————————————

with

TYTON® sockets

507,0 508,0 597,0 613,0 619,01028,01102,01108,01115,0 940,0 980,01140,01150,01285,01536,01770,01990,02120,02140,02360,03000,0

———————

with

Standard sockets

—————————————————————

2150,02450,02520,02650,02950,03400,03900,0

Weight in kg ≈ 1) Dimensions in mm

Page 40: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

8180

22.2

Double socket tapers – MMRDouble socket tapers – MMR

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

Operating pressures see page 50 1) without screw rings * acc. to manufacturer’s standardon request also with Standard socket and Universal pre-chamber

DN 1

125

150

175200

250

300

350

DN 2

65* 80100 65 80100125150 80100125150175 80100125150200 80100150200250150200250300

Lu

170140100180190150100200280250200150200300300300250150300300350250150500360260160

e1

7,5

7,8

8,18,4

9,0

9,6

10,2

e2

7,0 7,0 7,2 7,0 7,0 7,2 7,5 7,8 7,0 7,2 7,5 7,8 8,1 7,0 7,2 7,5 7,8 8,4 7,0 7,2 7,8 8,4 9,0 7,8 8,4 9,0 9,6

with screw-gland

sockets

9,6 9,9 9,814,012,313,412,636,525,918,317,517,830,033,029,026,528,030,229,555,141,037,836,778,048,047,045,0

with

TYTON® sockets

— 11,311,813,015,115,715,7—

22,720,522,722,1—

33,029,031,334,634,629,536,250,243,243,778,048,047,045,0

Weight in kg ≈ 1)Dimensions in mm

l

DN 1

400

450

500

600

700

800

900

1000

120014001600

DN 2

200250300350300

350*400250300

350* 400*

450300350

400* 500*

400 500* 600*

500600700700800

600*800900

10001200

1200*1400

Lu

400360260160500500160500500500500500500600460500500500500500480280480280880480280480360560360

e1

10,8

11,4

12,0

13,2

14,4

15,6

16,8

18,0

20,422,825,2

e2

8,4 9,0 9,610,2 9,610,210,8 9,0 9,610,210,812,0 9,610,210,812,010,812,013,212,013,214,414,415,613,215,616,818,020,420,422,8

with screw-gland

sockets

79,9 73,5 68,0 70,0139,3129,0156,6101,0133,0150,0139,5267,0

——————————————— ————

with

TYTON® sockets

65,0 73,5 68,0 70,0120,0129,0 75,0127,4134,0143,6150,7155,0157,0184,0185,8186,8

296,0341,5252,5275,0288,0296,0382,0347,0476,0460,0420,0652,0880,0

1200,01260,0

Dimensions in mm Weight in kg ≈ 1)

Page 41: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

8382

22.2

l➜

Single socket tees with flanged branch – Aacc. to manufacturer’s standard

Single socket tees with flanged branch – Aacc. to manufacturer’s standard

Operating pressures see page 50 1) without screw ringon request also with Standard socket and Universal pre-chamber

DN 1

40 50

80

100

DN 2

40 40 50 40 50 80 40 50 65 80 100

Lu

400400400400400400400400400400400

l

150150150180180180200200200200200

z

78 85 85106106106120120120120120

e1

7,07,0

7,0

7,2

e2

7,07,0

7,0

7,07,07,07,07,2

with screw- gland socket

10,010,512,012,313,015,115,715,516,017,818,7

with

TYTON® socket

———12,313,015,716,215,516,018,418,8

Weight in kg ≈ 1) Dimensions in mm

Dimensions and weights

Operating pressures see page 50 1) without screw ringon request also with Standard socket and Universal pre-chamber

DN 1

125

150

200

300

4001000

DN 2

40 50 80 100 125 40 50 80 100 125 150 50 80 100 150 200 80 100 150 400600

Lu

425 425 425 425 425 450 450 450 450 450 450 600 600 600 600 600 800 800 80010001770

l

190190190195200205205205210210210240240250275300300300300450825

z

112112112112112128128128128128128190190190240240260260260330645

e1

7,5

7,8

8,4

9,6

10,818,0

e2

7,0 7,0 7,0 7,2 7,5 7,0 7,0 7,0 7,2 7,5 7,8 7,0 7,0 7,2 7,8 8,4 7,0 7,2 7,810,812,0

with screw- gland socket

17,5 18,0 20,0 21,6 26,0 24,8 24,0 26,4 25,0 28,5 30,4 46,0 50,0 55,0 58,0 64,8119,5121,0126,5186,0—

with

TYTON® socket

17,5 18,0 22,5 23,5 26,0 23,0 24,0 28,0 29,2 28,5 30,4 46,0 55,0 51,0 58,0 60,0 119,5 121,0 126,5 186,01160,0

Weight in kg ≈ 1) Dimensions in mm

Page 42: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

8584

22.2

Double flanged bends 90° – QSingle socket tees with socket branch – Bacc. to manufacturer’s standard

Operating pressures see page 50 1) without screw ringson request also with Standard socket and Universal pre-chamber

DN 1

40 80100

150

DN 2

40 80 80100 80100125

Lu

400400400400450450450

lu

105 86 95 95120120125

z

132106120120128128128

e1

7,07,07,2

7,8

8,514,015,016,0 25,0 45,0 28,0

Weight in kg ≈ 1) Dimensions in mm

e2

7,07,07,07,27,07,27,5

Dimensions and weights

* acc. to manufacturer’s standard

DN

40* 50* 65*

80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

L

140 150 165 165 180 200 220 260 350 400 450 500 550 600 700 800 90010001100130013501450

  e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

PN 10

5,5 7,5 10,2 10,2 12,9 18,9 29,3 36,2 58,3 82,1 102,1 144,7 234,0 266,0 370,0 539,0 774,0 745,01010,0

———

PN 16

5,5 7,5 10,2 10,2 12,9 22,0 29,2 36,2 58,3 82,1 111,2 157,7 234,0 277,5 404,0 420,0 720,0 836,01099,01463,02150,02970,0

PN 25

5,5 7,5 10,2 11,0 12,9 22,0 33,5 45,9 81,0116,6155,0217,0241,0305,0346,0575,0672,0—————

PN 40

5,5 7,5 10,2 11,0 12,9 23,2 33,5 53,0101,0144,2199,0284,0308,0375,0458,0———————

Weight in kg ≈ Dimensions in mm

Dimensions and weights

Page 43: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

8786

22.2

Double flanged bends 45° – FFK 45Double flanged duckfoot bends 90° – N

DN

40* 50* 65*

80 100 125 150 200 250 300 350 400 450 500 600

700* 800*

90010001200

L

—150165165180200220260350400450500550600700800900

100011001300

c

— 90 99110125140160190225255290320355385450480540645710845

PN 10

10,5 10,5 16,0 15,7 18,9 27,0 34,6 55,6 84,0 117,7 137,0 263,5

— 374,8 538,9 752,0 926,0——

2311,0

PN 16

10,5 10,5 16,0 15,7 18,9 27,0 38,9 55,6 84,0 117,7 142,0 248,0 295,0 311,0 482,0 705,0 970,0

—1626,0

PN 25

10,5 10,5 16,0 15,7 25,4 22,7 31,0 48,5 80,5 114,0 154,8 209,0 309,0 335,0 506,0 769,0 1086,0

———

PN 40

10,5 10,5 16,0 15,7 25,4 23,9 35,5 60,0 101,0 145,0 201,0 277,0 395,0 402,0 612,0

—————

d

— 150165180200225250300350400450500550600700800900

100010001300

e

— 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 11,4 12,0 13,2 16,0 19,016,818,020,4

Weight in kg ≈Dimensions in mm

Dimensions and weights

* ac

c. to

man

ufac

ture

r’s st

anda

rd

Base borehole on request. * acc. to manufacturer’s standard

350* 400* 500*

215243290

10,511,012,0

64,0 85,0129,0

69,094,5157

85,5114,5178,0

115,5184,5246,0

Short length acc. to manufacturer’s standard

DN

40* 50* 65*

80 100 125 150 200 250 300 350 400 450 500 600 700 800 900100012001400

L

140150165130140150160180350400298324350375426478529581632750775

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,8

PN 10

7,0 9,0 12,0 10,3 12,6 17,5 21,6 32,4 60,9 90,2 96,1 117,2 150,0 185,8 288,0 489,0 403,0

— 727,9

——

PN 16

7,0 9,0 12,0 10,3 12,6 17,5 21,6 32,4 60,9 90,2 102,6129,1 150,0 235,4 347,0 481,0 442,0480,0 685,0

1251,01626,0

PN 25

7,0 9,0 12,0 10,3 —

17,5 33,0 34,0 101,0 87,5 111,0 191,3 180,0 259,2 292,0 392,0 535,0

—1099,0

——

PN 40

7,0 9,0 12,0 10,3 —

18,3 24,5 41,5 83,0 118,0 141,0 196,0248,0264,0397,0

——————

Weight in kg ≈ Dimensions in mm

Dimensions and weights

Page 44: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

8988

22.2

Double flanged bends 22 1/2 ° – FFK 22acc. to manufacturer’s standard

Double flanged bends 30° – FFK 30acc. to manufacturer’s standard

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 90010001200

L

140150165130140150160180 210255165183255220309346383420455530

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,510,210,811,412,013,214,415,616,818,020,4

PN 10

7,0 9,0 12,0 10,0 13,7 15,7 22,7 35,1 47,5 68,0 70,2 85,9143,0129,5230,0360,0439,6

———

PN 16

7,0 9,0 12,0 10,0 13,7 15,7 22,7 35,1 44,0 68,0 71,0 82,5153,0157,5289,0386,0529,0

———

PN 25

7,0 9,0 12,0 10,0

— 18,0 22,0 33,0 90,0 73,0 88,0 104,5 183,0 205,0 289,0 416,0 623,0

—1018,0

PN 40

7,0 9,0 12,0 10,0

— 21,0 25,0 42,0 65,0 100,0 142,0 172,5 251,0275,0298,0

—————

Weight in kg ≈ Dimensions in mm

Dimensions and weights DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

L

140150165130140150160180210255140153209185254284314375410467520560

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

PN 10

7,0 9,0 12,0 10,7 13,6 17,2 22,1 34,6 48,6 68,6 63,7 80,5 135,0 125,8 203,0 327,0418,0

—575,0

———

PN 16

7,0 9,0 12,0 10,7 13,6 17,2 22,1 34,6 48,6 68,6 64,8 95,6 145,0 137,0245,0360,0448,0

—655,0850,0

1278,01805,0

PN 25

7,0 9,0 12,0 10,7

— 29,0 22,0 33,5 48,5 72,0 78,0 97,5 183,0 175,0 247,0 369,0 558,0

—————

PN 40

7,0 9,0 12,0 10,7—

21,0 25,0 42,5 65,5 99,0 132,0 165,5 251,0 345,0 268,0

———————

Weight in kg ≈ Dimensions in mm

Dimensions and weights

Page 45: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

9190

22.2

All flanged tees – TDouble flanged bends 11 1/4 ° – FFK 11acc. to manufacturer’s standard

* acc. to manufacturer’s standard

DN 1

40 50

65

80

100

125

DN 2

40 40 50 40 50 65

40* 50 65 80

40* 50 65 80 100

40* 50* 65 80 100 125

L

280300

330

330

360

400

l

140145150153158165155160160165170170170175180185185185190195200

e1

7,0 7,0

7,0

7,0

7,2

7,5

e2

7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,2 7,0 7,0 7,0 7,0 7,2 7,5

PN 10

10,512,012,515,015,516,514,715,716,417,017,818,719,420,221,3 23,8 24,3 24,8 25,4 27,0 28,1

PN 16

— — — — — —14,715,716,417,017,818,719,420,221,3 23,8 24,3 24,8 25,4 27,0 28,1

PN 25

— — — — — —14,715,716,417,017,222,720,424,522,0 22,5 23,0 24,0 30,0 26,0 32,5

PN 40

— — — — — —14,715,716,417,017,222,718,624,5 22,0 24,0 24,5 25,5 26,0 28,5 31,0

Weight in kg ≈Dimensions in mm

Dimensions and weights

DN

40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 9001000120014001600

L

140150165130140150160180210255105113144135 174 194213280310346405405

e

7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,610,210,811,412,013,214,415,616,818,020,422,825,2

PN 10

7,0 9,0 12,0 10,6 13,7 17,2 23,2 34,6 47,0 69,1 57,2 71,8 108,0106,9 170,0265,0321,8

—588,0

———

PN 16

7,0 9,0 12,0 10,6 13,7 17,2 23,2 34,6 47,0 69,1 53,0 72,5 118,0 140,8222,5292,0396,0397,5656,0870,0

1111,01520,0

PN 25

7,0 9,0 12,0 10,6

— 18,0 22,0 54,5 48,0 69,5 70,0 89,5 145,0 137,0 229,0 370,0490,0

—722,0

———

PN 40

7,0 9,0 12,0 10,6

— 21,0 25,0 39,0 65,0 96,5 138,5 168,5 213,5 237,5 260,5

———————

Weight in kg ≈Dimensions in mm

Dimensions and weights

Page 46: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Gewicht in kg ≈ 9392

22.2

➜➜

All flanged tees – T All flanged tees – T

* acc. to manufacturer’s standard

DN 1

150

175

200

250

300

DN 2

40 50*

65 80 100 125 150 80 100 150 40 50 65 80 100 125 150 200 50 65

80* 100 125

150* 200 250 40 50 65

80* 100 125

150* 200

250* 300

L

440

550

520

700

800

l

195200200205210215220215220230220225230235240245250260255260265275280300325350275280285290300305325350375400

e1

7,8

8,1

8,4

9,0

9,6

e2

7,0 7,0 7,0 7,0 7,2 7,5 7,8 7,0 7,2 7,8 7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 7,0 7,0 7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6

PN 10

29,7 30,8 31,3 31,9 32,4 34,6 32,2 58,0 60,0 64,0 45,4 45,4 45,4 47,4 47,5 50,0 51,3 51,8 68,0 64,0 74,0 75,0 75,0 78,3 88,7 91,8 95,5 96,0 97,0 120,6104,2 113,0 108,0 114,0 121,0 131,0

PN 16

29,7 30,8 31,3 31,9 32,4 34,6 36,2 58,0 60,0 64,0 45,4 45,4 45,4 47,4 47,5 50,0 51,3 51,8 68,0 64,0 74,0 75,0 75,0 78,3 88,7 91,8 95,5 96,0 97,0 120,6104,2 103,0 108,0 114,0 121,0 131,0

PN 25

29,0 35,5 30,5 41,6 42,1 33,5 49,1 — — —

56,5 61,5 64,0 57,5 58,5 61,0 54,0 77,5 97,0 69,0 78,0103,0 75,5110,7 94,0 121,0105,5106,0107,0108,0158,0111,0116,0130,0129,0194,0

PN 40

33,0 40,0 34,5 45,9 35,5 38,0 58,3 — — —

68,5 73,5 74,0 68,5 75,1 73,0 80,0 94,0 97,0 89,0114,0123,1 95,5 128,5 119,0 130,0139,5140,0141,0142,0143,0145,0179,5164,0174,0188,0

Dimensions in mm

* acc. to manufacturer’s standard

DN 1

350

400

450

DN 2

65 80 100 125 150 200 250 300 350

80* 100 125

150* 200

250* 300*

350 400 80 100 150 200 250 300 350 400 450

L

850

900

950

l

315320325325325325325425425350350350350350350450450450375375375375375375475475475

e1

10,2

10,8

11,4

e2

7,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 7,0 7,2 7,8 8,4 9,0 9,6 10,2 10,8 11,4

PN 10

124,0 131,2 130,1 131,8 135,0 137,7 137,7 154,4 150,6 167,4 170,6 171,2 157,0 192,2 185,8 196,0 198,2 198,5 230,0 249,5 232,0 242,0 248,0 282,0 290,0 292,0 313,0

PN 16

120,0 128,0 140,4 129,0 150,1 149,0 145,0 151,5 151,0 180,4 185,8 170,5 169,0 192,2 185,8 200,3 223,6 225,0 243,0 244,0 265,0 258,0 269,0 282,0 309,0 312,0 347,0

