huawei partner it product manual (storage section).pdf
TRANSCRIPT
-
Huawei Partner IT Product Manual Storage Section
HUAWEI TECHNOLOGIES CO., LTD.
-
1The channel storage products
Huawei storage products panorama
Big Data & Cloud Storage
Storage Software
SmartQoSSmartMotionSmartTier
SmartCacheSmartThinSmartX Insight
UltrPathUltraVRUltraAPM
Management ConsoleInfraControl
HyperSnap HyperClone
HyperCopy HyperReplication
Storage Management Software Data Replication Software
CSS Distributed Storage Big Data Storage N9000 UDS Massive Storage N8500 Clustered NAS
Active-Active cluster architectureFile and block interface 2~24 nodes, up to 15PB capacitySPECsfs2008 3M+ OPS Rich features for data management
Full symmetrix distributed architecture3~288 nodes, up to 40PB capacity SPECsfs2008 5M+ OPSDynamic storage tiering 10GE/Infiniband high-speed interconnect
Amazon S3 compliance EB level scalability High density design, 2PB+ in 1 rack
Disk Storage
S2200T
Dual controllers 4GB cache 204 disks
Up to 384GB cache Up to 1440 disks Up to 250K IOPS of SPC-1
2 ~ 16 controllers Up to 3TB cache Up to 3,216 disks 0~5s RPO Unified Storage, supports both block and file
applications Up to 192GB cache Up to 1,440 disks
S6800T HVS85T/HVS88TS2600T/S5500T/S5600T/S5800T
Open hardware and distributed file system architecturePosix/NFS/CIFS/JDBC/ODBC interfaceMulti-GE interconnect
Data Protection
HDP3500E VTL6900 Dorado5100 VIS6600TDorado2100 G2
Integrate with NBU DB, file and OS data protectionVM data protection
PB level scalability Cluster architecture Inline dedup and post- processing dedup
Disk Storage Up to 400K IOPS of
SPC-1Access latency low to 500sFour-level data protection
Up to 600K IOPS of SPC-1Access latency low to 500sFour-level data protection
2~8 nodes, Scale-outVirtual Storage
-
2SAN / Unied Storage Specications
The main SAN / Unied Storage
Huawei storage specications at a glance
Huawei storage specications at a glance
Model Architecture IOPSNumber of le engine
OPS CacheMaximum number of
drives
Disks per enclosure
drive type Host portBackend
port
backend port(per
controller)
S2200TSingle/Dual-controller
18,000 NA NA 2/4 204 12SAS/NL SAS/SATA
8 Gbps FC or 1 Gbps iSCSI
6Gb SAS 1
S2600T Dual-controller
40,266 * 2 100,000 8/16 276 12/24SSD/SAS/NL SAS/SATA
8Gbps FC, 1Gbps iSCSI, 10Gbps Iscsi(TOE)
6Gb SAS 2
S5500T Dual-controller
60,242 * 2/4 200,000 8/16/32 528 12/24SSD/SAS/NL SAS/SATA
8Gbps FC, 1Gbps iSCSI, 10Gbps iSCSI(TOE), 10Gbps FCoE
6Gb SAS 2
S5600T Dual-controller
102,471 * 2/4/6 300,000 24/48 1152 24 SSD/FC/SAS/NL SAS/SATA
4Gb FC/6Gb SAS
4/4~16
S5800T Dual-controller
130,000 2/4/6/8 400,000 96/192 1440 24 SSD/FC/SAS/NL SAS/SATA
4Gb FC/6Gb SAS
4/4~20
S6800T Dual-controller
250,388 * NA NA 192/384 1440 24 SSD/FC/SAS/NL SAS/SATA
4Gb FC/6Gb SAS
4/4~20
*: SPC-1 Result
HUAWEI EMC IBM NetApp HP Dell HDS
BAND7 300K~500k S6800T VMAXe XIV FAS6200 Compellent
BAND6 200K~300k S5800T VNX 7500 V7000U FAS3270 F400P6000
Compellent
AMS2500
BAND5 100K~200K S5600T VNX 5700 DS5300E7900FAS3240
F200P6000
PS6010
BAND4 50K~100K S5500T VNX 5500 DS5100E7900FAS3210
P6000 PS6000 AMS2300
BAND3 25K~50K S2600T VNX 5300 DS5020E5400FAS2240
P4000 PS4000 AMS2100
BAND2 5K~25K S2200TVNX 5100VNXe3300VNXe3100
DS3500E2600FAS2040
P2000MD3600MD3200
-
3All-solid-state storage & High-end NAS specications
The main high-end cluster NAS
Huawei storage specications at a glance
Huawei storage specications at a glance
Model ArchitectureSPC-1 IOPS
Number of host ports
Cache
Maximum number of drives orcapacity
Disks per enclosure
