iecex certificate ofconformity - emerson topworx documents/… · iecex certificate ofconformity...
TRANSCRIPT
IECEx Certificateof Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSIONIEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.:
Status:
Date of Issue:
Applicant:
Electrical Apparatus:Opilonalaccessory:
IECEx SIR 14.0078X
Current
2015-07-07
TopWorx3300 Fern Valley RoadLouisvilleKentucky 40213United States of America
0-5eries Switchbox
issue No.:O
Page 1 of 3
Certificate history:
Type of Protection:
Marking:
Intrinsic Safety and Dust Protection by Enclosure
Ex ia IIC T4 Gb orEx ia IIC T6 GbEx tb IIiC T*oC DbTa =_*oC to +*oC*The temperature class and ambient temperature depends on the electrical devices that arefitted in the Switchbox, see the Conditions of Manufacture.
Approved for issue on behalf of the IECExCertification Body:
Position:
C Ellaby
Deputy Certification Manager
Signature:(for printed version)
Date:
1. This certificate and schedule may only be reproduced in full.2. This certificate is not transferable and remains the property of the issuing b y.3. The Status and authenticity of this certificate may be verified by visiting the a IC'
Certificate issued by:SIRA Certification Service
CSA GroupUnit 6, Hawarden Industrial Park
HawardenOeesideCH53US
United Kingdom
siraCERTIFICATION
CSAOroup
Certificate No.:
IECEx Certificateof Conformity
IECEx SIR 14.0078X
Date of Issue:
Manufacturer:
2015-07-07
TopWorx3300 Fern Valley RoadLouisvilleKentucky 40213United States of America
Issue No.: 0
Page 2 of3
Additional Manufacturing location(s):Emerson Machinery Emerson ProcessEquipment (Shenzhen) ManagementCo. Ltd. Magyarorszag Kft.Fisher Controls Division Fisher Controls InternationalBao Heng Technology LLCIndustry Park Holland Fasor 6Liu Xian 1st Road SzekesfehervarDistrict 68, Bao'an District 8000Shenzhen 518101 HungaryChina
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested andfound to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex productscovered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. Thiscertificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documentsas amended.
STANDARDS:The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identifieddocuments, was found to comply with the following standards:
IEC 60079-0 : 2011Edition: 6.0IEC 60079-11 : 2011Edition: 6.0IEC 60079-31 : 2013Edition: 2
Explosive atmospheres - Part 0: General requirements
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
This Certificate does not indicate compliance with electrical safety and performance requirements other than thoseexpressly included in the Standards listed above.
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:GB/SIR/ExTR15.0178/00
Quality Assessment Report:
GB/BAS/QAR06.0020/06 GB/BAS/QAR13.0005/01 GB/SIR/QAR07.0025/05
Certificate No.:
IECEx Certificateof Conformity
IECEx SIR 14.0078X
Date of Issue: 2015-07-07
Schedule
Issue No.: 0
Page 3 of 3
EQUIPMENT:Equipment and systems covered by this certificate are as follows:
The D-Series Switchbox is a valve position indicator. A rotating cam activates a number of internal devices thatsense the status of the valve position. The Switchbox consists of an enclosure made up of a body and a lid. Allmodels have a visual valve position indicator underneath a plastic dome. The body has threaded entries to allow theinstallation of cable glands.The approved internal devices are as shown in the Conditions of Manufacture.
Enclosures tvDesModel Body Lid DomeDXP Aluminium Aluminium LexanDXS Stainless steel Stainless steel LexanDXR Resin Resin Lexan
Refer to ANNEXE for Conditions of Manufacture.•
CONDITIONS OF CERTIFICATION: YES as shown below:
Refer to ANNEXE.
Annex: IECEx SIR 14-0078X_Annexe Iss O.pdf
Annexe to:
Applicant:
Apparatus:
IECEx SIR 14.0078X Annexe Issue 0
TopWorx
D-Series Switchbox
CSAGroup
Conditions Of Manufacture
The Manufacturer shall comply with the following:
i. The manufacturer shall subject 100% of completed units to the dielectric strength test in accordance withlEe 60079-11:2011 clauses 6.3.12 and 10.3, by applying a voltage of 500 Vrms to all input terminals andthe outer enclosure for a minimum of 60 s. Alternatively, a voltage of 700 Vrms may be applied for 1 s.The current flowing during the test shall not exceed 5 mAo
ii. When the equipment incorporates a 4-20 mA Transmitter Module, the output shall only be connected to aNovotechnic WAL305 potentiometer.
iii. The certification codes, ambient temperature ranges and (where applicable) dust temperature markingshall be as shown in the table below. The ambient temperature range marked is dependent on the internaldevices fitted and shall reflect the most restrictive values.
