1/13 www.edison-opto.com Copyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice. version : 2.1 Edison Opto Corporation 4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist., New Taipei City 235,Taiwan Tel:+886 28227 6996 Fax:+886 28227 6997 OPTO Laboratory Test Report Report NO. Q130401 Report Number Q130401 Test Sample 2PHM30WW38P13001 Rating DC 720mA 30W Normal CCT 3,000 K Test Date 1. 55 o C,70 o C,85 o C (Apr. 11, 2013 to Jan. 13, 2014) 2. 105 o C (Oct. 31, 2013 to Mar. 17, 2014) Test Address 9F, NO.800, Chung-Cheng Rd., Chung-Ho Dist., New Taipei City 235, Taiwan Test Standard IES LM-80-08 Approved Method : Measuring Lumen Maintenance of Led Lighting Sources Temp. Measure point See page 3 Description of test equipment See page 3 Test Engineer Amos Huang Review By Kenny Yen Notes: 1. The test center executes the test operations with prudent manners. All the test results are detail stated in the report. All test service meet under the regulations of ISO/IEC 17025. 2. The report is only responsible to the assigned test. It shall not be any of the bases of Compliance judgments. 3. There are 13 pages in the test report (include the cover page). It is invalid when being used separately. 4. The test report is forbidden to reproduce in separate pages. The complete report copy is unrestricted. 5. The recorded contents in this report shall not be used as advertising, publications or merchandising purposes without written permissions by the test center. 6. Lumen maintenance(lm) uncertainty=6.2%; Chromaticity(x,y) uncertainty=0.0002. IES LM-80-08 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE

Upload: vandang

Post on 09-Mar-2018

362 views

Category:

Documents


15 download

TRANSCRIPT

Page 1: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

1/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

Report Number Q130401

Test Sample 2PHM30WW38P13001

Rating DC 720mA 30W

Normal CCT 3,000 K

Test Date1. 55oC,70oC,85oC (Apr. 11, 2013 to Jan. 13, 2014)2. 105oC (Oct. 31, 2013 to Mar. 17, 2014)

Test Address9F, NO.800, Chung-Cheng Rd., Chung-Ho Dist., New Taipei City 235, Taiwan

Test StandardIES LM-80-08 Approved Method : Measuring Lumen Maintenance of Led Lighting Sources

Temp. Measure point See page 3

Description of test equipment

See page 3

Test Engineer Amos Huang

Review By Kenny Yen

Notes:1. The test center executes the test operations with prudent manners. All the test results are detail stated in the report. All test service meet under the regulations of ISO/IEC 17025.2. The report is only responsible to the assigned test. It shall not be any of the bases of Compliance judgments.3. There are 13 pages in the test report (include the cover page). It is invalid when being used separately.4. The test report is forbidden to reproduce in separate pages. The complete report copy is unrestricted.5. The recorded contents in this report shall not be used as advertising, publications or merchandising purposes without written permissions by the test center.6. Lumen maintenance(lm) uncertainty=6.2%; Chromaticity(x,y) uncertainty=0.0002.

IES LM-80-08 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE

Page 2: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

2/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

According to section 3 item 7 and section 4 item 5 of ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module Lumen Maintenance Performance Data Supporting Qualification of Lighting Products, the test report also applies to the following products:

