HYDROPHOBIC & HYDROPHILIC IOLs
C
M
Y
CM
MY
CY
CMY
K
CMY
C
M
Y
CM
MY
CY
CMY
K
CONTENTS
HYDROPHOBIC IOLs
Features of RUMEX Hydrophobic IOLs
UV&blue light blocking
Contrast sensitivity
Color vision
Natural chromophore
Negative pherical berration
Low glass transition temperature
Low chromatic aberration
Double square-edge
HYDROPHILIC IOLs
Features of RUMEX Hydrophilic IOLs
Co-aspheric optic design
Best- orrected isual cuity
UV&blue light blocking
Double square-edge
1
1
1
11
1
1
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
HYDROPHOBIC IOLs
RUMEX HYDROPHOBIC IOLs
RUMEX offers you and highest quality standards with AquaFree IOLs. The soft hydrophobic material of AquaFree Yellow IOLs possess the most important . During the manufacturing process, the lens material is tray-polymerized and then eliminating the occurrence of glistenings.
An excellent sharp edge in optic and haptics on both sides of the lens, high-quality material with less than 0,5% water content,
are the features that make RUMEX IOLs unique.
Natural yellow material with natural chromophore
Advanced ptical ngineeringSpecial surface polishing
Low transition temperatureExtreme double square edge around entire optic periphery 360° barrier helps to prevent PCO caused by cellular migrationMethod of Sterilization: Ethylene Oxide (ETO)
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
in RUMEX AquaFree Yellow IOLs the patient and diseases that can be caused by chronic exposure to blue light:
• Macular Degeneration• Eye Fatigue• Myopia• Red Eye Syndrome• Sleeping Quality
• Presbyopia
Macular Degeneration
HYDROPHOBIC IOLs
100-380nm 380-500nm
500-700nm
FEATURES OF RUMEX HYDROPHOBIC IOLs
UV&blue light blocking
RUMEX AquaFree Yellow Hydrophobic IOL provides (blue light filtering) similar to a young natural crystalline lens. It filters out harmful violet rays protecting the retina without blocking essential blue light range (from 465 nm to 495 nm) .
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
HYDROPHOBIC IOLs
Contrast sensitivity
has been studied n patients with blue-filtering RUMEX AquaFree Yellow implanted to assess the patients image quality.
Data reported for a total of 382 patients in nine different studies confirmed that there was
Color vision
was evaluated to confirm that the yellow from the blue light filtering chromophore
A total of 430 patients were evaluated. No significant difference was observed in test results for the patients with the blue-filtering IOL implanted, as compared to eyes implanted with the control UV-absorbing IOL.
Natural chromophore
possesses Chromophore
concentration of AquaFree Yellow is 0.02% which doesn't affect negatively the color perception of the patient. Natural chromophore and its lower concentration provide a
under low light condition.
In the chart you can find the visible transmission spectrum of AquaFree Yellow +20D IOL.
RUMEX Hydrophobic IOL AquaFree Yellow provides better protection of Macula.
SPECTRAL TRANSMITTANCE CURVE OF RUMEX AQUAFREE IOL
The cutoff wavelength of 10% transmission for UV light is 392 nm
20
30
40
50
60
70
80
90
100
300 400 500 600 7000
10
TRA
NSM
ITTA
NC
E (%
)
Yellow 4 years old 53 years oldWAVELENGTH (nm)
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
Negative pherical berration (SA)Intraocular l
n the human eye is a combination of the positive spherical
RUMEX offers the aspheric intraocular lens with negative spherical aberration so that it offsets all or part of positive SA of the average cornea. This ensures good contrast sensitivity and visual acuity, which is especially crucial in low-contrast environments and dim light conditions.
Figure 1. A: a lens without spherical aberration B: a lens with spherical aberration
In the young eye, the natural lens typically has negative SA and offsets the positive spherical aberration of cornea. An old patient can still have but might have difficulties in the lower contrast conditions (fog, dust). RUMEX aspheric IOL is calculated so that the residual spherical aberration in the eye is adjusted for the
Low glass transition temperature (Tg)
Glass transition temperature is a very important characteristic of the IOL material.
RUMEX IOL material offers the RUMEX IOL acrylic . Because of the very low transition temperature,the RUMEX IOL is soft and easy to inject at room temperature.
