huawei bsc6900 gsm parameter reference

1610
Parameter ID Parameter Name NE MML Command BSC6900 ABCUpQuality BSC6900 BSC6900 BSC6900 ABISFCEN BSC6900 AbisFCTimer1 BSC6900 AbisFCTimer2 BSC6900 BSC6900 BSC6900 BSC6900 BSC6900 ABISTSFREETM BSC6900 ABCDownQualit y Quality Threshold in Assigning Better Cell SET GCELLHOAD(Opt ional) Uplink Quality Threshold in Assigning Better Cell SET GCELLHOAD(Opt ional) ABCWaitMaxTim e Maximum Better Cell Assigning Duration SET GCELLHOAD(Opt ional) ABISBYPASSMOD E Abis ByPass Mode ADD BTS(Optional) SDCCH Congestion Flow Control Allowed SET GCELLCCCH(Opt ional) Abis Flow Control Timer 1 SET BSCTMR(Option al) Abis Flow Control Timer 2 SET BSCTMR(Option al) ABISIDLETSALL OC Abis Idle TS Allocate Strategy SET BTSOTHPARA(Op tional) ABISIDLETSCFG SWITCH Abis Idle TS Configure Switch SET BTSOTHPARA(Op tional) AbisJamThresh old2StartLs Abis Jam Rate for BTS Local Switch SET BSSLS(Optiona l) ABISRESADJTCH HFUNSW TCHH Function Switch SET BTSFLEXABISPA RA(Optional) Timer of Releasing Abis Timeslot SET GCELLPSCHM(Op tional)

Upload: rizal011188412

Post on 20-Oct-2015

811 views

Category:

Documents


53 download

DESCRIPTION

Huawei BSC6900 GSM parameter reference

TRANSCRIPT

Parameter ListParameter IDParameter NameNEMML CommandMeaningFeature IDFeature NameValue TypeGUI Value RangeActual Value RangeUnitDefault ValueRecommended ValueImpactParameter RelationshipAccessService Interrupted After ModificationInterruption ScopeInterruption Duration(Min)CautionValidation of ModificationImpact on Radio Network PerformanceIntroduced in VersionAttributeABCDownQualityDownlink Quality Threshold in Assigning Better CellBSC6900SET GCELLHOAD(Optional)Downlink quality level threshold for the MS to be assigned with a channel of the better cell.GBFD-110502Assignment and Immediate AssignmentInterval Type0~700~70None5050CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.The smaller the value of this parameter is, the more MSs select a neighboring cell in directed retry.BSC6900 V900R011RadioABCUpQualityUplink Quality Threshold in Assigning Better CellBSC6900SET GCELLHOAD(Optional)Uplink quality level threshold for the MS to be assigned with a channel of the better cell.GBFD-110502Assignment and Immediate AssignmentInterval Type0~700~70None5050CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.The smaller the value of this parameter is, the more MSs select a neighboring cell in directed retry.BSC6900 V900R011RadioABCWaitMaxTimeMaximum Better Cell Assigning DurationBSC6900SET GCELLHOAD(Optional)The maximum duration for the BSC to select the best cell according to MRs in the MS assigning procedure. The BSC assigns the channel of the serving cell to the MS if the best cell is not selected within the duration specified by this parameter.GBFD-110502Assignment and Immediate AssignmentInterval Type10~801~8, step:0.1s4040CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThe value of this parameter must be greater than five times the maximum value of the following parameter: "Filter Length for SDCCH Level", "Filter Length for SDCCH Qual", "Filter Length for TCH Level", "Filter Length for TCH Qual", "Filter Length for TA", "TA filter length for SDCCH level". If the parameter "IBCA Allowed" is set to YES, then the value of this parameter must be greater than five times the value of "IBCA Assign Waiting Mr Time". If the parameter Waiting for "MR on SDCCH Switch" is set to YES, then the value of this parameter must be greater than the value of "Duration for Waiting MR on SDCCH".The parameter modification has no impact on the equipment.The setting of this parameter affects the access delay of parts of MSs.BSC6900 V900R011RadioABISBYPASSMODEAbis ByPass ModeBSC6900ADD BTS(Optional)Whether to enable the BTS to support bypass function. HDLC BTS and IP BTS do not support this parameter.GBFD-116601Abis BypassEnumeration TypeTRUE(Support), FALSE(Not Support)TRUE, FALSENoneBTSNoneRead & WriteYBTSLess than 5 minutesNoneThe BTS should be reset to validate the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentABISFCENSDCCH Congestion Flow Control AllowedBSC6900SET GCELLCCCH(Optional)Whether to permit Abis flow control.The flow control function helps in better call management. If congestion occurs, the system lightens its load by rejecting some services or prolonging the time for service requests. The Abis flow control is used to lighten the system load caused by Abis flows.GBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAbisFCTimer1Abis Flow Control Timer 1BSC6900SET BSCTMR(Optional)Used along with "Abis Flow Control Timer 2" to control the change in cell flow control levels.When the flow control level in the cell changes, the values of MS MAX Retrans and Tx-integer in the system information are changed accordingly. When immediate assignment fails, the BSC6900 starts T1 and T2.GBFD-111705GSM Flow ControlInterval Type10~25510~255s3030BSCThe value of this parameter should be smaller than "AbisFCTimer2".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAbisFCTimer2Abis Flow Control Timer 2BSC6900SET BSCTMR(Optional)Used along with "Abis Flow Control Timer 1" to control the change in cell flow control levels.When the flow control level in the cell changes, the values of MS MAX Retrans and Tx-integer in the system information are changed accordingly. When immediate assignment fails, the BSC6900 starts T1 and T2.GBFD-111705GSM Flow ControlInterval Type10~25510~255s6060BSCThe value of this parameter should be greater than "AbisFCTimer1".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentABISIDLETSALLOCAbis Idle TS Allocate StrategyBSC6900SET BTSOTHPARA(Optional)This parameter controls the strategy for idle timeslot selection and optimization by the PS channels.GBFD-114201EGPRSEnumeration TypeIDLETSALLOC_0(Any idle timeslots under the same site), IDLETSALLOC_1(Idle timeslots on same E1 primary link preferred), IDLETSALLOC_2(Idle timeslots on same E1 primary link only), IDLETSALLOC_3(Idle timeslots on same 64K primary link only)IDLETSALLOC_0, IDLETSALLOC_1, IDLETSALLOC_2, IDLETSALLOC_3NoneIDLETSALLOC_OIDLETSALLOC_OBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011TransportABISIDLETSCFGSWITCHAbis Idle TS Configure SwitchBSC6900SET BTSOTHPARA(Optional)This parameter controls whether the strategy for timeslot configuration and optimization is started. When this parameter is set to ON, the bundled idle timeslots for the PS channel should be allocated to the same 64 kbit/s timeslot as the primary link. When this parameter is set to OFF, the idle channels are allocated randomly in the transport pool of a site.GBFD-114201EGPRSEnumeration TypeCLOSE(CLOSE), OPEN(OPEN)CLOSE, OPENNoneCLOSECLOSEBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThis parameter should be set to ON when the transmission delays of different 64 kbit/s timeslots are different over the Abis interface in TDM transmission mode. Different transmission delays usually occur in the DXX network mode or when the transmission paths of multiple E1 links are different under the same site.The parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011TransportAbisJamThreshold2StartLsAbis Jam Rate for BTS Local SwitchBSC6900SET BSSLS(Optional)Threshold for enabling the BTS local switching. When the congestion rate at the Abis interface exceeds this threshold, the BTS local switching is enabled.GBFD-117702BTS Local SwitchInterval Type0~1000~100per cent9090BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentABISRESADJTCHHFUNSWTCHH Function SwitchBSC6900SET BTSFLEXABISPARA(Optional)This parameter specifies whether to enable the Abis resource adjustment TCHH function.It specifies whether the TCHH is preferentially allocated to the MS by the BSC6900 when Abis resources are insufficient.If the Abis resource load is greater than "Flex Abis Prior Choose Load Thred" or "Fix Abis Prior Choose Abis Load Thred" when the parameter is set to "YES", the BSC6900 preferentially allocates the TCHH to the MS.GBFD-117301Flex AbisEnumeration TypeNO(NO), YES(YES)NO, YESNoneNONOBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentABISTSFREETMTimer of Releasing Abis TimeslotBSC6900SET GCELLPSCHM(Optional)Interval between detection of the Abis timeslot being in idle state and releasing of the Abis timeslot. When channels are idle, the timer is started. When the timer expires, the Abis timeslot is released. When all the TBFs on the channel are released, the Abis timeslot is not released at once. Instead, the timer is started when the channels are idle. Before the timer expires, if new service request is received and the Abis timeslot is occupied, then the timer is stopped; otherwise, the timeslot is released after the timer expires.When "Number of Dynamic Channel Pre-Converted" is greater than 0, the Abis timeslots are not released after the static PDCH and pre-converted PDCH are idle.GBFD-113101PDCH Dynamic AdjustmentInterval Type10~360010~3600s1515CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAbisVerAbis Interface TagBSC6900SET BSCBASIC(Optional)Phase tag for GSM protocols that the Abis interface supportsMRFD-210301Configuration ManagementEnumeration TypeGSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2PlusGSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2PlusNoneGSM_PHASE_2It is recommended that the value of this parameter is the same as that for "A Interface Tag".BSCThe value of this parameter is the same as those of "Um Interface Tag" and "A Interface Tag".