-1- HYDRO-TOWER 200 200 INSTALLATION INSTRUCTIONS IN-WALL TANK K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNE K-20008T-PNE/K-20008K-PNE/K-78073T-PNE/K-78073K-PNE K-78074T-PNE/K-78074K-PNE/K-78075T-PNE/K-78075K-PNE K-20341T-PNE ! ! ! ! ! Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid product damage and installation inconvenience caused by inappropriate operation. All data contained is based upon the last product information available at the time of publication. Kohler Company reserves the right to implement changes of product characteristics, packaging and availability at any time without further notice. Do not apply erosive cleanser and solvent in the tank, which will damage tank spares and result in leakage in the tank. Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used. Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares. Kohler will not be responsible for any damage related to installation with spares not provided by Kohler. This product complies with GB26730-2011. ! ! ! ! ! GB26730-2011 200 ,2.6/4L ......................................................................................................................K-20006T-PNE 200 ,2.6/4L ......................................................................................................................K-20006K-PNE 200 ,3/4.5L ......................................................................................................................K-20007T-PNE 200 ,3/4.5L ......................................................................................................................K-20007K-PNE 200 ,3/6L .........................................................................................................................K-20008T-PNE 200 ,3/6L .........................................................................................................................K-20008K-PNE 200 ,2.6/4L( ) ..............................................................................................K-78073T-PNE 200 ,2.6/4L( ) ..............................................................................................K-78073K-PNE 200 ,3/4.5L( ) ..............................................................................................K-78074T-PNE 200 ,3/4.5L( ) ..............................................................................................K-78074K-PNE 200 ,3/6L( )..................................................................................................K-78075T-PNE 200 ,3/6L( ) .................................................................................................K-78075K-PNE ( )( ) ........................................................................................................................K-20341T-PNE Ordering Information HYDRO-TOWER 200 PNE IWT 2.6/4L ....................................................................................................................K-20006T-PNE HYDRO-TOWER 200 PNE IWT 2.6/4L .....................................................................................................................K-20006K-PNE HYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007T-PNE HYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007K-PNE HYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008T-PNE HYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008K-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ..............................................................................................K-78073T-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ...............................................................................................K-78073K-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074T-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074K-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075T-PNE HYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075K-PNE PEBBLE Pneumatic In-Wall Tank Faceplate (For Separate Purchase) ...................................................................K-20341T-PNE BEFORE YOU BEGIN BEFORE YOU BEGIN KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD, JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436 ( ) 158 200436 © © Copyright Kohler China Investment Co., Ltd. 2016 2016 1288818-T01-A

Upload: vandung

Post on 11-Jan-2019

241 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-1-

HYDRO-TOWER 200200

INSTALLATION INSTRUCTIONS

IN-WALL TANK

K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNEK-20008T-PNE/K-20008K-PNE/K-78073T-PNE/K-78073K-PNEK-78074T-PNE/K-78074K-PNE/K-78075T-PNE/K-78075K-PNE

K-20341T-PNE

Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid

product damage and installation inconvenience caused by inappropriate operation.

All data contained is based upon the last product information available at the time of publication. Kohler Company reserves

the right to implement changes of product characteristics, packaging and availability at any time without further notice.

Do not apply erosive cleanser and solvent in the tank, which will damage tank spares and result in leakage in the tank.

Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used.

Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the

installation of Kohler spares. Kohler will not be responsible for any damage related to installation with spares not provided by

Kohler.

This product complies with GB26730-2011.