Many surgeons prefer RUMEX IOL because of its excellent material behavior. The haptic of the IOL is designed not to transmit any forces to the optic part of the lens. The optic part is free from any stress which contributes to high stability in the capsule bag.
A B
0°C-50°C-100°C 100°C50°C
Silicone Tg < -100°C PMMA Tg > 100°C11°C
RUMEX hydrophobic
acrylic IOL
HYDROPHOBIC IOLs
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
RUMEX IOL has a high , compared to some other competitors on the market (fig.2).
Higher Abbe number Lower Abbe number
Figure 2. Abbe number comparison of the IOLs manufactured by different companies on the market
0
10
20
30
40
50
60
55
AMOAcrylic
50
RUMEXAquaFree
47
Crystallinelens
42
HoyaAcrylic
42
AMOSilicone
37
AlconAcrylic
Abbe number
Low chromatic aberration
is the failure of a lens to focus all colors to the same point.
Chromatic aberration of IOL material is a significant parameter for image quality and contrast sensitivity.
The is an important parameter for the material quality. A high Abbe number is associated with less chromatic aberration (chromatic dispersion) and better optical performance.
HYDROPHOBIC IOLs
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
Cells Lens capsule
PCO
Best- orrected isual cuity (BCVA)
Eight studies were conducted to check the best-corrected visual acuity (fig.3) of the patients with the RUMEX AquaFree IOL implanted.
The data reported demonstrate that all the 344 patients had a BCVA of 20/40 or better, which is a better result compared to the historical control rate of 92.5%, as reported in ISO 11979-7.
Figure 3.
HYDROPHOBIC IOLs
Square edge of RUMEX IOL Square edge of a competitor’s IOL
prevent PCO caused by cellular migration.
Double square- dge
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
AQUAFREE YELLOW PRELOADED
Efficient minimal invasive surgery
• RUMEX Hydrophobic IOLs are suitable forincisions as small as 2.2 mm
• The preloaded system represents injection• Now the lens fits more accurately inside the lens box in the cartridge, and it's easier
for the surgeon • injector ensures forceless one-hand injection without capsule
stretching• The and integrated cartridge of the fully single-use system ensure
simple and predictable IOL
1. Add viscoelastic under the plate and into the biggest part of the tip
2. Close the flap and lock in position
3. Inject the lens with one continuous motion until the lens is out.
*RUMEX is an official distributor of Swiss company Medicel in all countries with the exception of theUnited Kingdom, Italy, Ireland and Brazil
HYDROPHOBIC IOLs
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
HYDROPHOBIC IOLs
AQUAFREE YELLOW / AQUAFREE YELLOW PRELOADED
Foldable aspheric monofocal one-piece IOLs
AquaFree Yellow Aspheric*
AquaFree Yellow Aspheric Preloaded*
Min. incision size 2.2 mm
Overall diameter 13.0 mm
Optic diameter 6.0 mm
Power rangeD to +9D (1D steps)
+10D to +30D (0.5D steps)
Self-unfolding Yes
Water content <0.5%
Angulation 0°
Material Natural Yellow Hydrophobic Acrylic
Optic design Biconvex, square edgeRefractive index 1.5
Abbe number 50
Nominal A-constant 118.7
Optimized optical constants
Haigis: a0=1.32, a1=0.40, a2=0.10
HofferQ: pACD=5.51
Holl.1: sf=1.75
SRK/T: 118.9
SRK II: 119.2
n: 190
Ref. : [304],[332]
Transition temp. of material 11°CFiltration UV and blue light (400-475 nm)AC-depth 5.51Shelf life 5 years
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
1
• Material (copolymer of hydrophilic and hydrophobic monomers) – high level ofbiocompatibility with a strong matrix, which exhibits excellent folding and unfoldingcharacteristics
• 5° angulation eliminates wrinkles and reduces PCO• Double square edge around entire optic periphery 360° barrier helps to prevent
PCO caused by cellular migration• Co- spheric optic design minimizes glare and unwanted images• IOL’s center thickness is 0.51 mm for 10.0 power
0.80 mm for 20.0 power1.10 mm for 30.0 power
The periphery thickness is 0.25 mm for all powers• Not tacky – a lens does not stick to itself or instruments• No vacuoles or glistening due to the fact that the lenses are lathe cut and not molded.
