huawei partner it product manual (storage section).pdf

16
Huawei Partner IT Product Manual Storage Section HUAWEI TECHNOLOGIES CO., LTD.

Upload: menganofulano

Post on 25-Nov-2015

201 views

Category:

Documents


2 download

TRANSCRIPT

  • Huawei Partner IT Product Manual Storage Section

    HUAWEI TECHNOLOGIES CO., LTD.

  • 1The channel storage products

    Huawei storage products panorama

    Big Data & Cloud Storage

    Storage Software

    SmartQoSSmartMotionSmartTier

    SmartCacheSmartThinSmartX Insight

    UltrPathUltraVRUltraAPM

    Management ConsoleInfraControl

    HyperSnap HyperClone

    HyperCopy HyperReplication

    Storage Management Software Data Replication Software

    CSS Distributed Storage Big Data Storage N9000 UDS Massive Storage N8500 Clustered NAS

    Active-Active cluster architectureFile and block interface 2~24 nodes, up to 15PB capacitySPECsfs2008 3M+ OPS Rich features for data management

    Full symmetrix distributed architecture3~288 nodes, up to 40PB capacity SPECsfs2008 5M+ OPSDynamic storage tiering 10GE/Infiniband high-speed interconnect

    Amazon S3 compliance EB level scalability High density design, 2PB+ in 1 rack

    Disk Storage

    S2200T

    Dual controllers 4GB cache 204 disks

    Up to 384GB cache Up to 1440 disks Up to 250K IOPS of SPC-1

    2 ~ 16 controllers Up to 3TB cache Up to 3,216 disks 0~5s RPO Unified Storage, supports both block and file

    applications Up to 192GB cache Up to 1,440 disks

    S6800T HVS85T/HVS88TS2600T/S5500T/S5600T/S5800T

    Open hardware and distributed file system architecturePosix/NFS/CIFS/JDBC/ODBC interfaceMulti-GE interconnect

    Data Protection

    HDP3500E VTL6900 Dorado5100 VIS6600TDorado2100 G2

    Integrate with NBU DB, file and OS data protectionVM data protection

    PB level scalability Cluster architecture Inline dedup and post- processing dedup

    Disk Storage Up to 400K IOPS of

    SPC-1Access latency low to 500sFour-level data protection

    Up to 600K IOPS of SPC-1Access latency low to 500sFour-level data protection

    2~8 nodes, Scale-outVirtual Storage

  • 2SAN / Unied Storage Specications

    The main SAN / Unied Storage

    Huawei storage specications at a glance

    Huawei storage specications at a glance

    Model Architecture IOPSNumber of le engine

    OPS CacheMaximum number of

    drives

    Disks per enclosure

    drive type Host portBackend

    port

    backend port(per

    controller)

    S2200TSingle/Dual-controller

    18,000 NA NA 2/4 204 12SAS/NL SAS/SATA

    8 Gbps FC or 1 Gbps iSCSI

    6Gb SAS 1

    S2600T Dual-controller

    40,266 * 2 100,000 8/16 276 12/24SSD/SAS/NL SAS/SATA

    8Gbps FC, 1Gbps iSCSI, 10Gbps Iscsi(TOE)

