how to use the system reference guide · how to use the system reference guide the system reference...
TRANSCRIPT
![Page 1: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/1.jpg)
HOW TO USE THE SYSTEM REFERENCE GUIDE
The System Reference Guide was designed to be a simple to use, comprehensiveresource which will aid dealers in putting together and selling systems.
The following step-by-step instructions should facilitate your successful use of thisguide.
Instructions:
Step 1: Determine if you need an air conditioning, heat pump, or furnace system.Flip to the appropriate section (indicated by tabs).
Step 2: Determine what size (tonnage) or efficiency (AFUE) unit is required for yoursystem. Flip to the appropriate section (again, indicated by tabs).
Step 3: For Air Conditioning and Heat Pumps:
• Choose outdoor condensing unit based on desired efficiency and price level.
• Choose indoor unit based on efficiency and capacity needs, as well aswhether a fan or furnace coil is desired.
• Note: Refer to Furnace tab to aid selection of coil. • Work from left to right through the flow chart picking any options or option
packages desired. • Use Master Price Page (separate document) to fill in price line at bottom of
sheet. • Add up total system price.
For Gas Furnaces:
• Flip to furnace tab. • Scan the left hand column to find desired AFUE, in descending order. • Bold type headings are provided to aid selection by
- Upflow, Downflow, Horizontal- Model and Trade Name- Distinguishing Features
• Work from left to right through the flow chart picking any options desired. • Use Master Price Page (separate document) to fill in price line at bottom
of sheet. • Add up total system price.
Select this Icon in the Tool Bar to open index
![Page 2: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/2.jpg)
SYSTEM OPTIONS - DESCRIPTION AND USAGE
1. Time Delay Relay (TDR) - A SPST delay relay which briefly continues operation of the indoor blower motor to provide additionalcooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoorand outdoor units.
2. Thermostatic Expansion Valve (TXV) Kit - A modulating flow-control valve which meters refrigerant liquid flow rate into theevaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes andexternal equalizer tube. SUGGESTED USE: For improved system performance in cooling mode for certain combinations ofindoor and outdoor units.
3. Liquid Line Solenoid Valve (LLS) - An electrically operated shut-off valve to be installed at the outdoor or indoor unit(depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. SUGGESTED USE: For improvedsystem performance in air conditioners for certain combinations of indoor and outdoor units. In certain long line applications(Refer to Long-Line Application Guideline).
4. Crankcase Heater - An electric resistance heater which mounts to the base of the reciprocating compressor to keep thelubricant warm during off cycles. Improves reciprocating compressor lubrication on restart and minimizes chance of refrigerantslugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 feet. When unit will be operated below 55°F (12.8°C) outdoor temperature. All commercial installations.
5. Refrigerant F ilter Drier - A device for removing contaminants from refrigerant circulating in an air conditioner; 1 direction flow forair conditioners, bi-directional for heat pumps. SUGGESTED USE: All field connected split-system air conditioners.
6. Compressor Start Assist·PTC Type (Start Assist - PTC) - Solid state electrical device which gives a "soft" boost to thereciprocating Compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil. Replacement installations with undersizedinterconnecting refrigerant tubes.
7. Compressor Start Assist·Capacitor/Relay Type (Start Capacitor) - Start capacitor and start relay gives "hard" boost toreciprocating compressor motor at each start·up. SUGGESTED USE: Installations where interconnecting tube length exceeds50 feet. Installations where outdoor design temperature exceeds 105°F (40.6°C). Replacement installations with hard shut-offexpansion valve on indoor coil.
8. Cycle Protector - Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to "play" with the roomthermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 feet. High rise applications.
9. Low-Ambient Controller - This solid-state head pressure controller is a fan speed control device activated by a temperaturesensor. It is specifically designed to control outdoor fan motor speed in response to saturated condensing temperature. Foroutdoor air temperatures between 55° and 0°F (12.8° and - 17.8°C), it maintains condensing temperature at 100°F +/-5°C). SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C). All commercial installations.
10. Winter Start Control - A SPST delay relay which bypasses the low pressure switch for approximately 3 minutes to permit startup for cooling operation under low load conditions. SUGGESTED USE: All air conditioners where low-ambient controller hasbeen added.
11. Evaporator Freeze Thermostat - A SPST temperature actuated switch which stops unit operation when evaporator reachesfreeze-up conditions. SUGGESTED USE: All units where low-ambient controller has been added.
12. Isolation Relay - A SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heatpump switches to heating mode. SUGGESTED USE: All heat pumps where low-ambient controller has been added.
13. Interface Control - An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. Itallows heat pump to operate down to a pre-determined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat adjusted for economic balance point temperature. SUGGESTED USE: All heat pump and gas- or oil-fired furnace combination systems.
14. Outdoor Thermostat - A SPDT temperature actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations with single-stage supplemental heaters smallerthan 30kw.
15. Secondary Outdoor Thermostat - A SPDT temperature actuated switch which turns on second-stage of supplemental electricheaters when outdoor air temperature drops below the second-stage set point. SUGGESTED USE: Heat pump installationswhere 2-stage operation of supplemental heaters is desired.
16. Support Feet - Two rigid plastic risers which raise the unit 6 inches above the mounting pad. This allows sand, dirt and otherdebris to be flushed from the unit base and minimizes corrosion. SUGGESTED USE: Coastal installations. Windy areas orwhere debris is normally circulating. Rooftop installations.
17. Sound Blan ket/Shield/Hood - Wrap around sound attenuation cover for the compressor. Reduces the sound level by about 0.2bels. SUGGESTED USE: Unit installed closer than 15 feet to quiet areas -- bedrooms, etc. Unit installed between 2 houses lessthan 10 feet apart.
18. Refrigerant Low-Pressure Switch - Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressorrecycling. Compressor short cycle protector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to"dirty" air. All commercial installations. (Note: Standard on 3-phase units)
19. Refrigerant High-Pressure Switch - Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 psig. Provides additional protection against compressor damagedue to loss of outdoor airflow. To prevent rapid compressor recycling. SUGGESTED USE: Installations exposed to very "dirty"outdoor air. Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
20. Snow Rack - Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage form unit base. SUGGESTEDUSE: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations inareas of prolonged sub-freezing temperatures. All commercial installations.
21. Whips - U.L. approved electrical connection - O.D. disconnect to unit. SUGGESTED USE: Ease of installation on any.
![Page 3: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/3.jpg)
SYSTEM OPTIONS - DESCRIPTIONS AND USAGE
1. Thermostatic Expansion Valve (TXV) Kit - A modulating flow-control valve which meters refrigerant liquidflow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kitincludes valve, adapter tubes, and external equalizer tube. SUGGESTED USE: For improved systemperformance in cooling mode for certain combinations of indoor and outdoor units.
2. Crankcase Heater - An electric resistance heater which mounts to the base of the reciprocatingcompressor to keep the lubricant warm during off cycles. Improves reciprocating compressor lubrication onrestart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below55°F (12.8°C) outdoor temperature. All commercial installations.
3. Refrigerant Filter Drier - A device for removing contaminants from refrigerant circulating in an airconditioner; 1 direction flow for air conditioners, bi-directional for heat pumps. SUGGESTED USE: All field-connected split-system air conditioners.
4. Compressor Start Assist·Capacitor/Relay Type (Start Capacitor) - Start capacitor and start relay gives"hard" boost to reciprocating compressor motor at each start·up. SUGGESTED USE: Installations whereinterconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105°F(40.6°C). Replacement installations with hard shut-off expansion valve on indoor coil.
5. Outdoor Thermostat - A SPDT temperature actuated switch which turns on supplemental electric heaterswhen outdoor air temperature drops below set point. SUGGESTED USE: Heat pump installations withsingle-stage supplemental heaters smaller than 30 kw.
6. Secondary Outdoor Thermostat - A SPDT temperature actuated switch which turns on second-stage ofsupplemental electric heaters when outdoor air temperature drops below the second-stage set point.SUGGESTED USE: Heat pump installations where 2-stage operation of supplemental heaters is desired.
7. Support Feet - Two rigid plastic risers which raise the unit 6 in. above the mounting pad. This allowssand, dirt, and other debris to be flushed from the unit base and minimizes corrosion. SUGGESTED USE:Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations.
8. Sound Blanket/Shield/Hood - Wrap around sound attenuation cover for the compressor. Reduces thesound level by about 0.2 bels. SUGGESTED USE: Unit installed closer than 15 ft to quiet areas --bedrooms, etc. Unit installed between 2 houses less than 10 ft apart.
9. Refrigerant Low-Pressure Switch - Auto reset SPST switch activated by refrigerant pressure on low sideof refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoorcoil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressordamage due to loss of refrigerant charge. To prevent rapid compressor recycling. Compressor short cycleprotector can be used with this switch. SUGGESTED USE: Where indoor coil is exposed to "dirty" air. Allcommercial installations. (Note: Standard on 3-phase units)
10. Refrigerant High-Pressure Switch - Auto reset SPST switch activated by refrigerant pressure on highside of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400 psig. Providesadditional protection against compressor damage due to loss of outdoor airflow. To prevent rapidcompressor recycling, SUGGESTED USE: Installations exposed to very "dirty" outdoor air. Installationswhere condenser inlet air temperature exceeds 125°F (51.7°C).
11. "B" Furnace Interface Kit - Allows 2-speed outdoor units to select high and low airflow when used with2-speed gas furnaces. It is required when matching a 2-speed unit with a "B" furnace.
![Page 4: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/4.jpg)
38BRB02430 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 23.20 FA4ANF024000
12.00 12.00 23.60 FA4ANF030000
12.00 12.00 23.20 FB4ANF024000
12.00 12.00 23.60 FB4ANF030000
12.00 23.20 FC4BNF024000
12.00 23.60 FC4BNF030000
12.00 24.00 FC4BNF033000
12.00 23.20 FD3ANA024000
12.00 23.80 FD3ANA030000
12.00 12.00 23.20 FF1ANA024000
12.00 12.00 23.40 FF1ANA030000
12.00 12.00 23.20 FF1BNA024000
12.00 12.00 23.40 FF1BNA030000
12.00 23.00 FG3AAA024000
13.50 23.80 FK4BNF002000
14.00 23.80 FK4BNF003000
14.00 23.80 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass4
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1801COP
Support FeetN/A
TXV (RPB)KAATX0301RPB
Vinyl CoverP166-0006
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 23.20 CC5AXA024000
12.10 23.40 CC5AXA030000
13.00 24.00 CC5AXA042000
12.00 23.20 CC5AXW024000
12.10 23.40 CC5AXW030000
12.00 23.20 CD5AXA024000
12.10 23.40 CD5AXA030000
13.00 24.00 CD5AXA042000
12.00 23.20 CD5AXW024000
12.10 23.40 CD5AXW030000
12.00 23.20 CD5BXA024000
12.10 23.40 CD5BXA030000
13.00 24.00 CD5BXA042000
12.00 23.20 CD5BXW024000
12.10 23.40 CD5BXW030000
12.00 23.40 CF5AXA024000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 23.20 CD3AXA024000
12.10 23.40 CD3AXA030000
12.00 23.20 CD3BXA024000
12.10 23.40 CD3BXA030000
12.00 23.60 CD3CXA024000
12.00 23.60 CD3CXA030000
12.00 23.40 CE3AXA024000
12.10 23.60 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 5: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/5.jpg)
38BRB03030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.10 12.10 29.20 FA4ANF030000
12.00 12.00 29.60 FA4ANF036000
12.10 12.10 29.20 FB4ANF030000
12.00 12.00 29.60 FB4ANF036000
12.10 29.20 FC4BNF030000
12.50 30.00 FC4BNF033000
12.00 29.60 FC4BNF036000
12.00 29.60 FD3ANA030000
12.00 12.00 29.00 FF1ANA030000
12.00 12.00 29.00 FF1BNA030000
12.50 29.60 FG3AAA036000
13.00 29.40 FK4BNF001000
13.50 29.40 FK4BNF002000
14.00 29.80 FK4BNF003000
14.00 29.80 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-ZoneController Cover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1801COP
Support FeetN/A
TXV (RPB)KAATX0401RPB
Vinyl CoverP166-0007
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 29.00 CC5AXA030000
12.00 29.60 CC5AXA036000
12.00 29.00 CC5AXW030000
12.00 29.00 CD5AXA030000
12.00 29.60 CD5AXA036000
13.00 30.00 CD5AXA048000
12.00 29.00 CD5AXW030000
12.00 29.60 CD5AXW036000
12.00 29.00 CD5BXA030000
12.00 29.60 CD5BXA036000
13.00 30.00 CD5BXA048000
12.00 29.00 CD5BXW030000
12.00 29.60 CD5BXW036000
12.00 29.60 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 29.00 CD3AXA030000
12.00 29.60 CD3AXA036000
12.00 29.00 CD3BXA030000
12.00 29.60 CD3BXA036000
12.00 29.20 CD3CXA030000
12.20 29.60 CD3CXA036000
12.00 29.00 CE3AXA030000
12.00 29.60 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 6: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/6.jpg)
38BRB03630 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.10 12.10 35.00 FA4ANB042000
11.50 11.50 35.00 FA4ANF036000
12.10 12.10 35.00 FA4ANF042000
12.10 12.10 35.00 FB4ANB042000
11.50 11.50 35.00 FB4ANF036000
12.10 12.10 35.00 FB4ANF042000
12.10 35.00 FC4BNB042000
13.00 36.00 FC4BNB054000
12.00 35.00 FC4BNF033000
11.50 35.00 FC4BNF036000
12.50 36.00 FC4BNF038000
12.10 35.00 FC4BNF042000
12.00 34.60 FG3AAA036000
13.50 36.00 FK4BNB005000
14.00 36.00 FK4BNB006000
12.00 34.80 FK4BNF001000
12.00 34.80 FK4BNF002000
13.00 35.00 FK4BNF003000
13.00 35.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-ZoneController Cover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH0601COP
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0007
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 35.00 CC5AXA036000
12.00 35.00 CC5AXA042000
12.00 35.00 CC5AXW042000
12.00 35.00 CD5AXA036000
12.00 35.00 CD5AXA042000
12.00 35.00 CD5AXW036000
12.00 35.00 CD5AXW042000
12.00 35.00 CD5BXA036000
12.00 35.00 CD5BXA042000
12.00 35.00 CD5BXW036000
12.00 35.00 CD5BXW042000
12.00 35.00 CF5AXA036000
12.00 35.00 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗,58MXA∗,
58PAV∗, 58TUA∗,58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 35.00 CD3AXA036000
12.00 35.00 CD3AXA042000
12.00 35.00 CD3BXA036000
12.00 35.00 CD3BXA042000
12.00 34.00 CD3CXA036000
12.00 34.00 CD3CXA042000
12.00 35.00 CE3AXA036000
12.10 35.00 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 7: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/7.jpg)
38BRB04230 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.50 11.50 40.00 FA4ANB042000
12.00 12.00 40.50 FA4ANB048000
11.50 11.50 40.00 FA4ANF042000
12.00 12.00 40.50 FA4ANF048000
11.50 11.50 40.00 FB4ANB042000
12.00 12.00 40.50 FB4ANB048000
11.50 11.50 40.00 FB4ANF042000
12.00 12.00 40.50 FB4ANF048000
11.50 40.00 FC4BNB042000
12.00 40.50 FC4BNB048000
12.50 42.00 FC4BNB054000
12.00 41.00 FC4BNF038000
11.50 40.00 FC4BNF042000
12.00 40.50 FC4BNF048000
12.00 40.50 FG3AAA048000
13.00 41.50 FK4BNB005000
14.00 42.00 FK4BNB006000
12.50 41.00 FK4BNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-ZoneController Cover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH0601COP
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0008
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 40.00 CC5AXA042000
12.00 40.00 CC5AXC048000
12.00 40.00 CC5AXW042000
12.00 40.50 CC5AXW048000
12.00 40.00 CD5AXA042000
12.00 40.50 CD5AXA048000
12.00 40.00 CD5AXC048000
12.00 40.00 CD5AXW042000
12.00 40.50 CD5AXW048000
12.00 40.00 CD5BXA042000
12.00 40.50 CD5BXA048000
12.00 40.00 CD5BXC048000
12.00 40.00 CD5BXW042000
12.00 40.50 CD5BXW048000
12.00 40.50 CF5AXA048000
12.00 40.50 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 40.00 CD3AXA042000
12.00 40.50 CD3AXA048000
12.00 40.00 CD3BXA042000
12.00 40.50 CD3BXA048000
11.50 39.00 CD3CXA042000
12.00 40.00 CD3CXA048000
12.00 40.00 CE3AXA042000
12.00 40.50 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 8: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/8.jpg)
38BRB04830 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 47.00 FA4ANB048000
12.10 12.10 47.50 FA4ANB060000
12.00 12.00 47.00 FA4ANF048000
12.10 12.10 47.50 FA4ANF060000
12.00 12.00 47.00 FB4ANB048000
12.10 12.10 47.50 FB4ANB060000
12.00 12.00 47.00 FB4ANF048000
12.10 12.10 47.50 FB4ANF060000
12.00 47.00 FC4BNB048000
12.50 48.00 FC4BNB054000
12.10 47.50 FC4BNB060000
12.00 47.00 FC4BNF048000
12.10 47.50 FC4BNF060000
12.00 47.00 FG3AAA048000
12.20 48.00 FG3AAA060000
13.50 48.00 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2101COP
Support FeetN/A
TXV (RPB)KAATX0601RPB
Vinyl CoverP166-0007
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.10 47.50 CC5AXA060000
12.00 46.00 CC5AXC048000
12.00 47.00 CC5AXW048000
12.20 47.50 CC5AXW060000
12.00 47.00 CD5AXA048000
12.10 47.50 CD5AXA060000
12.00 46.00 CD5AXC048000
12.00 47.00 CD5AXW048000
12.20 47.50 CD5AXW060000
12.00 47.00 CD5BXA048000
12.10 47.50 CD5BXA060000
12.00 46.00 CD5BXC048000
12.00 47.00 CD5BXW048000
12.20 47.50 CD5BXW060000
12.00 47.00 CF5AXA048000
12.00 47.00 CG5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 47.00 CD3AXA048000
12.10 47.50 CD3AXA060000
12.00 47.00 CD3BXA048000
12.10 47.50 CD3BXA060000
11.80 46.00 CD3CXA048000
12.00 48.50 CD3CXA060000
12.00 47.00 CE3AXA048000
12.10 47.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 9: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/9.jpg)
38BRB06030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.50 11.50 58.00 FA4ANB060000
11.50 11.50 58.00 FA4ANF060000
11.50 11.50 58.00 FB4ANB060000
12.00 12.00 58.50 FB4ANB070000
11.50 11.50 58.00 FB4ANF060000
12.20 58.00 FC4BNB054000
11.50 58.00 FC4BNB060000
12.00 58.50 FC4BNB070000
11.50 58.00 FC4BNF060000
11.50 57.50 FG3AAA060000
12.50 59.00 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2101COP
Support FeetN/A
TXV (RPB)KAATX0701RPB
Vinyl CoverP166-0008
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 56.00 CC5AXA060000
12.00 58.00 CC5AXW060000
11.50 56.00 CD5AXA060000
12.00 58.00 CD5AXW060000
11.50 56.00 CD5BXA060000
12.00 58.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58SXC∗,58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.50 56.00 CD3AXA060000
11.50 56.00 CD3BXA060000
11.50 57.00 CD3CXA060000
12.00 58.00 CD3CXA070000
12.00 58.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 10: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/10.jpg)
38CKB01831 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.00 16.80 FA4ANF018000
10.50 10.50 17.60 FA4ANF024000
10.00 10.00 16.80 FB4ANF018000
10.50 10.50 17.60 FB4ANF024000
10.50 17.60 FC4BNF024000
10.50 17.60 FC4BNF033000
10.00 17.10 FD3ANA018000
10.50 17.60 FD3ANA024000
10.50 10.50 17.20 FF1ANA018000
10.50 10.50 17.60 FF1ANA024000
10.50 10.50 17.20 FF1BNA018000
10.50 10.50 17.60 FF1BNA024000
10.00 10.20 17.50 FG3AAA024000
12.00 17.50 FK4BNF001000
12.00 17.50 FK4BNF002000
12.00 17.50 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Air cleaner sized based on system airflow.3. Humidifier sized based on relative humidity needs.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass4
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX0901HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketN/A
Support FeetN/A
TXV (RPB)KAATX0201RPB
Vinyl CoverP166-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 17.20 CC5AXA018000
10.00 10.50 17.60 CC5AXA024000
10.00 10.50 17.60 CC5AXW024000
10.00 17.20 CD5AXA018000
10.00 10.50 17.60 CD5AXA024000
10.00 10.50 17.60 CD5AXW024000
10.00 17.20 CD5BXA018000
10.00 10.50 17.60 CD5BXA024000
10.00 10.50 17.60 CD5BXW024000
10.00 10.50 17.80 CF5AXA024000
10.00 10.50 17.80 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 17.00 CD3AXA018000
10.00 10.50 17.60 CD3AXA024000
10.20 17.00 CD3BXA018000
10.00 10.50 17.60 CD3BXA024000
10.00 10.50 17.80 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER3
AIRTREATMENT2 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 11: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/11.jpg)
38CKB02430 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.00 22.60 FA4ANF024000
10.20 10.20 23.00 FA4ANF030000
10.00 10.00 22.60 FB4ANF024000
10.20 10.20 23.00 FB4ANF030000
10.20 22.40 FC4BNF024000
10.50 22.80 FC4BNF030000
10.50 23.40 FC4BNF033000
10.20 22.20 FD3ANA024000
10.20 23.00 FD3ANA030000
10.00 10.00 22.60 FF1ANA024000
10.00 10.00 23.20 FF1ANA030000
10.00 10.00 22.60 FF1BNA024000
10.00 10.00 23.20 FF1BNA030000
10.00 22.00 FG3AAA024000
12.00 24.80 FK4BNB005000
11.50 23.60 FK4BNF001000
11.50 23.80 FK4BNF002000
11.50 23.60 FK4BNF003000
11.50 24.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. Size dependent on home duct size.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass6
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
6
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers6
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketN/A
Support FeetN/A
TXV (RPB)KAATX0301RPB
Vinyl CoverP166-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 22.00 CB5AXA030000
10.00 22.40 CC5AXA024000
10.00 22.60 CC5AXA030000
10.00 22.40 CC5AXW024000
10.00 22.60 CC5AXW030000
10.00 22.40 CD5AXA024000
10.00 22.60 CD5AXA030000
10.00 22.40 CD5AXW024000
10.00 22.60 CD5AXW030000
10.00 22.40 CD5BXA024000
10.00 22.60 CD5BXA030000
10.00 22.40 CD5BXW024000
10.00 22.60 CD5BXW030000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 22.40 CD3AXA024000
10.00 22.60 CD3AXA030000
10.00 22.40 CD3BXA024000
10.00 22.60 CD3BXA030000
10.00 22.60 CD3CXA024000
10.00 22.60 CE3AXA024000
10.00 23.00 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 12: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/12.jpg)
38CKB03030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.10 27.60 FA4ANF030000
10.00 10.00 28.20 FA4ANF036000
10.00 10.10 27.60 FB4ANF030000
10.00 10.00 28.20 FB4ANF036000
10.00 27.60 FC4BNF030000
10.10 29.00 FC4BNF033000
10.00 28.20 FC4BNF036000
10.00 27.80 FD3ANA030000
10.00 10.00 28.00 FF1ANA030000
10.00 10.00 28.00 FF1BNA030000
10.00 10.10 28.00 FG3AAA036000
10.50 29.00 FK4BNF001000
10.50 29.00 FK4BNF002000
11.00 29.00 FK4BNF003000
11.00 29.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1301TEC
Support FeetN/A
TXV (RPB)KAATX0401RPB
Vinyl CoverP166-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.10 27.60 CB5AXA030000
10.00 10.10 28.80 CB5AXW036000
10.00 10.10 28.00 CC5AXA030000
10.00 10.10 29.00 CC5AXA036000
10.00 10.10 28.00 CC5AXW030000
10.00 10.10 28.00 CD5AXA030000
10.00 10.10 29.00 CD5AXA036000
10.00 10.10 28.00 CD5AXW030000
10.00 10.10 29.00 CD5AXW036000
10.00 10.10 28.00 CD5BXA030000
10.00 10.10 29.00 CD5BXA036000
10.00 10.10 28.00 CD5BXW030000
10.00 10.10 29.00 CD5BXW036000
10.00 10.10 28.80 CF5AXA036000
10.00 10.10 28.80 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.10 28.00 CD3AXA030000
10.00 10.10 29.00 CD3AXA036000
10.00 10.10 28.00 CD3BXA030000
10.00 10.10 29.00 CD3BXA036000
10.00 10.10 27.80 CD3CXA030000
10.00 10.10 27.80 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 13: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/13.jpg)
38CKB03630 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS
10.00 10.00 34.00 FA4ANB042000
10.00 10.00 33.20 FA4ANF036000
10.00 10.00 34.00 FA4ANF042000
10.00 10.00 34.00 FB4ANA042000
10.00 10.00 34.00 FB4ANB042000
10.00 10.00 33.20 FB4ANF036000
10.00 10.00 34.00 FB4ANF042000
10.00 10.00 34.00 FB4ANM042000
10.00 34.20 FC4BNB042000
10.50 35.00 FC4BNB054000
10.00 34.20 FC4BNF033000
10.00 33.60 FC4BNF036000
10.00 35.00 FC4BNF038000
10.00 34.20 FC4BNF042000
10.00 33.20 FG3AAA036000
11.00 35.00 FK4BNB005000
11.50 33.50 FK4BNB006000
10.50 34.00 FK4BNF001000
10.50 34.00 FK4BNF002000
11.00 34.40 FK4BNF003000
10.50 34.60 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1901CYL
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0002
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow
10.00 10.20 33.80 CB5AXW036000
10.00 10.20 34.00 CC5AXA036000
10.00 10.20 34.00 CC5AXA042000
10.00 10.20 33.60 CC5AXW042000
10.00 10.20 34.00 CD5AXA036000
10.00 10.20 34.00 CD5AXA042000
10.00 10.20 34.00 CD5AXW036000
10.00 10.20 33.60 CD5AXW042000
10.00 10.20 34.00 CD5BXA036000
10.00 10.20 34.00 CD5BXA042000
10.00 10.20 34.00 CD5BXW036000
10.00 10.20 33.60 CD5BXW042000
10.00 10.20 33.80 CF5AXA036000
10.00 10.20 33.60 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal
10.00 10.20 34.00 CD3AXA036000
10.00 10.20 34.00 CD3AXA042000
10.00 10.20 34.00 CD3BXA036000
10.00 10.20 34.00 CD3BXA042000
10.00 32.40 CD3CXA036000
10.20 33.60 CE3AXA036000
10.00 10.20 34.20 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 14: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/14.jpg)
38CKB04230 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS
10.00 10.00 40.00 FA4ANB04200010.10 10.10 41.00 FA4ANB04800010.00 10.00 40.00 FA4ANF04200010.10 10.10 41.00 FA4ANF04800010.00 10.00 40.00 FB4ANB04200010.10 10.10 41.00 FB4ANB04800010.00 10.00 40.00 FB4ANF04200010.10 10.10 41.00 FB4ANF04800010.00 40.00 FC4BNB04200010.10 41.00 FC4BNB04800010.50 41.50 FC4BNB05400010.10 41.50 FC4BNF03800010.00 40.00 FC4BNF04200010.10 41.00 FC4BNF04800010.00 10.10 40.00 FG3AAA04800010.50 41.00 FK4BNB00500011.00 41.50 FK4BNB00600010.50 40.00 FK4BNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0701AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0701AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketN/A
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0003
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow
10.00 10.10 39.50 CB5AXA04800010.00 10.10 40.00 CC5AXA04200010.00 10.10 39.50 CC5AXC04800010.00 10.10 40.00 CC5AXW04200010.00 10.10 40.00 CC5AXW04800010.00 10.10 40.00 CD5AXA04200010.00 10.10 40.00 CD5AXA04800010.00 10.10 39.50 CD5AXC04800010.00 10.10 40.00 CD5AXW04200010.00 10.10 40.00 CD5AXW04800010.00 10.10 40.00 CD5BXA04200010.00 10.10 40.00 CD5BXA04800010.00 10.10 39.50 CD5BXC04800010.00 10.10 40.00 CD5BXW04200010.00 10.10 40.00 CD5BXW04800010.00 10.10 40.50 CF5AXA04800010.00 10.10 40.50 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal
10.00 10.10 40.00 CD3AXA04200010.00 10.10 40.00 CD3AXA04800010.00 10.10 40.00 CD3BXA04200010.00 10.10 40.00 CD3BXA048000
