hydro-tower 200 200 -...
TRANSCRIPT
-1-
HYDRO-TOWER 200200
INSTALLATION INSTRUCTIONS
IN-WALL TANK
K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNEK-20008T-PNE/K-20008K-PNE/K-78073T-PNE/K-78073K-PNEK-78074T-PNE/K-78074K-PNE/K-78075T-PNE/K-78075K-PNE
K-20341T-PNE
�
�
�
�
�
Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
product damage and installation inconvenience caused by inappropriate operation.
All data contained is based upon the last product information available at the time of publication. Kohler Company reserves
the right to implement changes of product characteristics, packaging and availability at any time without further notice.
Do not apply erosive cleanser and solvent in the tank, which will damage tank spares and result in leakage in the tank.
Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used.
Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the
installation of Kohler spares. Kohler will not be responsible for any damage related to installation with spares not provided by
Kohler.
This product complies with GB26730-2011.
�
�
�
�
� GB26730-2011
200 ,2.6/4L ......................................................................................................................K-20006T-PNE200 ,2.6/4L ......................................................................................................................K-20006K-PNE200 ,3/4.5L ......................................................................................................................K-20007T-PNE200 ,3/4.5L ......................................................................................................................K-20007K-PNE200 ,3/6L .........................................................................................................................K-20008T-PNE200 ,3/6L .........................................................................................................................K-20008K-PNE200 ,2.6/4L( ) ..............................................................................................K-78073T-PNE200 ,2.6/4L( ) ..............................................................................................K-78073K-PNE200 ,3/4.5L( ) ..............................................................................................K-78074T-PNE200 ,3/4.5L( ) ..............................................................................................K-78074K-PNE200 ,3/6L( )..................................................................................................K-78075T-PNE200 ,3/6L( ) .................................................................................................K-78075K-PNE
( )( ) ........................................................................................................................K-20341T-PNE
Ordering Information
HYDRO-TOWER 200 PNE IWT 2.6/4L ....................................................................................................................K-20006T-PNEHYDRO-TOWER 200 PNE IWT 2.6/4L.....................................................................................................................K-20006K-PNEHYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007T-PNEHYDRO-TOWER 200 PNE IWT 3/4.5L ....................................................................................................................K-20007K-PNEHYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008T-PNEHYDRO-TOWER 200 PNE IWT 3/6L .......................................................................................................................K-20008K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ..............................................................................................K-78073T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 2.6/4L ...............................................................................................K-78073K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/4.5L ..............................................................................................K-78074K-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075T-PNEHYDRO-TOWER 200 PNE IWT W/O FRAME 3/6L .................................................................................................K-78075K-PNEPEBBLE Pneumatic In-Wall Tank Faceplate (For Separate Purchase) ...................................................................K-20341T-PNE
BEFORE YOU BEGINBEFORE YOU BEGIN
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
( ) 158 200436
©
©
Copyright Kohler China Investment Co., Ltd. 2016
20161288818-T01-A
-2-
�
�
�
�
�
�
�
Advantages Of In-wall Tank
�
�
�
�
�
�
�
Made ofmacromolecular materials thatprevents corrison and leaking.
Will not affect the structure of the wall and provides excellent sound insulation.
Easy installation and time efficient.
.
.
Clean, garbage free, and space .
Advanced water tank fitting, which makes possible the adjustment of the water discharge and double flush.
Do notneed toprepare any other spare parts
Easymaintenance and servicing
saving
�
�
Design And Installation Concept Of In-wall Tank
�
�
Installation of in-wall tank is much easier and nice-looking comparative to that of traditional tank. Meanwhile, the space
layout will be more reasonable due to the application of in-wall tank pipes and connectors.
The most remarkable advantage of in-wall tank is that the installation will never be limited to certain area, and can be
installed wherever as you wish, which will make the bathroom layout more reasonable and nice-looking, and make good use
of every inch of the bathroom space.