Part Number Normal CCT Watt W/mm^2

2PHM30WW38P13001 3000K 30 0.074

2PHM30NW38P13001 4000K 30 0.074

2PHM30CW38P13001 5700K 30 0.074

2PHM16WW38P13001 3000K 16 0.037

2PHM16NW38P13001 4000K 16 0.037

2PHM16CW38P13001 5700K 16 0.037

2PHM30WW27P13001 3000K 30 0.074

2PHM30NW27P13001 4000K 30 0.074

2PHM30CW27P13001 5700K 30 0.074

2PHM16WW27P13001 3000K 16 0.037

2PHM16NW27P13001 4000K 16 0.037

2PHM16CW27P13001 5700K 16 0.037

2PHM24WW27P13001 3000K 24 0.061

2PHM24NW27P13001 4000K 24 0.061

2PHM24CW27P13001 5700K 24 0.061

Page 3: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

3/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

Equipment Model No. / Serial No. Cal. Laboratory Report No. Effective Date

Integrating sphere ISP25045392012

Deutscher Akkreditierungs RatDAT-PL-293/09-00

CAL-141-12-058 02.08.2014

DC power source KEITHLEY 24004000282

Tai YiTAF-1625 T3306141201 17.06.2014

Temperature controlled test

VEKTREX/ SpikeSafe 2001080030009

Tai YiTAF-1625

T3305240801

27.05.2014

VEKTREX/ ITCS 428 T3305240701

VEKTREX/ ITCS 429 T3305240702

VEKTREX/ ITCS 430 T3305240703

Ts Measurement Point2. Case and ambient temperatureThe case temperature Ts is the temperature on the substrate; the ambient temperature TA is the temperature of the air at a distance of 50 mm above substrate.

3. Description of test equipment

1. Test Summary

Case temperature (Ts) 53oC ≤ Ts 68oC ≤ Ts 83oC ≤ Ts 103oC ≤ Ts

Ambient conditions (TA)50oC ≤ TA

R.H. < 65 % Minimized airflow

65oC ≤ TA R.H. < 65 %

Minimized airflow

80oC ≤ TA R.H. < 65 %

Minimized airflow

100oC ≤ TA R.H. < 65 %

Minimized airflow

Sample Size 10 10 10 10

Drive current of the LED 720mA 720mA 720mA 720mA

Initial flux (lm) / VF(V) 2641.9 / 36.9 2637.2 / 36.9 2629.1 / 36.9 2649.7 / 37.5

Lumen maintenance at 7000 hrs 98.33% Page 5

96.36% Page 7

96.01% Page 9

98.17% Page 11

LED failure 0 0 0 0

Monitoring interval (hrs) 0,1000,2000,3000,4000,5000,6000,7000 0,1000,2000,3000

Chromaticity shift Page 6 Page 8 Page 10 Page 12

Ts

Page 4: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

4/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

Package Dimensions and Polarity

16W/ 30W Emitter Dimensions

Notes : 1. Unit : mm2. Tolerance : ± 0.2 mm3. Drawings are not to scale4. TP : Thermal measurement point

16W EdiPower® II HM Series Circuit Layout

16W/ 30W Emitter Circuit Layout

(1)

(2)

(3)

30W EdiPower® II HM Series Circuit Layout

(1)

(2)

(6)

1.6

17

1

R2.00

19

19

7.1

9.5

5.59.5R2.00

9.5

7.1

1.6

3.2 5.5 9.5

3.2

1.6

Page 5: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

5/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2663.3 1.000 0.998 1.000 0.997 1.001 0.995 0.990 0.986

2 2613.6 1.000 0.997 0.998 0.995 1.000 0.994 0.991 0.985

3 2643.8 1.000 0.996 1.001 1.000 0.993 0.988 0.985 0.979

4 2670.1 1.000 0.996 0.997 0.995 0.999 0.994 0.990 0.987

5 2657.4 1.000 0.996 0.998 0.996 0.989 0.984 0.981 0.976

6 2621.0 1.000 0.996 0.992 0.992 0.992 0.985 0.985 0.978

7 2627.7 1.000 0.994 0.992 0.990 0.989 0.985 0.983 0.978

8 2677.4 1.000 0.996 0.990 0.990 0.994 0.987 0.986 0.982

9 2651.3 1.000 0.997 0.998 0.994 0.989 0.983 0.983 0.977

10 2629.7 1.000 0.997 0.993 0.993 0.991 0.984 0.982 0.977

AVG 2645.5 1.000 0.996 0.996 0.994 0.994 0.988 0.985 0.980

MIN 2613.6 1.000 0.994 0.990 0.990 0.989 0.983 0.981 0.976

MAX 2677.4 1.000 0.998 1.001 1.000 1.001 0.995 0.991 0.987

4. Test Results 4.1 Lumen and Color Maintenance data (55 oC)

■ Lumen Maintenance data (55 oC)

Page 6: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

6/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

∆ u’v’

No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2752.4 0 0.0001 0.0002 0.0006 0.0004 0.0003 0.0002 0.0004