DriveHost port
Backend port
Maximum number of backend
port
Dorado2100 G2
Dual-controller
#8Gb FC : 1610 Gb iSCSI: 840Gb IB:4
48 100 25
SLC: 100GB/200GB; eMLC: 200GB/400GB
8Gbps FC/ 10GE (iSCSI) /40Gb IB
6Gb SAS 16
Dorado5100 Dual-controller
600,0528Gb FC : 4010GE : 20
96 96 24
SLC: 100GB/200GB; eMLC: 200GB/400GB
8Gbps FC/ 10GE (iSCSI)
6Gb SAS 20
N8500 2~24 nodes 3,064,602* 4~16/node16~192GB/node
15PB 12/24FC/SSD/SAS/NL_SAS/SATA
10GE/GE4Gb FC/6Gb SAS
NA
#: release later*: SPECsfs2008_nfs.v3 Result
PRICE(USD) HUAWEI EMCIsilon
IBMNetApp
FAS
BAND9 >1M
N8500
BAND8 500K~1M
BAND7 300K~500K N8500S200x400
N7900SoNAS
FAS6280FAS6080
BAND6 200K~300K N8500S200x400
N6060SoNAS
FAS6240FAS6040
-
4List of software function
Huawei storage specications at a glance
software Intended use S2200T S2600T/5500T/5600T/5800T
S6800T N8500 Dorado
Thin provisioning storage space is allocated based on the actual amount of written data , improve resource utilization
HyperThin HyperThin HyperThin HyperThin
SSD data cacheUsing SSD and hotspot identification technology, the hot data is copied from the HDD to the SSD to enhance the performance
SmartCache SmartCache SmartCache
SnapshotBased on the point-in-time data copy, provides data protection for local failure
HyperImageHyperImage(Block)Snapshot(File)
HyperImage HyperImage HyperImage
The heterogeneous volume data copy
Data migration between heterogeneous devices HyperCopy HyperCopy HyperCopy HyperCopy
Volume cloningprovide multiple real-time copies of data volumes, can be used for the production, testing
HyperClone HyerClone HyperClone
Synchronous remote replication
Provide data protection from power outages and disasters, to ensure zero data loss
HyperMirror (Synchronous)
HyperMirror(Synchronous)
HyperMirror (Synchronous)
HyperMirror (Synchronous)
HyperMirror (Synchronous)
Asynchronous remote replication
Provide a long distance data protection from power outages and disasters; can accept some data loss
HyperMirror (Asynchronous)
HyperMirror (Asynchronous) (Block)File Engine Replication(File)
HyperMirror (Asynchronous)
HyperMirror (Asynchronous) (Block)File Engine Replication(File)
HyperMirror (Asynchronous)
Host Disk Protection
Protect the host disk partition, the operating system and files
DiskGuard DiskGuard DiskGuard
data protection for application consistency
Require the data consistency of application program UltraAPM UltraAPM UltraAPM
Storage device management
Provide configuration, monitoring and management of storage device
ISM ISM ISM ISM ISM
NAS protocolsRequire standard protocol when hosts access NAS storage
CIFS/NFS/FTP/Http CIFS/NFS/FTP/Http
MultipathProvide path selection, path switching when hosts access SAN storage
UltraPath UltraPath UltraPath UltraPath
Storage Resource Management
Provide the end-to-end management of the storage from the host / virtual machine, network to storage device
InfraControl InfraControl InfraControl InfraControl
VMware VAAICompatible with vSphere VAAI to enhance the storage efficiency of virtual machine
Support 5.1 Support 5.1 Support 5.1 NA NA
Vmware SRM Compatible with Vmware SRM interface, realize disaster recovery of virtual machine
SRM 5.0; SRM 5.0 Update 1
SRM 5.0; SRM 5.0 Update 1
SMI-S CTPCompatible with SMI-S standard protocols, provides a standard interface for third-party management system
SMI-S 1.4 SMI-S 1.4
-
5Starter storage S2200T
Product description
Key selling points:
Entry-level price, 816TB Value
Low-end market leader with feature-rich software and
meet the full different demand.