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioABLASTTIMEDuration of BTS Collecting AB[100 Millisecond]BSC6900ADD AISSCFG(Optional)Duration available for the BTS to collect the AB after the TRX or channel is activatedGBFD-118201Soft-Synchronized NetworkInterval Type1~2551~255None4040BSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioAbnormalMosThresholdAbnormal Voice MOS ThresholdBSC6900SET OTHSOFTPARA(Optional)Mean opinion score (threshold) for judging an abnormal call. The BTS computes the MOS of a call periodically and reports the call MOS to the BSC in custom measurement reports. According to the call MOS, the BSC checks whether the call is normal. If the call MOS is less than this threshold, the BSC considers the call abnormal and records the abnormity in the call history record (CHR).To prevent the impact of a decimal fraction, set this parameter to the product of 50 and the actual MOS.GBFD-116801Voice Quality Index (Uplink VQI)Interval Type0~2500~250None100100BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedIf this parameter is set too high, a normal voice may be considered abnormal. If this parameter is set too low, an abnormal voice may not be considered.The parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentACCBURSTAccess Burst TypeBSC6900SET GCELLPSBASE(Optional)Access pulse type of the PRACH, uplink PTCCH and packet control acknowledge message of the MS.8bit: 8 bit pulse access mode; 11bit: 11 bit pulse access mode.GBFD-119110AccessEnumeration Type8BIT(8BIT), 11BIT(11BIT)8BIT, 11BITNone8BIT8BITCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioACCCONTROLCLASSAccess Control ClassBSC6900SET GCELLPRACH(Optional)Access control class of the MSGBFD-119110AccessInterval Type0~655350~65535None00CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioACCESSOPTILAYIncoming-to-BSC HO Optimum LayerBSC6900SET GCELLHOIUO(Optional)Subcell preferred during the incoming inter-BSC handover to the concentric cell. In the case of incoming inter-BSC handover to the concentric cell, the channels in this subcell are preferred.GBFD-113201Concentric CellEnumeration TypeOSubcell(Overlaid subcell), USubcell(Underlaid subcell), NoPrefer(No preference)OSubcell, USubcell, NoPreferNoneUsubcellUsubcellCellThis parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAccStaServiceTypePS Initial Access Service TypeBSC6900SET GCELLPSOTHERPARA(Optional)Whether the initial service is uplink, downlink or neutralGBFD-119501Adaptive Adjustment of Uplink and Downlink ChannelsEnumeration TypeULPRIORITY(Uplink Priority), NEUTRAL(Neutral Priority), DLPRIORITY(Downlink Priority)ULPRIORITY, NEUTRAL, DLPRIORITYNoneNEUTRALNEUTRALCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.The throughput is affected.Versions earlier than BSC6900 V900R011RadioACFCAddress and control field compressBSC6900ADD PPPLNK(Optional)ADD MPGRP(Optional)Whether to compress the address and control fields. If this parameter is set to ENABLE, the address and control area compression is enabled. If this parameter is set to DISABLE, the address and control area compression is disabled.GBFD-118611GBFD-118622Abis IP over E1/T1A IP over E1/T1Enumeration TypeDisable(Disable), Enable(Enable)Disable, EnableNoneEnableEnablePPP linkNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011TransportACFCSupport Address and Control Field CompressBSC6900ADD BTSPPPLNK(Optional)ADD BTSMPGRP(Optional)A flag bit indicates Whether to support the compression of the address and control fields.GBFD-118611Abis IP over E1/T1Enumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESBTSNoneRead & WriteYPPP linkLess than 5 minutesNoneThe transport path should be re-established after the parameter modification.NoneVersions earlier than BSC6900 V900R011TransportACOOPERATPAGINGSWITCHA Interface Paging Co-ordination SwitchBSC6900SET BSCPSSOFTPARA(Optional)This parameter specifies whether to receive the CS paging request from A interface when the MS uses a PS service. This parameter is used to control the paging collaboration function of A interface of the entire BSC. This parameter specifies whether to forward the paging message of the A interface from the circuit domain to the PS domain .GBFD-119305BSS Paging CoordinationEnumeration TypeCLOSE(Close), OPEN(Open)CLOSE, OPENNoneCLOSECLOSEBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThis parameter is valid only when "BSSPAGINGCOORDINATION" in "SET GCELLPSBASE" is set to YES.The parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioACSAdditional Reselect Parameter IndicationBSC6900SET GCELLIDLEAD(Optional)Used for notifying MSs where to retrieve relevant parameters during cell reselection.The default value of this parameter is 0 in system message 3 and, has no special significance.In system message 4, if the value of this parameter is 0, it means that the MSs must retrieve the PI parameters and other parameters relevant to cell reselection and the parameters relevant to C2 calculation from the remaining bytes of system message 4.If the value is 1, it means that the MS must retrieve the parameters from the remaining bytes of system message 7 or 8.GBFD-110402Basic Cell Re-selectionEnumeration TypeCOMPUL0(Compulsory 0), COMPUL1(Compulsory 1), FLEX(Flexible)COMPUL0, COMPUL1, FLEXNoneFLEXFLEXCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedACS is usually set to 0 because system information 7 and 8 messages are seldom used in common cells. ACS should be set to 1 if system information 7 and 8 messages are used in a cell and C2 is used for cell reselection.The parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioACTCDSETFAMR ACS[F]BSC6900SET GCELLCCAMR(Optional)Active coding set (ACS)[F], indicates a set of full-rate coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates.GBFD-115501AMR FRBit Field Type4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3 7_40KBIT/S~4 7_95KBIT/S~5 10_2KBIT/S~6 12_2KBIT/S4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S, 7_40KBIT/S, 7_95KBIT/S, 10_2KBIT/S, 12_2KBIT/SNone4_75KBIT/S-1&5_15KBIT/S-0&5_90KBIT/S-1&6_70KBIT/S-0&7_40KBIT/S-1&7_95KBIT/S-0&10_2KBIT/S-0&12_2KBIT/S-14_75KBIT/S-1&5_15KBIT/S-0&5_90KBIT/S-1&6_70KBIT/S-0&7_40KBIT/S-1&7_95KBIT/S-0&10_2KBIT/S-0&12_2KBIT/S-1CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThe number of the chosen data rates must be from one to four. If this parameter involves only one full rate coding rate, the value of "AMR Starting Mode[F]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[F]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[F]", "AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", and "AMR DL Coding Rate adj.hyst1[F]".If this parameter involves three coding rates, the value of "AMR Starting Mode[F]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[F]", "AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", "AMR DL Coding Rate adj.hyst1[F]", "AMR UL Coding Rate adj.th2[F]", "AMR UL Coding Rate adj.hyst2[F]", "AMR DL Coding Rate adj.th2[F]", and "AMR DL Coding Rate adj.hyst2[F]".If this parameter involves four full rate coding rates, the value of "AMR Starting Mode[F]" can be 0, 1, 2, and 3; all the adjustable thresholds and hysteresis of AMR coding rate make sense.The parameter modification