i page doublelok ultradek roof-ls-36 wall r '14 r•02€¦ · doublelok i ultradek roof-ls-36...

14
Page DoubleLok I UltraDek Roof- LS-36 Wall DLI06105 Standard and Standard Large Rake Trim- Low, High or Hi-Thermal Clip oA r '14 R•02 Wall Panel Thickness 1t 2" 3" 4" Rake Slirl .. F215 Fastener #4A i-14 x a" SD W/Washer 1'-0 o.c Insulated Concealed Fastener Wall Panel Panel Thickness Standard/ Std Large/ Northern Northern Lrg Rake Trim Rake Trim F3969 F3886 F3970 F3887 F3971 F3888 F3972 F3889 F3973 F3890 Tri-Bead Tape Sealer HW504 Fastener #1 E ;l-14 x 1!" LL SD W/Washer at 2'-0 O.C. Loose Fill Insulation or Field Applied Foam (Not by Metal Bldg. Mfr.) Support HW7710 (Low) HW7720 (High) HW7664 (Hi- Thermal DL -Only) Fastener #5 1--14 X 1!" at 24" O.C. Non-Skinning Butyl Tube (Vapor Sealant) IMP71 00 il" Bead See ICF0300_ for Panel Clip Application Rake Angle RA1 L 4" x 2" x 16 Ga. w/Fastener #12A 12 X 1" P.H. at each Purlin Outside Closure HW456 Flat Tape Sealer IMP7300 1'' X

Upload: vuphuc

Post on 09-Apr-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page

DoubleLok I UltraDek Roof- LS-36 Wall DLI06105 Standard and Standard Large Rake Trim- Low, High or Hi-Thermal Clip oA r '14 R•02

Wall Panel Thickness

1t 2"

2~"

3"

4"

Rake Slirl .. -~

F215 Fastener #4A

i-14 x a" SD W/Washer

1'-0 o.c Insulated

Concealed Fastener Wall Panel

Panel Thickness

Standard/ Std Large/ Northern Northern Lrg

Rake Trim Rake Trim F3969 F3886

F3970 F3887

F3971 F3888

F3972 F3889

F3973 F3890

Tri-Bead Tape Sealer HW504

Fastener #1 E ;l-14 x 1!" LL SD W/Washer at 2'-0 O.C.

Loose Fill Insulation or Field Applied Foam (Not by Metal Bldg. Mfr.)

/""I~"~"' Support HW7710 (Low) HW7720 (High) HW7664 (Hi-Thermal DL -Only)

Fastener #5 1--14 X 1!" at 24" O.C.

Non-Skinning Butyl Tube (Vapor Sealant) IMP71 00 il" Bead

See ICF0300_ for Panel Clip Application

Rake Angle RA1 L 4" x 2" x 16 Ga. w/Fastener #12A 12 X 1" P.H. at each Purlin

Outside Closure HW456

Flat Tape Sealer IMP7300 1'' X a~~

Doublelok I UltraDek Roof- Horizontal Insulated Concealed Fastener Wall Panel Roof Termination At Rake- Low, High Or Hi-Thermal Clip

Page DLI06203

Date Rev May '14 00

Termination Trim F117 (Field Cut to Length

When Req'd.)

Fastener #1E H4 X 1i" LL SD

W/Washer At 2'-0" O.C.

Fastener #4 i-14 x ·~: LL SD

W/Washer At 6" O.C.

Tri-Bead Sealant ,t· X r HW504

Rake Trim (See Chart) --­Rake Support Angle

HW7710 - Low HW7720 - High

HW7664 - Hi-Thermal (DoubleLok Only)

Loose Fill Insulation Or Field Applied Foam

(Not By Metal Bldg. Mfr.)

Thru Panel Flat Head SD W/0 Washer At Each

Vertical Support Location And At 2' -0" O.C. Max.

Between Supports

Rake Slide Trim F215

Fastener #4 i-14 x r LL SD W/Washer

At 8" O.C.

Insulated Horizontal Concealed ----1 Fastener Wall Panel

(Field Cut As Req'd.)

Panel I I Thickness"' "'

4" To 6"

1"

Urethane Sealant HW54_ Continuous f Bead

Rake Angle RA1 L2" x 4" x 16 Ga.

Tri-Bead Sealant ,t" X r HW504 Fastener #1 E H4 X 1!" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i-14 x 1i" Shoulder SD W/0 Washer At 2'-o· O.C.