� GB26730-2011

200 ,2.6/4L ......................................................................................................................K-20006T-PNE200 ,2.6/4L ......................................................................................................................K-20006K-PNE200 ,3/4.5L ......................................................................................................................K-20007T-PNE200 ,3/4.5L ......................................................................................................................K-20007K-PNE200 ,3/6L .........................................................................................................................K-20008T-PNE200 ,3/6L .........................................................................................................................K-20008K-PNE200 ,2.6/4L( ) ..............................................................................................K-78073T-PNE200 ,2.6/4L( ) ..............................................................................................K-78073K-PNE200 ,3/4.5L( ) ..............................................................................................K-78074T-PNE200 ,3/4.5L( ) ..............................................................................................K-78074K-PNE200 ,3/6L( )..................................................................................................K-78075T-PNE200 ,3/6L( ) .................................................................................................K-78075K-PNE

( )( ) ........................................................................................................................K-20341T-PNE

Ordering Information

HYDRO-TOWER 200 PNE IWT 2.6/4L ....................................................................................................................K-20006T-PNEHYDRO-TOWER 200 PNE IWT 2.6/4L.....................................................................................................................K-20006K-PNEHYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007T-PNEHYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007K-PNEHYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008T-PNEHYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ..............................................................................................K-78073T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ...............................................................................................K-78073K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075K-PNEPEBBLE Pneumatic In-Wall Tank Faceplate (For Separate Purchase) ...................................................................K-20341T-PNE

BEFORE YOU BEGINBEFORE YOU BEGIN

KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436

( ) 158 200436

©

©

Copyright Kohler China Investment Co., Ltd. 2016

20161288818-T01-A

Page 2: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-2-

Advantages Of In-wall Tank

Made ofmacromolecular materials thatprevents corrison and leaking.

Will not affect the structure of the wall and provides excellent sound insulation.

Easy installation and time efficient.

.

.

Clean, garbage free, and space .

Advanced water tank fitting, which makes possible the adjustment of the water discharge and double flush.

Do notneed toprepare any other spare parts

Easymaintenance and servicing

saving

Design And Installation Concept Of In-wall Tank

Installation of in-wall tank is much easier and nice-looking comparative to that of traditional tank. Meanwhile, the space

layout will be more reasonable due to the application of in-wall tank pipes and connectors.

The most remarkable advantage of in-wall tank is that the installation will never be limited to certain area, and can be

installed wherever as you wish, which will make the bathroom layout more reasonable and nice-looking, and make good use

of every inch of the bathroom space.

Function Explanation

Anti flow-backwardsAdjustment of inlet water levelAdjustment of flushing volumeSingle/double gearAssemble, disassemble andmaintenance can be done withouttools.

flushing

1288818-T01-A

Page 3: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

SPECIFICATIONS

RECOMMENDES TOOLS AND MATERIALSRECOMMENDES TOOLS AND MATERIALS

Liter per flushing

Temperature

Environmental temperature: 1 ~55Water temperature: 1 ~45

°C °C,

°C °C

°C °C

°C °C

1 ~551 ~45

Full flushing volume:Half flushing volume:

6L3L

6L3L

K-20007T-PNEK-20007K-PNEK-78074T-PNEK-78074K-PNE

K-20008T-PNEK-20008K-PNEK-78075T-PNEK-78075K-PNE

Full flushing volume: 4.5LHalf flushing volume: 3L

4.5L3L

K-20006T-PNEK-20006K-PNEK-78073T-PNEK-78073K-PNE

Full flushing volume: 4LHalf flushing volume: 2.6L

4L2.6L

Open end/adjustable wrenchesAllen wrenchKnifeFileHacksawMasonryLevelScrew driverInsulation tapeTape measureSeal tapeBushingLubricant

/

-3-1288818-T01-A

Page 4: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

ROUGHING-IN

UNIT: mmReference Value

-4-

K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNE/K-20008T-PNE/K-20008K-PNE