�
�
�
�
�
Function Explanation
�
�
�
�
�
Anti flow-backwardsAdjustment of inlet water levelAdjustment of flushing volumeSingle/double gearAssemble, disassemble andmaintenance can be done withouttools.
flushing
1288818-T01-A
SPECIFICATIONS
RECOMMENDES TOOLS AND MATERIALSRECOMMENDES TOOLS AND MATERIALS
Liter per flushing
Temperature
Environmental temperature: 1 ~55Water temperature: 1 ~45
°C °C,
°C °C
°C °C
°C °C
1 ~551 ~45
Full flushing volume:Half flushing volume:
6L3L
6L3L
K-20007T-PNEK-20007K-PNEK-78074T-PNEK-78074K-PNE
K-20008T-PNEK-20008K-PNEK-78075T-PNEK-78075K-PNE
Full flushing volume: 4.5LHalf flushing volume: 3L
4.5L3L
K-20006T-PNEK-20006K-PNEK-78073T-PNEK-78073K-PNE
Full flushing volume: 4LHalf flushing volume: 2.6L
4L2.6L
�
�
�
�
�
�
�
�
�
�
�
�
�
Open end/adjustable wrenchesAllen wrenchKnifeFileHacksawMasonryLevelScrew driverInsulation tapeTape measureSeal tapeBushingLubricant
�
�
�
�
�
�
�
�
�
�
�
�
�
/
-3-1288818-T01-A
ROUGHING-IN
UNIT: mmReference Value
-4-
K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007K-PNE/K-20008T-PNE/K-20008K-PNE
Method four:Press from front
Method four:Press from front
K-78073T-PNE/K-78073K-PNE/K-78074T-PNE/K-78074K-PNE/K-75075T-PNE/K-78075K-PNE
478 3
35
2
100 2
180 3
230 3
90 0.5
438 3150~185
Air hose
Finishedfloor
Air hose Air hose
Pinchplate
Suggested faceplateinstallation area
R1000mm
Suggested faceplateinstallation area
R1000mm
Installed withK-20341T-PNE
K-20341T-PNE
Method one:Press from top
Method two:Remote plate installation
Method three:Remote installation
of mask
Heig
htS
uggeste
d/
800
710
490~
190
205
85~93
477 3
152 3
134 2
461
3322
397
2
440 3
Installed with K-20341T-PNEK-20341T-PNE
Method one:Press from top
Method two:Remote plate installation
Method three:Remote installation
of mask
Air hose
Air hose
Air hose
Air hose
Air hose
Pinchplate
Pinch plate
Pinch plate
Suggested faceplateinstallation area
R1000mm
Suggested faceplateinstallation area
R1000mm
60
1
Finished wall
Finished wall
23~
72
23~
72
At least80mm gapreserved
80mm
At least80mm gapreserved
80mm
Finished Floor
Height to floor is decided by bowl.
1288818-T01-A
Kohler reserves the right to change marked dimensions without prior notice.
-5-
Floor Discharge Installation Method
There are three methods (A, B and C) for drainage pipe
installation. Loosen the knob open on the fixing frame, put
the drainage pipe into the fixing frame, then adjust and
tighten the knob lock . Fill the bottom of the drainage pipe in
the drainage hole .
" "
" "
A B C
open
lock
B
C
A
DischargeElbow
DischargeElbow
DischargeElbow
Water TankBracket
Water TankBracket
Water TankBracket
Drain outlet 90mm, welding90mm
Drain outlet 110mm110mm
Drain outlet 110mm, welding110mm
Drainage Pipe
Tank Bracket
Bottom of the Drainage Pipe
Drainage Hole
Fixing Frame
Knob
1288818-T01-A
Screw Base
NutFrame Screw
Screw Cap
Tank Frame
-6-
INSTALLATION
Way of Installation
There are two ways to install this product: in-wall tank withframe & in-wall tank without frame
( )
( )
In-wall Tank Without Frame( )
In-wall Tank With Frame( )
Installation For In-wall Tank With Frame
A. Installation of In-wall Tank
( )
A.
1. Remove in-wall tank from packing box. Remove front coverboard or top cover board inside water tank first as shown.Then remove support block and plug above bracketassembly.
1.
2. Insert the frame screw and screw cap in the holes of fixingframe, lock the frame screw with nut, then tighten theframe screws on the fixing frame with medium Allen key asshown in illustration A.Tighten the bolts with medium Allen key as shown inillustration B, and adjust the height of the adjustablebracket according to customer's requirements.
