in block of flats flat solar collectors m a to dietrisol ... eg315 er136 eg317 eg319 4 pces (2) 1 2...
TRANSCRIPT
267www.dedietrich-heating.com
Sol
ar in
stal
lati
ons
15
optionS: see page 278
main dimenSionS (mm and inches) Vertical or horizontal assembly
according to the model
- Flat, high-performance collectors for horizontal (PRO C250H) and vertical (PRO C250V) mounting on roof, terrace or roof integration
- Flat absorber in aluminium with selective coating and single-pipe exchanger, sinusoid in shape, Ø 10 mm, laser-welded, connected to 2 collector pipes Ø 22 mm for connection in series in batteries (up to 10 collectors)
- Insulation in rock wool, rear thickness 40 mm- Casing in anthracite grey painted aluminium profiling with
fastening groove on the surround and rear closing cover in aluminium
- Translucid pane in safety glass, thickness 3.2mm, translucency > 91%
- Mounting systems for terraces, roof and roof integration, hydraulic connection kits and kits for interconnecting collectors and collector fields
- Multi-use in systems with forced circulation of heat-carrying fluid provided by us, ex drain-back
PRO
C_Q
0005
Flat solar collectorsDIETRISOL PRO C250V and PRO C250H
For domestic hot water production for installations in block of flats
KEY MARK : PRO C250V : 11-7S1362FPRO C250H : 11-7S1363F
1147
2187
87 87
2187
1147
2044
1004
PROC_F0001B
PRO C250V PRO C250H
4 x Cu 22 4 x Cu 22
1147
2187
87 87
2187
1147
2044
1004
PROC_F0001B
PRO C250V PRO C250H
4 x Cu 22 4 x Cu 22 PRO
C_F
0001
B
technical SpeciFicationSOperating pressure: 2.5 barMax. operating pressure: 10 bar
Max. operating temperature: 120°C
PRO C250V PRO C250H
SLO
OTDIEMA
Model DIETRISOL PRO C250H PRO C250VTotal gross area (Ag) m2 2.51 2.51Input area (Aa) m2 2.37 2.37Absorber area (AA) m2 2.354 2.354Fluid capacity l 2.9 2.9Recommended fl ow rate l/h. 50-250 50-250Fluid resistance (30 l/h.m2) mbar 75 85Test pressure bar 10 10Absorber factor (a) % > 95 +/- 1 > 95 +/- 1Emissivity (ξ) % > 5 +/- 1 > 5 +/- 1Optical yield (ηOA) % 81.2 81.4Transmission loss coeff. (a1) W/m2.K 3.641 3.639Transmission loss coeff. (a2) W/m2.K2 0.0128 0.0089Weight empty kg 47 47
Model DIETRISOL PRO C250H PRO C250VPackage ER241 ER240
Ref. 100016503 100016502
a
+ point
PR
OJE
CT
www.dedietrich-heating.com268
Sol
ar in
stal
lati
ons
15
Reference listof the packages required installations in block of flats up to 10 collectors PRO C250V
DÉSIGNATIONPACKAGE REF. Number of PRO C250V
collectors mounted in parallel on 1 line
1 2 3 4 5 6 7 8 9 102.4 m2 4.8 m2 7.1 m2 9.5 m2 11.9 m2 14.3 m2 16.7 m2 19 m2 21.4 m2 23.8 m2
PACKAGED FLAT COLLECTORS
1 fl at collector PRO C250V ER240 100016502 1 2 3 4 5 6 7 8 9 10
ACCESSORIES FOR THE HYDRAULIC CONNECTION OF THE PRO C250V COLLECTOR
Hydraulic connection kit for a collector fi eld ER245 100016506 1 1 1 1 1 1 1 1 1 1Hydraulic connection kit between 2 collectors ER246 100016507 - 1 2 3 4 5 6 7 8 9Hose kit for connecting a collector fi eld to the solar circuit (optional) ER247 100016508 1 1 1 1 1 1 1 1 1 1
TERRACE (OR GROUND) MOUNTING SYSTEMS