PN 25

136,0167,4173,0145,0147,0160,0162,0172,0192,0186,0187,0192,0192,0213,8207,0228,0240,0254,0—————————

PN 40

180,0181,0183,0189,0202,0210,0216,0222,0249,0253,0254,0258,0262,0277,0283,0308,0330,0356,0—————————

Dimensions in mm

Page 47: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

9594

22.2

➜➜

All flanged tees – T All flanged tees – T

* acc. to manufacturer’s standard * acc. to manufacturer’s standard

DN 1

500

600

700

DN 2

80 100 125 150 200

250* 300*

350 400 450 500 80 100 125

150* 200 250 300 350 400 450

500* 600

100* 150*200

250* 300* 350*

400 500* 600*

700

L

1000

1100

650

870

1200

l

400400400400400400500500500500500450450450450450450550550550550550550525525525555555555555600600600

e1

12,0

13,2

14,4

e2

7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 11,4 12,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 10,2 10,8 11,4 12,0 13,2 7,2 7,8 8,4 9,0 9,6 10,2 10,8 12,0 13,2 14,4

PN 10

233,5236,5250,6243,5260,3271,1277,0295,4286,2282,0311,0 358,0373,7307,0386,6319,4395,8392,0374,0380,0385,0395,0413,0325,0326,0355,3401,0404,0411,0490,9570,8572,4635,0

PN 16

234,0265,0260,0273,5291,6278,0285,0303,0346,7319,0317,5389,0408,5356,0388,0417,9386,0440,6427,0434,0443,0460,0513,0351,0352,0393,1429,0432,0441,0467,0563,0658,8622,0

PN 25

281,0305,6285,0288,0292,0298,0305,0325,0356,4354,0356,6374,0375,0378,0380,0410,0416,0444,0460,0507,1476,0493,0480,0473,0474,0486,0519,0524,0537,0566,0675,0704,0726,0

PN 40

348,0349,0353,0362,0362,0370,0391,0408,0447,0458,0469,0468,0469,0473,0476,0502,0508,0530,0574,0594,0609,0623,0659,0

——————————

Weight in kg ≈Dimensions in mm

DN 1

800

900

1000

DN 2

80* 100* 150* 200

250* 300* 350* 400

500* 600

700* 800

100* 200

300* 400

100* 150* 200

300* 400

500* 600

700* 800* 900*

1000

L

690

910

1350

730

950

770

990

1650

l

570570580585585600615615630645650675640645660675700705705735735825825825825825825

e1

15,6

16,8

18,0

e2

7,0 7,2 7,8 8,4 9,0 9,6 10,2 10,8 12,0 13,2 14,4 15,6 7,2 8,4 9,610,8 7,2 7,8 8,4 9,610,812,013,214,415,616,818,0

PN 10

426,5 417,5 457,2 468,7 443,0 574,6 514,0 583,2 737,6 694,4 719,0 756,0 702,0 455,0 544,0 552,0

588,0 591,0 681,0 693,01010,01025,01048,01075,01095,01125,0

PN 16

464,5 471,0 428,0 475,0 481,0 545,0 556,0 580,0 738,0 769,0 771,0 760,0 472,0 477,0 566,0 574,0 635,0 667,0 670,0 760,0 774,01114,01141,01161,01182,01207,01245,0

PN 25

556,5 558,0 562,0 570,0 578,0 640,0 653,0 682,0 841,0 872,0 896,0 967,0 588,0 593,0 685,0 596,0

817,0 820,0 915,0 935,01284,01302,01351,01398,01415,01472,0

PN 40Weight in kg ≈Dimensions in mm

Page 48: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

9796

22.2

Double flanged pieces with 45 ° flanged branch – FFCacc. to manufacturer’s standardAll flanged tees – T

DN 1

50 65 80

100

125

150

DN 2

50 65 65 80 50 80 100 80 100 125 80 100 150

L*

300330360

400

450

500

l1*

70 70 90 80100100 90120 100 100 140 125 110

l*

230260270280300300310330350350360375390

e1

7,0 7,0 7,0

7,2

7,5

7,8

e2

7,0 7,0 7,0 7,0 7,0 7,0 7,2 7,0 7,2 7,5 7,0 7,2 7,8

Weight in kg ≈

16,019,020,023,026,028,030,035,037,040,039,542,056,5

Dimensions in mm

Dimensions and weights

* acc. to manufacturer’s standard * Depending on the pattern equipment, differences in face-to-face dimensions are possible. Please request.

l

DN 1

1200

1400

1600

DN 2

150* 200* 250* 300* 400* 500*

600 700*

800 900*

1000 1200*

600 8001000

1200* 1400*

600 80010001200

1400* 1600*

L

1240

1470

1700

190015501760201522502470160018352065230023002730

l

840840840840855870885900915930945950980

1010104010701100109011201150118012101240

e1

20,4

22,8

25,2

e2

7,88,49,09,610,812,013,214,415,616,818,020,413,215,618,020,422,813,215,618,020,422,825,2

PN 10

PN 16

1240

1292

19002050225026003000240026502900320034003900

PN 25

PN 40Weight in kg ≈ Dimensions in mm

Page 49: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

9998

22.2

Double flanged pieces with 45 ° flanged branch – FFCacc. to manufacturer’s standard

Double flanged pieces with 45 ° flanged branch – FFCacc. to manufacturer’s standard

DN 1

200

250

300

350

400

DN 2

100125150200100125150200250 80100125150200250300100125150200250300350100150200250300350400

L*

600

700

800

900

1000

l1*

170180170130250225200175150320320320300250180130350360340300240230200420420350300250280200

l*

430420430470450475500525550480480480500550620670550540560600660670700580580650700750720800

e1

8,4

9,0

9,6

10,2

10,8

e2

7,2 7,5 7,8 8,4 7,2 7,5 7,8 8,4 9,0 7,0 7,2 7,5 7,8 8,4 9,0 9,6 7,2 7,5 7,8 8,4 9,0 9,610,2 7,2 7,8 8,4 9,0 9,610,210,8

Weight in kg ≈

68,0 70,0 73,0 82,5 90,0 95,0 102,0 106,5 126,5 140,0 141,0 150,0 145,0 153,0 178,0 183,0 180,0 183,0 186,0 190,0 200,0 220,0 225,0 228,0 230,0235,0255,0275,0290,0300,0

Dimensions in mm

l

DN 1

450

500

600

700

800

9001000

DN 2

250300350400450200250300350400450500200250300350400450500600300350500700400500600800900

1000

L*

1000

1000

12001100

13001000100014001500147011001270160020002200

l1*

250200200150150250230180200120130350300250200250100100130200 50 30350350380 50100300500550

l*

75080080085085075077082080088087085080085090085010001000970110095097010501150109010501170130015001650

e1

11,4

12,0

13,2

14,4

15,6

16,818,0

e2

9,0 9,610,210,811,4 8,4 9,0 9,610,210,811,412,0 8,4 9,0 9,610,210,811,412,013,2 9,610,212,014,410,812,013,215,616,818,0

Weight in kg ≈

320,0335,0345,0370,0380,0350,0360,0380,0400,0420,0440,0480,0430,0445,0460,0485,0520,0545,0560,0650,0580,0600,0680,0750,0835,0750,0836,0945,0

1350,01820,0

Dimensions in mm

* Depending on the pattern equipment, differences in face-to-face dimensions are possible. Please request.* Depending on the pattern equipment, differences in face-to-face dimensions are possible. Please request.

Page 50: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

101100

22.2

➜➜

All flanged cross tees – TTacc. to manufacturer’s standard

All flanged cross tees – TTacc. to manufacturer’s standard

DN 1

40 50 65 80100

125

150

DN 2

40 50 65 80 50 80 100 100 125 50 80100 125 150

L

280300330330360

400

440

l

140150165165175175180195 200 200 205 210 215 220

e1

7,0 7,0 7,0 7,0 7,2

7,5

7,8

e2

7,0 7,0 7,0 7,0 7,0 7,0 7,2 7,2 7,5 7,0 7,0 7,2 7,5 7,8

PN 10

11,015,024,024,025,024,828,635,536,737,045,440,543,048,6

PN 16

11,015,024,024,025,024,828,635,536,737,045,440,543,048,6

Weight in kg ≈Dimensions in mm

Dimensions and weights

DN 1

200

250

300

350

400

450

DN 2

50 80100 150 200  80 100 125 150 200 250 80 100 150 200 250 300 100 300 350 80 100 150 200 250 300 350 400 150 450

L

520

700

800

850

900

950

l

230 235 240 250 260 270 275 275 300325 350 295 300 325 350 375 400 325 425 425 345 350 350 350 350 450 450 450 375 375

e1

8,4

9,0

9,6

10,2

10,8

11,4

e2

7,0 7,0 7,2 7,8 8,4 7,0 7,2 7,5 7,8 8,4 9,0 7,0 7,2 7,8 8,4 9,0 9,6 7,2 9,610,2 7,0 7,2 7,8 8,4 9,0 9,610,210,8 7,811,4

PN 10

42,0 48,0 54,0 62,1 71,3102,0104,0107,0111,0124,5119,3135,0148,0152,0177,0174,0203,0136,5184,0209,0164,0168,0173,0177,5197,5212,0234,0268,0306,0314,0

PN 16

42,0 48,0 54,0 62,1 71,3102,0104,0107,0111,0124,5119,3135,0148,0152,0164,0174,0203,0142,5190,0203,0174,0178,0183,0188,0193,0225,0247,0273,0324,0341,0

Weight in kg ≈Dimensions in mm

Page 51: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

103102

22.2

l

Double flanged tapers, concentric – FFRAll flanged cross tees – TTacc. to manufacturer’s standard

Further lengths are available on request. * acc. to manufacturer’s standard

DN 1

500

600

700

DN 2

80150200250300400500150200250300350400500600150200250400500700

L

1000

1100

650 650 870 87012001200

l

400400400400500500500 450 450 450 550 550 550 550 550315325435 555600 600

e1

12,0

13,2

14,4

e2

7,0 7,8 8,4 9,0 9,610,812,0 7,8 8,4 9,0 9,610,210,812,013,2 7,8 8,4 9,010,812,014,4

PN 10

232,0355,0358,0362,0392,0397,0365,0389,0334,0339,0397,0401,0406,0440,0555,0———479,0—691,0

PN 16

260,0383,0386,0390,0420,0430,0450,0381,0384,0389,0447,0453,0469,0503,0572,0333,0458,0465,0515,0655,0729,0

Weight in kg ≈ Dimensions in mm

DN 1

50* 65* 80

100

125

150

DN 2

40 40 50

40* 50* 65

40* 50* 65* 80

50* 65* 80*100

80* 100*125

L

200200200200200200200200200200200200200200200200200

e1

7,07,0

7,0

7,2

7,5

7,8

e2

7,07,07,07,07,07,07,07,07,07,07,07,07,07,27,07,27,5

PN 10

7,2 8,0 9,7 8,1 8,6 9,5 9,1 9,7—

11,5———

13,6——

17,0

PN 16

7,2 8,0 9,7 8,1 8,6 9,5 9,1 9,710,811,515,013,512,913,615,416,4—

PN 25

7,2 8,0 9,7 8,1 8,610,3 9,1 9,7—

13,5——

19,418,516,216,419,0

PN 40

7,2 8,0 9,7 8,1 8,611,0 9,112,914,014,0——

19,4—

19,523,823,0

Weight in kg ≈Dimensions in mm

Dimensions and weights

Page 52: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

105104

22.2

Double flanged tapers, concentric – FFRDouble flanged tapers, concentric – FFR

DN 1

200

250

300

350

400

450

DN 2

50* 65* 80* 100* 125*

150 80* 100* 125* 150*

200 80* 100* 125* 150* 200*

250 150* 200* 250*

300 200* 250* 300* 350*

400

L

300300300300300300300300300300300300300300300300300300300300300300300300300300

e1

8,4

9,0

9,6

10,2

10,8

11,4

e2

7,07,07,07,27,57,87,07,27,57,88,47,07,27,57,88,49,07,88,49,09,68,49,09,6

10,210,8

PN 10

25,9—

21,023,724,826,527,030,033,535,634,032,037,334,636,740,046,047,051,055,656,054,562,062,674,096,7

PN 16

25,928,021,023,724,826,527,030,033,535,634,032,037,334,636,740,046,0—

69,051,663,265,075,064,875,699,0

PN 25

— —

29,1 27,0 —

36,2 —

48,0 —

41,0 44,0 — 53,0 — —

47,5 88,0 — —

77,0 72,0

86,4 86,0106,5

PN 40

— —

36,1 33,0 —

40,5 — — —

50,2 58,0 — — — —

84,8110,0

——

100,0108,0

136,0130,0146,0

Weight in kg ≈Dimensions in mm

l

DN 1

500

600

700

800

900

1000

1200

DN 2

250* 300* 350*400

300* 350* 400*500

350* 400* 500*600

400* 500* 600*700

500* 600* 700*800

600* 700* 800*9001000

L

600600600600600600600600600600600600600600600600600600600600600600600600790

e1

12,0

13,2

14,4

15,6

16,8

18,0

20,4

e2

9,09,6

10,210,89,6

10,210,812,010,210,812,013,210,812,013,214,412,013,214,415,613,214,415,616,818,0

PN 10

120,0135,0149,6143,0175,0162,0204,7197,0251,6263,0285,0315,0264,5356,4361,3413,0320,0357,0374,0392,0372,0375,0545,0550,0

PN 16

138,3159,3176,0173,0221,0227,0233,0238,0

——

308,0346,0

—389,0416,0447,0398,0410,0390,0432,0

—427,0583,0612,0824,0

PN 25

———

185,0———

249,0———

399,0——

475,0500,0

———

536,0—

540,0704,0

——

PN 40

———

220,0———

321,0—————————————————

Weight in kg ≈Dimensions in mm

Page 53: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

107106

22.2

Double flanged tapers, eccentric – FFReacc. to manufacturer’s standard

Double flanged tapers, eccentric – FFReacc. to manufacturer’s standard

DN 1

50 65

80

100

125

150

DN 2

40 40 50 40 50 65 40 50 65 80 50 65 80 100 50 80 100 100 125

L

200 200 200 200 200 200 200 200 200 200 200 200 200 300 300 300 200 300 300

e1

7,0 7,0

7,0

7,2

7,5

7,8

e2

7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,0 7,2 7,0 7,0 7,2 7,2 7,5

PN 10

——————

11,513,012,513,514,015,016,017,021,020,021,518,426,5

PN 16

——————

11,513,012,513,514,015,016,017,021,020,021,518,426,5

PN 25

——————

12,012,513,013,514,615,516,617,622,024,023,025,526,5

PN 40

7,0 8,5 9,0 9,510,011,012,012,513,013,516,516,817,918,924,026,025,027,530,0

Weight in kg ≈Dimensions in mm

Dimensions and weights

Manufacturing of other dimensions and face-to-face lengths possible.