2. A
B
A
B
Plug Cover,Top
Cover,Front
Supporting Board
Nut
Medium Allen Key
Adjustable Bracket
Cover,Top Cover,Front
1288818-T01-A
-7-
Connect with overflow pipe on the side when installing
K-20006K-PNE/K-20008K-PNE.
K-20006K-PNE/K-20008K-PNE
A
B
Overflow Pipe
3. Drill four holes with diameter of 10mm and depth of 80mm
with churn drilling as shown, and fill in the holes with bulge
screw and tighten the screw.
3. 10mm 80mm
Bulge Screw
Gasket
Bulge Screw Cap/Bolt/
4. Tighten the hexagonal long screw with medium Allen keyas shown in illustration A.Tighten the screw of adjustable brackets with mediumAllen key as shown in illustration B, and tighten the longscrew with spanner.
NOTE: Ensure the tank to remain level.
4. A
B
Hexagonal Screw
LoosenTightenLevel
Medinm Allen Key
Adjustable BracketSpanner
Screw
1288818-T01-A
-8-
2. Tighten the long screw into the holes of the tank bracket
and cover the drainage hole with the big cap, cover the
inlet hole with the small cap.
2.
Inlet Hole
Drainage Hole
Big Cap
Tank Bracket
Small Cap
Long Screw
3. Connect tap water braided tube on the top of water tank forwater supply as shown.
Note: 1. Ensure water tank internal valve is OFF.2. Suggestion: connect a temporary rubber or plastic
hose on valve, flush water supply pipeline. Ensurewater is clean, no residual sand stone or foulinginside pipeline.
3.
1.
2.
B. Floor Discharge Installation Method
B.
1. There are three methods (A, B and C) for drainage pipeinstallation. Loosen the knob open on the fixing frame,put the drainage pipe into the fixing frame, then adjust andtighten the knob lock . Fill the bottom of the drainage pipein the drainage hole .
" "
" "
1. A B C
open
lock
B
C
A
DischargeElbow
DischargeElbow
DischargeElbow
Water TankBracket
Water TankBracket
Water TankBracket
Drain outlet 90mm, welding90mm
Drain outlet 110mm110mm
Drain outlet 110mm, welding110mm
Drainage Pipe
Tank Bracket
Bottom of the Drainage Pipe
Drainage Hole
Fixing Frame
Knob
Water Pipe
Connecting Pipe
1288818-T01-A
-9-
4. Access Panel Installation Methods:
There are four ways to install access panel:
Method one: Press from top
Method two: Remote plate installation: fix four plates with
screws
Method three: Remote installation of mask
Method four: Press from front: fix four plates with screws
4.
:
2) Cut apart the cable of the air hose and pull it out from
the mask.
2)
5. Method one: Install mask when pressing from top
1) Remove top plate, then install the rectangular shield on
the top of the tank, and tighten the screw to fix the mask
to the tank.
5.
1)
Air hose
Suggested faceplateinstallation area
R1000mm
Method three:Remote installation
of maskMethod four:
Press from front
Air hose
Pinch plate
Finishedwall
Air hose
Pinchplate
Suggested faceplateinstallation area
R1000mm
Method one:Press from top
Method two:Remote plate installation
23~
72
Cover,Top
Screw
Mask
Cable
At least80mm gapreserved
80mm
1288818-T01-A
6. Methods two and three: During remote installation, fix the
cover onto the tank and pull the air hose to the panel.
Reserve access panel at front or top to ensure removal
and installation of cover.
Method two: During remote plate installation, 7~20mmthickness is recommended for the wall of the pinch plateand at least 80mm gap is reserved.Method three: During remote installation of mask, 4 holeswith diameter of 10mm and depth of 16mm are needed tobe reserved at the locating hose. Drill 10mm holes throughair hose on the side of mask.
6.
7~20mm 80mm
4
10mm 16mm 10mm
7. Method four: Cut apart the cable of the air hose. Pull it outfrom the front of the tank and meanwhile reserve theaccess panel. Fix the four plates with screws and then fixthe support board.
No direct contact between the faceplate and the tank.7~20mm thickness recommended for the wall of thepinch plate.
Note:
7.