Rake Support Angle HW7710 - Low HW7720 - High HW7664 - Hi-Thermal (DoubleLok Only)

Rake Angle RA1 L2" x 4" x 16 Ga.

Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Zee Purlin

Wall Standard Standard Panel Rake Trim Lar'lf

Thickness Rake rim

2" F3950 F3880

2 1/2" F3951 F3881

3" F3952 F3882

4" F3953 F3883

5" F3954 F3884

6" F3955 F3885

DoubleLok I UltraDek Roof- Horizontal Insulated Concealed Fastener Wall Panel Standard And Standard Large Rake Trim- Low, High Or Hi-Thermal Clip

Tri-Bead Sealant N!" x ~" ----.... HW504

Rake Trim (See Chart) -~ r--:--:::7"i

Rake Support Angle HW7710 - Low

HW7720 - High HW7664 - Hi-Thermal

(DoubleLok Only) Loose Fill Insulation

Or Field Applied Foam (Not By Metal Bldg. Mfr.)

Thru Panel Flat Head SD W/0 Washer At Each

Vertical Support Location And At 2' -0" O.C. Max.

Between Supports

Rake Slide Trim F215

Fastener #4 i-14 x r LL SD W/Washer

At a· o.c. Insulated Horizontal Concealed ----1

Fastener Wall Panel (Field Cut As Req'd.)

Panel I I Thickness"' "'

Fastener #1E !-14 x 1!" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i-14 x 1!" Shoulder SD W/0 Washer At 2'-0" O.C. Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Roof Panel

Urethane Sealant HW54 _ Continuous ~" Bead

Rake Angle RA 1 L2" x 4" x 16 Ga.

Zee Purlin

Wall Panel

Thickness

2"

2 1/2"

3"

4"

5"

6"

Page DLI06205

Date Rev May '14 00

Standard Standard Rake Trim Lar'lf

Rake rim

F3950 F3880

F3951 F3881

F3952 F3882

F3953 F3883

F3954 F3884

F3955 F3885

Doublelok I UltraDek Roof- Insulated Horizontal7.2 lnsui-Rib Wall Panel Roof Termination At Rake- Low, High Or Hi-Thermal Clip

Termination Trim F117 (Field Cut to Length

When Req'd.)

Fastener #1E i-14 x 1i" LL SD

W/Washer At 2'-0" D.C.

Fastener #4 H4 x r LL so

W/Washer At 6" O.C.

Tri-Bead Sealant it" x ~· HW504

Rake Trim (See Chart) Rake Support Angle

HW7710 - Low HW7720 - High

HW7664 - Hi-Thermal (DoubleLok Only)

Loose Fill Insulation Or Field Applied Foam

(Not By Metal Bldg. Mfr.)

Thru Panel Flat Head SD W/0 Washer At Each

Vertical Support Location And At 2' -o· O.C. Max.

Between Supports Rake Slide Trim F215

Fastener #4 i-14 x ~· LL SD W/Washer

At Each High Rib

Panel Closure IMP7609 With Urethane Sealant

HW54_ Each Side

Insulated Horizontal 7.2 lnsui-Rib Wall Panel

(Field Cut As Req'd.)

Panel Thickness

4" To 6"

1"

Urethane Sealant HW54_ Continuous ~" Bead

Rake Angle RA1 L2" x 4" x 16 Ga.

Page DLI06303

Date Rev May '14 00

Tri-Bead Sealant it" X r HW504 Fastener #1 E H4 X 1!" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i-14 x 1i" Shoulder SD W/0 Washer At 2'-o· O.C.

Rake Support Angle HW7710 - Low HW7720 - High HW7664 - Hi-Thermal (DoubleLok Only)

Rake Angle RA1 L2" x 4" x 16 Ga.

Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Zee Purlin

Wall Standard Standard Panel

Thickness Rake Trim Lar9f Rake rim

2 1/2" F3951 F3881

3" F3952 F3882

4" F3953 F3883

5" F3954 F3884

6" F3955 F3885

DoubleLok I UltraDek Roof- Insulated Horizontal7.2 lnsui-Rib Wall Panel Standard And Standard Large Rake Trim- Low, High Or Hi-Thermal Clip

Tri-Bead Sealant N!" x ~" -----.... HW504

Rake Trim (See Chart) - ........ ....----= Rake Support Angle --i""fJJ"Jtt~IOJ

HW7710 - Low HW7720 - High

HW7664 - Hi-Thermal (DoubleLok Only)

Loose Fill Insulation Or Field Applied Foam

(Not By Metal Bldg. Mfr.)

