hp virtual connect 3par direct attach config walkthrough

Upload: imadboy

Post on 18-Oct-2015

556 views

Category:

Documents


30 download

DESCRIPTION

3PAR

TRANSCRIPT

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    1/41

    HP Virtual Connect 3PARDirect Attach ConfigWalkthrough

    Hongjun Ma

    ISS Infrastructure Architect CCIE#6820

    [email protected]

    http://hongjunma.wordpress.com

    Version 1.2 9/24/2012

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    2/41

    2

    Disclaimer

    This presentation is created to help customers to understand more about HP Virtual

    product besides HP official documentations and white papers.

    The presentation is solely my personal view and NOT an official HP reviewed/certified

    Connect doc and best practice white paper. For final answers on Virtual Connect and 3

    features and best practice, please consult with your local HP account team and partn

    check official HP documentations.

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    3/41

    3

    Revision History

    Version Date Description

    1.0 9/16/2012 Initial version

    1.1 9/21/2012 Small modifications based on feedbacks

    1.2 9/24/2012 Small modifications, add disclaimer page

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    4/41

    4

    Virtual Connect Direct Attach to 3PAR Stor VC FlexFabric module can directly attach 3PAR storage without SAN switches to save

    management cost.

    FlexFabric module implements simplified SAN fabric services like automatic zoning a

    services. You can still connect FlexFabric uplinks to SAN switch for traditional SAN fabric servic

    exist with the new direct attach connection.

    Requirements:

    The feature is only available for VC FlexFabric module with VC3.70 and later.

    It only supports HP 3PAR(V,T and F-series) storage with Inform OS 3.1.1 MU1 and late

    Other storage arrays support may be planned in the future

    Recommended Links For Virtual Connect Direct Attach Implementation:

    Virtual Connect Fibre Channel Cookbook

    Virtual Connect 3.70 User Guide

    3PAR VMware Implementation Guide

    3PAR vSphere 5 Best Practice

    http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01702940/c01702940.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03478464/c03478464.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03290624/c03290624.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03290624/c03290624.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03478464/c03478464.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01702940/c01702940.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01702940/c01702940.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01702940/c01702940.pdfhttp://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c01702940/c01702940.pdf
  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    5/41

    5

    Virtual Connect Fibre Channel Connectivity Su

    Option 1: Fabric Attach

    Option 2: Direct Attach

    Before 3.70: Option 1

    After 3.70: Option 1 OROption 2 OROption1+Option2

    3PAR V800 supports up to 192 FC host ports. This means

    can be connected to a single 3PAR when using 4 FC uplink

    With 8:1

    oversubscription

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    6/41

    6

    Direct Attach Fabric Demo Topology

    Controller

    Node 0

    Controller

    Node 1

    0 1 2

    1

    2

    3

    4

    1

    2

    3

    4

    0 1 2

    Port 0/2/2 PWWN

    20220002AC00159E

    Port 0/2/3 PWWN

    20230002AC00159E

    Port 1/2/2 PWWN

    21220002AC00159E

    Port 1/2/3 PWWN

    21230002AC00159E

    3PAR V400 NW

    2FF70002AC001

    Blade 3(ESXi5.0)vmhba1 pwwn

    50060B0000C26600

    Fabric A Fabric B

    FCOEvmhba2 pwwn

    50060B0000C26602

    FCOE

    IO Bay 1

    X1 X2 X1 X2

    d3 d3

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    7/41

    7

    Quick Notes

    Cabling Best Practice:

    Each controller node should be connected to both fabrics

    Ports of the same pair of nodes with the same ID shouldbe connected to the same fabric. Example :

    0:2:1 and 1:2:1 on Fabric 1

    0:2:2 and 1:2:2 on Fabric 2

    3PAR WWN Identification

    Better Cabling Following B

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    8/41

    8

    Virtual Connect Direct Attach Fabric Conf

    Fabric A

    Fabric B

    3PAR port1/2/3

    3PAR port0/2/2

    3PAR port1/2/2

    3PAR port0/2/3

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    9/41

    9

    Virtual Connect Server Profile Config

    vmhba1

    vmhba2

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    10/41

    10

    Direct Attach Fabric Connection Status

    VC port pwwn, not used for zoning To 3PAR port 0/2/2

    To 3PAR port 0/2/3 aVC port pwwn, not used for zoning

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    11/41

    11

    Virtual Connect Fabric Name Server

    To 3PARTo blade3 vmhba1

    To 3PAR poTo blade3 vmhba2

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    12/41

    12

    Direct Attach Fabric Auto-Configured Zon

    Fabric A Fabric B

    vmhba1

    3par 0/2/2

    vmhba1

    3par 1/2/3

    vmhba2

    3par 0/2/3

    vmhba2

    3par 1/2/2

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    13/41

    13

    3PAR Configuration Task Flow

    Config Fabric-

    facing Ports

    Create Host

    Create CPGCreate Virtual

    Volume

    Expor

    Volum

    * Common Provision Group(CPG)