Molded lenses trap air which will produce vacuoles and glistenings• Finite Element Analysis (FEA) geometry designed to minimize capsular bag stretching• Method of Sterilization: Steam Sterilization at 121 °C
Co-aspheric optic design
Every human cornea has some level of asphericity, some positive and some negative. Some IOLs are intended to correct one or the other with either positive or negative asphericity on one side of the lens. However, this "one size fits all" approach in many cases leaves too little correction or even overcorrection which leaves the eye in a worse condition than before.
Standard non-aspheric IOLs introduce additional sphericalaberrations into the eye. Co-aspheric lenses like RUMEX have
. In this way, the eye is neither over - nor undercorrected but is left in the natural state without any additional aberrations introduced by the lens itself.
RUMEX Hydrophilic IOLs add no spherical aberration
Image with an aspheriс IOL implanted
Image with a non-aspheric IOL implanted
HYDROPHILIC IOLs
RUMEX HYDROPHILIC IOLS
Highly biocompatible hydrophilic material of RUMEX Hydrophilic IOLs with a exhibits . During the
manufacturing process, the lens material is tray-polymerized and then eliminating the occurrence of vacuoles or glistenings. The lathe cutting forms a genuine
a result not possible with injection molding. Bi convex aspheric optic design, extreme square-edge, and high-quality material are the features of the RUMEX Hydrophilic IOLs.
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
1
Best- orrected isual cuity
A study was conducted to check the best-corrected visual acuity (fig. ) of the patients with the RUMEX Hydrophilic IOL implanted.
The data reported for study demonstrate that almost 98% of the 266 patients had a BCVA of 20/40 or better, which is a better result compared to the historical control rate of 92.5%, as reported in ISO 11979-7.
Figure 4.
Better or = 20/40
Worse than 20/40
Totals
RUMEX Hydro-Sense
25997.37%
72.63%
266
Historical controls
389392.47%
3177.53%
4210
Totals 4152 324 4476
UV&blue light blocking
All RUMEX Hydrophilic IOLs contain a filter to block harmful ultra-violet (UV) light.
RUMEX Hydro-Sense Yellow also without blocking essential blue light , providing complete natural protection without losing contrast sensitivity or color perception. This helps to and prevent a common cause of visual loss among older people: age-related macular degeneration.
In charts below you can find the visible transmission spectrum of RUMEX Hydrophilic IOLs +20D.
HYDROPHILIC IOLs
SPECTRAL TRANSMITTANCE CURVE OF RUMEX HYDRO-SENSE IOL
The cutoff wavelength of 10% transmission for UV light is 380 nm.
SPECTRAL TRANSMITTANCE CURVE OF RUMEX HYDRO-SENSE YELLOW IOL
The cutoff wavelength of 10% transmission for UV light is 410 nm.
300 330 360 390 420 450 480 5100
20
40
60
80
100
TRA
NSM
ITTA
NC
E (%
)
WAVELENGTH (nm)300 330 360 390 420 450 480 5100
20
40
60
80
100
TRA
NSM
ITTA
NC
E (%
)
WAVELENGTH (nm)
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
1
C
M
Y
CM
MY
CY
CMY
K
C
M
Y
CM
MY
CY
CMY
K
1
HYDRO-4 ASPHERIC, HYDRO-SENSE ASPHERIC, HYDRO-SENSE ASPHERIC YELLOW
Foldable aspheric monofocal one-piece IOLs
Hydro-4 Aspheric*Hydro-Sense
Aspheric*Hydro-Sense
Aspheric Yellow*
Min. incision size 1.8 mm suitable for MICS
2.2 mm
Overall diameter 11 mm 12.5 mm
Optic diameter 6.0 mm
Power range-5D to +9D (1D steps)
+14D to +25D (0.5D steps)+25D to +38D (1D steps)
Self-unfolding Yes
Water content 23.5 – 27.5 %
Angulation 5°
Material Hydrophilic AcrylicNatural Yellow
Hydrophilic Acrylic
Optic design Biconvex, square edgeRefractive index 1.46
Abbe number 55
Nominal A-constant 118.0
Optimized Optical constants
HofferQ: pACD=5.08
Holl.1: sf=1.31
SRK/T: 118.2
SRK II: 118.5
n: 213
Ref. :[341]
Filtration UV UV and blue light