10.00 38.00 CD3CXA04200010.00 10.10 39.50 CE3AXA04200010.00 10.10 40.50 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 15: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/15.jpg)
38CKB04830 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.50 10.50 47.00 FA4ANB04800010.50 10.50 48.00 FA4ANB06000010.50 10.50 47.00 FA4ANF04800010.50 10.50 48.00 FA4ANF06000010.50 10.50 47.00 FB4ANB04800010.50 10.50 48.00 FB4ANB06000011.00 11.00 49.00 FB4ANB07000010.50 10.50 47.00 FB4ANF04800010.50 10.50 48.00 FB4ANF06000010.50 47.00 FC4BNB04800011.00 48.50 FC4BNB05400010.50 47.50 FC4BNB06000011.00 48.50 FC4BNB07000010.50 47.00 FC4BNF04800010.50 47.50 FC4BNF06000010.00 10.50 46.00 FG3AAA04800010.20 10.50 47.00 FG3AAA06000011.50 49.00 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2001CYL
Support FeetN/A
TXV (RPB)KAATX0601RPB
Vinyl CoverP166-0004
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.20 46.00 CB5AXA04800010.00 10.50 46.00 CC5AXA06000010.00 10.50 45.00 CC5AXC04800010.00 10.50 46.00 CC5AXW04800010.20 10.50 47.50 CC5AXW06000010.00 10.50 46.00 CD5AXA04800010.00 10.50 46.00 CD5AXA06000010.00 10.50 45.00 CD5AXC04800010.00 10.50 46.00 CD5AXW04800010.20 10.50 47.50 CD5AXW06000010.00 10.50 46.00 CD5BXA04800010.00 10.50 46.00 CD5BXA06000010.00 10.50 45.00 CD5BXC04800010.00 10.50 46.00 CD5BXW04800010.20 10.50 47.50 CD5BXW06000010.20 10.50 46.00 CF5AXA04800010.20 10.50 46.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.50 46.00 CD3AXA04800010.20 10.50 46.00 CD3AXA06000010.00 10.50 46.00 CD3BXA04800010.20 10.50 46.00 CD3BXA060000
10.00 45.50 CD3CXA04800010.20 10.50 46.50 CE3AXA04800010.20 10.50 48.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 16: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/16.jpg)
38CKB06030 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.50 57.50 FA4ANB060000
10.00 10.50 57.50 FA4ANF060000
10.00 10.50 57.50 FB4ANB060000
10.50 58.00 FB4ANB070000
10.00 10.50 57.50 FB4ANF060000
10.00 57.50 FC4BNB054000
10.00 57.00 FC4BNB060000
10.50 58.00 FC4BNB070000
10.00 57.00 FC4BNF060000
10.00 10.20 56.50 FG3AAA060000
11.00 58.00 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2001CYL
Support FeetN/A
TXV (RPB)KAATX0701RPB
Vinyl CoverP166-0005
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.50 54.50 CC5AXA060000
10.00 10.50 57.00 CC5AXW060000
10.00 10.50 54.50 CD5AXA060000
10.00 10.50 57.00 CD5AXW060000
10.00 10.50 54.50 CD5BXA060000
10.00 10.50 57.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.50 54.50 CD3AXA060000
10.00 10.50 54.50 CD3BXA060000
10.00 10.50 56.00 CD3CXA060000
10.00 10.50 57.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 17: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/17.jpg)
38CMB01830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.50 10.50 17.00 FB4ANA018000
11.00 11.00 18.00 FB4ANA024000
10.50 10.50 17.00 FB4ANF018000
11.00 11.00 18.00 FB4ANF024000
10.50 10.50 17.00 FB5ANA018000
11.00 11.00 18.00 FB5ANA024000
10.50 10.50 17.00 FB5ANF018000
11.00 11.00 18.00 FB5ANF024000
11.00 18.00 FC4BNF024000
11.00 18.50 FC4BNF033000
10.00 10.50 17.00 FD3ANA018000
10.50 11.00 17.50 FD3ANA024000
10.50 11.00 17.00 FF1ANA018000
10.70 11.20 18.00 FF1ANA024000
10.50 11.00 17.00 FF1BNA018000
10.70 11.20 18.00 FF1BNA024000
10.50 11.00 17.50 FG3AAA024000
12.50 18.50 FK4BNF001000
12.70 18.50 FK4BNF002000
13.00 18.50 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart Sensor ConnectorBoard
ZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover 7-DayProgrammable
TSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX0901HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Ball Bearing Fan MotorHC34GE231
Crankcase HeaterKAACH1001AAA
Evap Freeze ThermostatKAAFT0101AAA
Low-Ambient ControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1301TEC
Support FeetN/A
TXV (RPB)KAATX0201RPB
Vinyl CoverP166-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.20 10.50 17.00 CC5AXA018000
10.50 11.00 17.50 CC5AXA024000
10.50 11.00 17.50 CC5AXW024000
10.20 10.50 17.00 CD5AXA018000
10.50 11.00 17.50 CD5AXA024000
10.50 11.00 17.50 CD5AXW024000
10.20 10.50 17.00 CD5BXA018000
10.50 11.00 17.50 CD5BXA024000
10.50 11.00 17.50 CD5BXW024000
10.50 11.00 17.50 CF5AXA024000
10.50 11.00 17.50 CG5AXA024000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 10.50 17.00 CD3AXA018000
10.50 11.00 17.50 CD3AXA024000
10.20 10.50 17.00 CD3BXA018000
10.50 11.00 17.50 CD3BXA024000
10.50 11.00 17.50 CD3CXA024000
10.50 11.00 17.50 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 18: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/18.jpg)
38CMB02430 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 23.20 FA4ANF024000
11.20 11.20 23.60 FA4ANF030000
11.00 11.00 23.20 FB4ANF024000
11.20 11.20 23.60 FB4ANF030000
10.80 23.20 FC4BNF024000
11.20 23.60 FC4BNF030000
11.40 24.00 FC4BNF033000
10.60 11.00 22.80 FD3ANA024000
10.80 11.20 23.80 FD3ANA030000
10.50 11.00 23.20 FF1ANA024000
10.80 11.20 23.80 FF1ANA030000
10.50 11.00 23.20 FF1BNA024000
10.80 11.20 23.80 FF1BNA030000
10.40 10.80 22.80 FG3AAA024000
13.00 25.00 FK4BNB005000
12.30 24.60 FK4BNF001000
12.50 24.80 FK4BNF002000
12.80 25.00 FK4BNF003000
12.80 25.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1301TEC
Support FeetN/A
TXV (RPB)KAATX0301RPB
Vinyl CoverP166-0015
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 11.00 23.00 CC5AXA024000
10.50 11.00 23.40 CC5AXA030000
10.50 11.00 23.00 CC5AXW024000
10.50 11.00 23.40 CC5AXW030000
10.50 11.00 23.00 CD5AXA024000
10.50 11.00 23.40 CD5AXA030000
10.50 11.00 23.00 CD5AXW024000
10.50 11.00 23.40 CD5AXW030000
10.50 11.00 23.00 CD5BXA024000
10.50 11.00 23.40 CD5BXA030000
10.50 11.00 23.00 CD5BXW024000
10.50 11.00 23.40 CD5BXW030000
10.50 11.00 23.20 CF5AXA024000
10.50 11.00 23.20 CG5AXA024000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 11.00 23.00 CD3AXA024000
10.50 11.00 23.40 CD3AXA030000
10.50 11.00 23.00 CD3BXA024000
10.50 11.00 23.40 CD3BXA030000
10.50 11.00 23.00 CD3CXA024000
10.50 11.00 23.20 CE3AXA024000
10.70 11.20 23.60 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 19: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/19.jpg)
38CMB03030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 28.80 FA4ANF030000
10.80 10.80 29.40 FA4ANF036000
11.00 11.00 28.80 FB4ANF030000
10.80 10.80 29.40 FB4ANF036000
11.00 28.80 FC4BNF030000
11.20 30.00 FC4BNF033000
10.80 29.40 FC4BNF036000
10.50 10.80 29.00 FD3ANA030000
10.70 11.00 29.00 FF1ANA030000
10.70 11.00 29.00 FF1BNA030000
10.70 11.00 29.40 FG3AAA036000
12.50 31.00 FK4BNB005000
12.00 29.00 FK4BNF001000
12.00 29.20 FK4BNF002000
12.00 30.00 FK4BNF003000
12.00 30.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0301AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1301TEC
Support FeetN/A
TXV (RPB)KAATX0401RPB
Vinyl CoverP166-0015
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 10.80 28.60 CC5AXA030000
10.70 11.00 29.60 CC5AXA036000
10.50 10.80 28.60 CC5AXW030000
10.50 10.80 28.60 CD5AXA030000
10.70 11.00 29.60 CD5AXA036000
10.50 10.80 28.60 CD5AXW030000
10.70 11.00 29.60 CD5AXW036000
10.50 10.80 28.60 CD5BXA030000
10.70 11.00 29.60 CD5BXA036000
10.50 10.80 28.60 CD5BXW030000
10.70 11.00 29.60 CD5BXW036000
10.70 11.00 29.60 CF5AXA036000
10.70 11.00 29.60 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 10.80 28.60 CD3AXA030000
10.70 11.00 29.60 CD3AXA036000
10.50 10.80 28.60 CD3BXA030000
10.70 11.00 29.60 CD3BXA036000
10.50 10.70 28.00 CD3CXA030000
10.60 10.80 28.80 CD3CXA036000
10.70 11.00 28.80 CE3AXA030000
10.70 11.00 29.20 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 20: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/20.jpg)
38CMB03630 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 35.00 FA4ANB042000
10.80 10.80 34.40 FA4ANF036000
11.00 11.00 35.00 FA4ANF042000
11.00 11.00 35.00 FB4ANB042000
10.80 10.80 34.40 FB4ANF036000
11.00 11.00 35.00 FB4ANF042000
11.00 35.00 FC4BNB042000
11.80 36.00 FC4BNB054000
11.00 35.00 FC4BNF033000
10.80 34.40 FC4BNF036000
11.30 36.00 FC4BNF038000
11.00 35.00 FC4BNF042000
10.70 11.00 34.40 FG3AAA036000
12.20 36.00 FK4BNB005000
12.50 36.00 FK4BNB006000
11.50 34.20 FK4BNF001000
11.50 34.40 FK4BNF002000
11.80 35.20 FK4BNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1901CYL
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0017
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.70 11.00 35.00 CC5AXA036000
10.70 11.00 35.00 CC5AXA042000
10.70 11.00 34.60 CC5AXW042000
10.70 11.00 35.00 CD5AXA036000
10.70 11.00 35.00 CD5AXA042000
10.70 11.00 35.00 CD5AXW036000
10.70 11.00 34.60 CD5AXW042000
10.70 11.00 35.00 CD5BXA036000
10.70 11.00 35.00 CD5BXA042000
10.70 11.00 35.00 CD5BXW036000
10.70 11.00 34.60 CD5BXW042000
10.90 11.20 35.00 CF5AXA036000
10.90 11.20 34.80 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗,58MXA∗,
58PAV∗, 58TUA∗,58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.70 11.00 35.00 CD3AXA036000
10.70 11.00 35.00 CD3AXA042000
10.70 11.00 35.00 CD3BXA036000
10.70 11.00 35.00 CD3BXA042000
10.30 10.60 33.60 CD3CXA036000
10.70 11.00 34.00 CD3CXA048000
10.70 11.00 34.40 CE3AXA036000
10.90 11.20 35.20 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 21: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/21.jpg)
38CMB04230 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.80 10.80 40.50 FA4ANB042000
11.00 11.00 41.00 FA4ANB048000
10.80 10.80 40.50 FA4ANF042000
11.00 11.00 41.00 FA4ANF048000
10.80 10.80 40.50 FB4ANB042000
11.00 11.00 41.00 FB4ANB048000
10.80 10.80 40.50 FB4ANF042000
11.00 11.00 41.00 FB4ANF048000
10.80 40.50 FC4BNB042000
11.00 41.00 FC4BNB048000
11.50 42.00 FC4BNB054000
11.20 42.00 FC4BNF038000
10.80 40.50 FC4BNF042000
11.00 41.00 FC4BNF048000
10.80 11.10 40.50 FG3ANA048000
12.00 42.00 FK4BNB005000
12.50 42.00 FK4BNB006000
11.50 40.50 FK4BNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1901CYL
Support FeetN/A
TXV (RPB)KAATX0501RPB
Vinyl CoverP166-0004
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.70 11.00 40.50 CC5AXA042000
10.60 11.00 40.00 CC5AXC048000
10.70 11.00 40.00 CC5AXW042000
10.70 11.00 40.50 CC5AXW048000
10.70 11.00 40.50 CD5AXA042000
10.70 11.00 40.50 CD5AXA048000
10.60 11.00 40.00 CD5AXC048000
10.70 11.00 40.00 CD5AXW042000
10.70 11.00 40.50 CD5AXW048000
10.70 11.00 40.50 CD5BXA042000
10.70 11.00 40.50 CD5BXA048000
10.60 11.00 40.00 CD5BXC048000
10.70 11.00 40.00 CD5BXW042000
10.70 11.00 40.50 CD5BXW048000
10.70 11.00 41.00 CF5AXA048000
10.70 11.00 41.00 CG5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.70 11.00 40.50 CD3AXA042000
10.70 11.00 40.50 CD3AXA048000
10.70 11.00 40.50 CD3BXA042000
10.70 11.00 40.50 CD3BXA048000
10.20 10.50 38.00 CD3CXA042000
10.60 11.00 39.00 CD3CXA048000
10.70 11.00 40.50 CE3AXA042000
10.70 11.00 41.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 22: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/22.jpg)
38CMB04830 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.80 10.80 46.50 FA4ANB048000
11.00 11.00 48.00 FA4ANB060000
10.80 10.80 46.50 FA4ANF048000
11.00 11.00 48.00 FA4ANF060000
10.80 10.80 46.50 FB4ANB048000
11.00 11.00 48.00 FB4ANB060000
11.40 11.40 48.00 FB4ANB070000
10.80 10.80 46.50 FB4ANF048000
11.00 11.00 48.00 FB4ANF060000
11.00 46.50 FC4BNB048000
11.40 48.00 FC4BNB054000
11.00 48.00 FC4BNB060000
11.40 48.00 FC4BNB070000
11.00 46.50 FC4BNF048000
11.00 48.00 FC4BNF060000
10.50 10.80 46.00 FG3AAA048000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2001CYL
Support FeetN/A
TXV (RPB)KAATX0601RPB
Vinyl CoverP166-0007
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.60 11.00 46.00 CC5AXA060000
10.40 10.80 45.00 CC5AXC048000
10.50 10.80 46.00 CC5AXW048000
10.80 11.10 47.50 CC5AXW060000
10.50 10.80 46.00 CD5AXA048000
10.60 11.00 46.00 CD5AXA060000
10.40 10.80 45.00 CD5AXC048000
10.50 10.80 46.00 CD5AXW048000
10.80 11.10 47.50 CD5AXW060000
10.50 10.80 46.00 CD5BXA048000
10.60 11.00 46.00 CD5BXA060000
10.40 10.80 45.00 CD5BXC048000
10.50 10.80 46.00 CD5BXW048000
10.80 11.10 47.50 CD5BXW060000
10.70 11.00 46.00 CF5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 10.80 46.00 CD3AXA048000
10.60 11.00 46.00 CD3AXA060000
10.50 10.80 46.00 CD3BXA048000
10.60 11.00 46.00 CD3BXA060000
10.30 10.70 44.00 CD3CXA048000
10.60 11.00 46.00 CD3CXA060000
10.70 11.00 46.50 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 23: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/23.jpg)
38CMB06030 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.70 10.70 56.50 FA4ANB060000
10.70 10.70 56.50 FA4ANF060000
10.70 10.70 56.50 FB4ANB060000
11.00 11.00 57.50 FB4ANB070000
10.70 10.70 56.50 FB4ANF060000
11.20 57.00 FC4BNB054000
10.70 56.50 FC4BNB060000
11.00 57.50 FC4BNB070000
10.70 56.50 FC4BNF060000
10.70 11.00 56.00 FG3AAA060000
11.30 57.50 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Motormaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0501LRG
Cycle ProtectorStandard
Equipment PadP152-3030
Fan Control CenterP211-4013
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH2001CYL
Support FeetN/A
TXV (RPB)KAATX0701RPB
Vinyl CoverP166-0006
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.60 10.80 54.00 CC5AXA060000
10.80 11.00 56.00 CC5AXW060000
10.60 10.80 54.00 CD5AXA060000
10.80 11.00 56.00 CD5AXW060000
10.60 10.80 54.00 CD5BXA060000
10.80 11.00 56.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.60 10.80 54.00 CD3AXA060000
10.60 10.80 54.00 CD3BXA060000
10.50 10.70 54.00 CD3CXA060000
10.70 10.90 55.00 CD3CXA070000
10.80 11.00 56.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 24: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/24.jpg)
38TDA03630 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.55 36.00 FA4ANF036000
12.55 36.00 FB4ANF036000
17.10 40.00 FK4CNB006000
15.00 36.20 FK4CNF001000
15.50 36.40 FK4CNF002000
16.00 37.00 FK4CNF003000
16.50 39.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. May not be required for application. Consult zoning information.
Barometric Bypass9
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Outdoor SensorTSTATCCSEN01
None
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP502-8163S
Start CapacitorStandard
Crankcase HeaterStandard
Start CapacitorStandard
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Filter DrierP502-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow13.60 37.60 CC5AXA036000
13.70 37.60 CC5AXW048000
14.00 38.50 CC5AXW060000
13.60 37.60 CD5AXA036000
13.70 37.60 CD5AXA048000
13.60 37.60 CD5AXW036000
13.70 37.60 CD5AXW048000
14.00 38.50 CD5AXW060000
13.60 37.60 CD5BXA036000
13.70 37.60 CD5BXA048000
13.60 37.60 CD5BXW036000
13.70 37.60 CD5BXW048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.70 37.60 CD3AXA036000
13.70 37.60 CD3AXA048000
13.60 37.60 CD3BXA036000
13.70 37.60 CD3BXA048000
13.50 37.20 CE3AXA036000
13.60 37.60 CE3AXA042000
13.80 37.80 CE3AXA048000
14.00 38.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN5
FURNACE COILS - Two Speed15.60 37.00 CC5AXA036000
15.60 37.00 CC5AXA042000
15.80 37.40 CC5AXA060000
15.50 37.00 CC5AXW042000
15.80 37.40 CC5AXW048000
16.10 38.00 CC5AXW060000
15.60 37.00 CD3AXA036000
15.60 37.00 CD3AXA042000
15.80 37.40 CD3AXA048000
15.80 37.40 CD3AXA060000
15.60 37.00 CD3BXA036000
15.60 37.00 CD3BXA042000
15.80 37.40 CD3BXA048000
15.80 37.40 CD3BXA060000
15.60 37.00 CD5AXA036000
15.60 37.00 CD5AXA042000
15.80 37.40 CD5AXA048000
15.80 37.40 CD5AXA060000
15.60 37.00 CD5AXW036000
15.50 37.00 CD5AXW042000
15.80 37.40 CD5AXW048000
16.10 38.00 CD5AXW060000
15.60 37.00 CD5BXA036000
15.60 37.00 CD5BXA042000
15.80 37.40 CD5BXA048000
15.80 37.40 CD5BXA060000
15.60 37.00 CD5BXW036000
15.50 37.00 CD5BXW042000
15.90 37.40 CD5BXW048000
16.10 38.00 CD5BXW060000
Furnan Blk 4
Down/Upflow58MVP100---1--20
![Page 25: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/25.jpg)
38TDA04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.80 48.50 FA4ANB048000
11.50 49.50 FA4ANB060000
11.80 48.50 FA4ANF048000
11.50 49.50 FA4ANF060000
11.80 48.50 FB4ANB048000
11.50 49.50 FB4ANB060000
11.80 48.50 FB4ANF048000
11.50 49.50 FB4ANF060000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. May not be required for application. Consult zoning information.
Barometric Bypass9
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable
TSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Outdoor SensorTSTATCCSEN01
None
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP502-8163S
Start CapacitorStandard
Crankcase HeaterStandard
Start CapacitorStandard
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Filter DrierStandard
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.80 48.50 CC5AXA060000
12.70 48.00 CC5AXW048000
13.00 50.00 CC5AXW060000
12.80 48.00 CD5AXA048000
12.80 48.50 CD5AXA060000
12.70 48.00 CD5AXW048000
13.00 50.00 CD5AXW060000
12.80 48.00 CD5BXA048000
12.80 48.50 CD5BXA060000
12.70 48.00 CD5BXW048000
13.00 50.00 CD5BXW060000
12.80 48.50 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.80 48.00 CD3AXA048000
12.80 48.50 CD3AXA060000
12.80 48.00 CD3BXA048000
12.80 48.50 CD3BXA060000
12.80 48.50 CE3AXA048000
13.00 50.00 CE3AXA060000
Furnan Blk 4Horizontal
58EFA, 58EJB∗,58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN5
FURNACE COILS - Two Speed13.85 48.50 CC5AXA060000
13.50 46.50 CC5AXC048000
13.85 47.00 CC5AXW048000
14.30 49.00 CC5AXW060000
13.85 47.00 CD3AXA048000
13.85 48.50 CD3AXA060000
13.85 47.00 CD3BXA048000
13.85 48.50 CD3BXA060000
13.85 47.00 CD5AXA048000
13.85 48.50 CD5AXA060000
13.50 46.50 CD5AXC048000
13.85 47.00 CD5AXW048000
14.30 49.00 CD5AXW060000
13.85 47.00 CD5BXA048000
13.85 48.50 CD5BXA060000
13.50 46.50 CD5BXC048000
13.85 47.00 CD5BXW048000
14.30 49.00 CD5BXW060000
13.80 48.50 CE3AXA048000
14.30 49.00 CE3AXA060000
Furnan Blk 4
Down/Upflow58MVP100---1--20
![Page 26: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/26.jpg)
38TDA06030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.25 56.50 FA4ANB060000
11.25 56.50 FA4ANF060000
11.25 56.50 FB4ANB060000
11.25 56.50 FB4ANF060000
14.70 58.50 FK4CNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. May not be required for application. Consult zoning information.
Barometric Bypass9
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular DampersDAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable
TSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Outdoor SensorTSTATCCSEN01
None
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP502-8163S
Start CapacitorStandard
Crankcase HeaterStandard
Start CapacitorStandard
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Filter DrierP502-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.20 55.00 CC5AXA060000
12.50 56.50 CC5AXW060000
12.20 55.00 CD5AXA060000
12.50 56.50 CD5AXW060000
12.20 55.00 CD5BXA060000
12.50 56.50 CD5BXW060000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.20 56.50 CD3AXA060000
12.20 56.50 CD3BXA060000
12.50 57.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN5
FURNACE COILS - Two Speed13.40 53.00 CC5AXA060000
13.50 55.00 CC5AXW060000
13.40 53.00 CD3AXA060000
13.40 53.00 CD3BXA060000
13.40 53.00 CD5AXA060000
13.50 55.00 CD5AXW060000
13.40 53.00 CD5BXA060000
13.50 55.00 CD5BXW060000
13.50 55.00 CE3AXA060000
Furnan Blk 4
Down/Upflow58MVP100---1--20
![Page 27: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/27.jpg)
38TKB01830 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.00 16.80 FA4ANF018000
10.50 10.50 17.60 FA4ANF024000
10.00 10.00 16.80 FB4ANF018000
10.00 10.50 17.60 FB4ANF024000
10.50 17.60 FC4BNF024000
10.00 17.10 FD3ANA018000
10.00 10.50 17.60 FD3ANA024000
10.50 10.50 17.00 FF1ANA018000
10.50 10.50 17.60 FF1ANA024000
10.50 10.50 17.00 FF1BNA018000
10.50 10.50 17.60 FF1BNA024000
10.00 10.20 17.50 FG3AAA024000
12.00 18.00 FK4BNF001000
12.00 18.00 FK4BNF002000
12.50 18.00 FK4BNF004000
12.00 18.00 FK4CNF001000
12.00 18.00 FK4CNF002000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass4
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX0901HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0101SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
Hail GuardKAAHG0106MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1101COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0201RPB
Vinyl CoverP161-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.20 17.20 CC5AXA018000
10.00 10.50 17.60 CC5AXA024000
10.00 10.50 17.60 CC5AXW024000
10.00 10.20 17.20 CD5AXA018000
10.00 10.50 17.60 CD5AXA024000
10.00 10.50 17.60 CD5AXW024000
10.00 10.20 17.20 CD5BXA018000
10.00 10.50 17.60 CD5BXA024000
10.00 10.50 17.60 CD5BXW024000
10.00 10.50 17.80 CF5AXA024000
10.00 10.50 17.80 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.20 17.00 CD3AXA018000
10.00 10.50 17.60 CD3AXA024000
10.00 10.20 17.00 CD3BXA018000
10.00 10.50 17.60 CD3BXA024000
10.00 10.50 17.60 CD3CXA024000
10.00 10.50 17.80 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 28: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/28.jpg)
38TKB02430 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.00 22.20 FA4ANF024000
10.20 10.20 23.00 FA4ANF030000
10.00 10.00 22.20 FB4ANF024000
10.20 10.20 23.00 FB4ANF030000
10.00 22.20 FC4BNF024000
10.20 23.00 FC4BNF030000
10.00 21.60 FD3ANA024000
10.00 22.40 FD3ANA030000
10.00 10.00 22.20 FF1ANA024000
10.00 10.00 22.40 FF1ANA030000
10.00 10.00 22.20 FF1BNA024000
10.00 10.00 22.40 FF1BNA030000
10.00 21.40 FG3ANA024000
11.00 23.60 FK4BNF001000
11.00 23.80 FK4BNF002000
11.50 23.60 FK4BNF003000
11.50 23.80 FK4BNF004000
11.00 23.60 FK4CNF001000
11.00 23.80 FK4CNF002000
11.50 23.60 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass4
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0101SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
Hail GuardKAAHG0106MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1101COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0301RPB
Vinyl CoverP161-0001
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.20 22.40 CC5AXA024000
10.00 10.20 22.40 CC5AXA030000
10.00 10.20 22.20 CC5AXW024000
10.00 10.20 22.40 CC5AXW030000
10.00 10.20 22.40 CD5AXA024000
10.00 10.20 22.40 CD5AXA030000
10.00 10.20 22.20 CD5AXW024000
10.00 10.20 22.40 CD5AXW030000
10.00 10.20 22.40 CD5BXA024000
10.00 10.20 22.40 CD5BXA030000
10.00 10.20 22.20 CD5BXW024000
10.00 10.20 22.40 CD5BXW030000
10.00 10.20 22.20 CF5AXA024000
10.00 10.20 22.20 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗, 58PAV∗,58TUA∗, 58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.20 22.20 CD3AXA024000
10.00 10.20 22.40 CD3AXA030000
10.00 10.20 22.20 CD3BXA024000
10.00 10.20 22.40 CD3BXA030000
10.00 22.00 CD3CXA024000
10.10 22.20 CD3CXA030000
10.00 10.20 22.40 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,
58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 29: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/29.jpg)
38TKB03030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.30 10.30 28.40 FA4ANF030000
10.00 10.00 28.20 FA4ANF036000
10.30 10.30 28.40 FB4ANF030000
10.00 10.00 28.20 FB4ANF036000
10.30 28.40 FC4BNF030000
10.00 28.20 FC4BNF036000
10.00 27.80 FD3ANA030000
10.00 10.10 28.00 FF1ANA030000
10.00 10.10 28.00 FF1BNA030000
10.00 10.50 28.00 FG3AAA036000
10.50 29.40 FK4BNF001000
10.50 29.60 FK4BNF002000
11.00 29.80 FK4BNF003000
11.00 29.80 FK4BNF004000
10.50 29.40 FK4CNF001000
10.50 29.60 FK4CNF002000
11.00 29.80 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1001AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Crankcase HeaterKAACH1001AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0101SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
Hail GuardKAAHG0206MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1201COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0401RPB
Vinyl CoverP161-0003
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.20 28.00 CC5AXA030000
10.00 10.50 29.00 CC5AXA036000
10.00 10.20 27.80 CC5AXW030000
10.00 10.20 28.00 CD5AXA030000
10.00 10.50 29.00 CD5AXA036000
10.00 10.20 27.80 CD5AXW030000
10.00 10.50 29.00 CD5AXW036000
10.00 10.20 28.00 CD5BXA030000
10.00 10.50 29.00 CD5BXA036000
10.00 10.20 27.80 CD5BXW030000
10.00 10.50 29.00 CD5BXW036000
10.00 10.50 28.80 CF5AXA036000
10.00 10.50 28.00 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗,
58PAV∗, 58TUA∗,58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 10.20 27.80 CD3AXA030000
10.00 10.50 29.00 CD3AXA036000
10.00 10.20 27.80 CD3BXA030000
10.00 10.50 29.00 CD3BXA036000
10.00 10.20 27.40 CD3CXA030000
10.00 10.20 28.00 CD3CXA036000
10.00 10.30 27.80 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 30: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/30.jpg)
38TKB03630 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.00 10.00 33.40 FA4ANB042000
10.00 10.00 32.40 FA4ANF036000
10.00 10.00 33.40 FA4ANF042000
10.00 10.00 33.40 FB4ANB042000
10.00 10.00 32.40 FB4ANF036000
10.00 10.00 33.40 FB4ANF042000
10.00 33.40 FC4BNB042000
10.20 33.40 FC4BNF033000
10.00 32.40 FC4BNF036000
10.50 34.60 FC4BNF038000
10.00 33.40 FC4BNF042000
10.00 32.20 FG3AAA036000
11.50 35.00 FK4BNB005000
11.50 35.00 FK4BNB006000
10.50 32.80 FK4BNF001000
10.50 32.80 FK4BNF002000
11.00 33.40 FK4BNF003000
11.00 33.40 FK4BNF004000
11.50 35.00 FK4CNB006000
10.50 32.80 FK4CNF001000
10.50 32.80 FK4CNF002000
11.00 33.40 FK4CNF003000
11.50 35.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0601AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0101SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
Hail GuardKAAHG0206MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1201COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0501RPB
Vinyl CoverP161-0003
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 10.20 33.40 CC5AXA036000
10.00 10.20 33.40 CC5AXA042000
10.00 10.20 33.00 CC5AXW042000
10.00 10.20 33.40 CD5AXA036000
10.00 10.20 33.40 CD5AXA042000
10.00 10.20 33.40 CD5AXW036000
10.00 10.20 33.00 CD5AXW042000
10.00 10.20 33.40 CD5BXA036000
10.00 10.20 33.40 CD5BXA042000
10.00 10.20 33.40 CD5BXW036000
10.00 10.20 33.00 CD5BXW042000
10.00 10.20 33.20 CF5AXA036000
10.00 10.20 33.20 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗,58PAV∗,58TMA∗,
58TUA∗, 58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3FURNACE COILS - Horizontal
10.00 10.20 33.00 CD3AXA036000
10.00 10.20 33.40 CD3AXA042000
10.00 10.20 33.00 CD3BXA036000
10.00 10.20 33.40 CD3BXA042000
10.00 32.00 CD3CXA036000
10.00 32.00 CD3CXA042000
10.00 10.20 33.00 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 31: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/31.jpg)
38TKB04230 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS
10.00 10.00 40.00 FA4ANB042000
10.50 10.50 41.00 FA4ANB048000
10.00 10.00 40.00 FA4ANF042000
10.50 10.50 41.00 FA4ANF048000
10.00 10.00 40.00 FB4ANB042000
10.50 10.50 41.00 FB4ANB048000
10.00 10.00 40.00 FB4ANF042000
10.50 10.50 41.00 FB4ANF048000
10.00 40.00 FC4BNB042000
10.50 41.00 FC4BNB048000
11.00 41.50 FC4BNB054000
10.50 41.00 FC4BNF038000
10.00 40.00 FC4BNF042000
10.50 41.00 FC4BNF048000
10.00 10.50 40.00 FG3AAA048000
11.50 42.00 FK4BNB005000
11.50 42.00 FK4BNB006000
11.00 40.50 FK4BNF003000
11.50 42.00 FK4CNB006000
11.00 40.50 FK4CNF003000
11.50 42.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0701AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0701AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-4147
Fan Control CenterP211-4013
Filter DrierP502-8163S
Hail GuardKAAHG0206MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1201COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0501RPB
Vinyl CoverP161-0005
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06SB(15 FT )
