ihx visteon

17
Strictly Private and Confidential Climate Electronics Interiors Lighting IHX R1234yf Marek Pernicky, Nov 10 2010

Upload: rmmmzi

Post on 28-Nov-2014

146 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: IHX Visteon

Strictly Private and Confidential

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

IHX R1234yf

Marek Pernicky, Nov 10 2010

Page 2: IHX Visteon

Page 2

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Presentation outline

� Market trends, drivers

� R1234yf vs. R134a

� Project scope

� Technical assumption

� Results

� Conclusion

Page 3: IHX Visteon

Page 3

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Market trends, drivers

� EU legislation

– Fuel economy legislation: CO2 emission

� Affects 65% of new car registrations in 2012, 75% in 2013, 80% in 2014,

100% in 2015

– Low GWP refrigerant – Ban of R134a

� US Greenhouse Gas Rules

– US Environmental Protection Agency rules to reduce greenhouse gases and

improve fuel economy for MY2012-2016 passenger cars, light duty trucks, and

medium duty passenger vehicles

– Includes credits for A/C system efficiency improvements and low leakage

systems, including the use of a low GWP refrigerant

– Internal Heat Exchanger specifically called out and provides 1.1 g/mi of CO2

credit

Page 4: IHX Visteon

Page 4

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Market trends, drivers

� Consumer & Customer demands

– Lower fuel consumption

– Lower cost

– Less leakage & higher reliability

– Reduced NVH

– Reduce component weight (less kg to accellerate,

less fuel consumption, less CO2 emissions)

– Reduced package size

– Fast response to late design changes

Eco friendly products and technologies

Page 5: IHX Visteon

Page 5

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Visteon response

� Enviromently friendly products and technologies aligned to

recent world trend. One of the technologies for emission

improvement include IHX.

� In order to follow EU and US legislation requirements calling for

improved and enviromentaly friendly systems, Visteon has

developed IHX for R134a and R1234yf.

� Internal Heat Exchanger with innovative coaxial tube design

integrated in the refrigerant circuit for enhanced system

performance (cooling capacity) and efficiency.

� Replaces a part of the suction and liquid refrigerant lines to

exchange energy in a counter-flow arrangement.

R/D

IHX

HP

IHX

LP

Condenser

Evaporator

Page 6: IHX Visteon

Page 6

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf vs R134a

� Thermodynamic properties of R1234yf near to R134a

– Pressure range nearly equal

– Pressure ratio ↓ (discharge/suction)

– Evaporation enthalpy ↓

– Density of gas at suction side ↑

� Test results show a drop of 0 to 10 % in cooling capacity and COP

in these “near drop in” systems

� Lower compressor outlet temperature requires higher efficiency of IHX

Internal heat exchanger may reduce lack of capacity

2,23

2,38

COP /-

93,789,57,772,2R1234yf

1001008,684,0R134a

Potential /%Potential /%Q0 /kWt2 /°C

Energetic Analysis

Page 7: IHX Visteon

Page 7

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

0,00

1,00

2,00

3,00

4,00

5,00

6,00

7,00

8,00

9 8 7 6 5 4 3 2 1

Point

Ca

pa

cit

y [

kw

]

R134a baseline

R134a IHX

R1234yf baseline

R1234yf IHX

R1234yf Drop in evaluation – capacity (current IHX design)

Capacity of R1234yf is ~5% lower than R134a

Lower capacity can be compensated for with an IHX

Page 8: IHX Visteon

Page 8

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf Drop in evaluation – COP (current IHX design)

Impact on COP is similar to cooling power

Lower COP R1234yf can be compensated with an IHX

Page 9: IHX Visteon

Page 9

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Project goals & scope

� Scope:

– Improve system capacity and COP for R1234yf refrigerant compared to an

R134a system with IHX

� Goals & objectives:

– Develop internal heat exchanger for R1234yf refrigerant

– Consider already known requirements

– Review various concepts and perform trade-offs

– Proceed with most “effective” concept (performance vs. cost)

– Improved design of IHX having equivalent performance of R134a system

with current IHX design for full compensation of lower cooling power

– high efficiency IHX – coax tube or stand alone IHX

Solution to close a performance gap

Page 10: IHX Visteon

Page 10

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Technical assumption

� Size

– Use maximum allowable length & outer diameter in existing vehicle space

� Geometry

– Increase IHX performance to offset lower performance of R1234yf (when base

is R134a with IHX)

– Increase IHX performance due to lower compressor discharge temperature

with minimal additional pressure loss

� Manufacturing feasibility

� Refrigerant properties - R1234yf

– Discharge temperature with stronger IHX to be cooler than R134a

– ~70%-120% increase of qIHX required

– Additional pressure loss may reduce potential contribution of IHX

Optimal size vs. performance with minimal pressure loss

Page 11: IHX Visteon

Page 11

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf IHX - Discharge temperature

Proposal meets maximum allowable discharge temperature ~ 130°C

Page 12: IHX Visteon

Page 12

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf IHX - efficiency

Double efficiency

118%

Page 13: IHX Visteon

Page 13

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf IHX - capacity

118%

Double performance

Page 14: IHX Visteon

Page 14

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf IHX – pressure loss

+51 mbar

+66 mbar

Acceptable pressure loss

Page 15: IHX Visteon

Page 15

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

R1234yf IHX - real efficiency

Real efficiency improvement is 95% from current IHX design considering pressure drop

Page 16: IHX Visteon

Page 16

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

Conclusion

� Improved efficiency of IHX with R1234yf is required to achieve performance

equivalent to R134a with IHX

� Use of an IHX in R1234yf systems can offset performance degradation (5 to 10%)

when compared to R134a

� Coaxial tube IHX is a cost effective solution that minimizes added pressure drop

compared to stand alone heat exchangers

Visteon’s Coaxial tube IHX is a proven production solution

Page 17: IHX Visteon

Page 17

Climate ●●●● Electronics ●●●● Interiors ●●●● Lighting

www.visteon.com