Thru Panel Flat Head W/0 Washer At Each

Vertical Support Location And At 2' -0" O.C. Max.

Between Supports

Rake Slide Trim F215 Fastener #4

i-14 x ~· LL SD W/Washer At Each High Rib

Panel Closure IMP7609 With Urethane Sealant

HW54_ Each Side

Insulated Horizontal 7.2 lnsui-Rib Wall Panel

(Field Cut As Req'd.)

Panel Thickness

Fastener #1E i-14 x 1i" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i--14 x 1i" Shoulder SD W/0 Washer At 2'-0" O.C. Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Roof Panel

Urethane Sealant HW54_ Continuous f Bead

Rake Angle RA 1 L2" x 4" x 16 Ga.

Zee Purlin

Wall Panel

Thickness

2 1/2"

3"

4"

5"

6"

Page DLI06305

Date Rev May '14 00

Standard Standard Rake Trim Lar9f

Rake rim

F3951 F3881

F3952 F3882

F3953 F3883

F3954 F3884

F3955 F3885

DoubleLok I UltraDek Roof- Insulated Vertical7.2 lnsui-Rib Wall Roof Termination At Rake- Low, High Or Hi-Thermal Clip

Termination Trim F117 (Field Cut to Length

When Req'd.)

Fastener #1E H4 X 1i" LL SD

W/Washer At 2'-0" O.C.

Fastener #4 i-14 x a" LL SD

W/Washer At 6" O.C.

Tri-Bead Sealant ,t" x a" HW504

Rake Trim (See Chart) Rake Support Angle

HW7710 - Low HW7720 - High

HW7664 - Hi-Thermal (DoubleLok Only)

Loose Fill Insulation Or Field Applied Foam

(Not By Metal Bldg. Mfr.) Clip Fasteners Wall Panel Clip ----lt----11

IMP4633

Rake Slide Trim F215

Fastener #4 i-14 x a" LL SD W/Washer

At Each High Rib

Panel Closure 7609 Insulated Vertical 7.2 ---o-1

lnsui-Rib Wall Panel

~ Thickness

4" To 6"

1"

Butyl Sealant IMP71 00 Continuous ~" Bead Rake Angle RA1 L2" x 4" x 16 Ga.

Page DLI06403

Date Rev May '14 00

Tri-Bead Sealant ,t" x a" HW504 Fastener #1 E H4 X 1!" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i-14 x 1i" Shoulder SD W/0 Washer At 2'-o· O.C.

Rake Support Angle HW7710 - Low HW7720 - High HW7664 - Hi-Thermal (DoubleLok Only) Roof Panel

Rake Angle RA1 L2" x 4" x 16 Ga.

Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Zee Purlin

Wall Standard Standard Panel Rake Trim Lar9f

Thickness Rake rim

2 1/2" F3951 F3881

3" F3952 F3882

4" F3953 F3883

5" F3954 F3884

6" F3955 F3885

DoubleLok I UltraDek Roof- Insulated Vertical7.2 lnsui-Rib Wall Standard And Standard Large Rake Trim- Low, High Or Hi-Thermal Clip

Tri-Bead Sealant ,i;" x ~" ---....... HW504

Rake Trim (See Chart)

Rake Support Angle HW7710 - Low

HW7720 - High HW7664 - Hi-Thermal

(DoubleLok Only) Loose Fill Insulation

Or Field Applied Foam (Not By Metal Bldg. Mfr.)

Clip Fasteners --::l__,tt::rtrr>--Wall Panel Clip -

IMP4633

Rake Slide Trim F215

Fastener #4 i-14 x ~" LL SD W/Washer

At Each High Rib

Panel Closure 7609 Insulated Vertical 7.2 ---1

lnsui-Rib Wall Panel

~ Thickness

Fastener #1E !-14 x 1!" LL SD W/Washer At 2'-0" O.C.

Fastener #5 i-14 x 1!" Shoulder SD W/0 Washer At 2'-0" O.C. Fastener #12A 12 x 1" Pancake Head SD W/0 Washer At Each Purlin

Roof Panel

Butyl Sealant IMP71 00 Continuous ~" Bead

Rake Angle RA 1 L2" x 4" x 16 Ga.