has no impact on the equipment.The ACS may affect the MOS.Versions earlier than BSC6900 V900R011RadioACTCDSETHAMR ACS[H]BSC6900SET GCELLCCAMR(Optional)Active coding set (ACS)[H], indicates set of half-rate coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates.GBFD-115502AMR HRBit Field Type4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3 7_40KBIT/S~4 7_95KBIT/S4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S, 7_40KBIT/S, 7_95KBIT/SNone4_75KBIT/S-1&5_15KBIT/S-0&5_90KBIT/S-1&6_70KBIT/S-0&7_40KBIT/S-1&7_95KBIT/S-04_75KBIT/S-1&5_15KBIT/S-0&5_90KBIT/S-1&6_70KBIT/S-0&7_40KBIT/S-1&7_95KBIT/S-0CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThe number of the chosen data rates must be from one to four. If this parameter involves only one half rate coding rate, the value of "AMR Starting Mode[H]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[H]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]", and "AMR DL Coding Rate adj.hyst1[H]".If this parameter involves three coding rates, the value of "AMR Starting Mode[H]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]", "AMR DL Coding Rate adj.hyst1[H]", "AMR UL Coding Rate adj.th2[H]", "AMR UL Coding Rate adj.hyst2[H]", "AMR DL Coding Rate adj.th2[H]", and "AMR DL Coding Rate adj.hyst2[H]".If this parameter involves four half rate coding rates, the value of "AMR Starting Mode[H]" can be 0, 1, 2, and 3; all the adjustable thresholds and hysteresis of AMR coding rate make sense.The parameter modification has no impact on the equipment.The ACS may affect the MOS.Versions earlier than BSC6900 V900R011RadioACTCDSETWBAMR ACS[WB]BSC6900SET GCELLCCAMR(Optional)Active coding set (ACS)[WB], indicates a set of wide-band coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates.GBFD-115507WB AMRBit Field Type6_60KBIT/S, 8_85KBIT/S, 12_65KBIT/S0~7None6_60KBIT/S-1&8_85KBIT/S-1&12_65KBIT/S-16_60KBIT/S-1&8_85KBIT/S-1&12_65KBIT/S-1CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedThe number of the chosen data rates must be from one to three. If this parameter involves only one coding rate, the value of "AMR Starting Mode[WB]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[WB]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate adj.th1[WB]", and "AMR DL Coding Rate adj.hyst1[WB]".If this parameter involves three coding rates, the value of "AMR Starting Mode[WB]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate adj.th1[WB]", "AMR DL Coding Rate adj.hyst1[WB]", "AMR UL Coding Rate adj.th2[WB]", "AMR UL Coding Rate adj.hyst2[WB]", "AMR DL Coding Rate adj.th2[WB]", and "AMR DL Coding Rate adj.hyst2[WB]".The parameter modification has no impact on the equipment.The ACS may affect the MOS.Versions earlier than BSC6900 V900R011RadioACTL2REESTActivate L2 Re-establishmentBSC6900SET GCELLSOFT(Optional)Whether to activate the function of L2 re-establishment. If this function is activated, the BSC starts the attempt of L2 re-establishment when the BSC receives an ERR IND message reported by the BTS in a conversation of MSs. If the L2 re-establishment succeeds, the conversation continues; otherwise, a call drop occurs.GBFD-110501Call ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneNONOCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentACTTIMEValid Time of BTS Resource ActivationBSC6900ADD AISSCFG(Optional)Valid duration of the reserved TRX or timeslotGBFD-118201Soft-Synchronized NetworkInterval Type1~2551~255min1010BSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioACVLTHDAC Voltage Lower ThresholdBSC6900SET BTSAPMUBP(Optional)AC voltage alarm lower threshold. When the input AC voltage is lower than the value of this parameter, an alarm indicating the abnormal AC is reported.In multi-mode scenario, the value of this parameter in one mode must be the same as the value of the corresponding parameter in another mode.GBFD-111202O&M of BTSInterval Type60~30060~300V180180BTSThe value of this parameter must be smaller than "AC Voltage Upper Threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentACVOLALARMHAC Overvoltage Alarm ThresholdBSC6900SET BTSDPMUBP(Optional)The BTS reports an alarm if the AC voltage exceeds the value of this parameter.GBFD-111202O&M of BTSInterval Type610~300061.0~300.0 (step: 0.1)V28002800BTSThe value of this parameter must be greater than "AC undervoltage alarm threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentACVOLALARMLAC Undervoltage Alarm ThresholdBSC6900SET BTSDPMUBP(Optional)The BTS reports an alarm if the AC voltage is lower than the value of this parameter.GBFD-111202O&M of BTSInterval Type600~299060.0~299.0 (step: 0.1)V18001800BTSThe value of this parameter must be smaller than "AC overvoltage alarm threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentACVUTHDAC Voltage Upper ThresholdBSC6900SET BTSAPMUBP(Optional)The BTS reports an alarm if the AC voltage exceeds the value of the AC voltage alarm upper threshold. When the input AC voltage is higher than the value of this parameter, an alarm indicating the abnormal AC is reported.In multi-mode scenario, the value of this parameter must be the same as the value of the parameter in other modes.GBFD-111202O&M of BTSInterval Type60~30060~300V280280BTSThe value of this parameter must be greater than "AC Voltage Lower Threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentADAPTASSIGNMENTFLOWAssignment Procedure in Intra-Cell HO AllowedBSC6900SET GCELLSOFT(Optional)Whether to hand over an MS to another channel during an intra-cell handover through the assignment processGBFD-110601GBFD-510501HUAWEI I HandoverHUAWEI II HandoverEnumeration TypeNO(No), YES(Yes)NO, YESNoneNONOCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.The switching from an intra-cell handover procedure to an assignment procedure shortens the duration of the intra-cell handover.Versions earlier than BSC6900 V900R011RadioADDRCommunication AddressBSC6900SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional)Communication address of the CBUS3 on the bus 485. The configuration of this parameter must be consistent with the actual physical connection. Otherwise, the board may not work properly.GBFD-111202O&M of BTSInterval Type0~2540~254NoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAddTransBwIntSub-Link Bandwidth Request Interval When Not CongestedBSC6900SET BSCPSSOFTPARA(Optional)Interval for requesting the bandwidth for the secondary link when the system is not in congestion stateGBFD-111705GSM Flow ControlInterval Type0~500~50ms00BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioAddTransBwNumBandwidth for Secondary Link When Not CongestedBSC6900SET BSCPSSOFTPARA(Optional)Bandwidth requested each time for the secondary link when the system is not in congestion stateGBFD-111705GSM Flow ControlInterval Type0~7680~768None22BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioADJBSCDPCAdjacent BSC DPCBSC6900ADD EXTNCELL(Mandatory)COL BSCSYNCINFO(Mandatory)The destination signaling point (DSP) of the adjacent BSC must be an Iur-g DSP.GBFD-111804A Interface Protocol ProcessInterval Type1~167772151~16777215NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011TransportADJMODEAdjustment ModeBSC6900SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory)Whether to adjust the BTS offset manually or automaticallyGBFD-118201Soft-Synchronized NetworkEnumeration TypeBYMANUAL(By Manual), BYAUTO(By Auto)BYMANUAL, BYAUTONoneBYAUTONoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentADJUSTULMCSTYPESupport EGPRS Uplink MCS Dynamic AdjustBSC6900SET GCELLEGPRSPARA(Optional)Mode of dynamically adjusting the EGPRS uplink encoding scheme. Value 0 indicates dynamic adjustment of EGPRS uplink coding scheme is not supported; value 1 indicates that the uplink coding scheme is adjusted according to downlink quality measurements reported by MS; value 2 indicates that the uplink coding scheme is adjusted according to uplink quality measurements reported by BTS.GBFD-119204Dynamically Adjusting the Uplink MCS CodingEnumeration Type0(Not support dynamic adjustment), 1(According to downlink quality measurements reported by MS), 2(According to uplink quality measurements reported by BTS)0, 1, 2None22CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioADLDACTAuto Download Active Function SwitchBSC6900SET BTSAUTODLDACTINFO(Optional)This parameter specifies whether to