hydro power plants. tail water draft tube gate draft tube turbine main valve penstock air inlet...

73
Hydro power plants

Upload: alexander-gaines

Post on 18-Dec-2015

227 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Hydro power plants

Page 2: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Hydro power plants

Tail water

Draft tube gate

Draft tube

TurbineMain valve

Penstock

Air inletInlet gate

Surge shaft

TunnelSand trap

Trash rack

Self closing valve

Page 3: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

The principle the water conduits of a traditional high head power plant

Page 4: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Ulla- Førre

Original figur ved Statkraft Vestlandsverkene

Page 5: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Intake gate

Intake trashrack

Headrace tunnel

Anchor block

Surge tank

Penstock inletValve

Tunnel Inlettrashrack

Tunnel Inlet

Anchor block

Exp. joint

Shaddle

Power house

TailraceIV G

SC

DTR

DT end gate

Desilting basin

gate hoist

IV -inlet valveR -turbine runnerSC -spiral caseG -generator

Typical Power House with Francis Turbine

Page 6: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Arrangement of a small hydropower plant

Page 7: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

H = 39 mQ = 513 m3/sP = 182 MWDrunner=7,5 m

Ligga Power Plant, Norrbotten, Sweden

Page 8: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Borcha Power Plant, Turkey

H = 87,5 mP = 150 MWDrunner=5,5 m

Page 9: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Water intake

• Dam• Coarse trash rack• Intake gate • Sediment settling basement

Page 10: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Dams• Rockfill dams

• Pilar og platedammer

• Hvelvdammer

Page 11: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Rock-fill dams

1. Core Moraine, crushed soft rock, concrete, asphalt2. Filter zone Sandy gravel3. Transition zone Fine blasted rock4. Supporting shell Blasted rock

Page 12: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Slab concrete dam

Page 13: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Arc dam

Page 14: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Gates in Hydro Power Plants

Page 15: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Types of Gates

• Radial Gates

• Wheel Gates

• Slide Gates

• Flap Gates

• Rubber Gates

Page 16: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Radial Gates at Älvkarleby, Sweden

Page 17: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Radial Gate

The forces acting on the arc will be transferred to the bearing

Page 18: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Slide Gate

Jhimruk Power Plant, Nepal

Page 19: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Flap Gate

Page 20: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Rubber gate

Reinforced rubberOpen position

Flow disturbance

Reinforced rubberClosed position Bracket

Air inlet

Page 21: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Circular gate

ManholeHinge

Ladder

RibsPipe

End cover

Bolt

Fastening element

Frame Seal

Page 22: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Circular gate

Jhimruk Power Plant, Nepal

Page 23: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Trash Racks

Panauti Power Plant, Nepal

Page 24: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Theun Hinboun Power PlantLaos

Page 25: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

GravfossPower PlantNorway

Trash Rack size:Width: 12 meterHeight: 13 meter

Stainless Steel

Page 26: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

CompRack Trash Rack delivered by VA-Tech

Page 27: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Cleaning the trash rack

Page 28: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Pipes• Materials• Calculation of the change of length due to the

change of the temperature• Calculation of the head loss• Calculation of maximum pressure

– Static pressure– Water hammer

• Calculation of the pipe thickness• Calculation of the economical correct diameter• Calculation of the forces acting on the anchors

Page 29: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Materials

• Steel

• Polyethylene, PE

• Glass-fibre reinforced Unsaturated Polyesterplastic , GUP

• Wood

• Concrete

Page 30: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

MaterialsMaterial Max.

DiameterMax.

PressureMax.

Stresses

[m] [m] [MPa]

Steel, St.37 150

Steel, St.42 190

Steel, St.52 206

PE ~ 1,0 160 5

GUP 2,4Max. p = 160 m.

320Max. D: 1,4 m.

