ichroma prospekt
DESCRIPTION
Equipo de pruebas especiales por flujo lateral, necesita chip de calibración para cada pruebaTRANSCRIPT
-
The next generation portable diagnostics system: Over 20 parameters available!
Immunofluorescence Assay System
www.boditech.co.kr
-
Accurate & Fast Reliable quantitative results in 3-15 min.
Quantitative test results on the spot
provides quantitative test
results in 3-15 minutes. It enables
clinicians and lab technicians to run
an individual test without mandating
additional visits by patients.
Specification: i-CHROMA
Dimensions: 250 x 185 x 80 mm
Weight: 1.2 kgs
Power adaptor: 12V DC., 3A
Display: LCD (16 x 4 character)
Interface: RS232 (Serial port)
Key pads: 5 function keys
LIS/HIS connection via PC
Thermal printer (optional)
Easy calibration with a micro-chip
Specification: i-CHROMA DUO
Dimensions: 431.5 x 340 x 180 mm
Weight: 3.7 kgs
Power: 100-240V AC, 50/60Hz, 3A
Built-in Computer with a Touch Screen
- Window XP / Intel Atom N270 CPU
- 7 LCD Display with a Touch Screen
Direct connection to LIS/HIS
Barcode scanner included
A Single channel
is an immunofluorescence-
based diagnostics system to screen
major life-style related diseases such as
cardiac diseases, cancers, diabetes,
infection. diseases and hormonal disor-
ders.
Go to www.boditech.co.kr for more information. Contact us: [email protected]
Easy to Use With built-in calibration
Versatile & AffordableOver 20 parameter available
TM TM
-
Tn-I
CK-MB
D-Dimer
Myoglobin
hsCRP
PSA
AFP
CEA
iFOB
HbA1c
Microalbumin
TSH
T4
FSH
hCG
Total HCG
LH
Prolactin
Testosterone
Cortisol
CRP
PCT
RF IgM
Ferritin
Myocardial infarction
Myocardial infarction
Heart Failure
Myocardial infarction
Cardiovascular inflammation
Prostate cancer
Liver cancer
Coloerctal cancer
Coloerctal cancer
Diabetes mellitus
Diabetes mellitus
Thyroid function
Thyroid function
Menopause
Pregnancy
Fertility
Ovulation
Sexual disorder & infertility
Sexual disorder
Metabolism
Inflammation
Sepsis
Rheumatoid Arthritis
Anemia
Serum, Plasma
Serum, Plasma
Feces (stool)
Whole blood
Urine
12 min.
12 min.
12 min.
12 min.
3 min.
15 min.
15 min.
12 min.
10 min.
12 min.
12 min.
10 min.
15 min.
15 min.
15 min.
10 min.
12 min.
10 min.
3 min.
12 min.
5 min.
10 min.
Cardiac
Note : Self-testing products of the items above are available for HbA1c, hCG, iFOB, CRP, PSA and MAU(Microalbuminuria) in some countries.
All the products are Quantitative tests and All CE-marked.
Cancer
Diabetes
Hormone
Infection
Rheumatoid Arthritis
Others
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Product class Diseases Sample type Reaction time Measurement rangesTest item
Test Markers
Boditech Med, Inc.1144-2 Geoduri, Dongnae-myeon, Chuncheon-siGwangwon-do, Republic of Korea 200-883TEL: +82-33-243-1400FAX: +82-33-243-9373E-mail: [email protected]: www.boditech.co.kr
Local Distributor
15 min.12 min.
15 min.15 min.
3~100 ng/mL
50~10,000 ng/mL
5~500 ng/mL
0.1~10 mg/L
5~350 ng/mL
1~500 ng/mL
25~1,000 ng/mL
4~15 %
2~300 mg/L
20~300 nmol/L
3~100 mlU/mL
250~200,000 mlU/mL
5~100 mlU/mL
1~100 ng/mL
1-10 ng/mL
80~800 nmol/L
2.5~300 mg/L
0.25-100 ng/mL
10~200 lU/mL
10~1,000 ng/mL
0.5~100 ng/mL0.1~100 ng/mL
1.0~50 ng/mL0.1~50 ng/mL
0.1~100 lU/mL1~100 lU/mL
2~3,000 mlU/mL2~20,000 mlU/mL
Whole bloodSerum, Plasma
Whole bloodSerum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
Serum, Plasma
-
Company At a Glance
Boditech Med, Inc. was founded by Dr. Eui Yul Choi, an entrepreneur scientist whose mission is to make
diagnostics affordable and accessible to everyone and help them lead a happy and healthy life. Since the
inception of the company in 1998, it has expanded its business in over 80 different countries with two main
products: i-CHROMMand .
