Impedance Measurement System for Determination
of Capacitive Electrode Coupling
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, VOL. 7, NO. 5, OCTOBER 2013
Benjamin Eilebrecht, Johannes Willkomm, Antje Pohl, Student Member, IEEE, Tobias Wartzek, and Steffen Leonhardt, Senior Member, IEEE
Adviser: Ji-Jer HuangPresenter: Hou-Yu ChouDate: 103/3/19
![Page 2: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/2.jpg)
Outline
1. Introduction2. Materials and Methods3. Results4. Discussion5. Conclusion & Outlook
![Page 3: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/3.jpg)
Introduction
ECG:– Advantages:
better signals– Disadvantages: 1. skin irritations2. specific preparation before
measurements 3. limitations related to the
connecting cables
http://140.134.32.60:83/news/test/biotech/bei/bei.html 102/12/9
![Page 4: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/4.jpg)
Introduction
Capacitive ECG : Advantages:– does not need contact– make continuous – an office chair, a bed, a toilet seat , automobile
Disadvantages: – still suffer from strong artifacts
![Page 5: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/5.jpg)
Introduction
• This paper presents a combined impedance and ECG measurement system based on capacitive electrodes,which allows simultaneous measurement of the ECG and the coupling impedance of the electrodes.
![Page 6: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/6.jpg)
Introduction
• Common ECG-systems measure the impedance between two electrodes in order to warn against a removal of electrodes.
http://www.macaodaily.com/res/1/20131217/49051387214448609.jpg 103/2/26
![Page 7: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/7.jpg)
Introduction
• The combination of an impedance measurement unit and a capacitive biosignal measurement could be beneficial– the coupling impedance
can easily result in the range of some GΩ
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 58, NO. 5, MAY 2011
![Page 8: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/8.jpg)
MATERIALS & METHODS
• Two units: one to measure the ECG and the other to measure the impedance
• The signal separation can be done with a passive high and an active low pass filter with cut-off frequencies of 1500 and 100 Hz Bioimpedance(BIS)
![Page 9: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/9.jpg)
MATERIALS & METHODS
![Page 10: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/10.jpg)
MATERIALS & METHODS
• MUX– Switch between the
different electrodes serve as a reference
for the remaining electrodes
3-dimensional construction
![Page 11: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/11.jpg)
MATERIALS & METHODS
• Driven right leg circuit, with a negative amplification of 1000. – the common mode
rejection ratio is markedly enhanced
![Page 12: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/12.jpg)
MATERIALS & METHODS
• The impedance measurement unit generally consists of a current source for injecting a current into the human body and a voltage measurement circuit to detect the voltage drop over the segment
BIS Measurement
Inject current
Detect voltage drop
Impedance
![Page 13: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/13.jpg)
MATERIALS & METHODS
• Determine both the coupling and the bioimpedance, – allowing to switch
between the different electrodes was necessary
![Page 14: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/14.jpg)
MATERIALS & METHODS
• Four-pointmeasurement– a current is injected by
two electrodes, whereas the voltage drop is measured by two different electrodes
• Two-pointmeasurement– the same electrodes for
both the injection of the current as well as for measurement of the voltage drop
![Page 15: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/15.jpg)
MATERIALS & METHODS
• EL₁ and EL₂ uses Z₁,in
and Z₂,in for the current injection
• Z₁,meas and Z₂,meas to measure the voltage drop
![Page 16: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/16.jpg)
MATERIALS & METHODS
![Page 17: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/17.jpg)
MATERIALS & METHODS
• The ring electrode– the outer ring was used
to measure the voltage drop
– the inner area for current injection
![Page 18: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/18.jpg)
MATERIALS & METHODS
• Both the resistance and the capacitance can be calculated from the real and imaginary part of the coupling impedance
![Page 19: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/19.jpg)
MATERIALS & METHODS
• Before applying the system to human, the system was tested :– The bioimpedance unit
was tested separately on a dummy circuit and with a galactose polymer.
– calculated for different clothing materials and thicknesses http://spinoff.nasa.gov/spinoff2002/t_2.html 103/2/26
![Page 20: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/20.jpg)
MATERIALS & METHODS
• The distance between the electrodes was also tested to establish
![Page 21: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/21.jpg)
Results
• The first channel shows a flat line
• In the other channels, the characteristic ECG waveforms with the representative R-peak can be seen
![Page 22: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/22.jpg)
Results
• Frequencies between 25 kHz and 500 kHz
• Measurements at frequencies below 25 kHz result in significant deviations
![Page 23: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/23.jpg)
Results
![Page 24: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/24.jpg)
Results
![Page 25: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/25.jpg)
Results
• The four-point measurements of the galactose polymer– dummy resulted in
impedances between 2kΩ and 4kΩ ,
http://www.ebay.com/itm/Lifesize-Dummy-soft-MANNEQUIN-female-Dress-body-Form-Mannequin-upper-torso-bust-/281229752393
103/2/26
![Page 26: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/26.jpg)
Results
• From a combined two and four-point measurement, the real and imaginary part of the coupling impedance, using a single cotton layer as insulation material, could be calculated as:15k Ω
![Page 27: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/27.jpg)
Results
• With the electrode area A=16.6 cm² , textile thickness d = 0.5mm , dielectric constant ϵᵣ= 1 (almost air) and electrical conductivity ρ=10⁷Ωcm.
• Applying these values to(1)and(2)
![Page 28: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/28.jpg)
Discussion1. According to the theory, such doubling should halve
the coupling capacitance, which was not observed.
2. The results were achieved under controlled conditions and will be degraded in real scenarios
3. Even if the galactose-polymer model was the best choice for mimicking a real skin-electrode interface—show much lower resistive fractions of the coupling impedance than expected.
![Page 29: Impedance Measurement System for Determination of Capacitive Electrode Coupling](https://reader035.vdocuments.mx/reader035/viewer/2022081508/56813c6e550346895da5fea6/html5/thumbnails/29.jpg)
Conclusion & Outlook
1. The model assumption of a capacitive coupling with a resistive fraction were in the order as expected.
2. An extension of the system to spectrometric measurements is required and will be explored in the future.
3. Increasing the number of electrodes in the system will increase the order of the system of equations used to calculate the impedances