Wood ~5 80

Concrete ~5 ~ 400

Page 31: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Steel pipes in penstockNore Power Plant, Norway

Page 32: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

GUP-PipeRaubergfossen Power Plant, Norway

Page 33: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Wood Pipes

Breivikbotn Power Plant, Norway Øvre Porsa Power Plant, Norway

Page 34: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the change of length due to the change of the temperature

LTL Where:L = Change of length [m]

L = Length [m] = Coefficient of thermal expansion [m/oC m]T = Change of temperature [oC]

Page 35: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the head loss

g2

c

D

Lfh

2

f

Where:hf = Head loss [m]f = Friction factor [ - ]L = Length of pipe [m]D = Diameter of the pipe [m]

c = Water velocity [m/s]g = Gravity [m/s2]

Page 36: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self
Page 37: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the head loss

Dc

Re

Power Plant data:H = 100 m HeadQ = 10 m3/s Flow Rate

L = 1000 m Length of pipeD = 2,0 m Diameter of the pipeThe pipe material is steel

Where:c = 3,2 m/s Water velocity = 1,308·10-6 m2/s Kinetic viscosityRe = 4,9 ·106 Reynolds number

g2

c

D

Lfh

2

f

Page 38: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

0,013

Where:Re = 4,9 ·106 Reynolds number = 0,045 mm RoughnessD = 2,0 m Diameter of the pipe/D = 2,25 ·10-5 Relative roughness

f = 0,013 Friction factorThe pipe material is steel

Page 39: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the head loss

Power Plant data:H = 100 m HeadQ = 10 m3/s Flow Rate

L = 1000 m Length of pipeD = 2,0 m Diameter of the pipeThe pipe material is steel

Where:f = 0,013 Friction factorc = 3,2 m/s Water velocityg = 9,82 m/s2 Gravity

m4,382,92

2,3

2

1000013,0

g2

c

D

Lfh

22

f

Page 40: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of maximum pressure

• Static head, Hgr (Gross Head)

• Water hammer, hwh

• Deflection between pipe supports

• Friction in the axial direction

Hg

r

Page 41: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Maximum pressure rise due to the Water Hammer

c

g

cah max

wh

hwh = Pressure rise due to water hammer [mWC]a = Speed of sound in the penstock [m/s]cmax = maximum velocity [m/s]

g = gravity [m/s2]

Jowkowskya

L2TIF C

Page 42: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Example Jowkowsky

c=10 m/s

m1020g

cah max

wh

a = 1000 [m/s]cmax = 10 [m/s]

g = 9,81 [m/s2]

a

L2TC

Page 43: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Maximum pressure rise due to the Water Hammer

C

max

C

maxwh Tg

L2c

Ta

L2

g

cah

Where:hwh = Pressure rise due to water hammer [mWC]a = Speed of sound in the penstock [m/s]cmax = maximum velocity [m/s]

g = gravity [m/s2]L = Length [m]TC = Time to close the main valve or guide vanes [s]

L

C

a

L2TIF C

Page 44: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Example

m61Tg

L2ch

C

maxwh

L = 300 [m]TC = 10 [s]cmax = 10 [m/s]

g = 9,81 [m/s2]

L

C=10 m/s

Page 45: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the pipe thickness

t

Crp

tL2CpDL

sit

tsi

whgr hHgp Where:

L = Length of the pipe [m]Di = Inner diameter of the pipe [m]p = Pressure inside the pipe [Pa]t = Stresses in the pipe material [Pa]t = Thickness of the pipe [m]Cs = Coefficient of safety [ - ] = Density of the water [kg/m3]Hgr = Gross Head [m]hwh = Pressure rise due to water hammer [m]

ri

t

pt t

• Based on:– Material properties – Pressure from:

• Water hammer• Static head

Page 46: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the pipe thickness

m009,0Crp

t

tL2CpDL

t

si

tsi

MPa57,1hHgp whgr

Where:L = 0,001 m Length of the pipeDi = 2,0 m Inner diameter of the pipet = 206 MPa Stresses in the pipe material = 1000 kg/m3 Density of the waterCs = 1,2 Coefficient of safetyHgr = 100 m Gross Headhwh = 61 m Pressure rise due to water hammer

ri

t

pt t

• Based on:– Material properties – Pressure from:

• Water hammer• Static head

Page 47: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the economical correct diameter of the pipe

Diameter [m]

Cos

t [$]

Installation costs, Kt

Costs for hydraulic losses, Kf

Total costs, K tot

0

dD

KKd

dD

dK tftot

Page 48: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

Hydraulic Losses

Where:PLoss = Loss of power due to the head loss [W] = Density of the water [kg/m3]g = gravity [m/s2]Q = Flow rate [m3/s]hf = Head loss [m]f = Friction factor [ - ]L = Length of pipe [m]r = Radius of the pipe [m]C2 = Calculation coefficient