P850-30614-06SB(20 FT )
P850-40614-06SB(25 FT )
P850-50614-06SB(30 FT )
P850-60614-06SB(35 FT )
P850-70614-06SB(40 FT )
P850-90614-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow
10.20 10.50 40.00 CC5AXA042000
10.00 10.50 40.00 CC5AXC048000
10.00 10.50 40.00 CC5AXW042000
10.00 10.50 40.00 CC5AXW048000
10.20 10.50 40.00 CD5AXA042000
10.00 10.50 40.00 CD5AXA048000
10.00 10.50 40.00 CD5AXC048000
10.00 10.50 40.00 CD5AXW042000
10.00 10.50 40.00 CD5AXW048000
10.20 10.50 40.00 CD5BXA042000
10.00 10.50 40.00 CD5BXA048000
10.00 10.50 40.00 CD5BXC048000
10.00 10.50 40.00 CD5BXW042000
10.00 10.50 40.00 CD5BXW048000
10.00 10.50 41.00 CF5AXA048000
10.00 10.50 41.00 CG5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal
10.00 10.50 40.00 CD3AXA042000
10.00 10.50 40.00 CD3AXA048000
10.00 10.50 40.00 CD3BXA042000
10.00 10.50 40.00 CD3BXA048000
10.00 38.00 CD3CXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 32: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/32.jpg)
38TKB04831 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS
10.50 10.50 46.00 FA4ANB048000
10.50 10.50 47.50 FA4ANB060000
10.50 10.50 46.00 FA4ANF048000
10.50 10.50 47.50 FA4ANF060000
10.50 10.50 46.00 FB4ANB048000
10.50 10.50 47.50 FB4ANB060000
10.70 10.70 48.00 FB4ANB070000
10.50 10.50 46.00 FB4ANF048000
10.50 10.50 47.50 FB4ANF060000
10.40 46.50 FC4BNB048000
10.70 48.00 FC4BNB054000
10.50 47.50 FC4BNB060000
10.70 48.00 FC4BNB070000
10.40 46.50 FC4BNF048000
10.50 47.50 FC4BNF060000
10.00 10.50 45.50 FG3AAA048000
10.30 10.50 47.00 FG3AAA060000
11.00 48.00 FK4BNB006000
11.00 48.00 FK4CNB006000
11.00 47.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See price pages for complete listing of line sets.6. Size dependent on home duct size.7. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass6
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers6
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers6
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-4147
Fan Control CenterP211-4013
Filter DrierP502-8163S
Hail GuardKAAHG0206MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1701COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0601RPB
Vinyl CoverP161-0005
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06SB(15 FT )
P850-30614-06SB(20 FT )
P850-40614-06SB(25 FT )
P850-50614-06SB(30 FT )
P850-60614-06SB(35 FT )
P850-70614-06SB(40 FT )
P850-90614-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow
10.00 10.50 46.50 CC5AXA060000
10.00 10.50 45.00 CC5AXC048000
10.00 10.20 46.00 CC5AXW048000
10.00 10.50 47.50 CC5AXW060000
10.00 10.50 46.00 CD5AXA048000
10.00 10.50 46.50 CD5AXA060000
10.00 10.50 45.00 CD5AXC048000
10.00 10.20 46.00 CD5AXW048000
10.00 10.50 47.50 CD5AXW060000
10.00 10.50 46.00 CD5BXA048000
10.00 10.50 46.50 CD5BXA060000
10.00 10.50 45.00 CD5BXC048000
10.00 10.20 46.00 CD5BXW048000
10.00 10.50 47.50 CD5BXW060000
10.30 10.50 46.00 CF5AXA048000
10.30 10.50 46.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗,
58PAV∗, 58TUA∗,58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3FURNACE COILS - Horizontal
10.00 10.50 46.00 CD3AXA048000
10.00 10.50 46.50 CD3AXA060000
10.00 10.50 46.00 CD3BXA048000
10.00 10.50 46.50 CD3BXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE7
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 33: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/33.jpg)
38TKB06031 (82 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS
10.50 10.50 57.50 FA4ANB060000
10.50 10.50 57.50 FA4ANF060000
10.50 10.50 57.50 FB4ANB060000
11.00 11.00 58.50 FB4ANB070000
10.50 10.50 57.50 FB4ANF060000
10.50 57.40 FC4BNB060000
11.00 58.50 FC4BNB070000
10.50 57.40 FC4BNF060000
10.30 10.70 57.00 FG3AAA060000
11.00 58.00 FK4BNB006000
11.00 58.00 FK4CNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-4147
Fan Control CenterP211-4013
Filter DrierP502-8163S
Hail GuardKAAHG0206MPK
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketKSASH1701COP
Support FeetKSASF0101AAA
TXV (RPB)KAATX0701RPB
Vinyl CoverP161-0005
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow
10.30 10.50 55.00 CC5AXA060000
10.30 10.50 57.50 CC5AXW060000
10.30 10.50 55.00 CD5AXA060000
10.30 10.50 57.50 CD5AXW060000
10.30 10.50 55.00 CD5BXA060000
10.30 10.50 57.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal
10.30 10.50 55.00 CD3AXA060000
10.30 10.50 55.00 CD3BXA060000
10.30 10.50 55.00 CD3CXA060000
10.30 10.50 55.50 CD3CXA070000
10.50 10.80 58.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 34: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/34.jpg)
38TRA01830 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.50 11.50 17.50 FA4ANF018000
12.00 12.00 18.00 FA4ANF024000
11.50 11.50 17.50 FB4ANF018000
12.00 12.00 18.00 FB4ANF024000
12.00 18.00 FC4BNF024000
12.00 18.50 FC4BNF033000
11.20 17.50 FD3ANA018000
12.20 18.00 FD3ANA024000
12.20 12.20 17.50 FF1ANA018000
12.20 12.20 18.00 FF1ANA024000
12.20 12.20 17.50 FF1BNA018000
12.20 12.20 18.00 FF1BNA024000
12.00 18.00 FG3AAA024000
13.50 19.00 FK4BNF001000
14.00 19.00 FK4BNF002000
14.00 19.00 FK4BNF004000
13.50 19.00 FK4CNF001000
14.00 19.00 FK4CNF002000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX0901HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX0901HSO
TXV (RPB)KAATX0201RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 17.50 CC5AXA018000
12.00 18.00 CC5AXA024000
12.00 18.00 CC5AXW024000
11.50 17.50 CD5AXA018000
12.00 18.00 CD5AXA024000
12.00 18.00 CD5AXW024000
11.50 17.50 CD5BXA018000
12.00 18.00 CD5BXA024000
12.00 18.00 CD5BXW024000
12.00 17.50 CF5AXA024000
12.00 17.50 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗, 58PAV∗,58TUA∗, 58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.50 17.50 CD3AXA018000
12.00 18.00 CD3AXA024000
11.50 17.50 CD3BXA018000
12.00 18.00 CD3BXA024000
12.00 18.00 CD3CXA024000
12.00 17.50 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 35: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/35.jpg)
38TRA02431 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 23.60 FA4ANF024000
12.10 12.10 24.00 FA4ANF030000
12.00 12.00 23.60 FB4ANF024000
12.10 12.10 24.00 FB4ANF030000
12.00 23.60 FC4BNF024000
12.10 24.00 FC4BNF030000
12.50 24.00 FC4BNF033000
12.00 23.20 FD3ANA024000
12.10 24.00 FD3ANA030000
12.00 12.00 23.60 FF1ANA024000
12.10 12.10 24.00 FF1ANA030000
12.00 12.00 23.60 FF1BNA024000
12.10 12.10 24.00 FF1BNA030000
11.80 23.20 FG3AAA024000
13.00 24.00 FK4BNF001000
13.50 24.00 FK4BNF002000
14.00 24.00 FK4BNF003000
14.00 24.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass4
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1001HSO
TXV (RPB)KAATX0301RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 23.40 CC5AXA024000
12.10 23.60 CC5AXA030000
12.00 23.40 CC5AXW024000
12.10 23.60 CC5AXW030000
12.00 23.40 CD5AXA024000
12.10 23.60 CD5AXA030000
12.00 23.40 CD5AXW024000
12.10 23.60 CD5AXW030000
12.00 23.40 CD5BXA024000
12.10 23.60 CD5BXA030000
12.00 23.40 CD5BXW024000
12.10 23.60 CD5BXW030000
12.00 23.60 CF5AXA024000
12.00 23.60 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,
58MVP∗,58MXA∗, 58PAV∗,58TUA∗, 58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 23.40 CD3AXA024000
12.10 23.60 CD3AXA030000
12.00 23.40 CD3BXA024000
12.10 23.60 CD3BXA030000
12.00 23.60 CD3CXA024000
12.00 23.60 CD3CXA030000
12.00 23.60 CE3AXA024000
12.10 24.00 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗,58MXA∗,58RAV∗,
58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 36: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/36.jpg)
38TRA03031 (70 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 29.40 FA4ANF030000
12.00 12.00 30.00 FA4ANF036000
12.00 12.00 29.40 FB4ANF030000
12.00 12.00 30.00 FB4ANF036000
12.00 29.40 FC4BNF030000
12.50 30.00 FC4BNF033000
12.00 30.00 FC4BNF036000
12.00 29.40 FD3ANA030000
12.00 12.00 30.00 FF1ANA030000
12.00 12.00 30.00 FF1BNA030000
12.50 30.00 FG3AAA036000
13.50 29.60 FK4BNF001000
13.50 29.60 FK4BNF002000
14.00 30.00 FK4BNF003000
14.00 30.00 FK4BNF004000
13.50 29.60 FK4CNF001000
13.50 29.60 FK4CNF002000
14.00 30.00 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1101HSO
TXV (RPB)KAATX0401RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 29.60 CC5AXA030000
12.50 30.00 CC5AXA036000
12.00 29.60 CC5AXW030000
12.00 29.60 CD5AXA030000
12.50 30.00 CD5AXA036000
12.00 29.60 CD5AXW030000
12.50 30.00 CD5AXW036000
12.00 29.60 CD5BXA030000
12.50 30.00 CD5BXA036000
12.00 29.60 CD5BXW030000
12.50 30.00 CD5BXW036000
12.50 30.00 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 29.60 CD3AXA030000
12.50 30.00 CD3AXA036000
12.00 29.60 CD3BXA030000
12.50 30.00 CD3BXA036000
12.50 30.00 CD3CXA036000
12.00 29.40 CE3AXA030000
12.50 30.00 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 37: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/37.jpg)
38TRA03631 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 35.60 FA4ANB04200011.80 11.80 35.00 FA4ANF03600012.00 12.00 35.60 FA4ANF04200012.00 12.00 35.60 FB4ANB04200011.80 11.80 35.00 FB4ANF03600012.00 12.00 35.60 FB4ANF04200012.00 35.60 FC4BNB04200013.00 36.00 FC4BNB05400012.00 35.60 FC4BNF03300011.80 35.00 FC4BNF03600012.50 36.00 FC4BNF03800012.00 35.60 FC4BNF042000
12.00 35.00 FG3AAA03600013.50 36.00 FK4BNB00500013.50 36.00 FK4BNB00600012.50 35.00 FK4BNF00100012.50 35.00 FK4BNF00200013.00 35.40 FK4BNF00300013.00 35.40 FK4BNF00400014.00 36.00 FK4CNB00600012.50 35.00 FK4CNF00100012.50 35.00 FK4CNF00200013.00 35.40 FK4CNF00300013.50 36.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG,
Command Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR,Home Access Module ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN,Fuse Pack ZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1201HSO
TXV (RPB)KAATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 35.80 CC5AXA03600012.20 35.60 CC5AXA04200012.20 35.40 CC5AXW04200012.00 35.80 CD5AXA03600012.20 35.60 CD5AXA04200012.00 35.80 CD5AXW03600012.20 35.40 CD5AXW04200012.00 35.80 CD5BXA03600012.20 35.60 CD5BXA04200012.00 35.80 CD5BXW03600012.20 35.40 CD5BXW04200012.00 35.40 CF5AXA03600012.00 35.40 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 35.80 CD3AXA03600012.20 35.60 CD3AXA04200012.00 35.80 CD3BXA03600012.20 35.60 CD3BXA04200011.80 34.60 CD3CXA04200012.00 35.20 CE3AXA03600012.20 35.80 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 38: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/38.jpg)
38TRA04231 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 41.00 FA4ANB04200012.20 12.20 41.50 FA4ANB04800012.00 12.00 41.00 FA4ANF04200012.20 12.20 41.50 FA4ANF04800012.00 12.00 41.00 FB4ANB04200012.20 12.20 41.50 FB4ANB04800012.00 12.00 41.00 FB4ANF04200012.20 12.20 41.50 FB4ANF04800012.00 41.00 FC4BNB04200012.20 41.50 FC4BNB04800013.00 42.00 FC4BNB05400012.50 42.00 FC4BNF03800012.00 41.00 FC4BNF04200012.20 41.50 FC4BNF048000
12.00 41.00 FG3AAA04800013.50 42.00 FK4BNB00500013.50 42.00 FK4BNB00600012.50 41.00 FK4BNF00300014.00 42.00 FK4CNB00600012.50 41.00 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG,
Command Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR,Home Access Module ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN,Fuse Pack ZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1201HSO
TXV (RPB)KAATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 41.50 CC5AXA04200012.00 41.00 CC5AXC04800012.00 41.00 CC5AXW04200012.20 41.00 CC5AXW04800012.00 41.50 CD5AXA04200012.20 41.00 CD5AXA04800012.00 41.00 CD5AXC04800012.00 41.00 CD5AXW04200012.20 41.00 CD5AXW04800012.00 41.50 CD5BXA04200012.20 41.00 CD5BXA04800012.00 41.00 CD5BXC04800012.00 41.00 CD5BXW04200012.20 41.00 CD5BXW04800012.20 41.50 CF5AXA04800012.20 41.50 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 41.50 CD3AXA04200012.20 41.00 CD3AXA04800012.00 41.50 CD3BXA04200012.20 41.00 CD3BXA04800012.00 41.00 CD3CXA04800012.00 41.00 CE3AXA04200012.20 41.50 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 39: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/39.jpg)
38TRA04831 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.00 12.00 47.50 FA4ANB04800012.10 12.10 48.00 FA4ANB06000012.00 12.00 47.50 FA4ANF04800012.10 12.10 48.00 FA4ANF06000012.00 12.00 47.50 FB4ANB04800012.10 12.10 48.00 FB4ANB06000012.00 12.00 47.50 FB4ANF04800012.10 12.10 48.00 FB4ANF06000012.00 47.50 FC4BNB04800012.50 48.50 FC4BNB05400012.10 48.00 FC4BNB06000012.00 47.50 FC4BNF04800012.10 48.00 FC4BNF060000
12.00 47.50 FG3AAA04800012.10 48.00 FG3AAA060000
13.00 48.50 FK4BNB00600013.00 48.50 FK4CNB00600013.00 48.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1301HSO
TXV (RPB)KAATX0601RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 48.00 CC5AXA06000012.00 47.00 CC5AXC04800012.00 47.50 CC5AXW04800012.50 48.50 CC5AXW06000012.00 47.50 CD5AXA04800012.00 48.00 CD5AXA06000012.00 47.00 CD5AXC04800012.00 47.50 CD5AXW04800012.50 48.50 CD5AXW06000012.00 47.50 CD5BXA04800012.00 48.00 CD5BXA06000012.00 47.00 CD5BXC04800012.00 47.50 CD5BXW04800012.50 48.50 CD5BXW06000012.00 47.50 CF5AXA04800012.00 47.50 CG5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 47.50 CD3AXA04800012.00 48.00 CD3AXA06000012.00 47.50 CD3BXA04800012.00 48.00 CD3BXA06000012.10 48.00 CD3CXA06000012.00 47.50 CE3AXA04800012.50 48.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 40: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/40.jpg)
38TRA06031 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.50 11.50 57.00 FA4ANB06000011.50 11.50 57.00 FA4ANF06000011.50 11.50 57.00 FB4ANB06000012.00 12.00 58.00 FB4ANB07000011.50 11.50 57.00 FB4ANF06000012.20 58.00 FC4BNB05400011.50 57.00 FC4BNB06000012.00 58.00 FC4BNB07000011.50 57.00 FC4BNF060000
12.00 57.00 FG3AAA06000012.50 58.00 FK4BNB00600012.50 58.00 FK4CNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1401HSO
TXV (RPB)KAATX0701RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 55.00 CC5AXA06000012.00 57.00 CC5AXW06000012.00 55.00 CD5AXA06000012.00 57.00 CD5AXW06000012.00 55.00 CD5BXA06000012.00 57.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 55.00 CD3AXA06000012.00 55.00 CD3BXA06000012.00 56.00 CD3CXA07000012.00 57.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 41: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/41.jpg)
38TUA01830 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.50 10.50 17.20 FA4ANF018000
11.00 11.00 17.80 FA4ANF024000
10.50 10.50 17.20 FB4ANF018000
11.00 11.00 17.80 FB4ANF024000
11.00 17.80 FC4BNF024000
11.00 18.00 FC4BNF033000
10.00 10.20 17.50 FD3ANA018000
10.50 17.80 FD3ANA024000
11.00 11.00 17.40 FF1ANA018000
11.00 11.00 17.80 FF1ANA024000
11.00 11.00 17.40 FF1BNA018000
11.00 11.00 17.80 FF1BNA024000
10.40 10.70 17.60 FG3AAA024000
12.50 18.50 FK4BNF001000
12.70 18.50 FK4BNF002000
13.00 18.50 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX0901HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0201RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.20 10.50 17.40 CC5AXA018000
10.50 11.00 17.80 CC5AXA024000
10.50 11.00 17.80 CC5AXW024000
10.20 10.50 17.40 CD5AXA018000
10.50 11.00 17.80 CD5AXA024000
10.50 11.00 17.80 CD5AXW024000
10.20 10.50 17.40 CD5BXA018000
10.50 11.00 17.80 CD5BXA024000
10.50 11.00 17.80 CD5BXW024000
10.50 11.00 17.80 CF5AXA024000
10.50 11.00 17.80 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 10.50 17.40 CD3AXA018000
10.50 11.00 17.80 CD3AXA024000
10.20 10.50 17.40 CD3BXA018000
10.50 11.00 17.80 CD3BXA024000
10.50 11.00 17.80 CD3CXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 42: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/42.jpg)
38TUA02430 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 23.40 FA4ANF024000
11.50 11.50 23.80 FA4ANF030000
11.00 11.00 23.40 FB4ANF024000
11.50 11.50 23.80 FB4ANF030000
11.10 23.60 FC4BNF024000
11.50 23.80 FC4BNF030000
11.50 24.20 FC4BNF033000
11.00 11.20 23.20 FD3ANA024000
11.00 11.30 23.80 FD3ANA030000
11.00 11.00 23.40 FF1ANA024000
11.30 11.30 24.00 FF1ANA030000
11.00 11.00 23.40 FF1BNA024000
11.30 11.30 24.00 FF1BNA030000
10.70 11.00 23.20 FG3AAA024000
12.50 24.80 FK4BNF001000
12.60 25.00 FK4BNF002000
13.00 25.00 FK4BNF003000
13.00 25.00 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG,
Command Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR,Home Access Module ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN,Fuse Pack ZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0301RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 11.00 23.40 CC5AXA024000
10.70 11.00 23.60 CC5AXA030000
10.50 11.00 23.40 CC5AXW024000
10.70 11.00 23.40 CC5AXW030000
10.50 11.00 23.40 CD5AXA024000
10.70 11.00 23.60 CD5AXA030000
10.50 11.00 23.40 CD5AXW024000
10.70 11.00 23.40 CD5AXW030000
10.50 11.00 23.40 CD5BXA024000
10.70 11.00 23.60 CD5BXA030000
10.50 11.00 23.40 CD5BXW024000
10.70 11.00 23.40 CD5BXW030000
10.70 11.00 23.40 CF5AXA024000
10.70 11.00 23.40 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 11.00 23.40 CD3AXA024000
10.70 11.00 23.40 CD3AXA030000
10.50 11.00 23.40 CD3BXA024000
10.70 11.00 23.40 CD3BXA030000
10.70 11.00 23.40 CD3CXA024000
10.70 11.00 23.40 CD3CXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 43: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/43.jpg)
38TUA03030 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 27.80 FA4ANF030000
10.70 10.70 28.60 FA4ANF036000
11.00 11.00 27.80 FB4ANF030000
10.70 10.70 28.60 FB4ANF036000
10.80 28.00 FC4BNF030000
11.00 29.00 FC4BNF033000
10.70 28.80 FC4BNF036000
10.20 10.50 28.20 FD3ANA030000
10.80 10.80 28.20 FF1ANA030000
10.80 10.80 28.20 FF1BNA030000
10.50 11.00 28.80 FG3AAA036000
11.50 28.20 FK4BNF001000
11.50 28.60 FK4BNF002000
12.00 29.20 FK4BNF003000
12.00 29.20 FK4BNF004000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
CarrierWeathermaker Two
ZoneZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0601SML
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0401RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.20 10.50 28.00 CC5AXA030000
10.70 11.00 29.00 CC5AXA036000
10.20 10.50 28.00 CC5AXW030000
10.20 10.50 28.00 CD5AXA030000
10.70 11.00 29.00 CD5AXA036000
10.20 10.50 28.00 CD5AXW030000
10.50 11.00 29.00 CD5AXW036000
10.20 10.50 28.00 CD5BXA030000
10.70 11.00 29.00 CD5BXA036000
10.20 10.50 28.00 CD5BXW030000
10.50 11.00 29.00 CD5BXW036000
10.50 11.00 28.80 CF5AXA036000
10.50 11.00 28.80 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 10.50 28.00 CD3AXA030000
10.70 11.00 29.00 CD3AXA036000
10.20 10.50 28.00 CD3BXA030000
10.70 11.00 29.00 CD3BXA036000
10.20 10.50 28.00 CD3CXA030000
10.40 10.70 28.40 CD3CXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 44: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/44.jpg)
38TUA03630 (77 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 34.80 FA4ANB042000
10.80 10.80 34.20 FA4ANF036000
11.00 11.00 34.80 FA4ANF042000
11.00 11.00 34.80 FB4ANB042000
10.80 10.80 34.20 FB4ANF036000
11.00 11.00 34.80 FB4ANF042000
11.00 34.80 FC4BNB042000
11.80 36.60 FC4BNB054000
11.00 34.80 FC4BNF033000
10.80 34.20 FC4BNF036000
11.30 36.00 FC4BNF038000
11.00 34.80 FC4BNF042000
10.70 11.00 34.20 FG3AAA036000
13.00 36.00 FK4BNB006000
11.20 34.00 FK4BNF001000
11.20 34.40 FK4BNF002000
12.00 34.80 FK4BNF003000
12.00 34.60 FK4BNF004000
12.50 36.00 FK4BNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8083S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 11.20 34.80 CC5AXA036000
11.00 11.20 35.00 CC5AXA042000
10.70 11.00 34.60 CC5AXW042000
11.00 11.20 34.80 CD5AXA036000
11.00 11.20 35.00 CD5AXA042000
11.00 11.20 34.80 CD5AXW036000
10.70 11.00 34.60 CD5AXW042000
11.00 11.20 34.80 CD5BXA036000
11.00 11.20 35.00 CD5BXA042000
11.00 11.20 34.80 CD5BXW036000
10.70 11.00 34.60 CD5BXW042000
11.00 11.20 34.60 CF5AXA036000
11.00 11.20 34.60 CG5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 11.20 34.80 CD3AXA036000
11.00 11.20 34.80 CD3AXA042000
11.00 11.20 34.80 CD3BXA036000
11.00 11.20 34.80 CD3BXA042000
10.70 11.00 34.40 CD3CXA036000
10.70 11.00 34.40 CD3CXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 45: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/45.jpg)
38TUA04230 (77 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 40.50 FA4ANB042000
11.10 11.10 41.50 FA4ANB048000
11.00 11.00 40.50 FA4ANF042000
11.10 11.10 41.50 FA4ANF048000
11.00 11.00 40.50 FB4ANB042000
11.10 11.10 41.50 FB4ANB048000
11.00 11.00 40.50 FB4ANF042000
11.10 11.10 41.50 FB4ANF048000
11.00 40.50 FC4BNB042000
11.00 41.00 FC4BNB048000
11.50 42.50 FC4BNB054000
11.00 40.50 FC4BNF042000
11.00 41.00 FC4BNF048000
10.70 11.00 41.00 FG3AAA048000
12.20 42.50 FK4BNB005000
12.50 42.50 FK4BNB006000
12.00 41.00 FK4BNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.70 11.00 41.00 CC5AXA042000
10.70 11.00 40.50 CC5AXC048000
10.70 11.00 40.50 CC5AXW042000
10.70 11.00 41.00 CC5AXW048000
10.70 11.00 41.00 CD5AXA042000
10.70 11.00 41.00 CD5AXA048000
10.70 11.00 40.50 CD5AXC048000
10.70 11.00 40.50 CD5AXW042000
10.70 11.00 41.00 CD5AXW048000
10.70 11.00 41.00 CD5BXA042000
10.70 11.00 41.00 CD5BXA048000
10.70 11.00 40.50 CD5BXC048000
10.70 11.00 40.50 CD5BXW042000
10.70 11.00 41.00 CD5BXW048000
10.70 11.00 41.00 CF5AXA048000
10.70 11.00 41.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.70 11.00 41.00 CD3AXA042000
10.70 11.00 41.00 CD3AXA048000
10.70 11.00 41.00 CD3BXA042000
10.70 11.00 41.00 CD3BXA048000
10.50 10.70 39.50 CD3CXA042000
10.70 11.00 40.50 CD3CXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 46: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/46.jpg)
38TUA04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.00 11.00 46.50 FA4ANB048000
11.00 11.00 48.00 FA4ANB060000
11.00 11.00 46.50 FA4ANF048000
11.00 11.00 48.00 FA4ANF060000
11.00 11.00 46.50 FB4ANB048000
11.00 11.00 48.00 FB4ANB060000
11.50 11.50 48.00 FB4ANB070000
11.00 11.00 46.50 FB4ANF048000
11.00 11.00 48.00 FB4ANF060000
11.00 47.00 FC4BNB048000
11.50 48.00 FC4BNB054000
11.00 48.00 FC4BNB060000
11.50 48.00 FC4BNB070000
11.00 47.00 FC4BNF048000
11.00 48.00 FC4BNF060000
10.50 10.80 48.00 FG3AAA048000
10.70 11.00 48.00 FG3AAA060000
12.50 48.50 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0801AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0801AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0601RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.60 11.00 47.00 CC5AXA060000
10.50 10.80 45.00 CC5AXC048000
10.50 11.00 46.00 CC5AXW048000
10.80 11.20 48.00 CC5AXW060000
10.50 11.00 46.50 CD5AXA048000
10.60 11.00 47.00 CD5AXA060000
10.50 10.80 45.00 CD5AXC048000
10.50 11.00 46.00 CD5AXW048000
10.80 11.20 48.00 CD5AXW060000
10.50 11.00 46.50 CD5BXA048000
10.60 11.00 47.00 CD5BXA060000
10.50 10.80 45.00 CD5BXC048000
10.50 11.00 46.00 CD5BXW048000
10.80 11.20 48.00 CD5BXW060000
10.70 11.20 47.00 CF5AXA048000
10.70 11.20 47.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 11.00 46.50 CD3AXA048000
10.60 11.00 47.00 CD3AXA060000
10.50 11.00 46.50 CD3BXA048000
10.60 11.00 47.00 CD3BXA060000
10.30 10.80 46.50 CD3CXA048000
10.50 11.00 47.00 CD3CXA060000
10.70 11.00 46.50 CE3AXA048000
11.00 11.20 48.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 47: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/47.jpg)
38TUA06030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.70 10.70 58.00 FA4ANB060000
10.70 10.70 58.00 FA4ANF060000
10.70 10.70 58.00 FB4ANB060000
11.00 11.00 59.00 FB4ANB070000
10.70 10.70 58.00 FB4ANF060000
11.30 58.00 FC4BNB054000
10.70 57.50 FC4BNB060000
11.00 59.00 FC4BNB070000
10.70 57.50 FC4BNF060000
10.70 11.00 57.00 FG3AAA060000
11.70 58.50 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP502-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorStandard
Fan Control CenterP211-4013
Filter DrierP502-8163S
High-Pressure SwitchKSAHI0101HPS
Low-Pressure SwitchKAALP0101LPS
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (RPB)KAATX0701RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.60 11.00 55.00 CC5AXA060000
10.80 11.00 57.00 CC5AXW060000
10.60 11.00 55.00 CD5AXA060000
10.80 11.00 57.00 CD5AXW060000
10.60 11.00 55.00 CD5BXA060000
10.80 11.00 57.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.60 11.00 55.00 CD3AXA060000
10.60 11.00 55.00 CD3BXA060000
10.50 11.00 57.00 CD3CXA060000
10.50 11.00 57.50 CD3CXA070000
10.80 11.20 58.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 48: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/48.jpg)
38TXA02430 (70 dBA)
FAN COILS12.50 12.50 24.00 FA4ANF024000
13.00 13.00 24.00 FA4ANF030000
12.50 12.50 24.00 FB4ANF024000
13.00 13.00 24.00 FB4ANF030000
12.50 12.50 24.00 FD3ANA024000
12.50 12.50 24.00 FD3ANA030000
12.50 12.50 24.00 FF1ANA024000
13.00 13.00 24.00 FF1ANA030000
12.50 12.50 24.00 FF1BNA024000
13.00 13.00 24.00 FF1BNA030000
12.00 24.00 FG3ANA024000
14.00 26.00 FK4CNF002000
14.00 28.00 FK4CNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable
TSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0201LLS
TDRKAATD0101TDR
TXV (HSO)KAATX1901HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierKH45LG140
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing Fan MotorHC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-Ambient ControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierKH45LG140
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX1901HSO
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB (15 FT )P850-30610-06PEB (20 FT )P850-40610-06PEB (25 FT )P850-50610-06PEB (30 FT )P850-60610-06PEB (35 FT )P850-70610-06PEB (40 FT )P850-90610-06PEB (50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.50 24.00 CC5AXA024000
13.00 24.00 CC5AXA030000
12.50 24.00 CC5AXW024000
13.00 24.00 CC5AXW030000
12.50 24.00 CD5AXA024000
13.00 24.00 CD5AXA030000
12.50 24.00 CD5AXW024000
13.00 24.00 CD5AXW030000
12.50 24.00 CD5BXA024000
13.00 24.00 CD5BXA030000
12.50 24.00 CD5BXW024000
13.00 24.00 CD5BXW030000
12.50 24.00 CF5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.50 24.00 CD3AXA024000
13.00 24.00 CD3AXA030000
12.50 24.00 CD3BXA024000
13.00 24.00 CD3BXA030000
12.50 24.00 CD3CXA024000
12.50 24.00 CD3CXA030000
12.50 24.00 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 49: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/49.jpg)
38TXA03030 (71 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.50 12.50 28.60 FA4ANF030000
12.50 12.50 29.00 FA4ANF036000
12.50 12.50 28.60 FB4ANF030000
12.50 12.50 29.00 FB4ANF036000
12.20 12.20 28.00 FD3ANA030000
12.50 12.50 28.60 FF1ANA030000
12.50 12.50 28.60 FF1BNA030000
12.50 28.40 FG3AAA036000
13.00 29.00 FK4CNF001000
13.50 29.00 FK4CNF002000
14.00 29.60 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0201LLS
TDRKAATD0101TDR
TXV (HSO)KAATX2001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierKH45LG140
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierKH45LG140
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX2001HSO
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.50 28.00 CC5AXA030000
13.00 29.00 CC5AXA036000
12.50 28.00 CC5AXW030000
12.50 28.00 CD5AXA030000
13.00 29.00 CD5AXA036000
12.50 28.00 CD5AXW030000
13.00 29.00 CD5AXW036000
12.50 28.00 CD5BXA030000
13.00 29.00 CD5BXA036000
12.50 28.00 CD5BXW030000
13.00 29.00 CD5BXW036000
12.50 28.40 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.50 28.00 CD3AXA030000
13.00 29.00 CD3AXA036000
12.50 28.00 CD3BXA030000
13.00 29.00 CD3BXA036000
12.20 27.60 CD3CXA030000
12.20 28.00 CD3CXA036000
12.50 28.00 CE3AXA030000
12.50 28.40 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 50: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/50.jpg)