enable the BTS software auto-loading and auto-activation function. If this parameter is set to Yes, the BTS software is automatically loaded and activated when the BTS is initialized, when it is time for the BSC to perform the resource check, and when a board is added. If this parameter is set to Yes, the BTS software fails to be forcibly loaded and activated. If this parameter is set to No, the BTS software can be successfully forcibly loaded and activated.GBFD-111202O&M of BTSEnumeration TypeOFF(OFF), ON(ON)OFF, ONNoneOFFOFFBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentADMODEAuto Download ModeBSC6900SET BTSAUTODLDACTINFO(Optional)This parameter specifies the automatic load mode of the BTS software. If this parameter is set to common download, common loading is performed on the OML/EML, and the link is not extended. If this parameter is set to quick download(without traffic), quick loading can be performed on the dynamically extended link besides the OML/EML. This may affect the services in the cell. If this parameter is set to quick download(reserve BCCH Trx traffic), quick loading can be performed on the dynamically extended link besides the OML/EML. This should not affect the services on the main BCCH TRX of the cell.GBFD-111202O&M of BTSEnumeration TypeCOMMON_DLD(Common Download), QUICK_DLD1(Quick Download No Traffic), QUICK_DLD2(Quick Download Reserve BCCH)COMMON_DLD, QUICK_DLD1, QUICK_DLD2NoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentADMSTATAdministrative StateBSC6900SET GCELLADMSTAT(Mandatory)Administrative state of a cellGBFD-111202O&M of BTSEnumeration TypeLOCK(Lock), UNLOCK(Unlock), SHUTDOWN(Shutdown)Lock, Unlock, ShutdownNoneUNLOCKUNLOCKCellNoneRead & WriteN (No impact on the UE in idle mode)CellThe services are disrupted until this parameter is set to Unlock.NoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentADMSTATAdministrative StateBSC6900SET GTRXADMSTAT(Mandatory)Administrative state of the TRXGBFD-111202O&M of BTSEnumeration TypeLock(Lock), Unlock(Unlock), Shutdown(Shutdown)Lock, Unlock, ShutdownNoneUnlockUnlockTRXNoneRead & WriteIf the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the corresponding TRX to another TRX. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdown", the ongoing services are not affected but new service accesses are not allowed.TRXServices will be disrupted until the value of this parameter is changed to "Unlock".NoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentADMSTATAdministrative StateBSC6900SET GTRXCHANADMSTAT(Mandatory)Administrative state of the channelGBFD-111202O&M of BTSEnumeration TypeLock(Lock), Unlock(Unlock), Shutdown(Shutdown)Lock, Unlock, ShutdownNoneUnlockUnlockCurrent BFD sessionNoneRead & WriteIf the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the corresponding channel to another channel. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdown", the ongoing services are not affected but new service accesses are not allowed.ChannelServices will be disrupted until the value of this parameter is changed to "Unlock".NoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentADTETOffset Time Adjustment End TimeBSC6900ADD AISSCFG(Optional)End time for adjusting the offset timeGBFD-118201Soft-Synchronized NetworkCompound Typehour, minhour{0~23}min{0~59}NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioADTLODLoad Threshold of Offset AdjustmentBSC6900ADD AISSCFG(Optional)Cell load threshold for adjusting the offset time. If the load threshold is exceeded, the offset time is not adjusted.GBFD-118201Soft-Synchronized NetworkInterval Type0~1000~100None1010BSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioADTONOffset Time Adjustment SwitchBSC6900ADD AISSCFG(Mandatory)Offset Time Adjustment SwitchGBFD-118201Soft-Synchronized NetworkEnumeration TypeOFF(OFF), ON(ON)OFF, ONNoneOFFOFFBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioADTSTOffset Time Adjustment Start TimeBSC6900ADD AISSCFG(Optional)Start time for adjusting the offset timeGBFD-118201Soft-Synchronized NetworkCompound Typehour, minhour{0~23}min{0~59}NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioADVALMMGRULETPAdvanced Alarm Management Rule TypeBSC6900ADD BTSALMMGMRULE(Mandatory)Advanced alarm management rule typeMRFD-210304Faulty ManagementEnumeration TypeRATIORULE(Ratio Rule)RATIORULENoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentADVER1BTS Software Version 1BSC6900SET BTSAUTODLDACTINFO(Optional)This parameter specifies the software version 1 that is automatically loaded and activated. The version of the BTS software stored on the OMU must be consistent with this version number. Otherwise, a software version inconsistency alarm is reported. The BTSs may work in hybrid combined cabinets and cabinet groups mode, therefore, two software versions with different version numbers are designed. The second software version can be configured only when the first one has been configured. The second software version is specified by the parameter BTS Version 2. An example of the version format is as follows: BTS3000V100R008C11SPC003.This parameter can be set to only a BTS software version or a cold patch version. You can use either of the following methods to query the version number of the BTS software or the cold patch.Method 1: If the BTS software or the cold patch is downloaded to the OMU through the MML command DLD BTSSW, you can run the MML command LST BTSSW to obtain the number of the version to be loaded according to the returned result.Method 2: If the BTS software version or the cold patch is not downloaded to the OMU, you can decompress the BTS software package or cold patch package. Then, check the vercfg.xml file in the level-1 directory of the compressed package. The value after the label "SoftwareVersion" is the software version.GBFD-111202O&M of BTSString TypeNone1~51 charactersNoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentADVER2BTS Software Version 2BSC6900SET BTSAUTODLDACTINFO(Optional)This parameter specifies the software version 2 that is automatically loaded and activated. The BTS software stored on the OMU must be consistent with this version number. Otherwise, the software version inconsistency alarm may be reported. The BTSs may work in hybrid combined cabinets and cabinet groups mode, therefore, two software versions with different version numbers are designed. This parameter can be configured only when the parameter BTS Version 1 has been configured. An example of the version format is as follows: BTS3000V100R008C11SPC003. This parameter can be set to only a BTS software version or a cold patch version. You can use either of the following methods to query the version number of the BTS software or the cold patch.Method 1: If the BTS software or the cold patch is downloaded to the OMU through the MML command DLD BTSSW, you can run the MML command LST BTSSW to obtain the number of the version to be loaded according to the returned result.Method 2: If the BTS software version or the cold patch is not downloaded to the OMU, you can decompress the BTS software package or cold patch package. Then, check the vercfg.xml file in the level-1 directory of the compressed package. The value after the label "SoftwareVersion" is the software version.GBFD-111202O&M of BTSString TypeNone1~51 charactersNoneNoneNoneBTSThis parameter can be configured only when "BTS Software Version 1" is configured.