Zee Purlin

Wall Panel

Thickness

2 1/2"

3"

4"

5"

6"

Page DLI06405

Date Rev May '14 00

Standard Standard Rake Trim Lar9f

Rake rim

F3951 F3881

F3952 F3882

F3953 F3883

F3954 F3884

F3955 F3885

Page

Doublelok I UltraDek Roof· Insulated Concealed Fastener Wall Expansion Ridge End Cap Assembly

DLI06001 0

Apr ·14r·o1

Tab A (inside)

Apex-Tab B1 Tab B2

Fastener #4 f'-14 X r LL SD (12 required)

(\ \ ~~,Tb A II ---- ' ----· II. 0

1,.- __.;• \ ·~--- ~ (inside) / • ../. I '·,_~ , --·L .. 1\1 ,"' ........... =-----...... .. .. ,"' .................. .................. .. ..

Expansion Ridge ',....................... ... ....................... ~ End Cap F679

Wall Panel Thickness

2"

3"

4"

- -P eo k Box _/ ~~:::..--~~--:;::::::;::::::::..--:;::::::;::::::::::t:::::::::::;:::;:::--:::::;:::::;~--...:::;;~~J

(See chart) \-: ..... -

Expansion Ridge End Cap Assembly

1. Apply (2) runs of tube sealant along vertical and horizontal surfaces of expansion end cap.

2. Place end cap inside expansion ridge flashing, allowing the end cap to

conform to the ridge flashing profile. Do not deform the top of the ridge by exerting too much pressure.

3. Make sure tab is even with, but not resting on top of the peak box.

Tab "A" must be able to pivot in front of the peak box because of panel contraction.

4. Using a screwdriver, insert the blade in the apex of tab "B1'' and "B2",

and twist the blade enough to cause tab "B1'' to spread slightly

away from tab "B2".

5. Secure the end cap to the ridge flashing with (12) Fastener #4

f'-14 X a" LL SD W/Washer as shown.

Standard/ Std Large/ Northern Northern Lrg Peak Box Peak Box

F3640 F3653

F3642 F3655

F3644 F3657

F3646 F3659

W/Washer

Doublelok I UltraDek Roof- Insulated Concealed Fastener Wall Expansion Ridge End Cap

Peak Bax

Tri-Bead Tape Sealer HW504

Rake Trim

~ ......._ Parapet Rake ~· Cleat F292

l(jg e, Rake , Support Angle

Expansion Ridge F675

Tri-Bead Tape Sealer HW504

Parapet Rake Cleat F292 (Field cut the 15" long piece in half) Locate one piece on each side of Building Ridge. Attach each Cleat with (3)

Fastener #4 f-14 x a" LL SD W/Washer (12 req'd.)

..--~---1'-+---i,-Fastener #1E :1-14 x 1:1"

Expansion Ridge End Cap F679 Apply two runs tube sealant on Expansion Ridge End Cap before installation

Peak Box -------1 (See Chart)

Fastener #4 r-14 x a"

1--W-a-II-Pa_n_e_l -r.::S"""ta_n_d:-a-rd7 /7r:S"'t-:d-L:-a-r-ge_/,

Thickness Northern Northern Lrg

LL SD W/Washer 8" o.c.

Peak Box Peak Box

Thickness Panel I 2" F3640 F3653

F3642 F3655

3" F3644 F3657

4" F3646 F3659

LL SD W/Washer

Loose Fill Insulation or Field Applied Foam (Not by Metal Bldg. Mfr.)

Fastener #5 :1"-14 X 1:1" at 24" O.C. Rake Support Angle (See Endwell Framing) Non-Skinning Butyl Tube (Vapor Sealant) IMP71 00 ~" Bead

Rake Angle RA1 L 4" X 2" X 16 GA.

See ICF0300_ for Panel Clip Application

Flute Closure Strip IMP7607 (Fluted Panel only)

Perimeter Flashing Sealant Tape IMP7405 (Not required with Fluted wall panel)

Doublelok I UltraDek Roof· Insulated Concealed Fastener Wall Roof Termination at Rake· Low, High or Hi-Thermal Clip

-----(3) Fastener #4 ;!-14 x ~" LL SD W/Washer

_ _...__(1) Fastener #1E ---~ ;!-14 x 1i" LL SD W/Washer

r' Bead ~~~~;;;;;;><::=::--Tube Sealant

__.-..a--Termination Trim

"""'-~~~~---Tri Bead Tape Sealer

'f:~=---Rake Trim

Termination Trim Lap Detail

Panel Fin and Clip must be hand crimped before installing Termination Trim

Fastener #4 !-14 x ~· LL SD W/Washer

At 6" O.C. T ri Bead Tape Sealer HW504

Rake Trim (See Chart)

Fastener #1E---t-~:><:=~" i--14 x 1~" LL SD W/Washer At 2'-o o.c.