7~20mm
Cover,Top
Cover,Front
At least 80mm gap reserved80mm
At least 80mm gap reserved80mm
At least 80mm gap reserved80mm
Pinch plate installation
Screw
Air hose
Air hose
Air hose
Pinch plate
Pinch plate
Pinch plate
Pinch plate
Finished wall
Finished wall
Finished wall
Faceplate
Supporting Board
SupportingBoard
SupportingBoard
-10-
Method four:Press from front
Air hose
Finishedwall
Fix Mask Onto Wall
72
7~20mm recommended7~20mm
7~20mm recommended7~20mm
10 Hole through hose
10
10 Depth 16,Space reserved10 16
1288818-T01-A
-11-
2. Tighten the long screw into the holes of the tank bracketand cover the drainage hole with the big cap, cover theinlet hole with the small cap.
2. Long Screw
Water Inlet
Drainage Hole
Big Cap
Water Tank Bracket
Small Cap
3.
3. When finishing the brickwork of the wall, take out the big
and small caps, and eliminate unwanted mask with a sharp
knife, if there is mask.
Reserve access panel at front or top of the tank.Note:
D. Installation of Toilet
D.
1. Install the inlet pipe to the lavatory as shown, and mark onthe pipes at the back side of the tank with a ruler and apencil, and reserve appropriate space according to thedistance from the back of the tank to the inlet hole on thewall.
1.
Inlet Pipe
Drainage Pipe
C. Installation of P-trap
C.
1. Insert drainage pipe with inner diameter 110mm intodrain elbow and weld.
1. 110mm
Water Tank Bracket
Drainage Pipe
Mask
Big Cap
Small Cap
Access Panel
Access Panel
1288818-T01-A
-12-
3. Install the big and small leak-proof gaskets on inlet pipeand outlet pipe ,then install it to corresponding pipes on thetoilet tank.
3.
4. 48mm-58mm of the long screw shall be reserved outsidethe wall as shown in the illustration. if the long screwoutside the wall is not long enough or much longer thanthat needed, it should be adjusted with screwdriver or byhand. Then apply lubricant to drainage pipe and limberpipe to ensure a smooth installation.
4. 48mm-58mm 48mm-58mm
Long Screw
Lubricant
Small Leak-proof Gasket
Inlet Pipe
Drainage Pipe
Big Leak-proof Gasket
5. Install the toilet as shown in the illustration, and use a spirit
level to ensure the lavatory to remain level.
5.
Spirit Level
2.
Inlet Pipe
Reserved Space
Drainage Pipe
2. Eliminate unwanted part of the inlet pipe according to themarks of reserved space ,and rasp a smooth surface withfiles.
1288818-T01-A
-13-
E. Faceplate Installation
E.
1.
1. OPEN
When tighten four locknuts on supporting board, adjust to
"OPEN" mark as shown.
Supporting Board
Locknut
2. Tighten four screws to "LOCK" mark after installing
supporting board as shown.
2. LOCK
Gasket
Long Screw
Reversed Lock
Hexagonal Nut
Decoration Cap
6. Install the reserved lock, gasket, hexagonal nut anddecoration cap onto long screw according to the ordershown in the illustration.
Please refer to the installation instructions of toilet.Note:
6.
3. Install the big flush air hose and small flush air hose to thecover.
Cut the excessive parts of the air hose if necessary andfix it onto the tank fastener.
Put the lock on the cover directly on the reversedlock on supporting board, then push the cover and lock it.The installation shall begin from bottom to top.
Note:
3.
Faceplate
Lock
Faceplate
SupportingBoard
Connect to air hoseFastener
1288818-T01-A
-14-
2. Make sure of h according to dimensions of bowl and then
locate the installation hole of fixing bracket. Mark on the
wall for appropriate position for fixing bracket, and drill four
holes with diameter of 10mm and depth of 80mm with
churn drilling as shown in illustration, and fill in the holes
with bulge screw and tighten the screw to set the fixing
bracket.
Note: Ensure the fixing bracket to remain level.
2. h
10mm 80mmO
Fixing Bracket
Bulge Screw
Gasket
Spring
Nut
Installation For In-wall Tank Without Frame
A. Installation of In-wall TankA.
4. It is ready to use when connected to water supply afterinstallation.
Reserve access panel at front or top of the tank inremote installation.Note:
4.