Method four:Press from front

Method four:Press from front

K-78073T-PNE/K-78073K-PNE/K-78074T-PNE/K-78074K-PNE/K-75075T-PNE/K-78075K-PNE

478 3

35

2

100 2

180 3

230 3

90 0.5

438 3150~185

Air hose

Finishedfloor

Air hose Air hose

Pinchplate

Suggested faceplateinstallation area

R1000mm

Suggested faceplateinstallation area

R1000mm

Installed withK-20341T-PNE

K-20341T-PNE

Method one:Press from top

Method two:Remote plate installation

Method three:Remote installation

of mask

Heig

htS

uggeste

d/

800

710

490~

190

205

85~93

477 3

152 3

134 2

461

3322

397

2

440 3

Installed with K-20341T-PNEK-20341T-PNE

Method one:Press from top

Method two:Remote plate installation

Method three:Remote installation

of mask

Air hose

Air hose

Air hose

Air hose

Air hose

Pinchplate

Pinch plate

Pinch plate

Suggested faceplateinstallation area

R1000mm

Suggested faceplateinstallation area

R1000mm

60

1

Finished wall

Finished wall

23~

72

23~

72

At least80mm gapreserved

80mm

At least80mm gapreserved

80mm

Finished Floor

Height to floor is decided by bowl.

1288818-T01-A

Page 5: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

Kohler reserves the right to change marked dimensions without prior notice.

-5-

Floor Discharge Installation Method

There are three methods (A, B and C) for drainage pipe

installation. Loosen the knob open on the fixing frame, put

the drainage pipe into the fixing frame, then adjust and

tighten the knob lock . Fill the bottom of the drainage pipe in

the drainage hole .

" "

" "

A B C

open

lock

B

C

A

DischargeElbow

DischargeElbow

DischargeElbow

Water TankBracket

Water TankBracket

Water TankBracket

Drain outlet 90mm, welding90mm

Drain outlet 110mm110mm

Drain outlet 110mm, welding110mm

Drainage Pipe

Tank Bracket

Bottom of the Drainage Pipe

Drainage Hole

Fixing Frame

Knob

1288818-T01-A

Page 6: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

Screw Base

NutFrame Screw

Screw Cap

Tank Frame

-6-

INSTALLATION

Way of Installation

There are two ways to install this product: in-wall tank withframe & in-wall tank without frame

( )

( )

In-wall Tank Without Frame( )

In-wall Tank With Frame( )

Installation For In-wall Tank With Frame

A. Installation of In-wall Tank

( )

A.

1. Remove in-wall tank from packing box. Remove front coverboard or top cover board inside water tank first as shown.Then remove support block and plug above bracketassembly.

1.

2. Insert the frame screw and screw cap in the holes of fixingframe, lock the frame screw with nut, then tighten theframe screws on the fixing frame with medium Allen key asshown in illustration A.Tighten the bolts with medium Allen key as shown inillustration B, and adjust the height of the adjustablebracket according to customer's requirements.

2. A

B

A

B

Plug Cover,Top

Cover,Front

Supporting Board

Nut

Medium Allen Key

Adjustable Bracket

Cover,Top Cover,Front

1288818-T01-A

Page 7: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-7-

Connect with overflow pipe on the side when installing

K-20006K-PNE/K-20008K-PNE.

K-20006K-PNE/K-20008K-PNE

A

B

Overflow Pipe

3. Drill four holes with diameter of 10mm and depth of 80mm

with churn drilling as shown, and fill in the holes with bulge

screw and tighten the screw.

3. 10mm 80mm

Bulge Screw

Gasket

Bulge Screw Cap/Bolt/

4. Tighten the hexagonal long screw with medium Allen keyas shown in illustration A.Tighten the screw of adjustable brackets with mediumAllen key as shown in illustration B, and tighten the longscrew with spanner.

NOTE: Ensure the tank to remain level.

4. A

B

Hexagonal Screw

LoosenTightenLevel

Medinm Allen Key

Adjustable BracketSpanner

Screw

1288818-T01-A

Page 8: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-8-

2. Tighten the long screw into the holes of the tank bracket

and cover the drainage hole with the big cap, cover the

inlet hole with the small cap.

2.

Inlet Hole

Drainage Hole

Big Cap

Tank Bracket

Small Cap

Long Screw

3. Connect tap water braided tube on the top of water tank forwater supply as shown.

Note: 1. Ensure water tank internal valve is OFF.2. Suggestion: connect a temporary rubber or plastic

hose on valve, flush water supply pipeline. Ensurewater is clean, no residual sand stone or foulinginside pipeline.