DN 1

200

250

300

350

400

450500

DN 2

80100125150100125150200100150200250200250250300300150200250300300350250250300350400450

L

300300300300300300300300300300300300500500600300500500600500500600500600500500500500500

e1

8,4

9,0

9,6

10,2

10,8

11,412,0

e2

7,0 7,2 7,5 7,8 7,2 7,5 7,8 8,4 7,2 7,8 8,4 9,0 8,4 9,0 9,0 9,6 9,6 7,8 8,4 9,0 9,6 9,610,2 9,0 9,0 9,610,210,811,4

PN 10

26,0 27,0 32,4 25,4 37,0 42,0 42,0 45,9 42,5 45,0 58,0 55,6 88,0 90,0 98,0102,0108,0 88,0 98,0 92,0113,0115,0125,0113,0124,0123,5130,5172,0166,0

PN 16

26,0 27,0 28,5 29,5 37,0 38,0 39,5 44,0 42,5 48,6 58,0 55,6 91,0 92,5103,0 97,0114,0 97,0 98,0109,0112,0129,0134,0125,0136,0144,0151,0172,0188,0

PN 25

28,0 29,5 30,5 31,5 40,5 41,5 44,5 50,0 47,0 61,5 61,5 69,5105,0108,0114,0108,0125,0109,0117,5130,0132,0141,0153,0135,0149,5162,0168,0204,0

PN 40

34,5 35,5 36,5 38,5 50,5 52,5 53,5 66,0 62,0 84,5 —

97,0128,0135,0141,0135,0162,0145,0157,5170,0191,0200,0208,0182,0195,0213,0217,0172,0

Weight in kg ≈Dimensions in mm

Page 54: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

108 109

22.2

Single flange bellsacc. to manufacturer’s standard

Double flanged tapers, eccentric – FFReacc. to manufacturer’s standard

Weight in kg ≈Dimensions in mm

DN 1

600

700

800

9001000

DN 2

300400500400500600500600700800800

L

500500500600600600600600600600600

e1

13,2

14,4

15,6

16,818,0

e2

19,610,812,010,812,013,212,013,214,415,615,6

PN 10

192,0207,0248,4292,0320,0343,0

—275,0297,0

—429,0

PN 16

203,0252,0264,0

—356,0

—270,0327,0372,0462,0

PN 25

222,0263,0274,0

—————

477,0——

PN 40

298,0356,0369,0

————————

l

DN

40506580

100125150200250300350400450500600700800900

100012001600

ø d

140140155170190210260300350420550550650680780895

10151100120014401880

h

100110115120130145150180200250250250280300300300320390390520550

PN 10

4,05,07,09,0

11,014,017,025,932,044,063,074,0

115,0130,0175,0195,0250,0270,0355,0465,0780,0

Dimensions in mm Weight in kg ≈

Dimensions and weights

Page 55: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

bb

110 111

22.2

Blank flanges – X

* acc. to manufacturer’s standard

Flange connection dimension acc. to EN 1092–2

DN 25 – 250 DN 300 – 1000

DN

25* 32* 40* 50* 65*

80 100 125 150 200 250 275 300 350 400 450 500 600 700 800 9001000120014001600

PN 10

16,016,022,022,022,016,016,016,016,017,019,020,520,520,520,521,522,525,027,530,032,535,040,041,044,0

PN 16

16,016,022,022,022,016,016,016,016,017,019,0—

20,522,524,0—

27,531,034,538,041,545,052,055,060,0

PN 25

16,016,022,022,022,016,016,016,017,019,021,5—

23,526,028,0—

32,537,0———————

PN 40

16,016,022,022,022,016,016,020,523,027,031,5—

35,5————————————

PN 10

1,0 1,8 2,1 2,5 3,0 4,0 4,6 6,0 7,6 11,4 17,2 25,0 25,0 30,5 38,0 67,0 56,0 86,0 127,0 176,0 230,0 334,0582,0

—896,0

PN 16

1,0 1,8 2,1 2,5 3,0 4,0 4,6 6,0 7,6 11,4 16,8

— 24,5 34,5 46,0 91,5 79,0123,0174,0244,0323,0480,0737,0895,0

1221,0

PN 25

1,0 1,8 2,1 2,5 3,0 5,0 5,1 6,6 8,6 13,6 21,0

— 31,0 43,5 59,5

— 96,0147,0

———————

PN 40

1,0 1,8 2,1 2,5 3,0 5,0 5,1 8,2 11,4 20,0 33,0

— 51,0

————————————

Weight in kg ≈ Dimensions in mmb

Dimensions and weights

Page 56: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Maße und Gewichte

112 113

22.2

Blank flanges with threaded bore – XGacc. to manufacturer’s standard

DN

40

50

65

80

100

125

150

175

200

250

300 350 400 450 500 600 700 800 90010001200

PN

10–40

10–40

10–40

10–40

10–40

10–40

10–40

10–40

10–40

10–40

10–40

RP (DIN 2999 )

3/8 – 1 1/22

3/8 – 1 1/22 – 2 1/23/8 – 1 1/22 – 2 1/23/8 – 1 1/2

2 – 3 3/8 – 1 1/2

2 – 4 3/8 – 1 1/2

2 – 43/8 – 1 1/2

2 – 4 3/8 – 1 1/2

2 – 4 3/8 – 1 1/2

2 – 43/8 – 1 1/2

2 – 4

3/8 – 3

PN 10

16,036,016,036,016,036,017,036,019,036,020,520,520,520,522,525,027,530,032,535,040,0

PN 16

16,036,016,036,016,036,017,036,019,036,020,522,522,5—

27,531,034,538,041,545,052,0

PN 25

16,036,017,036,0——

19,036,021,536,023,526,026,0—

32,537,0—————

PN 40

20,536,023,036,0——

27,036,031,536,035,5——————————

Dimensions in mme

Dimensions and weights

22,027,022,027,022,027,016,030,016,036,0

Page 57: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

115114

22.2

Pipe caps with TYTON® or screw-gland socket – Oacc. to manufacturer’s standard

DN 80 – 250 DN 300 – 1200

DN

80 100 125 150 200 250 300 350 400 450 500 600 700 800 900

ø D

146,0 166,0 197,0 224,0 280,0 336,0 391,0 450,0 503,0 541,5 598,0 707,0 824,0 935,01042,0

t 1 84 88 91 94100105110110110120120120150160175

PN 16

34,438,041,5

PN 25

16,016,016,017,019,021,523,526,028,030,032,537,0

PN 16

160220345

PN 25

4,5 4,8 6,0 8,0 12,0 19,0 27,0 34,0 45,0

— 73,0110,0

Weight in kg ≈Dimensions in mm

Dimensions and weights

e

Page 58: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

116 117

22.2

Flanged socket duckfoot bends 90° – ENacc. to DIN 28 650

Conversion flanges DN 80 4 / 8 holesacc. to manufacturer’s standard

DN

80

PN

10 / 40

ø D

200

e

27

3,9

Dimensions in mm Weight in kg ≈

Dimensions and weights

1) without screw ring

DN

80100150

L1

165180220

L2

145158265

c

110125160

d

180200250

e

7,07,27,8

Weight in kg ≈ 1) Dimensions in mmwith

screw-gland socket PN 10 / PN 16

14,618,4

with TYTON® socket

PN 10 / PN 16

15,719,036,5

Dimensions and weights

Page 59: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

119118

22.2

Plugs for screw-gland and TYTON® sockets – Pacc. to manufacturer’s standard

Double socket duckfoot bends 90° with Novo sockets – MMN / MMNRacc. to manufacturer’s standard

DN

80100150200

L1

119128157181

L2

100125150225

c

110125160190

d

180200250300

PN 10

13,617,819,230,5

Dimensions in mm Weight in kg ≈ e

7,07,27,88,4

Dimensions and weights

Also with 1, 2 or 3 draining bores with thread measured in inches available.Also with PE connection.

DN

40 80100125150200250300350400500

L

82 90 98103103108120125125125173

e1

20 22 23 23 23 23 23 25 25 25 25

e2

8,0 9,0 9,5 9,510,011,012,013,014,014,519,8

with screw-gland socket

PN 10 / PN 16

1,0 3,0 4,0 —

7,512,018,025,537,546,580,0

with TYTON® socket

PN 10 / PN 16

— 3,0 4,0 6,0 7,512,018,025,537,546,580,0

Dimensions in mm Weight in kg ≈

Dimensions and weights

Page 60: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

121120

22.2

Screw plugs for screw-gland sockets – PXacc. to manufacturer’s standard

Screw rings for plugsacc. to manufacturer’s standard

Screw rings are needed in conjunction with plugs ( plugs for screw-gland sockets ) to close the pipeline.

DN

40 50 80100125150200250300

e

111112141417202223

L

656772757881869294

PN 10 / PN 16

1,61,82,93,44,45,59,0

13,017,5

Dimensions in mm Weight in kg ≈

Dimensions and weights

DN

40

L

97

ø d

56

Rp ( DIN 2999 )3/4 – 2

PN 10 / PN 16

2,0

Dimensions in mm Weight in kg ≈

Dimensions and weights

Page 61: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

123122

22.3

Ductile cast iron ( GGG ) special fittings

• Single socket pieces with angled branch 45° – C with screw-gland socket – acc. to manufacturer’s standard

• Socket spigot tapers – R with screw-gland socket – acc. to manufacturer’s standard

• Flanged socket bends 90 ° – EQ with screw-gland socket – acc. to manufacturer’s standard

For further information please give us a call or contact your specialist dealer. We look forward to your questions.

Contact: Export Department, Phone: +49 6093 87 560, e-mail: [email protected]

Page 62: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#125124

DN

40506580

100125150200250300350400450500600700800900

1000120014001600

d1

56668298

118144170222274326378429480532635738842945

1048125514621668

D

150165185200220250285340400455505565615670780895

101511151230145516751915

b

16161616161616171920202021222527303235404144

Dimensions

The dimension L is subject to customer specification and is to be measured from the flange sealing seat or from the socket length up to the centre of the puddle flange.

Fittingswith Puddle Flanges

Fittingswith Puddle Flanges

Dimensions in mm 22.3

Flanged fittings:

Socket fittings:

* t = Socket length

Page 63: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

127126

22.4

These fittings for plastic pipelines are made of ductile cast iron (GGG) and they are manufactured acc. to EN 12 842.The flanges of the KS fittings are acc. to EN 1092-2. All KS fittings are delivered with gaskets.

Coatings: see page 47.

Remarks forductile cast iron fittings for plastic pipelines

Page 64: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

129128

22.4

Flanged spigots – F-KSFlanged sockets – E-KS

DN

50 65 80100125150200250300400

A

100 110 120 125 155 150 180 220 235 310

L min

2014131118 82936 636

ø d1

63 75 90110140160 225 280 315450

PN 10

3,0 3,8 5,5 6,0 9,010,018,028,037,572,5

Dimensions in mm Weight in kg ≈

DN

50 65 80100125150200250300400

L

128130135150165170190248264294

EL

100105105120130140162219232261

ø d

63 75 90110140160 225 280 315 450

PN 10

3,2 4,5 5,0 6,5 9,611,016,027,737,255,8

Dimensions in mm Weight in kg ≈

Dimensions and weights Dimensions and weights

Page 65: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

131130

22.4

Double socket tees with flanged branch – MMA-KSFlanged socket duckfoot bends 90 ° – EN-KSacc. to manufacturer’s standard

DN

80 100150

L1

165180220

L2

140150145

c

110125160

ø d1

90110160

PN 10

15,620,536,2

Dimensions in mm Weight in kg ≈ d

180200250

DN 1

50 65

80

100

125

DN 2

50 50 65 50 65 80 50 65 80

100* 50* 65*

80100125

A

250265280285300315310325340360335350365385410

L

63 66 81 69 84 99 74 89104124 80 95110130135

ø d1

63 75 75 90 90 90110110110110140140140140140

h

140150150160160165170175175180185185190195200

PN 10

6,8 7,8 9,4 9,210,411,410,911,915,015,815,917,218,519,5 23,1

Weight in kg ≈ Dimensions in mm

Dimensions and weights

Dimensions and weights

* acc. to manufacturer’s standard

Page 66: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

133132

22.4

l

All socket tees – MMB-KSDouble socket tees with flanged branch – MMA-KS

DN 1

150

200

250

300

400

DN 2

50 65 80100125150

80* 100*

125150

200* 80100150200250 80100150

200* 250* 300* 80*100

200* 400*

A

360375390410435460455475500525575515535585635885550570620670720770660680780980

L

98 98116136161186128148173198248140160210260310152172222272322372200220320520

ø d1

160 160 160 160 160 160225225225225225280280280280280315315315315315315450450450450

h

205210205210215220235240245250260265270280290300295300310320330340355360380420

PN 10

19,2 21,0 20,8 24,2 26,5 29,7 34,9 37,6 39,8 44,7 51,4 48,0 52,0 57,6 65,6 73,6 58,9 61,6 71,1 79,4 89,2 93,0124,7130,5168,1219,0

Weight in kg ≈ Dimensions in mm

* acc. to manufacturer’s standard * ac

c. to

man

ufac

ture

r’s st

anda

rd

DN 1

5065

80

100

125

150

200

DN 2

50 50 65 50 65 80 50 65

80*100 80

100*125 80100

125*150 80100125150200

A

257272283292303216317328341360366385412391410437455456475502520578

L

70 73 84 76 87101 81 92106124112130157118136163181130148175 193 252

ø d1

63 75 75 90 90 90110110110110140140140160160160160225225225225225

l1

35 35 45 50 50 55 60 60 60 65 75 80 80 82 85 90 95115115120120130

PN 10

4,1 5,0 5,4 6,5 7,0 7,3 8,7 9,110,512,512,814,316,015,318,520,422,728,730,732,439,842,7

Weight in kg ≈ Dimensions in mm

h

128,5 134,0 141,5 140,5 148,0 158,0 150,0 157,5 167,7 180,0 181,5 193,5 206,0 190,0 202,5 115,0 227,5 219,0 231,5 244,0 256,5 289,0

ø d2

63 63 75 63 75 90 63 75 90110 90110140 90110140160 90110140160225

Dimensions and weights

Page 67: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

135134

22.4

Double sockets with internal thread branch – MMI-KSDouble socket tapers – MMR-KS

DN

50

65

80

100

Rp*

11 1/41 1/221

1 1/41 1/221

1 1/41 1/221

1 1/41 1/22

A

255255255255270270270270290290290290315315315315

L

68

71

74

79

ø d1

636363637575757590909090110110110110

PN 10

3,64,34,34,55,05,65,65,86,67,27,27,48,49,09,09,2

Dimensions in mm Weight in kg ≈ h

60

65

85

90

Dimensions and weights

DN 1

65 80

100

125

150

200

250

DN 2

50 50 65 65 80 80 100 100 125 125 150 150 200

A

213,0229,5231,5253,5257,0283,0286,0307,5306,5368,0371,5426,5430,0

L

20 28 24 36 31 48 41 53 42 77 71 102 79

ø d1

75 90 90 110 110 140 140 160 160 225 225 280 280

ø d2

63 63 75 75 90 90110110140140160160 225

PN 10

3,6 4,8 5,5 6,8 7,2 8,3 9,2 11,012,120,221,828,832,6

Weight in kg ≈ Dimensions in mm

Dimensions and weights

* Rp acc. to DIN 2999

Page 68: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

137136

22.5

Fittings as per EN 598.

Coating: inside and outside powder epoxy coating red/brown-red colour.Blue colour on request.

Further information see page 47 and 50.