2 2755.0 0 0.0001 0.0002 0.0004 0.0003 0.0002 0.0002 0.0003

3 2740.8 0 0.0001 0.0003 0.0004 0.0005 0.0004 0.0002 0.0001

4 2753.2 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0002 0.0003

5 2742.1 0 0.0001 0.0002 0.0004 0.0003 0.0002 0.0001 0.0002

6 2750.9 0 0.0001 0.0003 0.0006 0.0002 0.0001 0.0003 0.0004

7 2753.5 0 0.0002 0.0002 0.0005 0.0002 0.0002 0.0003 0.0004

8 2755.3 0 0.0001 0.0003 0.0006 0.0002 0.0001 0.0003 0.0004

9 2744.5 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0001 0.0002

10 2753.4 0 0.0001 0.0003 0.0006 0.0003 0.0002 0.0004 0.0005

AVG 2750.1 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0002 0.0003

MIN 2740.8 0 0.0001 0.0002 0.0004 0.0002 0.0001 0.0001 0.0001

MAX 2755.3 0 0.0002 0.0003 0.0006 0.0005 0.0004 0.0004 0.0005

■ Color Maintenance data (55 oC)

Test Condition 1 - 55⁰C Case Temp

Sample size 10

Number of failures 0

DUT drive current used in the test (mA) 720

Test duration (hours) 7,000

Test duration used for projection (hour to hour) 2,000 - 7,000

Tested case temperature (⁰C) 55

α 3.141E-06

B 1.004

Calculated L70(7k) (hours) 115,000

Reported L70(7k) (hours) >39000

Page 7: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

7/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

4.2 Lumen and Color Maintenance data (70 oC)

■ Lumen Maintenance data (70 oC)

No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2658.6 1.000 0.997 1.006 1.000 0.989 0.984 0.962 0.950

2 2608.7 1.000 0.996 1.000 0.998 1.001 0.994 0.981 0.975

3 2634.3 1.000 0.998 0.998 0.997 0.993 0.986 0.976 0.968

4 2628.8 1.000 0.996 0.993 0.985 0.968 0.963 0.941 0.935

5 2654.0 1.000 0.996 0.991 0.991 0.991 0.987 0.974 0.970

6 2673.5 1.000 0.995 0.999 0.993 0.987 0.981 0.969 0.965

7 2620.2 1.000 0.997 0.995 0.993 0.992 0.989 0.977 0.970

8 2623.4 1.000 0.996 0.993 0.989 0.979 0.977 0.963 0.958

9 2649.3 1.000 0.997 0.996 0.998 0.997 0.997 0.982 0.976

10 2620.9 1.000 0.996 0.995 0.996 0.998 0.991 0.975 0.970

AVG 2637.2 1.000 0.996 0.997 0.994 0.989 0.985 0.970 0.964

MIN 2608.7 1.000 0.995 0.991 0.985 0.968 0.963 0.941 0.935

MAX 2673.5 1.000 0.998 1.006 1.000 1.001 0.997 0.982 0.976

Page 8: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

8/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

∆ u’v’

■ Color Maintenance data (70 oC)

Test Condition 2 - 70⁰C Case Temp

Sample size 10

Number of failures 0

DUT drive current used in the test (mA) 720

Test duration (hours) 7,000

Test duration used for projection (hour to hour) 2,000 - 7,000

Tested case temperature (⁰C) 70

α 7.062E-06

B 1.015

Calculated L70(7k) (hours) 53,000

Reported L70(7k) (hours) >39000

No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2743.4 0 0.0001 0.0007 0.0005 0.0009 0.0008 0.0008 0.0016

2 2754.2 0 0.0001 0.0006 0.0005 0.0005 0.0002 0.0004 0.0004

3 2752.0 0 0.0001 0.0006 0.0005 0.0005 0.0003 0.0003 0.0003

4 2756.6 0 0.0001 0.0005 0.0006 0.0012 0.0011 0.0002 0.0002

5 2744.0 0 0.0001 0.0006 0.0005 0.0006 0.0005 0.0002 0.0002

6 2748.8 0 0.0001 0.0006 0.0006 0.0009 0.0009 0.0006 0.0005

7 2754.2 0 0.0001 0.0005 0.0005 0.0006 0.0004 0.0003 0.0002

8 2750.3 0 0.0000 0.0005 0.0006 0.0009 0.0008 0.0006 0.0004

9 2741.8 0 0.0001 0.0008 0.0006 0.0006 0.0004 0.0003 0.0002

10 2749.4 0 0.0001 0.0005 0.0004 0.0005 0.0003 0.0002 0.0001

AVG 2749.5 0 0.0001 0.0006 0.0005 0.0007 0.0006 0.0004 0.0004

MIN 2741.8 0 0.0000 0.0005 0.0004 0.0005 0.0002 0.0002 0.0001

MAX 2756.6 0 0.0001 0.0008 0.0006 0.0012 0.0011 0.0008 0.0016

Page 9: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

9/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

4.3 Lumen and Color Maintenance data (85 oC)

■ Lumen Maintenance data (85 oC)