    * Define Disk Type/RAID

    * Define Volume Size

    * Thin/Thick Provisioning

    The flow here is to help users new to 3PAR to get a quick start

    For 3PAR documentations like VMware Implentation guide and 3PAR Concepts Guide, please check 3PA

    http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?lang=en&cc=us&contentType=SupportManual&prodTypeId=18964&prodSeriesId=5044394&docIndexId=64255http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?lang=en&cc=us&contentType=SupportManual&prodTypeId=18964&prodSeriesId=5044394&docIndexId=64255
  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    14/41

    14

    Config 3PAR FC Ports to Connect with VC Fa

    Right Click the port and choose Configure

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    15/41

    15

    Config 3PAR FC Ports to Connect with VC Fa

    Change Mode to Host

    and Type to Point

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    16/41

    16

    Config Host: Create Host

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    17/41

    17

    Config Host: Define Persona

    For VMware host, choose 6 instead of default 1 for Persona.

    Please see 3PAR VMware Implementation Guideand 3PAR vSphere 5 Best Practice

    So

    recom

    http://h20000.www2.hp.com/bizsupport/TechSupport/CoreRedirect.jsp?redirectReason=DocIndexPDF&prodSeriesId=5044394&targetPage=http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03290624/c03290624.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://h20195.www2.hp.com/V2/GetPDF.aspx/4AA4-3286ENW.pdfhttp://h20000.www2.hp.com/bizsupport/TechSupport/CoreRedirect.jsp?redirectReason=DocIndexPDF&prodSeriesId=5044394&targetPage=http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03290624/c03290624.pdfhttp://h20000.www2.hp.com/bizsupport/TechSupport/CoreRedirect.jsp?redirectReason=DocIndexPDF&prodSeriesId=5044394&targetPage=http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03290624/c03290624.pdf
  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    18/41

    18

    Config Host: Define Host PWWN

    If you have pre-defined PWWN like VC-assigned

    value, you can cut/paste here.

    Note: Pure digits only, otherwise cant be pasted in

    If you have

    host WWN

    After cut/paste

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    19/41

    19

    Config CPG: Create Common Provison Gro

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    20/41

    20

    Config CPG: Define Disk and RAID Type

    Device Type can be:

    SSD

    FC SAS

    NL(Near Line) SATA

    for different storage performance tiers

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    21/41

    21

    Define RAID type

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    22/41

    22

    Config CPG: Verify the CPG Created

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    23/41

    23

    Create Virtual Volume: Create from CPG

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    24/41

    24

    Create Virtual Volume: Choose Full or Thin Pro

    Choose Fully/Thinly Provision

    Do NOT use Fully Provisioned from

    Physical Disk even though you can

    do it, its against 3PAR Best Practice

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    25/41

    25

    Create Virtual Volume: Define Which CPG to B

    If choose touse CPG, the list of CPGs

    available

    Export Virtual Volume to Host

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    26/41

    26

    Export Virtual Volume to Host

    Right Click the v

    volume just crea

    choose Export

    i

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    27/41

    27

    Export Virtual Volume to Host

    E Vi l V l H Ch H

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    28/41

    28

    Export Virtual Volume to Host: Choose Ho

    Choose the host defined in

    the previous steps

    Optionally choose which

    local FC port the volume

    can be exported. Leave

    none for all possible path

    from this host

    E Vi l V l H D fi LUN N

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    29/41

    29

    Export Virtual Volume to Host: Define LUN Nu

    Define LUN Number

    E t Vi t l V l t H t

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    30/41

    30

    Export Virtual Volume to Host

    If host has not logged in yet,

    youll get this warning. Click

    Yes to continue. VLUN will be

    created after host logs in

    3PAR Sh h t

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    31/41

    31

    3PAR Showhost

    After host pwwn logs in,

    VLUN is created at the

    specified paths.

    3PAR Sh h t

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    32/41

    32

    3PAR Showhost

    2 host HBA pwwn seen

    Logged in through 4

    local FC ports

    Host vmhba1

    Host vmhba2

    Log in thr

    Log in thr

    Remember to use Pers

    3PAR Showport

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    33/41

    33

    3PAR Showport

    VMware HBA Status

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    34/41

    34

    VMware HBA Status

    VC-assigned P

    3par port 1/2/3 an

    through Virtual Co

    VMware HBA Status

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    35/41

    35

    VMware HBA Status

    VC-assigned PWWN

    3par port 1/2/2 an

    through Virtual Co

    VMware Host Path Status

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    36/41

    36

    VMware Host Path Status

    3par port 0/2/2, 0/2/3, 1/2/2 and 1/2/3

    through VC Fabric A and B

    Multipath Load Monitoring: VMware

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    37/41

    37

    p g

    Multipath Load Monitoring: VC SNMP

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    38/41

    38

    p g

    First Uplink

    on the module

    Multipath Load Monitoring: VC Manager Port

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    39/41

    39

    p g g

    Interface TX/RX rate

    Multipath Load Monitoring---3PAR Performance Mo

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    40/41

    40

    Create chart using

    system monitor

  • 7/14/2019 Hp Virtual Connect 3par Direct Attach Config Walkthrough

    41/41

    Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

    Thank you