38TXA03630 (71 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS13.00 13.00 35.00 FA4ANB04200012.50 12.50 35.00 FA4ANF03600013.00 13.00 35.00 FA4ANF04200013.00 13.00 35.00 FB4ANB04200012.50 12.50 35.00 FB4ANF03600013.00 13.00 35.00 FB4ANF042000
12.20 35.00 FG3AAA03600014.00 36.00 FK4CNB00600013.00 35.00 FK4CNF00200013.50 35.00 FK4CNF003000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG,
Command Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR,Home Access Module ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN,Fuse Pack ZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
RectangularDampers
8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0201LLS
TDRKAATD0101TDR
TXV (HSO)KAATX2101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierKH45LG140
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierKH45LG140
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX2101HSO
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow13.00 35.00 CC5AXA03600013.00 35.00 CC5AXA04200012.50 35.00 CC5AXW04200013.00 35.00 CD5AXA03600013.00 35.00 CD5AXA04200013.00 35.00 CD5AXW03600012.50 35.00 CD5AXW04200013.00 35.00 CD5BXA03600013.00 35.00 CD5BXA04200013.00 35.00 CD5BXW03600012.50 35.00 CD5BXW04200013.00 35.00 CF5AXA036000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.00 35.00 CD3AXA03600013.00 35.00 CD3AXA04200013.00 35.00 CD3BXA03600013.00 35.00 CD3BXA04200012.20 34.00 CD3CXA03600012.20 34.00 CD3CXA04200012.50 35.00 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 51: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/51.jpg)
38TXA04230 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.50 12.50 40.50 FA4ANB04200013.00 13.00 41.00 FA4ANB04800012.50 12.50 40.50 FA4ANF04200013.00 13.00 41.00 FA4ANF04800012.50 12.50 40.50 FB4ANB04200013.00 13.00 41.00 FB4ANB04800012.50 12.50 40.50 FB4ANF04200013.00 13.00 41.00 FB4ANF048000
12.50 40.00 FG3AAA04800014.00 41.50 FK4CNB00600013.00 39.50 FK4CNF00300013.50 41.00 FK4CNF005000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG,
Command Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR,Home Access Module ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN,Fuse Pack ZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0201LLS
TDRKAATD0101TDR
TXV (HSO)KAATX2201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierKH45LG140
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierKH45LG141
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX2201HSO
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow13.00 40.50 CC5AXA04200012.50 40.00 CC5AXC04800012.50 40.00 CC5AXW04200013.00 40.50 CC5AXW04800013.00 40.50 CD5AXA04200013.00 40.50 CD5AXA04800012.50 40.00 CD5AXC04800012.50 40.00 CD5AXW04200013.00 40.50 CD5AXW04800013.00 40.50 CD5BXA04200013.00 40.50 CD5BXA04800012.50 40.00 CD5BXC04800012.50 40.00 CD5BXW04200013.00 40.50 CD5BXW04800012.50 40.50 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.00 40.50 CD3AXA04200013.00 40.50 CD3AXA04800013.00 40.50 CD3BXA04200013.00 40.50 CD3BXA04800012.20 38.50 CD3CXA04200012.20 39.50 CD3CXA04800013.00 41.00 CE3AXA04200013.00 41.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 52: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/52.jpg)
38TXA04830 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.20 12.20 46.00 FA4ANB04800012.50 12.50 47.00 FA4ANB06000012.20 12.20 46.00 FA4ANF04800012.50 12.50 47.00 FA4ANF06000012.20 12.20 46.00 FB4ANB04800012.50 12.50 47.00 FB4ANB06000013.00 13.00 47.50 FB4ANB07000012.20 12.20 46.00 FB4ANF04800012.50 12.50 47.00 FB4ANF060000
12.20 46.00 FG3AAA04800012.50 46.50 FG3AAA06000014.00 47.50 FK4BNB006000
ComfortVentilator
VA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
EnergyRecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Dependingon application, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command
Center ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home AccessModule ZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse PackZONEFUSEPACK, Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorConnector BoardZONESMSENCBD
Smart SensorZONESMSENCAR
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPAC01-A
Auto ChangeoverNon-ProgrammableTSTATCCNAC01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable
TSTATTSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-213
Outdoor SensorTSTATCCSEN01
LLSKAALS0201LLS
TDRKAATD0101TDR
TXV (HSO)KAATX2301HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierKH45LG140
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0801AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Low-AmbientControllerP251-0083
MotorMaster9
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0801AAA
Winter Start ControlKAAWS0101AAA
Coastal FilterKAACF0201MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Fan Control CenterP211-4013
Filter DrierKH45LG141
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Sound BlanketStandard
Support FeetKSASF0101AAA
TXV (HSO)KAATX2301HSO
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow13.00 46.50 CC5AXA06000012.50 45.00 CC5AXC04800013.00 46.00 CC5AXW04800013.00 47.00 CC5AXW06000013.00 46.00 CD5AXA04800013.00 46.50 CD5AXA06000012.50 45.00 CD5AXC04800013.00 46.00 CD5AXW04800013.00 47.00 CD5AXW06000013.00 46.00 CD5BXA04800013.00 46.50 CD5BXA06000012.50 45.00 CD5BXC04800013.00 46.00 CD5BXW04800013.00 47.00 CD5BXW06000012.50 46.00 CF5AXA048000
Furnan Blk 2Upflow
58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.00 46.00 CD3AXA04800013.00 46.50 CD3AXA06000013.00 46.00 CD3BXA04800013.00 46.50 CD3BXA06000012.20 45.00 CD3CXA04800012.20 46.00 CD3CXA06000012.50 46.00 CD3CXA07000013.00 46.50 CE3AXA04800013.00 47.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SETSEER
SEER WITHENHANCEMENT1
CAPACITYMBTUH
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
![Page 53: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/53.jpg)
38AYB01830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.50 10.50 7.00 16.50 17.30 FA4ANF018000
11.00 11.00 7.40 17.00 18.00 FA4ANF024000
10.50 10.50 7.00 16.50 17.30 FB4ANF018000
11.00 11.00 7.40 17.00 18.00 FB4ANF024000
11.00 7.20 17.00 18.00 FC4BNF024000
10.70 7.00 16.60 18.00 FD3ANA018000
10.20 11.00 7.20 16.70 18.00 FD3ANA024000
10.00 10.50 7.00 16.40 17.40 FF1ANA018000
10.20 11.00 7.40 16.90 18.00 FF1ANA024000
10.00 10.50 7.00 16.40 17.40 FF1BNA018000
10.20 11.00 7.40 16.90 18.00 FF1BNA024000
10.00 11.00 7.20 16.80 18.00 FG3AAA024000
12.10 7.90 16.60 18.00 FK4BNF001000
12.10 8.00 16.60 18.00 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCStandard
Start CapacitorKSAHS0701AAA
Ball Bearing FanMotor
HD34GE231
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCStandard
Start CapacitorKSAHS0701AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1501BRL
TXV (RPB)KHATX0201RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 7.00 16.30 18.00 CC5AXA018000
10.00 11.00 7.20 16.70 18.00 CC5AXA024000
10.50 7.00 16.30 18.00 CD5AXA018000
10.00 11.00 7.20 16.70 18.00 CD5AXA024000
10.50 7.00 16.30 18.00 CD5BXA018000
10.00 11.00 7.20 16.70 18.00 CD5BXA024000
10.10 11.00 7.20 16.80 18.00 CF5AXA024000
11.00 11.00 7.20 16.80 18.00 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 7.00 16.30 18.00 CD3AXA018000
10.00 11.00 7.20 16.70 18.00 CD3AXA024000
10.50 7.00 16.30 18.00 CD3BXA018000
10.00 11.00 7.20 16.70 18.00 CD3BXA024000
11.00 7.40 16.90 18.00 CD3CXA024000
10.00 11.00 7.20 16.80 18.00 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 54: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/54.jpg)
38AYB02430 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.20 23.60 22.60 FA4ANF024000
11.00 11.00 7.50 23.60 23.00 FB4ANA030000
11.00 11.00 7.20 23.60 22.60 FB4ANF024000
11.00 11.00 7.50 23.60 23.00 FB4ANF030000
11.50 7.50 23.60 22.60 FC4BNF024000
11.50 7.50 23.60 23.00 FC4BNF030000
10.50 7.40 23.60 22.20 FD3ANA024000
11.00 7.50 23.60 23.20 FD3ANA030000
10.50 10.50 7.50 23.60 22.60 FF1ANA024000
11.00 11.00 7.50 23.60 23.20 FF1ANA030000
10.50 10.50 7.50 23.60 22.60 FF1BNA024000
11.00 11.00 7.50 23.60 23.20 FF1BNA030000
10.50 7.35 23.60 22.20 FG3AAA024000
12.50 7.80 23.60 23.20 FK4BNF001000
12.50 7.80 23.60 23.40 FK4BNF002000
12.50 8.00 23.80 23.80 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1801COP
TXV (RPB)KHATX0301RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 7.30 23.60 22.40 CC5AXA024000
11.00 7.30 23.60 22.60 CC5AXA030000
11.00 7.30 23.60 22.60 CC5AXW030000
10.50 7.30 23.60 22.40 CD5AXA024000
11.00 7.30 23.60 22.60 CD5AXA030000
11.00 7.30 23.60 22.60 CD5AXW030000
10.50 7.30 23.60 22.40 CD5BXA024000
11.00 7.30 23.60 22.60 CD5BXA030000
11.00 7.30 23.60 22.60 CD5BXW030000
11.00 7.30 23.60 22.60 CF5AXA024000
11.00 11.00 7.30 23.60 22.60 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 7.30 23.60 22.40 CD3AXA024000
11.00 7.30 23.60 22.60 CD3AXA030000
10.50 7.30 23.60 22.40 CD3BXA024000
11.00 7.30 23.60 22.60 CD3BXA030000
10.50 7.35 23.60 22.40 CD3CXA024000
10.50 7.35 23.60 22.40 CD3CXA030000
11.00 7.35 23.60 22.40 CD3CXA036000
10.50 7.30 23.60 22.60 CE3AXA024000
11.00 7.50 23.60 23.00 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 55: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/55.jpg)
38AYB03030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.60 29.60 28.40 FA4ANF030000
11.00 11.00 7.60 29.60 28.40 FA4ANF036000
11.00 11.00 7.60 29.60 28.40 FB4ANF030000
11.00 11.00 7.60 29.60 28.40 FB4ANF036000
11.50 7.60 29.60 28.00 FC4BNF030000
11.50 7.60 29.60 28.40 FC4BNF036000
11.00 7.50 29.60 28.20 FD3ANA030000
11.00 11.00 7.50 29.40 28.20 FF1ANA030000
11.00 11.00 7.50 29.40 28.20 FF1BNA030000
11.00 7.50 29.40 28.40 FG3AAA036000
12.00 7.90 29.20 28.60 FK4BNF001000
12.00 8.00 29.20 28.60 FK4BNF002000
12.00 8.00 28.80 29.00 FK4BNF003000
2.00 8.00 29.20 29.20 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1801COP
TXV (RPB)KHATX0401RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 7.30 29.00 27.80 CC5AXA030000
11.00 7.50 29.40 28.80 CC5AXA036000
11.00 7.30 29.00 27.80 CC5AXW030000
11.00 7.30 29.00 27.80 CD5AXA030000
11.00 7.50 29.40 28.80 CD5AXA036000
11.00 7.30 29.00 27.80 CD5AXW030000
11.00 7.50 29.40 28.80 CD5AXW036000
11.00 7.30 29.00 27.80 CD5BXA030000
11.00 7.50 29.40 28.80 CD5BXA036000
11.00 7.30 29.00 27.80 CD5BXW030000
11.00 7.50 29.40 28.80 CD5BXW036000
11.00 7.50 29.40 28.40 CF5AXA036000
11.00 11.00 7.50 29.40 28.40 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 7.30 29.00 27.80 CD3AXA030000
11.00 7.50 29.40 28.80 CD3AXA036000
11.00 7.30 29.00 27.80 CD3BXA030000
11.00 7.50 29.40 28.80 CD3BXA036000
11.00 7.50 29.60 27.40 CD3CXA030000
11.00 7.60 29.60 28.00 CD3CXA036000
11.00 7.50 29.40 28.00 CE3AXA030000
11.00 7.50 29.40 28.40 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 56: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/56.jpg)
38AYB03630 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.50 11.50 8.00 35.80 33.80 FA4ANB042000
11.00 11.00 7.60 36.00 33.20 FA4ANF036000
11.50 11.50 8.00 35.80 33.80 FA4ANF042000
11.50 11.50 8.00 35.80 33.80 FB4ANB042000
11.00 11.00 7.60 36.00 33.20 FB4ANF036000
11.50 11.50 8.00 35.80 33.80 FB4ANF042000
11.50 8.00 35.80 33.80 FC4BNB042000
11.00 7.60 36.00 33.00 FC4BNF036000
11.50 8.00 35.80 33.80 FC4BNF042000
11.50 7.70 35.80 33.00 FG3AAA036000
12.00 8.30 35.60 35.20 FK4BNB005000
11.50 8.00 35.40 33.00 FK4BNF002000
12.00 8.10 35.20 34.00 FK4BNF003000
12.00 8.20 35.40 33.60 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH0601COP
TXV (RPB)KHATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 7.70 35.80 33.60 CC5AXA036000
11.50 7.70 35.80 33.60 CC5AXA042000
11.50 7.60 35.80 33.40 CC5AXW042000
11.50 7.70 35.80 33.60 CD5AXA036000
11.50 7.70 35.80 33.60 CD5AXA042000
11.50 7.70 35.80 33.60 CD5AXW036000
11.50 7.60 35.80 33.40 CD5AXW042000
11.50 7.70 35.80 33.60 CD5BXA036000
11.50 7.70 35.80 33.60 CD5BXA042000
11.50 7.70 35.80 33.60 CD5BXW036000
11.50 7.60 35.80 33.40 CD5BXW042000
11.50 7.70 35.80 33.40 CF5AXA036000
11.50 11.50 7.70 35.80 33.40 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.50 7.70 35.80 33.60 CD3AXA036000
11.50 7.70 35.80 33.60 CD3AXA042000
11.50 7.70 35.80 33.60 CD3BXA036000
11.50 7.70 35.80 33.60 CD3BXA042000
11.00 7.50 35.60 32.40 CD3CXA036000
11.00 7.50 35.60 32.40 CD3CXA042000
11.30 7.70 36.00 33.20 CD3CXA048000
11.50 7.60 35.60 33.20 CE3AXA036000
11.50 7.70 36.00 33.80 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 57: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/57.jpg)
38AYB04230 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.60 42.50 39.50 FA4ANB042000
11.00 11.00 8.00 43.00 40.00 FA4ANB048000
11.00 11.00 7.60 42.50 39.50 FA4ANF042000
11.00 11.00 8.00 43.00 40.00 FA4ANF048000
11.00 11.00 7.60 42.50 39.50 FB4ANB042000
11.00 11.00 8.00 43.00 40.00 FB4ANB048000
11.00 11.00 7.60 42.50 39.50 FB4ANF042000
11.00 11.00 8.00 43.00 40.00 FB4ANF048000
11.00 7.60 42.50 39.50 FC4BNB042000
11.50 8.00 43.00 40.00 FC4BNB048000
11.00 7.60 42.50 39.50 FC4BNF042000
11.50 8.00 43.00 40.00 FC4BNF048000
11.00 7.70 42.50 39.50 FG3AAA048000
12.00 8.30 42.50 41.50 FK4BNB005000
11.30 7.90 41.50 39.50 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH0601COP
TXV (RPB)KHATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 7.50 42.00 39.00 CC5AXA042000
11.00 7.50 42.00 39.00 CC5AXC048000
11.00 7.50 43.50 39.00 CC5AXW042000
11.00 7.60 42.50 40.00 CC5AXW048000
11.00 7.50 42.00 39.00 CD5AXA042000
11.00 7.60 42.50 40.00 CD5AXA048000
11.00 7.50 42.00 39.00 CD5AXC048000
11.00 7.50 43.50 39.00 CD5AXW042000
11.00 7.60 42.50 40.00 CD5AXW048000
11.00 7.50 42.00 39.00 CD5BXA042000
11.00 7.60 42.50 40.00 CD5BXA048000
11.00 7.50 42.00 39.00 CD5BXC048000
11.00 7.50 43.50 39.00 CD5BXW042000
11.00 7.60 42.50 40.00 CD5BXW048000
11.00 7.60 42.00 40.00 CF5AXA048000
11.00 11.00 7.60 42.00 40.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 7.50 42.00 39.00 CD3AXA042000
11.00 7.60 42.50 40.00 CD3AXA048000
11.00 7.50 42.00 39.00 CD3BXA042000
11.00 7.60 42.50 40.00 CD3BXA048000
10.70 7.50 42.00 37.80 CD3CXA042000
11.00 7.70 42.50 39.00 CD3CXA048000
11.00 7.60 42.50 39.50 CE3AXA042000
11.00 7.70 42.50 40.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 58: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/58.jpg)
38AYB04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.60 48.00 45.50 FA4ANB048000
11.00 11.00 7.70 48.00 47.00 FA4ANB060000
11.00 11.00 7.60 48.00 45.50 FA4ANF048000
11.00 11.00 7.70 48.00 47.00 FA4ANF060000
11.00 11.00 7.60 48.00 45.50 FB4ANB048000
11.00 11.00 7.70 48.00 47.00 FB4ANB060000
11.50 11.50 8.00 48.00 48.00 FB4ANB070000
11.00 11.00 7.60 48.00 45.50 FB4ANF048000
11.00 11.00 7.70 48.00 47.00 FB4ANF060000
11.00 7.60 48.00 45.50 FC4BNB048000
11.00 7.70 48.00 46.50 FC4BNB060000
11.50 8.00 48.00 48.00 FC4BNB070000
11.00 7.60 48.00 45.50 FC4BNF048000
11.00 7.70 48.00 46.50 FC4BNF060000
11.00 7.50 48.00 45.00 FG3AAA048000
11.00 7.70 48.00 46.00 FG3AAA060000
12.00 8.00 48.00 47.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1701COP
TXV (RPB)KHATX0601RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 7.30 48.00 45.00 CC5AXA060000
11.00 7.00 48.00 44.00 CC5AXC048000
11.00 7.40 48.00 44.50 CC5AXW048000
11.00 7.70 48.00 46.50 CC5AXW060000
11.00 7.40 48.00 44.50 CD5AXA048000
11.00 7.30 48.00 45.00 CD5AXA060000
11.00 7.00 48.00 44.00 CD5AXC048000
11.00 7.40 48.00 44.50 CD5AXW048000
11.00 7.70 48.00 46.50 CD5AXW060000
11.00 7.40 48.00 44.50 CD5BXA048000
11.00 7.30 48.00 45.00 CD5BXA060000
11.00 7.00 48.00 44.00 CD5BXC048000
11.00 7.40 48.00 44.50 CD5BXW048000
11.00 7.70 48.00 46.50 CD5BXW060000
11.00 7.30 48.00 45.00 CF5AXA048000
11.00 11.00 7.30 48.00 45.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 7.40 48.00 44.50 CD3AXA048000
11.00 7.30 48.00 45.00 CD3AXA060000
11.00 7.40 48.00 44.50 CD3BXA048000
11.00 7.30 48.00 45.00 CD3BXA060000
10.80 7.40 48.00 44.00 CD3CXA048000
11.00 7.50 48.50 45.50 CD3CXA060000
11.10 7.70 48.50 46.00 CD3CXA070000
11.00 7.50 48.00 45.00 CE3AXA048000
11.50 7.70 48.00 46.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 59: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/59.jpg)
38AYB06030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.30 60.50 54.00 FA4ANB060000
11.00 11.00 7.30 60.50 54.00 FA4ANF060000
11.00 11.00 7.30 60.50 54.00 FB4ANB060000
11.00 11.00 7.50 60.50 55.50 FB4ANB070000
11.00 11.00 7.30 60.50 54.00 FB4ANF060000
11.00 7.30 60.50 54.00 FC4BNB060000
11.00 7.50 60.50 55.00 FC4BNB070000
11.00 7.30 60.50 54.00 FC4BNF060000
11.00 7.20 59.50 53.00 FG3AAA060000
11.50 7.80 60.00 55.50 FK4ANF006000
11.50 7.80 60.00 55.50 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1401HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High Pressure SwitchKSAHI0201HPS
Low Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1701COP
TXV (RPB)KHATX0701RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 6.80 58.50 52.00 CC5AXA060000
11.00 7.10 59.50 53.50 CC5AXW060000
11.00 6.80 58.50 52.00 CD5AXA060000
11.00 7.10 59.50 53.50 CD5AXW060000
11.00 6.80 58.50 52.00 CD5BXA060000
11.00 7.10 59.50 53.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 6.80 58.50 52.00 CD3AXA060000
11.00 6.80 58.50 52.00 CD3BXA060000
11.00 7.20 60.00 52.00 CD3CXA060000
11.00 7.20 60.00 53.00 CD3CXA070000
11.00 7.20 59.50 54.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 60: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/60.jpg)
38BYB01830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.00 7.50 16.60 18.70 FA4ANA024000
11.30 7.00 16.10 17.40 FA4ANF018000
12.00 7.50 16.60 18.70 FA4ANF024000
12.00 7.50 16.60 18.70 FB4ANA024000
11.30 7.00 16.10 17.40 FB4ANF018000
12.00 7.50 16.60 18.70 FB4ANF024000
12.00 7.50 16.60 18.80 FC4BNF024000
11.50 7.00 16.20 17.80 FD3ANA018000
12.00 7.50 16.30 18.40 FD3ANA024000
11.50 7.00 16.00 17.60 FF1ANA018000
12.00 7.50 16.50 18.80 FF1ANA024000
11.50 7.00 16.00 17.60 FF1BNA018000
12.00 7.50 16.50 18.80 FF1BNA024000
11.50 7.50 16.40 18.40 FG3AAA024000
13.20 8.00 16.00 18.80 FK4BNF001000
13.20 8.00 16.10 19.40 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCN/A
Start CapacitorStandard
Ball Bearing FanMotor
HC34GE231
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCN/A
Start CapacitorStandard
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1501BRL
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 7.00 16.00 17.80 CC5AXA018000
11.50 7.20 16.30 18.50 CC5AXA024000
11.50 7.00 16.00 17.80 CD5AXA018000
11.50 7.20 16.30 18.50 CD5AXA024000
11.50 7.00 16.00 17.80 CD5BXA018000
11.50 7.20 16.30 18.50 CD5BXA024000
12.00 7.20 16.40 18.50 CF5AXA024000
11.50 12.00 7.20 16.40 18.50 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.50 7.00 16.00 17.80 CD3AXA018000
11.50 7.20 16.30 18.50 CD3AXA024000
11.50 7.00 16.00 17.80 CD3BXA018000
11.50 7.20 16.30 18.50 CD3BXA024000
11.70 12.00 7.40 16.20 18.50 CD3CXA024000
12.00 7.20 16.40 18.50 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 61: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/61.jpg)
38BYB02430 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.70 7.50 23.60 22.60 FA4ANA024000
12.00 7.50 23.60 23.00 FA4ANA030000
11.70 7.50 23.60 22.60 FA4ANF024000
12.00 7.50 23.60 23.00 FA4ANF030000
11.70 7.50 23.60 22.60 FB4ANA024000
12.00 7.50 23.60 23.00 FB4ANA030000
11.70 7.50 23.60 22.60 FB4ANF024000
12.00 7.50 23.60 23.00 FB4ANF030000
11.70 7.50 23.60 22.60 FC4BNF024000
12.00 7.50 23.60 23.00 FC4BNF030000
11.70 7.40 23.60 22.20 FD3ANA024000
12.10 7.50 23.60 23.20 FD3ANA030000
11.70 7.50 23.60 22.60 FF1ANA024000
12.00 7.50 23.60 23.20 FF1ANA030000
11.70 7.50 23.60 22.60 FF1BNA024000
12.00 7.50 23.60 23.20 FF1BNA030000
11.60 7.40 23.60 22.20 FG3AAA024000
13.00 8.00 23.60 23.80 FK4BNF001000
13.20 8.00 23.60 24.00 FK4BNF002000
13.50 8.10 23.60 24.20 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1801COP
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.70 7.30 23.60 22.40 CC5AXA024000
12.00 7.30 23.60 22.60 CC5AXA030000
12.00 7.30 23.60 22.60 CC5AXW030000
11.70 7.30 23.60 22.40 CD5AXA024000
12.00 7.30 23.60 22.60 CD5AXA030000
12.00 7.30 23.60 22.60 CD5AXW030000
11.70 7.30 23.60 22.40 CD5BXA024000
12.00 7.30 23.60 22.60 CD5BXA030000
12.00 7.30 23.60 22.60 CD5BXW030000
11.80 7.30 23.60 22.60 CF5AXA024000
11.50 11.80 7.30 23.60 22.60 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.70 7.30 23.60 22.40 CD3AXA024000
12.00 7.30 23.60 22.60 CD3AXA030000
11.70 7.30 23.60 22.40 CD3BXA024000
12.00 7.30 23.60 22.60 CD3BXA030000
11.80 7.40 23.80 22.40 CD3CXA024000
11.80 7.40 23.80 22.40 CD3CXA030000
12.00 7.50 23.80 22.60 CD3CXA036000
11.80 7.30 23.60 22.60 CE3AXA024000
12.00 7.50 23.60 23.00 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 62: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/62.jpg)
38BYB03030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.20 7.50 29.20 28.00 FA4ANA030000
12.20 7.50 29.20 28.00 FA4ANF030000
12.10 7.60 29.60 28.40 FA4ANF036000
12.20 7.50 29.20 28.00 FB4ANA030000
12.20 7.50 29.20 28.00 FB4ANF030000
12.10 7.60 29.60 28.40 FB4ANF036000
12.20 7.50 29.20 28.00 FC4BNF030000
12.10 7.60 29.60 28.40 FC4BNF036000
12.20 7.50 29.60 28.20 FD3ANA030000
12.20 7.50 29.40 28.20 FF1ANA030000
12.20 7.50 29.40 28.20 FF1BNA030000
12.20 7.50 29.40 28.40 FG3AAA036000
13.00 7.90 29.20 28.80 FK4BNF001000
13.20 8.00 29.40 29.00 FK4BNF002000
13.50 8.10 28.80 29.20 FK4BNF003000
13.50 8.20 29.20 29.60 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1801COP
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.10 7.30 29.00 27.80 CC5AXA030000
12.50 7.50 29.40 28.80 CC5AXA036000
12.10 7.30 29.00 27.80 CC5AXW030000
12.10 7.30 29.00 27.80 CD5AXA030000
12.50 7.50 29.40 28.80 CD5AXA036000
12.10 7.30 29.00 27.80 CD5AXW030000
12.50 7.50 29.40 28.80 CD5AXW036000
12.10 7.30 29.00 27.80 CD5BXA030000
12.50 7.50 29.40 28.80 CD5BXA036000
12.10 7.30 29.00 27.80 CD5BXW030000
12.50 7.50 29.40 28.80 CD5BXW036000
12.50 7.50 29.40 28.40 CF5AXA036000
12.20 12.50 7.50 29.40 28.40 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.10 7.30 29.00 27.80 CD3AXA030000
12.50 7.50 29.40 28.80 CD3AXA036000
12.10 7.30 29.00 27.80 CD3BXA030000
12.50 7.50 29.40 28.80 CD3BXA036000
12.00 7.50 29.40 27.40 CD3CXA030000
12.10 7.50 29.40 28.00 CD3CXA036000
12.10 7.50 29.40 28.00 CE3AXA030000
12.30 7.50 29.40 28.40 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 63: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/63.jpg)
38BYB03630 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.10 8.00 35.80 33.80 FA4ANB042000
11.70 7.60 36.00 33.00 FA4ANF036000
12.10 8.00 35.80 33.80 FA4ANF042000
12.10 8.00 35.80 33.80 FB4ANB042000
11.70 7.60 36.00 33.00 FB4ANF036000
12.10 8.00 35.80 33.80 FB4ANF042000
12.10 8.00 35.80 33.80 FC4BNB042000
11.70 7.60 36.00 33.00 FC4BNF036000
12.10 8.00 35.80 33.80 FC4BNF042000
12.00 7.70 35.80 33.00 FG3AAA036000
13.50 8.30 35.60 35.60 FK4BNB005000
12.10 7.80 35.60 33.40 FK4BNF001000
12.20 8.00 36.00 33.40 FK4BNF002000
13.00 8.10 35.20 34.00 FK4BNF003000
13.00 8.20 36.00 34.40 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH0601COP
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.10 7.70 35.80 33.60 CC5AXA036000
12.10 7.70 35.80 33.60 CC5AXA042000
12.10 7.60 35.80 33.40 CC5AXW042000
12.10 7.70 35.80 33.60 CD5AXA036000
12.10 7.70 35.80 33.60 CD5AXA042000
12.10 7.70 35.80 33.60 CD5AXW036000
12.10 7.60 35.80 33.40 CD5AXW042000
12.10 7.70 35.80 33.60 CD5BXA036000
12.10 7.70 35.80 33.60 CD5BXA042000
12.10 7.70 35.80 33.60 CD5BXW036000
12.10 7.60 35.80 33.40 CD5BXW042000
12.10 7.70 35.80 33.40 CF5AXA036000
12.00 12.10 7.70 35.80 33.40 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.10 7.70 35.80 33.60 CD3AXA036000
12.10 7.70 35.80 33.60 CD3AXA042000
12.10 7.70 35.80 33.60 CD3BXA036000
12.10 7.70 35.80 33.60 CD3BXA042000
11.80 7.70 35.60 32.40 CD3CXA036000
11.80 7.70 35.60 32.40 CD3CXA042000
12.00 8.00 35.80 33.20 CD3CXA048000
12.00 7.60 35.60 33.20 CE3AXA036000
12.10 7.70 36.00 33.80 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 64: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/64.jpg)
38BYB04230 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.70 7.60 42.50 39.50 FA4ANB042000
12.00 8.00 43.00 40.00 FA4ANB048000
11.70 7.60 42.50 39.50 FA4ANF042000
12.00 8.00 43.00 40.00 FA4ANF048000
11.70 7.60 42.50 39.50 FB4ANB042000
12.00 8.00 43.00 40.00 FB4ANB048000
11.70 7.60 42.50 39.50 FB4ANF042000
12.00 8.00 43.00 40.00 FB4ANF048000
11.70 7.60 42.50 39.50 FC4BNB042000
12.00 8.00 43.00 40.00 FC4BNB048000
12.00 8.00 43.00 40.50 FC4BNF038000
11.70 7.60 42.50 39.50 FC4BNF042000
12.00 8.00 43.00 40.00 FC4BNF048000
11.70 7.70 42.50 39.50 FG3AAA048000
13.00 8.30 42.50 42.00 FK4BNB005000
13.20 8.50 42.50 42.50 FK4BNB006000
12.50 7.90 41.50 39.50 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Islation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH0601COP
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 7.50 42.00 39.00 CC5AXA042000
11.80 7.50 42.00 39.00 CC5AXC048000
11.80 7.50 43.50 39.00 CC5AXW042000
12.00 7.60 42.50 40.00 CC5AXW048000
12.00 7.50 42.00 39.00 CD5AXA042000
12.00 7.60 42.50 40.00 CD5AXA048000
11.80 7.50 42.00 39.00 CD5AXC048000
11.80 7.50 43.50 39.00 CD5AXW042000
12.00 7.60 42.50 40.00 CD5AXW048000
12.00 7.50 42.00 39.00 CD5BXA042000
12.00 7.60 42.50 40.00 CD5BXA048000
11.80 7.50 42.00 39.00 CD5BXC048000
11.80 7.50 43.50 39.00 CD5BXW042000
12.00 7.60 42.50 40.00 CD5BXW048000
12.00 7.60 42.00 40.00 CF5AXA048000
11.70 12.00 7.60 42.00 40.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 7.50 42.00 39.00 CD3AXA042000
11.90 7.60 42.50 40.00 CD3AXA048000
12.00 7.50 42.00 39.00 CD3BXA042000
11.90 7.60 42.50 40.00 CD3BXA048000
11.70 7.50 42.00 38.00 CD3CXA042000
12.00 7.70 42.00 39.00 CD3CXA048000
12.00 7.60 42.50 39.50 CE3AXA042000
12.00 7.70 42.50 40.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 65: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/65.jpg)
38BYB04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.50 7.60 48.00 45.50 FA4ANB048000
11.60 7.70 48.00 47.00 FA4ANB060000
11.50 7.60 48.00 45.50 FA4ANF048000
11.60 7.70 48.00 47.00 FA4ANF060000
11.50 7.60 48.00 45.50 FB4ANB048000
11.60 7.70 48.00 47.00 FB4ANB060000
12.00 8.00 48.00 48.00 FB4ANB070000
11.50 7.60 48.00 45.50 FB4ANF048000
11.60 7.70 48.00 47.00 FB4ANF060000
11.50 7.60 48.00 45.50 FC4BNB048000
12.10 8.00 48.00 48.00 FC4BNB054000
11.60 7.70 48.00 47.00 FC4BNB060000
11.50 7.60 48.00 45.50 FC4BNF048000
11.60 7.70 48.00 47.00 FC4BNF060000
11.40 7.50 48.00 45.00 FG3AAA048000
11.80 7.70 48.00 46.00 FG3AAA060000
13.00 8.00 48.00 47.50 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKHAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1701COP
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 7.30 48.00 45.00 CC5AXA060000
11.30 7.00 48.00 44.00 CC5AXC048000
11.40 7.40 48.00 44.50 CC5AXW048000
12.00 7.70 48.00 46.50 CC5AXW060000
11.40 7.40 48.00 44.50 CD5AXA048000
11.50 7.30 48.00 45.00 CD5AXA060000
11.30 7.00 48.00 44.00 CD5AXC048000
11.40 7.40 48.00 44.50 CD5AXW048000
12.00 7.70 48.00 46.50 CD5AXW060000
11.40 7.40 48.00 44.50 CD5BXA048000
11.50 7.30 48.00 45.00 CD5BXA060000
11.30 7.00 48.00 44.00 CD5BXC048000
11.40 7.40 48.00 44.50 CD5BXW048000
11.70 7.70 48.00 46.50 CD5BXW060000
11.50 7.30 48.00 45.00 CF5AXA048000
11.20 11.50 7.30 48.00 45.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.40 7.40 48.00 44.50 CD3AXA048000
11.50 7.30 48.00 45.00 CD3AXA060000
11.40 7.40 48.00 44.50 CD3BXA048000
11.50 7.30 48.00 45.00 CD3BXA060000
11.10 7.50 48.00 44.50 CD3CXA048000
11.50 7.70 48.50 46.00 CD3CXA060000
11.60 7.80 48.50 46.50 CD3CXA070000
11.50 7.50 48.00 45.00 CE3AXA048000