    6Gb SAS 2

    S5500T Dual-controller

    60,242 * 2/4 200,000 8/16/32 528 12/24SSD/SAS/NL SAS/SATA

    8Gbps FC, 1Gbps iSCSI, 10Gbps iSCSI(TOE), 10Gbps FCoE

    6Gb SAS 2

    S5600T Dual-controller

    102,471 * 2/4/6 300,000 24/48 1152 24 SSD/FC/SAS/NL SAS/SATA

    4Gb FC/6Gb SAS

    4/4~16

    S5800T Dual-controller

    130,000 2/4/6/8 400,000 96/192 1440 24 SSD/FC/SAS/NL SAS/SATA

    4Gb FC/6Gb SAS

    4/4~20

    S6800T Dual-controller

    250,388 * NA NA 192/384 1440 24 SSD/FC/SAS/NL SAS/SATA

    4Gb FC/6Gb SAS

    4/4~20

    *: SPC-1 Result

    HUAWEI EMC IBM NetApp HP Dell HDS

    BAND7 300K~500k S6800T VMAXe XIV FAS6200 Compellent

    BAND6 200K~300k S5800T VNX 7500 V7000U FAS3270 F400P6000

    Compellent

    AMS2500

    BAND5 100K~200K S5600T VNX 5700 DS5300E7900FAS3240

    F200P6000

    PS6010

    BAND4 50K~100K S5500T VNX 5500 DS5100E7900FAS3210

    P6000 PS6000 AMS2300

    BAND3 25K~50K S2600T VNX 5300 DS5020E5400FAS2240

    P4000 PS4000 AMS2100

    BAND2 5K~25K S2200TVNX 5100VNXe3300VNXe3100

    DS3500E2600FAS2040

    P2000MD3600MD3200

  • 3All-solid-state storage & High-end NAS specications

    The main high-end cluster NAS

    Huawei storage specications at a glance

    Huawei storage specications at a glance

    Model ArchitectureSPC-1 IOPS

    Number of host ports

    Cache

    Maximum number of drives orcapacity

    Disks per enclosure

    DriveHost port

    Backend port

    Maximum number of backend

    port

    Dorado2100 G2

    Dual-controller

    #8Gb FC : 1610 Gb iSCSI: 840Gb IB:4

    48 100 25

    SLC: 100GB/200GB; eMLC: 200GB/400GB

    8Gbps FC/ 10GE (iSCSI) /40Gb IB

    6Gb SAS 16

    Dorado5100 Dual-controller

    600,0528Gb FC : 4010GE : 20

    96 96 24

    SLC: 100GB/200GB; eMLC: 200GB/400GB

    8Gbps FC/ 10GE (iSCSI)

    6Gb SAS 20

    N8500 2~24 nodes 3,064,602* 4~16/node16~192GB/node

    15PB 12/24FC/SSD/SAS/NL_SAS/SATA

    10GE/GE4Gb FC/6Gb SAS

    NA

    #: release later*: SPECsfs2008_nfs.v3 Result

    PRICE(USD) HUAWEI EMCIsilon

    IBMNetApp

    FAS

    BAND9 >1M

    N8500

    BAND8 500K~1M

    BAND7 300K~500K N8500S200x400

    N7900SoNAS

    FAS6280FAS6080

    BAND6 200K~300K N8500S200x400

    N6060SoNAS

    FAS6240FAS6040

  • 4List of software function

    Huawei storage specications at a glance

    software Intended use S2200T S2600T/5500T/5600T/5800T

    S6800T N8500 Dorado

    Thin provisioning storage space is allocated based on the actual amount of written data , improve resource utilization

    HyperThin HyperThin HyperThin HyperThin

    SSD data cacheUsing SSD and hotspot identification technology, the hot data is copied from the HDD to the SSD to enhance the performance

    SmartCache SmartCache SmartCache

    SnapshotBased on the point-in-time data copy, provides data protection for local failure

    HyperImageHyperImage(Block)Snapshot(File)

    HyperImage HyperImage HyperImage

    The heterogeneous volume data copy

    Data migration between heterogeneous devices HyperCopy HyperCopy HyperCopy HyperCopy

    Volume cloningprovide multiple real-time copies of data volumes, can be used for the production, testing

    HyperClone HyerClone HyperClone

    Synchronous remote replication

    Provide data protection from power outages and disasters, to ensure zero data loss

    HyperMirror (Synchronous)

    HyperMirror(Synchronous)

    HyperMirror (Synchronous)

    HyperMirror (Synchronous)

    HyperMirror (Synchronous)

    Asynchronous remote replication

    Provide a long distance data protection from power outages and disasters; can accept some data loss

    HyperMirror (Asynchronous)

    HyperMirror (Asynchronous) (Block)File Engine Replication(File)

    HyperMirror (Asynchronous)

    HyperMirror (Asynchronous) (Block)File Engine Replication(File)

    HyperMirror (Asynchronous)

    Host Disk Protection

    Protect the host disk partition, the operating system and files

    DiskGuard DiskGuard DiskGuard

    data protection for application consistency

    Require the data consistency of application program UltraAPM UltraAPM UltraAPM

    Storage device management

    Provide configuration, monitoring and management of storage device

    ISM ISM ISM ISM ISM

    NAS protocolsRequire standard protocol when hosts access NAS storage

    CIFS/NFS/FTP/Http CIFS/NFS/FTP/Http

    MultipathProvide path selection, path switching when hosts access SAN storage

    UltraPath UltraPath UltraPath UltraPath

    Storage Resource Management

    Provide the end-to-end management of the storage from the host / virtual machine, network to storage device

