    Huawei TX High temperature preventive maintenance SOP Security Level 0

    2012-03-26 Huawei Proprietary - Restricted Distribution Page1, Total6

    Huawei TX High temperature preventive maintenance SOP

    1. NOC SCOPE. (FM please check the chapter 2.)

    1.1How to monitor the alarm High temperature alarm.

    1.1.1 Please refer to this capture. Click on tab Fault> Browse curr ent alarm.

    1.1.2 Choose Copy fr om template> High Temp FO_Yovid

  • 7/30/2019 huawei tx high temperature preventive maintenance sop(noc scope and fm scope)

    2/6

    Huawei TX High temperature preventive maintenance SOP Security Level 0

    2012-03-26 Huawei Proprietary - Restricted Distribution Page2, Total6

    1.1.3 U2000 will display the template. Release ticket for each site which detected

    Temp_Alarm.Right click on the Memo Columnand site rowand choose Memo

    at the pop up window.

    1.1.4 And record the ticket number for Temp_Alarmcase

  • 7/30/2019 huawei tx high temperature preventive maintenance sop(noc scope and fm scope)

    3/6

    Huawei TX High temperature preventive maintenance SOP Security Level 0

    2012-03-26 Huawei Proprietary - Restricted Distribution Page3, Total6

    1.1.5 Check the alarm on site. For example site 090293_Inpres_Raya. Normally

    we can query the performance result site by site or at one subnet.

    1.1.6 Now we check one site, e.g site 090293. Righ t Cli ck at the NE, choose

    Browse SDH Perf ormance

  • 7/30/2019 huawei tx high temperature preventive maintenance sop(noc scope and fm scope)

    4/6

  • 7/30/2019 huawei tx high temperature preventive maintenance sop(noc scope and fm scope)

    5/6

    Huawei TX High temperature preventive maintenance SOP Security Level 0

    2012-03-26 Huawei Proprietary - Restricted Distribution Page5, Total6

    1.3.2 OSN/RTN in hub sites is Major_1, RTN in end sites is Major_2.

    1.3.3 Service affected base on service priority.

    1.4BO TX assigned one PIC to check the alarm and output weekly report for the TT

    processed quality (SLA). To show how many alarm have no TT, and how many

    alarm cleared successfully. For the long time processed TT, need escalation to FM

    RM/GM.

    2. FM SCOPE

    2.1FM must go to site within SLA.

    2.2Check the cabinet fan, clean it and if still not running well, replace it.

    2.3 Check the IDU Fan, clean the dust prevention and clean the fan. If still problem,

    replace it.

    Dust prevention

    Fan Card in RTN

  • 7/30/2019 huawei tx high temperature preventive maintenance sop(noc scope and fm scope)

    6/6

    Huawei TX High temperature preventive maintenance SOP Security Level 0

    2012-03-26 Huawei Proprietary - Restricted Distribution Page6, Total6

    2.3Base on the environment, if the alarm still occur, and FO reopen TT, Please

    escalate to FM RM/RTS to confirm for change the installation/add cabinet.

    Recommended bellow installation. Note: If no high temperature alarm occurs

    within 1 week, it means that installation no problem in that site.