3.

1.

2.

B. Floor Discharge Installation Method

B.

1. There are three methods (A, B and C) for drainage pipeinstallation. Loosen the knob open on the fixing frame,put the drainage pipe into the fixing frame, then adjust andtighten the knob lock . Fill the bottom of the drainage pipein the drainage hole .

" "

" "

1. A B C

open

lock

B

C

A

DischargeElbow

DischargeElbow

DischargeElbow

Water TankBracket

Water TankBracket

Water TankBracket

Drain outlet 90mm, welding90mm

Drain outlet 110mm110mm

Drain outlet 110mm, welding110mm

Drainage Pipe

Tank Bracket

Bottom of the Drainage Pipe

Drainage Hole

Fixing Frame

Knob

Water Pipe

Connecting Pipe

1288818-T01-A

Page 9: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-9-

4. Access Panel Installation Methods:

There are four ways to install access panel:

Method one: Press from top

Method two: Remote plate installation: fix four plates with

screws

Method three: Remote installation of mask

Method four: Press from front: fix four plates with screws

4.

:

2) Cut apart the cable of the air hose and pull it out from

the mask.

2)

5. Method one: Install mask when pressing from top

1) Remove top plate, then install the rectangular shield on

the top of the tank, and tighten the screw to fix the mask

to the tank.

5.

1)

Air hose

Suggested faceplateinstallation area

R1000mm

Method three:Remote installation

of maskMethod four:

Press from front

Air hose

Pinch plate

Finishedwall

Air hose

Pinchplate

Suggested faceplateinstallation area

R1000mm

Method one:Press from top

Method two:Remote plate installation

23~

72

Cover,Top

Screw

Mask

Cable

At least80mm gapreserved

80mm

1288818-T01-A

Page 10: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

6. Methods two and three: During remote installation, fix the

cover onto the tank and pull the air hose to the panel.

Reserve access panel at front or top to ensure removal

and installation of cover.

Method two: During remote plate installation, 7~20mmthickness is recommended for the wall of the pinch plateand at least 80mm gap is reserved.Method three: During remote installation of mask, 4 holeswith diameter of 10mm and depth of 16mm are needed tobe reserved at the locating hose. Drill 10mm holes throughair hose on the side of mask.

6.

7~20mm 80mm

4

10mm 16mm 10mm

7. Method four: Cut apart the cable of the air hose. Pull it outfrom the front of the tank and meanwhile reserve theaccess panel. Fix the four plates with screws and then fixthe support board.

No direct contact between the faceplate and the tank.7~20mm thickness recommended for the wall of thepinch plate.

Note:

7.

7~20mm

Cover,Top

Cover,Front

At least 80mm gap reserved80mm

At least 80mm gap reserved80mm

At least 80mm gap reserved80mm

Pinch plate installation

Screw

Air hose

Air hose

Air hose

Pinch plate

Pinch plate

Pinch plate

Pinch plate

Finished wall

Finished wall

Finished wall

Faceplate

Supporting Board

SupportingBoard

SupportingBoard

-10-

Method four:Press from front

Air hose

Finishedwall

Fix Mask Onto Wall

72

7~20mm recommended7~20mm

7~20mm recommended7~20mm

10 Hole through hose

10

10 Depth 16,Space reserved10 16

1288818-T01-A

Page 11: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-11-

2. Tighten the long screw into the holes of the tank bracketand cover the drainage hole with the big cap, cover theinlet hole with the small cap.

2. Long Screw

Water Inlet

Drainage Hole

Big Cap

Water Tank Bracket

Small Cap

3.

3. When finishing the brickwork of the wall, take out the big

and small caps, and eliminate unwanted mask with a sharp

knife, if there is mask.

Reserve access panel at front or top of the tank.Note:

D. Installation of Toilet

D.