Target Market
SMBs and remote /branch offices
Distributed DAS implementations
Large enterprise and corporate
distributed sites
Government and education
Current FC SAN Implementations
Customers with high-bandwidth
applications that require strong
sequential performance
Large file storage
Video capture/streaming
SharePoint & CAD
Backup-to-disk implementations
dual controllers single controller
S2200T Controller Enclosure
Product description
Controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS, NL SAS, and SATA disks Provides four 2+2 redundant coffer disks in the first four slots
Front view of the controller enclosure(single controller and dual controllers)
Rear view of the controller enclosure (dual controllers) Rear view of the controller enclosure (single controller)
Controller and disk integration (dual controller)
Provides management network ports and serial ports.Carries one onboard 4x6 Gbit/s SAS port. Supports one expansion I/O module. Carries four onboard GE ports.
Fan/BBUIntelligent fan speed controlBBUs are built in the system to provide power failure protection
Controller and disk integrationProvides management network ports and serial ports.Carries one onboard 4x6 Gbit/s SAS port.Carries four onboard GE ports.
Power module1+1 redundant Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)
-
6Unied Storage: T Series
Key selling points
Product description
Product description
Key selling points:
File & block fusion, network simplifies
Innovative Smart Series software, according
To the need of storage resources
Customer problems Product features Business Impact
Rapid data growth
Unified storage (files and data blocks)Scalable
Flexible
Structured and unstructured data coexist
Integration reduces the total cost of ownership
Large capacity to meet the rapid data growth
Meet stringent SLA
requirements
Redundant modules provide highly reliability
Hot swap technology
Designed to provide "five nines" availabilityA wealth of data protection features
To achieve the best level of service
High performance access
Always available (best state)
Data is protected
The complexity of the
storage tiering
Smartcache
Policy-based tiering
Automated tiering
Improve the performance of reading data
Easy to manage
Automation efficiency
Management costs
The unified support: files, data blocksStorage optimization technology, including
data blocks virtual file deduplication and virtual provisioning
Tiered storage (SSD, SAS, NL-SAS)
Value-added software
Cost-effective
Efficient storage utilizationReduce management costs
Cost-effective warranty options
FC/iSCSI
CIFS/NFS
SAN application server NAS application server
File engine components
Block engine components
Disks group components
-
7T Series components introduction: File Engine
T Series components introduction: S2600T Block Engine
Product description
Product description
The file engine of a T series unified storage system is developed on the Pangea V1R3 hardware platform. It is a 4 U independent engine and resembles the Pangea V1R1 hardware platform (S5500T/S5600T/S6800T controller enclosure).Each controller in the independent engine is a node of the file engine, that is, every engine provides two nodes.
Controller File engineOne controller is one node.
Interface moduleEach node has six I/O module slots. Each node has a GE card for heartbeat communication.Each node has an 8 Gbit/s Fiber Channel adapter for array connection.Each node has a maximum of four GE or 10GE adapters for NAS host interfaces.