With our innovative technology, we have achieved No. 1 position in China on a single reagent basis since
2011. And, we have just formed partnership with a top healthcare company in India and will continue its
fast growth over the next decades. Boditech Med, Inc. aims to become a World Top 10 POCT diagnostic
company in 2014. To do so, we will make incessant efforts to offer innovative and affordable products
including i-CHROMATSMA , a semi-automatic analyzer in 2013 and more disease markers in the global
market. Thank you.
Optical sensor
PhotoSensor
HQs, Boditech Med, Inc.South Korea
ichroma is a portable diagnostics system using fluorescence immunoassay that quantifies analytes with
a high sensitivity by measuring laser-induced epifluorescence of test strips. i-CHROMA technology utilizes
a lateral flow-type assay method in which the immune complex in analytes is captured while migrating
through the nitrocellulose membrane.
The system consists of fluorescence readers and test cartfidges. It can be used to screen life-style related
diseases from cardiac diseases, cancers, diabetes, infectious diseases to hormonal disorder. Our continu-
ous efforts with product innovation enabled us to introduce the worlds first TSH and hCG diagnostic mark-
ers using whole blood in 2012. All of i-CHROMA test markers are CE-certified. And, i-CHROMA reader and
CRP are FDA approved.
Technology
-
Semi-automatic analyzerDimensions: 210 x 303 x 395 mmWeight: 4.2 kgsData storage: 1,000 testsDisplay: 7 inch LCDInterface: RS232, LAN, USBBarcode scanner, keyboard, touch screen Built-in printer
Specification
Go to www.boditech.co.kr for more information. Contact us: [email protected]
Expected market release in 2013
A Semi-automatic analyzer coming soon
-
Immunological assaySample volume: 5 lPre-incubation time: 5~30 min.Reaction time: 12 minutesMeasurement range: 4~15 %Display: % of HbA1c & Hemoglobin concentrationNGSP certificate obtained
Description: New HbA1c test
WHO and reputable international research institutes have recently considered hemoglobin concentrationas one of the important factors in interpreting HbA1c values more accurately.
HbA1c + Hemoglobin Concentration with a Single Test
Enhanced Reliability & Reproducibility with
New HbA1c Test
Decreased erythropoiesis (Anemia)Iron deficiencyB12 deficiency
Use of iron, B12 erythropoietinReticulocytosisChronic liver disease
Increased HbA1c Decreased HbA1c
Go to www.boditech.co.kr for more information. Contact us: [email protected]
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
0.00.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0
y = 0.9939x + 0.0038R2 = 0.9835N = 150
HbA1c(%)
Toso
h G
7 HPL
C H
bA1c
(%)
is a thermostatic attachment to -CHRO
MATM designed for HbA1c test.
pre-conditions HbA1c test strips for
MATM and test results become more
accurate and reliable.
HbA1c vs Tosoh G7
-
The previous i-Chroma hCG marker is now divided into two types: hCG test for pregnancy detection
and Total -hCG for fertility testing.
For hCG values over 20,000 mIU/ml, dilution is no longer needed. Thus, tests are more
user-friendly.
Whole blood type of hCG for self-testing is also available with a different measurement range from
hCG of serum and plasma type.
REV. 23_2013_04_19
Address : 1144-2 Geoduri, Dongnae-myeon, Chuncheon-si, Gangwon-do, 200-883, Republic of KoreaTEL: 82-33-243-1400 FAX: 82-33-243-9373 Email: sales@boditech. co.kr Website : www.boditech.co.kr
Boditech Med, Inc.
hCG & Total -hCG
Highlights of Changes
Ranges of i-chromahCG values during pregnancy
0 5 10 50 100 500 1,000 5,000 10,000 50,000 100,000 200,000
hCG self-testing
2-3 week
3-4 week
4-5 week
5-6 week
6-8 week
8-12 week
Fertility testing(hCG monitoring)
hCG PRO
Total -hCG PRO
Pregnancy testing
0.2-2 week
hCG self-testing Pregnancy self-testing Whole blood 15 min. 2~20,000
Test item Intended use Sample type Reaction(Time)Measurement range
(mIU/mL)
Type of i-chroma hCG and Total -hCG
15 min.Fertility test forProfessional useTotal -hCG PRO Serum / Plasma 250~200,000
15 min.Pregnancy test for professional usehCG PRO Serum / Plasma 2~3,000
-
46
8
10
12
14
16
18
20
he
mo
chro
ma
PLU
S [g
/dL]
The dual dosing ports are patent-pending!
Specification
4 6 8 10 12 14 16 18 20
Sysmex [g/dL]
y=1.0211x-0.2383 (n=223)R =0.983CV :