1. Install the inlet pipe to the lavatory as shown, and mark onthe pipes at the back side of the tank with a ruler and apencil, and reserve appropriate space according to thedistance from the back of the tank to the inlet hole on thewall.

1.

Inlet Pipe

Drainage Pipe

C. Installation of P-trap

C.

1. Insert drainage pipe with inner diameter 110mm intodrain elbow and weld.

1. 110mm

Water Tank Bracket

Drainage Pipe

Mask

Big Cap

Small Cap

Access Panel

Access Panel

1288818-T01-A

Page 12: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-12-

3. Install the big and small leak-proof gaskets on inlet pipeand outlet pipe ,then install it to corresponding pipes on thetoilet tank.

3.

4. 48mm-58mm of the long screw shall be reserved outsidethe wall as shown in the illustration. if the long screwoutside the wall is not long enough or much longer thanthat needed, it should be adjusted with screwdriver or byhand. Then apply lubricant to drainage pipe and limberpipe to ensure a smooth installation.

4. 48mm-58mm 48mm-58mm

Long Screw

Lubricant

Small Leak-proof Gasket

Inlet Pipe

Drainage Pipe

Big Leak-proof Gasket

5. Install the toilet as shown in the illustration, and use a spirit

level to ensure the lavatory to remain level.

5.

Spirit Level

2.

Inlet Pipe

Reserved Space

Drainage Pipe

2. Eliminate unwanted part of the inlet pipe according to themarks of reserved space ,and rasp a smooth surface withfiles.

1288818-T01-A

Page 13: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-13-

E. Faceplate Installation

E.

1.

1. OPEN

When tighten four locknuts on supporting board, adjust to

"OPEN" mark as shown.

Supporting Board

Locknut

2. Tighten four screws to "LOCK" mark after installing

supporting board as shown.

2. LOCK

Gasket

Long Screw

Reversed Lock

Hexagonal Nut

Decoration Cap

6. Install the reserved lock, gasket, hexagonal nut anddecoration cap onto long screw according to the ordershown in the illustration.

Please refer to the installation instructions of toilet.Note:

6.

3. Install the big flush air hose and small flush air hose to thecover.

Cut the excessive parts of the air hose if necessary andfix it onto the tank fastener.

Put the lock on the cover directly on the reversedlock on supporting board, then push the cover and lock it.The installation shall begin from bottom to top.

Note:

3.

Faceplate

Lock

Faceplate

SupportingBoard

Connect to air hoseFastener

1288818-T01-A

Page 14: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-14-

2. Make sure of h according to dimensions of bowl and then

locate the installation hole of fixing bracket. Mark on the

wall for appropriate position for fixing bracket, and drill four

holes with diameter of 10mm and depth of 80mm with

churn drilling as shown in illustration, and fill in the holes

with bulge screw and tighten the screw to set the fixing

bracket.

Note: Ensure the fixing bracket to remain level.

2. h

10mm 80mmO

Fixing Bracket

Bulge Screw

Gasket

Spring

Nut

Installation For In-wall Tank Without Frame

A. Installation of In-wall TankA.

4. It is ready to use when connected to water supply afterinstallation.

Reserve access panel at front or top of the tank inremote installation.Note:

4.

Half Flush Button

Full FlushButton

h

1. Remove in-wall tank from packing box. Remove front coverboard or top cover board inside water tank first as shown.Then remove support block and plug above bracketassembly.

1.

Cover,Top

Cover,Front

Plug Cover,Top

Cover,Front

Supporting Board

1288818-T01-A

Page 15: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-15-

3. Put the tank onto the fixing bracket as shown in the right

figure and adjust the tank to level . Then tighten screws

with hex-head key.

it is a must to keep the tank level.Note:

3.

Screw

Level

Tank

TightenLoosen

MediumAllen Key

4. Connect with overflow pipe on the side when installing

K-78073K-PNE/K-78075K-PNE.