Remarks forDuctile Iron Fittingsfor Sewage Pipelines

l

Double sockets with internal threaded branch – MMI-KS

* Rp acc. to DIN 2999

DN

125

150

200

250300

Rp

11 1/41 1/221

1 1/41 1/221

1 1/41 1/2222

A

340340340340365365365365430430430430490523

L

85

91

103

115127

ø d1

140140140140160160160160225225225225280315

PN 10

10,912,512,512,715,115,715,715,927,027,627,627,841,451,2

Dimensions in mm Weight in kg ≈ h

105

115

155

180195

Page 69: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#139138

22.5

Drilling saddle piece 90° 90° branch with clay pipe socket and NBR sealing

SM 90

Drilling saddle piece 45° 45° branch with clay pipe socket and NBR sealing

SM 45

for cast iron, steel or fibre cement pipes as per EN 598

for cast iron, steel or fibre cement pipes as per EN 598

DN 1

250 – 300350

400 – 600700 – 1200

DN 2

150

suitable for clay pipe spigot end

186

Weight in kg ≈

10,39,89,38,5

Dimensions and weights

ø d3 drilling

172

Dimensions in mm

DN 1

250 – 300350 – 400

DN 2

150

suitable for clay pipe spigot end

186

Weight in kg ≈

11,0

Dimensions and weights

ø d3 drilling

172

Dimensions in mm

Page 70: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#141140

22.5

Drilling saddle piece 90° 90° branch with spigot for ductile iron pipeSI 90

Drilling saddle piece 90° 45° branch with spigot for ductile iron pipeSI 45

DN 1

250 – 300300350400

400 – 600500 – 600700 – 800

700 – 1200900 – 1200

DN 2

150200200200150200200150200

ø d2 Weight in kg ≈

9,115,316,014,17,213,212,66,613,0

Dimensions and weights

ø d3

ductile iron

170222222222170222222170222

clay pipe

186242242242186242242186242

drilling

172232232232172232232172232

Dimensions in mm

DN 1

250 – 300

DN 2

150

ø d2 ductile iron

170

Weight in kg ≈

9,1

Dimensions and weights

ø d3 drilling

172

Dimensions in mm

for cast iron, steel or fibre cement pipes as per EN 598

for cast iron, steel or fibre cement pipes as per EN 598

Page 71: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#143142

22.5

TYTON®-couplings with TYTON® NBR sealsMM

Spigot end branch 67° ICI 67

as per EN 598 suitable for ductile iron sewage pipes

as per EN 598

DN 1

150200250300350400500600700800

DN 1

200

DN 2

150

ø d1

222

ø d2

170

L 1

568

L 2

326

h

310

Weight in kg ≈

26,0

ø d1

170222274326378429532635738842

Weight in kg ≈

8,011,514,721,029,036,058,079,0125,0126,0

Dimensions and weights

Dimensions and weights

ø D

210262315370425480590695810920

L

160165180200215210225250305325

Deviation per socket

Dimensions in mm

Dimensions in mm

Page 72: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#145144

22.5

as per EN 598 with NBR sealing

as per EN 598

DN 1

200

DN 2

150 STZ

ø d2

186

L 1

370

L 2

310

h

400

Deviation per socket

Weight in kg ≈

38,0

Dimensions and weights

Dimensions in mm

Double socket branch with TYTON® sockets 45° branch with spigot for clay pipe MMI 45 or67° branch with spigot for ductile iron pipe MMI 67

Double socket branch with TYTON® sockets 45° branch with clay pipe socketMMM

DN 1

200200

DN 2

150 STZ150 GGG

ø d2

186170

L 1

370360

L 2

310222

h

400310

45°67°

Deviation per socket

5°5°

Weight in kg ≈

34,531,0

Dimensions and weights

Dimensions in mm

Page 73: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#147146

22.5

Pipe sealing capRVD

DN 1

150

ø D in mm

143

Weight in kg ≈

2,0

Dimensions and weights

Manhole connection piece with TYTON® socketSA

as per EN 598

DN 1

1502002503004005006007008009001000

Weight in kg ≈

6,07,59,512,016,019,528,054,057,076,082,0

Dimensions and weights

ø D

260310360415520635730845950

10501160

L

100

110

120

160

175185

Deviation

Dimensions in mm

with ventilation outlet

Page 74: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#149148

22.5

DN

80100125150200250300350400500

L

500500550550650700750800900900

a x b

250 / 80250 / 100300 / 125290 / 150330 / 200360 / 250400 / 300500 / 350480 / 400550 / 500

PN 10

33 41 56 59

90124163232268414

Dimensions in mm Weight in kg ≈

Dimensions and weights

Double flanged hatchboxesacc. to manufacturer’s standard

Double socket hatchboxesacc. to manufacturer’s standard

DN

100150200250300350400500

L

450550600650700750850850

a x b

250 / 100290 / 150330 / 200360 / 250400 / 300500 / 350480 / 400550 / 500

PN 10

40 68 88120159227265385

Dimensions in mm Weight in kg ≈

Dimensions and weights

Page 75: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#151150

22.5

Double socket pieces with 45° socket branch – MMCacc. to manufacturer’s standard

DN 1

80100

125

150

200

250

300

DN 2

80 80100100125 80100150100150200100150200250100150200250300

Lu

270300300350350380380380500500500600500500600700450450700700

lu

200250250250250300300300360380380395400400460430470470500525

z

200250250250250300300300360380380395395430460430430420500525

e1

7,0 7,2

7,5

7,8

8,4

9,0

9,6

Dimensions in mm

e2

7,0 7,0 7,2 7,2 7,5 7,0 7,2 7,8 7,2 7,8 8,4 7,2 7,8 8,4 9,0 7,2 7,8 8,4 9,0 9,6

with TYTON® sockets

22,0 25,0 30,0 40,0 41,0 33,0 36,0 39,0 56,2 62,0 65,0 67,0 71,0101,0120,0 89,6 93,4 95,0128,0142,6

Weight in kg ≈

Dimensions and weights

l

Double socket pieces with 45° socket branch – MMCacc. to manufacturer’s standard

DN 1

350

400

500

600

700

800

DN 2

150200250300350100125150200300400100150200250300400500150200250300400500600200300400500600700600800

Lu

700 700 700 700 880 440 440 440 640 850 850 450 450 740 740 740 850 1040 750 750 750 750 1150 1210 1210 575 925 92510801380138012501550

lu

470 510 530 570 690 480 490 490 570 650 650 590 590 620 640 720 720 845 750 750 775 800 800 920 985 825 885 94010201070114011501275

z

470 510 530 610 760 440 450 450 580 700 650 515 515 550 620 680 750 845 620 620 680 740 765 915 975 675 810 890 9901055114011101275

e1

10,2

10,8

12,0

13,2

14,4

15,6

Dimensions in mm

e2

7,8 8,4 9,0 9,6 10,2 7,2 7,5 7,8 8,4 9,6 10,8 7,2 7,8 8,4 9,0 9,6 10,8 12,0 7,8 8,4 9,0 9,6 10,8 12,0 13,2 8,4 9,6 10,8 12,0 13,2 14,4 13,2 15,6

with TYTON® sockets

153,0 160,0 172,0 177,0 195,0 131,0 138,0 141,0 159,0 181,0 209,0 167,0 177,0 220,0 231,0 237,0 266,0 385,0 240,0 245,0 250,0 260,0 400,0 482,0 506,0 298,0 433,0 445,0 635,0 693,0 750,0 745,01013,0

Weight in kg ≈

Page 76: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#153152

33

Ductile cast iron (GGG) valves

Page 77: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanisedflange connection dimensions: as per EN 1092–2face-to-face length: as per EN 558–1, basic series 15for potable water, sewerage, gas or biogas

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13 (for biogas and sewerage: 1.4571)stem nut: special brass (for biogas and sewerage: aluminium bronze)rubber parts made of high-quality elastomer:sealing wedge for water: EPDMsealing wedge for gas, biogas and sewerage: NBR

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for sewerage)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for sewerage)• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for gas)• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for biogas)

PG 3 5 bar

0,5 a. 6

PG 3 16 bar

0,5 a. 17,6

PG 2

0,5

17,6 11

17,6 11

24 15 24 15 24 24

Test pressure in bar test medium water test medium air body seat seat seat seat

Field of application: potable water up to 60 °C; sewerage; gas as per G 260/I; biogas as per medium analysis

Nominal diameter

DN

40-300

200-300 50-300

200-300 40-300 50-300

Nominal pressure

PN

16 10 16 10

0,5/16 5

Field of

application

potable water potable water

sewerage sewerage

gas biogas

3

155

3.1

154

Gate valves type 4004with flanges PN 10 / 16

DN

40506580

100125150200200250250300300

PN

16161616161616101610161016

FTF

240250265280300325350400400450450500500

ø K

110125145160180210240295295350355400410

h1

207233270270295330 373462462648648723723

ø D

150165185200220250285340340400400455455

a

141417171919192424 27 272727

Weight in kg ≈

12,5 14,7 18,8 17,5 24,6 31,0 40,6 61,5 61,0113,6113,0161,0160,0

Number of

screws

4 4 4 8 8 8 8 8 1212121212

ø L

19191919191923232323282328

Dimensions and weights ( Dimensions in mm )

Page 78: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanised flange connection dimensions: as per EN 1092–2face-to-face length: as per EN 558–1, basic series 14for potable water, sewerage, gas or biogas

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13 (for biogas and sewerage: 1.4571)stem nut: special brass (for biogas and sewerage: aluminium bronze)rubber parts made of high-quality elastomer:sealing wedge for water: EPDMsealing wedge for gas, biogas and sewerage: NBR

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for sewerage)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for sewerage)• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for gas)• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for biogas)

PG 3 5 bar

0,5 a. 6

PG 3 16 bar

0,5 a. 17,6

PG 2

0,5

17,6 11

17,6 11

24 15 24 15 24 24

Test pressure in bar test medium water test medium air body seat seat seat seat

Field of application: potable water up to 60 °C; sewerage; gas as per G 260/I; biogas as per medium analysis

Nominal diameter

DN

40-300

200-300 50-300

200-300 40-300 50-300

Nominal pressure

PN

16 10 16 10

0,5/16 5

Field of

application

potable water potable water

sewerage sewerage

gas biogas

157156

33.1

Gate valves type 2004 (short face-to-face length)with flanges PN 10 / 16

DN

40506580

100125150200200250250300300

PN

16161616161616101610161016

FTF

140150170180190200210230230250250270270

ø K

110125145160180210240295295350355400410

h1

207233270270295330 373462462648648723723

ø D

150165185200220250285340340400400455455

a

141417171919192424 27 272727

Weight in kg ≈

11,2 13,3 17,0 17,8 22,5 27,8 36,0 54,8 54,4104,4104,0146,7146,0

Number of

screws

4 4 4 8 8 8 8 8 1212121212

ø L

19191919191923232323282328

Dimensions and weights ( Dimensions in mm )

Page 79: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanisedconnection: as per DIN 28603 (TYTON® with pre-chamber)face-to-face length: as per EN 558–1, basic series 13for water

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563Stem: chromium steel X20Cr13stem nut: special brassrubber parts made of high-quality elastomer:sealing wedge for water: EPDM

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80-300

Nominal

pressure PN

16

Field of

application

potable water

159158

33.1

DN

80100125150200250300

PN

16161616161616

h1

270295330373462648723

Weight in kg ≈

19 24 30

37,5 57 107 151

Dimensions and weights ( Dimensions in mm )

ETE

114127140140152165178

a

17191919242727

Gate valves type 4004 plug-in socket gate valves with Novo sockets PN 16

Page 80: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearing sealing wedge entirely vulcanisedconnection: as per DIN 28603 (TYTON® with pre-chamber)face-to-face length: as per EN 558–1, basic series 13for water

Operation: • with hand wheel • with stem extension (for underground installation) – connection as per GW 336 • with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 stem: chromium steel X20Cr13 stem nut: special brass rubber parts made of high-quality elastomer: sealing wedge for water: EPDM

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water) • inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)

Gate valves type 4004 Single socket gate valves with Novo sockets and spigot end PN 16

DN

80100125150200250300

PN

16161616161616

ø D

97117143169221274326

h1

270295330373462648723

ø D1

141161188215271324381

Weightin kg ≈ 18,2 22,5 29,3 36,6 56,0109,0120,0

Dimensions and weights ( Dimensions in mm )

L1

235235290290310310310

L

410422485490525535550

a

17191919242727

160

33.1

161

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80-300

Nominal

pressure PN

16

Field of

application

potable water

Page 81: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearing sealing wedge entirely vulcanisedconnection: as per DIN 28601face-to-face length: as per EN 558–1, basic series 13 for water

Operation: • with hand wheel • with stem extension (for underground installation) – connection as per GW 336 • with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13stem nut: special brassrubber parts made of high-quality elastomer:sealing wedge for water: EPDM

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)

163162

33.1

Gate valves type 4004 socket gate valves with screw-gland sockets PN 16

1) without screw ring

DN

40 50 80100125150200

ETE

106108114127140140152

L

240250282303322328352

h1

207233270295330373462

ø D

150165200220250285340

Weight in kg 1)

10,011,818,022,028,036,053,6

Dimensions and weights ( Dimensions in mm )

a

14141719191924

PN

16161616161616

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

40-200

Nominal

pressure PN

16

Field of

application

potable water

Page 82: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

165164

33.1

Gate valves type 2004 (short face-to-face length) flanged socket gate valves with socket and flange PN 16

DN

80100125150200200

PN

161616161016

FTE

150160210240295295

ø K

160180210240295295

h1

270295330373462462

ø D

200220250285340340

a

171919192424

Weight in kg ≈

17,8 23,3 29,0 36,5 56,0 55,7

Number of

screws

8 8 8 8 812

ø L

191919232323

Dimensions and weights ( Dimensions in mm )

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanised connection: screw-gland socket as per DIN 28601 or socket as per DIN 28603 (TYTON®, Novo); flange as per EN 1092-2Face-to-face length: as per EN 558–1, basic series 13/14for water

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13stem nut: special brassrubber parts made of high-quality elastomer:sealing wedge for water: EPDM

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy finish blue RAL 5005 as per GSK guidelines (for water)

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80-200

Nominal

pressure PN

16

Field of

application

potable water

Page 83: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

167166

33.1

Gate valves type 4004 with welding studs PE PN 10/16

DN

80100100125150150200200

PN

1616161616161616

ø d1

90110125140160180200225

Weightin kg ≈

22,730,531,040,555,554,886,785,5

Dimensions and weights ( Dimensions in mm )

L

650 710 760 790 840 890 970 960

h1

270295295330373373462462

ETE

114127127140140140152152

a

1719191919192424

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanised connection: pre-installed PE-HD welding studs as per DVGW VP 600 with connection dimensions as per DIN 8074/8075. Suitable for electro-welding and butt-weldingface-to-face length: as per EN 558–1, basic series 13for potable water, gas or biogas

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13 (for biogas: 1.4571)stem nut: special brass (for biogas: aluminium bronze)rubber parts made of high-quality elastomer:sealing wedge for water: EPDMsealing wedge for gas, biogas and sewerage: NBR

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for gas) • inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for biogas)

Test pressure in bar test medium water test medium air body seat seat PG 3 5 bar or 10 bar 24 17,6

15 11 24 0,5 and 6 24 0,5 and 11 24 0,5 and 6

Field of application: potable water up to 20 °C; gas as per G 260/I; biogas as per medium analysis

Nominal diameter DN

80-200 80-200 80-200 80-200 80-200

Nominal

pressure PN

16 10 5

10 5

SDR

17 11

11/17 11

11/17

Field of

application

potable water potable water

gas gas

biogas

Page 84: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

169168

33.1

Replacement and repair valves type 4004 with rotatable flanges PN 10/16

DN

80100125150200200

PN

161616161016

FTF

280300325350400400

ø K

160180210240295295

h1

270295330373462462

ø D

200220250285340340

a

171919192424

Weight in kg ≈

20,526,033,544,066,065,5

Number of

screws

8 8 8 8 812

ø L

191919232323

Dimensions and weights ( Dimensions in mm )

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protec-tion for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearing sealing wedge entirely vulcanised connection: thrust-resistant rotatable flanges with integrated sealing, connection dimensions as per EN 1092-2face-to-face length: as per EN 558–1, basic series 15for potable water

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13stem nut: special brassrubber parts made of high-quality elastomer:sealing wedge for water: EPDM

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)

Test pressure in bartest medium water

body seat 24 17,6 15 11

Field of application: potable water up to 60 °C

Nominal diameter DN

80-200 200

Nominal

pressure PN

16 10

Field of

application

potable water potable water

Page 85: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#171170

33.1

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protec-tion for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearing sealing wedge entirely vulcanised connection: thrust-resistant rotatable flanges with integrated sealing, connection dimensions as per EN 1092-2face-to-face length: as per EN 558–1, basic series 14for potable water

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336• with electrical actuator (on request)

Materials: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13stem nut: special brassrubber parts made of high-quality elastomer:sealing wedge for water: EPDM

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)

Replacement and repair valves type 2004 with rotatable flanges PN 10/16

DN

80100125150200200

PN

161616161016

FTF

180190200210230230

ø K

160180210240295295

h1

270295330373462462

ø D

200220250285340340

a

171919192424

Weight in kg ≈

19,021,028,036,055,055,0

Number of

screws

8 8 8 8 812

ø L

191919232323

Dimensions and weights ( Dimensions in mm )

