hornet hp hornet hp rld/rlw - amerlux.com · available for use with rem, cp or ic options) model...
TRANSCRIPT
Passion. Power. Performance.
LIT-2007 • 03/16/18 • Page 1 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Ho
rne
t H
P R
LD
/RL
W
Watts
Delivered
Lumens LPW CBCP
Color
Temp
16 1,234 77.1 3,561 3000K-83
23 1,645 72.2 4,748 3000K-83
FeaturesHornet Lensed Downlights are the perfect choice for all general lighting
needs. Available in Round or Square apertures, these fixtures meet the needs
of commercial and hospitality markets. Optional Solite lensing provides
whisper quiet aesthetics. Also available in knife-edge trimless and remodeler.
Complementing Hornet Lens Wall Wash fixture available.
Product OverviewType: Recessed Round Lensed Downlight/Wall Wash
Wattage: 16, 23
Lumen Output: 1,645 max; 72.2 lm/W (30SOL optic)
CBCP: 4,748 max (30SOL optic)
Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K
CRI: 83 typ. (2700K, 3000K, 3500K, 4000K)
90+ typ. (2200K, 2700K, 3000K, 3500K, 4000K)
CrispWhite & 3K Class A available
Dimming: TRIAC & ELV (120V/277V) - 5% Dim
Lutron A Series (120V/277V), 3-wire/EcoSystem
Hi-lume® - 1% dim
Lutron H Series (120V/277V), EcoSystem, Hi-lume® -
1% dim with soft on, fade to black
0-10V (120V/277V) - 1% Dim
DALI (120V/277V) - 1% Dim
Fixture Type
PROJECT: TYPE:
Hornet® HPRound Lensed Downlight/
Wall Wash
Round/Square New Construction Remodeler Trim Trimless
Yes Yes Yes Yes Yes
Performance Chart
Data is based on 3000K-83 IES fi les available on website
Data is based on 30SOL optic.
All wattage and LPW includes 2W thermal protector
Trimless version
Wall Wash
See separate spec sheet for Square
Electrical Data
16W 23W
System
Watts Amps
System
Watts Amps
120V 16 0.13 23 0.19
277V 16 0.06 23 0.08
Electronic constant current LED driver
Includes thermal protector, 2W power consumption
55Title 24Compliant
Downlight
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 2 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet® HPRound Lensed Downlight/Wall Wash
Model For New Construction HDL-HP-R-NC-A17† (New Construction)
HDL-HP-R-CP-A17† (Chicago Plenum (CCEA) housing)
HDL-HP-R-IC-A17†* (Insulated Ceiling/air tight, 16W only)
For Existing Ceilings HDL-HP-R-REM-A17† (Remodeler)
Style T - trimmed
TL - trimless
Wattage 16*
23 (not available for use with IC housing)
Voltage 120
277
120/277 (for use with IC housing only)
Driver (for non-dimming, select LE/TE option)
LE/TE* - TRIAC/ELV dimming
HILUME-A - Lutron Hi-lume® A Series, 3-wire/EcoSystem,
Hi-lume®, 1% dim
HILUME-H - Lutron Hi-lume® H Series, EcoSystem
Hi-lume®, 1% dim with soft on, fade to black
0-10V* - 0-10V dimming; 1% dim
DALI - DALI dimming, 1% dim
Options/Accessories EM - emergency battery pack with remote test switch (not
available for use with REM, CP or IC options)
Model HDL-HP-RLD-A17† (lensed downlight)
HDL-HP-RLW-A17† (lensed wall wash)
Style T - trimmed
TL - trimless
Finish Trimmed Trimless MBW - matte black, white fl ange MB - matte black
MWW - matte white, white fl ange MW - matte white
SLVW - matte silver, white fl ange SLV - matte silver
MBB - matte black, black fl ange
SLVS - matte silver, silver fl ange
Beam Spreads (not required with RLW version)
30SOL - 30º beam with solite lens
50SOL - 50º beam with solite lens
65SOL - 65º beam with solite lens
75SAT - 75º beam with satin ice lens
Color Temp 83 CRI 90+ CRI 27 - 2700K-83 229 - 2200K-90+ CRISP - CrispWhite
30 - 3000K-83 279* - 2700K-90+ 3CLA - 3K Class A
35 - 3500K-83 309* - 3000K-90+
40 - 4000K-83 359 - 3500K-90+
409 - 4000K-90+
Options/Accessories WET - wet location (not available for use with trimless
style)
* Title 24 Compliant
† The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not
changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for
explanations of changes.