No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2611.0 1.000 0.995 0.997 0.997 0.984 0.977 0.970 0.957

2 2686.8 1.000 0.993 0.996 0.996 0.990 0.985 0.979 0.963

3 2626.0 1.000 0.995 0.997 0.997 0.992 0.984 0.977 0.964

4 2653.2 1.000 0.993 0.993 0.995 0.988 0.980 0.973 0.958

5 2683.2 1.000 0.994 0.999 0.999 0.996 0.988 0.983 0.970

6 2599.8 1.000 0.992 0.995 0.998 0.996 0.990 0.984 0.970

7 2602.9 1.000 0.994 0.997 0.997 0.987 0.984 0.976 0.961

8 2611.9 1.000 0.993 0.991 0.984 0.967 0.963 0.955 0.941

9 2600.8 1.000 0.995 0.996 0.994 0.983 0.976 0.969 0.955

10 2615.9 1.000 0.994 0.989 0.991 0.991 0.986 0.977 0.963

AVG 2629.1 1.000 0.994 0.995 0.995 0.987 0.981 0.974 0.960

MIN 2599.8 1.000 0.992 0.989 0.984 0.967 0.963 0.955 0.941

MAX 2686.8 1.000 0.995 0.999 0.999 0.996 0.990 0.984 0.970

Page 10: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

10/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

∆ u’v’

■ Color Maintenance data (85 oC)

Test Condition 3 - 85⁰C Case Temp

Sample size 10

Number of failures 0

DUT drive current used in the test (mA) 720

Test duration (hours) 7,000

Test duration used for projection (hour to hour) 2,000 - 7,000

Tested case temperature (⁰C) 85

α 7.077E-06

B 1.014

Calculated L70(7k) (hours) 52,000

Reported L70(7k) (hours) >39000

No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2756.6 0 0.0001 0.0005 0.0004 0.0007 0.0005 0.0004 0.0003

2 2749.6 0 0.0001 0.0004 0.0003 0.0004 0.0002 0.0003 0.0003

3 2747.4 0 0.0001 0.0004 0.0003 0.0003 0.0003 0.0004 0.0005

4 2740.2 0 0.0001 0.0007 0.0005 0.0005 0.0003 0.0001 0.0002

5 2755.2 0 0.0001 0.0004 0.0003 0.0003 0.0002 0.0004 0.0004

6 2750.4 0 0.0003 0.0005 0.0004 0.0005 0.0003 0.0005 0.0006

7 2756.8 0 0.0002 0.0005 0.0004 0.0005 0.0002 0.0003 0.0003

8 2756.9 0 0.0002 0.0005 0.0006 0.0012 0.0009 0.0007 0.0006

9 2753.8 0 0.0001 0.0005 0.0004 0.0005 0.0003 0.0002 0.0003

10 2746.4 0 0.0001 0.0006 0.0005 0.0004 0.0003 0.0004 0.0005

AVG 2751.3 0 0.0001 0.0005 0.0004 0.0005 0.0004 0.0004 0.0004

MIN 2740.2 0 0.0001 0.0004 0.0003 0.0003 0.0002 0.0001 0.0002

MAX 2756.9 0 0.0003 0.0007 0.0006 0.0012 0.0009 0.0007 0.0006

Page 11: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

11/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

4.3 Lumen and Color Maintenance data (105 oC)

■ Lumen Maintenance data (105 oC)

No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2657.8 1.000 0.995 0.987 0.982 - - - -

