hornet hp hornet hp rld/rlw - amerlux.com · available for use with rem, cp or ic options) model...

11
Passion. Power. Performance. LIT-2007 03/16/18 Page 1 of 11 Amerlux reserves the right to change details that do not affect overall function and performance. Amerlux®, LLC 178 Bauer Drive, Oakland, NJ 07436 P: 973-882-5010 F: 973-882-2605 amerlux.com Hornet HP RLD/RLW Watts Delivered Lumens LPW CBCP Color Temp 16 1,234 77.1 3,561 3000K-83 23 1,645 72.2 4,748 3000K-83 Features Hornet Lensed Downlights are the perfect choice for all general lighting needs. Available in Round or Square apertures, these fixtures meet the needs of commercial and hospitality markets. Optional Solite lensing provides whisper quiet aesthetics. Also available in knife-edge trimless and remodeler. Complementing Hornet Lens Wall Wash fixture available. Product Overview Type: Recessed Round Lensed Downlight/Wall Wash Wattage: 16, 23 Lumen Output: 1,645 max; 72.2 lm/W (30SOL optic) CBCP: 4,748 max (30SOL optic) Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) 90+ typ. (2200K, 2700K, 3000K, 3500K, 4000K) CrispWhite & 3K Class A available Dimming: TRIAC & ELV (120V/277V) - 5% Dim Lutron A Series (120V/277V), 3-wire/EcoSystem Hi-lume® - 1% dim Lutron H Series (120V/277V), EcoSystem, Hi-lume® - 1% dim with soft on, fade to black 0-10V (120V/277V) - 1% Dim DALI (120V/277V) - 1% Dim Fixture Type PROJECT: TYPE: Hornet ® HP Round Lensed Downlight/ Wall Wash Round/Square New Construction Remodeler Trim Trimless Yes Yes Yes Yes Yes Performance Chart Data is based on 3000K-83 IES files available on website Data is based on 30SOL optic. All wattage and LPW includes 2W thermal protector Trimless version Wall Wash See separate spec sheet for Square Electrical Data 16W 23W System Watts Amps System Watts Amps 120V 16 0.13 23 0.19 277V 16 0.06 23 0.08 Electronic constant current LED driver Includes thermal protector, 2W power consumption 5 5 Title 24 Compliant Downlight

Upload: truongque

Post on 04-Sep-2018

240 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

LIT-2007 • 03/16/18 • Page 1 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Ho

rne

t H

P R

LD

/RL

W

Watts

Delivered

Lumens LPW CBCP

Color

Temp

16 1,234 77.1 3,561 3000K-83

23 1,645 72.2 4,748 3000K-83

FeaturesHornet Lensed Downlights are the perfect choice for all general lighting

needs. Available in Round or Square apertures, these fixtures meet the needs

of commercial and hospitality markets. Optional Solite lensing provides

whisper quiet aesthetics. Also available in knife-edge trimless and remodeler.

Complementing Hornet Lens Wall Wash fixture available.

Product OverviewType: Recessed Round Lensed Downlight/Wall Wash

Wattage: 16, 23

Lumen Output: 1,645 max; 72.2 lm/W (30SOL optic)

CBCP: 4,748 max (30SOL optic)

Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K

CRI: 83 typ. (2700K, 3000K, 3500K, 4000K)

90+ typ. (2200K, 2700K, 3000K, 3500K, 4000K)

CrispWhite & 3K Class A available

Dimming: TRIAC & ELV (120V/277V) - 5% Dim

Lutron A Series (120V/277V), 3-wire/EcoSystem

Hi-lume® - 1% dim

Lutron H Series (120V/277V), EcoSystem, Hi-lume® -

1% dim with soft on, fade to black

0-10V (120V/277V) - 1% Dim

DALI (120V/277V) - 1% Dim

Fixture Type

PROJECT: TYPE:

Hornet® HPRound Lensed Downlight/

Wall Wash

Round/Square New Construction Remodeler Trim Trimless

Yes Yes Yes Yes Yes

Performance Chart

Data is based on 3000K-83 IES fi les available on website

Data is based on 30SOL optic.