Test pressure in bartest medium water

body seat 24 17,6 15 11

Field of application: potable water up to 60 °C

Nominal diameter DN

80-200 200

Nominal

pressure PN

16 10

Field of

application

potable water potable water

Page 86: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

172

33.1

Gate valves type 3004with welding studs for steel pipes PN 16

DN

40 50 80100150200250300

PN

1616161616161616

ø D

48,3 60,3 88,9114,3168,3219,1273,0323,9

Weightin kg ≈

8,4 10,5 11,8 16,5 27,1 43,5 86,5130,0

Dimensions and weights ( Dimensions in mm )

h1

207233270295373462648723

L

386420280300350400450500

S

4,04,55,65,66,37,16,37,1

a

1414171919242727

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanised connection: welding studs as per EN 12627 for steel pipes, welding gap as per DIN 29692 number 1.3.3face-to-face length: as per DIN 3202 S8for gas

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336

Materials: body ductile cast iron EN-GJS-400-18 (JS-1049) as per EN 1563bonnet, sealing wedge ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13studs for welding ST 35.8 / P235GHstem nut and clamping piece: special brass rubber parts made of high-quality elastomer:sealing wedge for gas: NBR

Surface protection:• inside Düker enamel blue• outside polyurethane as per DIN 30677 T 2, tested 15 KV

Nominal

diameter DN

50-300

Test pressure in bar test medium water test medium air body seat PG 3 16 bar 24 0,5 and 17,6

Field of application: gas as per G 260/I

Nominal pressure PN

16

Field of

application

gas

173

Page 87: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

174

33.1

DN

80100150200

h2

818830923951

A

190190180190

L

650710840960

h1

270295373462

Weight in kg 37,041,066,097,0

Dimensions and weights ( Dimensions in mm )

a

17191924

ø D

90110160225

Gate valves type 4004 with blow-off pipes and welding studs for PE PN 4

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; edge protection for bonnet and body, countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanisedThe welding seams are tested as per AD bulletin HF5/3, welding studs are tested as per EN 12266.connection: pre-installed PE-HD welding studs as per DVGW VP 600 with connection dimensions as perDIN 8074/8075. Suitable for electrical welding and butt welding.face-to-face length: as per EN 558–1, basic series 13for gas

Operation: • on request

Materials: body ductile cast iron EN-GJS-400-18 (JS-1049) as per EN 1563welding studs PE 100stem: chromium steel X20Cr13 stem nut and clamping piece: special brass rubber parts made of high-quality elastomer:sealing wedge for gas: NBR

Surface protection:• inside and outside epoxy finish yellow RAL 1023 as per GSK guidelines (for gas)

test medium air

seat PG 3 5 bar

0,5 and 6

Test pressure in bar

Field of application: gas as per G 260/I

Nominal

diameter DN

80-200

Nominal

pressure PN

5

SDR

11/17

test medium water

body

24

Field of

application

gas

175

Page 88: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

80100150200250300

h2

1107112211841140995980

A

180180224224224220

L

660680730780

10501084

h1

270295373462648723

Dimensions and weights ( Dimensions in mm )

a

171919242727

ø D

88,9114,3168,3219,1273,0323,9

Gate valves type 3004 with blow-off pipes and welding studs for steel pipes PN 4

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanisedAll welding seams are tested as per AD bulletin HP5/3, all welding studs are tested as per EN 12266.connection: welding studs as per EN 12627 for steel pipes, welding gap as per DIN 29692 number 1.3.3face-to-face length: as per DIN 3202 S8for gas

Operation: • on request

Materials: body ductile cast iron EN-GJS-400-18 (JS-1049) as per EN 1563bonnet, sealing wedge ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 stem: chromium steel X20Cr13studs for welding ST 35.8 / P235GHsteam nut and clamping piece: special brass rubber parts made of high-quality elastomer:sealing wedge for gas: NBR

Surface protection:• inside Düker enamel blue• outside polyurethane as per DIN 30677 T 2, tested 15 KV

177176

33.1

Weight in kg 28,0 33,0 65,0 82,0120,0138,0

Nominal

diameter DN

80-300

Test pressure in bar test medium water test medium air body seat PG 3 5 bar 24 0,5 and 6

Field of application: gas as per G 260/I

Nominal pressure PN

5

Field of

application

gas

Page 89: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

178

33.1

179

DN

100150150200

h2

1143121612161178

A

180224224224

L

1558177218021880

h1

295373373462

Weight in kg 41,074,082,0120,0

Dimensions and weights ( Dimensions in mm )

a

19191924

ø D

110160180225

Gate valves type 3004 with blow-off pipes and welding studs for PE PN 4

Design features: Resilient-seated gate valve, with smooth passage, internal stem thread, non-rising stem; countersunk and sealed A2 screws between body and bonnet, medium-free stem bearingsealing wedge entirely vulcanisedAll welding seams are tested as per AD bulletin HP5/3, all welding studs are tested as per EN 12266.connection: pre-installed PE-HD welding studs as per DVGW VP 600 with connection dimensions as perDIN 8074/8075. Suitable for electrical welding and butt welding. Double socket welding length. face-to-face length: as per DIN 3202 S8for gas

Operation: • on request

Materials: body ductile cast iron EN-GJS-400-18 (JS-1049) as per EN 1563bonnet, sealing wedge ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563welding studs PE 100stem: chromium steel X20Cr13 steam nut and clamping piece: special brass rubber parts made of high-quality elastomer:sealing wedge for gas: NBR

Surface protection:• inside Düker enamel blue• outside polyurethane as per DIN 30677 T 2, tested 15 KV

test medium air

seat PG 3 5 bar

0,5 and 6

Test pressure in bar

Field of application: gas as per G 260/I

Nominal

diameter DN

100-200

Nominal

pressure PN

5

SDR

11/17

test medium water

body

24

Field of

application

gas

Page 90: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Clapping bands and gasket are identical for TOP and TOPsi.

DN

80 – 300

G

1 1/4 "1 1/2 "2"

h1

151,5151,5151,5

h2

247247247

a

131313

L1

70,573,775,5

Dimensions and weights ( Dimensions in mm )

ConnectionR 1 1/4" – R 2 "

t

212526

Weight in kg ≈

9,08,69,5

181180

33.2

Tapping valves TOP (vertical drilling) PN 16

Design features: Tapping valve for installation on pipes of all nominal diameters between DN 80 and DN 300.Suitable for drilling under pressure. Can be used for pipes made of cast iron, steel and asbestos cement.

Technical features: No additional support valves are required for tapping under pressure. The resilient valve flap integrated into the type TOP closes automatically after the drilling bar is drawn back.

maximum drilling diameter: 38 mmstem square ends: 12 mm

outlets: internal pipe thread as per DIN 2999: Rp 1, Rp 1 1/4, Rp 1 1/2, Rp 2

clapping band types: see page 185

Materials: body ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13bonnet, obturator: special brassvalve flap: rubberised steelrubber parts of high-quality elastomer (EPDM)

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy resin blue RAL 5005 as per GSK guidelines (for water)

Nominal

diameter DN

25-50

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal pressure PN

16

Field of

application

potable water

Page 91: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#183182

33.2

Clapping bands and gasket are identical for TOP and TOPsi.

ConnectionR 1 1/4" – R 1 1/2“

DN

80 – 300

G

1 1/4 "1 1/2 "2"

h1

151,5151,5151,5

h2

247247247

a

131313

L

190190

Dimensions and weights ( Dimensions in mm ) t

2626

Weight in kg ≈

6,46,3

Nominal

diameter DN

25-50

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal pressure PN

16

Field of

application

potable water

Tapping valves TOPsi (horizontal drilling)PN 16

Design features: Tapping valve for installation on pipes of all nominal diameters between DN 80 and DN 300.Suitable for drilling under pressure. Can be used for pipes made of cast iron, steel and asbestos cement.

Technical features: No additional support valves are required for tapping under pressure.

maximum drilling diameter: 38 mmstem square ends: 12 mm

outlets: internal pipe thread as per DIN 2999: Rp 1, Rp 1 1/4, Rp 1 1/2, Rp 2

clapping band types: see page 185

Materials: body ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13bonnet, obturator: special brassrubber parts of high-quality elastomer (EPDM)

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy resin blue RAL 5005 as per GSK guidelines (for water)

Page 92: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

184

33.2

DN

25324050

ø D

32405063

L1

173186210211

Weightin kg ≈

8,89,29,611,5

Dimensions and weights ( Dimensions in mm )

h1

151,5151,5151,5151,5

h2

247247247247

a

13131313

185

Tapping valves TOP with PE-HD connection PN 16

Design features: Tapping valve for installation on pipes of all nominal diameters between DN 80 and DN 300.Suitable for drilling under pressure. Can be used for pipes made of cast iron, steel and asbestos cement.

Technical features: No additional support valves are required for tapping under pressure. The resilient valve flap integrated into the type TOP closes automatically after the drilling bar is drawn back.

maximum drilling diameter: 38 mmstem square ends: 12 mm

outlets: pre-installed PE-HD connections as per DVGW VP 600 Du 32, Du 40, Du 50, Du 63

clamping band types: see page 169

Materials: body ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563welding studs: PE 100 SDR 11stem: chromium steel X20Cr13 bonnet, obturator: special brass valve flap: rubberised steelrubber parts of high-quality elastomer (EPDM)

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III (for water)• inside and outside epoxy resin blue RAL 5005 as per GSK guidelines (for water)

Nominal

diameter DN

25-50

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 20 °C

Nominal pressure PN

16

Field of

application

potable water

Page 93: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

186 187

33.2

Clapping bands for tapping clamps type 88 and tapping valves TOP and TOPsi

DN

80100125150200250300

a pipe outside

Ø

98118144170222274326

b pipe outside

Ø

106126154180232286338

c pipe outside

Ø

88,9114,3139,7168,3219,1273,0323,9

d pipe outside

Ø

—108

—159———

e pipe outside

Ø

series aseries aseries bseries bseries bseries b

352

Dimensions ( Dimensions in mm )

Design features: flat clapping band for the nominal diameters DN 80 up to 300 and for pipes made of cast iron, cast iron with cement coating, steel or asbestos cement PN 12.5 The clapping bands are packed as a unit with all necessary accessories and marked for the pipe type and diameter.

Materials: flat band with welded-on threaded bolt: stainless steel 1.4301, passivated and plastic-coated washers: stainless steel 1.4104hexagonal nuts: stainless steel 1.4571 with slide coatingthread protectors: plasticsaddle gaskets: EPDM, KTW, W 270

Types: a = for cast iron pipes (bitumen / PE-coated)b = for cast iron pipes (cement-coated)c = steel pipes as per DIN 2448, series 1d = steel pipes as per DIN 2448, series 3e = asbestos cement pipes PN 12.5 as per DIN 19 800

187

Tapping clamp type 88 PN 10/16

DN

80 - 300

Weight in kg ≈ outlet ø d

1" / 1 1/4 " 1 1/2 " / 2"

3 3

Dimensions

* also available as blind clamp

Design features:Tapping clamp type 88 with internal pipe thread as per DIN 2999 for vertical or horizontal drilling

suitable for installation on pipes of all nominal dimensions between DN 80 and DN 300; can be used on pipes of cast iron, steel and asbestos cement. for water

Materials:Tapping clamp: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563

Surface protection:• inside and outside epoxy resin black RAL 9005 as per GSK guidelines

Test pressure in bar test medium water

body

21

Field of application: potable water up to 60 °C

Nominal pressure PN

16

Field of

application

potable water

Nominal

diameter DN

40 - 50 1"– 2"

Page 94: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

25324050

L

105120130150

h1

132,5151,5151,5178,5

SW

46556070

G

R 1R 1 1/4

R 1 1/2

R 2

T

20242732

a

13131313

Dimensions and weights ( Dimensions in mm )

Weight in kg≈

2,63,84,56,0

188 189

33.2

Service connection valves type 1004 with internal pipe thread PN 16

Design features: Resilient-seated gate valve, with smooth passage, interior stem thread, non-rising stemobturator entirely vulcanisedconnection dimensions: as per DIN 2999-1stem square ends: 12 mmface-to-face length: as per DIN 3202 part 4, basic series M 4for potable water or gas

outlets: internal pipe thread as per DIN 2999: Rp 1, Rp 11/4, Rp 11/2, Rp 2

Operation: • with hand wheel• with stem extension set (for underground installation) – connection as per GW 336

Materials: body: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13 bonnet, obturator: special brassrubber parts of high-quality elastomer:obturator for water: EPDMobturator for gas: NBR

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil

class III (for water)• inside and outside epoxy resin blue RAL 5005 as per GSK guidelines (for water,

on request)• inside and outside epoxy resin yellow RAL 1023 as per GSK guidelines (for gas)

Test pressure in bar test medium water test medium air body seat seat PG 3 5 bar 24 17,6

24 0,5 and 6

Field of application: potable water up to 60 °; gas as per G 260/I

Nominal diameter DN

25-50 25-50

Nominal

pressure PN

16 5

Field of

application

potable water

gas

Page 95: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

191190

33.2

DN

25324050

L

345371418421

h1

132,5151,5151,5178,5

Weight in kg ≈

3,36,06,28,3

ø D

32405063

a

13131313

L2 min.

102110124140

Dimensions and weights ( Dimensions in mm )

Service connection valves type 1004 with welding studs PE PN 16

Design features: Resilient-seated gate valve, with smooth passage, interior stem thread, non-rising stem obturator entirely vulcanised connection: pre-installed transition pieces as per DVGW VP 600 Du 32, Du 40, Du 50, Du 63 with connection dimensions as per DIN 8074/75. Suitable for electric welding and butt welding. stem square ends: 12 mmface-to-face length: as per DIN 3202 part 4, basic series M 4for potable water or gas

Operation: • with hand wheel• with stem extension set (for underground installation) – connection as per GW 336

Materials: body: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 welding studs: PE 100 SDR 11 stem: chromium steel X20Cr13 bonnet, obturator: special brass rubber parts of high-quality elastomer: obturator for water: EPDM obturator for gas: NBR

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water) • inside and outside epoxy resin blue RAL 5005 as per GSK guidelines

(for water, on request) • inside and outside epoxy resin yellow RAL 1023 as per GSK guidelines (for gas)

Test pressure in bar test medium water test medium air body seat seat PG 3

5 bar

24 17,6 24 0,5 and 6

Field of application: potable water up to 20°; gas as per G 260/I

Nominal diameter DN

25-50 25-50

Nominal

pressure PN

16 5

SDR

11 11

Field of

application

potable water gas

Page 96: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

4050

L

280286

h1

151,5178,5

K

110125

FT

70,475,4

ø D1

150165

a

1313

Weight in kg ≈

7,3 9,5

Number of screws

44

L2

1919

ø D

5063

Dimensions and weights ( Dimensions in mm )

193192

33.2

Service connection valves type 1004 with flange and welding studs PE PN 16

Design features: Resilient-seated gate valve, with smooth passage, interior stem thread, non-rising stem obturator entirely vulcanisedconnection: pre-installed transition piece as per DVGW VP 600Du 32, Du 40, Du 50, Du 63 flange connection as per EN 1092-2stem square ends: 12 mmface-to-face length: as per DIN 3202 part 4, basic series M 4for potable water or gas

Operation: • with hand wheel• with stem extension set (for underground installation) – connection as per GW 336

Materials: body: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 welding studs: PE 100 SDR 11 stem: chromium steel X20Cr13 bonnet, obturator: special brass rubber parts of high-quality elastomer: obturator for water: EPDM obturator for gas: NBR

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)• inside and outside epoxy resin blue RAL 5005 as per GSK guidelines

(for water, on request)• inside and outside epoxy resin yellow RAL 1023 as per GSK guidelines (for gas)

Test pressure in bar test medium water test medium air body seat seat PG 3

5 bar

24 17,6 24 0,5 and 6

Field of application: potable water up to 20°; gas as per G 260/I

Nominal diameter DN

25-50 25-50

Nominal

pressure PN

16 5

SDR

11 11

Field of

application

potable water gas

Page 97: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

195194

33.2

DN

4050

L

300

SW1

95

a

13

SW2

70

h1

178,5

G2

2"

Weight in kg ≈

7,4

t

32

l1

210

ø D

63

Dimensions and weights ( Dimensions in mm )

