Page 1: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

IBIS MEDICAL EQUIPMENTS & SYSTEMS PVT, LTD.

IBIS – Company Profile Committed To Next Generation

IBIS Medical Equipments & Systems Pvt, Ltd. 1st Floor, Excel Dream Home Building, Kachapally Road, Nambickodath Lane, Vytilla (p.o), Ernakulam – 19 Email : [email protected] Web : http://www.ibismedical.net

Page 2: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice
Page 3: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Company Profile

About IBIS Medical

Ibis Medical Equipments and Systems Pvt. Ltd is an emerging venture in the fast growing

healthcare segment. Ibis Medical was located in Ernakulam, Kerala, India. Ibis Medical

specializes in manufacturing comprehensive range of high quality Neonatal Intensive Care

Equipment. Ibis Medical is always committed to the next generation. So, the main focus of the

company is to provide international standard products, innovative healthcare solutions and

Medical Equipments for NICU. Ibis Medical is started by Mr.Sujith S in the year 2008.Team

comprises of group of biomedical engineers with deep knowledge in the field. Everyone in the

team is handpicked for their technical skills, personality and motivation. The Company trains

them to be positive and always willing to go out of the box to give solutions for customer

requirements. Ibis Medical was serving all over the country mainly focusing Kerala state, so far.

From, this year onwards Ibis Medical was ready to serve all over the world. The company

products are highly recommended by the experts in Health Care segment.

Mission

Our sole aim is to develop efficient systems for our customers involved in Medical science

through the provision of innovative solutions improved by extensive research and expert advice.

By following our mission we have to bring the finest technology products and services to India.

Vision

To be the most trusted brand in Medical Equipment industry, to be the preferred employer in

the industry and to be a catalyst for growth and excellence of the Health care business in India.

Our company philosophy has always focused on customer satisfaction with uncompromising

integrity. Ibis Medical carries products and services with the finest value and quality in the

market. To meet our customer's expectations, we ensure that our sales people and customer

service representatives generate enthusiasm and respond with extra efforts in addressing our

Page 4: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

customer's needs. Our people are trained to be open and honest with you. We are always looking

for new and better ways to improve our business relationships. With our continued success and

hard work, our vision has become reality.

Management

Office Locations

Our Corporate office is located in Ernakulam, Kerala. Our products are sold through dealers.

There are 4 dealers in kerala state. And one in Tamil Nadu and Karanataka.

Certification

We are in the final stage of ISO 9001:2008 certification. And We did study in CUSAT,

Kerala.

Mr. Sujith

MD

Mrs. Anitha

Finance Manager

Mr. Dinesh Babu

Marketing Manager

Mr.Srijith

Production

Page 5: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Neonatal Jaundice

Neonatal jaundice is a yellowing of the skin and other tissues of a newborn infant. A

bilirubin level of more than 85 umol/l (5 mg/dL) manifests clinical jaundice in neonates whereas

in adults a level of 34 umol/l (2 mg/dL) would look icteric. In newborns jaundice is detected by

blanching the skin with digital pressure so that it reveals underlying skin and subcutaneous

tissue. Jaundice newborns have an apparent icteric sclera, and yellowing of the face, extending

down onto the chest. This condition is common in upwards of 80% of newborns.

In neonates the dermal icterus is first noted in the face and as the bilirubin level rises proceeds

caudal to the trunk and then to the extremities.

Normally, about 1% of our red blood cells retire every day, to be replaced by fresh red blood

cells. The old ones are processed in the Liver and disposed in the form of billirubin and the

billirubin will leaves

The body through stool or urine. In the case of premature baby the liver may not matured for

process the Bilirubin and the Bilirubin content in the blood will increase more than 2 mg/dl and

causes Jaundice

Causes

1. Increase bilirubin load on liver cells:

Increased red blood cell (RBC) volume

Increased labeled bilirubin

Increased circulation of bilirubin in the liver

Decreased RBC survival

2. Defective hepatic uptake of bilirubin from blood plasma:

Page 6: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Decreased ligadin (Y protein)

Increased binding of Y proteins by other anions

Decreased liver uptake especially in phase two

3. Defective billirubin conjugation:

Decreased UDPG activity

4. Defective bilirubin excretion

Phototherapy

Phototherapy is the conventional and easy way of treatment for jaundice, a common

condition in newborn infants caused by high levels of seric bilirubin, which may cause chronic

bilirubin encephalopathy (kernicterus). Phototherapy treatments decrease the bilirubin levels in

the blood by changing the trans-bilirubin into cis-bilirubin isomer, which is water-soluble.

