hush booths for medical applica tions

15
HUSH BOOTHS FOR MEDICAL APPLICATIONS

Upload: others

Post on 30-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

HUSH BOOTHSFOR MEDICALAPPLICATIONS

Page 2: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

HUSHOFFICE PODS RANGE

hushphone

COMFORTABLE PHONE CALLS

Up to one person

hushwork

INDIVIDUAL WORK

Up to one person

hushtwin

INDIVIDUAL WORK

Up to two people

hushmeet.open

INFORMAL MEETINGS

Up to four people

hushmeet

PRIVATE MEETINGS

Up to four people

FORMAL MEETINGS

hushmeet.L

Up to eight people

Page 3: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

CHOOSE THE APPLICATION OF THE PRODUCT

CHOOSE THE SHAPE

OF THE CABIN

DEFINE THE LEVEL OF

ANTI-MICROBIAL PROTECTION

DEFINE NECESSARY

MODIFICATIONS

OUR ENGENEERS WILL DESIGN

THE FINAL PROJECT

MANUFACTURE & DELIVERY

STAGE

HUSH FOR MEDICAL APPLICATION – DESIGN&MANUFACTURE PROCESS

Page 4: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

Our booths are multifunctional. We start our process by defining the destination of the product. It helps to choose the most suitable product from the hushoffice offer.

EXAMPLES: telemedicine, relax/nap room, examination room, breast feeding room.

CHOOSE THE SHAPE OF THE CABIN

hushwork.sit&stand

1600x2300x1200 mm 63x91x47 in

Weight 445 kg/981 lbsTable 960x530 mm/981 lbs

hushwork

1600x2300x1200 mmWeight 425 kg

Table 960x530 mm

hushmeet

2150x2300x1390 mm 85x91x56 in

Weight 660 kg/1455 lbs

hushmeet.L

2600x2300x1800-3600 mm102x90x71-142 in

Weight 775-1470 kg/1709-3241 lbs

hushphone

1000x2230x900 mm 39x88x35 in

Weight 320 kg/705 lbs

CHOOSE THE APPLICATION OF THE PRODUCT

Page 5: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

DEFINE THE LEVEL OF ANTI-MICROBIAL PROTECTION

Easy to clean anti-microbial upholstery inside the Hush pods improves the hygiene and takes care about users health.

• Anti-bacterial • Bacterial resistance (AATCC TM 147)• Anti-static (ASTM D-257)• Mildew resistance

2 VINYL CARPET

High performance and technical capabilities such as extreme durability, as well as superior wear, stain and abrasion resistance. Simple dry-buffing is all you need to restore this floor’s original appearance.

• Ease of decontamination „Excellent” due to ISO 8690 – DIN 25415

• Bacteria resistance „Does not favour growth” due to ISO 846:Part C

• Chemical resistance “Excellent” due to ISO 26987

ABRASION RESISTANT

IMPERMEABILITY UV RESISTANT FLAME RETARDANT

MILDEW RESISTANT

LOW TEMP. RESISTANT

EASY TO CLEAN

REACTION TO FIRE

OPTIMAL INDOORAIR QUALITY

PHTHALATE FREE

LIGHT FASTNESS

SLIP RESISTANCE

RECYCLABLE – 100%

1 VINYL UPHOLSTERY

Page 6: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

HO

O2

H2O2

HO2

DEFINE THE LEVEL OF ANTI-MICROBIAL PROTECTION

Photocatalytic nano coating is a system of antibacterial and antiviral photocata-

lytic coatings, based on a unique chemical solution. The system uses the light as

a catalyst for carbon dioxide to have disinfectant features. The constant process

of disinfection lasts for minimum of 12 months. During this time free radicals

and hydrogen peroxide are produced on the surface of the coating and they kill

bacteria, viruses and other pathogens, by turning them into harmless CO2 and

H2O. This solution is much more effective than antibacterial coatings containing

silver, which kill bacterium but do not decompose its body and the endotoxins,

which stay on the surface and constitute a nutrient medium for pathogens.