Loose Fill Insulation or field applied Foam

(Not by Metal Bldg Mfr.)

Wall Panel Thickness

Rake Support HW771 0 (Low)

HW7720 (High) HW7664 (Hi-Thermal

DL Only) Non-Skinning But~ Tube (Vapor Sealant) lt.1P71 00 f Bead

See ICF0300_ far Panel Clip Application

Insulated Concealed Fastener Wall Panel

Standard/ Std Large/ Northern Northern Lrg

Rake Trim Rake Trim 2"

Panel I Thickness

~-~-~---~----~ 2r' F3950 F3880

F3951 F3881

3" F3952 F3882

4" F3953 F3883

I I I I I I I I I I I I

4" to 6"

Fastener #12A 12 X 1" P.H. at each purlin

Fastener #5 r-14 x 1r at 24" O.C.

Rake Angle RA 1 L 4" x 2" x 16 Ga.

Termination Trim F117 Field Cut to width when required.

Tri Bead Tape Sealer HW504

Fastener #1 E ~-14 X 1~" LL SD W/Washer At 2'-0 O.C.

Roof Panel

Rake Support HW771 0 ~Low) HW7720 High) HW766 lf{i-Thermal DL Only) Rake Ang]e RA1 L 4" X 2" X 16 Ga. Fastener #5 ~"-14 X 1~" at 24" O.C.

Page

DoubleLok I UltraDek Roof· Insulated Concealed Fastener Wall DLI06005 Standard and Standard Large Rake Trim· Low, High or Hi-Thermal Clip Ma '14 R•02

Wall Panel Thickness

2"

3"

4"

Rake Trim (See Chart)

Rake Slide F215

Fastener #4 !"-14 X ~"

LL SD W/Washer 8" o.c

Insulated Concealed Fastener

Wall Panel I Panel .

Thickness

Standard/ Std Large/ Northern Northern Lrg

Rake Trim Rake Trim F3950 F3880

F3951 F3881

F3952 F3882

F3953 F3883

Tri-Bead Tape Sealer HW504

Fastener #1 E i-14 x 1!" LL SD W/Washer at 2'-o o.c. Loose Fill Insulation or Field Applied Foam (Not by Metal Bldg. Mfr.)

Roof Panel

Rake Support (See Endwell Framing Layout)

Fastener #12A 12 X 1" P.H. at each Purlin

Fastener #5 i"-14 X 1!" at 2'-0 O.C. Non-Skinning Butyl Tube (Vapor Sealant) IMP71 00 g" Bead

Rake Angle RA1 L 4" x 2" x 16 Ga.

See ICF0300_ for Panel Clip Application Flute Closure Strip IMP7607 (Fluted Panel only)

Perimeter Flashing Sealant Tape IMP7405 (Not required with Fluted Wall Panel)

Doublelok I UltraDek Roof· LS-36 Wall Expansion Ridge End Cap Assembly

Tab A (inside)

Apex-Tab B1 Tab B2

,,!!, ... \ ....

Page

DLI06101 Date Rev.

Apr '14 01

Fastener #4 i-14 x a· LL so ( 12 required)

W/Washer

q f'S---- \ -----">\ ~- __-Tab A [,-' ,/ \ -~--- _/ V (inside) // ••• ./, -i..... ------ "'

,' ------- ·------ ~~ ~ Expansion Ridge .......................... ... .................... .. End Cap F679 ~ - - 'J

Wall Panel Thickness

1f' 2"

2f'

3"

4"

Pegk Bgx _/ L,-_:::--_ --::::::::::--~=~t::::::::::::::::::::::::::::::::J (See chart) -

Expansion Ridge End Cap Assembly

1. Apply (2) runs of tube sealant along vertical and horizontal surfaces of expansion end cap.

2. Place end cap inside expansion ridge flashing, allowing the end cap to

conform to the ridge flashing profile. Do not deform the top of the ridge by exerting too much pressure.