Phototherapy exposure blue light ( 420- 470 nm ) causes photoisomerization of billirubin

deposited at the skin surface, and conversion to a structural isomer called lumirubin. Lumirubin

is rapidly excreted in the bile

AAP Guildelines for Phototherapy

Light Wavelength - 420 – 470 nm ( Blue Light )

Spectral Irradiance - >30mW/cm2/nm ( Intensity )

Light Surface Area - Should cover Max BSA ( Approx 60 X 30 cm)

Page 7: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Different Phototherapy Treatments

There are different methods of phototherapy treatment for neonatal jaundice. They are

Blue Tube Phototherapy

Blue CFL Phototherapy

Halogen photherapy

LED Phototherapy

Blue Tube Phototherapy

In conventional phototherapy specially made blue tube ( Philips TL /52 .20 W) are using as

the blue light source. In this method Four blue tube from top side and four blue tube from the

bottom side are using for get max light intensity , Two white tubes are attached in each side for

observation application.

Disadvantages of Blue tube Phototherapy

Low Irriadance – 10 to 12mW/cm²/nm

Its emit wide band wavelength , so It emits Ultra violet and Infra red content along with

blue light

Ultra violet rays Causes Skin rashes In Newborns

Infra red causes possibility of Hyperthermia in baby and it causes fluid losses .

360o viewing angle of blue tube causes headache in nursing staff and care takers

Bulb life – 2000 Hrs , bulb cost

Large size of the unit

Power consumption

CFL Phototherapy

CFL Phototherapy is a second generation phototherapy device .

The only advantage they offered is its compact size compare to conventional method

CFL also producing wide band including ultraviolet and Infra red along with Blue light

Low irriadiance – 18 to 24mW/cm²/nm

Page 8: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Halogen Phototherapy

It’s a rarely using method , Spot halogen lamps are using as light source.

Hyperthermia is the disadvantage of Halogen Phototherapy

LED Phototherapy

Phototherapy is the most effective treatment when the light used is around 450nm of the

light spectrum wavelength, which corresponds to the blue color. LEDs provide light precisely at

this wavelength and have an abrupt attenuation of the irradiance from the infra-red and ultra-

violet wavelength ranges, reducing undesired effects to the infant's skin. The radiance levels are

higher, which decreases treatment time considerably. Also, the power consumption and the

heating caused by the LEDs are very low when compared with other sources of light.

About Products

The company is manufacturing the comprehensive range of high quality Neonatal Intensive

Care Equipments, they are

I Rex LED Phototherapy

I Rex 10 LED Phototherapy

I Core Radiant Warmer

I Core 10 Radiant Warmer

Wall Mount Warmer

Page 9: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

I Rex LED Phototheraphy

I Rex LED Phototherapy is truly a next generation phototherapy unit. This machine is

unique and innovative compared to all other machines. I Rex LED Phototherapy machine has

unique 4 modes of operation, which makes more user-friendly in operating. The four modes of

the operation are

Swift Mode - It is a preset mode with 35 mW at 30 cm distance , ideal for patient

having more than 15 mg/dl.

Recovery Mode - It is also preset mode with 15 mW, it will be useful for patients who

required low intensity. It is called Advanced Phototheraphy, that is

baby with 5mg/dl can take Phototheraphy treatment in this mode

Auto Mode - User can set the treatment time. In between if the mother taking the

baby for feeding means, they can switch off the machine, and when

they are again switch it on, it will start from the time they stopped.

After time, it will automatically switch to recovery mode.

User Mode - In this mode user can set mW, as per their requirements

And other features of I Rex LED Phototherapy are

It meets the AAP Guidelines

Low Power Consumption (30 W)

24 LED’s are used

Bulb life is 20,000 hrs

Compact size and Weightless

It covers 60 * 30 surface area

Page 10: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Light Wavelength 450 -470 nm (peak at 458nm)

More safe and User-friendly in operating

Doesn’t emit UV or IR

One year warranty

I Rex 10 LED Phototheraphy

I Rex 10 LED Phototherapy is similar as I Rex LED Phototherapy, but it has only one mode

operation. Only Swift mode will be available in I Rex 10. Those who in need of only swift mode,

I Rex 10 LED Phototherapy is best product. And also, it is very low cost.

I Core Radiant Warmer

I Core Radiant Warmer is a break through in infant warming. I core is designed to fullfill the

present and future requirements of a radiant warmer. Machine has a unique Multi level Safety

Systems. It Provide a extra safety Sensor for monitoring the ambient temperature of the bed area.

It will switch off the machine when the temperature exceeds 39 Degree Celsius( editable ).

I Core Radiant Warmer has 4 modes of operations, they are

Pre Warm Mode (Alarm Free)

Manual Mode

Servo Skin Mode

Servo Air Mode

Other Advantages are

Large Display

Apgar Timer

Tiltable Bed

High Safety

Page 11: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

User Friendly

I Core 10 Radiant Warmer

I Core 10 Radiant Warmer is same as I Core Radiant Warmer, except the four modes of

operation. It has only one mode of operation (Servo Skin Mode). It is very low cost with high

quality.

Wall Mount Warmer

Wall mount warmer is also similar to I Core, only difference is that it can be fixed in the

wall. It has high quality with low cost.