Service connection valves type 1004 with internal pipe thread and welding studs PE PN 16

Design features: Resilient-seated gate valve, with smooth passage, interior stem thread, non-rising stemobturator entirely vulcanisedconnection: pre-installed transition piece as per DVGW VP 600 Du 32, Du 40, Du 50, Du 63 internal pipe thread as per DIN 2999-1stem square ends: 12 mmface-to-face length: as per DIN 3202 part 4, basic series M 4for potable water or gas

Operation: • with hand wheel• with stem extension set (for underground installation) – connection as per GW 336

Materials: body: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 welding studs: PE 100 SDR 11 stem: chromium steel X20Cr13 bonnet, obturator: special brass rubber parts of high-quality elastomer: obturator for water: EPDM obturator for gas: NBR

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)• inside and outside epoxy resin yellow RAL 1023 as per GSK guidelines (for gas)

Test pressure in bar test medium water test medium air body seat seat PG 3

5 bar

24 17,6 24 0,5 and 6

Field of application: potable water up to 20°; gas as per G 260/I

Nominal diameter DN

25-50 25-50

Nominal

pressure PN

16 5

SDR

11 11

Field of

application

potable water gas

Page 98: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

197196

33.2

Gate valve combinations Multi I with Novo sockets PN 10 / 16

DN 50PN16

GJS-500-7PE-HD63

EL

Design features: Collar with Novo sockets with lateral outlet combined with gate valve type 1004 DN 50, resilient-seated, with smooth passage, interior stem thread, non-rising stemobturator entirely vulcanisedconnection: pre-installed transition piece as per DVGW VP 600with connection dimensions as per DIN 8074/75. Suitable for electric welding and butt welding. in graduated diameters of 63, 50 and 40 mmstem square ends: 12 mm face-to-face length of the gate valve: as per DIN 3202 part 4, basic series M 4for potable water

Operation: • with hand wheel• with stem extension set (for underground installation) – connection as per GW 336

Materials: body: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563welding studs: PE 100 SDR 11stem: chromium steel X20Cr13 bonnet, obturator: special brassrubber parts of high-quality elastomer:obturator for water: EPDM

Surface protection:• inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 20°

Nominal diameter DN

25-50

Nominal

pressure PN

16

SDR

11

Field of

application

potable water

DN

100125150200250300

L1

568581594620647673

L2

482495508534561587

Weightin kg ≈

212428364558

Dimensions and weights ( Dimensions in mm )

L3

382395408434461487

L4

192205218244271297

Lu

160165165170175180

t1

123126129138143152

Page 99: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

80

Pipe covering mm

800100012501500

H mm

575750

10001250

Dimensions and weights ( Dimensions in mm )

Weight in kg ≈

24,527,531,536,5

199198

33.3

Underground hydrants type 304 PN 16, adjustable height, based on EN 1074-6

Design features: One-part, fully enamelled body with automatic drainage and protection against pressurised water, outlet cover with chain, integrated flange sealing, secured obturator linkage, CE marking as per EN 14339 single shut-off connection: connection flange DN 80 as per EN 1092-2

Technical features: The obturator is shaped flow-optimised and covered on all sides by a firmly vulcanised high-quality elastomer. Automatic drainage and protection against pressurised water are ensured securely due to the construction of the hydrant. The valve stem’s maintenance-free bearing is guaranteed due to the use of two O-rings and an insulating ring. The rolled valve stem ensures high wear resistance.Safety during an exchange of the linkage is guaranteed by a mechanical linkage safety device.The pipe covering is visible from above thanks to cast-on markings on the body.

Materials: body, bonnet, DIN outlet coupling, outlet cover: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13obturator linkage, bolts: stainless steelstem nut and bonnet nut: special brassO-rings made of high-quality elastomerobturator: ductile cast iron with PU elastomer

Surface protection: inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III

Maximum allowable operating pressure

bar16

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80

Nominal

pressure PN

16

Field of

application

potable water

Page 100: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#201200

33.3

DN

80

Pipe covering mm

800100012501500

H mm

575750

10001250

Dimensions and weights ( Dimensions in mm )

Weight in kg ≈

25,028,032,037,0

Underground hydrants type 305 PN 16, adjustable height, based on EN 1074-6

Design features: One-part, fully enamelled body with automatic drainage and protection against pressurised water, outlet cover with chain, integrated flange sealing, secured obturator linkage, CE marking as per EN 14339 double shut-off connection: connection flange DN 80 as per EN 1092-2

Technical features: The obturator is shaped flow-optimised and covered on all sides by a firmly vulcanised high-quality elastomer. Automatic drainage and protection against pressurised water are ensured securely due to the construction of the hydrant. The valve stem’s maintenance-free bearing is guaranteed due to the use of two O-rings and an insulating ring. The rolled valve stem ensures high wear resistance.Safety during an exchange of the linkage is guaranteed by a mechanical linkage safety device.The pipe covering is visible from above thanks to cast-on markings on the body.

Materials: body, bonnet, DIN outlet coupling, outlet cover: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13obturator linkage, bolts: stainless steelstem nut and bonnet nut: special brassO-rings made of high-quality elastomerobturator: ductile cast iron with PU elastomersealing ball: steel with EPDM cover

Surface protection: inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III

Maximum allowable operating pressure

bar16

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80

Nominal

pressure PN

16

Field of

application

potable water

Page 101: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Underground hydrants type 304 S PN 16, adjustable height, based on EN 1074-6

DN

80

Pipe covering mm

750100012501500

H mm

670890

11401390

Dimensions and weights ( Dimensions in mm )

Weight in kg ≈

29333843

203202

33.3

Design features: One-part, fully enamelled body with automatic drainage and protection against pressurised water, outlet cover with chain, integrated flange sealing, secured obturator linkage,CE marking as per EN 14339Type 304 S, design A: single shut-offconnection: connection flange DN 80 as per EN 1092-2

Technical features: The obturator is shaped flow-optimised and covered on all sides by a firmly vulcanised high-quality elastomer. Automatic drainage and protection against pressurised water are ensured securely due to the construction of the hydrant. The valve stem’s maintenance-free bearing is guaranteed due to the use of two O-rings and an insulating ring. The rolled valve stem ensures high wear resistance.Safety during an exchange of the linkage is guaranteed by a mechanical linkage safety device.The pipe covering is visible from above thanks to cast-on markings on the body.

Materials: body, bonnet, DIN outlet coupling, outlet cover: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563stem: chromium steel X20Cr13obturator linkage, bolts: stainless steelstem nut and bonnet nut: special brassO-rings made of high-quality elastomerobturator: ductile cast iron with PU elastomer

Surface protection: inside and outside Düker etec enamel as per DIN 51178, DEV guideline for soil class III

Maximum allowable operating pressure

bar16

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80

Nominal

pressure PN

16

Field of

application

potable water

Page 102: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

8080

100100

Pipe covering mm

1250150012501500

L2

1050105010501050

L1

2190244021902440

L3

680680680680

L4

——355355

e

——200200

L5

55555555

Dimensions and weights ( Dimensions in mm )

Weight / kg≈

136147140151

204 205

33.3

Design features: Pillar hydrant with additional shut-off, automatic drainage and protection against pressurised water, safety lock of the internal mountings, traffic-area version with installation-friendly pre-determined breaking point, Pillar hydrant with additional shut-off, automatic drainage and protection against pressurised water, safety lock of the internal mountings, traffic-area version with installation-friendly pre-determined breaking point,connection: connection flange as per EN 1092-2

Technical features: maintenance-free bearing of the stem extension

Materials: bottom, upper and lower part of the pillar, and bonnet nut: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563operating cap, outlets and outlet covers: aluminiumstem: chromium steel X20Cr13linkage, pin, drainage plate, bolts: stainless steelstem nut, stem bearing, predetermined breaking coupling and bonnet nut: special brassseat ring: rubberized brass O-rings made of high-quality elastomerobturator: entirely vulcanized with high-quality elastomer (EPDM)

Surface protection: • inside Düker enamel• bottom and lower part of the pillar outside: base coat enamel with epoxy resin cover coat

signal red RAL 3001• upper part of the pillar outside: base coat enamel, cover coat 2-components PU paint

signal red RAL 3001• on request: upper part of the pillar inside Düker etec enamel blue, outside Düker enamel red

Pillar hydrants Type 494, design AUD PN 16, adjustable height, based on EN 1074-6

Maximum allowable operating pressure

bar16

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

80-100

Nominal

pressure PN

16

Field of

application

potable water

Page 103: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

DN

100100

Pipe covering mm

12501500

L2

12501250

L1

23902640

L3

950950

L4

355355

ø d

400400

L5

5555

e

200200

Dimensions and weights ( Dimensions in mm )

Weight in kg ≈

185185

207206

33.3

Pillar hydrants type 495, design AFUD PN 16, adjustable height, based on EN 1074-6

Design features: Pillar hydrant with additional shut-off, automatic drainage and protection against pressurised water, safety lock of the internal mountings, traffic-area version with installation-friendly pre-determi-ned breaking point, 2 upper valve outlets B below the protective cover, 1 lower valve outlet ACE marking as per EN 14339connection: connection flange as per EN 1092-2

Technical features: maintenance-free bearing of the stem extension

Materials: bottom, upper and lower part of the pillar, valve head and hand wheel: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563outlets and outlet covers: aluminiumprotective cover: steel X5CrNi18-10stem: chromium steel X20Cr13linkage, pin, drainage plate, bolts: stainless steelstem nut, stem bearing, predetermined breaking coupling and bonnet nut: special brassseat ring: rubberized brass O-rings made of high-quality elastomerobturator: entirely vulcanized with high-quality elastomer (EPDM)

Surface protection: • inside Düker enamel• bottom and lower part of the pillar outside: base coat enamel with epoxy resin

cover coat signal red RAL 3001• upper part of the pillar outside: base coat enamel, cover coat 2-components

PU paint signal red RAL 3001

Maximum allowable operating pressure

bar16

Test pressure in bartest medium water

body seat 24 17,6

Field of application: potable water up to 60 °C

Nominal diameter DN

100

Nominal

pressure PN

16

Field of

application

potable water

Page 104: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

208 209

Butterfly valves type 451 and 4510 with flanges PN 10/16/25

DN 800 up to 1200 in PN 25 only for operating pressure up to 20 bar

Design features: Resilient-seated butterfly valve with slidercrank gear box flow-optimised, completely enamelled valve disc with double eccentric journal square plug connection between valve disc and shaft easily replaceable profile sealing mechanical position indication open/closed on the gear box cover driving shaft and bearing journal chambered medium-free flange connection dimensions: as per EN 1092–2 face-to-face length: as per EN 558–1, basic series 14 for potable water or gas

Operation: • with hand wheel • with stem extension (for underground installation) – connection as per GW 336 • with electrical actuator (on request) • with pivot drive • with pneumatic drive • with hydraulic drive • with end switch unit

Materials: body, valve disc, retaining ring: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563 retaining ring from DN 700 up: stainless steel 1.4301 profile sealing for water: EPDM profile sealing for gas: NBR driving shaft: chromium steel X20Cr13 bearing bushes: red brass Rg 7

Surface protection: • DN 100 up to 600 inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)• from DN 700 up inside Düker enamel, outside 2-components epoxy resin blue RAL 5005 (for water) • inside Düker enamel, outside PUR on request (for water)• inside Düker enamel, outside two-components paint yellow RAL 1023 (for gas)

33.4

Nominal diameter DN

100 – 1200100 – 1200100 – 1200100 – 1200100 – 1200

Field of application

potable waterpotable waterpotable water

gasgas

Nominal pressure PN

1016251016

Allowable operating pressure

bar

1016251016

test medium air

seat PG 3

———

0,5 and 11 0,5 and 17,6

test medium water

body seat

15 11 24 17,6 37,5 27,5 15 11 24 17,6

Field of application: potable water up to 60 °CTest pressure in bar

Page 105: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

210 211

33.4

l➜

Butterfly valves type 451 and 4510 with flanges PN 10 / 16 / 25

Butterfly valves type 4510

Butterfly valves type 451

DN

100100125125150150200200200250250250300300300350350350400400400500500600600600

PN

10/16 25

10/1625

10/162510 16251016 25 1016 25 1016 25 1016 25 1016 1016 25

L

190190200200210210230230230250250250270270270290290290310310310350350390390390

Gear box SKI BI BI BI BI BI BII BII BII BII BII BII BII BII BII BII BII BII BII BI I II I II I II I II I IIV

IV GZ

D

220 235 250 270 285 300 340 340 360 400 400 425 455 455 485 505 520 555 565 580 620 670 715 780 840 845

B

120120130130150150160160160180180180200200200225225225300300300350350330330400

h1

116121131141149157177177187208208220233233248259269287294294319350372401431431

h2

289289325325325325325325325325325325325325325325325325325375375375375390390745

t1

110110122122138138175175175212212212221221221287287287307307307377377440440440

t2

204204216216232232257257257294294294317317317372372372392470470470470560619639

t3

267267279279295295320320320357357357380380380435435435455455455561561651651651

x1

65656565656565656565656565656565656565

100100100100100100100

d1

200200250250250250250250250250250250250250250250250250250315315315315315500500

Dimensions and weights ( Dimensions in mm )

Weight kg3334383944445656617574829397105117123145150192216246276348502533

DN

700700700 8008009009001000100012001200

PN

1016 25 1016 1016 1016 1016

FTF

430430430 470470510510550550630630

Gear box SKIV

IV GZIV GZ IV GZIV GZIV GZ

GS 200 GZIV GZ

GS 250 GZGS 250 GZGS 250 GZ

D

895 910 960 10151025111511251230125514551485

B

400400450 450450550550600600700700

h1

450460485 510515560568620630730750

h2

570745745 745745745675745715715715

t1

549549549 594594634634699699828828

t2

665665665 710710750740815805903903

t3

833833833 873873926808

1009973

10921092

x1

150150150 150150150200150255255255

d1

500400400 400400400400400640640640

Weight kg

650665750 902917120012631490166020702140

Dimensions and weights ( Dimensions in mm )

Page 106: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#213212

33.4

Butterfly valves type 451 and 4510 with flanges PN 10/16/25 Long face-to-face length, with or without bypass

Nominal diameter DN

100 – 1000100 – 1000

Field of application

potable waterpotable water

Nominal pressure PN

1016

Allowable operating pressure

bar

1016

Test pressure in bar

test medium water body seat

15 11 24 17,6

Field of application: potable water up to 60 °C

Design features: Resilient-seated butterfly valve with slidercrank gear box flow-optimised, completely enamelled valve disc with double eccentric journal square plug connection between valve disc and shafteasily replaceable profile sealingmechanical position indication open/closed on the gear box coverdriving shaft and bearing journal chambered medium-freeflange connection dimensions: as per EN 1092–2face-to-face length: as per EN 558–1, basic series 15with bypass (without bypass on request)bypass approx. 1/10 of the main diameterfor potable water

Operation: • with stem extension – connection as per GW 336

Materials: body, valve disc, retaining ring: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563retaining ring from DN 700 up: stainless steel 1.4301 profile sealing for water: EPDM driving shaft: chromium steel X20Cr13 bearing bushes: red brass Rg 7

Surface protection: • DN 100 up to 600 inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)• from DN 700 up inside Düker enamel, outside 2-components epoxy resin blue RAL 5005 (for water)

Page 107: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#215214

33.4

l

Butterfly valves type 451 and 4510 with flanges PN 10/16/25 Long face-to-face length, with or without bypass

Klappenscheibe Typ 451

Klappenscheibe Typ 4510

Klappenscheibe Typ 451

Klappenscheibe Typ 4510

Butterfly valve type 4510

Butterfly valve type 451

DN 900 PN 10/16 on request

DN

300300400400500500600600

DN

70070080080010001000

PN

10 161016101610 16

PN

10 1610161016

L

500500600600700700800800

L

900900

1000100012001200

Gear box SKII BII BII BIII

III / GS 125 GZIII

III / GS 160 GZIV

Gear box SKIVIV

IV GZIV GZIV GZIV GZ

D

455455565580670715780840

D

8959101015102512301255

B

200200300300350350330330

B

400400450450600600

h1

233233294294350372401431

h1

450460510515620630

h2

223223223223278278278278

h2

403608608608608608

t1

480480559559568568637637

t1

745745840840965965

t2

405405485485505505554554

t2

650650730730845845

t3

380380485455561561651651

t3

833833872872

10091009

DN bypass

4040404050505050

DN bypass

80808080

100100

Dimensions and weights ( Dimensions in mm )