4. K-78073K-PNE/K-78075K-PNE

Overflow Pipe

5. Connect tap water braided tube on the top of water tank forwater supply as shown.

Note: 1. Ensure water tank internal valve is OFF.2. Suggestion: connect a temporary rubber or plastic

hose on valve, flush water supply pipeline. Ensurewater is clean, no residual sand stone or foulinginside pipeline.

5.

1.

2.

Water Pipe

Connecting Pipe

6. Access Panel Installation Methods:

There are four ways to install access panel:

Method one: Press from top

Method two: Remote plate installation: fix four plates with

screws

Method three: Remote installation of mask

Method four: Press from front: fix four plates with screws

6.

:

Method one:Press from top

Method four:Press from front

Method two:Remote plate installation

Method three:Remote installation

of mask

Air hose

Air hose

Air hose

Pinchplate

Pinch plate

Suggested faceplateinstallation area

R1000mm

Suggested faceplateinstallation area

R1000mm

Finished wall

23~

72

At least80mm gapreserved

80mm

1288818-T01-A

Page 16: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-16-

2) Cut apart the cable of the air hose and pull it out from

the rectangle cover.

2)

7. Method one: Install mask when pressing from top

1) Remove top plate, then install the mask on the top of the

tank, and tighten the screw to fix the mask to the tank.

7.

1)

Cover,Top

Screw

Mask

Cable

Cover,Top

Cover,Front

8. Methods two and three: During remote installation, fix the

cover onto the tank and pull the air hose to the panel.

Reserve access panel at front or top to ensure removal

and installation of cover.

Method two: During remote plate installation, 7~20mmthickness is recommended for the wall of the pinch plateand at least 80mm gap is reserved.Method three: During remote installation of mask, 4 holeswith diameter of 10mm and depth of 16mm are needed tobe reserved at the locating hose. Drill 10mm holes throughair hose on the side of the mask.

8.

7~20mm 80mm

4

10mm 16mm 10mm

At least 80mm gap reserved80mm

Air hose

Pinch plate

Finished wall

SupportingBoard

Air hose

Finishedwall

72

7~20mm recommended7~20mm

10 Hole through hose

10

10 Depth 16,Space reserved10 16

1288818-T01-A

Page 17: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

10. Insert the inlet pipe and drainage pipe into the bowl, andthen adjust the syphon and drainage pipe to a properposition to be fixed into the bowl. Make sure of thepositions of syphon and discharge elbow and thenremove the bowl.

10.

Inlet Pipe

Syphon

Discharge Elbow Drainage Pipe

-17-

Pinch plate installation

Screw

Air hose

Pinch platePinch plate

Finished wall

Faceplate

Supporting Board

9. Method four: Cut apart the cable of the air hose. Pull it outfrom the front of the tank and meanwhile reserve theaccess panel. Fix the four plates with screws and then fixthe support board.

No direct contact between the faceplate and the tank.7~20mm thickness recommended for the wall of thepinch plate.

Note:

9.

7~20mm

Method four:Press from front

Air hose

Pinch plate

Finished wall

7~20mm recommended7~20mm

At least 80mm gap reserved80mm

At least80mm gapreserved

80mm

1288818-T01-A

Page 18: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-18-

12. Fix faceplate according to step E and then it is ready for

use.

Reserve access panel at front or top of the tank in

remote installation.

Note:

12. E

Half Flush Button

FullFlush Button

Finished Installation Illustration

11. When finishing the brickwork, eliminate unwanted part ofthe mask, the drainage pipe and the inlet pipe, if there ismask.

11. Inlet Pipe

Drainage Pipe

1.

1. Remove the air hoses of the big flush and small flush.

Then remove the faceplate.

REMOVE AND MAINTENANCE OF THE OUTLET VALVEREMOVE AND MAINTENANCE OF THE OUTLET VALVE

Faceplate

Faceplate

Connect to air hose

Mask

1288818-T01-A

Page 19: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-19-

3. Dismantle supporting board as shown.

3.