File
Engine
S2600T/
S5500T
S5600T/
S5800T
CPU
One Intel
Xeon E5504
2.0 GHz
One Intel
Xeon E5645
2.4 GHz
Memory 16GB 24GB
3.5-inch controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS disks, SATA disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots
Power moduleAchieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)
Fan/BBUFan speed is intelligently controlled BBUs are built in the system to provide power failure protection
Controller module Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard GE ports
-
8T Series components introduction: S5600T/S5800T Block Engine
T Series components introduction: S5500T Block Engine
Product description
Product description
Controller module Provides management network ports and serial portsCarries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard 8 Gbit/s Fiber Channel ports
Fan/BBUFans are in 3+1 redundancy. (The system can tolerate the failure of one fan.)Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection
Fan5+1 redundancy (the failure of one fan is tolerable.)Intelligent fan speed control
BBU2+2 redundancy DC/AC power failure protection
Management module1+1 redundancy Hot-swappable
Power moduleDual power planes (2+2 redundancy) Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)
Controller moduleDual controllers Automatic CPU frequency control System power-off button
Interface module12 I/O module slots Up to 1440 hard disks Hot-swappable I/O modules Diversified interface types: 8 Gbit/s Fiber Channel, 4 Gbit/s Fiber Channel, 4x6 Gbit/s SAS, GE/10GE
2.5-inch controller enclosure:Houses twenty-four 2.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slotsIndependently powers on or off each hard disk
3.5-inch controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slotsIndependently powers on or off each hard disk
Power moduleAchieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)
-
9S6800T Block Engine
SAN S6800T
Product description
Product description
Fan module5+1 redundancy of fans (Faults on one fan do not affect the normal running of the system.)Intelligent fan speed adjustment
BBU module2+2 redundancy. Supports DC/AC power failure protection
Management module1+1 redundancy Supports hot swap
Power supply moduleDual plane power supply (2+2 redundancy) The transfer efficiency is up to 92% that is higher than that (88%) of gold medal power supply
Control moduleTwo controllers CPU frequency control, reducing power consumptionSystem power-off button
Interface moduleProvides 12 I/O modules slots Supports up to 1,440 hard disks Supports hot-swappable interface cards Supports various types of interfaces cards: 8 Gbit/s FC, 4 Gbit/s FC, 4 x 6 Gbit/s SAS, and GE/10GE
Key selling points:
Highly reliable architecture designed to ensure that
the customer's business system is secure
High-end quality, mid-range price
-
10
N8500
N8500 Hardware Infrastructure
Product description
Product description
OceanStor N8500 cluster NAS storage system is an industry-leading, unified storage platform for high-end applications, with
high performance, high scalability, high reliability, high efficient data management features.
N8500
Key selling points:
1st Leading performance: SPEC 3,064,602 OPS,
2 times to the 2nd
No single point failure, high reliability design
15PB exible space, hundred billion files
1Clustered NAS File Engine2Fabric Cable3FC Switch unit4Storage unit controller5Storage unit disk enclosure
Rack
GE switch unit (optional)
FC switch unit (optional)
Engine unit
Storage unit
The N8500 is based on the separation of the clustered NAS file engine and
the storage unit. The engine is either directly connected to the storage unit or
cascaded by using the FC switch
Suggested storage unit model: S5500T, S5600T, S5800T, S6800T
-
11
Direct connection (two nodes)
Switch connection (six nodes)
Product description
Product description
Two heartbeat switches
Two heartbeat links
FC switches
N8500 Engine
Storage unit
Storage unit
Two heartbeat links
FC port
GE port
Heartbeat port
FC port
GE port
Heartbeat port
-
12
N8500 NAS File Engine
Product description
Fan moduleFan 5+1 redundancy Low power consumption for heat dissipationGranular fan speed control
Local system moduleEmbedded reliable SSD as the local system diskEach system module provides an independent management port.Each system module provides a serial port for software debugging
Power module2+2 redundancy 92% power conversion efficiency
