how evolutions in communications networks and fuel … · how evolutions in communications networks...
TRANSCRIPT
Copyright 2017, Plug Power Inc.
April 20th, 2017
How Evolutions in
Communications Networks and
Fuel Cell Power Have Changed
the Site ParadigmDarin Painter
2
Technology Evolution
• Fuel cell technology and solutions have evolved substantially since they were first used in telecom 12 years ago.
• The fuel cell communications market has grown to thousands of sites located in 46 U.S. States and dozens of other countries.
• Currently, every major domestic carrier and many rural carriers and first responders utilize fuel cells in their networks to provide backup power.
• Benefits of fuel cells you should know about:
2Operational
Simplicity
1Economic
Savings
3Sustainable
Power
3
How Does a PEM Fuel Cell Work?
• Provides 100% rated power as long as it has fuel
• Run time determined by quantity of fuel storage (like a generator)
• Uses an electrolyte
• No moving parts
• Twice as efficient as fuel combustion
• The only outputs are DC power, warm-moist air, and a small
amount of pure liquid water
4
e-
e-
e-
e-
H+
H+e-H+
H+
H+
H+
H+
+ H -
H
H
O
O2H2
O
OxygenMolecules
Electrical Load
Water molecules forming
Catalyst/ElectrodeProton exchange
membrane electrolyteCatalyst/Electrode
HydrogenMolecules
Electrons
from
Hydrogen
PEM Fuel Cell Process
H2
5
GenSure Basic Architecture
AIR EXHAUSTAIR INTAKE
GenSure E-Series
H2O Out
H2 INPUT
DC POWER OUT/IN
FRONT REAR
6Plug Power Confidential and Proprietary.
Site Power System
• Simple DC Bus Connection
• Connects on the Load Side of Meter
• Parallel to Battery and Rectifier
• Fuel Cell Dimensioned for Power
• Hydrogen Dimensioned for Energy
• Indoor or Outdoor Mounting
• Load Following
• Fault-Tolerant
• Efficiency and Power Reduction
• New technology in telecom gear
• More efficient power conversion
• Cooling solutions
Simple maintenance and fewer site visits mean up to 84% lower operational costs when
compared to combustion generators.
Utility
Feed
Fuel Cell
Battery
Equipment
Load
Rectifier
AC
Panel
DC
Bus
Meter
7
GenSure E-Series
GenSure E-200™ Fuel Cell• 200W in a 2U 19” rack• 12, 24, 36 or 48VDC• Scalable to 600W in single enclosure
GenSure E-1100™ /1100v™ Fuel Cell• 1,100W in a 4U 19” rack• 1,100W vertical mount (E-1100v only)• 24 or 48VDC• Scalable to 4.4W in 40” Cabinet (E-1100 only)
GenSure E-2500™ Fuel Cell• 2,500W in a 8U 23” rack• 24 or 48VDC• Scalable to 10kW in 72” Cabinet
8Plug Power Confidential and Proprietary.
E-Series Cabinet Configurations
400W Enclosure with
55kWh H2 Storage
5kW Enclosure with
55kWh H2 Storage
4.4kW Enclosure with
167kWh H2 Storage in HSM9
E-2500™ Fuel Cell
23” Indoor Rack
E-1100™ Fuel Cell
19/23” Indoor Rack
E-200™ Fuel Cell
19/23” Indoor Rack
600W Enclosure with
8kWh H2 Storage
10kW Enclosure with
300kWh H2 Storage in HSM16
4.4kW Enclosure with
55kWh H2 Storage
E-200™
E-1100™
E-2500™
9
Typical Outdoor Installations
• Pad/Platform Mounting
• Cylinder Exchange or Refillable
• No Emissions
10
Typical Indoor Installations
• Shelter or Equipment Room Fuel Cell
• Indoor or Outdoor Fuel Storage
• Indoor: No external impact to site
• Outdoor : Simple Fueling & Maintenance
Accessibility
• No Emissions
Economic Savings: A cost-saving, space-
saving integrated power solution. 1
12
Capital Cost & TCO
• Lower capital expense for backup power equipment
• Reduced maintenance of fuel cell relative to combustion generators
Reduced Footprint
• Lower ground space lease cost – recurring expense
• Greater applicability to larger number of existing locations
Speed to Deploy
• Permitting challenges increasing for combustion generators
• Simplified deployment
• Reduction of on-site backup power integration / expense
Enhanced Intelligence
• Integrated SNMP monitoring / alarming
• Integrates w / IP based radio equipment
Integrated OSP Solution Drivers
Plug Power’s Integrated solution equips telecommunications customers with a reliable single cabinet solution for their
network power and communications equipment, providing customers with a reduction in capital and operational expenses
at each site.