Page 12: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

User’s List

Partial User's LIST - LED Phototherapy ( Model - I REX )

Sl

No Customer

Number of

Units Doctor Name Phone Number

1 KIMS Hospital , Thiruvanthapuram 7 Nos Dr. Naveen Jain 0471 4071000 , 2447575

AIMS Cochin 4 Nos Dr. Sasidaran

2 Indus Westside hospital , banglore 5 Nos 080 28488181

3 JSS Medical College ,Mysore 5 Nos

4 Kaveri Medical College,Bangalore 2Nos

4 Malabar Medical College , Kozhikode 2 Nos

5 SBM Hospital, Karunagappally 2Nos Dr.Bidhu Pillai 9846019430

6 Jose Giri Hospital , Thalaserry 2 Nos Dr.Deepa 9495655081

7 CRAFT Hospital, Kodungallor 1 No Dr. Majeed 9745522499

8 Amala Medical College , Thrissur 1 No Dr. Sreenivasan 0487 2304000

9 Aswini Hospital , Thrissur 1 No Dr. Aloke 0487 2335754

10 E.M.S Hospital , Perinthalmanna 1 No Dr . Ramdas 04933 225751

11 Bharath Hospital , Kottayam 1 No Dr. Anoop 0481 2582947

12 Sai Nursing Home , Palakkad 1 No Dr. Prathiba Prakash 04923263489

13 LISA Hospital , Kozhikode 1 No

14 K. M. C Hospital , Manippal 1 No Dr . Lessley 08202571210

15 S.K.P Hospital , Mavelikkara 1 No 0479 2302764

16 Saroja nursing Home, Thrissur 1 No

Dr.

Samgameswaran 04872335210

17 Chandramadhi amma hospital , Thrissur 1 No Dr. Ajitha. S.Menon 04872361420

18 Gourisa Hospital , Thiruvanthapuram 1 No Dr. Prema

19 BCMC Hospital, Mala 1 No

20 Deen Hospital, Punalur 1 No

21 Anupama Hospital, Balaramapuram 1 No Dr. Jayanthi 94447311047

22 St. Joseph Hospital, Manjummel 1 No

23 Chithra Hospital , Panthalam 2Nos

24 Relief Hospital, 1 No

25 Padma Hospital, 1No

Page 13: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Feedback’s

Kerala Institute of Medical Science ( KIMS)

“Ibis finally achieved India’s solution for phototherapy with affordable and reliable technology”

DR Naveen Jain

HOD ,Department of Neonatology

Kerala Institute of Medical Science ( KIMS)

Thiruvanthapuram

Dr. Abdul Majeed

“I am very happy with the new IBIS LED phototherapy unit. I find it very easy to give

unsupervised phototherapy for the babies who is with the mother. LED phototherapy won’t

produce much heat so that we don’t have to monitor the babies as much as the babies with

conventional units”

Dr.Abdul Majeed

Consultant Neonatologist

CRAFT Hospital & Research Centre,

Kodungallur, Thrissur

Kasturba Medical College (KMC) , Manipal

Compared to conventional phototherapy IREX LED Phototherapy is more effective and Its free

from the side effects”

Dr Leslie Edward S Lewis

Head .Neonatology Intensensive care Unit

Page 14: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

Kasturba Medical College (KMC) , Manipal

Dr. Bidhu

"Finally the dream of an ideal LED phototherapy become a reality through IBIS.This is the best

LED phototherapy system I have used so far with good effect.I would definitely recommend this

system to others."

Dr.Bidhu

Consultant Neonatologist

S B M Hospital

Karunagappally

Dr. Sreenivasan

“I REX LED Phototherapy unit giving good result , very efficient and safe with low power

consumption”

Dr Sreenivasan

Consultant Neonatolgist

Amala Medical College Hospital

Thrissur

Dr. Ajitha

“I REX LED Phototherapy system is more convenient and giving Quick result without any side

effects”

Dr Ajitha

Consultant Neonatologist

Page 15: IBIS – Company Profile2.imimg.com/data2/GX/LQ/MY-/company-profile.pdf · Finance Manager Mr. Dinesh Babu Marketing Manager Mr.Srijith Production . Neonatal Jaundice Neonatal jaundice

CAM Hospital

Thrissur

Dr. Sajan Thomas

“I am Happy with the performance of I REX LED Phototherapy unit manufactured by M/s IBIS

Medical Equipment & Systems Pvt Ltd “

Dr Sajan Thomas

Consultant Neonatologist

Caritas Hospital

Kottayam

Dr. Parimala

“I REX is a good machine , Not giving much complaint compared to conventional Phototherapy

, ideal for the treatment of New born Jaundice”

Dr Parimala

HOD , Neonatolgy Department

Cauvery Medical Centre

Bangalore

Dr. George

“This LED Phototherapy is probably the best one that I Have come across , Low Cost , free from

side effects and finally baby friendly”

Dr George

Consultant Neonatolgist

S H Medical Centre