    InfraControl InfraControl InfraControl InfraControl

    VMware VAAICompatible with vSphere VAAI to enhance the storage efficiency of virtual machine

    Support 5.1 Support 5.1 Support 5.1 NA NA

    Vmware SRM Compatible with Vmware SRM interface, realize disaster recovery of virtual machine

    SRM 5.0; SRM 5.0 Update 1

    SRM 5.0; SRM 5.0 Update 1

    SMI-S CTPCompatible with SMI-S standard protocols, provides a standard interface for third-party management system

    SMI-S 1.4 SMI-S 1.4

  • 5Starter storage S2200T

    Product description

    Key selling points:

    Entry-level price, 816TB Value

    Low-end market leader with feature-rich software and

    meet the full different demand.

    Target Market

    SMBs and remote /branch offices

    Distributed DAS implementations

    Large enterprise and corporate

    distributed sites

    Government and education

    Current FC SAN Implementations

    Customers with high-bandwidth

    applications that require strong

    sequential performance

    Large file storage

    Video capture/streaming

    SharePoint & CAD

    Backup-to-disk implementations

    dual controllers single controller

    S2200T Controller Enclosure

    Product description

    Controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS, NL SAS, and SATA disks Provides four 2+2 redundant coffer disks in the first four slots

    Front view of the controller enclosure(single controller and dual controllers)

    Rear view of the controller enclosure (dual controllers) Rear view of the controller enclosure (single controller)

    Controller and disk integration (dual controller)

    Provides management network ports and serial ports.Carries one onboard 4x6 Gbit/s SAS port. Supports one expansion I/O module. Carries four onboard GE ports.

    Fan/BBUIntelligent fan speed controlBBUs are built in the system to provide power failure protection

    Controller and disk integrationProvides management network ports and serial ports.Carries one onboard 4x6 Gbit/s SAS port.Carries four onboard GE ports.

    Power module1+1 redundant Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

  • 6Unied Storage: T Series

    Key selling points

    Product description

    Product description

    Key selling points:

    File & block fusion, network simplifies

    Innovative Smart Series software, according

    To the need of storage resources

    Customer problems Product features Business Impact

    Rapid data growth

    Unified storage (files and data blocks)Scalable

    Flexible

    Structured and unstructured data coexist

    Integration reduces the total cost of ownership

    Large capacity to meet the rapid data growth

    Meet stringent SLA

    requirements

    Redundant modules provide highly reliability

    Hot swap technology

    Designed to provide "five nines" availabilityA wealth of data protection features

    To achieve the best level of service

    High performance access

    Always available (best state)

    Data is protected

    The complexity of the

    storage tiering

    Smartcache

    Policy-based tiering

    Automated tiering

    Improve the performance of reading data

    Easy to manage

    Automation efficiency

    Management costs

    The unified support: files, data blocksStorage optimization technology, including

    data blocks virtual file deduplication and virtual provisioning

    Tiered storage (SSD, SAS, NL-SAS)

    Value-added software

    Cost-effective

    Efficient storage utilizationReduce management costs

    Cost-effective warranty options

    FC/iSCSI

    CIFS/NFS

    SAN application server NAS application server

    File engine components

    Block engine components

    Disks group components

  • 7T Series components introduction: File Engine

    T Series components introduction: S2600T Block Engine

    Product description

    Product description

    The file engine of a T series unified storage system is developed on the Pangea V1R3 hardware platform. It is a 4 U independent engine and resembles the Pangea V1R1 hardware platform (S5500T/S5600T/S6800T controller enclosure).Each controller in the independent engine is a node of the file engine, that is, every engine provides two nodes.

    Controller File engineOne controller is one node.

    Interface moduleEach node has six I/O module slots. Each node has a GE card for heartbeat communication.Each node has an 8 Gbit/s Fiber Channel adapter for array connection.Each node has a maximum of four GE or 10GE adapters for NAS host interfaces.

