Hydrogel Self-Powered Pump for Preventing Blood Flowing Back
20091810 김영완
20091855 장욱일
20101899 장수영
20101885 이원진
![Page 2: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/2.jpg)
Patients on ringer drip usually experience blood flow backward along a tube.
It doesn’t dangerous, but, If this condition maintains more than a minute, The tube must be replaced because of coagulation( 응고 ) and contamination.
1.Problem
It causes to inject ringer, again
![Page 3: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/3.jpg)
Another inconvenience is patients must use long and heavy ringer stand. It is uncomfortable in toilet, and outside
1.Problem
![Page 4: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/4.jpg)
H = 50cm
Blood Pressure in vein: 7mmHg~14mmHg
H
1.Problem – Ringer injection mechanism
Hydrostatic Pressure
Blood Pressure in vein
Blood Flowing back conditions
1.H is shorter than 20cm2.Temporal blood pressure increase because of patients movements
![Page 5: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/5.jpg)
1. Make pressure Supporting device to prevent blood flow back
2. Objective
![Page 6: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/6.jpg)
1. Make pressure Supporting device to prevent blood flow back
2. Stick Ringer pack on a shoulder, without any stand, supply medicine using pump not gravity.
2. Objective
![Page 7: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/7.jpg)
3. Specific goals – hydrogel pump
1. Operate more than 3hours
2. Making pressure gradient more than 5Kpa
3. Self-Powered
![Page 8: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/8.jpg)
4. Design
펌프의 작동원리는 기본적으로 그림에서 보는 것과 같이 membrane 안에 hydrogel 이 있고 물을 떨어뜨렸을 때 hydrogel 이 팽창하여 채널 속 유체를 밀어내 압력을 가하는 방식이다 . 우리가 만들고자 하는 혈액 역류 방지 펌프에 적용하기 위한 설계는 조금 더 생각해볼 예정이다 .
“A water-activated pump for portable microfluidic applications”, Brian T. Good, 31 August 2006
Use hydrogel
The mechanism of the device is that hydrogel in closed cell push a membrane, when water added
The push makes pressure in a channel
![Page 9: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/9.jpg)
현재 논문으로 밝혀진 hydrogel 을 기반으로 한 microfluidic pump 의 압력범위는 약 1 kPa 에서 부터 10~15kPa 정도의 압력을 내는 것까지 다양하다 . 따라서 , 우리가 제작하려는 역류방지펌프의 압력을 충분히 낼 수 있을 거라고 판단하였다 .
“Micropumps operated by swelling and shrinking of temperature-sensitiveHydrogels” , Andreas Richter, 31st October 2008
According to a Paper below, micro fluidic pump based hydrogel make various levels of pressure .
Small : 1kpaLarge : 10~15kpa
4. Design
![Page 10: Hydrogel Self-Powered Pump for Preventing Blood Flowing Back 20091810 김영완 20091855 장욱일 20101899 장수영 20101885 이원진](https://reader036.vdocuments.mx/reader036/viewer/2022081506/5697c01b1a28abf838ccf8cd/html5/thumbnails/10.jpg)
Q&A