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAEC_Echo_Path_DelayAEC Echo Path DelayBSC6900SET TCPARA(Optional)If the echo path is traced, the echo is judged and controlled according to the trace result of the echo path parameters. Otherwise, the echo is judged and controlled according to the recommended value.GBFD-115602Acoustic Echo Cancellation(AEC)Interval Type0~6000~600ms400400BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentAEC_Echo_Return_LossAEC Echo Return LossBSC6900SET TCPARA(Optional)This parameter is used for echo judgment and control when the echo parameters are not traced.GBFD-115602Acoustic Echo Cancellation(AEC)Interval Type0~600~60dB2020BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentAEC_Nlp_GateAEC Nlp GateBSC6900SET TCPARA(Optional)If the local input voltage is lower than the value of this parameter and the remote end transmits the voice signal, the AEC function uses the comfort noise to replace the minor echo. In this case, the speech signals at low level may also be cut.GBFD-115602Acoustic Echo Cancellation(AEC)Interval Type-60~-35,0-60~-35, 0dBm-48-48BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentAEC_Path_DelayAEC Path DelayBSC6900SET TCPARA(Optional)Extra delay due to the transmission line. This parameter should be set according to the actual conditions and is applicable to satellite transmission.GBFD-115602Acoustic Echo Cancellation(AEC)Interval Type0~10000~1000ms00BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentAEC_SNR_GateAEC SNR GateBSC6900SET TCPARA(Optional)This parameter is used to determine whether there are speech signals at the local end. If the local SNR is lower than the value of this parameter, echo control is not performed.GBFD-115602Acoustic Echo Cancellation(AEC)Interval Type0~150~15dB66BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be re-established after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentAEC_SwitchAEC SwitchBSC6900SET TCPARA(Optional)This parameter indicates whether the acoustic echo cancellation (AEC) functional switch is on or off.GBFD-115602Acoustic Echo Cancellation(AEC)Enumeration TypeCLOSE(Close), OPEN(Open)CLOSE, OPENNoneCLOSECLOSEBoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be re-established after the parameter modification.If this parameter is set to OPEN, the acoustic echo can be cancelled to improve the speech quality.Versions earlier than BSC6900 V900R011EquipmentAECDetectThresholdAEC Detect ThresholdBSC6900SET TCPARA(Optional)Threshold for detecting the AEC performanceGBFD-115602Acoustic Echo Cancellation(AEC)Interval Type10~10010~100None2020BoardIf the number of echo cancellations performed by AEC exceeds "AEC Detect Threshold" within the time specified by "AEC Detect Time", the TFO is closed forcibly.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneBSC6900 V900R011EquipmentAECDetectTimeAEC Detect TimeBSC6900SET TCPARA(Optional)Time for detecting the AEC performanceGBFD-115602Acoustic Echo Cancellation(AEC)Interval Type1~101~10s44BoardIf the number of echo cancellations performed by AEC exceeds "AEC Detect Threshold" within the time specified by "AEC Detect Time", the TFO is closed forcibly.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneBSC6900 V900R011EquipmentAFRDSBLCNTAFR Radio Link TimeoutBSC6900SET GCELLCCBASIC(Optional)Counter for radio link failures during an AMR full rate call. See the description of "Radio Link Timeout" in "SET GCELLCCBASIC".GBFD-115505AMR Wireless Link TimerEnumeration Type4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times1920~30720, step:480ms64_Times64_TimesCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedWith a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link Timeout".The parameter modification has no impact on the equipment.If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.Versions earlier than BSC6900 V900R011RadioAFRSAMULFRMAFR SACCH Multi-FramesBSC6900SET GCELLCCBASIC(Optional)Number of SACCH multiframes during an AMR full rate call. See the description of "SACCH Multi-Frames" in "SET GCELLCCBASIC".GBFD-115505AMR Wireless Link TimerInterval Type0~630~30240, step:480ms4848CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedWith a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH Multi-Frames".The parameter modification has no impact on the equipment.If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.Versions earlier than BSC6900 V900R011RadioAGPSRECEIVERIDGPS IDBSC6900ADD GPS(Mandatory)GPS receiver IDNoneNoneInterval Type0~655340~65534NoneNoneNoneNoneNoneRead & WriteNot involvedNot involvedNot involvedThe parameter cannot be modified.Not involvedNoneVersions earlier than BSC6900 V900R011EquipmentAGPSRECEIVERTYPEGPS typeBSC6900ADD GPS(Mandatory)GPS receiver type.NoneNoneEnumeration TypeBSC(BSC)BSCNoneNoneNoneBoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.Not involvedBSC6900 V900R011EquipmentAHRDSBLCNTAHR Radio Link TimeoutBSC6900SET GCELLCCBASIC(Optional)Counter for radio link failures during an AMR half rate call. See the description of "Radio Link Timeout" in "SET GCELLCCBASIC".GBFD-115505AMR Wireless Link TimerEnumeration Type4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times1920~30720, step:480ms52_Times52_TimesCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedWith a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link Timeout".The parameter modification has no impact on the equipment.If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.Versions earlier than BSC6900 V900R011RadioAHRSAMULFRMAHR SACCH Multi-FramesBSC6900SET GCELLCCBASIC(Optional)Number of SACCH multiframes during an AMR half rate call. See the description of "SACCH Multi-Frames" in "SET GCELLCCBASIC".GBFD-115505AMR Wireless Link TimerInterval Type0~630~30240, step:480ms3232CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedWith a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH Multi-Frames".The parameter modification has no impact on the equipment.If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase.Versions earlier than BSC6900 V900R011RadioAIDAlarm IDBSC6900SET ALMPORT(Mandatory)Alarm IDMRFD-210304Faulty ManagementInterval Type65334~6538365334~65383NoneNoneNoneNoneNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm IDBSC6900SET ALMBLKPARA(Mandatory)Alarm IDMRFD-210304Faulty ManagementInterval Type1~655351~65535NoneNoneNoneNoneNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm IDBSC6900SET ALMLVL(Mandatory)SET ALMSHLD(Mandatory)SET BOXRPT(Mandatory)Identifier of the alarm. This parameter uniquely identifies an alarm.MRFD-210304Faulty ManagementInterval Type1~655351~65535NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm IDBSC6900ADD OBJALMSHLD(Optional)Identifier of the alarm. This parameter uniquely identifies an alarm.MRFD-210304Faulty ManagementInterval Type1~655351~65535NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm IDBSC6900SET ENVALMPARA(Mandatory)Identifier of the alarm. This parameter uniquely identifies an alarm.MRFD-210304Faulty ManagementInterval Type1~655351~65535NoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm ID.BSC6900SET BTSENVALMPORT(Optional)Alarm IDGBFD-111202O&M of BTSInterval Type65033~6553365033~65533NoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDAlarm ID.BSC6900ADD BTSOBJALMSHLD(Mandatory)Alarm IDMRFD-210304Faulty ManagementString TypeNone1~1024 charactersNoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDDELAYPROTECTTIMEAiding Delay Protect TimeBSC6900SET GCELLSOFT(Optional)Delay time for mutual-aid detection on a cell after the cell is initialized. When the cell initialization has just finished, the cell is in an unstable state. Mutual-aid detection at this time may cause a wrong decision. Therefore, this parameter is used for specifying proper delay.GBFD-113801TRX CooperationInterval Type1~601~60min1515CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedIf this parameter is set to a greater value, TRX mutual aid may not be triggered promptly in the case of BCCH TRX failure after a cell has just been initialized. If this parameter is set to smaller value, mutual aid may be decided mistakenly.The parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDSTAlarm Select TypeBSC6900ADD OBJALMSHLD(Optional)Type of alarm selectionMRFD-210304Faulty ManagementEnumeration TypeALL(All), ONEBYONE(One by One)ALL, ONEBYONENoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIDSTAlarm Select TypeBSC6900ADD BTSOBJALMSHLD(Mandatory)Alarm selection modeMRFD-210304Faulty ManagementEnumeration TypeALL(all), ONEBYONE(one by one)ALL, ONEBYONENoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAInterMsgTraceA Interface Msg [End2end User Tracing]BSC6900SET OTHSOFTPARA(Mandatory)Whether to trace A-interface messages during end-to-end user tracing. The end-to-end tracing is conducted throughout the network. The A-interface tracing results can be obtained from the MSC or BSC.GBFD-116401End-to-End MS Signaling TracingEnumeration TypeNO(No), YES(Yes)NO, YESNoneNONOBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCDISCLUENA IF FC Discard LOC UP EnableBSC6900SET BSCFCPARA(Optional)Whether to allow flow control for the location update services during the A interface flow controlGBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCDISCMOCENA IF