All wattage and LPW includes 2W thermal protector

Trimless version

Wall Wash

See separate spec sheet for Square

Electrical Data

16W 23W

System

Watts Amps

System

Watts Amps

120V 16 0.13 23 0.19

277V 16 0.06 23 0.08

Electronic constant current LED driver

Includes thermal protector, 2W power consumption

55Title 24Compliant

Downlight

Page 2: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 2 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet® HPRound Lensed Downlight/Wall Wash

Model For New Construction HDL-HP-R-NC-A17† (New Construction)

HDL-HP-R-CP-A17† (Chicago Plenum (CCEA) housing)

HDL-HP-R-IC-A17†* (Insulated Ceiling/air tight, 16W only)

For Existing Ceilings HDL-HP-R-REM-A17† (Remodeler)

Style T - trimmed

TL - trimless

Wattage 16*

23 (not available for use with IC housing)

Voltage 120

277

120/277 (for use with IC housing only)

Driver (for non-dimming, select LE/TE option)

LE/TE* - TRIAC/ELV dimming

HILUME-A - Lutron Hi-lume® A Series, 3-wire/EcoSystem,

Hi-lume®, 1% dim

HILUME-H - Lutron Hi-lume® H Series, EcoSystem

Hi-lume®, 1% dim with soft on, fade to black

0-10V* - 0-10V dimming; 1% dim

DALI - DALI dimming, 1% dim

Options/Accessories EM - emergency battery pack with remote test switch (not

available for use with REM, CP or IC options)

Model HDL-HP-RLD-A17† (lensed downlight)

HDL-HP-RLW-A17† (lensed wall wash)

Style T - trimmed

TL - trimless

Finish Trimmed Trimless MBW - matte black, white fl ange MB - matte black

MWW - matte white, white fl ange MW - matte white

SLVW - matte silver, white fl ange SLV - matte silver

MBB - matte black, black fl ange

SLVS - matte silver, silver fl ange

Beam Spreads (not required with RLW version)

30SOL - 30º beam with solite lens

50SOL - 50º beam with solite lens

65SOL - 65º beam with solite lens

75SAT - 75º beam with satin ice lens

Color Temp 83 CRI 90+ CRI 27 - 2700K-83 229 - 2200K-90+ CRISP - CrispWhite

30 - 3000K-83 279* - 2700K-90+ 3CLA - 3K Class A

35 - 3500K-83 309* - 3000K-90+

40 - 4000K-83 359 - 3500K-90+

409 - 4000K-90+

Options/Accessories WET - wet location (not available for use with trimless

style)

* Title 24 Compliant

† The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not

changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for

explanations of changes.

1

1

2

2

3

3

4

4

5

5

6

6

1

1

2

2

3

3

4

4

5

5

6

6

Housing/Frame Ordering Information

Trim Ordering Information

Page 3: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 3 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet® HPRound Lensed Downlight

Specifi cations

Application

Retail and commercial ambient or wall wash lighting

Construction

20 ga. galvanized steel frame

18 ga. galvanized steel splice housing and hanger brackets

(not for Remodeler version)

Cast aluminum plaster frame with perforated face (for

trimless version only)

Die-cast optical housing and trim

Die-cast heat sink

Optical

Lens Options (for RLD version): Satin Ice lens for maximum source concealment and

wide distribution with a visually “hotter” aperture.

Solite lens for maximum effi cacy and a visually quieter

aperture. 30º, 50º and 65º beam spread options.

Visually best with SLV refl ector fi nish.

Beam spreads (for RLD version): 30SOL - 30º beam with solite lens

50SOL - 50º beam with solite lens

65SOL - 65º beam with solite lens

75SAT - 75º beam with satin ice lens

Wall Wash: Engineered nano technology lens provides high

transmission while concealing LED image

LED

Color Temp Options: 2200K, 2700K, 3000K, 3500K, 4000K

CRI: 83 typ. (2700K, 3000K, 3500K, 4000K)

90+ typ. (2200K, 2700K, 3000K, 3500K, 4000K)

CrispWhite* and Class A** 3000K LEDs available

R9 Values: 11 (83 CRI), 55 (92 CRI)

Binning: 3 MacAdam (SDCM)

Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs

*CrispWhite: CrispWhite Technology delivers the warmth of colors expected

from a high 90 CRI solution but also creates the natural crisp white color

that is pleasing to the eye. It creates the most impactful lighting ever

available, by revealing the richest whites and vibrant colors that pop.

**Class A LED: Class A LED’s have a CRI > 80 and a GAI > 80. CRI defi nes

color “Naturalness” and GAI defi nes color “Saturation.” Both being high

delivers rich colors and pure whites.