1
1
2
2
3
3
4
4
5
5
6
6
1
1
2
2
3
3
4
4
5
5
6
6
Housing/Frame Ordering Information
Trim Ordering Information
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 3 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet® HPRound Lensed Downlight
Specifi cations
Application
Retail and commercial ambient or wall wash lighting
Construction
20 ga. galvanized steel frame
18 ga. galvanized steel splice housing and hanger brackets
(not for Remodeler version)
Cast aluminum plaster frame with perforated face (for
trimless version only)
Die-cast optical housing and trim
Die-cast heat sink
Optical
Lens Options (for RLD version): Satin Ice lens for maximum source concealment and
wide distribution with a visually “hotter” aperture.
Solite lens for maximum effi cacy and a visually quieter
aperture. 30º, 50º and 65º beam spread options.
Visually best with SLV refl ector fi nish.
Beam spreads (for RLD version): 30SOL - 30º beam with solite lens
50SOL - 50º beam with solite lens
65SOL - 65º beam with solite lens
75SAT - 75º beam with satin ice lens
Wall Wash: Engineered nano technology lens provides high
transmission while concealing LED image
LED
Color Temp Options: 2200K, 2700K, 3000K, 3500K, 4000K
CRI: 83 typ. (2700K, 3000K, 3500K, 4000K)
90+ typ. (2200K, 2700K, 3000K, 3500K, 4000K)
CrispWhite* and Class A** 3000K LEDs available
R9 Values: 11 (83 CRI), 55 (92 CRI)
Binning: 3 MacAdam (SDCM)
Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs
*CrispWhite: CrispWhite Technology delivers the warmth of colors expected
from a high 90 CRI solution but also creates the natural crisp white color
that is pleasing to the eye. It creates the most impactful lighting ever
available, by revealing the richest whites and vibrant colors that pop.
**Class A LED: Class A LED’s have a CRI > 80 and a GAI > 80. CRI defi nes
color “Naturalness” and GAI defi nes color “Saturation.” Both being high
delivers rich colors and pure whites.
Electrical
Wattage: 16, 23
Electronic constant current LED driver, 120V/277V input
This product complies with IEEE C62.41 for surge endurance up to
2.5KV. Amerlux® recommends using additional surge protection
with this unit (supplied by others), surge and over voltage damage is
not covered under warranty.
Note: Drivers are universal but thermal protector is voltage
specifi c
Drivers
LE/TE - Leading Edge, TRIAC, forward phase/Trailing Edge,
ELV, reverse phase
0-10V, Lutron and DALI systems available
See pages 10-11 for more dimming information
Finish
Powder coat paint/wet paint
Consult factory for custom fi nishes
Mounting
26” Hanger bars included (except for Remodeler versions)
Consult factory for hanger bars greater than 26”
Trimmed Fixture:
For use in grid or sheetrock ceilings, 5/8” - 2” (1” for RLW
trims) standard
Trimless Fixture:
For use in sheetrock ceilings, max ceiling thickness 5/8”
Certifi cations
CSA damp as tested to UL 1598 standards
CP - Chicago Plenum (CCEA) option
IC/AT rated (optional, 16W only)
Title 24 Compliant (see ordering page for options that apply)
Damp location
Wet location option
Warranty
5 year limited warranty
Emergency Battery Pack (EM)
Powers fi xture at 5.1 watts (approx. 400 Lm) for 90 minutes
(not for use with REM, CP or IC/AT versions)
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 4 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet® HPRound Lensed Downlight/Wall Wash
Hornet HP Round Lensed Downlight:
Hornet HP Round Lensed Wall Wash:
Ceiling cut out: 4” dia.
Ceiling cut out: 4” dia.