FC Discard MOC EnableBSC6900SET BSCFCPARA(Optional)whether to allow flow control for the mobile-originated services during the A interface flow controlGBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCDISCMTCENA IF FC Discard MTC EnableBSC6900SET BSCFCPARA(Optional)Whether to allow flow control for the mobile-terminated services during the A interface flow controlGBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCDISCOSENA IF FC Discard Other Service EnableBSC6900SET BSCFCPARA(Optional)Whether to allow flow control for the other services including emergency call, call re-establish, and LMU services during the A interface flow controlGBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneYESYESBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCENA Interface Flow Control EnableBSC6900SET BSCFCPARA(Optional)Whether to enable the A interface flow control mechanism in the BSC6900GBFD-111705GSM Flow ControlEnumeration TypeNO(No), YES(Yes)NO, YESNoneNONOBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCMETHODA Interface Flow Control MethodBSC6900SET BSCFCPARA(Optional)Flow control method used by the BSC6900. Flow control method at the Abis interface: When receiving a channel request message, the BSC6900 begins flow control on the call according to the flow control level of the A interface. Flow control method at the A interface: When establishing an SCCP connection, the BSC6900 begins flow control according to the flow control level of the A interface and releases part of the call.GBFD-111705GSM Flow ControlEnumeration TypeABIS(Abis), A(A)ABIS, ANoneABISABISBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE1A IF FC Service Rate in Level 1BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 1 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent55BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE2A IF FC Service Rate in Level 2BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 2 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent55BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE3A IF FC Service Rate in Level 3BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 3 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent55BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE4A IF FC Service Rate in Level 4BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 4 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent1010BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE5A IF FC Service Rate in Level 5BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 5 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent1010BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAINTFFCRSRATE6A IF FC Service Rate in Level 6BSC6900SET BSCFCPARA(Optional)Rate of discarded services in level 6 of the A interface flow controlGBFD-111705GSM Flow ControlInterval Type0~1000~100per cent1010BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAIPCSDSRVRDNDLEVCSD Service Redundancy LevelBSC6900SET BSCBASIC(Optional)CSD service redundancy level, which is configured to decrease the data loss rate during transmission in A over IP mode.GBFD-118602A over IPEnumeration TypeNO(Not Supported), R3(Only R3 Supported), R2(Only R2 Supported), R2ANDR3(R2 And R3 Supported)NO, R3, R2, R2ANDR3NoneNoneNOBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentALC_Fix_GainALC Fix GainBSC6900SET TCPARA(Optional)Fixed gain value in fixed gain modeGBFD-115601Automatic Level Control (ALC)Interval Type-12~12-12~12dB66BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_Fix_Target_LevelALC Fix Target LevelBSC6900SET TCPARA(Optional)Target level in fixed level modeGBFD-115601Automatic Level Control (ALC)Interval Type-23~-4-23~-4dBm-18-18BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_Max_GainALC Max GainBSC6900SET TCPARA(Optional)This parameter restrains the maximum gain to the input signal. It is valid only when "ALC Mode" is "FIXEDLEVEL" or "ADAPTIVE". If the parameter is set to a small value, it may affect the conformance to the target level.GBFD-115601Automatic Level Control (ALC)Interval Type3~123~12dB66BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_Max_Target_LevelALC Max Target LevelBSC6900SET TCPARA(Optional)Maximum target level in adaptive ALC modeGBFD-115601Automatic Level Control (ALC)Interval Type-23~-4-23~-4dBm-4-4BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_Min_Target_LevelALC Min Target LevelBSC6900SET TCPARA(Optional)Mimumum target level in adaptive ALC modeGBFD-115601Automatic Level Control (ALC)Interval Type-23~-4-23~-4dBm-23-23BoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_ModeALC ModeBSC6900SET TCPARA(Optional)ALC level control modeGBFD-115601Automatic Level Control (ALC)Enumeration TypeFIXEDLEVEL(Fixed level mode), ADAPTIVE(Adaptive mode), FIXEDGAIN(Fixed gain mode)FIXEDLEVEL, ADAPTIVE, FIXEDGAINNoneFIXEDGAINFIXEDGAINBoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.NoneVersions earlier than BSC6900 V900R011EquipmentALC_SwitchALC SwitchBSC6900SET TCPARA(Optional)Whether to enable the adaptive level control (ALC) functionGBFD-115601Automatic Level Control (ALC)Enumeration TypeCLOSE(Close), OPEN(Open)CLOSE, OPENNoneCLOSECLOSEBoardNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe radio link should be reestablished after the parameter modification.If this parameter is set to OPEN, the voltage level can be adjusted automatically to improve the speech quality.Versions earlier than BSC6900 V900R011EquipmentALIVERETRYAlive RetryBSC6900SET BSCNSPARA(Optional)Retry times after the timer for the reply from the peer expires during the NSVC live test. If the reply is not received after the system resends the message according to retry times, the NSVC is regarded as faulty.GBFD-510002Gb Over FRInterval Type5~155~15None55BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALIVETIMERAlive TimerBSC6900SET BSCNSPARA(Optional)Duration of the timer to wait for the reply from the peer during the NSVC live testGBFD-510002Gb Over FRInterval Type1~2551~255s33BSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAllBwBandwidthBSC6900ADD RSCGRP(Mandatory)Specifies the bandwidth occupied when the " transmission resource group type " is IP and the " bandwidth mode " is HALF_DUPLEX.GBFD-118605IP QOSInterval Type0~40000000~4000000kbit/sNoneNoneTransmission resource groupWhen "BWMODE" in "ADD RSCGRP" is set to HALF_DUPLEX, this parameter is valid;if the "BWMODE" in "ADD RSCGRP" of upper class and lower class RSCGRP is set to HALF_DUPLEX, the "AllBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "AllBwE" in "ADD RSCGRP" of lower class RSCGRP;The "AllBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the sum of "TxBw" and "RxBw" in "ADD RSCGRP" of lower class RSCGRP.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011TransportALLOCDIFFTRXResource Reallocation to Different TrxBSC6900SET BSCPSSOFTPARA(Optional)Whether to reassign the TBF for a different TrxGBFD-114101GPRSEnumeration TypeNOTALLOW(Not Allow), ALLOW(Allow)NOTALLOW, ALLOWNoneALLOWALLOWBSCNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioALLOCSINGLEPDCHFORSIGNALLINGAllocate One PDCH for Signaling DataBSC6900SET GCELLPSCHM(Optional)When this parameter is set to ON, the GMM/SM signaling service is assigned only one PDCH; otherwise, the GMM/SM signaling service is assigned one or more PDCHs as required.GBFD-113101PDCH Dynamic AdjustmentEnumeration TypeOFF(OFF), ON(ON)OFF, ONNoneOFFOFFCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioALLOWAMRHALFRATEUSERPERCRatio of AMR-HRBSC6900SET GCELLCHMGBASIC(Optional)Maximum ratio of the number of AMR half rate channels to the total number of channels in a cell. When the resource allocation principle is determined by the BSC, no AMR half rate channel can be further assigned if the ratio of the number of AMR half rate channels to the total number of channels in the cell is greater than or equal to the value of this parameter. When the resource allocation principle is not determined by the BSC, radio resource allocation does not depend on the setting of this parameter.Total number of channels = number of half rate channels + number of full rate channels x 2GBFD-111005Enhanced Channel Assignment AlgorithmInterval Type0~1000~100per cent100100CellThe following condition must be met: "ALLOWAMRHALFRATEUSERPERC" = "ALLOWAMRHALFRATEUSERPERC".