hydra-point™ volumetric karl fischer reagents · pdf filefor stabilizing the ph during...
TRANSCRIPT
P R O D U C T P R O F I L E | www.avantormaterials.com | 1
Productprofile
Pyridine-free for safe, easy H2o determination
The product line with all the right components
No matter what your requirements are for volumetric systems,
HYDRA-POINT Karl Fischer reagents make water determination
easy and trouble free. They are pyridine-free and specially
formulated for existing application procedures to give you
consistent, reliable results for all types of samples. Key features
of HYDRA-POINT reagents are:
• (Pyridine-free)—The use of pyridine in the laboratory has
well recognized hazards, in addition to its unpleasant odor.
That is why our HYDRA-POINT products do not contain
pyridine.
• Productivity—HYDRA-POINT reagents are formulated
to reach each endpoint quickly, accurately, and with
reproducibility, allowing you to perform more titrations in
less time.
• Accuracy—Comparison studies prove HYDRA-POINT
reagents have titers that are more stable with less drift,
helping you save time and reduce reagent usage.
HYDRA-POINT titrants and solvents guarantee fast
equilibration within the Karl Fischer reaction vessel, giving
greater laboratory efficiency and speed of analysis.
two-comPonent Hydra-Point Karl fiscHer reagents
With two-component reagents, the reactants are in two
separate solutions. The burette is filled with HYDRA-POINT
titrant and the reaction vessel contains HYDRA-POINT solvent.
First, the HYDRA-POINT solvent is titrated to dryness with
HYDRA-POINT titrant. Then the sample is added and the water
content is analyzed by titration.
8855 HYDRA-POINT Solvent G:
Pyridine-free solvent component for volumetric Karl Fischer
titration (use with product 8844 and 8845).
8844 HYDRA-POINT Titrant 5:
Titrant component (5 mg H2O per mL) for volumetric Karl
Fischer titration (use with product 8840 or 8855).
8845 HYDRA-POINT Titrant 2:
Titrant component (2 mg H2O per mL) for volumetric Karl
Fischer titration (use with product 8840 or 8855).
one-comPonent Hydra-Point Karl fiscHer reagents
In one-component systems, all the reactants are present in
the HYDRA-POINT composite reagent. The sample is put into
a methanol solution in the titration vessel. Then the HYDRA-
POINT composite is titrated into the titration vessel until the
endpoint is reached.
8890 HYDRA-POINT Composite 5:
Pyridine-free, one-component reagent (5 mg H2O per mL) for
volumetric Karl Fischer titration.
HYDRA-POINT™ Volumetric Karl Fischer Reagents
8891 HYDRA-POINT Composite 2:
Pyridine-free, one-component reagent (2 mg H2O per mL) for
volumetric Karl Fischer titration.
8892 HYDRA-POINT Composite 5K:
Pyridine-free, one component reagent for volumetric Karl
Fischer titration of ketones (use with product 8898).
more quality Hydra-Point Karl fiscHer Products from J.t.BaKer
8899 HYDRA-POINT Buffer:
For stabilizing the pH during Karl Fischer titration. The buffer
capacity is 5 mmol acid per mL.
8898 HYDRA-POINT Dry Methanol:
Dry methanol (water max. 0.01%) for Karl Fischer titration.
For more detailed information, prices and ordering, please
contact your local distributor or our Customer Service
department.
Phillipsburg, NJ 9001: 2008 & 14001: 2004Paris, KY 9001: 2008Mexico City, Mexico 9001: 2008Deventer, the Netherlands 9001: 2008 & 14001: 2004 & 13485: 2003Selangor, Malaysia 9001: 2008
Ordering Information and AssistanceCustomer Service and Technical Servicetoll free: +1-855-AVANTOR (+1-855-282-6867)outside of u.s. tel: +1-610-573-2600fax: +1-610-573-2610 e-mail: [email protected] www.avantormaterials.com
AskAvantor™Our Web site features ASK Avantor,™ which includes live chat capabilities with customer service representatives. www.avantormaterials.com/askavantor
Corporate HeadquartersAvantor Performance Materials, Inc. 3477 Corporate Parkway Suite #200 Center Valley, PA 18034 USA
About Avantor™ Performance MaterialsAvantor Performance Materials manufactures and markets high-performance chemistries and materials around the world under several respected brand names, including the J.T.Baker®, Macron Fine Chemicals™, Rankem™, Diagnova™, BeneSphera™, and POCH™ brands.
Avantor products are used in a wide range of industries. Our biomedical and life science solutions are used in academic, industry and quality control laboratories for research, pharmaceutical production and medical lab testing, while our electronics solutions are used in the manufacturing of semiconductors and flat panel displays. Based in Center Valley, Pennsylvania (USA), Avantor is owned by an affiliate of New Mountain Capital, LLC.
For additional information please visit www.avantormaterials.com or follow www.twitter.com/avantor_news
Lit Number: 9002 ©2012 Avantor Performance Materials, Inc. All rights reserved. Trademarks are owned by Avantor Performance Materials, Inc. or its affiliates unless otherwise noted.
Worldwide Locations• China • Malaysia • North America• India • Mexico • Taiwan• Korea • The NetherlandsFor contact information at these locations, visit www.avantormaterials.com/Support/Contact-Us/Worldwide-Directory.aspx