imporatnt elements of clean air equipments
TRANSCRIPT
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
1/19
i) Housing- Material of construction should becompatible to the standards.
ii) Filters - Pre filters- Intermediate filters
- Fine / Final / Terminal filter
iii) Motor Blower assembly-
iv) Indicating instrument-v) Lighting arrangement-
vi) Electrical controls-
IMPORTANT ELEMENTS OF THE CLEAN
AIR EQUIPMENTS
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
2/19
i) Material of construction-
ii) Laminarity of Air Flow
iii) Filtration level & its integrity-iv) Safety level-
v) Sound level-
vi) Vibrations-
vii) Lighting level on work surface-
viii) Easy for operations & maintenance-
ix) Competitive Price-
IMPORTANT DESIGN PARAMETERS OF THE
CLEAN AIR EQUIPMENTS.
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
3/19
AIR SHOWER
It gives shower of sterile air with high velocity airjets, which helps to remove suspended particles,
bacterias on the clothing of personnel or the
material being taken inside the clean room
PRINCIPLE OF OPERATION :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
4/19
Air shower is installed at entry of
i) Clean rooms
ii) Operation theaters
iii) Calibration laboratoryiv) Electronic industries
v) Food processing
vi) Paint Shopvii) Germs & jewelry for recovering of gold
Application areas for Air Shower
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
5/19
It sucks the surrounding air & blows through
special designed rectangular nozzle at a veryhigh speed ( 2400FPM to 3600FPM) which
forms invisible curtain between the controlled
and uncontrolled environment.
AIR CURTAINS
PRINCIPLE OF OPERATION :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
6/19
It is fitted or suspended at top of the doors
i) Pharmaceutical
ii) Operation theatersiii) Food Processing,
iv) Dairy
v) Sweet mart & Honey collection centers
vi) Cold storages as a thermal barrier
vii) Show rooms & Offices
Application areas of Air Curtains
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
7/19
LAMINAR FLOW WORK STATION
HORIZONTAL
PRINCIPLE OF OPERATION :-
It sucks the room air through pre-filter anddelivers into work area through HEPA filter at
laminar air flow. Laminar air flow is horizontal.
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
8/19
LAMINAR FLOW WORK STATION
VERTICAL
PRINCIPLE OF OPERATION :-
It sucks the room air through pre-filter anddelivers into work area through HEPA filter at
laminar air flow. Laminar air flow is vertical.
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
9/19
i) Laboratories- R& D Biotechnology, Pathology
labs
ii) Institutes- Agriculture, Pharma, Biotechnologyiii)Hospitals- Pathology lab, Blood bank
iv)Industries- Electronics, Food processing,
Calibration, Watch mfg & repairing,Pharmaceutical, Bearing assly
v) Agriculture- Tissue culture
Application areas of LAF :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
10/19
FILTERATION MODULES
It re-circulates the room air through pre-filter &
fine filter so as to achieve the defined no of air
changes per hour. It helps to maintain the air bornecontamination level of room as per the clean room
cleanliness class. All the airborne contaminants gets
trapped in the HEPA filter so it needs to be
re laced after eriod of time.
PRINCIPLE OF OPERATION :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
11/19
i) Laboratories- R& D Biotechnology, Pathology
labs
ii) Institutes- Pharma, Biotechnology, Agricultural
iii)Hospitals- Operation theaters & ICU
iv)Industries- Electronics, Food processing,
Calibration, Watch mfg & repairing,Pharmaceutical, Bearing assembly
v) Agriculture- Tissue culture
Application areas of FM :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
12/19
ELECTROSTATIC
AIR PRECIPITATION UINT
It consists of pre-filter and electrostatic air
precipitator unit, in which fine dust particles up to
0.1 micron are gets collected on stack plates which
are connected high DC voltage.
PRINCIPLE OF OPERATION :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
13/19
Main advantage of this ESP unit is that it doesn't
require separate blower unit if installed in series
with the existing AHU system.
Stack assembly can be cleaned & reused again.
Hence power consumption & operational cost is
very low compare to HEPA filtration units.
Only drawback of this ESP unit is low filtration
efficiency as compare to HEPA filtration units.
PRINCIPLE OF OPERATION :-
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
14/19
Application areas of ESP :-
i) It is always recommended to use in series
with existing Air Handling Unit to reduce theburden on terminal HEPA filters & extend the
life .
ii) Self air circulating ESP units are suitable tomaintain air borne contaminant level in the
Telephone exchange, Server Rooms &
Broadcasting, which enhances the life ofelectronics being used.
iii)Precision machine shops, calibration labs,
quality control depts & banks.
FUME HOODS
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
15/19
FUME HOODS
Fume hood is confined work chamber and designedto collect all fumes generated on worktop during
the process and exhaust directly to the environment
through filtration system.Application areas
-Research laboratories
-Pharma
-Chemical industries
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
16/19
STERI AIR
STERI AIR is a small & compact filtration
unit with pre-filter, HEPA filter , Activated
Carbon Filter and Negative ionizer.
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
17/19
Longevity is suitable for,
-Small Offices,
-Bars & Restaurant to minimize the cigarettesmoke,
-Server Rooms,
-Patients having asthma, allergy, headache &fatigue .
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
18/19
GARMENT CABINETS
Garment cabinet consists of pre-filter, HEPA filter
Blower assembly & UV light. This provides sterile
environment for the sterile Garment, curb growth
of bacteria .
-
8/13/2019 Imporatnt Elements of Clean Air Equipments
19/19
These Clean Air Equipments are designed forhazardous area Zone 1, Gr IIA/ IIB application
like,
-Pertochemical industries,
-Pharma industries where highly inflammable
chemicals are used-Satellite launching station,
-Chemical industries ,ammunition industries
CLEAN AIR EQUIPMENTS FOR
HAZARDOUS AREA APPLICATIONS