Systems for high loads of wind and snow (High Load)- Basic HL terrace support for mounting 1 x PRO C250V ER250 100016509 1 1 1 1 1 1 1 1 1 1- Extension HL terrace support for mounting 1 x additional PRO C250V ER251 100016510 - 1 2 3 4 5 6 7 8 9orSystems for standard loads of wind and snow (Standard Load)- Basic SL terrace support for mounting 1 x PRO C250V ER658 7217038 1 1 1 1 1 1 1 1 1 1- Extension SL terrace support for mounting 1 x additional PRO C250V ER659 7217039 - 1 2 3 4 5 6 7 8 9- Clip-on profi le kit for 1 x PRO C250V ER664 7217044 1 2 3 4 5 6 7 8 9 10
ROOF INTEGRATION MOUNTING SYSTEMS
- Basic kit for integration in mechanical tile � 22° for 1 x PRO C250V (1) ER634 7212864 1 - - -- Basic kit for integration in mechanical tile � 22° for 2 x PRO C250V (1) ER635 7212869 - 1 1 1- Extension kit for integration in mechanical tile � 22° for 1 x additional PRO C250V ER636 7212867 - - 1 2- * With fl at/slates tiles, order a fl ashing kit ER558 7503269 1* 1* 1* 1* 1* 1* 1* 1*or- Basic kit for integration in canal tile � 17° for 1 x PRO C250V ER640 7212872 1 - - -- Basic kit for integration in canal tile � 17° for 1 x PRO C250V ER641 7503821 - 1 1 1- Extension kit for integration in canal tile � 17° for 1 x additional PRO C250V ER642 7212875 - - 1 2
ROOF MOUNTING SYSTEMS (profi le kit and anchorage fi ttings)
- Clip-on profi le kit for 1 x PRO C250V(for use in combination with the anchorage fi ttings below) ER664 7217044 1 2 3 4 5 6 7 8 9 10
ANCHORAGE FITTING FOR TILED ROOF INSTALLATION (4)
For roofs without rafters- Universal aluminium hook for mechanical tile
8980F077D sans cote
4 pces EG311 89807311 1 2 1 2 1 2 16 pces EG312 89807312 - 1 1 2 1 2 3 2 3
(Mounting on 2 battens, min. cross section 30 x 90mm, provided) cm not delivered 300 300 400 600 700 800 1000 1200 1300 1400Fitting on hooks (except EG 311/EG 312)Tiles** Mechanical Flat Canal Sheeting Slates
(stainless steel) (stainless steel) (stainless steel) (stainless steel) (stainless steel)EG313 EG315 ER136 EG317 EG319 4 pces (2) 1 2 1 2 1 2 189807313 89807315 100015314 89807317 89807319EG314 EG316 ER137 EG318 EG320 6 pces (2) - 1 1 2 1 2 3 2 389807314 89807316 100015315 89807318 89807320
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
- Coach bolt kit for mounting on canal tile 6 pces EG94 89807782 1 2 1 4 2 6 5 8 pces EG95 89807783 - 1 2 2 2 4** for other types of tiles, contact us(1) With fl at/slates tiles: order a fl ashing kit-package ER 558, Ref. 7503269(2) To be chosen according to the type of roofi ng as well as the profi les(4) � In areas with heavy snow and roof slopes ≤ 35°, the number of hooks should be doubled
For an optimized calculation use our tool"DIEMATOOLS"
SLO
OT
DIEMA
Sol
ar in
stal
lati
ons
15
269www.dedietrich-heating.com
Reference Listof the packages required installations in block of flats up to 10 collectors PRO C250H
DESCRIPTIONPACKAGE REF. Number of PRO C250H
collectors mounted in parallel on 1 line
1 2 3 4 5 6 7 8 9 102.4 m2 4.8 m2 7.1 m2 9.5 m2 11.9 m2 14.3 m2 16.7 m2 19 m2 21.4 m2 23.8 m2
PACKAGED FLAT COLLECTORS
1 fl at collector PRO C250H ER241 100016503 1 2 3 4 5 6 7 8 9 10
