1
www.hunterindustries.com/ICV ICV IS ONE VALVE READY TO TAKE ON ANY COMMERCIAL HIGH - PRESSURE SYSTEM. FEATURES • Application: Commercial/municipal • Sizes: 1", 1 1 2", 2", 3" • External and internal manual bleed allows quick and easy “at the valve” activation • Glass-filled nylon construction resulting in the highest pressure rating • Double-beaded diaphragm seal design for superior leak-free performance • Fabric reinforced EPDM diaphragm and EPDM seat ensure superior performance in all conditions DC latching solenoids enable Hunter’s battery-powered controllers • Captive bonnet bolts provide hassle-free valve maintenance • Low flow capability allows use Hunter’s micro-irrigation products • Encapsulated 24 VAC solenoid with captive plunger for hassle-free service • Temperature rating: 150° F • Warranty period: 5 years ADVANCED FEATURES •• Flow control •• Filter Sentry™ •• Reclaimed water ID handle •• Accu-Sync™ capable OPERATING SPECS 1" Flow rate: 0.1 to 40 GPM 1 1 2" Flow rate: 20 to 135 GPM 2" Flow rate: 40 to 150 GPM 3" Flow rate: 150 to 300 GPM Recommended pressure range: 20 to 220 PSI FACTORY INSTALLED OPTIONS Valve without solenoid DC latching solenoid Filter Sentry USER INSTALLED OPTIONS Solenoid conduit cover (P/N 464322) DC latching solenoid (P/N 458200) Accu-Sync pressure regulator Reclaimed water ID for ICV101, 151, and 201 (P/N 561205) and 301 (P/N 515005) ICV-101G: 5" H x 3" L x 4" W ICV-151G: 7 1 8" H x 6 7 8" L x 5" W ICV-201G: 7 1 8" H x 6 7 8" L x 5" W ICV-301: 10" H x 9" L x 7 3 8" W MODELS INLET/OUTLET OPTIONS FACTORY INSTALLED OPTIONS USER INSTALLED ICV-101G = 1" globe valve (blank) = B = NPT threads BSP threads (blank) = FS = DC = LS = No option Filter Sentry DC latching solenoid Valve without solenoid (blank) = R = CC = DC = AS-ADJ = AS-20 = AS-30 = AS-40 = AS-50 = AS-70 = No option Reclaimed water ID tag Solenoid conduit cover DC latching solenoid Accu-Sync adjustable pressure regulator Accu-Sync 20 PSI pressure regulator Accu-Sync 30 PSI pressure regulator Accu-Sync 40 PSI pressure regulator Accu-Sync 50 PSI pressure regulator Accu-Sync 70 PSI pressure regulator ICV-151G = 1½" globe valve ICV-201G = 2" globe valve ICV-301 = 3" globe/angle valve EXAMPLES ICV-101G 1" globe valve, NPT threads ICV-151G - FS - R " globe valve, NPT threads, Filter Sentry, and reclaimed water ID tag ICV Pressure Loss in PSI GPM 1" 1 1 /2" 2" 3" Globe Angle 0.1 2 0.5 2 1 2 5 2.5 10 3 15 3 20 3 1.5 30 4 1.5 ICV Pressure Loss in PSI GPM 1" 1 1 /2" 2" 3" Globe Angle 40 7 1.7 0.8 50 2.2 1.2 60 3 1.7 75 3.9 2.4 90 5.5 3.2 100 7 4.2 120 10.9 6.5 135 12.7 7.9 ICV Pressure Loss in PSI GPM 1" 1 1 /2" 2" 3" Globe Angle 150 16.2 9.8 2.5 1.9 175 13.3 3 2.4 200 17.7 4.1 3.3 225 5.3 4.3 250 6.7 5.5 275 8.3 6.9 300 10.1 8.5 Charts based on full-open flow control position ICV APPLICATION SIZES FLOW RATE Commercial/Municipal 1", 1 1 2", 2", 3" 0.1 to 300 GPM

Upload: others

Post on 22-Sep-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ICV Commercial/Municipal 1, 1 APPLICATION SIZES FLOW RATE ... · ICV-151G = 1½ " globe valve ICV-201G = 2" globe valve ICV-301 = 3" globe/angle valve EXAMPLES ICV-101G 1" globe valve,

www.hunterindustries.com/ICV

ICV IS ONE VALVE READY TO TAKE ON ANY COMMERCIAL HIGH-PRESSURE SYSTEM.

