huawei fusionserver x6800 quotation guide - actfornet x6800 … · •huawei confidential 1...

19
www.huawei.com HUAWEI TECHNOLOGIES CO., LTD. Huawei FusionServer X6800 Quotation Guide

Upload: trinhkien

Post on 13-May-2018

247 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

Huawei FusionServer X6800 Quotation Guide

Page 2: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

1www.huawei.com • Huawei Confidential

Content

Configuration Parameter Introduction1

Quotation Entrance2

3 Example

Page 3: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

2www.huawei.com • Huawei Confidential

XH620 V3 2-Socket Compute NodeX

H6

20

V3

ap

pe

ara

nce

Exterior of the XH620V3

Node

Form factor Single-slot 2-socket server node

Number of CPUs One or two

CPU model Intel Xeon E5-2600 v3

DIMM slot 16 DDR4 DIMM slots, supporting a maximum memory capacity of 1024 GB

Number of hard disksFour or two 2.5-inch SAS/SATA HDDs or SSDs or two 3.5-inch SAS/SATA

HDDs

LOM network port(Optional) two GE network ports, four GE network ports, two 10GE optical ports, or two 10GE electrical ports

RAID support RAID 0, 1, 10, 5, 6, supporting a supercapacitor

PCIe expansion capacityUp to three PCIe expansion slots: one front half-height half-length PCIe 3.0 x8 slots, one rear half-height half-length PCIe 3.0 x8 slots, and one RAID controller card.

Onboard storage medium Two Mini SSDs(SATA DOMs) and one USB flash drive

Front portOne high-density port (one VGA port, three USB 2.0 port, and one serial port), and one GE management network port

Operating temperature 5℃ to 40℃

Dimensions (H x W x D)

XH620 V3 is a single-slot node. A X6800 can house eight XH620 V3 nodes, that is, 4 U/8 nodes. Note that XH620 V3 supports three types of

configuration.:

2 x 2.5-inch SAS HDDs, SATA HDDs, or SSDs at the front + 1 x Standard HHHL PCIe card (front)

4 x 2.5-inch SAS HDDs, SATA HDDs, or SSDs at the front

Built-in 2 x 3.5-inch non-hot-swappable SATA HDDs

Note: Besides the preceding configuration, the X6800 chassis has eight half-height half-length PCIe expansion slots at the rear, each

corresponding to one XH620 V3 node.

Page 4: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

3www.huawei.com • Huawei Confidential

Form factor Dual-slot 2-socket server node

Number of CPUs One or two

CPU model Intel Xeon E5-2600 v3

DIMM slot 16 DDR4 DIMM slots, supporting a maximum memory capacity of 1024 GB

Number of hard disks12*3.5" or 2.5" hot-swappable SAS/SATA disks or SSDs, with two 2.5" SATA disks/SSDs for option

LOM network port(Optional) two GE network ports, four GE network ports, two 10GE optical ports, or two 10GE electrical ports

RAID support RAID 0, 1, 10, 5, 50, 6, and 60, supporting a supercapacitor

PCIe expansion capacity

Up to five PCIe expansion slots: two front half-height half-length PCIe 3.0 x8 slots, two rear half-height half-length PCIe 3.0 x8 slots, and one RAID controller card. The front PCIe slots and the two 2.5-inch disks cannot be configured at the same time.

Onboard storage medium

Two Mini SSDs(SATA DOMs) and one USB flash drive

Front portOne high-density port (one VGA port, three USB 2.0 port, and one serial port), and one GE management network port

Operating temperature 5℃ to 40℃

Dimensions (H x W x D) 109 mm x 745 mm x 166 mm

XH

628

V3

ap

pe

ara

nce

Exterior of the XH628 V3

Node

XH628 V3 2-Socket Storage Node

XH628 V3 is a dual-slot node. A X6800 chassis can house four XH628 V3 nodes, that is, 4 U/8 nodes.

Each node can be configured with 12 x 3.5- or 2.5-inch hard disks. The two expansion nodes on the front support 2 x 2.5-inch hard disks or PCIe

cards.

Each XH628 V3 node has five PCIe expansion slots: two at the front, two at the rear I/O module, and one on-board RAID controller card.