Electrical

Wattage: 16, 23

Electronic constant current LED driver, 120V/277V input

This product complies with IEEE C62.41 for surge endurance up to

2.5KV. Amerlux® recommends using additional surge protection

with this unit (supplied by others), surge and over voltage damage is

not covered under warranty.

Note: Drivers are universal but thermal protector is voltage

specifi c

Drivers

LE/TE - Leading Edge, TRIAC, forward phase/Trailing Edge,

ELV, reverse phase

0-10V, Lutron and DALI systems available

See pages 10-11 for more dimming information

Finish

Powder coat paint/wet paint

Consult factory for custom fi nishes

Mounting

26” Hanger bars included (except for Remodeler versions)

Consult factory for hanger bars greater than 26”

Trimmed Fixture:

For use in grid or sheetrock ceilings, 5/8” - 2” (1” for RLW

trims) standard

Trimless Fixture:

For use in sheetrock ceilings, max ceiling thickness 5/8”

Certifi cations

CSA damp as tested to UL 1598 standards

CP - Chicago Plenum (CCEA) option

IC/AT rated (optional, 16W only)

Title 24 Compliant (see ordering page for options that apply)

Damp location

Wet location option

Warranty

5 year limited warranty

Emergency Battery Pack (EM)

Powers fi xture at 5.1 watts (approx. 400 Lm) for 90 minutes

(not for use with REM, CP or IC/AT versions)

Page 4: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 4 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet® HPRound Lensed Downlight/Wall Wash

Hornet HP Round Lensed Downlight:

Hornet HP Round Lensed Wall Wash:

Ceiling cut out: 4” dia.

Ceiling cut out: 4” dia.

14 1/2” min - 26” max 11 1/2”

7 3 / 4

”12

1 / 8”

4”7 1/2”

Trimmed

Trimmed

12 5 / 16

6”

Emergency Battery Pack (EM) option

Ø3 1/2” Ø3 1/2”

Ø3 1/2”Ø3 1/2”

Ø4 3/8”

Ø3 1/2”

Ø2 7/16”

Ø4 3/8”

Ø3 1/2”

Ø4 3/8”

Ø4 3/8”

Ø4 3/8”Ø4 3/8”

3 7 / 8

3 7 / 8

”3

7 / 8”

3 7 / 8

”3

1 / 8”

3 1 / 8

1/8”

1/8”

11 1/2”

7 3/4”

13 5/16”

13 3 /

16”

11 5 /

8”

Optional CP or IC/AT housing

13 1/4”

13 1/4”11 5/8”

7 5/8”

7 3/16”7 13/16”

13 3/8”

5/8”

5/8”

Page 5: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 5 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet HP Round Lensed Downlight Trimless:

Hornet HP Round Lensed Wall Wash Trimless:

Ceiling cut out: 4 1/2” dia.

Ceiling cut out: 4 1/2” dia.

14 1/2” min - 26” max 11 1/2”

7 3 / 4

”12

1 / 8”

4”7 1/2”

12 5 / 16

6”

Emergency Battery Pack (EM) option

Ø3 1/2” Ø3 1/2”

Ø3 1/2”Ø3 1/2”

Ø3 9/16” Ø3 9/16”

Ø3 9/16”Ø3 9/16”

3 7 / 8

3 7 / 8

”3

7 / 8”

3 7 / 8

”3

1 / 8”

3 1 / 8

1/8”

1/8”

11 1/2”

7 3/4”

13 5/16”

13 3 /

16”

11 5 /

8”

Optional CP or IC/AT housing

13 1/4”

13 1/4”11 5/8”

7 5/8”

7 3/16”7 13/16”

13 3/8”

5/8”

5/8”

Plaster Frame Installation Detail (for trimless fi xture only)

1. Refl ector Trim

2. Aperture plate

3. Ceiling ⅝”

4. Cast Aluminum Plaster Frame

5. Plaster Skim Coat (by others)

6. 6-32 Type F Thread Cutting Screw

123

456

New Construction

Ø3 9/16” Ø3 1/2”

Ø2 7/16”

Ø3 9/16” Ø3 1/2”

Hornet® HPRound Lensed Downlight/Wall Wash

Page 6: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 6 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet® HPRound Lensed Downlight/Wall Wash

Hornet HP Round Lensed Downlight Remodeler:

Hornet HP Round Lensed Wall Wash Remodeler:

AB

8 1/16”

2 1/4”4”

3 5/16”Ø6 1/4”

Ceiling cut out: 4” dia.