ACCESSORIES FOR THE HYDRAULIC CONNECTION OF THE PRO C250H COLLECTOR
Hydraulic connection kit for a collector fi eld ER245 100016506 1 1 1 1 1 1 1 1 1 1Hydraulic connection kit between 2 collectors ER246 100016507 - 1 2 3 4 5 6 7 8 9Hose kit for connecting a collector fi eld to the solar circuit (optional) ER247 100016508 1 1 1 1 1 1 1 1 1 1
TERRACE (OR GROUND) MOUNTING SYSTEMS
Systems for high loads of wind and snow (High Load)- Basic HL terrace support for mounting 1 x PRO C250H ER252 100016511 1 1 1 1 1 1 1 1 1 1- Extension HL terrace support for mounting 1 x additional PRO C250H ER253 100016512 - 1 2 3 4 5 6 7 8 9orSystems for standard loads of wind and snow (Standard Load)- Basic SL terrace support for mounting 1 x PRO C250H ER656 7217041 1 1 1 1 1 1 1 1 1 1- Extension SL terrace support for mounting 1 x additional PRO C250H ER657 7217042 - 1 2 3 4 5 6 7 8 9- Clip-on profi le kit for 1 x PRO C250H ER662 7217048 1 2 3 4 5 6 7 8 9 10
ROOF INTEGRATION MOUNTING SYSTEMS
- Basic kit for integration in mechanical tile � 22° for 1 x PRO C250H (1) ER637 7212866 1 - - -- Basic kit for integration in mechanical tile � 22° for 2 x PRO C250H (1) ER638 7212870 - 1 1 1- Extension kit for integration in mechanical tile � 22° for 1 x additional PRO C250H ER639 7212868 - - 1 2- * With fl at/slates tiles, order a fl ashing kit ER558 7503269 1* 1* 1* 1*or- Basic kit for integration in canal tile � 17° for 1 x PRO C250H ER643 7212873 1 - - -- Basic kit for integration in canal tile � 17° for 2 x PRO C250H ER644 7212880 - 1 1 1 Extension kit for integration in canal tile � 17° for 1 x additional PRO C250H ER645 7212877 - - 1 2
ROOF MOUNTING SYSTEMS (profi le kit and anchorage fi ttings)
- Clip-on profi le kit for 1 x PRO C250H(for use in combination with the anchorage fi ttings below) ER662 7217048 1 2 3 4 5 6 7 8 9 10
ANCHORAGE FITTING FOR TILED ROOF INSTALLATION (4)For roofs without rafters- Universal aluminium hook for mechanical tile
8980F077D sans cote
4 pces EG311 89807311 1 2 - 1 2 - 1 2 - 16 pces EG312 89807312 - - 2 2 2 4 4 4 6 6
(Mounting on 2 battens, min. cross section 30 x 90mm, provided) cm not delivered 300 500 700 900 1200 1400 1600 1800 2000 2300Fitting on hooks (except EG 311/EG 312)Tiles** Mechanical Flat Canal Sheeting Slates
(stainless steel) (stainless steel) (stainless steel) (stainless steel) (stainless steel)EG313 EG315 ER136 EG317 EG319 4 pces (2) 1 2 - 1 2 - 1 2 - 189807313 89807315 100015314 89807317 89807319EG314 EG316 ER137 EG318 EG320 6 pces (2) - - 2 2 2 4 4 4 6 689807314 89807316 100015315 89807318 89807320
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
8980F077D sans cote
- Coach bolt kit for mounting on canal tile 6 pces EG94 89807782 1 2 1 4 2 6 5 8 pces EG95 89807783 - 1 2 2 2 4** for other types of tiles, contact us1) With fl at/slates tiles: order a fl ashing kit-package ER 558, Ref. 7503269(2) To be chosen according to the type of roofi ng as well as the profi les(4) � In areas with heavy snow and roof slopes ≤ 35°, the number of hooks should be doubled
For an optimized calculation use our tool"DIEMATOOLS"
SLO
OT
DIEMA