Page 1: HVF 38 kV Circuit Breaker - 04112018 - Myers Power1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1. Gear Box 2. Manual Charging Port 3. Link 4. Closing Spring 5. Spring Charge Motor

HVF38HVF 38kV Vacuum Circuit Breaker

Page 2: HVF 38 kV Circuit Breaker - 04112018 - Myers Power1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1. Gear Box 2. Manual Charging Port 3. Link 4. Closing Spring 5. Spring Charge Motor

High Reliability, Long Life

Circuit Breaker Features

38kV Switchgear Features

Low Maintenance• Robust design and rugged compo-

nents increase durability and reduce maintenance

• Back-to-back capacitor switching of 90 MVAR (28kV), far exceeding of ANSI standards

Myers Power Products HVF series vacuum circuit breakers are offered in 1200A, 2000A, 2500A, and 3000A (fan cooled) continuous current. These breakers are designed and manufactured with advanced vacuum technology. They have been tested according to the latest version of ANSI standards in ISO 9001 facilities, and are continuously improved to meet the evolving demands of the market. Myers 38kV breakers are backed by nearly 40 years of switchgear manufacturing expe-rience and have a long record of reliable performance for hundreds of utility, industrial, and transit customers.

• Offered in 31.5kA and 40kA interrupting ratings, allowing you to purchase only the capacity you need

• Self-aligning, self-coupling secondary disconnects ensure positive connection of relay circuits to circuit breaker trip coil

• Secondary disconnects are the most robust in the industry• Heavy-duty utility grade contacts eliminate the need for manual connection of a

plug and socket or umbilical cord• Optional indicator shows breaker position when door is closed• High speed option available

• 10 year lubrication interval• 5 year routine inspection• Service required only on parts sub-

ject to normal wear and aging

• Compact 42 inch wide enclosure• Enclosure accommodates drawout CPTs (up to 15kVA) and drawout PTs above

circuit breaker, reducing lineup length• Closed door racking available• Remote trip/close available• Electric remote racking device available• Manual or electric ground and test device options

Type No. Application StandardRated Voltage (kV)Rated Current (A)Rated Interrupting Current (kA)Rated Close & Latch (kA) Frequency (Hz) Rated Low Freq.Withstand (kV, RMS) Impulse Withstand Vltg. (kV, BIL) Breaking Time (cycles) Operating Duty Operating Life at Rated Current (Times) Closing Operation Operation system Control Voltage Closing & Tripping - Control VoltageAuxiliary ContactsMain Body Weight (Lbs.)

HVF705ANSI C37.06 / ANSI C37.09381200, 2000, 2500, 300031.5 or 4082 or 10460801705 cycles with opt. three cycles available0 -0.3s-CO-3min-CO20,000Motor Spring Stored EnergyDC 48, 110, 125, 220; AC 120, 220DC 48, 110, 125, 220; AC 120, 2204NO + 4NC (Max. 10NO + 10NC)M1200A 750 / 2000A 800 / 2500A 850 / 3000A 850

All circuit breaker ratings are based on K = 1.0

Myers Power Products can retrofi t any of your existing Oil, Vacuum, SF-6, Air Magnetic, or Air Blast circuit breakers with our new modern Type HVF Vacuum Breaker and extend the life of your equipment. Call us today to learn more.

38kV Circuit Breaker Retrofi ts

Three Pole Drawout Units For Use In 38Kv Switchgear For New or Retrofi t Installation

Ratings & Additional Products Description

Page 3: HVF 38 kV Circuit Breaker - 04112018 - Myers Power1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1. Gear Box 2. Manual Charging Port 3. Link 4. Closing Spring 5. Spring Charge Motor

Current Consumption 38Kv Switchgear Dimensions

38Kv Cell Interior

• Self-aligning, self-coupling secondaries — no manual plug & socket connection required

• Grounded metal shutters• Separate disconnect, test, and connected positions• Full set of ANSI interlocks• Rugged construction

RatedVoltage (V)

Current Consumption (A)