Half Flush Button
Full FlushButton
h
1. Remove in-wall tank from packing box. Remove front coverboard or top cover board inside water tank first as shown.Then remove support block and plug above bracketassembly.
1.
Cover,Top
Cover,Front
Plug Cover,Top
Cover,Front
Supporting Board
1288818-T01-A
-15-
3. Put the tank onto the fixing bracket as shown in the right
figure and adjust the tank to level . Then tighten screws
with hex-head key.
it is a must to keep the tank level.Note:
3.
Screw
Level
Tank
TightenLoosen
MediumAllen Key
4. Connect with overflow pipe on the side when installing
K-78073K-PNE/K-78075K-PNE.
4. K-78073K-PNE/K-78075K-PNE
Overflow Pipe
5. Connect tap water braided tube on the top of water tank forwater supply as shown.
Note: 1. Ensure water tank internal valve is OFF.2. Suggestion: connect a temporary rubber or plastic
hose on valve, flush water supply pipeline. Ensurewater is clean, no residual sand stone or foulinginside pipeline.
5.
1.
2.
Water Pipe
Connecting Pipe
6. Access Panel Installation Methods:
There are four ways to install access panel:
Method one: Press from top
Method two: Remote plate installation: fix four plates with
screws
Method three: Remote installation of mask
Method four: Press from front: fix four plates with screws
6.
:
Method one:Press from top
Method four:Press from front
Method two:Remote plate installation
Method three:Remote installation
of mask
Air hose
Air hose
Air hose
Pinchplate
Pinch plate
Suggested faceplateinstallation area
R1000mm
Suggested faceplateinstallation area
R1000mm
Finished wall
23~
72
At least80mm gapreserved
80mm
1288818-T01-A
-16-
2) Cut apart the cable of the air hose and pull it out from
the rectangle cover.
2)
7. Method one: Install mask when pressing from top
1) Remove top plate, then install the mask on the top of the
tank, and tighten the screw to fix the mask to the tank.
7.
1)
Cover,Top
Screw
Mask
Cable
Cover,Top
Cover,Front
8. Methods two and three: During remote installation, fix the
cover onto the tank and pull the air hose to the panel.
Reserve access panel at front or top to ensure removal
and installation of cover.
Method two: During remote plate installation, 7~20mmthickness is recommended for the wall of the pinch plateand at least 80mm gap is reserved.Method three: During remote installation of mask, 4 holeswith diameter of 10mm and depth of 16mm are needed tobe reserved at the locating hose. Drill 10mm holes throughair hose on the side of the mask.
8.
7~20mm 80mm
4
10mm 16mm 10mm
At least 80mm gap reserved80mm
Air hose
Pinch plate
Finished wall
SupportingBoard
Air hose
Finishedwall
72
7~20mm recommended7~20mm
10 Hole through hose
10
10 Depth 16,Space reserved10 16
1288818-T01-A
10. Insert the inlet pipe and drainage pipe into the bowl, andthen adjust the syphon and drainage pipe to a properposition to be fixed into the bowl. Make sure of thepositions of syphon and discharge elbow and thenremove the bowl.
10.
Inlet Pipe
Syphon
Discharge Elbow Drainage Pipe
-17-
Pinch plate installation
Screw
Air hose
Pinch platePinch plate
Finished wall
Faceplate
Supporting Board
9. Method four: Cut apart the cable of the air hose. Pull it outfrom the front of the tank and meanwhile reserve theaccess panel. Fix the four plates with screws and then fixthe support board.
No direct contact between the faceplate and the tank.7~20mm thickness recommended for the wall of thepinch plate.
Note:
9.
7~20mm
Method four:Press from front
Air hose
Pinch plate
Finished wall
7~20mm recommended7~20mm
At least 80mm gap reserved80mm
At least80mm gapreserved
80mm
1288818-T01-A
-18-
12. Fix faceplate according to step E and then it is ready for
use.
Reserve access panel at front or top of the tank in
remote installation.
Note:
12. E
Half Flush Button
FullFlush Button
Finished Installation Illustration
11. When finishing the brickwork, eliminate unwanted part ofthe mask, the drainage pipe and the inlet pipe, if there ismask.