14 1/2” min - 26” max 11 1/2”
7 3 / 4
”12
1 / 8”
4”7 1/2”
Trimmed
Trimmed
12 5 / 16
”
6”
Emergency Battery Pack (EM) option
Ø3 1/2” Ø3 1/2”
Ø3 1/2”Ø3 1/2”
Ø4 3/8”
Ø3 1/2”
Ø2 7/16”
Ø4 3/8”
Ø3 1/2”
Ø4 3/8”
Ø4 3/8”
Ø4 3/8”Ø4 3/8”
3 7 / 8
”
3 7 / 8
”3
7 / 8”
3 7 / 8
”3
1 / 8”
3 1 / 8
”
1/8”
1/8”
11 1/2”
7 3/4”
13 5/16”
13 3 /
16”
11 5 /
8”
Optional CP or IC/AT housing
13 1/4”
13 1/4”11 5/8”
7 5/8”
7 3/16”7 13/16”
13 3/8”
5/8”
5/8”
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 5 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet HP Round Lensed Downlight Trimless:
Hornet HP Round Lensed Wall Wash Trimless:
Ceiling cut out: 4 1/2” dia.
Ceiling cut out: 4 1/2” dia.
14 1/2” min - 26” max 11 1/2”
7 3 / 4
”12
1 / 8”
4”7 1/2”
12 5 / 16
”
6”
Emergency Battery Pack (EM) option
Ø3 1/2” Ø3 1/2”
Ø3 1/2”Ø3 1/2”
Ø3 9/16” Ø3 9/16”
Ø3 9/16”Ø3 9/16”
3 7 / 8
”
3 7 / 8
”3
7 / 8”
3 7 / 8
”3
1 / 8”
3 1 / 8
”
1/8”
1/8”
11 1/2”
7 3/4”
13 5/16”
13 3 /
16”
11 5 /
8”
Optional CP or IC/AT housing
13 1/4”
13 1/4”11 5/8”
7 5/8”
7 3/16”7 13/16”
13 3/8”
5/8”
5/8”
Plaster Frame Installation Detail (for trimless fi xture only)
1. Refl ector Trim
2. Aperture plate
3. Ceiling ⅝”
4. Cast Aluminum Plaster Frame
5. Plaster Skim Coat (by others)
6. 6-32 Type F Thread Cutting Screw
123
456
New Construction
Ø3 9/16” Ø3 1/2”
Ø2 7/16”
Ø3 9/16” Ø3 1/2”
Hornet® HPRound Lensed Downlight/Wall Wash
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 6 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet® HPRound Lensed Downlight/Wall Wash
Hornet HP Round Lensed Downlight Remodeler:
Hornet HP Round Lensed Wall Wash Remodeler:
AB
8 1/16”
2 1/4”4”
3 5/16”Ø6 1/4”
Ceiling cut out: 4” dia.
Ceiling cut out: 4” dia.
Ø3 1/2”Ø4 3/8”
3 7 / 8
”3
1 / 8”
1/8”5/8”
Ø3 1/2”Ø4 3/8”
3 7 / 8
”3
1 / 8”
1/8”5/8”
STRUCTURE
5 1/2”Min. Clearance
RLD-REM RLW-REM
A 7 9/16” 7 9/16”B 13 5/16” 13 5/16”
Ø3 1/2”
Ø2 7/16”
Ø4 3/8”
STRUCTURE
5 1/2”Min. Clearance
Ø3 1/2”
Ø4 3/8”
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 7 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Hornet® HPRound Lensed Downlight/Wall Wash
Hornet HP Round Lensed Downlight Remodeler Trimless:
Hornet HP Round Lensed Wall Wash Remodeler Trimless:
AB
8 1/16”
2 1/4”4”
3 5/16”Ø6 1/4”
Ceiling cut out: 4 1/2” dia.
Ceiling cut out: 4 1/2” dia.