Page 5: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

4www.huawei.com • Huawei Confidential

Form factor Dual-slot 2-socket server node

Number of CPUs One or two

CPU model Intel Xeon E5-2600 v3

DIMM slot 16 DDR4 DIMM slots, supporting a maximum memory capacity of 1024 GB

Number of hard disks Four 2.5-inch SAS/SATA disks or SSDs

LOM network port(Optional) two GE network ports, four GE network ports, two 10GE optical ports, or two 10GE electrical ports

RAID support RAID 0, 1, 10, 5, 6, supporting a supercapacitor

PCIe expansion capacityUp to five PCIe expansion slots: two built-in double-width, full-height, full-length PCIe 3.0 x16 slots, two rear half-height half-length PCIe 3.0 x8 slots, and one RAID controller card

Onboard storage medium Two Mini SSDs(SATA DOMs) and one USB flash drive

Front portOne high-density port (one VGA port, three USB 2.0 port, and one serial port), and one GE management network port

Operating temperature 5℃ to 40℃

Dimensions (H x W x D) 109 mm x 670 mm x 166 mm

XH

622

V3

ap

pe

ara

nce

Exterior of the XH622 V3

Node

XH622 V3 2-Socket GPU Node

Page 6: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

5www.huawei.com • Huawei Confidential

Configuration parameter

1. Please confirm the specifications of the cabinet can match X6800:X6800 chassis depth of 898mm, 1.2m or more

cabinet depth requirements, the cabinet from the front door suggestion square hole distance 140mm, details

refer to "Huawei X6800 Datacenter Server White Paper"

2. Please select the type of Server Node:

XH620 V3 Node(Support front 4*2.5" HDD from PCH) : Not supporting SAS

XH620 V3 Node(Support front 4*2.5" HDD from RAID card)

XH620 V3 Node(Support front 2*2.5" HDD from PCH,Front low profile 1X8 PCIe slot) : Not supporting SAS

XH620 V3 Node(Support front 2*2.5" HDD from RAID card,Front low profile 1X8 PCIe slot)

XH620 V3 Node(Support Bulit-in 2*3.5" HDD from PCH) : Not supporting SAS

XH628 V3 Node(Support front 2*2.5" HDD, Built 12*3.5" HDD)

XH628 V3 Node(Support front 2*low profile X8 PCIe slots, Built 12*3.5 " HDD)

XH622 V3 Node(Support front 4*2.5" HDD from PCH, Built 2*GPU) : Not supporting SAS

XH622 V3 Node(Support front 4*2.5" HDD from RAID card, Built 2*GPU)

4. Please select the quantity of Server Node in Single Chassis : select the numbers of the nodes.

Page 7: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

6www.huawei.com • Huawei Confidential

Configuration parameterNode Base Configuration

1.CPU:Select the CPU model and quantity for each node.

2.Memory:Select the memory model and quantity for each node.

3.Hard disk:The 2.5- or 3.5-inch disk options are displayed based on the selected node, and you only need to select

a desired model. For example, for a XH620 V3 node with 4 x 2.5-inch disks, no 2.5-inch disk option is displayed

because the node cannot house any 2.5-inch disks. For a XH620 V3 node with 2 x 3.5-inch disk, a 3.5-inch disk

option is displayed.

4.RAID Card:Select the model of the RAID controller card. The second option is whether to support SoftRAID. If

hard disks are connected to the south bridge, and RAID arrays are required, you can install the RAID software

on the OS to implement RAID arrays. However, only specified OSs are supported (see the compatibility list). This

SoftRAID configuration consumes system resources and supports only SATA disks.

5.Network Interface Card:Select a desired network interface card.

6.PCIe Card:Select a desired PCIe card. To configure a PCIe card at the rear of the X6800 chassis, select "Support

Rear I/O Board" and "Rear I/O Interface Board."

7.Back IO Switch Board:Only an I/O interface board can be configured with a rear PCIe card.

8.Insert Card:Options include USB flash drive, SATA DOM(Mini SSD), and security encryption. Each X6800 node

supports one USB flash drive and two SATA DOMs. For example, if you want to install OSs on SATA DOMs or

use all hard disks to store data, you can use SATA DOMs.