Ceiling cut out: 4” dia.

Ø3 1/2”Ø4 3/8”

3 7 / 8

”3

1 / 8”

1/8”5/8”

Ø3 1/2”Ø4 3/8”

3 7 / 8

”3

1 / 8”

1/8”5/8”

STRUCTURE

5 1/2”Min. Clearance

RLD-REM RLW-REM

A 7 9/16” 7 9/16”B 13 5/16” 13 5/16”

Ø3 1/2”

Ø2 7/16”

Ø4 3/8”

STRUCTURE

5 1/2”Min. Clearance

Ø3 1/2”

Ø4 3/8”

Page 7: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 7 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

Hornet® HPRound Lensed Downlight/Wall Wash

Hornet HP Round Lensed Downlight Remodeler Trimless:

Hornet HP Round Lensed Wall Wash Remodeler Trimless:

AB

8 1/16”

2 1/4”4”

3 5/16”Ø6 1/4”

Ceiling cut out: 4 1/2” dia.

Ceiling cut out: 4 1/2” dia.

Ø3 1/2”Ø3 9/16”

3 7 / 8

”3

1 / 8”

1/8”5/8”

Ø3 1/2”Ø3 9/16”

3 7 / 8

”3

1 / 8”

1/8”5/8”

Plaster Frame Installation Detail (for trimless fi xture only)

1. Refl ector Trim

2. Aperture plate

3. Ceiling ⅝”

4. Cast Aluminum Plaster Frame

5. Plaster Skim Coat (by others)

6. 6-32 Type F Thread Cutting Screw

431

265

Remodeler

STRUCTURE

5 1/2”Min. Clearance

RLD-REM-TL RLW-REM-TL

A 6 13/16” 7”B 12 15/16” 13 5/16”

Ø3 9/16”Ø3 1/2”

Ø2 7/16”

STRUCTURE

5 1/2”Min. Clearance

Ø3 9/16” Ø3 1/2”

Page 8: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 8 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

23W LED, 3000K

Application Data:

D

W

L

FC

Candelas at Nadir

Deg Candela

0 875

5 866

15 797

25 653

35 455

45 271

75º Satin Ice Lens

LTL #631077

Lumens: 1,310

0o Aiming Angle

Horizontal

Footcandles

75

° S

ati

n Ic

e

Le

ns

D FC L W

5.0’ 36 5.1 5.1

7.5’ 16 7.7 7.7

10.0’ 9 10.3 10.3

12.5’ 6 13.5 13.5

Notes and Defi nitions:

Beam spread is to 50% center beam candlepower (CBCP).

D=Distance to floor or wall.

FC=Footcandles on floor or wall at center beam aiming location.

L=Eff ective Visual Beam length in feet (50% of maximum footcandle level).

W=Eff ective Visual Beam width in feet (50% of maximum footcandle level).

CB=Distance across or down to center beam location.

0

90

180

30

150

60

120

250

500

750

Candelas at Nadir

Deg Candela

0 4748

5 4478

15 2354

25 877

35 126

45 42

30º Solite Lens

LTL #1191156

Lumens: 1,645

0 15 30

45

60

75

90

1250

2500

3750

5000

Candelas at Nadir

Deg Candela

0 2236

5 2150

15 1624

25 1063

35 367

45 67

50º Solite Lens

LTL #1191155

Lumens: 1,513

0 15 30

45

60

75

90

500

1000

1500

2000

0o Aiming Angle

Horizontal

Footcandles

30

° S

oli

te

Le

ns

D FC L W

5.0’ 190 2.7 2.7

7.5’ 85 3.7 3.7

10.0’ 48 5.1 5.1

12.5’ 31 6.3 6.3

0o Aiming Angle

Horizontal

Footcandles

50

° S

oli

te

Le

ns

D FC L W

5.0’ 90 3.7 3.7

7.5’ 40 5.5 5.5

10.0’ 23 7.3 7.3

12.5’ 15 9.1 9.1

FIXTURE DATA: (Complete photometric data (.ies format) available upon request)

MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website)

Hornet® HPRound Lensed Downlight/Wall Wash

Hornet HP Round Lensed Downlight:

Wattage: 16W 23W

Factor: 0.69 1.0

CCT: 2700K-83 3000K-83 3500K-83 4000K-83

Factor: 0.96 1.0 1.02 1.04

CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ 4000K-90+ CRISP 3CLA

Factor: 0.71 0.80 0.83 0.87 0.90 0.65 0.75

Page 9: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 9 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

FIXTURE DATA: (Complete photometric data (.ies format) available upon request)

Wattage: 16W 23W

Factor: 0.69 1.0

MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website)

Application Data:

23W 3000K-83

Lumens: 1558

ZONAL LUMEN SUMMARY

Zone Lumens %Fixt

0-30 683 43.85

0-40 1005 64.53

0-60 1411 90.60

0-90 1558 100.00

40-90 553 35.47

60-90 146 9.40

90-180 0 0.00

0-180 1558 100.00

Luminaire Effi cacy: 68.9 Lm/W

LTL# 631078

0.5’ 48 50 50 50 48

1.5’ 94 99 100 99 91

2.5’ 88 94 95 94 88

3.5’ 60 66 68 66 61

4.5’ 40 44 46 45 41

5.5’ 28 31 32 31 29

6.5’ 21 23 23 23 21

7.5’ 16 17 18 17 16

0.5’ 37 40 37 40 37 40 36

1.5’ 72 77 75 78 74 77 72

2.5’ 69 73 74 75 74 73 69

3.5’ 48 52 54 54 54 52 49

4.5’ 33 36 37 38 37 36 33

5.5’ 23 26 27 27 27 26 24

6.5’ 17 19 20 20 20 19 18

7.5’ 14 15 16 16 16 15 14

0.5’ 21 23 22 23 23 22 22

1.5’ 48 51 51 52 51 51 48

2.5’ 56 59 61 61 61 60 56

3.5’ 47 51 52 53 53 51 47

4.5’ 36 39 41 41 41 39 36

5.5’ 27 29 31 31 31 29 27

6.5’ 21 22 24 24 24 23 21

7.5’ 16 18 19 19 19 18 16

1.5’

2’

2’

2’

2’

1.5’

Dis

tan

ce

fro

m c

eil

ing

Dis

tan

ce

fro

m c

eil

ing

Dis

tan

ce

fro

m c

eil

ing

Footcandles on Wall

1.5 Feet from Wall

1.5 Feet from Wall

2 Feet from Wall

Footcandles are average and rounded off .

Data for multiple units are based

on a minimum of fi ve units.

CCT: 2700K-83 3000K-83 3500K-83 4000K-83

Factor: 0.96 1.0 1.02 1.04

CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ 4000K-90+ CRISP 3CLA

Factor: 0.71 0.80 0.83 0.87 0.90 0.65 0.75

0

9090

180

300

150150

6060

120120

450

900

ACROSS45

ALONG

Hornet® HPRound Lensed Downlight/Wall Wash

Hornet HP Round Lensed Wall Wash:

Page 10: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 10 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

DIMMING COMPATIBILITY:

Amerlux® Hornet fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general

compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration

(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.

TRIAC (Forward Phase) DIMMING (Standard)

Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. Best for retrofi t applications where TRIAC

dimmers are installed.

Notes:

• 120V or 277V*

• Dims down to less than 5% light output (most cases)

• Consult Dimming manufacturer for installation

instructions - DO NOT SHARE NEUTRALS!

• Must meet dimmer Minimum Load Requirements per

dimming manufacturer

Lutron “Diva”

Lutron “Nova-T”

Lutron “Maestro”

Lutron “Vareo”

Lutron “Skylark”

Lutron “GP” Panel

Lutron Grafi k Eye QS

Compatible Dimmers

Wall Box (Incandescent Style, Wattage as required) Central System

TRIAC Wiring Diagram

ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard)

Utilizes specialized “ELV” dimmers. Best for New Construction applications

Notes:

• 120V or 277V*

• Dims down to less than 5% light output (most cases)

• Consult Dimming manufacturer for installation

instructions - DO NOT SHARE NEUTRALS!