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioALLTSTYPETimeslot TypeBSC6900ADD AE1T1(Mandatory)Value ALLCIC indicates that all E1/T1 timeslots on the A interface must be set with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the A interface can be set with the value NULL.GBFD-111803A Interface Circuit ManagementEnumeration TypeALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null)ALLCIC, ALLNULLNoneNoneALLCICE1/T1 linkNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011TransportALLTSTYPETimeslot TypeBSC6900ADD PBE1T1(Optional)Value ALLCIC indicates that all E1/T1 timeslots on the PB interface must be set with the start CIC. Value ALLNULL indicates that all E1/T1 timeslots on the PB interface can be set with the value NULL.GBFD-111203O&M of BSCEnumeration TypeALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null)ALLCIC, ALLNULLNoneALLCICALLCICPBE1T1NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD0Feed Tri. 0 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 0 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD1Feed Tri. 1 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 1 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD2Feed Tri. 2 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 2 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD3Feed Tri. 3 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 3 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD4Feed Tri. 4 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 4 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMD5Feed Tri. 5 TMA Low Current Alarm ThreholdBSC6900SET BTSDATUBP(Optional)If the feed current of the TMA on tributary 5 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered.MRFD-210304Faulty ManagementInterval Type0~20000~2000mA3030BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMDISACDURAlarm Disappear Accumulate DurationBSC6900ADD BTSALMMGMRULE(Mandatory)Alarm clearance accumulated failure duration.Threshold for the accumulated duration in which the alarm persists. If the accumulated duration exceeds this threshold, an alarm is cleared. Otherwise, the alarm persists.MRFD-210304Faulty ManagementInterval Type0~655350~65535sNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentALMENABLEAlarm Enable FlagBSC6900SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional)Whether the configuration of alarm parameters is allowed.In multi-mode scenario, the value of this parameter must be the same as the value of the parameter in other modes.MRFD-210304Faulty ManagementEnumeration TypeNO(NO), YES(YES)NO, YESNoneYESYESBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAlmIdAlarm ID.BSC6900SET BTSALMFLASHTHD(Mandatory)ID of the intermittent alarm.MRFD-210304Faulty ManagementInterval Type0~655340~65534NoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentALMIDAlarm ID.BSC6900ADD BTSALMMGMRULE(Mandatory)Alarm IDMRFD-210304Faulty ManagementInterval Type0~655350~65535NoneNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentALMLMTDOWNLower AlarmBSC6900SET BTSDGPSBP(Optional)If the input current of the antenna feeder is smaller than the value of this parameter, an alarm related to the GPS antenna is reported.MRFD-210304Faulty ManagementInterval Type0~150~15mA1010BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMLMTUP1Upper AlarmBSC6900SET BTSDGPSBP(Optional)If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "GPS", an alarm related to the GPS antenna is reported.MRFD-210304Faulty ManagementInterval Type45~15545~155mA100100BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMLMTUP2Upper AlarmBSC6900SET BTSDGPSBP(Optional)If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "RGPS", an alarm related to the RGPS antenna is reported.MRFD-210304Faulty ManagementInterval Type125~175125~175mA150150BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMOCACDURAlarm Occurrence Accumulate DurationBSC6900ADD BTSALMMGMRULE(Mandatory)Accumulated alarm occurrence duration.Threshold for the accumulated duration in which the alarm persists. If the accumulated duration exceeds this threshold, an alarm is generated. Otherwise, no alarm is generated.MRFD-210304Faulty ManagementInterval Type0~655350~65535sNoneNoneBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAlmOccurAccuTimeHThdAlarm Occur Accumulative Time ThresholdBSC6900SET BTSALMFLASHTHD(Optional)Alarm Occur Accumulative Time refers to the percentage of the alarm occurrence accumulative time to "Flash Statis Alarm Raise Time Window". If the alarm occurrence accumulative duration is greater than the parameter value, the BTS fault statistical alarm is reported. For example, if the parameter value is 60, it indicates that Alarm Occur Accumulative Time = "Flash Statis Alarm Raise Time Window" x 60%. If the parameter value is 0, no statistics is collected.MRFD-210304Faulty ManagementInterval Type0~1000~100per cent00BTSThe recommended value of this parameter is greater than twice "Alarm Clear Accumulative Time Threshold" and greater than twice "Flash Alarm Occur Threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAlmOccurAccuTimeLThdAlarm Clear Accumulative Time ThresholdBSC6900SET BTSALMFLASHTHD(Optional)Alarm Clear Accumulative Time refers to the percentage of the alarm clearance accumulative time to "Flash Statis Alarm Clear Time Window". If the alarm clearance accumulative duration is greater than this threshold, the BTS fault statistical alarm is cleared. For example, if the parameter value is 30, it indicates that Alarm Clear Accumulative Time = "Flash Statis Alarm Clear Time Window" x 30%. If the parameter value is 0, no statistics is collected.MRFD-210304Faulty ManagementInterval Type0~1000~100per cent00BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAlmOccurTimesHThdAlarm Occur Times ThresholdBSC6900SET BTSALMFLASHTHD(Optional)If the number of alarm flashes exceeds the value of this parameter within the time specified by "Flash Statis Alarm Raise Time Window", the BTS Statistical Alarm is generated. If this parameter is set to 0, the statistics of the BTS alarm flashes is not collected.MRFD-210304Faulty ManagementInterval Type0~2500~250None00BTSThe recommended value of this parameter is greater than twice "Alarm Clear Times Threshold".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentAlmOccurTimesLThdAlarm Clear Times ThresholdBSC6900SET BTSALMFLASHTHD(Optional)If the number of alarm flashes is smaller than the value of this parameter within the time specified by "Flash Statis Alarm Clear Time Window", the BTS Statistical Alarm is cleared. If this parameter is set to 0, the statistics of the BTS alarm flashes is not collected.MRFD-210304Faulty ManagementInterval Type0~2500~250None00BTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011EquipmentALMPARACFGFLAGAlarm Parameter Configuration EnabledBSC6900SET BTSDHEUBP(Optional)Whether the configuration of alarm parameters is allowed. The value "YES" indicates that the configuration is allowed, and the value "NO" indicates that the configuration is not allowed.MRFD-210304Faulty ManagementEnumeration TypeNO(NO), YES(YES)NO, YESNoneNONOBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALMTPAlarm TypeBSC6900EXP ALMLOG(Optional)STA ALMLOG(Optional)Type of the alarm. The alarm can be a fault alarm or an event alarm.MRFD-210304Faulty ManagementEnumeration Typeflt(Fault), evt(Event), all(All)flt, evt, allNoneallallBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALPHAALPHABSC6900SET GCELLPSPWPARA(Optional)It is used to perform open loop power control. Alpha parameter is used by the MS to calculate the output power PCH of the uplink PDCH. This parameter is used to set the reduced class of the Tx power of the MS, in correspondence with the path loss, when the GPRS dynamic power control is enabled.GBFD-119115Power ControlEnumeration Type0(0.0), 1(0.1), 2(0.2), 3(0.3), 4(0.4), 5(0.5), 6(0.6), 7(0.7), 8(0.8), 9(0.9), 10(1.0)0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10None66CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioALTIDECIAntenna Altitude Decimal PartBSC6900SET GCELLLCS(Optional)Decimal part of the antenna altitudeGBFD-115402BSS-Based LCS (Cell ID + TA)Interval Type0~90~0.9, step:0.1m00CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALTITUDEGPS antenna altitudeBSC6900ADD GPS(Mandatory)Height of the specified GSP receiver antennaNoneNoneInterval