3. Make sure tab is even with, but not resting on top of the peak box.

Tab "A" must be able to pivot in front of the peak box because of panel contraction.

4. Using a screwdriver, insert the blade in the apex of tab "B1" and "B2",

and twist the blade enough to cause tab "B1" to spread slightly

away from tab "B2".

5. Secure the end cap to the ridge flashing with (12) Fastener #4

i"-14 X a" LL SD W/Washer as shown.

Standard/ Std Large/ Northern Northern Lrg Peak Box Peak Box

F3669 F3666

F3670 F3683

F3672 F3685

F3674 F3687

F3676 F3689

Doublelok I UltraDek Roof· LS-36 Wall Expansion Ridge End Cap

Tri-Bead Tape Sealer HW504

Rake Trim Peak Box

Wall Panel Standard/

Thickness Northern Peak Box

1f F3669

2" F3670

2f F3672

3" F3674

4" F3676

~ ......_ Parapet Rake ""· Cleat F292

'11(jg e,

Rake ...... Support Angle

Expansion Ridge F675

Fastener #4 f'-14 x a" LL

SD W/Washer (12 req'd.)

Expansion Ridge End Cap F679 Apply twa runs tube sealant on Expansion Ridge End Cap before installation

Peak Box -------1 (See Chart)

Fastener #4A r-14 x a" SD W/Washer 1'-0 o.c.

Std Large/ Northern Lrg

Peak Box Panel F3666 Thickness F3683

F3685

F3687

F3689

I I

Tri-Bead Tape Sealer HW504

Parapet Rake Cleat F292 (Field cut the 15" long piece in half) Locate one piece on each side of Building Ridge. Attach each Cleat with (3) Fastener #1E f'-14 x 1i" LL SD W/Washer

Loose Fill Insulation or Field Applied Foam (Not by Metal Bldg. Mfr.)

Fastener #5 f'-14 X 1;f' at 24" O.C. Rake Support Angle (See Endwell Framing) Non-Skinning Butyl Tube (Vapor Sealant) IMP71 00 ~" Bead

Through Panel Fastener 12" O.C. (See LSW03001 for Piece Mark) Rake Angle RA1 L 4" x 2" x 16 Ga. Outside Closure HW456 Flat Tape Sealer IMP7300 1" x r

Doublelok I UltraDek Roof- LS-36 Wall Roof Termination at Rake- Low, High or Hi-Thermal Clip

..------(3) Fastener #4

i-14 x ~· LL SD W/Washer

---(1) Fastener #1E

i-14 x 1f LL SD W/Washer

i" Bead -"'0::::::;--.L ~;;;;;;;;;;;;;;;;>=:::::::::::-- Tube Sea I ant

__ .<}-Termination Trim

'~~;.::~--Tri Bead Tape Sealer

+-----Rake Trim

Termination Trim Lap Detail

Panel Fin and Clip must be hand crimped before installing Termination Trim

Fastener #4 i-14 x 8" LL SD W/Washer

At 6" O.C.

Tri Bead Tape Sealer HW504

Rake Trim (See Chart)

Fastener #1 E -----1-----1;.""""~ i-14 X 1i" LL

SD W/Washer At 2'-0 O.C.

Loose Fill Insulation or field applied Foam

(Not by Metal Bldg Mfr.)

Rake Support HW7710 (Low)

HW7720 (High) HW7664 (Hi-Thermal

DL-Only) Nan-Skinning But~ Tube (Vapor Sealant) IMP7100

i" Bead

Wall Panel Standard/ Std Large/ Northern Northern Lrg Thickness

Rake Trim Rake Trim

1f' F3969 F3886

2" F3970 F3887

2f' F3971 F3888

3" F3972 F3889

4" F3973 F3890

Panel Thickness

4' to 6'

Fastener /15 i" -14 X 1i" at 24' O.C.

Rake Angle RA1 L 4' x 2" x 16 Ga.

Termination Trim F117 Field Cut to width when required.

T ri Bead Tape Sealer HW504 Fastener #1E i-14 x 1i" LL SD W/Washer At 2'-o o.c. Roof Panel Field Cut

-t-<.nk" Support HW7710 (Low) HW7720 (High) HW7664 (Hi­Thermal DL-Only)

Rake An~e RA1 L 4" x 2 x 16 Ga. Fastener /15 r-14 x 1r at 24" O.C.