• Must meet dimmer Minimum Load Requirements

Lutron “Diva”

Lutron “Nova-T”

Lutron “Maestro”

Leviton “Surslide”

Lutron “Vareo”

Lutron “Skylark”

Leviton “Vizio”

Lutron “GP” Panel with PHPM-PA

Interface

Lutron Grafi k Eye QS with

PHPM-PA Interface

Compatible Dimmers

Wall Box (ELV Style) Central System

0-10V - DIMMING (-0-10V Option)

Integrates into a variety of building management and daylighting controls

Notes:

• 120V or 277V*

• Dims down to 1% light output

• Requires interface to turn off power to driver

• Consult Dimming manufacturer for installation

instructions - DO NOT SHARE NEUTRALS!

Lutron “Diva” - DVTV with PP-

120H Interface

Leviton Renoir II 0-10v Lutron Grafi k Eye with

GRX-TVI Interface

Compatible Dimmers

Wall Box Central System

Black

White

Green

Red

Black

V+

V-

Driver

Line

Neutral

TRIACDimmingControl Neutral

ELV Wiring Diagram

Black

White

Green

Red

Black

V+

V-

Driver

Line

Neutral

ELVDimmingControl Neutral

0-10V Wiring Diagram

Gray

Purple

Black

White

Green

Driver

Line

Neutral

0-10VDimmingControl

Neutral

Red

Black

V+

V-

0-10V (-)

0-10V (+)

Ground

Ground

Ground

Ground

Ground

Ground

Switched Hot

Line

Line

Notes:

* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.

Please refer to 277V dimming installation instructions for 277V wiring diagrams.

--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---

Hornet® HPRound Lensed Downlight/Wall Wash

Page 11: Hornet HP Hornet HP RLD/RLW - amerlux.com · available for use with REM, CP or IC options) Model HDL-HP-RLD-A17† (lensed downlight) HDL-HP-RLW-A17† (lensed wall wash) Style T

Passion. Power. Performance.

PROJECT: TYPE:

Ho

rne

t H

P R

LD

/RL

W

LIT-2007 • 03/16/18 • Page 11 of 11

Amerlux reserves the right to change details that do not aff ect overall function and performance.

Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

DIMMING COMPATIBILITY:

Amerlux® Hornet fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general

compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration

(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.

LUTRON A-SERIES HI-LUME / ECOSYSTEM (-HILUME-A option)

Integrates into Lutron EcoSystem building management

Notes:

• 120V or 277V*

• Dims down to less than 5% light output

• May use 3-Wire or EcoSystem Control

• Consult Dimming manufacturer for installation

instructions - DO NOT SHARE NEUTRALS!

3-Wire Wiring Diagram

EcoSystem Digital Control Wiring Diagram

Compatible Dimmers

Wall Box (3-Wire Fluorescent)

DIVA

Maestro

Nova T

Vareo

Central System

Lutron EcoSystem compatible controls

EMERGENCY DIMMING (-EM OPTION)

Wiring Diagram

Unswitched Hot

Common

Wall Switch

AC LEDDriver

LED Load LEDLED

OutputOutput

WhiteBlueBlack

ThermalProtector

WhiteBlack

WT/Red

WT/BLK

Blue

Yellow/BLK

Yellow

Violet

Brown

TestSwitch

ConverterConnector

2W-ITSEMERGENCY

LED

DRI

VER

Flex

A

Flex

B

Violet

Brown

White

Red

White Black

Purple Stripe

Purple

Black

White

Green

Red

Black

V+

V-

Driver

Line

Neutral

ECOSYS Bus

EcoSystemDimmingControl

Orange

E2

E1

Dimmed Hot

E1

E2

Ground

Purple Stripe

Purple

Black

White

Green

Red

Black

V+

V-

Driver

Line

Neutral

Cap unused ECOSYS wires

3-Wire Phase

DimmingControl

Orange Dimmed Hot

Ground Neutral

Neutral

Ground

E1

E2

(Cap off Orange wire)

Switched Hot

Switched Hot

DALI DIMMING (-DALI OPTION)

Digital control protocol allows individual fi xture control

Notes:

• 120V - 277V*

• Dims down to 1% light output in most cases

DALI Wiring Diagram

Compatible Dimmers

Wall Box (3-Wire Fluorescent)

Leviton CD250 Controller

Central System

Dynalite

Fifth Light

Purple

Purple/WT

Black

White

Green

Red

Black

V+

V-

Driver

Line

Neutral

DALI Bus

DALIDimmingControl

Ground

Neutral

Line

--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---

Notes:

* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.

Please refer to 277V dimming installation instructions for 277V wiring diagrams.

Hornet® HPRound Lensed Downlight/Wall Wash