Dimensions and weights ( Dimensions in mm )

Weight kg150150218259333366462635

Weight kg680680

1085108520602060

Page 108: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Butterfly valves type 4510 with Novo sockets PN 10/16/25

Design features: Resilient-seated butterfly valve with slidercrank gear boxflow-optimised, completely enamelled valve disc with double eccentric journal square plug connection between valve disc and shaft easily replaceable profile sealingmechanical position indication open/closed on the gear box cover driving shaft and bearing journal chambered medium-freeconnection: plug-in sockets as per DIN 28603 TYTON® with pre-chamberface-to-face length: as per EN 558–1, basic series 14for potable water

Operation: • with hand wheel• with stem extension (for underground installation) – connection as per GW 336 • with electrical actuator (on request) • with pivot drive • with pneumatic drive • with hydraulic drive • with end switch unit

Materials:

body, valve disc, retaining ring: ductile cast iron EN-GJS-500-7 (JS-1050) as per EN 1563profile sealing for water: EPDM driving shaft: chromium steel X20Cr13 bearing bushes: red brass Rg 7

Surface protection: • inside and outside Düker etec enamel as per DIN 51178, DEV guideline for

soil class III (for water)

Nominal diameter DN

150 – 500150 – 500150 – 500

Field of application

potable waterpotable waterpotable water

Nominal pressure PN

101625

Allowable operating pressure

bar

101625

Test pressure in bar

test medium water body seat

15 11 24 17,6 37,5 27,5

Field of application: potable water up to 60 °C

217216

33.4

DN

150150200200250250300300400400500500

PN

10/1625

10/1625

10/1625

10/1625

10/1625

10/1625

L

398398428428453453484484480480543543

Gear box SKI BI BII BII BII BII BII BII BI I II I II I II I I

D

216216271271326326383383491491600600

B

110110120120140140180180220220240240

h1

111111139139166166196196261261305305

h2

223223223223223223223223278278278278

t4

129129138138143143152152149149168168

t1

138138175175212212221221307307377377

t2

232232257257294294317317420420470470

t3

295295320320357357380380446446561561

x1

6565656565656565

100100100100

d

202020202020202020202020

Dimensions and weights ( Dimensions in mm )

Weight kg424257577575

106106187187257257

ETE

145145156156170170183183181181213213

Page 109: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

219218

33.5

Novo plug-in system

On the following pages you will find items which are particularly suited for use in the Novo plug-in system.

Further items can be found here:

Gate valves type 4004 with Novo sockets page 158-159

Gate valves type 4004 with Novo socket and spigot end page 160-161

Butterfly valves type 4510 with Novo sockets page 216-217

Underground hydrants type 304 S design A page 202-203

Flanged socket duckfoot bends 90° with Novo sockets page 118MMN/MMNR

Single socket tees with spigot and socket branch page 84B

Page 110: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

221220

33.5

Collars with Novo sockets – Uacc. to manufacturer’s standardPN 10/16

DN

80100125150

DN

80 80 80100125150

Lu

160160165165

Lu

150200300400400400

ø d

109130156183

e

7,0 7,2 7,5 7,8

e

7,0 7,0 7,0 7,2 7,8 8,4

Weight

in kg ≈

10,013,515,522,5

Weight

in kg ≈

5,07,08,010,519,529,5

Dimensions and weights

Dimensions and weights

Dimensions in mm

Dimensions in mm

Pipe sections with Novo socket – Macc. to manufacturer’s standardPN 10/16

Suitable as hydrant extension

Surface protection: • inside Düker enamel as per DIN 51178 • outside bituminous coating

Special version on request: Novo socket and screw-gland socket

Surface protection: • inside Düker enamel as per DIN 51178 • outside bituminous coating

Page 111: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

223222

33.5

All spigot teesacc. to manufacturer’s standardwith one socket – MI, with spigots – IT PN 10/16

DN 1

80

100

125

DN 2

40 50 80 40 50 80100 40 50 80100125

L1

540

550

600

L2

270

275

300

e1

7,0

7,2

7,5

e2

7,07,07,07,07,07,07,27,07,07,07,27,5

12,012,513,012,013,014,515,017,019,020,021,024,0

Weight in kg ≈

Dimensions in mm

DN 1

80

100

125

DN 2

80

80100

80100125

L1

455

460

510

L2

270

275

300

e1

7,0

7,2

7,5

e2

7,0

7,07,2

7,07,27,5

14,0

16,817,0

22,523,526,5

Weight in kg ≈

Dimensions in mm

All spigot end tee Single socket tee

Dimensions and weights

for gate valves with socket connectionMI with Novo or TYTON® socket

Surface protection: • inside Düker enamel as per DIN 51178 • outside bituminous coating

l

DN 1

150

200

250*

300*

DN 2

40 50 80100125150 80100125150200 80100150200250 80100150200300

l1

620

650

870

870

l2

310

325

435

435

e1

7,8

8,4

9,0

9,6

e2

7,07,07,07,27,57,87,07,27,88,49,07,07,27,88,49,07,07,27,88,49,6

21,522,523,024,525,026,734,035,036,036,538,545,047,048,551,555,064,568,070,072,077,0

Weight in kg ≈

Dimensions in mm

DN 1

150

200

250

300

DN 2

80100125150

80 100 125 150 200 100 150 200 250

80 100 150 200 300

l1

525

550

705

760

l2

310

325

405

435

e1

7,8

8,4

9,0

9,6

e2

7,07,27,57,8

7,07,27,57,88,47,27,88,49,0

7,07,27,88,49,6

27,028,029,030,0

37,0 38,0 39,0 40,0 43,0 60,0 62,0 65,5 66,0

77,0 82,0 86,0 84,0103,0

Weight in kg ≈

Dimensions in mm

Dimensions and weights

All spigot end tee Single socket tee

* acc. to manufacturer’s standard material: ductile iron GGG 50, inside enamel material: ductile iron GGG 50, inside enamel socket NOVO-SIT® as per manufacturer‘s standard

Page 112: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

225224

33.5

Smooth pipe sections with spigot ends – Sas per EN 545PN 10/16

PE adapter pieces for Novo socketsacc. to manufacturer’s standardPN 10/16

for gate valves with socket connection

Surface protection: • inside Düker enamel as per DIN 51178 • outside bituminous coating

Thrust resisting adapter piece for fittings, gate valves and butterfly valves for plug-in sockets NOVO-SIT® PE adapter piece with pre-installed support sleeve and circumferential retaining ringfor retaining the locking segments; PE spigot end for all usual welding procedures, SDR 11for water, transition from ductile cast iron to PE

Materials: • fitting: PE 100 black • support sleeve and retaining ring: stainless steel

DN

80100150200

DN

80100100125150150200200

L

800800800800

L

290315340355360380410426

ø d

98118170222

ø d

90110125140160180200225

e

7,0 7,2 7,5 7,8

e

8,2 10,011,212,814,616,418,220,5

Weight

in kg ≈

12,015,020,030,0

Weight

in kg ≈

1,32,252,63,34,05,57,07,8

Dimensions and weights

Dimensions and weights

Dimensions in mm

Dimensions in mm

Page 113: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Fig. 125 with flange connection PN 10 / 16

227226

33.6

DN

50 65 80100125150200250300350400

Face-to-face dimension

L ≈

210210210250250280300350360390390

Weight in

kg ≈

5,5 7,6 9,4 13,0 16,0 22,0 35,0 60,0 70,0 92,0117,0

Dimensions and weights

Flap valves figure 125 PN 10/16

Design features: Flange connection dimensions: as per EN 1092–2for potable water

Materials: body and bonnet: ductile cast iron EN-GJS-500-7 (JS-1050)as per EN 1563flap shaft: brassflap sealing: elastomer

Surface protection: • inside and outside epoxy resin black RAL 9005 as per GSK guidelines (for water)

Field of application: potable water up to 60 °C

Nominal diameter DN

200-400 50-400

Nominal pressure

PN

10 16

Field of

application

potable water potable water

Page 114: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

229228

44

Accessories

Back to summary

Page 115: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

231230

4

Laying tool V 300 Dfor pressure pipes, fittings and gate valves with TYTON® sockets

DN

80100125150200250300400

Lever length

mm

10501050105010501050105010501050

Weight in kg ≈

16,517,017,518,521,023,524,526,0

Dimensions and weights

Page 116: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Operating keys for valvesas per DIN 3223 A,B,C,E

233232

4DIN 3223

Type A

Type B

Type C

Type E

Type E

Material

Ductile cast iron, galvanised

Ductile cast iron, galvanised

Steel galvanised

Steel galvanised

Steel galvanised

Application

Hydrants

Pillar hydrants

Underground hydrants and gate valves

Tapping valves

Tapping valves

Length

1100

750

1000

Width

420

320

320

Weight in kg ≈

1,3

2,2

5,7

1,5

2,0

Application, dimensions and weights (dimensions in mm)

small

large

Type A

Type B

Type C / E

A

D

Hook wrench for laying pressure pipes and fittingswith screw-gland joint ( SMU )

DN

40 50 65 80100125150175200250300350400450500

Weight in kg ≈

2,0 2,1 2,4 2,8 3,2 3,5 3,9 5,4 6,8 7,7 9,8 —13,8 — —

Dimensions and weights

Page 117: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

235234 235

55

Laying and assembly instructions

Back to summary

Page 118: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

237236

5

Note

The DVGW standard GW 368 „Thrust-resistant socket joints for pipes, fittings and valves made of ductile cast iron or steel“ is presently being modified.

For up-to-date information please refer to the FGR/EADIPS website at

www.eadips.org.

5.1

Page 119: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

TYTON® ring NOVO-SIT® ring

239238

55.1

General instructionsFor laying pressure pipes, fittings and valves with thrust resisting joint NOVO-SIT®, the “laying instructions for ductile cast iron pressure pipes and fittings with TYTON® joint” should be observed.

Application fieldNOVO-SIT® locking rings are available for the nominal diameters DN 80 up to 800.For the allowable operating pressures, please refer to page 28.This self-anchoring, thrust resisting socket joint substitutes concrete anchoring blocks.

The suitable number of thrust resisting connections has been laid down in DVGW standard GW 368 and has to be observed.Before installation in lines for bridges, ducts or river-crossings, please contact our service team.

Figure: NOVO-SIT® ring with vulcanised segments made of chromium steel. Assembling steps

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint NOVO-SIT®

Page 120: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

240 241

55.1

Segment marking dots

Plates

The exact position of the TYTON® ring has to be tested with a suitable gauge between the segments on the whole circumference.

Note: Deviation of the installed thrust resisting joint is possible as follows: up to DN 400 – 3° up to DN 700 – 2° up to DN 800 – 1°

A pipe with 6 m length and 1° deflection deviates approx. 10 cm off the neutral pipe axis.

Dismantling of thrust resisting joints

Push the spigot completely into the socket.Lubricate the dismantling blades on both sides and drive them into the socket gap at the segment marking dots, with the help of the hammering device.Use the pipe laying tool or dismantling collar to draw the spigot out of the socket.

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint NOVO-SIT®

1. Clean the inside of the socket, particularly the TYTON® groove.2. Insert gasket (TYTON® ring) by deflecting and squeezing, so that the gasket is firmly bedded

in its seating. The inner part of the inserted TYTON® ring should be slightly lubricated.3. Insert NOVO-SIT® ring into the pre-chamber.4. Clean the spigot end and slightly lubricate it, particularly at the rounded end; then insert through

the NOVO-SIT® ring until it touches the the TYTON® ring concentrically. From DN 300 up, this already requires a laying tool.5. Further assembly can be made, depending on the nominal dimension, with a lever or a laying tool.

Deviation should be avoided.

Important:Changes of circumferential directions have to be arranged before connecting ( e.g. installation of outlets, tees a. s. o. ).

Laying device V 300 D

Attention:After connecting both parts, the locking of the segments has to be accomplished by moving the levers in the opposite direction.

Alternate moving of the levers draws the spigot end into the socket Locking

Gauge

Page 121: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

243242

55.1

General instructions

For laying pressure pipes, fittings and valves with thrust resisting joint TYTON® SIT® the “laying instructions for ductile cast iron pressure pipes and fittings with TYTON® joint” should be observed.

Figure: After cleaning, the TYTON® SIT®

thrust resisting ring ( with segments ) has to be deformed acc. to the illustration an inserted into the socket.

Application field: TYTON® SIT® locking rings are available for the nominal diameters DN 80 up to DN 400.For the allowable operating pressures and pressure classes please refer to page 26. This self-anchoring, thrust resisting socket joint substitutes concrete anchoring blocks. The suitable number of thrust resisting connections has been laid down in DVGW-standard GW 368 and has to be observed.

Before installation in lines for bridges, ducts or river crossings, please contact our service team.

Assembling steps 1. Clean the inside of the socket, particularly the TYTON® groove.2. The TYTON® SIT® ring has to be cleaned, deformed acc. to the illustration and inserted into

the socket. Ensure that the S-bend is located between two segments during deformation. The inner part of the inserted TYTON® SIT® ring should be slightly lubricated.

3. Clean the spigot end, slightly lubricate and insert concentrically into the socket until it touches the TYTON® SIT® ring.

4. Mount the laying tool as per the illustration and draw the spigot end into the socket (see page 242).

Deviation should be avoided!

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint TYTON® SIT®

Page 122: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Alternate moving of the levers draws the spigot end into the socket Locking

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint TYTON® SIT®

Important: Changes of circumferential directions have to be arranged before connecting ( e.g. installation of outlets, tees a. s. o. ).

Laying device V 300 D

Attention: After connecting both parts, the locking of the segments has to be accomplished by moving the levers in the opposite direction.

The exact position of the TYTON® SIT® ring has to be tested with a suitable gauge between segments on the whole circumference.

245244

55.1

Dismantling plate

Note:Deviation of the installed thrust resisting joint is possible up to 3°.A pipe with 6 m length and 1° deflection deviates approx. 10 cm off the neutral pipe axis. Dismantling of thrust resisting joints

Push the spigot completely into the socket with the laying tool so the segments are no longer under pressure.Lubricate the dismantling blades on both sides and drive them into the socket gap around the complete circumference, with the help of the hammering device.Use the pipe laying tool or dismantling collar to draw the spigot out of the socket.If it should not be possible to insert the blades around the whole circumference, the pipeline has to be cut. Marking of the installed thrust resisting joint

For a durable marking, we supply a profiled rubber ring with a blue-coloured strip. This marking ring should be applied as shown in the illustration.

Gauge

Page 123: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint TYTON SIT PLUS® (TSP®)

247246

55.1

General instructions

For laying pressure pipes, fittings and valves with thrust resisting joint TYTON SIT PLUS® ( TSP® ), the “laying instructions for ductile cast iron pressure pipes and fittings with TYTON® joint” as well as special installation instructions of the pressure pipe manufacturer should be observed.The TYTON SIT PLUS® sealing and locking ring is available for dimensions DN 80 up to DN 600.

Three basic attributes of the TYTON SIT PLUS® ring are:

Joint construction

marking: “TYTON SIT PLUS®“

notch within the sealing bulge

4 teeth in each segment

TSP® ring with stainless steel segments

TYTON® socket Cast iron pipe

Marking ring

Page 124: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

249248

55.1

Alternate moving of the levers draws the spigot end into the socket Locking

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint TYTON SIT PLUS®

For allowable operating pressures and pressure classes please refer to page 27.