13
Integrated OSP Solution
HSM-16
300 kW-hr
7 day runtime @
1.8 kW loadFuel Cell
& Battery
Power,
Radio,
Backhaul,
MW, &
SPD
Integrated Cabinet
2 Environments
Upper Compartment:
HEX
Lower Compartment:
Ventilated
14
Integrated OSP Solution
• Lower installation cost
• Lower ground space lease cost
• Simplified deployment
• Reduction of on-site backup power
integration / expense
Site Footprint Improvement
15
Integrated OSP Solution
• Reduced maintenance
• Hardened outdoor cabinets
• Temps from -40oC to +50oC / -40oF to 122oF
• Multiple options for a variety of power and runtime requirements
• Enhanced intelligence
System Configuration: Network Hardening
Utility
Feed
Fuel Cell
Battery
RectifierAC
Panel
DC
Bus
Meter
Data Comm
Microwave
LTE Radio
Telco/Lease
HVAC
Ancillary
Remote Radio
Disconnect
H2 Storage
Operational Simplicity for a Hardened
Network2
17
Remote Operations Capabilities
Customer
NOC
Monitoring
• Active Fuel Level Monitoring
• Automated Fuel Service Options
• M2M via SNMP
• Active Alarm Monitoring
• Remote Testing
• Secure Data Transfer Options
Fuel Service
Customer’s Distributed
Fuel Cell Network
IP
Network
Fuel Cell #1
Fuel Cell #2
Fuel Cell #n
Connectivity
• Ethernet/IP Network
• USB
• Modem – per Operator standards
CDMA/GSM/GRPS
• Adaptors
• Local Display
Secure M2M or
encoded data
transfer
18
GenFuel for Stationary Markets
Complete Fuel Service Offering
• Complete support services• Initial fueling
• Refueling
• Disaster recovery
• Preventive maintenance
• Live call center 24x7x365
• All fuel logistics handled for customer
• Disaster recovery support• Partnerships with service companies for delivery
• Agreements in place for fuel sourcing• Leverage Plug Power assets where available
• Remote monitoring is available or Customer NOC dispatched
• Services offered driven by project commitment
19
Bulk Hydrogen Availability
20
261
Cu. ft
60”
Common Cylinder Sizes
197
Cu. ft
D.O.E. Hydrogen Safety On-Line Course:
http://www.hydrogen.energy.gov/firstresponders.html9 kWh140 lbs261 cu-ft9” x 60”
7 kWh125 lbs197 cu-ft9” x 56”
3 kWh65 lbs80 cu-ft6” x 33”
EnergyWeightCapacitySize
Cylinder Sizes:
Cylinder Supply & Delivery
Large distribution infrastructure
• Thousands of locations nationally
Proven technology
• Standards established for siting & delivery
Capacity / run time dependent on:
• Number of Cylinders
• Cylinder Size
• Cylinder Pressure
21
GenFuel Cylinder-Exchange Coverage
• 3000+ branch industrial gas distribution locations
• Intermediate fuel storage locations can be established as needed
for limited coverage areas
Sample Industrial Gas
Supplier Locations
22
Hydrogen Fuel Comparisons - Safety
Hydrogen Properties• Rapidly disperses - the lightest element
• Colorless, odorless, tasteless, & non-toxic
• Flammable from 4% - 75% in air
H
Hydrogen car Gasoline car
The maximum temperature
inside the back window of the
hydrogen car was only 67°F!
D.O.E. Hydrogen Safety On-Line Course:
http://www.hydrogen.energy.gov/firstresponders.html
NFPA 2: This code provides fundamental safeguards for the
generation, installation, storage, piping, use, and handling of
hydrogen in compressed gas (GH2) form or cryogenic liquid
(LH2) form
23
Per unit energy content of the fuel measured in Btu’s
Hydrogen Fuel Comparisons - Energy
3.5 Gallons of Diesel
(1 Gallon = 128,450 Btu)5.3 Gallons of Propane
(1 gallon = 84,950 Btu)
Hydrogen Volume Diesel Equivalent Gallons Propane Equivalent Gallons
1 Cylinder (260 Cubic Feet) 0.6 0.9
Fuel Wing (6 Cylinders) 3.5 5.3
HSM-16 Refillable Module 18.4 27.8
6 Cylinders of Hydrogen
(1 Cylinder = 75,400 Btu)
24
Backup Power Options
Fuel Cells vs. Generators
• Fuel Cells - Fewer mechanical parts /
increased availability
• Fuel Cells - Lower cost of ownership /
reduced maintenance
• Fuel Cells - Hydrogen has unlimited shelf
life / greater reliability
• Fuel Cells - Zero emission technology
• Fuel Cells - Lower incidence of theft
• Fuel Cells - Remote management capable
Sustainable Power Moving the Network
into the Future - Today3
26
Zero-Emission Power
Feature Diesel Generator Plug Power GenSure fuel cells
Overview Internal combustion diesel generators deliver medium quality
electrical power by burning fossil fuel and using it to drive a
rotation generator
Fuel cells offer clean, continuous high quality
electrical power resulting from an
electrochemical reaction with hydrogen and
oxygen from ambient air
Emissions High levels of NOx, CO2, CO and particulate matter emitted.
Fuel is toxic to environment when spilled.
Clean – heat and water are the only emissions
Noise Exhaust and mechanical noise Silent, except for fan noise. Fuel cell noise
tends to be 10 - 20db lower than diesel
generator noise.
Conclusions
28
Conclusions
• Fuel cells offer a highly-reliable, clean, cost-effective solution
for a growing number of telecom applications.
• Evolutions in these 3 areas are providing solid reasons for
carriers and contractors to expand adoption of hydrogen and
fuel cells.
The world is moving – join us and move boldly into the future.
2Operational
Simplicity
1Economic
Savings
3Sustainable
Power
Corporate Headquarters
968 Albany Shaker Road, Latham, NY 12110
West Coast
15913 E. Euclid Avenue, Spokane, WA 99216