3 NANO-COATING PROTECTION

VIRUSES

BACTERIA

ORGANIC CONTAMINANTS

Page 7: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

DEFINE NECESSARY MODIFICATIONS

MONITORS /SPEAKERS

SEATS

CABINETS HANGERS/LOCKERS

MEASURING INSTRUMENTS

PRIVACY PROTECTION, E.G. FROSTED GLASS

Page 8: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

OUR ENGENEERS WILL DESIGN THE FINAL PROJECT

MANUFACTURE & DELIVERY STAGE

Page 9: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

CASE STUDIES

Page 10: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

TELEMEDICINE BOOTH

SPECIFICATIONS:1 Dimmable led ceiling light 2 Air ventilation (presence sensor activated)3 Dials to adjust light intensity and fan speed4 Power module with USB 5 Compact desk6 Removable front panel for pallet jack 7 Flame retardand foam used in upholstery

MODIFICATIONS:

Frosted back and front glass for improving the privacy

Vinyl upholstery –

Vinyl carpet

1

W. 1600 mm/63 inH. 2300 mm/91 inD. 1200 mm/47 in

Desk:W. 960 mm/38 inD. 530 mm/20 in

Page 11: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

TELEMEDICINE BOOTH

SPECIFICATIONS:1 Dimmable led ceiling light 2 Air ventilation (presence sensor activated)3 Dials to adjust light intensity and fan speed4 Power module with USB 5 Compact desk6 Removable front panel for pallet jack 7 Flame retardand foam used in upholstery

MODIFICATIONS:

Frosted back and front glass for improving the privacy

Vinyl upholstery –

Vinyl carpet

1

W. 1600 mm/63 inH. 2300 mm/91 inD. 1200 mm/47 in

Desk:W. 960 mm/38 inD. 530 mm/20 in

Page 12: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

TELEMEDICINE BOOTH

SPECIFICATIONS:1 Dimmable led ceiling light 2 Air ventilation (presence sensor activated)3 Dials to adjust light intensity and fan speed4 Power module with USB 5 Compact desk6 Removable front panel for pallet jack 7 Flame retardand foam used in upholstery

MODIFICATIONS:

Frosted back and front glass for improving the privacy

Vinyl upholstery –

Vinyl carpet

1

W. 1600 mm/63 inH. 2300 mm/91 inD. 1200 mm/47 in

Desk:W. 960 mm/38 inD. 530 mm/20 in

Page 13: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

RELAX BOOTH

SPECIFICATIONS:1 Dimmable led ceiling light 2 Air ventilation (presence sensor activated)3 Dials to adjust light intensity and fan speed4 Power module with USB 5 Removable front panel for pallet jack 6 Flame retardand foam used in upholstery

MODIFICATIONS:

Dark back and front glass for improving the privacy

Frosted back and front glass for improving the privacy

Vinyl upholstery –

Vinyl carpet

Mirror mounted on the middle column

Shelves mounted on the back glass

Compact bed installed instead of standard meeting sofas

1

W. 2150 mm/85 inH. 2300 mm/91 inD. 1390 mm/56 in

Page 14: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

HEARING AID ADJUSTMENT BOOTH

SPECIFICATIONS:1 Dimmable led ceiling light 2 Air ventilation (presence sensor activated)3 Dials to adjust light intensity and fan speed4 Power module with USB 5 Removable front panel for pallet jack 6 Flame retardand foam used in upholstery

MODIFICATIONS:

Cabinets with table tops on the left and right side of the booth

The set of speakers helping to test the hearing aid

Additional USB&power module hubs under the tabletops

Logo embroidered in the middle module

TV screen placed on the wall

1

W. 2600 mmH. 2300 mmD. 2700 mm

Page 15: HUSH BOOTHS FOR MEDICAL APPLICA TIONS

YOURHUSHYOURHEALTH