12.00 7.70 48.00 46.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 66: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/66.jpg)
38BYB06030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.20 7.50 60.50 54.50 FA4ANB060000
11.20 7.50 60.50 54.50 FA4ANF060000
11.20 7.50 60.50 54.50 FB4ANB060000
11.50 7.70 60.50 55.50 FB4ANB070000
11.20 7.50 60.50 54.50 FB4ANF060000
11.20 7.50 60.50 54.50 FC4BNB060000
11.20 7.50 60.50 54.50 FC4BNF060000
11.40 7.30 59.50 53.50 FG3AAA060000
12.00 8.00 60.00 56.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1401HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC40GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Motormaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKHAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Sound BlanketKSASH1701COP
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.10 7.00 58.50 52.00 CC5AXA060000
11.40 7.30 59.50 53.50 CC5AXW060000
11.10 7.00 58.50 52.00 CD5AXA060000
11.40 7.30 59.50 53.50 CD5AXW060000
11.10 7.00 58.50 52.00 CD5BXA060000
11.40 7.30 59.50 53.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.10 7.00 58.50 52.00 CD3AXA060000
11.10 7.00 58.50 52.00 CD3BXA060000
11.00 7.30 60.00 53.00 CD3CXA060000
11.20 7.50 60.00 54.00 CD3CXA070000
11.50 7.30 59.50 54.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 67: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/67.jpg)
38YCB01830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.00 17.50 17.00 FA4ANF018000
10.10 10.10 7.20 18.00 18.00 FA4ANF024000
10.00 10.00 7.00 17.50 17.00 FB4ANF018000
10.10 10.10 7.20 18.00 18.00 FB4ANF024000
10.10 7.20 18.00 18.00 FC4BNF024000
10.00 7.00 17.50 17.50 FD3ANA024000
10.00 10.00 7.00 17.50 17.00 FF1ANA018000
10.20 10.20 7.20 17.60 17.80 FF1ANA024000
10.00 10.00 7.00 17.50 17.00 FF1BNA018000
10.20 10.20 7.20 17.60 17.80 FF1BNA024000
10.00 6.80 16.80 17.50 FG3AAA024000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Size dependent on home duct size.5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers4
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers4
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH1101COP
TXV (RPB)KHATX0201RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 6.80 17.00 17.50 CC5AXA018000
10.10 7.00 17.50 17.80 CC5AXA024000
10.00 6.80 17.00 17.50 CD5AXA018000
10.10 7.00 17.50 17.80 CD5AXA024000
10.00 6.80 17.00 17.50 CD5BXA018000
10.10 7.00 17.50 17.80 CD5BXA024000
10.10 7.20 17.50 17.80 CF5AXA024000
10.10 7.20 17.50 17.80 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 6.80 17.00 17.50 CD3AXA018000
10.10 7.00 17.50 17.80 CD3AXA024000
10.00 6.80 17.00 17.50 CD3BXA018000
10.10 7.00 17.50 17.80 CD3BXA024000
10.10 7.00 17.50 17.80 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 68: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/68.jpg)
38YCB02430 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.00 22.80 22.60 FA4ANF024000
10.00 10.00 7.00 22.80 22.80 FA4ANF030000
10.00 10.00 7.00 22.80 22.60 FB4ANF024000
10.00 10.00 7.00 22.80 22.80 FB4ANF030000
10.00 7.00 22.80 22.60 FC4BNF024000
10.00 7.00 22.80 22.80 FC4BNF030000
10.00 6.90 22.80 22.00 FD3ANA024000
10.00 7.00 22.80 23.00 FD3ANA030000
10.00 10.00 7.00 22.80 22.00 FF1ANA024000
10.00 10.00 7.00 22.80 23.00 FF1ANA030000
10.00 10.00 7.00 22.80 22.00 FF1BNA024000
10.00 10.00 7.00 22.80 23.00 FF1BNA030000
11.00 7.20 22.00 23.00 FK4BNF001000
11.10 7.20 21.00 23.20 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2424
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH1101COP
TXV (RPB)KHATX0301RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 6.90 22.80 22.40 CC5AXA024000
10.00 6.90 22.80 22.80 CC5AXA030000
10.00 6.90 22.80 22.80 CC5AXW030000
10.00 6.90 22.80 22.40 CD5AXA024000
10.00 6.90 22.80 22.80 CD5AXA030000
10.00 6.90 22.80 22.80 CD5AXW030000
10.00 6.90 22.80 22.40 CD5BXA024000
10.00 6.90 22.80 22.80 CD5BXA030000
10.00 6.90 22.80 22.80 CD5BXW030000
10.00 6.90 22.80 22.60 CF5AXA024000
10.00 6.90 22.80 22.60 CG5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 6.90 22.80 22.40 CD3AXA024000
10.00 6.90 22.80 22.80 CD3AXA030000
10.00 6.90 22.80 22.40 CD3BXA024000
10.00 6.90 22.80 22.80 CD3BXA030000
10.00 6.90 22.80 22.60 CE3AXA024000
10.00 7.00 22.80 23.00 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 69: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/69.jpg)
38YCB03030 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.20 29.00 28.20 FA4ANF030000
10.00 10.00 7.20 29.20 28.40 FA4ANF036000
10.00 10.00 7.20 29.00 28.20 FB4ANF030000
10.00 10.00 7.20 29.20 28.40 FB4ANF036000
10.00 7.20 29.00 28.20 FC4BNF030000
10.00 7.20 29.20 28.40 FC4BNF036000
10.00 7.20 29.00 28.00 FD3ANA030000
10.00 10.00 7.20 29.00 28.20 FF1ANA030000
10.00 10.00 7.20 29.00 28.20 FF1BNA030000
10.00 7.20 29.00 28.20 FG3AAA036000
10.50 7.30 28.60 28.40 FK4BNF001000
10.60 7.50 28.80 28.60 FK4BNF002000
11.00 7.50 28.00 29.00 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCStandard
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH1101COP
TXV (RPB)KHATX0401RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 7.00 28.60 27.80 CC5AXA030000
10.20 7.20 29.20 28.60 CC5AXA036000
10.00 7.00 28.60 27.80 CC5AXW030000
10.00 7.00 28.60 27.80 CD5AXA030000
10.20 7.20 29.20 28.60 CD5AXA036000
10.00 7.00 28.60 27.80 CD5AXW030000
10.20 7.20 29.20 28.60 CD5AXW036000
10.00 7.00 28.60 27.80 CD5BXA030000
10.20 7.20 29.20 28.60 CD5BXA036000
10.00 7.00 28.60 27.80 CD5BXW030000
10.20 7.20 29.20 28.60 CD5BXW036000
10.00 7.20 29.00 28.20 CF5AXA036000
10.00 7.20 29.00 28.20 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 7.00 28.60 27.80 CD3AXA030000
10.20 7.20 29.20 28.60 CD3AXA036000
10.00 7.00 28.60 27.80 CD3BXA030000
10.20 7.20 29.20 28.60 CD3BXA036000
10.00 7.00 29.00 28.00 CE3AXA030000
10.00 7.20 29.00 28.20 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 70: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/70.jpg)
38YCB03630 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.20 10.20 7.50 36.00 34.80 FA4ANB042000
10.00 10.00 7.20 36.00 34.20 FA4ANF036000
10.20 10.20 7.50 36.00 34.80 FA4ANF042000
10.20 10.20 7.50 36.00 34.80 FB4ANB042000
10.00 10.00 7.20 36.00 34.20 FB4ANF036000
10.20 10.20 7.50 36.00 34.80 FB4ANF042000
10.20 7.50 36.00 34.80 FC4BNB042000
10.00 7.20 36.00 34.20 FC4BNF036000
10.20 7.50 36.00 34.80 FC4BNF042000
10.00 7.20 36.00 34.00 FG3AAA036000
11.00 7.40 36.00 34.20 FK4BNF001000
11.00 7.60 36.00 34.20 FK4BNF002000
11.20 7.60 35.60 34.40 FK4BNF003000
11.20 7.80 36.00 34.40 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8083S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH1901CYL
TXV (RPB)KHATX0501RPB
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 7.20 36.00 34.20 CC5AXA036000
10.20 7.20 36.00 34.80 CC5AXA042000
10.20 7.20 36.00 34.40 CC5AXW042000
10.00 7.20 36.00 34.20 CD5AXA036000
10.20 7.20 36.00 34.80 CD5AXA042000
10.00 7.20 36.00 34.20 CD5AXW036000
10.20 7.20 36.00 34.40 CD5AXW042000
10.00 7.20 36.00 34.20 CD5BXA036000
10.20 7.20 36.00 34.80 CD5BXA042000
10.00 7.20 36.00 34.20 CD5BXW036000
10.20 7.20 36.00 34.40 CD5BXW042000
10.00 7.20 36.00 34.20 CF5AXA036000
10.00 7.20 36.00 34.20 CG5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 7.20 36.00 34.20 CD3AXA036000
10.20 7.20 36.00 34.80 CD3AXA042000
10.00 7.20 36.00 34.20 CD3BXA036000
10.20 7.20 36.00 34.80 CD3BXA042000
10.00 7.20 36.00 34.20 CE3AXA036000
10.20 7.20 36.00 34.60 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 71: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/71.jpg)
38YCB04230 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.20 42.00 40.50 FA4ANB042000
10.00 10.00 7.20 42.00 41.00 FA4ANB048000
10.00 10.00 7.20 42.00 40.50 FA4ANF042000
10.00 10.00 7.20 42.00 41.00 FA4ANF048000
10.00 10.00 7.20 42.00 40.50 FB4ANB042000
10.00 10.00 7.20 42.00 41.00 FB4ANB048000
10.00 10.00 7.20 42.00 40.50 FB4ANF042000
10.00 10.00 7.20 42.00 41.00 FB4ANF048000
10.00 7.20 42.00 40.50 FC4BNB042000
10.00 7.20 42.00 41.00 FC4BNB048000
10.00 7.20 42.00 40.50 FC4BNF042000
10.00 7.20 42.00 41.00 FC4BNF048000
10.00 7.20 42.00 41.00 FG3AAA048000
11.00 7.50 41.00 41.00 FK4BNB005000
10.50 7.30 42.00 40.00 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH2001CYL
TXV (RPB)KHATX0501RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 7.20 42.00 40.50 CC5AXA042000
10.00 7.00 42.00 40.50 CC5AXC048000
10.00 7.10 42.00 40.50 CC5AXW042000
10.00 7.20 42.00 41.00 CC5AXW048000
10.00 7.20 42.00 40.50 CD5AXA042000
10.00 7.20 42.00 41.00 CD5AXA048000
10.00 7.00 42.00 40.50 CD5AXC048000
10.00 7.10 42.00 40.50 CD5AXW042000
10.00 7.20 42.00 41.00 CD5AXW048000
10.00 7.20 42.00 40.50 CD5BXA042000
10.00 7.20 42.00 41.00 CD5BXA048000
10.00 7.20 42.00 41.00 CD5BXA048000
10.00 7.00 42.00 40.50 CD5BXC048000
10.00 7.10 42.00 40.50 CD5BXW042000
10.00 7.20 42.00 41.00 CD5BXW048000
10.00 7.20 42.00 41.00 CF5AXA048000
10.00 7.20 42.00 41.00 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 7.20 42.00 40.50 CD3AXA042000
10.00 7.20 42.00 41.00 CD3AXA048000
10.00 7.20 42.00 40.50 CD3BXA042000
10.00 7.20 42.00 41.00 CD3BXA048000
10.00 7.20 42.00 41.00 CE3AXA042000
10.00 7.00 42.00 41.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 72: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/72.jpg)
38YCB04830 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.20 47.00 46.00 FA4ANB048000
10.30 10.30 7.50 47.00 46.50 FA4ANB060000
10.00 10.00 7.20 47.00 46.00 FA4ANF048000
10.30 10.30 7.50 47.00 46.50 FA4ANF060000
10.00 10.00 7.20 47.00 46.00 FB4ANB048000
10.30 10.30 7.50 47.00 46.50 FB4ANB060000
10.50 10.50 7.50 47.00 47.00 FB4ANB070000
10.00 10.00 7.20 47.00 46.00 FB4ANF048000
10.30 10.30 7.50 47.00 46.50 FB4ANF060000
10.00 7.20 47.00 46.00 FC4BNB048000
10.30 7.50 47.00 46.50 FC4BNB060000
10.50 7.50 47.00 47.00 FC4BNB070000
10.00 7.20 47.00 46.00 FC4BNF048000
10.30 7.50 47.00 46.50 FC4BNF060000
10.00 7.20 47.00 45.00 FG3AAA048000
10.50 7.40 47.00 46.00 FG3AAA060000
11.00 7.60 45.00 47.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH2001CYL
TXV (RPB)KHATX0601RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 7.20 46.50 45.00 CC5AXA060000
10.00 7.00 46.00 44.00 CC5AXC048000
10.00 7.20 46.50 45.00 CC5AXW048000
10.00 7.20 47.00 46.00 CC5AXW060000
10.00 7.20 46.50 45.00 CD5AXA048000
10.00 7.20 46.50 45.00 CD5AXA060000
10.00 7.00 46.00 44.00 CD5AXC048000
10.00 7.20 46.50 45.00 CD5AXW048000
10.00 7.20 47.00 46.00 CD5AXW060000
10.00 7.20 46.50 45.00 CD5BXA048000
10.00 7.20 46.50 45.00 CD5BXA060000
10.00 7.00 46.00 44.00 CD5BXC048000
10.00 7.20 46.50 45.00 CD5BXW048000
10.00 7.20 47.00 46.00 CD5BXW060000
10.50 7.20 46.50 45.00 CF5AXA048000
10.50 7.20 46.50 43.00 CG5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 7.20 46.50 45.00 CD3AXA048000
10.00 7.20 46.50 45.00 CD3AXA060000
10.00 7.20 46.50 45.00 CD3BXA048000
10.00 7.20 46.50 45.00 CD3BXA060000
10.00 7.20 47.00 45.00 CE3AXA048000
10.50 7.50 47.00 46.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 73: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/73.jpg)
38YCB06030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.20 10.20 7.50 58.00 56.00 FA4ANB060000
10.20 10.20 7.50 58.00 56.00 FA4ANF060000
10.20 10.20 7.50 58.00 56.00 FB4ANB060000
10.50 10.50 7.50 57.00 56.50 FB4ANB070000
10.20 10.20 7.50 58.00 56.00 FB4ANF060000
10.20 7.50 58.00 56.00 FC4BNB060000
10.50 7.50 57.00 56.50 FC4BNB070000
10.20 7.50 58.00 56.00 FC4BNF060000
10.50 7.20 56.50 54.50 FG3AAA060000
11.00 7.60 53.50 56.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Auto ChangeoverProgrammable Dual
Fuel9
TSTATCCPDF01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3030
Filter DrierP504-8163S
Heat Pump RisersP165-0001
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Snow RackN/A
Sound BlanketKSASH2001CYL
TXV (RPB)KHATX0701RPB
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.20 7.00 56.00 53.50 CC5AXA060000
10.50 7.50 56.50 55.50 CC5AXW060000
10.20 7.00 56.00 53.50 CD5AXA060000
10.50 7.50 56.50 55.50 CD5AXW060000
10.20 7.00 56.00 53.50 CD5BXA060000
10.50 7.50 56.50 55.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 7.00 56.00 53.50 CD3AXA060000
10.20 7.00 56.00 53.50 CD3BXA060000
10.20 7.50 56.50 56.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 74: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/74.jpg)
38YDA03630 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS12.30 7.70 34.00 37.40 FA4ANB042000
11.80 7.50 34.00 36.00 FA4ANF036000
12.30 7.70 34.00 37.40 FA4ANF042000
12.30 7.70 34.00 37.40 FB4ANB042000
11.80 7.50 34.00 36.00 FB4ANF036000
12.30 7.70 34.00 37.40 FB4ANF042000
12.30 7.70 34.00 37.40 FC4BNB042000
11.80 7.50 34.00 36.00 FC4BNF036000
12.30 7.70 34.00 37.40 FC4BNF042000
16.10 8.80 35.00 40.00 FK4CNB006000
14.20 7.50 33.00 36.00 FK4CNF001000
14.50 8.00 34.00 36.60 FK4CNF002000
14.90 8.15 34.00 37.40 FK4CNF003000
15.45 8.50 34.80 38.50 FK4CNF005000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. TXV required2. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
3. Thermostat not needed if Carrier Comfort Zone kit is purchased.4. TXV required, field supplied (except FK Fan Coils).5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. May not be required for application. Consult zoning information.9. Low-ambient operation accessory is not available. Minimum outdoor operating air temp. is 55 F.10. Latent kit recommended on all non variable speed indoor sections.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular DampersDAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart Sensor ConnectorBoard
ZONESMSENCBD
Smart Sensor Power PackZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Outdoor SensorTSTATCCSEN01
TXV (HSO)KHATX1501HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCN/A
Start CapacitorStandard
See Note9
Cycle Protector
Standard
Filter DrierP504-8163S
High Pressure SwitchStandard
Latent Capacity "C"Furnace Humidistat &
Relay10
Low Pressure SwitchStandard
Snow StandKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow13.00 7.75 34.00 37.60 CC5AXA036000
13.00 7.75 34.00 37.60 CC5AXA042000
12.90 7.75 34.00 37.60 CC5AXW042000
13.00 7.75 34.00 37.60 CD5AXA036000
13.00 7.75 34.00 37.60 CD5AXA042000
13.00 7.75 34.00 37.60 CD5AXW036000
12.90 7.75 34.00 37.60 CD5AXW042000
13.00 7.75 34.00 37.60 CD5BXA036000
13.00 7.75 34.00 37.60 CD5BXA042000
13.00 7.75 34.00 37.60 CD5BXW036000
12.90 7.75 34.00 37.60 CD5BXW042000
13.00 7.50 34.00 34.00 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TMA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.00 7.75 34.00 37.60 CD3AXA036000
13.00 7.75 34.00 37.60 CD3AXA042000
13.00 7.75 34.00 37.60 CD3BXA036000
13.00 7.75 34.00 37.60 CD3BXA042000
12.80 7.50 33.40 37.00 CE3AXA036000
13.00 7.60 33.60 37.60 CE3AXA042000
Furnan Blk 4Horizontal
58EFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER
AIRTREATMENT ZONING2 THERMOSTAT3
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT4
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN3
FURNACE COILS14.70 8.00 33.00 37.00 CC5AXA036000
14.70 8.00 33.00 37.00 CC5AXA042000
14.70 8.00 33.00 37.00 CC5AXW042000
14.70 8.00 33.00 37.00 CD3AXA036000
14.70 8.00 33.00 37.00 CD3AXA042000
14.70 8.00 33.00 37.00 CD3BXA036000
14.70 8.00 33.00 37.00 CD3BXA042000
14.70 8.00 33.00 37.00 CD5AXA036000
14.70 8.00 33.00 37.00 CD5AXA042000
14.70 8.00 33.00 37.00 CD5AXW036000
14.70 8.00 33.00 37.00 CD5AXW042000
14.70 8.00 33.00 37.00 CD5BXA036000
14.70 8.00 33.00 37.00 CD5BXA042000
Furnan Blk 5
Down/Upflow58MVP100---1--20
Does Not Apply
![Page 75: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/75.jpg)
38YDA04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS11.30 7.70 50.00 48.00 FA4ANB048000
11.00 7.70 50.00 50.00 FA4ANB060000
11.30 7.70 50.00 48.00 FA4ANF048000
11.00 7.70 50.00 50.00 FA4ANF060000
11.30 7.70 50.00 48.00 FB4ANB048000
11.00 7.70 50.00 50.00 FB4ANB060000
11.80 8.00 50.50 51.50 FB4ANB070000
11.30 7.70 50.00 48.00 FB4ANF048000
11.00 7.70 50.00 50.00 FB4ANF060000
11.30 7.70 50.00 48.00 FC4BNB048000
11.00 7.70 50.00 50.00 FC4BNB060000
11.80 8.00 50.50 51.50 FC4BNB070000
11.30 7.70 50.00 48.00 FC4BNF048000
11.00 7.70 50.00 50.00 FC4BNF060000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. TXV required2. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
3. Thermostat not needed if Carrier Comfort Zone kit is purchased.4. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.5. See price pages for complete listing of line sets.6. Size dependent on home duct size.7. May not be required for application. Consult zoning information.8. TXV required, field supplied (except FK Fan Coils).9. Low-ambient operation accessory is not available. Minimum outdoor operating air temp. is 55 F.10. Latent kit recommended on all non variable speed indoor sections.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular DampersDAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers6
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart Sensor ConnectorBoard
ZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Outdoor SensorTSTATCCSEN01
TXV (HSO)8
KHATX1501HSO Crankcase Heater
Standard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCN/A
Start CapacitorStandard
See Note9
Cycle Protector
Standard
Filter DrierP504-8163S
High Pressure SwitchStandard
Latent Capacity "C"Furnace Humidistat &
Relay10
Low Pressure SwitchStandard
Snow StandKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 7.60 49.00 48.00 CC5AXA060000
12.00 7.60 49.00 48.00 CC5AXW048000
12.40 7.80 49.50 49.00 CC5AXW060000
12.00 7.60 49.00 48.00 CD5AXA048000
12.00 7.60 49.00 48.00 CD5AXA060000
12.00 7.60 49.00 48.00 CD5AXW048000
12.40 7.80 49.50 49.00 CD5AXW060000
12.00 7.60 49.00 48.00 CD5BXA048000
12.00 7.60 49.00 48.00 CD5BXA060000
12.00 7.60 49.00 48.00 CD5BXW048000
12.40 7.80 49.50 49.00 CD5BXW060000
12.00 7.60 49.00 48.00 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 7.60 49.00 48.00 CD3AXA048000
12.00 7.60 49.00 48.00 CD3AXA060000
12.00 7.60 49.00 48.00 CD3BXA048000
12.00 7.60 49.00 48.00 CD3BXA060000
12.00 7.60 49.00 48.00 CE3AXA048000
12.40 7.80 49.50 49.00 CE3AXA060000
Furnan Blk 4Horizontal
58EFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER
AIRTREATMENT ZONING2 THERMOSTAT3
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET5SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE4
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN3
FURNACE COILS13.00 7.80 49.50 47.00 CC5AXA060000
13.00 7.80 49.00 47.00 CC5AXW048000
13.40 8.00 49.50 48.00 CC5AXW060000
13.00 7.80 49.00 47.00 CD3AXA048000
13.00 7.80 49.00 47.00 CD3AXA060000
13.00 7.80 49.00 47.00 CD3BXA048000
13.00 7.80 49.00 47.00 CD3BXA060000
13.00 7.80 49.00 47.00 CD5AXA048000
13.00 7.80 49.50 47.00 CD5AXA060000
13.00 7.80 49.00 47.00 CD5AXW048000
13.40 8.00 49.50 48.00 CD5AXW060000
13.00 7.80 49.00 47.00 CD5BXA048000
13.00 7.80 49.50 47.00 CD5BXA060000
13.00 7.80 49.00 47.00 CD5BXW048000
13.40 8.00 49.50 48.00 CD5BXW060000
13.00 7.70 49.00 47.00 CE3AXA048000
13.40 7.80 49.00 48.00 CE3AXA060000
Furnan Blk 5
Down/Upflow58MVP100---1--20
Does Not Apply
![Page 76: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/76.jpg)
38YDA06030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $
FAN COILS10.80 7.70 52.00 56.00 FA4ANB060000
10.80 7.70 52.00 56.00 FA4ANF060000
10.80 7.70 52.00 56.00 FB4ANB060000
11.60 8.00 52.00 57.00 FB4ANB070000
10.80 7.70 52.00 56.00 FB4ANF060000
10.80 7.70 52.00 56.00 FC4BNB060000
11.60 8.00 52.00 57.00 FC4BNB070000
10.80 7.70 52.00 56.00 FC4BNF060000
14.00 8.30 55.50 57.00 FK4CNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. TXV required2. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
3. Thermostat not needed if Carrier Comfort Zone kit is purchased.4. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.5. See price pages for complete listing of line sets.6. Size dependent on home duct size.7. May not be required for application. Consult zoning information.8. TXV required, field supplied (except FK Fan Coils).9. Low-ambient operation accessory is not available. Minimum outdoor operating air temp. is 55 F.10. Latent kit recommended on all non variable speed indoor sections.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular DampersDAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers6
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart Sensor ConnectorBoard
ZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day ProgrammableTSTATCCP2S01-A
Auto ChangeoverNon-ProgrammableTSTATCCN2S01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Outdoor SensorTSTATCCSEN01
TXV (HSO)8
KHATX1501HSO Crankcase Heater
Standard
Cycle ProtectorStandard
Filter DrierP504-8163S
Start Assist-PTCN/A
Start CapacitorStandard
See Note9
Cycle Protector
Standard
Filter DrierP504-8163S
High Pressure SwitchStandard
Latent Capacity "C"Furnace Humidistat &
Relay10
Low Pressure SwitchStandard
Snow StandKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
P850-20618-08SB(50 FT )
P850-30618-08SB(50 FT )
P850-40618-08SB(50 FT )
P850-50618-08SB(50 FT )
P850-60618-08SB(50 FT )
P850-70618-08SB(50 FT )
P850-90618-08SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.70 7.70 49.50 54.50 CC5AXA060000
12.00 7.80 51.00 56.00 CC5AXW060000
11.70 7.70 49.50 54.50 CD5AXA060000
12.00 7.80 51.00 56.00 CD5AXW060000
11.70 7.70 49.50 54.50 CD5BXA060000
12.00 7.80 51.00 56.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.70 7.70 49.50 54.50 CD3AXA060000
11.70 7.70 49.50 54.50 CD3BXA060000
12.00 7.80 50.00 56.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER
AIRTREATMENT ZONING2 THERMOSTAT3
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET5SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE4
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
FURNAN3
FURNACE COILS12.80 7.60 47.50 52.50 CC5AXA060000
13.00 7.80 48.50 54.00 CC5AXW060000
12.80 7.60 47.50 52.50 CD3AXA060000
12.80 7.60 47.50 52.50 CD3BXA060000
12.80 7.60 47.50 52.50 CD5AXA060000
13.00 7.80 48.50 54.00 CD5AXW060000
12.80 7.60 47.50 52.50 CD5BXA060000
13.00 7.80 48.50 54.00 CD5BXW060000
13.00 7.80 48.50 54.00 CE3AXA060000
Furnan Blk 5
Down/Upflow58MVP100---1--20
Does Not Apply
![Page 77: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/77.jpg)
38YKC01830 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.20 10.20 6.80 18.00 17.00 FA4ANF018000
10.50 10.50 7.00 18.20 17.50 FA4ANF024000
10.20 10.20 6.80 18.00 17.00 FB4ANF018000
10.50 10.50 7.00 18.20 17.50 FB4ANF024000
10.50 7.00 18.20 17.50 FC4BNF024000
10.00 6.80 18.00 17.00 FD3ANA018000
10.50 7.00 18.00 17.50 FD3ANA024000
10.50 10.50 6.80 17.90 17.00 FF1BNA018000
10.50 10.50 7.00 18.40 17.50 FF1BNA024000
10.50 6.90 18.00 17.50 FG3AAA024000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Coastal FilterKAACF0601SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2430
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0106MPK
Sound BlanketKSASH1301TEC
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
Line SetP850-20610-06PEB
(15 FT )P850-30610-06PEB
(20 FT )P850-40610-06PEB
(25 FT )P850-50610-06PEB
(30 FT )P850-60610-06PEB
(35 FT )P850-70610-06PEB
(40 FT )P850-90610-06PEB
(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.00 6.80 17.90 17.00 CC5AXA018000
10.50 7.00 18.00 17.50 CC5AXA024000
10.50 7.00 18.00 17.50 CC5AXW024000
10.00 6.80 17.90 17.00 CD5AXA018000
10.50 7.00 18.00 17.50 CD5AXA024000
10.50 7.00 18.00 17.50 CD5AXW024000
10.00 6.80 17.90 17.00 CD5BXA018000
10.50 7.00 18.00 17.50 CD5BXA024000
10.50 7.00 18.00 17.50 CD5BXW024000
10.50 7.00 18.00 17.50 CF5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.00 6.80 17.90 17.00 CD3AXA018000
10.50 7.00 18.00 17.50 CD3AXA024000
10.00 6.80 17.90 17.00 CD3BXA018000
10.50 7.00 18.00 17.50 CD3BXA024000
10.50 7.00 18.00 17.50 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 78: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/78.jpg)
38YKC02430 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.50 10.50 7.00 23.40 23.40 FA4ANF024000
10.50 10.50 7.00 23.40 24.00 FA4ANF030000
10.50 10.50 7.00 23.40 23.40 FB4ANF024000
10.50 10.50 7.00 23.40 24.00 FB4ANF030000
10.50 7.00 23.40 23.40 FC4BNF024000
10.50 7.00 23.40 24.00 FC4BNF030000
10.50 7.00 21.80 24.60 FC4BNF033000
10.50 6.80 23.00 23.00 FD3ANA024000
10.00 10.50 7.00 23.60 24.00 FD3ANA030000
10.50 10.50 7.00 23.60 23.40 FF1BNA024000
10.50 10.50 7.00 23.60 24.00 FF1BNA030000
10.00 6.80 23.00 23.00 FG3AAA024000
11.50 7.20 23.00 24.00 FK4BNF001000
11.50 7.50 22.20 24.00 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Coastal FilterKAACF0601SML
Cycle ProtectorKSACY0101AAA
Equipment PadP152-2430
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0106MPK
Sound BlanketKSASH1201COP
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 6.80 23.00 23.40 CC5AXA024000
10.00 10.50 6.80 23.00 23.60 CC5AXA030000
10.50 6.80 23.00 23.40 CC5AXW024000
10.00 10.50 6.80 23.00 23.60 CC5AXW030000
10.50 6.80 23.00 23.40 CD5AXA024000
10.00 10.50 6.80 23.00 23.60 CD5AXA030000
10.50 6.80 23.00 23.40 CD5AXW024000
10.00 10.50 6.80 23.00 23.60 CD5AXW030000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 6.80 23.00 23.40 CD3AXA024000
10.00 10.50 6.80 23.00 23.60 CD3AXA030000
10.50 6.80 23.00 23.40 CD3BXA024000
10.00 10.50 6.80 23.00 23.60 CD3BXA030000
10.00 10.50 6.80 23.20 23.60 CE3AXA024000
10.00 10.50 7.00 23.60 23.80 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 79: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/79.jpg)
38YKC03030 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.50 10.50 7.20 29.60 29.40 FA4ANF030000
10.50 10.50 7.20 30.00 29.80 FA4ANF036000
10.50 10.50 7.20 29.60 29.40 FB4ANF030000
10.50 10.50 7.20 30.00 29.80 FB4ANF036000
10.50 7.20 29.60 29.40 FC4BNF030000
10.50 7.50 29.60 30.00 FC4BNF033000
10.50 7.20 30.00 29.80 FC4BNF036000
10.50 7.20 30.00 29.40 FD3ANA030000
10.50 10.50 7.20 30.00 29.60 FF1BNA030000
10.50 7.20 28.90 29.60 FG3AAA036000
11.50 7.50 29.00 30.00 FK4ANF003000
11.00 7.50 29.80 30.00 FK4BNF001000
11.00 7.50 30.20 30.00 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorKSAHS0601AAA
Winter Start ControlN/A
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketKSASH1201COP
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 7.20 29.20 29.20 CC5AXA030000
10.00 10.50 7.20 29.80 30.00 CC5AXA036000
10.50 7.20 29.20 29.20 CC5AXW030000
10.50 7.20 29.20 29.20 CD3AXA030000
10.00 10.50 7.20 29.80 30.00 CD3AXA036000
10.50 7.20 29.20 29.20 CD3BXA030000
10.00 10.50 7.20 29.80 30.00 CD3BXA036000
10.50 7.20 29.20 29.20 CD5AXA030000
10.00 10.50 7.20 29.80 30.00 CD5AXA036000
10.50 7.20 29.20 29.20 CD5AXW030000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 7.20 29.20 29.20 CD3AXA030000
10.00 10.50 7.20 29.80 30.00 CD3AXA036000
10.50 7.20 29.20 29.20 CD3BXA030000
10.00 10.50 7.20 29.80 30.00 CD3BXA036000
10.50 7.20 29.80 29.40 CE3AXA030000
10.00 10.50 7.20 29.80 30.00 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 80: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/80.jpg)
38YKC03630 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.50 10.50 7.20 36.20 36.00 FA4ANB042000
10.00 10.00 7.20 36.00 35.40 FA4ANF036000
10.50 10.50 7.20 36.20 36.00 FA4ANF042000
10.50 10.50 7.20 36.20 36.00 FB4ANB042000
10.00 10.00 7.20 36.00 35.40 FB4ANF036000
10.50 10.50 7.20 36.20 36.00 FB4ANF042000
10.50 7.20 36.20 36.00 FC4BNB042000
10.50 7.20 36.20 36.00 FC4BNF033000
10.00 7.20 36.00 35.40 FC4BNF036000
10.50 7.20 36.20 36.00 FC4BNF042000
10.50 7.20 35.60 35.40 FG3AAA036000
10.50 7.20 35.40 35.60 FK4BNF001000
10.50 7.50 36.00 35.60 FK4BNF002000
11.50 7.50 35.20 36.00 FK4BNF003000