    File

    Engine

    S2600T/

    S5500T

    S5600T/

    S5800T

    CPU

    One Intel

    Xeon E5504

    2.0 GHz

    One Intel

    Xeon E5645

    2.4 GHz

    Memory 16GB 24GB

    3.5-inch controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS disks, SATA disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots

    Power moduleAchieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

    Fan/BBUFan speed is intelligently controlled BBUs are built in the system to provide power failure protection

    Controller module Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard GE ports

  • 8T Series components introduction: S5600T/S5800T Block Engine

    T Series components introduction: S5500T Block Engine

    Product description

    Product description

    Controller module Provides management network ports and serial portsCarries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard 8 Gbit/s Fiber Channel ports

    Fan/BBUFans are in 3+1 redundancy. (The system can tolerate the failure of one fan.)Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection

    Fan5+1 redundancy (the failure of one fan is tolerable.)Intelligent fan speed control

    BBU2+2 redundancy DC/AC power failure protection

    Management module1+1 redundancy Hot-swappable

    Power moduleDual power planes (2+2 redundancy) Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

    Controller moduleDual controllers Automatic CPU frequency control System power-off button

    Interface module12 I/O module slots Up to 1440 hard disks Hot-swappable I/O modules Diversified interface types: 8 Gbit/s Fiber Channel, 4 Gbit/s Fiber Channel, 4x6 Gbit/s SAS, GE/10GE

    2.5-inch controller enclosure:Houses twenty-four 2.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slotsIndependently powers on or off each hard disk

    3.5-inch controller enclosureHouses 12x3.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slotsIndependently powers on or off each hard disk

    Power moduleAchieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

  • 9S6800T Block Engine

    SAN S6800T

    Product description

    Product description

    Fan module5+1 redundancy of fans (Faults on one fan do not affect the normal running of the system.)Intelligent fan speed adjustment

    BBU module2+2 redundancy. Supports DC/AC power failure protection

    Management module1+1 redundancy Supports hot swap

    Power supply moduleDual plane power supply (2+2 redundancy) The transfer efficiency is up to 92% that is higher than that (88%) of gold medal power supply

    Control moduleTwo controllers CPU frequency control, reducing power consumptionSystem power-off button

    Interface moduleProvides 12 I/O modules slots Supports up to 1,440 hard disks Supports hot-swappable interface cards Supports various types of interfaces cards: 8 Gbit/s FC, 4 Gbit/s FC, 4 x 6 Gbit/s SAS, and GE/10GE

    Key selling points:

    Highly reliable architecture designed to ensure that

    the customer's business system is secure

    High-end quality, mid-range price

  • 10

    N8500

    N8500 Hardware Infrastructure

    Product description

    Product description

    OceanStor N8500 cluster NAS storage system is an industry-leading, unified storage platform for high-end applications, with

    high performance, high scalability, high reliability, high efficient data management features.

    N8500

    Key selling points:

    1st Leading performance: SPEC 3,064,602 OPS,

    2 times to the 2nd

    No single point failure, high reliability design

    15PB exible space, hundred billion files

    1Clustered NAS File Engine2Fabric Cable3FC Switch unit4Storage unit controller5Storage unit disk enclosure

    Rack

    GE switch unit (optional)

    FC switch unit (optional)

    Engine unit

    Storage unit

    The N8500 is based on the separation of the clustered NAS file engine and

    the storage unit. The engine is either directly connected to the storage unit or

    cascaded by using the FC switch

    Suggested storage unit model: S5500T, S5600T, S5800T, S6800T

  • 11

    Direct connection (two nodes)

    Switch connection (six nodes)

    Product description

    Product description

    Two heartbeat switches

    Two heartbeat links

    FC switches

    N8500 Engine

    Storage unit

    Storage unit

    Two heartbeat links

    FC port

    GE port

    Heartbeat port

    FC port

    GE port

    Heartbeat port

  • 12

    N8500 NAS File Engine

    Product description

    Fan moduleFan 5+1 redundancy Low power consumption for heat dissipationGranular fan speed control

    Local system moduleEmbedded reliable SSD as the local system diskEach system module provides an independent management port.Each system module provides a serial port for software debugging

    Power module2+2 redundancy 92% power conversion efficiency

    Control moduleTwo controllers Mainstream server platform Automatic frequency adjustment, reducing power consumptionSystem power-off button

    Interface moduleBy default, each node provides four GE service interfaces, four 8 Gbit/s FC back-end storage interfaces, and two GE heartbeat interfacesEach node provides three PCE2.0 8x interface card slots for the expansion of GE/10GE service interface card or 8 Gbit/s FC back-end storage interface cardAll the interface cards support hot swapping