Type-1000~10000-1000~10000mNoneNoneBSC6900NoneRead & WriteNot involvedNot involvedNot involvedThe parameter cannot be modified.Not involvedNoneVersions earlier than BSC6900 V900R011EquipmentALTITUDEAntenna Altitude Int PartBSC6900SET GCELLLCS(Optional)Integer part of the antenna altitudeGBFD-115402BSS-Based LCS (Cell ID + TA)Interval Type0~65530~6553m4040CellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALTITUDEIMPGPS antenna altitudeBSC6900ADD GPS(Mandatory)Height of the specified GSP receiver antennaNoneNoneInterval Type-3281~32810-3281~32810feetNoneNoneBSC6900NoneRead & WriteNot involvedNot involvedNot involvedThe parameter cannot be modified.Not involvedNoneVersions earlier than BSC6900 V900R011EquipmentALVLAlarm SeverityBSC6900EXP ALMLOG(Optional)Alarm severity. One or more severities can be selected. By default, all severities are selected.MRFD-210304Faulty ManagementBit Field TypeCritical, Major, Minor, WarningCritical, Major, Minor, WarningNoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentALVLAlarm SeverityBSC6900SET ALMLVL(Mandatory)SET ALMSCRN(Mandatory)SET ENVALMPARA(Optional)Alarm severity. One or more severities can be selected. By default, all severities are selected.MRFD-210304Faulty ManagementEnumeration TypeCritical(Critical), Major(Major), Minor(Minor), Warning(Warning)Critical, Major, Minor, WarningNoneNoneNoneBSC6900NoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC0Feed Tri. 0 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 0GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC1Feed Tri. 1 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 1GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC2Feed Tri. 2 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 2GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC3Feed Tri. 3 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 3GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC4Feed Tri. 4 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 4GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMPC5Feed Tri. 5 TMA ConfigurationBSC6900SET BTSDATUBP(Optional)Whether to supply power to the TMA on tributary 5GBFD-111202O&M of BTSEnumeration TypeDISABLED(Disabled), ENABLED(Enabled)DISABLED, ENABLEDNoneDISABLEDDISABLEDBTSNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011EquipmentAMRBTSPWRNUMAMR BTS PC ClassBSC6900SET GCELLPWR2(Optional)Maximum degree by which the BSC can control the power of the AMR BTS dynamicallyGBFD-115503AMR Power ControlInterval Type1~162~32, step:2dB1616CellThis parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.If this parameter is set to a smaller value, the dynamic power adjustment range for the BTS is decreased. This may cause power waste and increase network interference when the downlink quality is good.Versions earlier than BSC6900 V900R011RadioAMRCALLPCALLOWEDAllow III Power Control For AMRBSC6900SET GCELLPWR3(Optional)Whether to enable the III power control algorithm for AMR calls. If enabled, power control is performed on AMR calls.GBFD-117601HUAWEI III Power Control AlgorithmEnumeration TypeOFF(Not Allowed), ON(Allowed)OFF, ONNoneONONCellThis parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneBSC6900 V900R011RadioAMRDADTHAWAMR Downlink Adaptive Threshold AllowedBSC6900SET GCELLCCAMR(Optional)Whether to enable the adaptive adjustment function of AMR downlink threshold. After this function is enabled, the BTS estimates the long-term voice quality (indicated by the long-term FER(frame erase ratio)) and compares the estimated result with the specified target voice quality. If the estimated result does not conform to the target voice quality, it indicates that the current AMR handover threshold may not be the best for the current radio conditions. In this case, the BSC6900 adjust threshold adaptively according to the relation between the estimated voice quality and the target voice quality.GBFD-115506AMR Coding Rate Threshold Adaptive AdjustmentEnumeration TypeNO(No), YES(Yes)NO, YESNoneNONOCellNoneRead & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.When this parameter is set to YES and the value of the downlink threshold is not reasonable, the algorithm can be used to dynamically adjust the AMR downlink rate to increase the downlink speech MOS.BSC6900 V900R011RadioAMRDLLEVFTLENAMR Filter Length for DL RX_LEVBSC6900SET GCELLPWR2(Optional)Number of measurement reports sampled for averaging downlink AMR signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment.GBFD-115503AMR Power ControlInterval Type1~20TCH:480~9600, step:480; SDCCH:470~9400, step:470ms55CellThis parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAMRDLPREDLENDAMR DL MR. Number PredictedBSC6900SET GCELLPWR2(Optional)Number of downlink AMR measurement reports that the BSC predicts. The BSC takes a while to confirm the power control effect of a power control command. Thus, the BSC makes a power control decision based on a measurement report that lags behind the changes in the receive level and quality instead of reflecting the real-time radio environment. As a result, the power control is late.To prevent late power control to a certain degree, the power control algorithm involves a measurement report prediction filter. The BSC can sample several downlink measurement reports in a short time and filter them according to a specific weight to predict future N measurement reports.This parameter specifies the number N.GBFD-115503AMR Power ControlInterval Type0~30~3None00CellThis parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAMRDLQHTHREDAMR DL Qual. Upper ThresholdBSC6900SET GCELLPWR2(Optional)Quality level threshold for decreasing downlink AMR signal power. If the BTS transmits AMR signals at a quality level less than "AMR DL Qual. Upper Threshold", the BSC decreases the power of the BTS. If (downlink receive level - "AMR MAX Down Adj. PC Value by Qual.") < "AMR DL RX_LEV Lower Threshold", the BSC does not adjust the transmit power.GBFD-115503AMR Power ControlInterval Type0~70~7None00CellThis parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLQLTHRED" >= "AMRDLQHTHRED".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.If this parameter is set to a smaller value, downlink power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a greater value, downlink power control may be performed when the voice quality is bad, thus affecting the voice quality.Versions earlier than BSC6900 V900R011RadioAMRDLQLTHREDAMR DL Qual. Lower ThresholdBSC6900SET GCELLPWR2(Optional)Quality level threshold for increasing downlink AMR signal power. If the BTS transmits AMR signals at a quality level greater than "AMR DL Qual. Lower Threshold", the BSC increases the power of the BTS. If (downlink receive level + "AMR MAX Up Adj. PC Value by Qual.") > "AMR DL RX_LEV Upper Threshold", the BSC does not adjust the transmit power.GBFD-115503AMR Power ControlInterval Type0~70~7None33CellThis parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLQLTHRED" >= "AMRDLQHTHRED".Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.If this parameter is set to a greater value, uplink power control may not be performed when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference.Versions earlier than BSC6900 V900R011RadioAMRDLQUAFTLENAMR Filter Length for DL Qual.BSC6900SET GCELLPWR2(Optional)Number of measurement reports sampled for averaging downlink AMR signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment.GBFD-115503AMR Power ControlInterval Type1~20TCH:480~9600, step:480; SDCCH:470~9400, step:470ms55CellThis parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAMRDLQUALBADTRIGAMR DL Qual Bad Trig ThresholdBSC6900SET GCELLPWR2(Optional)During downlink power control, if the downlink receive quality level is equal to or greater than this threshold, "AMR DL RX_LEV Upper Threshold" is increased by "AMR DL Qual Bad UpLEVDiff" to further increase the expected downlink power level.GBFD-115503AMR Power ControlInterval Type0~70~7None22CellThis parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2.Read & WriteN (No impact on the UE in idle mode)Not involvedNot involvedNoneThe parameter modification has no impact on the equipment.NoneVersions earlier than BSC6900 V900R011RadioAMRDLQUALBADUPLEVAMR DL Qual Bad UpLEVDiffBSC6900SET GCELLPWR2(Optional)During downlink power control, if the downlink receive q