11.00 7.80 36.40 36.00 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorKSAHS0701AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorKSAHS0701AAA
Winter Start ControlN/A
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 7.20 35.80 36.00 CC5AXA036000
10.50 7.20 36.00 36.00 CC5AXA042000
10.50 7.20 35.80 36.00 CC5AXA043000
10.50 7.20 35.80 35.80 CC5AXW042000
10.50 7.20 35.80 36.00 CC5AXW043000
10.50 7.20 35.80 36.00 CD5AXA036000
10.50 7.20 36.00 36.00 CD5AXA042000
10.50 7.20 35.80 36.00 CD5AXA043000
10.50 7.20 35.80 36.00 CD5AXW036000
10.50 7.20 35.80 35.80 CD5AXW042000
10.50 7.20 35.80 36.00 CD5AXW043000
10.50 7.20 35.80 36.00 CD5BXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 7.20 35.80 36.00 CD3AXA036000
10.50 7.20 36.00 36.00 CD3AXA042000
10.50 7.20 35.80 36.00 CD3BXA036000
10.50 7.20 36.00 36.00 CD3BXA042000
10.50 7.20 35.40 35.60 CE3AXA036000
10.50 7.20 36.20 36.00 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 81: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/81.jpg)
38YKC04230 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.00 10.00 7.20 43.00 42.00 FA4ANB042000
11.00 11.00 7.50 43.50 42.00 FA4ANB048000
10.00 10.00 7.20 43.00 42.00 FA4ANF042000
11.00 11.00 7.50 43.50 42.00 FA4ANF048000
10.00 10.00 7.20 43.00 42.00 FB4ANB042000
11.00 11.00 7.50 43.50 42.00 FB4ANB048000
10.00 10.00 7.20 43.00 42.00 FB4ANF042000
10.50 10.50 7.50 43.50 42.00 FB4ANF048000
10.00 7.20 43.00 42.00 FC4BNB042000
10.50 7.50 43.50 42.00 FC4BNB048000
10.50 7.60 44.00 43.00 FC4BNF038000
10.00 7.20 43.00 42.00 FC4BNF042000
10.50 7.50 43.50 42.00 FC4BNF048000
10.50 7.20 43.00 42.00 FG3AAA048000
11.00 7.60 42.00 42.00 FK4BNF003000
11.00 8.00 43.50 43.00 FK4BNF005000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorKSAHS0701AAA
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorKSAHS0701AAA
Winter Start ControlN/A
Coastal FilterKAACF0401MED
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketKSASH1201COP
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.50 7.20 42.50 41.50 CC5AXA042000
10.00 7.20 42.50 41.50 CC5AXA043000
10.00 7.20 42.00 41.00 CC5AXC048000
10.00 7.20 42.00 41.00 CC5AXW042000
10.00 7.20 42.50 41.50 CC5AXW043000
10.00 7.20 42.50 41.50 CC5AXW048000
10.50 7.20 42.50 41.50 CD5AXA042000
10.00 7.20 42.50 41.50 CD5AXA043000
10.50 7.20 42.50 41.50 CD5AXA048000
10.00 7.20 42.00 41.00 CD5AXC048000
10.00 7.20 42.00 41.00 CD5AXW042000
10.00 7.20 42.50 41.50 CD5AXW043000
10.00 7.20 42.50 41.50 CD5AXW048000
10.50 7.20 42.50 41.50 CD5BXA042000
10.00 7.20 42.50 41.50 CD5BXA043000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.50 7.20 42.50 41.50 CD3AXA042000
10.50 7.20 42.50 41.50 CD3AXA048000
10.50 7.20 42.50 41.50 CD3BXA042000
10.50 7.20 42.50 41.50 CD3BXA048000
10.50 7.20 43.00 42.00 CE3AXA042000
10.50 7.20 43.00 42.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 82: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/82.jpg)
38YKC04830 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.50 10.50 7.80 50.00 46.00 FA4ANB048000
10.50 10.50 8.00 50.50 47.50 FA4ANB060000
10.50 10.50 7.80 50.00 46.00 FA4ANF048000
10.50 10.50 8.00 50.50 47.50 FA4ANF060000
10.50 10.50 7.80 50.00 46.00 FB4ANB048000
10.50 10.50 8.00 50.50 47.50 FB4ANB060000
11.00 11.00 8.20 50.50 48.50 FB4ANB070000
10.50 10.50 7.80 50.00 46.00 FB4ANF048000
10.50 10.50 8.00 50.50 47.50 FB4ANF060000
10.50 7.80 50.00 46.00 FC4BNB048000
11.00 8.20 50.00 48.00 FC4BNB054000
10.50 8.00 50.50 47.50 FC4BNB060000
11.00 8.20 50.50 48.50 FC4BNB070000
10.50 7.80 50.00 46.00 FC4BNF048000
10.50 8.00 50.50 47.50 FC4BNF060000
10.20 10.50 7.50 49.50 45.50 FG3AAA048000
10.70 11.00 7.50 49.50 47.00 FG3AAA060000
11.50 8.50 49.50 49.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Coastal FilterKAACF0401MED
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketKSASH1701COP
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.30 10.60 7.50 49.50 46.00 CC5AXA060000
10.20 10.50 7.50 49.00 45.00 CC5AXC048000
10.20 10.50 7.50 49.00 45.50 CC5AXW048000
10.70 11.00 8.00 49.50 47.00 CC5AXW060000
10.20 10.50 7.50 49.50 45.50 CD5AXA048000
10.30 10.60 7.50 49.50 46.00 CD5AXA060000
10.20 10.50 7.50 49.00 45.00 CD5AXC048000
10.20 10.50 7.50 49.00 45.50 CD5AXW048000
10.70 11.00 8.00 49.50 47.00 CD5AXW060000
10.20 10.50 7.50 49.50 45.50 CD5BXA048000
10.30 10.60 7.50 49.50 46.00 CD5BXA060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 10.50 7.50 49.50 45.50 CD3AXA048000
10.30 10.60 7.50 49.00 46.00 CD3AXA060000
10.20 10.50 7.50 49.50 45.50 CD3BXA048000
10.30 10.60 7.50 49.00 46.00 CD3BXA060000
10.30 10.60 7.50 49.50 46.00 CE3AXA048000
10.70 11.00 8.00 49.50 47.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 83: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/83.jpg)
38YKC06030 (80 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS10.60 10.60 7.60 61.00 56.50 FA4ANB060000
10.60 10.60 7.60 61.00 56.50 FA4ANF060000
10.60 10.60 7.60 61.00 56.50 FB4ANB060000
11.00 11.00 8.00 61.00 58.00 FB4ANB070000
10.60 10.60 7.60 61.00 56.50 FB4ANF060000
10.60 7.60 61.00 56.50 FC4BNB060000
11.00 8.00 61.00 58.00 FC4BNB070000
10.60 7.60 61.00 56.50 FC4BNF060000
10.60 11.00 7.50 59.50 56.00 FG3AAA060000
11.00 8.00 60.50 57.50 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
LLSKHALS0101LLS
TDRKAATD0101TDR
TXV (HSO)KHATX1401HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Coastal FilterKAACF0401MED
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketKSASH1701COP
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.20 10.60 7.20 59.00 54.50 CC5AXA060000
10.60 11.00 7.50 59.50 56.00 CC5AXW060000
10.20 10.60 7.20 59.00 54.50 CD5AXA060000
10.60 11.00 7.50 59.50 56.00 CD5AXW060000
10.20 10.60 7.20 59.00 54.50 CD5BXA060000
10.60 11.00 7.50 59.50 56.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.20 10.60 7.20 59.00 54.50 CD3AXA060000
10.20 10.60 7.20 59.00 54.50 CD3BXA060000
10.60 11.00 7.50 60.00 57.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 84: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/84.jpg)
38YMA01832 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.00 18.00 18.00 FA4ANF024000
11.50 11.50 7.00 18.00 18.00 FA4ANF030000
11.00 11.00 7.00 18.00 18.00 FB4ANF024000
11.50 11.50 7.00 18.00 18.00 FB4ANF030000
11.00 7.00 18.00 18.00 FC4BNF024000
11.50 7.00 18.00 18.00 FC4BNF030000
11.00 11.20 6.80 17.60 17.70 FD3ANA024000
10.70 10.70 6.80 17.20 17.00 FF1ANA018000
11.00 11.20 7.00 18.00 18.00 FF1ANA024000
10.70 10.70 6.80 17.20 17.00 FF1BNA018000
11.00 11.20 7.00 18.00 18.00 FF1BNA024000
10.70 11.00 6.80 17.70 17.70 FG3AAA024000
12.50 7.20 17.60 18.40 FK4BNF001000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. Size dependent on home duct size.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers5
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers5
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorStandard
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorStandard
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow10.70 11.00 6.80 17.70 17.80 CC5AXA024000
10.70 11.00 6.80 17.70 17.80 CD5AXA024000
10.70 11.00 6.80 17.70 17.80 CD5BXA024000
11.00 11.20 6.80 17.80 18.00 CF5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.70 11.00 6.80 17.70 17.80 CD3AXA024000
10.70 11.00 6.80 17.70 17.80 CD3BXA024000
11.00 11.20 6.80 17.80 18.00 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 85: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/85.jpg)
38YMA02432 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.20 22.40 23.00 FA4ANF024000
11.50 11.50 7.20 22.40 23.80 FA4ANF030000
11.00 11.00 7.20 22.40 23.00 FB4ANF024000
11.50 11.50 7.20 22.40 23.80 FB4ANF030000
11.00 7.20 22.40 23.20 FC4BNF024000
11.50 7.20 22.40 23.80 FC4BNF030000
10.70 11.00 7.00 22.00 23.00 FD3ANA024000
11.10 11.50 7.20 22.60 23.80 FD3ANA030000
10.70 11.00 7.20 22.40 23.20 FF1ANA024000
11.10 11.50 7.20 22.80 24.00 FF1ANA030000
10.70 11.00 7.20 22.40 23.20 FF1BNA024000
11.10 11.50 7.20 22.80 24.00 FF1BNA030000
10.70 11.00 7.00 22.00 23.00 FG3AAA024000
12.50 7.40 22.00 24.00 FK4BNF001000
12.60 7.50 22.00 24.20 FK4BNF002000
12.80 7.50 21.80 24.00 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorStandard
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorStandard
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow10.70 11.00 7.00 22.20 23.20 CC5AXA024000
11.00 11.50 7.00 22.20 23.60 CC5AXA030000
11.00 11.50 7.00 22.20 23.60 CC5AXW030000
10.70 11.00 7.00 22.20 23.20 CD5AXA024000
11.00 11.50 7.00 22.20 23.60 CD5AXA030000
11.00 11.50 7.00 22.20 23.60 CD5AXW030000
10.70 11.00 7.00 22.20 23.20 CD5BXA024000
11.00 11.50 7.00 22.20 23.60 CD5BXA030000
11.00 11.50 7.00 22.20 23.60 CD5BXW030000
11.00 11.30 7.00 22.20 23.40 CF5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal10.70 11.00 7.00 22.20 23.20 CD3AXA024000
11.00 11.50 7.00 22.20 23.60 CD3AXA030000
10.70 11.00 7.00 22.20 23.20 CD3BXA024000
11.00 11.50 7.00 22.20 23.60 CD3BXA030000
11.00 11.30 7.00 22.20 23.60 CE3AXA024000
11.00 11.50 7.20 22.60 23.80 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 86: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/86.jpg)
38YMA03032 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.60 30.00 29.00 FA4ANF030000
11.00 11.00 7.50 30.00 29.20 FA4ANF036000
11.00 11.00 7.60 30.00 29.00 FB4ANF030000
11.00 11.00 7.50 30.00 29.20 FB4ANF036000
11.00 7.60 30.00 29.00 FC4BNF030000
11.00 7.50 30.00 29.20 FC4BNF036000
11.00 11.10 7.60 30.00 29.00 FD3ANA030000
11.00 11.10 7.60 30.00 29.00 FF1ANA030000
11.00 11.10 7.60 30.00 29.00 FF1BNA030000
11.00 11.10 7.60 30.00 29.20 FG3AAA036000
11.50 7.60 29.60 29.20 FK4BNF001000
11.60 7.80 30.00 29.20 FK4BNF002000
11.80 7.80 29.20 29.40 FK4BNF003000
12.00 8.00 30.00 29.60 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorStandard
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorStandard
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 11.10 7.50 29.60 29.00 CC5AXA030000
11.30 11.50 7.60 30.00 29.40 CC5AXA036000
11.00 11.10 7.50 29.60 29.00 CC5AXW030000
11.00 11.10 7.50 29.60 29.00 CD5AXA030000
11.30 11.50 7.60 30.00 29.40 CD5AXA036000
11.00 11.10 7.50 29.60 29.00 CD5AXW030000
11.30 11.50 7.60 30.00 29.40 CD5AXW036000
11.00 11.10 7.50 29.60 29.00 CD5BXA030000
11.30 11.50 7.60 30.00 29.40 CD5BXA036000
11.00 11.10 7.50 29.60 29.00 CD5BXW030000
11.30 11.50 7.60 30.00 29.40 CD5BXW036000
11.30 11.50 7.60 30.00 29.40 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 11.10 7.50 29.60 29.00 CD3AXA030000
11.30 11.50 7.60 30.00 29.40 CD3AXA036000
11.00 11.10 7.50 29.60 29.00 CD3BXA030000
11.30 11.50 7.60 30.00 29.40 CD3BXA036000
11.00 11.10 7.60 30.00 29.00 CE3AXA030000
11.30 11.50 7.60 30.00 29.40 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 87: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/87.jpg)
38YMA03632 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.00 11.00 7.40 36.00 35.20 FA4ANB042000
10.50 10.50 7.20 35.80 34.40 FA4ANF036000
11.00 11.00 7.40 36.00 35.20 FA4ANF042000
11.00 11.00 7.40 36.00 35.20 FB4ANB042000
10.50 10.50 7.20 35.80 34.40 FB4ANF036000
11.00 11.00 7.40 36.00 35.20 FB4ANF042000
11.00 7.40 36.00 35.20 FC4BNB042000
10.50 7.20 35.80 34.40 FC4BNF036000
11.00 7.40 36.00 35.20 FC4BNF042000
10.50 10.60 7.30 35.20 34.20 FG3AAA036000
11.00 7.20 34.60 34.00 FK4BNF001000
11.00 7.40 35.20 34.00 FK4BNF002000
11.60 7.50 34.00 34.60 FK4BNF003000
11.50 7.60 35.20 34.40 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterStandard
Cycle ProtectorKSACY0101AAA
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorStandard
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorStandard
Cycle ProtectorKSACY0101AAA
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchKSAHI0201HPS
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.00 11.10 7.40 35.60 35.00 CC5AXA036000
11.00 11.10 7.40 35.60 35.00 CC5AXA042000
10.80 11.00 7.30 35.40 34.60 CC5AXW042000
11.00 11.10 7.40 35.60 35.00 CD5AXA036000
11.00 11.10 7.40 35.60 35.00 CD5AXA042000
10.80 11.00 7.30 35.40 34.60 CD5AXW042000
11.00 11.10 7.40 35.60 35.00 CD5BXA036000
11.00 11.10 7.40 35.60 35.00 CD5BXA042000
11.00 11.10 7.40 35.60 35.00 CD5BXW036000
10.80 11.00 7.30 35.40 34.60 CD5BXW042000
10.80 11.00 7.30 35.60 34.80 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.00 11.10 7.40 35.60 35.00 CD3AXA036000
11.00 11.10 7.40 35.60 35.00 CD3AXA042000
11.00 11.10 7.40 35.60 35.00 CD3BXA036000
11.00 11.10 7.40 35.60 35.00 CD3BXA042000
10.80 11.00 7.30 35.40 34.60 CE3AXA036000
10.80 11.00 7.40 35.60 34.80 CE3AXA042000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 88: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/88.jpg)
38YMA04231 (78 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.20 11.20 7.70 41.50 39.50 FA4ANB042000
11.50 11.50 8.00 42.00 40.00 FA4ANB048000
11.20 11.20 7.70 41.50 39.50 FA4ANF042000
11.50 11.50 8.00 42.00 40.00 FA4ANF048000
11.20 11.20 7.70 41.50 39.50 FB4ANB042000
11.50 11.50 8.00 42.00 40.00 FB4ANB048000
11.20 11.20 7.70 41.50 39.50 FB4ANF042000
11.50 11.50 8.00 42.00 40.00 FB4ANF048000
11.20 7.70 41.50 39.50 FC4BNB042000
11.50 8.00 42.00 40.00 FC4BNB048000
11.20 7.70 41.50 39.50 FC4BNF042000
11.50 8.00 42.00 40.00 FC4BNF048000
11.30 11.50 7.80 41.50 39.50 FG3AAA048000
12.50 8.20 41.00 40.50 FK4BNB005000
12.80 8.50 41.00 40.50 FK4BNB006000
12.10 7.80 40.50 39.50 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0504 P299-0506 P299-0508
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.30 11.50 7.70 41.00 39.00 CC5AXA042000
11.20 11.50 7.50 41.00 39.00 CC5AXC048000
11.20 11.50 7.50 41.00 39.00 CC5AXW042000
11.20 11.50 7.80 41.50 39.00 CC5AXW048000
11.30 11.50 7.70 41.00 39.00 CD5AXA042000
11.20 11.50 7.50 41.00 39.00 CD5AXC048000
11.20 11.50 7.50 41.00 39.00 CD5AXW042000
11.20 11.50 7.80 41.50 39.00 CD5AXW048000
11.30 11.50 7.70 41.00 39.00 CD5BXA042000
11.30 11.50 7.80 41.50 39.00 CD5BXA048000
11.20 11.50 7.50 41.00 39.00 CD5BXC048000
11.20 11.50 7.50 41.00 39.00 CD5BXW042000
11.20 11.50 7.80 41.50 39.00 CD5BXW048000
11.20 11.50 7.80 41.50 39.50 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.20 11.50 7.70 41.00 39.00 CD3AXA042000
11.20 11.50 7.80 41.50 39.00 CD3AXA048000
11.20 11.50 7.70 41.00 39.00 CD3BXA042000
11.20 11.50 7.80 41.50 39.00 CD3BXA048000
11.10 11.30 7.70 41.50 39.00 CE3AXA042000
11.30 11.50 7.80 41.50 40.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 89: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/89.jpg)
38YMA04831 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.30 11.30 7.20 47.50 46.50 FA4ANB048000
11.20 11.20 7.50 48.00 47.50 FA4ANB060000
11.30 11.30 7.20 47.50 46.50 FA4ANF048000
11.20 11.20 7.50 48.00 47.50 FA4ANF060000
11.30 11.30 7.20 47.50 46.50 FB4ANB048000
11.20 11.20 7.50 48.00 47.50 FB4ANB060000
11.30 11.30 7.20 47.50 46.50 FB4ANF048000
11.20 11.20 7.50 48.00 47.50 FB4ANF060000
11.30 7.20 47.50 46.50 FC4BNB048000
11.30 7.50 48.00 47.00 FC4BNB060000
11.30 7.20 47.50 46.50 FC4BNF048000
11.30 7.50 48.00 47.00 FC4BNF060000
11.10 11.30 7.20 47.50 46.50 FG3AAA048000
11.30 11.50 7.50 47.50 47.00 FG3AAA060000
12.50 8.00 47.00 48.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric BypassDAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector Board
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support FeetKSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.10 11.20 7.00 47.00 46.00 CC5AXA060000
11.00 11.20 6.80 46.00 45.00 CC5AXC048000
11.10 11.20 7.20 47.00 45.50 CC5AXW048000
11.30 11.50 7.30 47.50 47.00 CC5AXW060000
11.10 11.20 7.00 47.00 46.00 CD5AXA060000
11.00 11.20 6.80 46.00 45.00 CD5AXC048000
11.10 11.20 7.20 47.00 45.50 CD5AXW048000
11.30 11.50 7.30 47.50 47.00 CD5AXW060000
11.10 11.20 7.20 47.00 46.00 CD5BXA048000
11.10 11.20 7.00 47.00 46.00 CD5BXA060000
11.00 11.20 6.80 46.00 45.00 CD5BXC048000
11.10 11.20 7.20 47.00 45.50 CD5BXW048000
11.30 11.50 7.30 47.50 47.00 CD5BXW060000
11.20 11.40 7.00 46.50 46.00 CF5AXA048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.10 11.20 7.20 47.00 46.00 CD3AXA048000
11.10 11.20 7.00 47.00 46.00 CD3AXA060000
11.10 11.20 7.20 47.00 46.00 CD3BXA048000
11.10 11.20 7.00 47.00 46.00 CD3BXA060000
11.30 11.50 7.20 47.00 46.50 CE3AXA048000
11.30 11.50 7.30 47.50 47.00 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 90: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/90.jpg)
38YRA01831 (70 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.70 6.80 17.00 17.50 FA4ANC018000
12.20 7.20 17.50 18.00 FA4ANC024000
11.70 6.80 17.00 17.50 FA4ANF018000
12.20 7.20 17.50 18.00 FA4ANF024000
11.70 6.80 17.00 17.50 FB4ANC018000
12.20 7.20 17.50 18.00 FB4ANC024000
11.70 6.80 17.00 17.50 FB4ANF018000
12.20 7.20 17.50 18.00 FB4ANF024000
12.20 7.20 17.50 18.00 FC4BNF024000
11.70 6.80 17.00 17.50 FD3ANA018000
12.70 7.00 17.00 18.00 FD3ANA024000
12.50 7.00 17.00 17.50 FF1BNA018000
12.70 7.20 17.50 18.50 FF1BNA024000
12.20 7.00 17.00 18.00 FG3ANA024000
14.00 7.50 17.00 19.00 FK4BNF001000
14.50 8.00 17.00 19.00 FK4BNF002000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
5. Thermostat not needed if Carrier Comfort Zone kit is purchased.6. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.7. See price pages for complete listing of line sets.8. Size dependent on home duct size.9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass8
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers8
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers8
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX0901HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 6.80 17.00 17.50 CC5AXA018000
12.50 7.00 17.50 18.00 CC5AXA024000
12.50 7.00 17.50 18.00 CC5AXW024000
12.00 6.80 17.00 17.50 CD5AXA018000
12.50 7.00 17.50 18.00 CD5AXA024000
12.50 7.00 17.50 18.00 CD5AXW024000
12.00 6.80 17.00 17.50 CD5BXA018000
12.50 7.00 17.50 18.00 CD5BXA024000
12.50 7.00 17.50 18.00 CD5BXW024000
12.50 7.00 17.50 18.00 CF5AXA024000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 6.80 17.00 17.50 CD3AXA018000
12.50 7.00 17.50 18.00 CD3AXA024000
12.00 6.80 17.00 17.50 CD3BXA018000
12.50 7.00 17.50 18.00 CD3BXA024000
12.50 7.00 17.50 18.00 CE3AXA024000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING4 THERMOSTAT5
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE6
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 91: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/91.jpg)
38YRA02430 (70 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.80 7.70 24.00 22.40 FA4ANF024000
12.10 7.80 24.00 22.80 FA4ANF030000
11.80 7.70 24.00 22.40 FB4ANF024000
12.10 7.80 24.00 22.80 FB4ANF030000
11.80 7.70 24.00 22.40 FC4BNF024000
12.00 7.80 24.00 22.80 FC4BNF030000
12.10 8.00 24.00 23.20 FC4BNF033000
11.80 7.50 24.00 21.80 FD3ANA024000
11.80 7.70 24.00 22.60 FD3ANA030000
11.80 7.70 24.00 22.40 FF1ANA024000
12.00 7.80 24.00 22.80 FF1ANA030000
11.80 7.70 24.00 22.40 FF1BNA024000
12.00 7.80 24.00 22.80 FF1BNA030000
11.50 7.50 24.00 21.80 FG3AAA024000
13.00 8.20 23.80 23.40 FK4BNF001000
13.50 8.50 24.00 23.60 FK4BNF002000
14.00 8.50 23.60 23.60 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. Size dependent on home duct size.7. See price pages for complete listing of line sets.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass6
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers6
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers6
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow11.70 7.50 24.00 22.20 CC5AXA024000
11.70 7.50 24.00 22.40 CC5AXA030000
12.00 7.80 24.20 23.00 CC5AXA036000
11.70 7.50 24.00 22.40 CC5AXW030000
11.70 7.50 24.00 22.20 CD5AXA024000
11.70 7.50 24.00 22.40 CD5AXA030000
12.00 7.80 24.20 23.00 CD5AXA036000
11.70 7.50 24.00 22.40 CD5AXW030000
12.00 7.80 24.20 23.00 CD5AXW036000
11.70 7.50 24.00 22.20 CD5BXA024000
11.70 7.50 24.00 22.40 CD5BXA030000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.70 7.50 24.00 22.20 CD3AXA024000
11.70 7.50 24.00 22.40 CD3AXA030000
12.00 7.80 24.20 23.00 CD3AXA036000
11.70 7.50 24.00 22.20 CD3BXA024000
11.70 7.50 24.00 22.40 CD3BXA030000
12.00 7.80 24.20 23.00 CD3BXA036000
11.70 7.50 24.00 22.20 CE3AXA024000
12.00 7.60 24.00 22.60 CE3AXA030000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET7SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 92: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/92.jpg)
38YRA03030 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.30 7.70 30.00 28.00 FA4ANF030000
12.10 7.70 30.00 28.40 FA4ANF036000
12.30 7.70 30.00 28.00 FB4ANF030000
12.10 7.70 30.00 28.40 FB4ANF036000
12.30 7.70 30.00 28.00 FC4BNF030000
12.50 8.00 30.00 28.80 FC4BNF033000
12.10 7.70 30.00 28.40 FC4BNF036000
12.10 7.70 30.00 28.00 FD3ANA030000
12.20 7.70 30.00 28.20 FF1ANA030000
12.20 7.70 30.00 28.20 FF1BNA030000
12.20 7.70 30.00 28.20 FG3AAA036000
13.00 8.00 30.00 29.00 FK4BNF001000
13.50 8.20 30.00 29.20 FK4BNF002000
14.00 8.20 29.80 29.60 FK4BNF003000
13.50 8.50 30.00 29.80 FK4BNF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 7.50 30.00 27.80 CC5AXA030000
12.50 7.70 30.00 28.60 CC5AXA036000
12.00 7.50 30.00 27.80 CC5AXW030000
12.00 7.50 30.00 27.80 CD5AXA030000
12.50 7.70 30.00 28.60 CD5AXA036000
12.00 7.50 30.00 27.80 CD5AXW030000
12.50 7.70 30.00 28.60 CD5AXW036000
12.00 7.50 30.00 27.80 CD5BXA030000
12.50 7.70 30.00 28.60 CD5BXA036000
12.00 7.50 30.00 27.80 CD5BXW030000
12.50 7.70 30.00 28.60 CD5BXW036000
12.50 7.70 30.00 28.60 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,
58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 7.50 30.00 27.80 CD3AXA030000
12.50 7.70 30.00 28.60 CD3AXA036000
12.00 7.50 30.00 27.80 CD3BXA030000
12.50 7.70 30.00 28.60 CD3BXA036000
12.00 7.70 30.00 28.00 CE3AXA030000
12.50 7.70 30.00 28.40 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 93: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/93.jpg)
38YRA03630 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.00 7.80 36.00 34.20 FA4ANB042000
11.50 7.60 36.00 33.60 FA4ANF036000
12.00 7.80 36.00 34.20 FA4ANF042000
12.00 7.80 36.00 34.20 FB4ANB042000
11.50 7.60 36.00 33.60 FB4ANF036000
12.00 7.80 36.00 34.20 FB4ANF042000
12.00 7.80 36.00 34.20 FC4BNB042000
11.70 7.80 36.00 34.20 FC4BNF033000
11.50 7.60 36.00 33.60 FC4BNF036000
12.00 7.80 36.00 34.20 FC4BNF042000
11.50 7.60 36.00 33.40 FG3AAA036000
12.00 7.80 36.00 33.80 FK4BNF001000
12.00 7.80 36.00 33.80 FK4BNF002000
13.00 8.00 35.60 34.80 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programamble
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 7.70 36.00 34.00 CC5AXA036000
12.00 7.70 36.00 34.00 CC5AXA042000
12.00 7.70 36.00 34.00 CC5AXA043000
12.00 7.70 36.00 33.80 CC5AXW042000
12.00 7.70 36.00 34.00 CC5AXW043000
12.00 7.70 36.00 34.00 CD5AXA036000
12.00 7.70 36.00 34.00 CD5AXA042000
12.00 7.70 36.00 34.00 CD5AXA043000
12.00 7.70 36.00 34.00 CD5AXW036000
12.00 7.70 36.00 33.80 CD5AXW042000
12.00 7.70 36.00 34.00 CD5AXW043000
12.00 7.70 36.00 34.00 CD5BXA036000
12.00 7.70 36.00 34.00 CD5BXA042000
12.00 7.70 36.00 34.00 CD5BXA043000
12.00 7.70 36.00 34.00 CD5BXW036000
12.00 7.70 36.00 33.80 CD5BXW042000
12.00 7.70 36.00 34.00 CD5BXW043000
12.00 7.70 36.00 34.00 CF5AXA036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,58VCA, 58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 7.70 36.00 34.00 CD3AXA036000
12.00 7.70 36.00 34.00 CD3AXA042000
12.00 7.70 36.00 34.00 CD3BXA036000
12.00 7.70 36.00 34.00 CD3BXA042000
11.70 7.60 36.00 33.60 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 94: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/94.jpg)
38YRA04231 (72 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.00 7.50 41.00 39.00 FA4ANB042000
12.50 7.70 41.00 39.50 FA4ANB048000
12.00 7.50 41.00 39.00 FA4ANF042000
12.50 7.70 41.00 39.50 FA4ANF048000
12.00 7.50 41.00 39.00 FB4ANB042000
12.50 7.70 41.00 39.50 FB4ANB048000
12.00 7.50 41.00 39.00 FB4ANF042000
12.50 7.70 41.00 39.50 FB4ANF048000
12.00 7.50 41.00 39.00 FC4BNB042000
12.50 7.70 41.00 39.50 FC4BNB048000
12.50 7.80 41.00 40.50 FC4BNF038000
12.00 7.50 41.00 39.00 FC4BNF042000
12.50 7.70 41.00 39.50 FC4BNF048000
12.00 7.50 41.00 39.00 FG3AAA048000
13.50 8.20 41.00 41.50 FK4BNB005000
13.00 7.80 41.00 39.50 FK4BNF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 7.50 41.00 39.00 CC5AXA042000
12.00 7.50 41.00 39.00 CC5AXA043000
12.00 7.30 41.00 38.50 CC5AXC048000
12.00 7.40 41.00 38.50 CC5AXW042000
12.00 7.50 41.00 39.00 CC5AXW043000
12.50 7.50 41.00 39.00 CC5AXW048000
12.00 7.50 41.00 39.00 CD5AXA042000
12.00 7.50 41.00 39.00 CD5AXA043000
12.50 7.50 41.00 39.00 CD5AXA048000
12.50 7.30 41.00 38.50 CD5AXC048000
12.00 7.40 41.00 38.50 CD5AXW042000
12.00 7.50 41.00 39.00 CD5AXW043000
12.50 7.50 41.00 39.00 CD5AXW048000
12.00 7.50 41.00 39.00 CD5BXA042000
12.00 7.50 41.00 39.00 CD5BXA043000
12.50 7.50 41.00 39.00 CD5BXA048000
12.50 7.30 41.00 38.50 CD5BXC048000
12.00 7.40 41.00 38.50 CD5BXW042000
12.00 7.50 41.00 39.00 CD5BXW043000
12.50 7.50 41.00 39.00 CD5BXW048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.00 7.40 41.00 39.00 CD3AXA042000
12.50 7.50 41.00 39.00 CD3AXA048000
12.00 7.40 41.00 39.00 CD3BXA042000
12.50 7.50 41.00 39.00 CD3BXA048000
12.00 7.50 41.00 39.50 CE3AXA042000
12.50 7.50 41.00 39.50 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 95: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/95.jpg)
38YRA04830 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.40 7.40 49.50 45.50 FA4ANB048000
11.50 7.50 50.00 47.00 FA4ANB060000
11.40 7.40 49.50 45.50 FA4ANF048000
11.50 7.50 50.00 47.00 FA4ANF060000
11.40 7.40 49.50 45.50 FB4ANB048000
11.50 7.50 50.00 47.00 FB4ANB060000
12.00 8.00 50.00 47.50 FB4ANB070000
11.40 7.40 49.50 45.50 FB4ANF048000
11.50 7.50 50.00 47.00 FB4ANF060000
11.40 7.40 49.50 45.50 FC4BNB048000
12.10 8.00 50.00 48.00 FC4BNB054000
11.50 7.50 50.00 47.00 FC4BNB060000
12.00 8.00 50.00 47.50 FC4BNB070000
11.40 7.40 49.50 45.50 FC4BNF048000
11.50 7.50 50.00 47.00 FC4BNF060000
11.40 7.20 49.00 45.00 FG3AAA048000
11.70 7.30 49.00 46.00 FG3AAA060000
13.00 8.10 49.00 48.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 7.10 48.50 45.00 CC5AXA060000
11.30 6.90 48.00 44.50 CC5AXC048000
11.40 7.20 48.50 45.00 CC5AXW048000
11.80 7.50 49.00 46.50 CC5AXW060000
11.40 7.20 48.50 45.00 CD5AXA048000
11.50 7.10 48.50 45.00 CD5AXA060000
11.30 6.90 48.00 44.50 CD5AXC048000
11.40 7.20 48.50 45.00 CD5AXW048000
11.80 7.50 49.00 46.50 CD5AXW060000
11.40 7.20 48.50 45.00 CD5BXA048000
11.50 7.10 48.50 45.00 CD5BXA060000
11.30 6.90 48.00 44.50 CD5BXC048000
11.40 7.20 48.50 45.00 CD5BXW048000
11.80 7.50 49.00 46.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.40 7.20 48.50 45.00 CD3AXA048000
11.50 7.10 48.50 45.00 CD3AXA060000
11.40 7.20 48.50 45.00 CD3BXA048000
11.50 7.10 48.50 45.00 CD3BXA060000
11.60 7.30 49.00 45.50 CE3AXA048000
12.00 7.50 49.00 46.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 96: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/96.jpg)
38YRA06030 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.50 7.80 61.00 57.50 FA4ANB060000
11.50 7.80 61.00 57.50 FA4ANF060000
11.50 7.80 61.00 57.50 FB4ANB060000
12.00 8.00 61.00 58.50 FB4ANB070000
11.50 7.80 61.00 57.50 FB4ANF060000
11.50 7.80 61.00 57.50 FC4BNB060000
12.00 8.00 61.00 58.50 FC4BNB070000
11.50 7.80 61.00 57.50 FC4BNF060000
11.50 7.50 61.00 56.50 FG3AAA060000
12.50 8.30 61.00 59.00 FK4BNB006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Enhancements include Time Delay Relay (TDR) or Liquid Line Solenoid (LLS) or Thermostatic Expansion Valve (TXV). Depending onapplication, further enhancement may or may not be achieved by combining any 2 of the 3 accessories.