    BBU module apron2+2 redundancy DC/AC power failure protection

    Storage Unit Controller with Disks: S5500T Block Engine

    Product description

    Control module integrating controller and diskMainstream desktop CPU platform Provides management network ports and serial ports. Two integrated 6 Gbit/s SAS interfaces. Supports 1 interface module Four integrated 8 Gbit/s FC interfaces

    Fan module/BBU moduleFan 3+1 redundancy Delicate fan speed control Embedded BBU to protect data when a power-off occurs

    2.5-inch disk enclosure24 x 2.5-inch hard disks Support mainstream disks, such as SAS, SATA, and SSDThe first four disks are coffer disks, forming 2+2 redundancyEach disk can be independently powered on/off

    3.5-inch disk enclosure12 x 3.5-inch disks Support mainstream disks, such as SAS, SATA, and SSDThe first four disks are coffer disks, forming 2+2 redundancyEach disk can be independently powered on/off

    Power module1+1 redundancy 92% power conversion efficiency

  • 13

    Storage Unit Controller without Disks: S5600T/S5800T/S6800T Block Engine

    Product description

    Fan moduleFan 5+1 redundancy Low power consumption for heat dissipation. Granular fan speed control

    BBU module2+2 redundancy DC/AC power failure protection

    Management module2+2 redundancy Hot swap Embedded reliable SSD as the system coffer

    Control moduleTwo controllers Mainstream server platform Automatic frequency adjustment, reducing power consumptionSystem power-off button

    Interface module12 interface card slots A maximum of 1440 hard disks All the interface cards support hot swapping Various interface types, such as 8 Gbit/s FC, 4 Gbit/s FC, 6 Gbit/s SAS, GE, and 10GE

    Power module2+2 redundancy 92% power conversion efficiency

    All-solid state storage Dorado

    Product description

    Huawei OceanStor Dorado series are high-performance all-solid-state SAN for enterprises, with the advanced cache

    management and I / O scheduling algorithm, based on the design of all-solid-state storage system architecture, provide

    users performance experience, to meet the needs of large database, high-performance computing, VDI and other different

    applications of high-performance storage.

    Dorado2100 G2 Dorado5100

  • 14

    Dorado2100 G2

    Dorado 5100

    Product description

    Product description

    Key selling points:

    600K IOPS, Microsecond-level access latency,

    providing ultra high efficiency.

    Fully redundant architecture, Active/Active mode,

    enabling services to always remain online.

    Key selling points:

    1M IOPS, Microsecond-level access latency,

    providing ultra high efficiency.

    Fully redundant architecture, Active/Active mode,

    enabling services to always remain online.

    Superior performance

    Dorado2100 G2 provides up to 600K IOPS, equivalent in performance to the traditional array with 750 pcs 15K rpm SAS hard drives.

    Access time: access latency is as low as 500 s, only 5% of the traditional array delay.

    Green energy-saving

    Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same

    performance, energy saves up to 90%.

    Stable and reliable

    Proprietary four level data protection architecture eliminate single point failure, keep business continuing

    Superior performance

    SPC-1 IOPS: Dorado5100 provides up to 600,052 SPC-1 IOPS , equivalent in performance to the traditional array with 2000 15K rpm SAS

    hard drives.

    Access time: access latency is as low as 500 s, only 5% of the traditional array delay.

    Green energy-saving

    Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same

    performance, energy saves up to 90%.

    Stable and reliable

    Proprietary four level data protection architecture eliminate single point failure, keep business continuing

  • Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.

    No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

    General Disclaimer

    The information in this document may contain predictive statements including,

    without limitation, statements regarding the future financial and operating results,

    future product portfolio, new technology, etc. There are a number of factors

    that could cause actual results and developments to differ materially from those

    expressed or implied in the predictive statements. Therefore, such information

    is provided for reference purpose only and constitutes neither an offer nor an

    acceptance. Huawei may change the information at any time without notice.

    Trademark Notice

    , HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.

    Other trademarks, product, service and company names mentioned are the property of their respective owners.

    HUAWEI TECHNOLOGIES CO., LTD.

    Huawei Industrial Base

    Bantian Longgang

    Shenzhen 518129, P.R. China

    Tel: +86-755-28780808

    Version No.: M3-035262-20130316-C-4.0

    www.huawei.com