Limiting ambient temp. range
Ex ia IIC T4 Gb Ex ia IIC T6 Gb(3.78W max.) (1.36W max.)
Device Style Type Description DXS/DXP (8 K DXR (15 K DXS/DXP DXR (13 Kinternal temp. internal (3 K internal internalrise) temp. rise) temp, rise) temp. rise)
Mechanical switch K V7 Simple Switch
Micro/Limit Switch M VSlONOO1C2 Simple Switch
Reed Switch P HSR-V933 Simple Switch -60°C to -60°C to -60°C to -60°C to
Reed Switch R LV-ELE145 Simple Switch +92oC +85OC +70oC +60oC
Go Switch L/Z 35 Series Simple Switch
DPDT Micro T/8 Cherry Burrell E19 or Simple SwitchSwitch TIW DPDT-ZZ #26-804
Line fault - - Not certified. -60°C to -60°C to Not Notdetection -600C to + 1000C +92°C +85OC permitted permitted
Topworx Cube PN 2 reed switch with LEDs Not certified. -60°C to -60°C to Not Not-600C to + 1000C +92°C +85OC permitted permitted
4-20 mA HART H Encapsulated module Not certified, -50°C to -50°C to -50°C to -50°C toboard -500C to +550C +47oC +40oC +52oC +42oC
ASCO Electro- lor 302l...,IA IECEx INE 1O,0002X -40°C to -40°C to Not Not assessedvalve 2 issue 1; +82oC +75OC assessed for forT6
Ex ia IIC T6/T5/T4 T6-40oC to 40/50/900C
IFM Electronic N N*50**, N95001 & IECEx BVS 06.0003 -20°C to -200C to -20°C to -20°C toInductive K15030 issue 4 +52°C +450C +57oC +47oCProximity Switch Ex ia IIC T6 Ga
-200C to +60oCPepperl & Fuchs N SJ... & SC... IECEx TUN 04.0016X -60°C to -60°C toSlot Type T4: with supply types 1, issue 0 +67°C +60oCInitiators 2 +3 only Ex ia IICT4
-600C to +750CT6: with supply type 1 Ex ia IICT6 -60°C to -60°C toonly -600C to +72oC +69OC +59OC
Pepperl & Fuchs N NCN-...-N4..., PL.-F25.- IECEx TUN 04.0014X -60°C to -60°C to -60°C to -60°C toValve Position N4..., NC..-F31.-N5... issue 0 +74oC +67oC +59OC +49OCsensor (with supply types 1, 2 Ex ia IICT6
+3 only) T4: -600C to +82oCT6 (Type 1): -60°C to+62oC
Date: 07 July 2015 Page 1 of 3
Sira Certification ServiceUnit 6, Hawarden Industrial Park,
Hawarden, CH5 3US, United Kingdom
Form 9530 Issue 1Tel:Fax:Email:Web:
+44 (0) 1244670900+44 (0) 1244 539 [email protected]
Annexe to:
Applicant:
Apparatus:
IECEx SIR 14.0078X Annexe Issue 0
TopWorx
D-Series Switchbox
CSAGroup
Limiting ambient temp. range
Ex ia IIC T4 Gb Ex ia IIC T6 Gb(3.78W max.) (1.36W max.)
Device Style Type Description DXS/DXP (8 K DXR (15 K DXS/DXP DXR (13 Kinternal temp. internal (3 K internal internalrise) temp. rise) temp. rise) temp. rise)
Pepperl & Fuchs E Type NJ2-V3-N... only IECEx PTB 11.0021X -60°C to -60°C to -60°C to -60°C toCuboidal (with supply types 1, 2 issue 0 +81OC +74OC +70oC +60oCInductive +3 only) Ex ia IIC T4/T6 GaProximity sensor -60°C to +89/73OC
All other types (with Ex ia IIC T4/T6 Ga -60°C to -60°C to -60°C to -60°C tosupply types 1, 2 +3 -60°C to +63/550C +5SOC +48°C +52°C +42OConly)
TopWorx 4-20 mA X N/A IECEx SIR 12.0076U -40oC to -40°C to Not NotTransmitter issue 0 +72oC +65°C permitted permittedModule and Ex ia IIC Gaassociated -400C to +80oCpotentiometerTurk Two Wire N Type ...- ...-.Y1.-..../ ... IECEx KEM 06.0036X -25°C to -25°C to -25°C to -25°C toProximity Sensors issue 3 +62oC +55°C +67oC +57oC
Ex ia IIC T4/T6 Gb-250C to +70oC
Group III (dust) minimum ambient temperature (silicone 57395-60 flange 0- -60°C -20°C -60°C -20°Crino, S70R2 shaft O-rinos)Group III (dust) maximum ambient temperature: As Gp. II 40°C As Gp. II 42°CEx tb IIIC T*0C Db where T*0C is: Ta(max) + T550C Ta(max) + T550C
14 K 10KIP rating: IP66/67 IP67 IP66/67 IP67
Since the exact composition of the Valve Position Indicators is variable, the manufacturer shall:• Supply the installer/end user with a full set of appropriate certificates and instructions that are
relevant to the contents of the enclosure;• Ensure that the installer/end user can identify which certified sub-assemblies are fitted to each Valve
Position Indicator.