11. Inlet Pipe
Drainage Pipe
1.
1. Remove the air hoses of the big flush and small flush.
Then remove the faceplate.
REMOVE AND MAINTENANCE OF THE OUTLET VALVEREMOVE AND MAINTENANCE OF THE OUTLET VALVE
Faceplate
Faceplate
Connect to air hose
Mask
1288818-T01-A
-19-
3. Dismantle supporting board as shown.
3.
2. Pay special attention when dismantle supporting board 4lock nuts, all bolts shall align with "OPEN" mark.
2. OPEN
5. Unscrew the nut of the metal weaved hose and push theconnector of the inlet valve as shown to remove the inletvalve.
5.
4. Open/close water supply
Rotate valve switch to open/close water supply as shown.
4.
Valve
Close
Open
Conntector,Quick release
Metal weaved hose nut
Supporting Board
Locknut
1288818-T01-A
-20-
Fastener
Fastener
8. Hold fastener by hand as shown, pull the top of fastener
along the direction of arrow. Then remove fastener.
8.
6. Push aside the snap of the toilet detergent box to take thebox out.
6.Snap
7. Push aside the pivot snaps of the big flush and small flushtowards upper right to make the lever and pivot apart. Holdbracket top by hand and then lift up to unlock the bracket.
Push aside the pivot snaps of the big flush and smallflush towards lower left to fix back the bracket. Lock the snap.Note:
7.
Lever Snap
Snap (Locked)( )
9. Pull discharge valve along the arrow direction as shown toremove discharge valve.
9.
Outlet Valve
1288818-T01-A
-21-
10. Remove discharge valve as shown and then take valveout for cleaning or adjusting.
10.
Outlet Valve
Outlet Valve
B.
(1)(2)
Floating Box
Drainage valveAdjustment Switch
B. Adjust Drainage Valve
Drainage volume and overflow level of the tank can beadjusted by drainage valve:1) heavy drainage adjustment:open adjustment switch to open the small hole. 2) slightdrainage adjustment: adjust the height of floating box andthe water level of slight drainage will be at the bottom ofthe floating box.
A Wash Filtration Net
Close corner valve first, then loosen and take out the tightennut, and wash the waste on filtration net with clean water.Then reset the tighten nut to the original position.
.
A.
Tighten
Close
Open
Corner
Open
A
Tighten
Close
C
Filtration Net
B
Press for Top
1288818-T01-A
-22-
TROUBLE SHOOTING PROCEDURESTROUBLE SHOOTING PROCEDURES
No water fills in via inletvalve
The inlet valve is closed. Open inlet valve.
Floating box of inlet valve is blocked by other parts.
Floating box of inlet valve is block by waste. Wash the floating box with clean water.
The air hose and faceplate are wrongly installed. Reinstall the air hose.No drainage whenpressing the heavy andslight drainage button
Too high or too low waterlevel
Leak of the toilet andsquat
Toilet does not flush
Toilet does not flushcompletely
Symptoms Probable Causes Recommended Action
The pole and the reversed lock are not connected. Reinstall the reversed lock onto the pole ofthe outlet valve.
The floating box of the inlet valve is not properlyadjusted.
Readjust the water level.
The floating box of the inlet valve is blocked bywastes, so the water is leaked from the overflowpipe.
A. No water supply.B. The water supply stop is closed.
Readjust the position of other parts to avoidcontacting the floating box when it isfunctioning.
A. Wait for restoration of water supply.B. Open the water supply stop.
Readjust the position of other parts to avoidcontacting the floating box when it isfunctioning.
The rubber gasket is blocked by wastes.
Filter screen is clogged.
Take out the outlet valve and clean thewastes.
Refer to wash filtration net.
C.
Control Pole
Inlet Valve
Floating Box
C. Adjust Inlet Valve
Hoist and reduce the water level in the tank by adjusting
the control pole. Turn the control pole counterclockwise to
lower down the floating box and reduce the water level of
the tank .turn the control pole clockwise to hoist the
floating box and increase the water level in the tank.
1288818-T01-A
A.B.
A.B.
-23-1288818-T01-A