Motor Closing Solenoid Open Solenoid

48 DC 10.5 2.7 2.7110 DC 4.5 1.3 1.3125 DC 4.5 1.5 1.5220 DC 2.3 0.65 0.65120 AC 6.4 1.3 1.3

Nominal Dimensions

Width 42 inchesHeight 110 inchesDepth Indoor: 148 inches

Outdoor, Non Walk In: 152 inches

Outdoor Protected Aisle: 20 Feet

Outdoor Common Aisle: 33 feet

Manual Close Button

Manual Open ButtonCharge IndicatorClose / Open Indicator

Counter

Manual Charging Port

• Drawout potential transformers can be mounted above a circuit breaker• Drawout control power transformers (up to 15kVA) can be mounted above circuit

breaker• Space saving design reduces installation footprint

HVF705ANSI C37.06 / ANSI C37.09381200, 2000, 2500, 300031.5 or 4082 or 10460801705 cycles with opt. three cycles available0 -0.3s-CO-3min-CO20,000Motor Spring Stored EnergyDC 48, 110, 125, 220; AC 120, 220DC 48, 110, 125, 220; AC 120, 2204NO + 4NC (Max. 10NO + 10NC)M1200A 750 / 2000A 800 / 2500A 850 / 3000A 850

Typical Breaker Elements

Page 4: HVF 38 kV Circuit Breaker - 04112018 - Myers Power1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1. Gear Box 2. Manual Charging Port 3. Link 4. Closing Spring 5. Spring Charge Motor

1

23

45

678

9

1011

12

1314

1516

17

18

19

1. Gear Box2. Manual Charging Port3. Link4. Closing Spring5. Spring Charge Motor6. Tripping Spring7. Spring Charged Indicator8. Limit Switch (S21, S22, S3)9. Open / Closed Indicator10. Dash Pot11. Operations Counter12. Operating Mechanism Enclosure13. Auxiliary Switch (S1)14. Manual Close Button15. Closing Solenoid (Y9)16. Tripping Solenoid (Y1)17. Manual Open Button18. Coupling Bar19. Breaker Shaft

Y1

5

4

8

3

2

M1

S22

S21

1

S3

7

K1

S1

K1

Y9

K1

S3

6

S1

11

12

9

10 16 14

1315

20 18

19 17

24

23

22

21

2 7 5 8 12 10 16 14 20 1824 22

1 6 4 3 11 9 15 1913 1723 21

TRIP

CO

IL

X0

X0

CON

TAC

TSBR

EAKE

R AU

XILI

ARY

MO

TOR

OPE

RATE

D

CLO

SIN

G S

OLE

NO

ID

(SH

UN

T RE

LEA

SE)

AN

TI-P

UM

PIN

G R

ELAY

MEC

HA

NIS

M

COIL

SIG

NA

LSP

RIN

G C

HA

RGE

21

22

22

21

A1

A2

13

1421

22 61

62

8

7

4

6

1

5

A1

A2

K1CONTACTUNIT 53

54

A1

A2

CPLLCTERMINALS (BY CPLLC)

BKR SECONDARYPLUG CONNECTOR

TERMINALS (BY CPLLC)CPLLC

19

10 21

22 24

23

34

33

32

31

42

41

44

43

52

51

64

63

(BY HYUNDAI)

(BY HYUNDAI)

BKR SECONDARYPLUG CONNECTOR

BKR CELLRECEPTACLE(BY HYUNDAI)

BKR CELLRECEPTACLE(BY HYUNDAI)

13

14

EC-5

EC-4

EC-8

EC-3

EC-2

EC-1

EC-7

EC-6

T6 T1

T5

T8

T7

EC-11

EC-12

EC-9

EC-10 ED-4 ED-2

ED-3 ED-1

ED-8 ED-6

ED-7 ED-5 ED-9

ED-10ED-12

ED-11

LEGEND

M1 CHARGING MOTOR 52CC CLOSING OLENOID S AUXILIARY SWITCH

LS1, LS2, LS3 LIMIT SWITCH 52TC TRIPPING OLENOID R1 RESISTOR

XO PLUG/SOCKET Y ANTI PUMPING RELAY R2 RESISTOR

Description of HVF Vacuum Circuit Breaker

Typical Circuit Diagram

Specifi cations are subject to change without notice.

0411

2018

www.myerspowerproducts.com | (866) MY-MYERS