FEATURES• Application:Commercial/municipal• Sizes:1",11⁄2",2",3"• Externalandinternalmanualbleedallows

quickandeasy“atthevalve”activation• Glass-fillednylonconstructionresulting

inthehighestpressurerating• Double-beadeddiaphragmsealdesign

forsuperiorleak-freeperformance• FabricreinforcedEPDMdiaphragmand

EPDMseatensuresuperiorperformanceinallconditions

• DC latching solenoids enable Hunter’s battery-powered controllers

• Captivebonnetboltsprovidehassle-freevalvemaintenance

• LowflowcapabilityallowsuseHunter’smicro-irrigationproducts

• Encapsulated24VACsolenoidwithcaptiveplungerforhassle-freeservice

• Temperaturerating:150°F• Warrantyperiod:5years

ADVANCED FEATURES••Flowcontrol••FilterSentry™

••ReclaimedwaterIDhandle ••Accu-Sync™capable

OPERATING SPECS1"Flowrate:0.1to40GPM11⁄2"Flowrate:20to135GPM2"Flowrate:40to150GPM3"Flowrate:150to300GPMRecommendedpressurerange:20to220PSI

FACTORY INSTALLED OPTIONSValvewithoutsolenoidDClatchingsolenoid

FilterSentry

USER INSTALLED OPTIONSSolenoidconduitcover(P/N464322)DClatchingsolenoid(P/N458200)Accu-SyncpressureregulatorReclaimedwaterIDforICV101,151,and 201(P/N561205)and301(P/N515005)

ICV-101G: 51/2" H x 33/4" L x 4" W

ICV-151G: 71⁄8" H x 67⁄8" L x 51/2" W

ICV-201G: 71⁄8" H x 67⁄8" L x 51/2" W

ICV-301: 103/4" H x 91/4" L x 73⁄8" W

MODELS INLET/OUTLET OPTIONS FACTORY INSTALLED OPTIONS USER INSTALLED

ICV-101G = 1" globe valve (blank) = B =

NPT threadsBSP threads

(blank) = FS =

DC =LS =

No optionFilter SentryDC latching solenoidValve without solenoid

(blank) = R =

CC =DC =

AS-ADJ =AS-20 =AS-30 =AS-40 =AS-50 =AS-70 =

No optionReclaimed water ID tagSolenoid conduit coverDC latching solenoidAccu-Sync adjustable pressure regulator Accu-Sync 20 PSI pressure regulator Accu-Sync 30 PSI pressure regulator Accu-Sync 40 PSI pressure regulator Accu-Sync 50 PSI pressure regulator Accu-Sync 70 PSI pressure regulator

ICV-151G = 1½ " globe valve

ICV-201G = 2" globe valve

ICV-301 = 3" globe/angle valve

EXAMPLES

ICV-101G 1" globe valve, NPT threads

ICV-151G - FS - R 1½ " globe valve, NPT threads, Filter Sentry, and reclaimed water ID tag

ICV Pressure Loss in PSI

GPM 1" 11⁄2" 2"3"

Globe Angle0.1 20.5 21 25 2.5

10 315 320 3 1.530 4 1.5

ICV Pressure Loss in PSI

GPM 1" 11⁄2" 2"3"

Globe Angle40 7 1.7 0.850 2.2 1.260 3 1.775 3.9 2.490 5.5 3.2100 7 4.2120 10.9 6.5135 12.7 7.9

ICV Pressure Loss in PSI

GPM 1" 11⁄2" 2"3"

Globe Angle150 16.2 9.8 2.5 1.9175 13.3 3 2.4200 17.7 4.1 3.3225 5.3 4.3250 6.7 5.5275 8.3 6.9300 10.1 8.5Charts based on full-open fl ow control position

ICV APPLICATION SIZES FLOW RATE

Commercial/Municipal 1", 11⁄2", 2", 3" 0.1 to 300 GPM