19.Operating Systm:Select a desired OS.

Page 8: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

7www.huawei.com • Huawei Confidential

Configuration parameterValue added service:

1.Need the Function Custom-made

2.Need the Appearance Custom-made

3.Need the Software pre-installment

4.Need the White Card Custom-made

Chassis basic configuration:

1.There are two choices for the Chassis: “support back IO board” and “not support back IO board”. If you

choose “support back IO board”, there appears other two options, “ PCIe Card” and “Need the back IO

switch or not” as X6800 has IO module in the back of the chassis( 8 PCIe expansion slots). If you choose

“support back IO board”, you will have this module, then there will be options of “PCIe card” and “Need

the bac IO switch or not” in the node configuration.

2.Please select the type of Power Supply: select the power supply needed

The link of the power calculator:

http://3ms.huawei.com/mm/docMaintain/mmMaintain.do?method=showMMDetail&f_id=SV14010630220023

3.Please select the type of C13 AC power cord:

4.Need the external DVDRW or not:

5.Please select the Rack Rail:

6.IT Equipment High-Density Cable:

Page 9: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

8www.huawei.com • Huawei Confidential

Configuration parameter

Note:If you find that some options listed in compatibility list are not in the configurator ( Unistar), then

you need to add them manually and we suggest you to check the configuration with the product SE.

Page 10: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

9www.huawei.com • Huawei Confidential

Content

1

2

3

Configuration Parameter Introduction

Quotation Entrance

Example

Page 11: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

10www.huawei.com • Huawei Confidential

Configuration Quotation Entrance

1. http://app.huawei.com/unistar/sct/login!loginChoose.action

Choose User Login and enter the user name and password to log in.

Select a country (Australia as an example in this guide) in the upper left corner. Choose Product > IT >

Server, select High-Density servers. Then X6800 and X6800 Spares options are displayed. (The

X6800 Spares package is used to configure X6800 parts and is seldom used.) Click Add to Cart below

the X6800 icon. Then select X6800 in the upper right corner of the window and click Quote. The

quotation window is displayed.

Page 12: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

11www.huawei.com • Huawei Confidential

Configuration Quotation Entrance

3. Set basic information and click Save.

Page 13: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

12www.huawei.com • Huawei Confidential

Configuration Quotation Entrance

4. Select X6800. The quotation window is displayed.

Page 14: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

13www.huawei.com • Huawei Confidential

Configuration

1. Set parameters in the quotation window, including the node type, processor, CPU, memory, and hard

disk parameters.

Page 15: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

14www.huawei.com • Huawei Confidential

Content

1

2

3

Configuration Parameter Introduction

Quotation Entrance

Example

Page 16: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

15www.huawei.com • Huawei Confidential

Configuration ExampleExample::Eight XH620 V3 nodes in a chassis. Each node contains:2 x E5-2667 v3 processors, 16 x 16 GB

DIMMs, 2 x 900 GB 2.5-inch disks (RAID), 2 x PCIe cards (one for network port and one for PCIe SSD

storage), 2 x GE electrical ports, one USB flash drive, 2 x SATA DOMs, Linux OS, 4 x 1200 W power

supply units, 4 x high-density cables. Quotation as below:

Note:XH620 V3 supports up to three PCIe cards (of of which is an onboard RAID controller card). This time, each XH620 V3

node must be configured with two PCIe cards. Therefore, besides the PCIe slot at the front, the I/O module (eight PCIe

expansion slots) at the rear of the chassis is used. Set this parameter to 请选择机框类型.

Page 17: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

16www.huawei.com • Huawei Confidential

Hard disk

The row marked with red is not existed at the beginning, it appears after we choose “support back IO board” and YES to the “Need the back IO switch or not” for the chassis.

Page 18: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

17www.huawei.com • Huawei Confidential

Page 19: Huawei FusionServer X6800 Quotation Guide - ActForNet X6800 … ·  •Huawei Confidential 1 Content 1 Configuration Parameter Introduction 2 Quotation Entrance 3 Example

Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved.

The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product

portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive

statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time

without notice.

Thank youwww.huawei.com