Page 1: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

IHE-RO 2007RT Objects Integration

Bruce Curran Bruce Curran Assistant Professor / University of Michigan

Page 2: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

RT Objects Integration ProfileRT Objects Integration Profile

The integration profile for 2007 involves The integration profile for 2007 involves the flow of DICOM images and treatment the flow of DICOM images and treatment planning data, from CT scan through dose planning data, from CT scan through dose display, for 3D conformal, external beam display, for 3D conformal, external beam radiation therapy. The emphasis for this radiation therapy. The emphasis for this first Integration Profile is on reducing first Integration Profile is on reducing ambiguity and facilitating basic ambiguity and facilitating basic interoperability in the exchange of DICOM interoperability in the exchange of DICOM RT objects. RT objects.

Page 3: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Integration Profile Transactions

• Single/Contoured Image Series RetrieveSingle/Contoured Image Series Retrieve

• Structure Set StorageStructure Set Storage

• Geometric Plan StorageGeometric Plan Storage

• Dosimetric Plan StorageDosimetric Plan Storage

• Dose StorageDose Storage

• Multi-Series Image RetrieveMulti-Series Image Retrieve

• Structure Set RetrieveStructure Set Retrieve

• Geometric Plan RetrieveGeometric Plan Retrieve

• Dosimetric Plan RetrieveDosimetric Plan Retrieve

• Dose RetrieveDose Retrieve

• Resampled/ Combined CT Series StorageResampled/ Combined CT Series Storage

Page 4: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Single/Contoured Image Series Retrieval

• In the Single/Contoured Image Series In the Single/Contoured Image Series Retrieve transaction, the Archive sends a Retrieve transaction, the Archive sends a series of CT-Images to the series of CT-Images to the ContourerContourer, , Geometric PlannerGeometric Planner, , Dosimetric Planner Dosimetric Planner or or Dose DisplayerDose Displayer..

Single/Contoured Image Series

Retrieval

Archive

Contourer, Geometric Planner,Dosimetric Planner,

Dose Displayer

Page 5: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Structure Set Storage

• In the Structure Set Storage Transaction, In the Structure Set Storage Transaction, the the ContourerContourer stores a Structure Set on an stores a Structure Set on an

Archive to make it available.Archive to make it available.

Structure Set Storage

Archive Contourer

Page 6: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Geometric Plan Storage

• In the In the Geometric Plan Geometric Plan Storage transaction, Storage transaction, the the Geometric PlannerGeometric Planner sends the newly sends the newly created created Geometric Plan Geometric Plan to the Archive.to the Archive.

Geometric Plan Storage

Archive Geometric Planner

Page 7: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Dosimetric Plan Storage

• In this transaction, the Dosimetric Planner sends the plan containing the references to the structure set to the Archive.

Dosimetric Plan Storage

Archive Dosimetric Planner

Page 8: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Dose Storage

• In the Dose Storage transaction, the Dose planner sends the newly created Dose to the Archive.

Dose Storage

Archive Dosimetric Planner

Page 9: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Multi-Series Image Retrieve

• In the Multi-Series Image Retrieve Transaction, the Archive stores CT Images from multiple series (but a single study) on a Contourer to make these Images available for contouring.

Multi-Series Image Retrieval

Archive Contourer

Page 10: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Structure Set Retrieval

• In the Structure Set Retrieval Transaction, the Archiver stores a Structure Set on a Contourer, Geometric Planner, Dosimetric Planner, or Dose Displayer.

Structure Set Retrieval

Archive

Contourer, Geometric Planner,Dosimetric Planner,

Dose Displayer

Page 11: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Geometric Plan Retrieve

• In the Geometric Plan Retrieve Transaction, the requested Geometric Plan is transferred from the Archive to the Dosimetric Planner.

Geometric Plan Retrieval

Archive Dosimetric Planner

Page 12: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Dosimetric Plan Retrieve

• In this transaction, the dose displayer retrieves the plan containing the references to the structure set to the Archive.

Dosimetric Plan Retrieval

Archive Dose Displayer

Page 13: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Dose Retrieve

• In the Dose Retrieve Transaction, the requested Dose is transferred from the Archive to the Dose Displayer.

Dose Retrieval

Archive Dose Displayer

Page 14: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Resampled/Combined CT Series Storage

• In the Resampled/Combined CT Series Storage Transaction, the Contourer stores CT Images which have been combined or resampled into a single series on the Archive.

Resampled/Combined CT Series

Storage

Archive Contourer

Page 15: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Profile Testing Participants2006

Page 16: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Informal Connectathon 2006

•25+ participants, 9 Vendors, 10+ systems25+ participants, 9 Vendors, 10+ systems•95+ monitored test cases95+ monitored test cases

Page 17: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Informal Connectathon 2006

Page 18: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Informal Connectathon 2006

Page 19: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

Informal Connectathon 2006

Page 20: IHE-RO 2007 RT Objects Integration Bruce Curran Assistant Professor / University of Michigan

IHE-RO 2006 Connectathon