2 2610.7 1.000 0.992 0.986 0.979 - - - -3 2669.7 1.000 0.995 0.989 0.982 - - - -4 2672.4 1.000 0.993 0.989 0.981 - - - -5 2673.9 1.000 0.994 0.985 0.981 - - - -6 2637.1 1.000 0.993 0.988 0.983 - - - -7 2645.8 1.000 0.994 0.989 0.984 - - - -8 2631.7 1.000 0.994 0.987 0.982 - - - -9 2637.1 1.000 0.994 0.985 0.981 - - - -

10 2661.1 1.000 0.993 0.988 0.982 - - - -AVG 2649.7 1.000 0.994 0.987 0.982 - - - -MIN 2610.7 1.000 0.992 0.985 0.979 - - - -MAX 2673.9 1.000 0.995 0.989 0.984 - - - -

Page 12: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

12/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

∆ u’v’

■ Color Maintenance data (105 oC)

Test Condition 4 - 105⁰C Case Temp

Sample size 10

Number of failures 0

DUT drive current used in the test (mA) 720

Test duration (hours) 3,000

Test duration used for projection (hour to hour) 1,000 - 3,000

Tested case temperature (⁰C) 105

α -

B -

Calculated L70(7k) (hours) -

Reported L70(7k) (hours) >39000

No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h

1 2716.5 0 0.0001 0.0004 0.0005 - - - -

2 2750.0 0 0.0003 0.0004 0.0006 - - - -

3 2761.5 0 0.0002 0.0003 0.0006 - - - -

4 2733.2 0 0.0003 0.0004 0.0006 - - - -

5 2727.7 0 0.0002 0.0005 0.0005 - - - -

6 2766.7 0 0.0003 0.0004 0.0005 - - - -

7 2728.0 0 0.0002 0.0004 0.0004 - - - -

8 2726.0 0 0.0002 0.0004 0.0005 - - - -

9 2723.1 0 0.0002 0.0005 0.0005 - - - -

10 2726.6 0 0.0002 0.0004 0.0005 - - - -

AVG 2735.9 0 0.0002 0.0004 0.0005 - - - -

MIN 2716.5 0 0.0001 0.0003 0.0004 - - - -

MAX 2766.7 0 0.0003 0.0005 0.0006 - - - -

Page 13: IES LM-80-08 - EDISON Opto Corporation Edison Opto Corporation

13/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.

version : 2.1

Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997

OPTO Laboratory Test Report

Report NO. Q130401

About Edison Opto

Edison Opto is a leading manufacturer of high power LED and a solution provider experienced in LDMS. LDMS is an integrated program derived from the four essential technologies in LED lighting applications- Thermal Management, Electrical Scheme, Mechanical Refinement, Optical Optimization, to provide customer with various LED components and modules. More Information about the company and our products can be found at www.edison-opto.com

Copyright©2014 Edison Opto. All rights reserved. No part of publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photo copy, recording or any other information storage and retrieval system, without prior permission in writing from the publisher. The information in this publication are subject to change without notice.

www.edison-opto.com

For general assistance please contact:[email protected]

For technical assistance please contact:[email protected]

5. EPA Recognized Certification Laboratory Information

EPA Recognized Certification Bodies (CBs) and Laboratories List ResultsNotes:1. Only accredited laboratories are listed on this page. Laboratories that are EPA-recognized through enrolling in a Certification Body's WMTL or SMTL program are not listed here.2. EPA encourages manufacturers to contact laboratories directly to ensure they have the capability and availability to test the particular products for which certification is sought, as some product types may require special testing equipment or capabilities. Manufacturers must also confirm with an EPA-recognized certification body (CB) that the laboratory is acceptable under the CB's program for that product type.3. Windows, Doors, and Skylights partners are advised to contact the National Fenestration Rating Council(www. nfrc.org ) for a complete list of EPA-recognized laboratories for these products.4. Lighting (CFLs, ILLs, Luminaires, and Decorative Light Strings) Labs and CBs are listed separately.5. Please note, EPA recognizes the Association of Home Appliance Manufacturers (AHAM) only for administering verification testing.

Organization ID

Organization Name

Type of Recognized

Body

If Lab is it 1st Party? Programs Organization

Address City State Country

1114690

Edison Opto Corporation - OPTO Testing

Laboratory

Accredited Laboratory Y Luminaires

4F, NO.800, Chung-Cheng Rd., Chung-Ho

Dist.,

New Taipei City

- TW