2. Pay special attention when dismantle supporting board 4lock nuts, all bolts shall align with "OPEN" mark.

2. OPEN

5. Unscrew the nut of the metal weaved hose and push theconnector of the inlet valve as shown to remove the inletvalve.

5.

4. Open/close water supply

Rotate valve switch to open/close water supply as shown.

4.

Valve

Close

Open

Conntector,Quick release

Metal weaved hose nut

Supporting Board

Locknut

1288818-T01-A

Page 20: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-20-

Fastener

Fastener

8. Hold fastener by hand as shown, pull the top of fastener

along the direction of arrow. Then remove fastener.

8.

6. Push aside the snap of the toilet detergent box to take thebox out.

6.Snap

7. Push aside the pivot snaps of the big flush and small flushtowards upper right to make the lever and pivot apart. Holdbracket top by hand and then lift up to unlock the bracket.

Push aside the pivot snaps of the big flush and smallflush towards lower left to fix back the bracket. Lock the snap.Note:

7.

Lever Snap

Snap (Locked)( )

9. Pull discharge valve along the arrow direction as shown toremove discharge valve.

9.

Outlet Valve

1288818-T01-A

Page 21: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-21-

10. Remove discharge valve as shown and then take valveout for cleaning or adjusting.

10.

Outlet Valve

Outlet Valve

B.

(1)(2)

Floating Box

Drainage valveAdjustment Switch

B. Adjust Drainage Valve

Drainage volume and overflow level of the tank can beadjusted by drainage valve:1) heavy drainage adjustment:open adjustment switch to open the small hole. 2) slightdrainage adjustment: adjust the height of floating box andthe water level of slight drainage will be at the bottom ofthe floating box.

A Wash Filtration Net

Close corner valve first, then loosen and take out the tightennut, and wash the waste on filtration net with clean water.Then reset the tighten nut to the original position.

.

A.

Tighten

Close

Open

Corner

Open

A

Tighten

Close

C

Filtration Net

B

Press for Top

1288818-T01-A

Page 22: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

-22-

TROUBLE SHOOTING PROCEDURESTROUBLE SHOOTING PROCEDURES

No water fills in via inletvalve

The inlet valve is closed. Open inlet valve.

Floating box of inlet valve is blocked by other parts.

Floating box of inlet valve is block by waste. Wash the floating box with clean water.

The air hose and faceplate are wrongly installed. Reinstall the air hose.No drainage whenpressing the heavy andslight drainage button

Too high or too low waterlevel

Leak of the toilet andsquat

Toilet does not flush

Toilet does not flushcompletely

Symptoms Probable Causes Recommended Action

The pole and the reversed lock are not connected. Reinstall the reversed lock onto the pole ofthe outlet valve.

The floating box of the inlet valve is not properlyadjusted.

Readjust the water level.

The floating box of the inlet valve is blocked bywastes, so the water is leaked from the overflowpipe.

A. No water supply.B. The water supply stop is closed.

Readjust the position of other parts to avoidcontacting the floating box when it isfunctioning.

A. Wait for restoration of water supply.B. Open the water supply stop.

Readjust the position of other parts to avoidcontacting the floating box when it isfunctioning.

The rubber gasket is blocked by wastes.

Filter screen is clogged.

Take out the outlet valve and clean thewastes.

Refer to wash filtration net.

C.

Control Pole

Inlet Valve

Floating Box

C. Adjust Inlet Valve

Hoist and reduce the water level in the tank by adjusting

the control pole. Turn the control pole counterclockwise to

lower down the floating box and reduce the water level of

the tank .turn the control pole clockwise to hoist the

floating box and increase the water level in the tank.

1288818-T01-A

Page 23: HYDRO-TOWER 200 200 - resources.kohler.comresources.kohler.com/plumbing/kohlerapac/pdf/K-20006,K-20007,K... · K-20007T-PNE K-20007K-PNE K-78074T-PNE K-78074K-PNE K-20008T-PNE K-20008K-PNE

A.B.

A.B.

-23-1288818-T01-A