Control moduleTwo controllers Mainstream server platform Automatic frequency adjustment, reducing power consumptionSystem power-off button
Interface moduleBy default, each node provides four GE service interfaces, four 8 Gbit/s FC back-end storage interfaces, and two GE heartbeat interfacesEach node provides three PCE2.0 8x interface card slots for the expansion of GE/10GE service interface card or 8 Gbit/s FC back-end storage interface cardAll the interface cards support hot swapping
BBU module apron2+2 redundancy DC/AC power failure protection
Storage Unit Controller with Disks: S5500T Block Engine
Product description
Control module integrating controller and diskMainstream desktop CPU platform Provides management network ports and serial ports. Two integrated 6 Gbit/s SAS interfaces. Supports 1 interface module Four integrated 8 Gbit/s FC interfaces
Fan module/BBU moduleFan 3+1 redundancy Delicate fan speed control Embedded BBU to protect data when a power-off occurs
2.5-inch disk enclosure24 x 2.5-inch hard disks Support mainstream disks, such as SAS, SATA, and SSDThe first four disks are coffer disks, forming 2+2 redundancyEach disk can be independently powered on/off
3.5-inch disk enclosure12 x 3.5-inch disks Support mainstream disks, such as SAS, SATA, and SSDThe first four disks are coffer disks, forming 2+2 redundancyEach disk can be independently powered on/off
Power module1+1 redundancy 92% power conversion efficiency
-
13
Storage Unit Controller without Disks: S5600T/S5800T/S6800T Block Engine
Product description
Fan moduleFan 5+1 redundancy Low power consumption for heat dissipation. Granular fan speed control
BBU module2+2 redundancy DC/AC power failure protection
Management module2+2 redundancy Hot swap Embedded reliable SSD as the system coffer
Control moduleTwo controllers Mainstream server platform Automatic frequency adjustment, reducing power consumptionSystem power-off button
Interface module12 interface card slots A maximum of 1440 hard disks All the interface cards support hot swapping Various interface types, such as 8 Gbit/s FC, 4 Gbit/s FC, 6 Gbit/s SAS, GE, and 10GE
Power module2+2 redundancy 92% power conversion efficiency
All-solid state storage Dorado
Product description
Huawei OceanStor Dorado series are high-performance all-solid-state SAN for enterprises, with the advanced cache
management and I / O scheduling algorithm, based on the design of all-solid-state storage system architecture, provide
users performance experience, to meet the needs of large database, high-performance computing, VDI and other different
applications of high-performance storage.
Dorado2100 G2 Dorado5100
-
14
Dorado2100 G2
Dorado 5100
Product description
Product description
Key selling points:
600K IOPS, Microsecond-level access latency,
providing ultra high efficiency.
Fully redundant architecture, Active/Active mode,
enabling services to always remain online.
Key selling points:
1M IOPS, Microsecond-level access latency,
providing ultra high efficiency.
Fully redundant architecture, Active/Active mode,
enabling services to always remain online.
Superior performance
Dorado2100 G2 provides up to 600K IOPS, equivalent in performance to the traditional array with 750 pcs 15K rpm SAS hard drives.
Access time: access latency is as low as 500 s, only 5% of the traditional array delay.
Green energy-saving
Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same
performance, energy saves up to 90%.
Stable and reliable
Proprietary four level data protection architecture eliminate single point failure, keep business continuing
Superior performance
SPC-1 IOPS: Dorado5100 provides up to 600,052 SPC-1 IOPS , equivalent in performance to the traditional array with 2000 15K rpm SAS
hard drives.
Access time: access latency is as low as 500 s, only 5% of the traditional array delay.
Green energy-saving
Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same
performance, energy saves up to 90%.
Stable and reliable
Proprietary four level data protection architecture eliminate single point failure, keep business continuing
-
Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information
is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.
Trademark Notice
, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are the property of their respective owners.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-035262-20130316-C-4.0
www.huawei.com