2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.10. Fan motor with ball bearings required.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1401HSO
Crankcase HeaterStandard
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Ball Bearing FanMotor
HC38GE230
Crankcase HeaterStandard
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
MotorMaster10
32LT660004
Start Assist-PTCKAACS0201PTC
Start CapacitorKSAHS0401AAA
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237 P152-4147
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0306MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20618-06SB(15 FT )
P850-30618-06SB(20 FT )
P850-40618-06SB(25 FT )
P850-50618-06SB(30 FT )
P850-60618-06SB(35 FT )
P850-70618-06SB(40 FT )
P850-90618-06SB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.50 7.30 61.00 55.50 CC5AXA060000
11.50 7.70 61.00 56.50 CC5AXW060000
11.50 7.30 61.00 55.50 CD5AXA060000
11.50 7.70 61.00 56.50 CD5AXW060000
11.50 7.30 61.00 55.50 CD5BXA060000
11.50 7.70 61.00 56.50 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal11.50 7.30 61.00 55.50 CD3AXA060000
11.50 7.30 61.00 55.50 CD3BXA060000
12.00 7.70 61.00 57.50 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6SEER
SEER W/ENHANCE1 HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 97: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/97.jpg)
38YS02430 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS13.50 9.00 23.60 23.00 FK4ANF002000
13.70 9.00 24.00 23.00 FK4ANF003000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Unit requires TXV (HSO) to meet listed SEER ratings; TXV field installed.2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1001HSO
REQUIRED
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20610-06PEB(15 FT )
P850-30610-06PEB(20 FT )
P850-40610-06PEB(25 FT )
P850-50610-06PEB(30 FT )
P850-60610-06PEB(35 FT )
P850-70610-06PEB(40 FT )
P850-90610-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.20 8.30 24.00 22.40 CC5AXA036000
12.20 8.30 24.00 22.40 CD5AXA036000
12.20 8.30 24.00 22.40 CD5AXW036000
12.20 8.30 24.00 22.40 CD5BXA036000
12.20 8.30 24.00 22.40 CD5BXW036000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.20 8.30 24.00 22.40 CD3AXA036000
12.20 8.30 24.00 22.40 CD3BXA036000
12.10 8.20 24.00 22.20 CE3AXA036000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6
SEER1
W/TXVSEER W/
TXV & TDR HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 98: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/98.jpg)
38YS03030 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS14.70 9.05 32.00 30.00 FK4ANF003000
15.00 9.00 31.80 30.40 FK4ANF004000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Unit requires TXV (HSO) to meet listed SEER ratings; TXV field installed.2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1101HSO
REQUIRED
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow13.50 8.20 32.00 30.00 CC5AXA042000
13.30 8.10 32.00 29.60 CC5AXW042000
13.50 8.20 32.00 30.00 CD5AXA042000
13.30 8.10 32.00 29.60 CD5AXW042000
13.50 8.20 32.00 30.00 CD5BXA042000
13.30 8.10 32.00 29.60 CD5BXW042000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal13.30 8.10 32.00 29.60 CD3AXA042000
13.30 8.10 32.00 29.60 CD3BXA042000
13.60 8.30 32.00 30.00 CE3AXA048000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6
SEER1
W/TXVSEER W/
TXV & TDR HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 99: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/99.jpg)
38YS03630 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS13.80 9.00 36.00 35.20 FK4ANF005000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Unit requires TXV (HSO) to meet listed SEER ratings; TXV field installed.2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
REQUIRED
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8083S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8083S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20612-06PEB( 15 FT)
P850-30612-06PEB( 20 FT)
P850-40612-06PEB( 25 FT)
P850-50612-06PEB( 30 FT)
P850-60612-06PEB( 35 FT)
P850-70612-06PEB( 40 FT)
P850-90612-06PEB( 50 FT)
FURNAN1
FURNACE COILS - Upflow/Downflow12.50 7.80 36.60 33.80 CC5AXW048000
12.50 7.80 36.60 33.80 CD5AXA048000
12.50 7.80 36.60 33.80 CD5AXW048000
12.50 7.80 36.60 33.80 CD5BXA048000
12.50 7.80 36.60 33.80 CD5BXW048000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
FURNAN3
FURNACE COILS - Horizontal12.50 7.80 36.60 33.80 CD3AXA048000
12.50 7.80 36.60 33.80 CD3BXA048000
13.00 8.00 36.40 34.40 CE3AXA060000
Furnan Blk 4
Horizontal58EFA, 58EJB∗,
58MCA∗, 58MVP∗,58MXA∗, 58RAV∗,58TMA∗, 58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6
SEER1
W/TXVSEER W/
TXV & TDR HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 100: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/100.jpg)
38YS04230 (74 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS12.00 12.00 8.40 43.00 40.50 FB4ANF070000
12.00 12.00 8.40 43.00 40.50 FB4ANM070000
13.20 8.80 42.00 41.00 FK4ANF006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1
Mechanical31MF-120---0
1. Unit requires TXV (HSO) to meet listed SEER ratings; TXV field installed.2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1201HSO
REQUIRED
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-3237
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0206MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0504 P299-0505 P299-0506
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow12.00 8.00 43.00 40.00 CC5AXW060000
12.00 8.00 43.00 40.00 CD5AXW060000
12.00 8.00 43.00 40.00 CD5BXW060000
Furnan Blk 2
Upflow58GFA, 58MCA∗,58MVP∗, 58MXA∗,58PAV∗, 58TUA∗,
58WAV∗
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6
SEER1
W/TXVSEER W/
TXV & TDR HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 101: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/101.jpg)
38YS04830 (76 dBA)
$ $ $ $ $ $ $ $
$
PRICE:
TOTAL SYSTEM:
$ $ $ $ $
FAN COILS11.80 11.80 8.40 50.00 45.50 FB4ANF070000
11.80 11.80 8.40 50.00 45.50 FB4ANM070000
12.50 8.70 49.00 46.50 FK4ANF006000
Comfort VentilatorVA3BAB015000 VA3BAB020000 VB5BAB015000 VB5BAB020000 VC5BAB015000 VC5BAB020000 VC5BAB027000
Duct Mounted31KAX012---1 31KAX016---1 31KAX020---1
Energy RecoveryVentilator
VL3AAA015000 VL3AAA020000
Grille Mounted31RX-010---1 31RX-016---1 31RX-020---1
Mechanical31MF-120---0
1. Unit requires TXV (HSO) to meet listed SEER ratings; TXV field installed.2. Humidifier sized based on relative humidity needs.3. Air cleaner sized based on system airflow.4. Thermostat not needed if Carrier Comfort Zone kit is purchased.5. See Residential Long-Lines Application Guide. Limited to 100 equivalent feet.6. See price pages for complete listing of line sets.7. Size dependent on home duct size.8. Other Carrier zoning accessories include: 90 Degree Actuator DAMPACT90DEG, 45 Degree Actuator DAMPACT45DEG, Command Center
ZONECZCCCARR, Comfort Zone I/O Center ZONEIOCENTCA, Comfort Zone I/O Board ZONEIOBDCARR, Home Access ModuleZONEHAMCAR4Z, Multi-damper Enabler ZONEMLTDMPEN, Duct Temperature Sensor ZONEDUCTTSEN, Fuse Pack ZONEFUSEPACK,Slip-In Dampers (Bottom Mount) DAMPSLB-----, and Slip-In Dampers (Side Mount) DAMPSLS-----.
9. A high-pressure switch must be used with the Dual Fuel Thermostat.
Barometric Bypass7
DAMPBAR08X14 DAMPBAR08X24
Carrier WeathermakerTwo Zone
ZONEKIT2ZCAR
Comfort ZoneZONEKIT4ZCAR
Four-Zone ControllerZONE4ZCONTCA
Four-Zone ControllerCover
ZONE4ZCONCOV
Rectangular Dampers7
DAMPREC08X10 DAMPREC08X14 DAMPREC08X18 DAMPREC08X24 DAMPREC10X10 DAMPREC10X14 DAMPREC10X18 DAMPREC10X24
Round Dampers7
DAMPRND06INC DAMPRND08INC DAMPRND10INC DAMPRND12INC DAMPRND14INC DAMPRND16INC
Smart SensorZONESMSENCAR
Smart SensorConnector BoardZONESMSENCBD
Smart Sensor PowerPack
ZONESMSENPPC
Auto Changeover7-Day Programmable9
TSTATCCPDF01-A TSTATCCPHP01-A
Auto ChangeoverNon-ProgrammableTSTATCCNHP01-A
Backplate forNon-Programmable
TSTATTSTATXXNBP01
Backplate forProgrammable TSTAT
TSTATXXPBP01
Manual ChangeoverNon-Programmable
--HH--07AT-215
Outdoor SensorTSTATCCSEN01
TDRKAATD0101TDR
TXV (HSO)KHATX1301HSO
REQUIRED
Crankcase HeaterKAACH1201AAA
Cycle ProtectorStandard
Filter DrierP504-8163S
LLSKHALS0101LLS
Start Assist-PTCN/A
Start CapacitorN/A
Crankcase HeaterKAACH1201AAA
Evap FreezeThermostat
KAAFT0101AAA
Isolation RelayKHAIR0101AAA
Low-AmbientControllerP251-0083
Start Assist-PTCN/A
Start CapacitorN/A
Winter Start ControlN/A
Cycle ProtectorStandard
Equipment PadP152-4147
Filter DrierP504-8163S
High-Pressure SwitchStandard
Low-Pressure SwitchStandard
Service AlarmKHASA0101AAA
Snow RackKHASS0306MPK
Sound BlanketStandard
Support Feet(Pump-ups)
KSASF0101AAA
WhipsP299-0754 P299-0756 P299-0758
P850-20614-06PEB(15 FT )
P850-30614-06PEB(20 FT )
P850-40614-06PEB(25 FT )
P850-50614-06PEB(30 FT )
P850-60614-06PEB(35 FT )
P850-70614-06PEB(40 FT )
P850-90614-06PEB(50 FT )
FURNAN1
FURNACE COILS - Upflow/Downflow11.70 8.00 50.00 44.50 CC5AXW060000
11.70 8.00 50.00 44.50 CD5AXW060000
11.70 8.00 50.00 44.50 CD5BXW060000
Furnan Blk 2
Downflow58DFA, 58MCA∗,58MVP∗, 58MXA∗,58RAV∗, 58TMA∗,
58ZAV∗
∗TDR standard.
RATINGS
INDOORUNIT FURNACE HUMIDIFIER2
AIRTREATMENT3 ZONING8 THERMOSTAT4
OPTION PACKAGES
MISCELLANEOUSOPTIONS LINE SET6
SEER1
W/TXVSEER W/
TXV & TDR HSPF
CAPACITY
EFFICIENCYENHANCEMENT
LONG LINE5
APPLICATION LOW AMBIENT ENERGY MINDERHTG
mBtuhCLG
mBtuh
Bypass49BF-018---1
( 18 GPD)49BG-013---2
( 17 GPD)
Fan Power49FH-024---1
( 25 GPD)49FP-017---1
( 18 GPD)
Water Saver49WS-020---1
( 19 GPD)
2nd OutdoorThermostat
KHAOT0201SEC
Interface ControlKHAIC0101AAA KHAIC0201AAA
Outdoor ThermostatKHAOT0301FST
![Page 102: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/102.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCEFURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
OPTIONSAFUE(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)InputBtuh
OutputBtuh
MULTIPOISE — 58BMA — 4-POSITION OIL-FIRED FURNACE
80.0 70,000 55,000 58BMA075---1--12 46 20 30
1
⁄
2
18 17 18
1
⁄
8
17
1
⁄
16
15 25
1
⁄
4
1290
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for
Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Downflow Subbase
(For 075 and 105 sizes only)KLASB0401DUC
(For 125 and 155 sizes only)KLASB0501DUC
Downflow Vent Pipe Guard
KLAVG0101DFG
Rear Return-Air Plenum
(For 195 size only)KLARP0101DUC
(For 260 size only)KLARP0201DUC
80.0 105,000 85,000 58BMA105---1--12 46 20 30
1
⁄
2
18 17 18
1
⁄
8
17
1
⁄
16
15 25
1
⁄
4
1455
80.0 125,000 100,000 58BMA125---1--16 48 22 35
1
⁄
2
20 22 20
1
⁄
8
22
1
⁄
16
15 30
1
⁄
4
1745
80.0 155,000 125,000 58BMA155---1--20 48 22 35
1
⁄
2
20 22 20
1
⁄
8
22
1
⁄
16
15 30
1
⁄
4
1935
UPFLOW — 58BLA — LOWBOY OIL-FIRED FURNACE
80.0 67,000 55,000 58BLA075---1--12 31 20 52 17
1
⁄
4
18 18 18 N/A 1300
80.7 105,000 85,000 58BLA105---1--12 31 20 52 17
1
⁄
4
18 18 18 N/A 1300
81.5 120,000 100,000 58BLA125---1--16 33 22 57 22
1
⁄
4
20 18 20 N/A 1630
80.0 154,000 125,000 58BLA155---1--20 33 22 57 22
1
⁄
4
20 18 20 N/A 1800
UPFLOW/HORIZONTAL — 58BTA — OIL-FIRED FURNACE
80.0 184,000 150,000 58BTA195---1--20 54
3
⁄
4
26 42
1
⁄
2
24 29 29
1
⁄
16
29 37
1
⁄
4
17
3
⁄
4
2145
80.0 260,000 200,000 58BTA260---1--20 54
3
⁄
4
26 42
1
⁄
2
24 29 29
1
⁄
16
29 37
1
⁄
4
17
3
⁄
4
2145
PRICE::
$ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × × ×
× × × × ×
Copyright 1996 Carrier Corporation
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
![Page 103: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/103.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
UPFLOWOPTIONS
DOWNFLOWOPTIONSAFUE
(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side ReturnOpening
H D (In.)InputBtuh
OutputBtuh
UPFLOW — 58GFA— INDUCED DRAFT, CONTINUOUS PILOT, SILVER SAGE
78.0 63,000 51,000 58GFA065---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
950
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP1801STP(Nat-to-Prop)
KGAPN1301STP(Prop-to-Nat)
Return-Air Plenum
KGARP0101ALL
Side Filter Rack
KGAFR0106ALL
Twinning Kit
KGATW0501STP
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
N/A
78.0 63,000 51,000 58GFA065---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1300 N/A
78.0 84,000 67,000 58GFA086---1--14 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1335 N/A
78.0 84,000 68,000 58GFA086---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1655 N/A
78.0 105,000 85,000 58GFA105---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1210 N/A
78.0 105,000 85,000 58GFA105---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1575 N/A
78.0 105,000 84,000 58GFA105---1--22 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2210 N/A
78.0 126,000 101,000 58GFA130---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1545 N/A
78.0 126,000 101,000 58GFA130---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1980 N/A
78.0 147,000 119,000 58GFA150---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1935 N/A
DOWNFLOW — 58DFA— INDUCED DRAFT, CONTINUOUS PILOT, SILVER SAGE
78.0 66,000 54,000 58DFA071---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 830 N/A
Gas Conv Kits
KGANP1801STP(Nat-to-Prop)
KGAPN1301STP(Prop-to-Nat)
Downflow Subbase
KGASB0101ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
78.0 66,000 54,000 58DFA071---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1300 N/A
78.0 88,000 71,000 58DFA091---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1395 N/A
78.0 88,000 71,000 58DFA091---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1580 N/A
78.0 110,000 89,000 58DFA110---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1595 N/A
78.0 110,000 89,000 58DFA110---1--20 39
7
⁄
8
21 28
1
⁄
2
19
1
⁄
2
19 19
3
⁄
8
20 N/A 1950 N/A
78.0 132,000 106,000 58DFA135---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
23 19 22
7
⁄
8
20 N/A 2070 N/A
PRICE::
$ $ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.Copyright 1996 Carrier Corporation
![Page 104: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/104.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCEFURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
OPTIONSAFUE(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)InputBtuh
OutputBtuh
MULTIPOISE — 58MCA — 4-WAY CONDENSING FURNACE
90.5 40,000 37,200 58MCA040---1--08 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
895
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Twinning Kit
KGATW0401HSI
Vent Termination Kit
(Required)
Bracket Only
2
″
—KGAVT0101BRA3
″
—KGAVT0201BRA
Concentric
2
″
—KGAVT0501CVT3
″
—KGAVT0601CVT
Cosmetic VentTermination Cover
2
″
—KGAVT0301COV3
″
—KGAVT0401COV
Gas Conv Kits
KGANP2001ALL(Nat-to-Prop)
KGAPN1601ALL(Prop-to-Nat)
Side Filter Rack
KGAFR0206ALL
Manufactured (Mobile) Home Kit
KGAMH0101KIT
Condensate Freeze Protection Kit
KGAHT0101CFP
Return-Air Plenum
KGARP0201ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
DownflowSubbase
KGASB0201ALL
90.5 40,000 37,200 58MCA040---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1230
90.5 60,000 55,800 58MCA060---1--08 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
900
90.5 60,000 55,800 58MCA060---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1250
90.5 60,000 55,800 58MCA060---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1545
90.5 80,000 74,400 58MCA080---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1255
90.5 80,000 74,400 58MCA080---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1525
90.5 80,000 74,400 58MCA080---1--20 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1925/2035
90.5 100,000 93,000 58MCA100---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1570
90.5 100,000 93,000 58MCA100---1--20 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1930/2130
90.5 120,000 111,600 58MCA120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
2000/2130
PRICE::
$ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
Copyright 1996 Carrier Corporation
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
![Page 105: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/105.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCEFURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
OPTIONSAFUE(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)Input*Btuh
Output*Btuh
4-WAY MULTIPOISE — 58MVP — WEATHERMAKER INFINITY VARIABLE-SPEED CONDENSING FURNACE
96.6 26,000/40,000
25,000/38,000 58MVP040---1--14 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1400
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Vent Termination Kit
(Required)
Bracket Only
2
″
—KGAVT0101BRA3
″
—KGAVT0201BRA
Concentric
2
″
—KGAVT0501CVT3
″
—KGAVT0601CVT
Cosmetic VentTermination Cover
2
″
—KGAVT0301COV3
″
—KGAVT0401COV
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Side Filter Rack
(Upflow only)KGAFR0206ALL
Return-AirPlenum
(Upflow only)KGARP0201ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
Condensate Freeze
Protection Kit
KGAHT0101CFP
DownflowSubbase
KGASB0201ALL
94.0 39,000/60,000
37,000/56,000 58MVP060---1--14 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1400
94.0 52,000/80,000
49,000/74,000 58MVP080---1--14 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
1400
94.0 52,000/80,000
49,000/74,000 58MVP080---1--20 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
2000
94.0 65,000/100,000
61,000/93,000 58MVP100---1--20 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
2000
94.0 78,000/120,000
73,000/111,000 58MVP120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 23
1
⁄
4
14
1
⁄
2
23
1
⁄
4
2000
PRICE::
$ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
Copyright 1996 Carrier Corporation
*Low fire/high fire
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
![Page 106: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/106.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
UPFLOWOPTIONS
DOWNFLOWOPTIONSAFUE
(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side ReturnOpening
H D (In.)InputBtuh
OutputBtuh
UPFLOW — 58PAV — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 44,000 35,000 58PAV045---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
930
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP2001ALL(Nat-to-Prop)
KGAPN1601ALL(Prop-to-Nat)
Return-Air Plenum
KGARP0101ALL
Side Filter Rack
KGAFR0101ALL
Twinning Kit
KGATW0301HSI
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
N/A
80.0 44,000 35,000 58PAV045---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1270 N/A
80.0 66,000 53,000 58PAV070---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
950 N/A
80.0 66,000 53,000 58PAV070---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1300 N/A
80.0 88,000 71,000 58PAV090---1--14 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1335 N/A
80.0 88,000 71,000 58PAV090---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1740 N/A
80.0 110,000 89,000 58PAV111---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1210 N/A
80.0 110,000 89,000 58PAV111---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1575 N/A
80.0 110,000 89,000 58PAV111---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2210 N/A
80.0 132,000 107,000 58PAV135---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1620 N/A
80.0 132,000 107,000 58PAV135---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1980 N/A
80.0 154,000 124,000 58PAV155---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1905 N/A
DOWNFLOW — 58RAV — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 46,000 37,000 58RAV050---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 895 N/A
Gas Conv Kits
KGANP2001ALL(Nat-to-Prop)
KGAPN1601ALL(Prop-to-Nat)
Downflow Subbase
KGASB0101ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
80.0 46,000 37,000 58RAV050---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1215 N/A
80.0 69,000 56,000 58RAV070---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 930 N/A
80.0 69,000 56,000 58RAV070---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1300 N/A
80.0 92,000 75,000 58RAV095---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1395 N/A
80.0 92,000 75,000 58RAV095---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1580 N/A
80.0 115,000 94,000 58RAV115---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1595 N/A
80.0 115,000 94,000 58RAV115---1--20 39
7
⁄
8
21 28
1
⁄
2
19
1
⁄
2
19 19
3
⁄
8
20 N/A 1950 N/A
80.0 135,000 110,000 58RAV135---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
23 19 22
7
⁄
8
20 N/A 2055 N/A
PRICE:
$ $ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
1. Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2. Thermostat not needed if Comfort Zone kit is purchased.3. Size dependent on home duct size.
Copyright 1996 Carrier Corporation
![Page 107: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/107.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
UPFLOWOPTIONS
DOWNFLOWOPTIONSAFUE
(%)
CapacityOverall
H W D(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)
InputBtuh
OutputBtuh
High/Low High/Low
UPFLOW — WEATHERMAKER 8000 TWO SPEED (58TUA) — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 40,000/26,000
32,000/ 21,000 58TUA040---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 12
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1270
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Return-Air Plenum
KGARP0201ALL
Side Filter Rack
KGAFR0201ALL
Twinning Kit
KGATW0301HSI
Interface Kit—Var Spd
38TV-900-001
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
Hi-Alt Kit
KGAHA5501PSW
Cat III Vent Conv Kits
KGASW01012SPKGASW02012SP
N/A
80.0 60,000/39,000
49,000/ 31,000 58TUA060---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 12
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
880 N/A
80.0 60,000/ 39,000
49,000/ 31,000 58TUA060---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 12
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1300 N/A
80.0 80,000/ 52,000
65,000/ 42,000 58TUA080---1--14 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1335 N/A
80.0 80,000/ 52,000
65,000/ 42,000 58TUA080---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1740 N/A
80.0 100,000/ 65,000
81,000/ 52,000 58TUA100---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1210 N/A
80.0 100,000/ 65,000
81,000/ 52,000 58TUA100---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1575 N/A
80.0 100,000/ 65,000
81,000/ 52,000 58TUA100---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2210 N/A
80.0 120,000/ 78,000
98,000/ 63,000 58TUA120---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1620 N/A
80.0 120,000/ 78,000
98,000/ 63,000 58TUA120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1980 N/A
80.0 133,000/ 91,000
108,000/ 73,000 58TUA135---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1905 N/A
MULTIPOISE — WEATHERMAKER 8000 TWO SPEED (58TMA) — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 63,000/ 40,500
51,000/ 33,000 58TMA065---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 930 N/A
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Downflow Subbase
KGASB0101ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56
Cat III Vent Conv Kits
KGASW01012SPKGASW02012SP
80.0 63,000/ 40,500
51,000/ 33,000 58TMA065---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1300 N/A
80.0 84,000/ 54,000
68,000/ 44,000 58TMA085---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1395 N/A
80.0 84,000/ 54,000
68,000/ 44,000 58TMA085---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1580 N/A
80.0 105,000/ 67,500
85,000/ 55,000 58TMA105---1--20 39
7
⁄
8
21 28
1
⁄
2
19
1
⁄
2
19 19
3
⁄
8
20 N/A 1950 N/A
80.0 123,000/ 81,000
99,000/ 65,000 58TMA125---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
23 19 22
7
⁄
8
20 N/A 2055 N/A
N/A
PRICE:
$ $ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
Copyright 1996 Carrier Corporation
![Page 108: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/108.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
OPTIONSAFUE(%)
CapacityOverall
H W D(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)
InputBtuh
OutputBtuh
High/Low High/Low
UPFLOW/HORIZONTAL — WEATHERMAKER 8000 VARIABLE-SPEED (58UHV) — INDUCED COMBUSTION, HOT SURFACE IGNITION
80.0 60,000/ 39,000
49,000/ 31,000 58UHV060---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 12
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1250
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Return-Air Plenum
KGARP0201ALL
Side Filter Rack
KGAFR0201ALL
Twinning Kit
KGATW0301HSI
Interface Kit—Var Spd
38TV-900-001
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
Hi-Alt Kit
KGAHA5501PSW
Cat III Vent Conv Kits
KGASW01012SPKGASW02012SP
80.0 80,000/ 52,000
65,000/ 42,000 58UHV080---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1635
80.0 100,000/ 65,000
82,000/ 53,000 58UHV100---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2085
80.0 117,000/ 78,000
96,000/ 63,000 58UHV120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2110
PRICE:
$ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
Copyright 1996 Carrier Corporation
![Page 109: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/109.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONSMAXIMUM AIRFLOW
(CFM @ 0.5 IN. WC)
AIR TREATMENT
1
ZONING THERMOSTAT
2
UPFLOWOPTIONS
DOWNFLOWOPTIONSAFUE
(%)
CapacityOverall
H W D(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side Return Opening
H D (In.)