This self-anchoring, thrust resisting socket joint substitutes concrete anchoring blocks. The suitable number of thrust resisting connections has been laid down in DVGW standard GW 368 and has to be observed.Before installation in lines for bridges, ducts or river-crossings, please contact our service team. Assembling steps1. Clean the inside of the socket, particularly

the TYTON® groove.2. The TYTON SIT PLUS® ring has to be

cleaned, deformed acc. to the illustration and inserted into the socket. Ensure that the S-bend is located between two segments during deformation. The inner part of the inserted TYTON SIT PLUS® ring should be slightly lubricated.

3. Push the marking ring, labeled with a white stripe, onto the cast iron pipe.

4. Clean the spigot end, slightly lubricate and insert concentrically into the socket until it touches the TSP® ring.

5. Mount the laying tool as per the illustration and draw the spigot end into the socket.

Deviation should be avoided!

Important:Changes of circumferential directions have to be arranged before connecting ( e.g. installation of outlets, tees a. s. o. ).

Laying device V 300 D

Attention: After connecting both parts, the locking of the segments has to be accomplished by moving the levers in the opposite direction.

The exact position of the TYTON SIT PLUS® ring has to be checked with a suitable gauge between segments on the whole circumference.

Note:Deviation of the installed thrust resisting joint is possible up to 3°.A pipe with 6 m length and 1° deflection deviates approx. 10 cm off the neutral pipe axis.

gauge

Page 125: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

251250Marking of the installed thrust resisting jointWe supply profiled rubber-rings with white stripes. These marking rings should be applied as shown in the illustration. Dismantling of thrust resisting joints

Push the spigot completely into the socket with the laying tool so the segments are no longer under pressure.Lubricate the dismantling blades on both sides and drive them into the socket gap around the complete circumference, with the help of the hammering device.Use the pipe laying tool or dismantling collar to draw the spigot out of the socket.If it should not be possible to insert the blades around the whole

Dismantling plate

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint TYTON SIT PLUS®

Page 126: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Laying instructions for ductile cast iron pressure pipes and fittings, equipped with thrust resisting joint Düker SMU

253252

55.1

General instructions:For laying pressure pipes and fittings with thrust resisting joint Düker SMU, the “laying instruc-tions for ductile cast iron pressure pipes and fittings with screw-gland joint” should be observed. The screw-gland joint Düker SMU only works as thrust resisting joint and gasket, if there is enough space between socket and spigot. The spigot should be drawn into the socket by tightening the screw ring. Only by this way a secure pressing of the gasket is garanteed.

Application field:The thrust resisting joint Düker SMU is available for dimensions DN 40 up to DN 65 and for nominal pressures up to 16 bar (pressure class C50).This self-anchoring, thrust resisting socket joint substitutes concrete anchoring blocks. The suitable number of thrust resisting connections has been laid down in DVGW-standard GW 368 and has to be observed.Before installation in lines for bridges, ducts or river-crossings, please contact our service team. Joint construction

Clean the inside of the socket and the spigot and on a length of at least 300 mm. Drive in the clearance markings L 1 and L 2 with the center punch.

Center punch Block strapping

min. 300 mm

L1

L2

Page 127: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

255254

55.1

Press the gasket evenly into the socket (centering) with the help of the inserting device. Push in the gliding ring and locking ring until the gliding ring touches the gasket.Tighten the screw ring with a hammer or a ram until it cannot be turned any more.

Check the correct installation depth: Block strapping must be within L2 ± 3 mm.After installation of the connection in centrical position, pipes can be deviated

DN 80 – 200 up to 3 ° and DN 250 – 400 up to 2 °

Laying instructions for ductile cast iron pressure pipes and fittings, equipped with thrust resisting joint Düker SMU

Insert the screw ring, locking ring, gliding ring and gasket in this sequence behind the centre punch marking L2. Lubricate the pipe end, face of gasket, gliding ring and locking ring as well as the face and the screw thread of the screw ring with the lubricant supplied by the pipe manufacturer.Insert the pipe end into the socket, centre it and check the installation depth L1.Do not remove lifting gear yet.

Block strapping Gasket Gliding ring Locking ring Screw ring

L1 L2

Block strapping100 mm

DN

Standard socketLong socket

L1

170209

L2

178217

65 L1

164203

L2

172211

50 L1

161200

L2

169208

40

Dimensions L1 and L2 in mm

Page 128: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Laying instructions for ductile cast iron pressure pipes and fittings, equipped with thrust resisting joint Düker SPEZIAL, particulary for flanged sockets and collars

257256

55.1

General instructions: For laying pressure pipes and fittings with thrust resisting joint Düker SPEZIAL, the “laying instructions for ductile cast iron pressure pipes and fittings with screw-gland joint” should be observed.

Enables mounting without block strapping as well as the thrusted-restisting end connection of flanged sockets and collars. Screw ring and SPEZIAL-Screw ring are delivered in blue-grey colour.

Application field: DN 80 – 400, PN 16

For allowable operating pressures and pressures classes please refer to page 31.

Gasket Gliding ring

Element rubber ring with segments / locking ring

SPEZIAL-Screw ring Screw ring

Page 129: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

259258

55.1

For mounting the connection, the following parts are necessary:

Pos. 1: Screw ring made of ductile cast iron, inside chamferedPos. 2: Element rubber-ring with segments made of steelPos. 3: gasketPos. 4: Special screw ring made of ductile cast iron, with internal and external screw threadPos. 5: Simple gliding ring made of steel

Assembling steps:• Clean spigot/s in the area of sealing moves and mark the installation depth.

• Insert screw ring, locking ring/s (DN 80 – 250) or element rubber ring/s (DN 300 + 400), SPEZIAL screw ring/s, gliding ring/s (DN 80 – 400, t = 3 mm) and gasket/s (lubricate inside) in this sequence onto the spigot and pay attention to the correct position (see mounting drawing).

• Lubricate spigot/s, thrust-face/s and outside surface/s of gasket/s, gliding ring/s and locking ring/s (element rubber ring/s), the thrust-face/s and thread of screw rings as well as sealing chambers and the thread of the sockets with lubricant.

• Insert spigot into the socket and check the installation depth. In case of installing a collar also lubricate sealing chambers and thread of screw and insert them onto a spigot. After the axial positioning of spigots to each other (avoid deflection and observe installation depth), put the collar in centre to the spigots and adjust centrically.

• Press the gasket evenly into the sealing chamber, push the gliding ring up to the gasket, screw in the SPEZIAL screw ring by hand as far as possible and tighten it firmly with the help of a hammer or a ram. Avoid the turning of the socket itself.

In case of installing a collar tighten both sides alternately. The turning of the socket can be avoided by using a second hook wrench (see illustration). Because of the setting behaviour of the gasket, a subsequent tightening after 5 to 10 minutes is recommended.

• Push in the locking rings (element rubber rings) until it touches the SPEZIAL screw ring. Insert the screw rings by hand and tighten them with hammer blows.

• Deflection: After finishing the connection in centrical position, pipes can be deflected up to 3°.

258

Laying instructions for ductile cast iron pressure pipes and fittings, equipped with thrust resisting joint Düker SPEZIAL, particulary for flanged sockets and collars

Mounting drawing for collars with thrust resisting joint Düker SPEZIAL

Page 130: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint NOVO-Grip® III

261260

55.1

Gasket NOVO-Grip® III-ring

PE-HD pipe

Application field:NOVO-Grip® III locking rings are available for dimensions DN 90 / 110 / 140 / 160 / 225 and for operating pressures PN 10/16. This self-anchoring, thrust resisting socket joint substitutes concrete anchoring blocks.The suitable number of thrust resisting connections has been laid down in DVGW-standard GW 368 and has to be observed.

Before installation in lines for bridges, ducts or river-crossings, please contact our service team.

Assembling steps1. Clean the inside of the socket and the spigot end.2. Insert gasket into TYTON® chamber.3. Insert NOVO-Grip® III ring into pre-chamber.4. Spigot of pipe has to be rounded and smoothened.5. Insert stabilising bush completely.6. Drive the spreading wedge into the stabilising bush until stretching. Any protruding end of the

spreading wegde has to be cut off so it is flush with the bush.7. Insert pipe into the socket through NOVO-Grip® III ring until touching the gasket.8. Connect the joint by employing commercial pipe-laying tools.

Please avoid deviation while drawing the spigot into the socket!

Important: Changes of circumferential directions have to be arranged before connecting. ( e.g. installation of outlets, tees a. s. o. )

Note: Fittings and valves with a nominal dimension of DN 200 for pipeline diameters of 225 mm do not have a standard Novo socket! These parts are equipped with an adapted geometry and are marked with the sign „for PE-HD Pipes“. Please consider this when you order your pipeline components.

Page 131: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

263262

Laying instructions for ductile cast iron pressure pipes, fittings and valves, equipped with thrust resisting joint NOVO-Grip® III

Gasket (GKS) NOVO-Grip® III ring PE-HD pipe

Dismantling of thrust resisting joints

1. Push in the spigot until it touches the ground of the socket.

2. Lubricate the dismantling plates and drive them in on the whole circumference with the help of the hammering device.

3. Dismantle by using the laying tool.

Attention: Take care of length differences because of variation in temperature when laying plastic pipes.

E.g. PE-HD pipe length 10 m, D t = 10 °; D l approx. 20 mm.

Gasket (GKS)NOVO-Grip® III ring

Dismantling plate

Page 132: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#265264

55.2

Laying Instructions for Bolted-Gland Socket Joints

Laying Instructions for Bolted-Gland Socket Joints

Installation: • Clean the socket (particularly the sealing seat), the spigot to be inserted, the sealing and the

bolted-gland ring

• Mark the distance measure:

• Push the bolted-gland ring and sealing ring behind the marking

DNL

DNL

100160

450172

125160

500172

150160

600180

200162

700182

250162

800190

300165

900197

350165

1000200

400170

1200215

Length of measure L in mm

• Insert the spigot into the socket so a distance of 100 mm is kept between the mark and the flange

Do not use any lubricants!

• Push the sealing into the sealing seat

• Push the bolted-gland ring onto the sealing and align it using hardwood wedges

• Insert hammer head bolts into the bolted-gland flange und the bolted-gland ring

• Screw on the nuts by hand as tightly as possible

• Tighten the nuts with ring spanners one by one (always two nuts facing each other) by a half or one turn each time

Page 133: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#267266

55.2

Laying Instructions for Bolted-Gland Socket Joints

Laying Instructions for Bolted-Gland Socket Joints

The tightening is correct when the bolted-gland ring has pushed itself at least 6 mm into the sealing. The depth can be determined by measuring the height of the bolted-gland ring, and the depth from the edge of the bolted-gland ring up to the sealing ring before and after tightening the bolts. The depth on one bolted-gland socket joint should be as uniform as possible.

Control the correct depth once more.

Angle: After tightening the joint in a centred and aligned position, the pipes can be put in an angle of up to 3°.An angle of 1° results in a deviation of a 6 m pipe from the axis of the connected pipe or fitting by approx. 10 cm; for 3° it is approx. 30 cm.

Fittings with bolted-gland socket joints in DN 1400 and 1600 are supplied with specific installation instructions which must be observed in detail.

The marking of the distance measure (275 mm for DN 1400 and 1600) and the insertion of the bolted-gland ring and the sealing correspond to page 264.

Then assemble the bolts with the washers and insert them. Lubricate the bolt threads and screw on the nuts and washers by hand while aligning the sealing.

Then tighten the nuts one by one, always two nuts facing each other. The socket flange and the bolted-gland ring must remain parallel and never differ by more than 15 mm. The required torque is 150 ±20 Nm.

Before the pressure test, control the torque once more.

Deflection: After mounting the joint in a centred and aligned position, the pipes can be deflected by up to 2°.Attention: in this case tighten the bolts at first with a torque of only 60 ±10 Nm, and after deflection tighten with 150 ±20 Nm.

DN 1400 and 1600

Hexagonal head bolts and washers instead of hammer head bolts

Page 134: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

Assembly instructions for pressure pipes and fittings with flanges

269268

55.3

Assembly instructions for pressure pipes and fittings with flanges

1. Clean the flange, raised face and gasket. Check all parts for proper conditions. Do not use damaged parts.

2. In case of installation with unprotected screws, especially in soils with corrosion risk, the screw connections must be protected ( f. e. with bituminous tapes ).

3. Pipes and fittings must be bedded carefully and the filling and compacting of the pipe ditch must be done carefully as well. Pipes and fittings should never be supported with stones or similar hard material and must be laid on stonefree base. Rocky base must be covered with min. 15 cm layer of sand, gravel or split.

4. For flanged pipes and fittings the general rule for the arrangements of the boltholes is that no bolthole is located in the flange axis, which is upright to the pipeline level.

5. Notes for the installation of flanged fittings ( in particular double flanged tapers / FFR ):

To avoid installation errors, special installation marks ( notches ) are cast on at the flanges in opposite positions. It is necessary to ensure that these marks are arranged for installation in vertical or horizontal direction.

Page 135: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

271270

55.4

Assembly instructions for drilling saddle pieces

Required tools: • core drilling machine• core bit Ø 172 +1,5/-0 mm for DN 150• core bit Ø 232 +1,5/-0 mm for DN 200• drilling machine or cordless electric drill• hammer• punch• carbide drill Ø 13 mm (e.g. DIN 8037)• file• brush• lubricant (included in the delivery)• protective paint

Assembly:

Step 1: Drill into the sewage pipe with the core drilling machine and the corresponding core bit.

Example: Double flanged taper ( FFR ) 350 / 250, PN 10

right wrong

In case of wrong installation and due to the unequal number of boltholes on double-flanged tapers, the connecting valves or fittings will be slanting from the vertical axis. Possible deviations are up to 22.5°, depending on the diameter.

Attention:On large diameters, a deviation is hardly detectable!

Remarks:Please note that DVGW standard-workingsheet GW 368 should be observed.

Assembly instructions for pressure pipes and fittings with flanges

Page 136: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#273272

55.4

Step 2: Deburr, clean, dry and repaint the drilling edges with a fast-drying epoxy resin paint. On sewage pipes with external cement mortar coating, this coating is to be removed in the contact area of the spot-drilling saddle piece.

Step 3: Insert the saddle sealing into the drill hole. Fit on the saddle piece and mark the position of the screw holes on the pipe by punching through the screw holes of the saddle piece. Then remove the saddle piece and the sealing.

Assembly instructions for drilling saddle pieces

Assembly instructions for drilling saddle pieces

Step 4: Drill two holes on the punch marks with the 13 mm carbide drill. Then insert the screws and sealing sleeves contained in the delivery into the drill holes from the inside and drive them cautiously through with a hammer.

Step 5: Re-insert the saddle sealing into the drill hole. Watch out for exact positioning. Apply lubricant to the sealing and put on the saddle piece.

Page 137: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

#275274

66

Contacts

Assembly instructions for drilling saddle pieces

Step 6: Screw on the nuts lightly, then tighten alternatively and evenly until the saddle piece connects. Do not use any lever that might damage the coating (use e.g. a square timber).

Page 138: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

277276

6

Contacts

Mr Gerald WernerExport ManagerTel. +49 6093 87 250E-Mail [email protected]

Mr Thomas EckelTel. +49 6093 87 211E-Mail [email protected]

Ms Julia RossmanithTel. +49 6093 87 252E-Mail [email protected]

Düker GmbH & Co. KGaAExport Dept. Fittings and ValvesD-63846 LaufachTel. +49 6093 87 560Fax +49 6093 87 246E-Mail [email protected]

Ms Nicole EichTel. +49 6093 87 181E-Mail [email protected]

Ms Tanja RaabTel. 49 6093 87 237E-Mail [email protected]

Ms Dorothee FleckensteinTel. +49 6093 87 262E-Mail [email protected]

Ms Lena RüthTel. +49 6093 87 414E-Mail [email protected]

Page 139: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The

FITTINGS AND VALVES

DRAINAGE TECHNOLOGY

GLASS LINING TECHNOLOGIES

JOBBING FOUNDRY

For further information on our product programme please refer to our web site:

http://www.dueker.de

Back to summary

Page 140: Index: Fittings, flanged pipes and valves made of …...Fittings, flanged pipes and valves made of ductile cast iron (GGG) Index: (click with mouse) Düker in general Preamble The