Conditions Of Certification
The user/installer shall comply with the following:
i. The Switchbox may contain one or more devices covered by the following certificates:
Description Certificate numberASCO Electro-valve Module type 3021.. ..IA IECEx INE 1O.0002X issue 1.
If fitted, the entity parameters are Ui = 28 V, Ii = 300 mA,Pi = 1.6 W Ci = 0 Li = O.
IFM inductive proximity switch type NE****, IECEx BVS 06.0003 issue 4.NF****, NG****, NI****, NN****, NT****, Refer to certificate for entity parameters specific to the modelNS**** number.Pepperl & Fuchs slot-type initiators, types SJ... IECEx TUN 04.0016X, issue 0&SC... If a T6 temperature class is marked, the input entity
parameters to sensors covered by this certificate (if fitted)shall be limited to Ui = 16 V, Ii = 25 mA, Pi =34 mW C'type1" supply)
Pepperl & Fuchs Valve Position sensor types IECEx TUN 04.0014X, issue O.NCN-...-N4... , PL.-F25.-N4... , NC..-F31.-N5... If a T6 temperature class is marked, the input entity
parameters to sensors covered by this certificate (if fitted)shall be limited to Ui = 16 V, Ii = 25 mA, Pi = 34 mW C'type1" supply).
Sira Certification ServlceDate: 07 July 2015 Page 2 of 3
Unit 6, Hawarden Industrial Park,
Hawarden, CH5 3US, United Kingdom
Form 9530 Issue 1Tel:Fax:Email:Web:
+44 (0) 1244 670 900+44 (0) [email protected]
Annexe to:
Applicant:
Apparatus:
IECEx SIR 14.0078X Annexe Issue 0
TopWorx
D-Series Switchbox
CSAGroup
Description Certificate numberPepperl & Fuchs cuboidal inductive sensors, IECEx PTB 11.0021X issue 0type NJ... If a T6 temperature class is marked, the input entity
parameters to sensors covered by this certificate (if fitted)shall be limited to Ui = 16 V, Ii = 25 mA, Pi =34 mW ("type1" suoolv),
Topworx4-20 mA Transmitter Module IECEx SIR 12.0076U issue 1.If fitted, the entity parameters are Ui = 30 V, Pi = 1.5 W,Ci = 0, Li = O. Ii can be any value from an intrinsically safesource meetinq the Ui and Pi reauirements.
Turck two-wire proximity sensors type ...-....- IECEx KEM 06.0036X, issue 3..y1.-...../. ... Refer to certificate for entity parameters specific to the model
number.
The installer shall confirm which certified sub-assemblies are contained within the equipment and ensurecompliance with the appropriate certificate (with particular reference to entity parameters).
ii. If fitted, the entity parameters for the HART 4-20 board are: Ui = 28 V, Ii = 100 mA, Pi = 0.7 W,Ci = 14 nF, Li = 2.06 mH
iii. If fitted, the entity parameters for uncertified simple mechanical or reed switches (including the TopworxR2 and R4 Cubes), with or without line fault detection, are Ui = 3 OV, Ii = 200 mA and Pi = 0.34 W perswitch circuit.
iv. If fitted, the entity parameters for the Topworx PN Cube are Ui = 28 V, Ii = 250 mA and Pi = 0.8 W perswitch circuit.
v. The supplies to all internal devices shall be treated as separate intrinsically safe circuits.
vi. The DXP version of the Switchbox has an enclosure that is manufactured from aluminium alloy. In rarecases, ignition sources due to impact and friction sparks could occur. This shall be considered when theequipment is installed.
vii. The plastic parts of the Switchbox may generate an ignition-capable level of electrostatic charge.Therefore the equipment shall not be installed in a location where the external conditions are conducive tothe build-up of electrostatic charge on such surfaces. In addition, the equipment shall only be cleanedwith a damp cloth.
viii. When marked for use in flammable dust, the DXR (resin) enclosure shall only be installed where there is alow risk of mechanical damage.
ix. The air pressure to the valve block, when fitted, shall not exceed 10.0 bar.
Date: 07 July 2015 Page 3 of 3
Sira Certification ServiceUnit 6, Hawarden Industrial Park,Hawarden, CH53US, United Kingdom
Form 9530 Issue 1Tel:Fax:Email:Web:
+44 (0) 1244670900+44 (0) [email protected]