InputBtuh
OutputBtuh
High/Low High/Low
UPFLOW/HORIZONTAL — WEATHERMAKER 8000 TWO SPEED (58UXT) — INDUCED COMBUSTION, HOT SURFACE IGNITION
80.0 60,000/ 39,000
48,000/ 31,000 58UXT060---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 12
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1300
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Return-Air Plenum
KGARP0201ALL
Side Filter Rack
KGAFR0201ALL
Twinning Kit
KGATW0301HSI
Interface Kit—Var Spd
38TV-900-001
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
Hi-Alt Kit
KGAHA5501PSW
Cat III Vent Conv Kits
KGASW01012SPKGASW02012SP
N/A
80.0 80,000/ 52,000
64,000/ 42,000 58UXT080---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1740
80.0 100,000/ 65,000
81,000/ 52,000 58UXT100---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 19
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1575
80.0 100,000/ 65,000
81,000/ 52,000 58UXT100---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2210
80.0 117,000/ 78,000
94,000/ 63,000 58UXT120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 23 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1980
DOWNFLOW — WEATHERMAKER 8000 TWO SPEED (58DXT) — INDUCED COMBUSTION, HOT SURFACE IGNITION
80.0 63,000/ 40,500
51,000/ 33,000 58DXT060---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1300
N/A
Gas Conv Kits
KGANP24012SP(Nat-to-Prop)
KGAPN20012SP(Prop-to-Nat)
Downflow Subbase
KGASB0101ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56
Cat III Vent Conv Kits
KGASW01012SPKGASW02012SP
Hi-Alt Kit
KGAHA5601PSW
80.0 84,000/ 54,000
69,000/ 44,000 58DXT080---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1580
80.0 105,000/ 67,500
85,000/ 55,000 58DXT100---1--20 39
7
⁄
8
21 28
1
⁄
2
19
1
⁄
2
19 19
3
⁄
8
20 N/A 1950
80.0 123,000/ 81,000
99,000/ 65,000 58DXT120---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
23 19 22
7
⁄
8
20 N/A 2055
PRICE:
$ $ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
1.
Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2.
Thermostat not needed if Comfort Zone kit is purchased.
3.
Size dependent on home duct size.
Copyright 1996 Carrier Corporation
![Page 110: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/110.jpg)
FURNACE/ACCESSORY REFERENCE GUIDE
PERFORMANCE
FURNACECATALOGNUMBER
DIMENSIONS
MAXIMUM AIRFLOW
CFM @ 0.5AIR TREATMENT
1
ZONING THERMOSTAT
2
UPFLOWOPTIONS
DOWNFLOWOPTIONSAFUE
(%)
Capacity OverallH W D
(In.)
Supply Opening
W D (In.)
Return Opening
W D (In.)
Side ReturnOpening
H D (In.)InputBtuh
OutputBtuh
UPFLOW — WEATHERMAKER 8000 (58WAV) — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 44,000 35,000 58WAV045---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
880
Duct Mounted EAC
31KAX012(300 to 1400 CFM)
31KAX016(500 to 1800 CFM)
31KAX020(700 to 2000 CFM)
Mechanical EAC
31MF020(600 to 2000 CFM)
Grille Mounted EAC
31RX-010(500 to 1000 CFM)
31RX-016(800 to 1600 CFM)
31RX-020(900 to 2000 CFM)
Bypass Humidifier
49BF (18 GPD)49BG (17 GPD)
Energy Recovery Ventilator
VL3AAA015000VL3AAA020000
Comfort Ventilator
VA3BAB015000VA3BAB020000VB5BAB015000VB5BAB020000VC5BAB015000VC5BAB020000VC5BAB027000
Fan Powered Humidifier
49FH (25 GPD)49FP (18 GPD)
Water Saver Humidifier
49WS (19 GPD)
45 Degree Damper Actuator
DAMPACT45DEG
90 Degree Damper Actuator
DAMPACT90DEG
Barometric Bypass
DAMPBAR08X14DAMPBAR08X24
Rectangular Dampers
3
DAMPREC08X10DAMPREC08X14DAMPREC08X18DAMPREC08X24DAMPREC10X10DAMPREC10X14DAMPREC10X18DAMPREC10X24
Round Dampers
3
DAMPRND06INCDAMPRND08INCDAMPRND10INCDAMPRND12INCDAMPRND14INCDAMPRND16INC
Slip-In Dampers (Bottom Mount)
DAMPSLB08X10DAMPSLB08X12DAMPSLB08X14DAMPSLB08X16DAMPSLB08X18DAMPSLB08X20DAMPSLB08X22DAMPSLB08X24DAMPSLB10X10DAMPSLB10X12DAMPSLB10X14DAMPSLB10X16DAMPSLB10X18DAMPSLB10X20DAMPSLB10X22DAMPSLB10X24DAMPSLB14X20
Slip-In Dampers (Side Mount)
DAMPSLS08X10DAMPSLS08X12DAMPSLS08X14DAMPSLS08X16DAMPSLS08X18DAMPSLS10X10DAMPSLS10X12DAMPSLS10X14DAMPSLS10X16DAMPSLS10X18
Carrier Weathermaker Two Zone
ZONEKIT2ZCAR
Comfort Zone
ZONEKIT4ZCAR
Smart Sensor
ZONESMSENCAR
Smart Sensor Power Pack
ZONESMSENPPC
Smart Sensor Connector Board
ZONESMSENCBD
Command Center
ZONECZCCCARR
Four Zone Controller
ZONE4ZCONTCA
Four Zone Controller Cover
ZONE4ZCONCOV
Duct Temperature Sensor
(2-Zone Only)
ZONEDUCTTSEN
Home Access Module
ZONEHAMCAR4Z
Comfort Zone Input/Output Center
ZONEIOCENTCA
Comfort Zone Input/Output Board
ZONEIOBDCARR
Fuse Pack for Zoning Products
ZONEFUSEPACK
Multi-Damper Enabler
ZONEMLTDMPEN
Auto Changeover7-Day
Programmable
TSTATCCPAC01-ATSTATCCPHP01-ATSTATCCP2S01-ATSTATCCPDF01-A
Auto ChangeoverNon-Programmable
TSTATCCNAC01-ATSTATCCNHP01-ATSTATCCN2S01-A
Outdoor Sensor
TSTATCCSEN01
Backplate for Programmable
TSTATXXPBP01
Backplate for Non-Programmable
TSTATXXNBP01
Manual Changeover
--HH--07AT-213--HH--07AT-215
Gas Conv Kits
KGANP2001ALL(Nat-to-Prop)
KGAPN1601ALL(Prop-to-Nat)
Return-AirPlenum
KGARP0101ALL
Side Filter Rack
KGAFR0101ALL
Twinning Kit
KGATW0301HSI
Motor Kit Var Spd
KGAMK0101VSP
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
N/A
80.0 44,000 35,000 58WAV045---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1270 N/A
80.0 66,000 53,000 58WAV070---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
880 N/A
80.0 66,000 53,000 58WAV070---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
9
⁄
16
19 11
11
⁄
16
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1300 N/A
80.0 88,000 71,000 58WAV091---1--14 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1335 N/A
80.0 88,000 71,000 58WAV091---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1740 N/A
80.0 110,000 89,000 58WAV111---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
15
7
⁄
8
19 16 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1210 N/A
80.0 110,000 89,000 58WAV111---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1575 N/A
80.0 110,000 89,000 58WAV111---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
2210 N/A
80.0 132,000 107,000 58WAV136---1--16 39
7
⁄
8
21 28
1
⁄
2
19
3
⁄
8
19 18
1
⁄
2
24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1620 N/A
80.0 132,000 107,000 58WAV136---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1980 N/A
80.0 154,000 124,000 58WAV155---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
22
7
⁄
8
19 22 24
5
⁄
16
14
1
⁄
2
23
1
⁄
4
1905 N/A
MULTIPOISE — WEATHERMAKER 8000 (58ZAV) — INDUCED DRAFT, HOT SURFACE IGNITION
80.0 46,000 37,000 58ZAV050---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 895 N/A
Gas Conv Kits
KGANP2001ALL(Nat-to-Prop)
KGAPN1601ALL(Prop-to-Nat)
DownflowSubbase
KGASB0101ALL
Orifices
KGAHA0150N42KGAHA0250N43KGAHA0350N44KGAHA0450N45KGAHA0550N46KGAHA0650P54KGAHA0750P55KGAHA0850P56KGAHA1550N47KGAHA1650N48KGAHA5750125
80.0 46,000 37,000 58ZAV050---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1215 N/A
80.0 69,000 56,000 58ZAV070---1--08 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 930 N/A
80.0 69,000 56,000 58ZAV070---1--12 39
7
⁄
8
14
3
⁄
16
28
1
⁄
2
12
11
⁄
16
19 12
9
⁄
16
20 N/A 1300 N/A
80.0 92,000 75,000 58ZAV096---1--12 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1395 N/A
80.0 92,000 75,000 58ZAV096---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1580 N/A
80.0 115,000 94,000 58ZAV115---1--16 39
7
⁄
8
17
1
⁄
2
28
1
⁄
2
16 19 15
7
⁄
8
20 N/A 1595 N/A
80.0 115,000 94,000 58ZAV115---1--20 39
7
⁄
8
21 28
1
⁄
2
19
1
⁄
2
19 19
3
⁄
8
20 N/A 1950 N/A
80.0 135,000 110,000 58ZAV135---1--20 39
7
⁄
8
24
1
⁄
2
28
1
⁄
2
23 19 22
7
⁄
8
20 N/A 2055 N/A
PRICE::
$ $ $ $ $ $
NOTES TOTAL SYSTEM
$
× ×× × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
× × × ×
1. Air cleaner size based on system airflow. Humidifier size based on relative humidity needs.
2. Thermostat not needed if Comfort Zone kit is purchased.3. Size dependent on home duct size.
Copyright 1996 Carrier Corporation
![Page 111: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/111.jpg)
FURNACE/COIL REFERENCE GUIDE
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD5A INDOOR COIL
NOMINAL COOLING SIZE
018 024 030 030W 036 036W 042 042W 043 043W 048 048W 048C 060 060W
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 17-1/2 21 21 24-1/2 21 24-1/2 21 24-1/2 21 24-1/2 31-1/2
58GFA
065-08 14-3/16 24 X X
065-12 14-3/16 36 X X X O O
086-14 17-1/2 36 X X O
086-16 21 48 X X O X O X O X
105-12 17-1/2 36 X X O
105-16 21 48 X X O X O X O X
105-22 24-1/2 60 X X X X O
130-16 21 48 X X O X O X O X
130-20 24-1/2 60 X X X X O
150-20 24-1/2 60 X X X X O
58DFA
071-08 14-3/16 24 X X
071-12 14-3/16 36 X X X O O
091-12 17-1/2 36 X X O
091-16 17-1/2 48 X X O O O O O
110-16 17-1/2 48 X X O O O O O
110-20 21 60 X X O X O X O X O
135-20 24-1/2 60 X X X X O
X = COIL AND FURNACE ARE FLUSH.O = COIL OVERHANGS FURNACE. TRANSITION REQUIRED FOR DOWNFLOW.
![Page 112: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/112.jpg)
FURNACE/COIL REFERENCE GUIDE
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD5A INDOOR COIL
NOMINAL COOLING SIZE
018 024 030 030W 036 036W 042 042W 043 043W 048 048W 048C 060 060W
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 17-1/2 21 21 24-1/2 21 24-1/2 21 24-1/2 21 24-1/2 31-1/2
58PAV
045-08 14-3/16 24 X X
045-12 14-3/16 36 X X X O O
070-08 14-3/16 24 X X
070-12 14-3/16 36 X X X O O
090-14 17-1/2 36 X X O
090-16 21 48 X X O X O X O X
111-12 17-1/2 36 X X O
111-16 21 48 X X O X O X O X
111-20 24-1/2 60 X X X X O
135-16 21 48 X X O X O X O X
135-20 24-1/2 60 X X X X O
155-20 24-1/2 60 X X X X O
58RAV
050-08 14-3/16 24 X X
050-12 14-3/16 36 X X X O O
070-08 14-3/16 24 X X
070-12 14-3/16 36 X X X O O
095-12 17-1/2 36 X X O
095-16 17-1/2 48 X X O O O O O
115-16 17-1/2 48 X X O O O O O
115-20 21 60 X X O X O X O X O
135-20 24-1/2 60 X X X X O
X = COIL AND FURNACE ARE FLUSH.O = COIL OVERHANGS FURNACE. TRANSITION REQUIRED FOR DOWNFLOW.
![Page 113: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/113.jpg)
FURNACE/COIL REFERENCE GUIDE
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD5A INDOOR COIL-UPFLOW/DOWNFLOW
NOMINAL COOLING SIZE
018 024 030 030W 036 036W 042 042W 043 043W 048 048W 048C 060 060W
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 17-1/2 21 21 24-1/2 21 24-1/2 21 24-1/2 21 24-1/2 31-1/2
58MVP
040-14 24-1/2 42 X X X X O
060-14 17-1/2 42 X X O O O
080-14 21 42 X X O X O X
100-20 21 60 X X O X O X O X O
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD3A INDOOR COIL-HORIZONTAL
NOMINAL COOLING SIZE
018 024 030 036 042 048 060
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 21 21 24-1/2
58MVP
040-14 24-1/2 42 T T
060-14 17-1/2 42 X T T
080-14 21 42 T T X
100-20 21 60 X T
X = COIL AND FURNACE ARE FLUSH.O = COIL OVERHANGS FURNACE FOR UPLFLOW. TRANSITION REQUIRED FOR DOWNFLOW.T = TRANSITION REQUIRED FOR HORIZONTAL.
![Page 114: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/114.jpg)
FURNACE/COIL REFERENCE GUIDE
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD5A INDOOR COIL-UPFLOW/DOWNFLOW
NOMINAL COOLING SIZE
018 024 030 030W 036 036W 042 042W 043 043W 048 048W 048C 060 060W
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 17-1/2 21 21 24-1/2 21 24-1/2 21 24-1/2 21 24-1/2 31-1/2
58MXA/58MCA
040-08 17-1/2 24 X X X O O
040-12 17-1/2 36 X O O
060-12 17-1/2 36 X O O
060-16 17-1/2 48 X X O O O O O
080-12 17-1/2 36 X X O O O O O
080-16 17-1/2 48 X X O O O O O
080-20 21 60 X X O X O X O X O
100-16 21 48 X X O X O X O X O
100-20 21 60 X X O X O X O X O
120-20 24-1/2 60 O O O X X X X O
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
CD3A INDOOR COIL-HORIZONTAL
NOMINAL COOLING SIZE
018 024 030 036 042 048 060
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 21 21 24-1/2
58MXA/58MCA
040-08 17-1/2 24 T X
040-12 17-1/2 36 X T
060-12 17-1/2 36 X T
060-16 17-1/2 48 T T T
080-12 17-1/2 36 X T
080-16 17-1/2 48 X T T
080-20 21 60 X T
100-16 21 48 X X T
100-20 21 60 X T
120-20 24-1/2 60 T X
X = COIL AND FURNACE ARE FLUSH.O = COIL OVERHANGS FURNACE FOR UPFLOW. TRANSITION REQUIRED FOR DOWNFLOW.T = TRANSITION REQUIRED FOR HORIZONTAL.
![Page 115: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/115.jpg)
FURNACE/COIL REFERENCE GUIDE
FURNACEMODEL
NO.
FURNACEWIDTH
(IN.)
NOMINALCOOLING
SIZE
HORIZONTAL CE3AXA INDOOR COIL
NOMINAL COOLING SIZE
018 024 030 036 042 048 060
CASING WIDTH (IN.)
14-3/16 14-3/16 14-3/16 17-1/2 21 21 24-1/2
58RAV
050-08 14-3/16 24 X X
050-12 14-3/16 36 X X X O
070-08 14-3/16 24 X X
070-12 14-3/16 36 X X X O
095-12 17-1/2 36 X
095-16 17-1/2 48 X O O
115-16 17-1/2 48 X O O
115-20 21 60 X X O
135-20 24-1/2 60 X
X = COIL AND FURNACE ARE FLUSH.O = COIL IS LARGER THAN FURNACE.
BLANK OFF SPACE WITH SHEET METAL (NO TRANSITION REQUIRED).
![Page 116: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/116.jpg)
BOILER/ACCESSORY REFERENCE GUIDE
CATALOGNUMBER
FUELTYPE
BOILERTYPE AFUE INPUT
BTUHOUTPUT
BTUHI = B = ROUTPUT
OVERALLH W D (In.)
# OFSECT
ACCESSORIES
SPECIALINSTALLATIONS ZONING SYSTEM
ENHANCEMENT SAFETY
STANDING PILOT STEAM BOILERS
BS1AAN000112 NATURAL GAS STEAM 78.8 112,500 91,000 68,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
CombustibleFloor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
None None None
BS1AAN000150 NATURAL GAS STEAM 79.2 150,000 122,000 92,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BS1AAN000187 NATURAL GAS STEAM 79.6 187,500 153,000 115,000 31
3
⁄
8
21 26
1
⁄
2
6
BS1AAN000225 NATURAL GAS STEAM 80.1 225,000 183,000 137,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BS1AAN000262 NATURAL GAS STEAM 80.5 262,500 214,000 161,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BS1AAN000299 NATURAL GAS STEAM 80.9 299,000 245,000 184,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
BS1AAP000105 PROPANE STEAM 78.8 105,000 85,000 64,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BS1AAP000140 PROPANE STEAM 79.2 140,000 114,000 86,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BS1AAP000175 PROPANE STEAM 79.6 175,000 143,000 107,000 31
3
⁄
8
21 26
1
⁄
2
6
BS1AAP000210 PROPANE STEAM 80.1 210,000 171,000 128,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BS1AAP000245 PROPANE STEAM 80.5 245,000 200,000 150,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BS1AAP000280 PROPANE STEAM 80.9 280,000 229,000 172,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
INTERMITTENT IGNITION (IID) STEAM BOILERS
BS2AAN000112 NATURAL GAS STEAM 80.4 112,500 91,000 68,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
CombustibleFloor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
None None None
BS2AAN000150 NATURAL GAS STEAM 80.6 150,000 122,000 92,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BS2AAN000187 NATURAL GAS STEAM 80.9 187,500 153,000 115,000 31
3
⁄
8
21 26
1
⁄
2
6
BS2AAN000225 NATURAL GAS STEAM 81.1 225,000 183,000 137,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BS2AAN000262 NATURAL GAS STEAM 81.3 262,500 214,000 161,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BS2AAN000299 NATURAL GAS STEAM 81.5 299,000 245,000 184,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
BS2AAP000105 PROPANE STEAM 80.4 105,000 85,000 64,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BS2AAP000140 PROPANE STEAM 80.6 140,000 114,000 86,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BS2AAP000175 PROPANE STEAM 80.9 175,000 143,000 107,000 31
3
⁄
8
21 26
1
⁄
2
6
BS2AAP000210 PROPANE STEAM 81.1 210,000 171,000 128,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BS2AAP000245 PROPANE STEAM 81.3 245,000 200,000 150,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BS2AAP000280 PROPANE STEAM 81.5 280,000 229,000 172,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
![Page 117: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/117.jpg)
BOILER/ACCESSORY REFERENCE GUIDE
CATALOGNUMBER
FUELTYPE
BOILERTYPE AFUE INPUT
BTUHOUTPUT
BTUHI = B = ROUTPUT
OVERALLH W D (In.)
# OFSECT
ACCESSORIES
SPECIALINSTALLATIONS ZONING SYSTEM
ENHANCEMENT SAFETY
STANDING PILOT HOT WATER BOILERS
BW1AAN000037 NATURAL GAS WATER 80.0 37,500 30,000 26,000 31
3
⁄
8
8 26
1
⁄
2
2
CombustibleFloor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
Gas ConversionKit
(Prop-to-Nat)KBAPN0101DNK
Zoning Valves
3
⁄
4
″
KBAZV0101DNK
1
″
KBAZV0201DNK
Filltrol Package(Includes air
purge tank andfill valve)
2-3 SectionKBAFP0101DNK
4-5 SectionKBAFP0201DNK
6-9 SectionKBAFP0301DNK
High LimitControl
KBAHL0101DNK
BW1AAN000070 NATURAL GAS WATER 80.4 70,000 57,000 50,000 31
3
⁄
8
11
1
⁄
4
26
1
⁄
2
3
BW1AAN000105 NATURAL GAS WATER 80.4 105,000 85,000 74,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BW1AAN000140 NATURAL GAS WATER 80.3 140,000 113,000 98,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BW1AAN000175 NATURAL GAS WATER 80.2 175,000 142,000 124,000 31
3
⁄
8
21 26
1
⁄
2
6
BW1AAN000210 NATURAL GAS WATER 80.1 210,000 170,000 148,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BW1AAN000245 NATURAL GAS WATER 80.0 245,000 198,000 172,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BW1AAN000280 NATURAL GAS WATER 80.0 280,000 226,000 197,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
BW1AAP000070 PROPANE WATER 80.4 70,000 57,000 50,000 31
3
⁄
8
11
1
⁄
4
26
1
⁄
2
3
BW1AAP000105 PROPANE WATER 80.4 105,000 85,000 74,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BW1AAP000140 PROPANE WATER 80.3 140,000 113,000 98,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BW1AAP000175 PROPANE WATER 80.2 175,000 142,000 124,000 31
3
⁄
8
21 26
1
⁄
2
6
BW1AAP000210 PROPANE WATER 80.1 210,000 170,000 148,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BW1AAP000245 PROPANE WATER 80.0 245,000 198,000 172,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BW1AAP000280 PROPANE WATER 80.0 280,000 226,000 197,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
INTERMITTENT IGNITION (IID) HOT WATER BOILERS
BW2AAN000037 NATURAL GAS WATER 81.4 37,500 30,000 26,000 31
3
⁄
8
8 26
1
⁄
2
2
CombustibleFloor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
Gas ConversionKit
(Prop-to-Nat)KBAPN0101DNK
Zoning Valves
3
⁄
4
″
KBAZV0101DNK
1
″
KBAZV0201DNK
Filltrol Package(Includes air
purge tank andfill valve)
2-3 SectionKBAFP0101DNK
4-5 SectionKBAFP0201DNK
6-9 SectionKBAFP0301DNK
High LimitControl
KBAHL0101DNK
BW2AAN000070 NATURAL GAS WATER 81.6 70,000 57,000 50,000 31
3
⁄
8
11
1
⁄
4
26
1
⁄
2
3
BW2AAN000105 NATURAL GAS WATER 81.5 105,000 85,000 74,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BW2AAN000140 NATURAL GAS WATER 81.3 140,000 113,000 98,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BW2AAN000175 NATURAL GAS WATER 81.1 175,000 142,000 124,000 31
3
⁄
8
21 26
1
⁄
2
6
BW2AAN000210 NATURAL GAS WATER 81.0 210,000 170,000 148,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BW2AAN000245 NATURAL GAS WATER 81.6 245,000 198,000 172,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BW2AAN000280 NATURAL GAS WATER 80.7 280,000 226,000 197,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
BW2AAP000037 PROPANE WATER 81.4 37,500 30,000 26,000 31
3
⁄
8
8 26
1
⁄
2
2
BW2AAP000070 PROPANE WATER 81.6 70,000 57,000 50,000 31
3
⁄
8
11
1
⁄
4
26
1
⁄
2
3
BW2AAP000105 PROPANE WATER 81.5 105,000 85,000 74,000 31
3
⁄
8
14
1
⁄
2
26
1
⁄
2
4
BW2AAP000140 PROPANE WATER 81.3 140,000 113,000 98,000 31
3
⁄
8
17
3
⁄
4
26
1
⁄
2
5
BW2AAP000175 PROPANE WATER 81.1 175,000 142,000 124,000 31
3
⁄
8
21 26
1
⁄
2
6
BW2AAP000210 PROPANE WATER 81.0 210,000 170,000 148,000 31
3
⁄
8
24
1
⁄
4
26
1
⁄
2
7
BW2AAP000245 PROPANE WATER 80.8 245,000 198,000 172,000 31
3
⁄
8
27
1
⁄
2
26
1
⁄
2
8
BW2AAP000280 PROPANE WATER 80.7 280,000 226,000 197,000 31
3
⁄
8
30
3
⁄
4
26
1
⁄
2
9
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
![Page 118: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/118.jpg)
BOILER/ACCESSORY REFERENCE GUIDE
CATALOGNUMBER
FUELTYPE
BOILERTYPE AFUE INPUT
BTUHOUTPUT
BTUHI = B = ROUTPUT
OVERALLH W D (In.)
# OF SECT
ACCESSORIES
SPECIALINSTALLATIONS ZONING SYSTEM
ENHANCEMENT SAFETY
INDUCED-DRAFT WATER BOILERS
BW3AAN000042 NATURAL GAS WATER 84.4 42,500 36,000 31,000
29 11 23
1
⁄
4
2
CombustibleFloor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
Gas ConversionKit
(Prop-to-Nat)KBAPN0101DNK
Zoning Valve
3
⁄
4
″
KBAZV0101DNK
1
″
KBAZV0201DNK
Filltrol Package(Includes air
purge tank andfill valve)
2-3 SectionKBAFP0101DNK
4-5 SectionKBAFP0201DNK
6-9 SectionKBAFP0301DNK
High LimitControl
KBAHL0101DNK
BW3AAN000075 NATURAL GAS WATER 83.4 75,000 63,000 55,000 29 14
1
⁄
4
23
1
⁄
4
3
BW3AAN000112 NATURAL GAS WATER 83.0 112,500 94,000 82,000 29 17
1
⁄
2
23
1
⁄
4
4
BW3AAN000150 NATURAL GAS WATER 82.7 150,000 125,000 109,000 29 20
3
⁄
4
23
1
⁄
4
5
BW3AAN000187 NATURAL GAS WATER 82.3 187,500 155,000 135,000 29 24 23
1
⁄
4
6
BW3AAN000225 NATURAL GAS WATER 82.0 225,000 186,000 162,000 29 27
1
⁄
4
23
1
⁄
4
7
BW3AAP000042 PROPANE WATER 84.4 42,500 36,000 31,000 29 11 23
1
⁄
4
2
BW3AAP000075 PROPANE WATER 83.4 75,000 63,000 55,000 29 14
1
⁄
4
23
1
⁄
4
3
BW3AAP000112 PROPANE WATER 83.0 112,500 94,000 82,000 29
3
⁄
8
17
1
⁄
2
23
1
⁄
4
4
BW3AAP000150 PROPANE WATER 82.7 150,000 125,000 109,000 29 20
3
⁄
4
23
1
⁄
4
5
BW3AAP000187 PROPANE WATER 82.3 187,500 155,000 135,000 29 24 23
1
⁄
4
6
BW3AAP000225 PROPANE WATER 82.0 225,000 186,000 162,000 29 27
1
⁄
4
23
1
⁄
4
7
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
![Page 119: HOW TO USE THE SYSTEM REFERENCE GUIDE · HOW TO USE THE SYSTEM REFERENCE GUIDE The System Reference Guide was designed to be a simple to use, comprehensive resource which will aid](https://reader030.vdocuments.mx/reader030/viewer/2022033118/5e9b683020583d69fb792288/html5/thumbnails/119.jpg)
BOILER/ACCESSORY REFERENCE GUIDE
CATALOGNUMBER
FUELTYPE
BOILERTYPE AFUE INPUT
G.P.H.OUTPUT
BTUHI = B = ROUTPUT
OVERALLH W D (In.)
# OFSECT
ACCESSORIES
SPECIALINSTALLATIONS ZONING SYSTEM
ENHANCEMENT SAFETY
OIL FIRED WITH TANKLESS COIL WATER HEATER
BW5AAH000074 OIL WATER 86.1 0.60 74,000 64,000 36 19
5
⁄
8
17
3
⁄
4
3
Combustible Floor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
Tankless Water Heater Kit
KBATH0101DNK
Zoning Valves
3
⁄
4
″
KBAZV0101DNK
1
″
KBAZV0201DNK
Filltrol Package(Includes air purgetank and fill valve)
2-3 SectionKBAFP0101DNK
4-5 SectionKBAFP0201DNK
High LimitControl
KBAHL0101DNK
BW5AAH000092 OIL WATER 85.6 0.75 92,000 80,000 36 19
5
⁄
8
17
3
⁄
4
3
BW5AAH000120 OIL WATER 84.4 1.00 120,000 104,000 36 19
5
⁄
8
17
3
⁄
4
3
BW5AAH000111 OIL WATER 86.4 0.90 111,000 97,000 36 19
5
⁄
8
21 4
BW5AAH000153 OIL WATER 85.9 1.25 153,000 133,000 36 19
5
⁄
8
21 4
BW5AAH000181 OIL WATER 85.1 1.50 181,000 157,000 36 19
5
⁄
8
21 4
BW5AAH000147 OIL WATER 86.1 1.20 147,000 128,000 36 19
5
⁄
8
24
1
⁄
4
5
BW5AAH000210 OIL WATER 84.8 1.75 210,000 183,000 36 19
5
⁄
8
24
1
⁄
4
5
BW5AAH000239 OIL WATER 84.0 2.00 239,000 209,000 36 19
5
⁄
8
24
1
⁄
4
5
OIL FIRED WITHOUT TANKLESS COIL WATER HEATER
BW4AAH000074 OIL WATER 86.1 0.60 74,000 64,000 36 19
5
⁄
8
17
3
⁄
4
3
Combustible Floor Base
2-5 SectionKBASB0301DNK
6-9 SectionKBASB0401DNK
Tankless Water Heater Kit
KBATH0101DNK
Zoning Valves
3
⁄
4
″
KBAZV0101DNK
1
″
KBAZV0201DNK
Filltrol Package(Includes air purgetank and fill valve)
2-3 SectionKBAFP0101DNK
4-5 SectionKBAFP0201DNK
High LimitControl
KBAHL0101DNK
BW4AAH000092 OIL WATER 85.6 0.75 92,000 80,000 36 19
5
⁄
8
17
3
⁄
4
3
BW4AAH000120 OIL WATER 84.4 1.00 120,000 104,000 36 19
5
⁄
8
17
3
⁄
4
3
BW4AAH000111 OIL WATER 86.4 0.90 111,000 97,000 36 19
5
⁄
8
21 4
BW4AAH000153 OIL WATER 85.9 1.25 153,000 133,000 36 19
5
⁄
8
21 4
BW4AAH000181 OIL WATER 85.1 1.50 181,000 157,000 36 19
5
⁄
8
21 4
BW4AAH000147 OIL WATER 86.1 1.20 147,000 128,000 36 19
5
⁄
8
24
1
⁄
4
5
BW4AAH000210 OIL WATER 84.8 1.75 210,000 183,000 36 19
5
⁄
8
24
1
⁄
4
5
BW4AAH000239 OIL WATER 84.0 2.00 239,000 209,000 36 19
5
⁄
8
24
1
⁄
4
5
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×
× ×