52

42

2

fLoss r

C

rg2

Q

r2

LfQghQgP

Power Plant data:H = 100 m HeadQ = 10 m3/s Flow Rateplant = 85 % Plant efficiency

L = 1000 m Length of pipe

Page 49: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

Cost of the Hydraulic Losses per year

Where:Kf = Cost for the hydraulic losses [€]PLoss = Loss of power due to the head loss [W]T = Energy production time [h/year]kWhprice = Energy price [€/kWh]r = Radius of the pipe [m]C2 = Calculation coefficient

price52

priceLossf kWhTr

CkWhTPK

Page 50: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

Present value of the Hydraulic Losses per year

price52

f kWhTr

CK

Where:Kf = Cost for the hydraulic losses [€]T = Energy production time [h/year]kWhprice = Energy price [€/kWh]r = Radius of the pipe [m]C2 = Calculation coefficient

Present value for 20 year of operation:

n

1ii

fpvf

I1

KK

Where:Kf pv = Present value of the hydraulic losses [€]n = Lifetime, (Number of year ) [-]I = Interest rate [-]

Page 51: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

Cost for the Pipe Material

21mmm rCL

rpr2Ltr2Vm

Where:m = Mass of the pipe [kg]

m = Density of the material [kg/m3]V = Volume of material [m3]r = Radius of pipe [m]L = Length of pipe [m]p = Pressure in the pipe [MPa]

= Maximum stress [MPa]C1 = Calculation coefficientKt = Installation costs [€]M = Cost for the material [€/kg]

21t rCMmMK

NB:This is a simplification because no other component then the pipe is calculated

Page 52: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

• Installation Costs:– Pipes– Maintenance– Interests– Etc.

Page 53: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

21t rCMK

Where:Kf = Cost for the hydraulic losses [€]Kt = Installation costs [€]T = Energy production time [h/year]kWhprice = Energy price [€/kWh]r = Radius of the pipe [m]C1 = Calculation coefficientC2 = Calculation coefficientM = Cost for the material [€/kg]n = Lifetime, (Number of year ) [-]I = Interest rate [-]

n

1ii

price52

pvfI1

kWhTrC

K

0I1

kWhTC

r

5rCM2

dr

KKd n

1ii

price2

6ft

Page 54: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

ExampleCalculation of the economical correct diameter of the pipe

7

n

1ii

price2

n

1ii

price2

6ft

I1CM

kWhTC

2

5r

0I1

kWhTC

r

5rCM2

dr

KKd

Page 55: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the forces acting on the anchors

Page 56: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the forces acting on the anchors

F5

F4F3

F1

F2

F

F1 = Force due to the water pressure [N]F2 = Force due to the water pressure [N]F3 = Friction force due to the pillars upstream the anchor [N]F4 = Friction force due to the expansion joint upstream the anchor [N]F5 = Friction force due to the expansion joint downstream the anchor [N]

Page 57: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Calculation of the forces acting on the anchors

G

F

R

Page 58: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Valves

Page 59: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Principle drawings of valvesOpen positionClosed position

Spherical valve Gate valve

Hollow-jet valve Butterfly valve

Page 60: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Spherical valve

Page 61: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Bypass system

Page 62: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Butterfly valve

Page 63: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Butterfly valve

Page 64: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Butterfly valvedisk types

Page 65: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Hollow-jet Valve

Page 66: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Pelton turbines

• Large heads (from 100 meter to 1800 meter)

• Relatively small flow rate

• Maximum of 6 nozzles

• Good efficiency over a vide range

Page 67: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Kværner

Jostedal, Norway

*Q = 28,5 m3/s*H = 1130 m*P = 288 MW

Page 68: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Francis turbines

• Heads between 15 and 700 meter

• Medium Flow Rates• Good efficiency

=0.96 for modern machines

Page 69: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

SVARTISEN

P = 350 MWH = 543 mQ* = 71,5 m3/SD0 = 4,86 mD1 = 4,31mD2 = 2,35 mB0 = 0,28 mn = 333 rpm

Page 70: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self
Page 71: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self
Page 72: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self

Kaplan turbines

• Low head (from 70 meter and down to 5 meter)

• Large flow rates • The runner vanes can

be governed • Good efficiency over

a vide range

Page 73: Hydro power plants. Tail water Draft tube gate Draft tube Turbine Main valve Penstock Air inlet Inlet gate Surge shaft Tunnel Sand trap Trash rack Self