Ø3 1/2”Ø3 9/16”
3 7 / 8
”3
1 / 8”
1/8”5/8”
Ø3 1/2”Ø3 9/16”
3 7 / 8
”3
1 / 8”
1/8”5/8”
Plaster Frame Installation Detail (for trimless fi xture only)
1. Refl ector Trim
2. Aperture plate
3. Ceiling ⅝”
4. Cast Aluminum Plaster Frame
5. Plaster Skim Coat (by others)
6. 6-32 Type F Thread Cutting Screw
431
265
Remodeler
STRUCTURE
5 1/2”Min. Clearance
RLD-REM-TL RLW-REM-TL
A 6 13/16” 7”B 12 15/16” 13 5/16”
Ø3 9/16”Ø3 1/2”
Ø2 7/16”
STRUCTURE
5 1/2”Min. Clearance
Ø3 9/16” Ø3 1/2”
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 8 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
23W LED, 3000K
Application Data:
D
W
L
FC
Candelas at Nadir
Deg Candela
0 875
5 866
15 797
25 653
35 455
45 271
75º Satin Ice Lens
LTL #631077
Lumens: 1,310
0o Aiming Angle
Horizontal
Footcandles
75
° S
ati
n Ic
e
Le
ns
D FC L W
5.0’ 36 5.1 5.1
7.5’ 16 7.7 7.7
10.0’ 9 10.3 10.3
12.5’ 6 13.5 13.5
Notes and Defi nitions:
Beam spread is to 50% center beam candlepower (CBCP).
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L=Eff ective Visual Beam length in feet (50% of maximum footcandle level).
W=Eff ective Visual Beam width in feet (50% of maximum footcandle level).
CB=Distance across or down to center beam location.
0
90
180
30
150
60
120
250
500
750
Candelas at Nadir
Deg Candela
0 4748
5 4478
15 2354
25 877
35 126
45 42
30º Solite Lens
LTL #1191156
Lumens: 1,645
0 15 30
45
60
75
90
1250
2500
3750
5000
Candelas at Nadir
Deg Candela
0 2236
5 2150
15 1624
25 1063
35 367
45 67
50º Solite Lens
LTL #1191155
Lumens: 1,513
0 15 30
45
60
75
90
500
1000
1500
2000
0o Aiming Angle
Horizontal
Footcandles
30
° S
oli
te
Le
ns
D FC L W
5.0’ 190 2.7 2.7
7.5’ 85 3.7 3.7
10.0’ 48 5.1 5.1
12.5’ 31 6.3 6.3
0o Aiming Angle
Horizontal
Footcandles
50
° S
oli
te
Le
ns
D FC L W
5.0’ 90 3.7 3.7
7.5’ 40 5.5 5.5
10.0’ 23 7.3 7.3
12.5’ 15 9.1 9.1
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website)
Hornet® HPRound Lensed Downlight/Wall Wash
Hornet HP Round Lensed Downlight:
Wattage: 16W 23W
Factor: 0.69 1.0
CCT: 2700K-83 3000K-83 3500K-83 4000K-83
Factor: 0.96 1.0 1.02 1.04
CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ 4000K-90+ CRISP 3CLA
Factor: 0.71 0.80 0.83 0.87 0.90 0.65 0.75
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 9 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
Wattage: 16W 23W
Factor: 0.69 1.0
MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website)
Application Data:
23W 3000K-83
Lumens: 1558
ZONAL LUMEN SUMMARY
Zone Lumens %Fixt
0-30 683 43.85
0-40 1005 64.53
0-60 1411 90.60
0-90 1558 100.00
40-90 553 35.47
60-90 146 9.40
90-180 0 0.00
0-180 1558 100.00
Luminaire Effi cacy: 68.9 Lm/W
LTL# 631078
0.5’ 48 50 50 50 48
1.5’ 94 99 100 99 91
2.5’ 88 94 95 94 88
3.5’ 60 66 68 66 61
4.5’ 40 44 46 45 41
5.5’ 28 31 32 31 29
6.5’ 21 23 23 23 21
7.5’ 16 17 18 17 16
0.5’ 37 40 37 40 37 40 36
1.5’ 72 77 75 78 74 77 72
2.5’ 69 73 74 75 74 73 69
3.5’ 48 52 54 54 54 52 49
4.5’ 33 36 37 38 37 36 33
5.5’ 23 26 27 27 27 26 24
6.5’ 17 19 20 20 20 19 18
7.5’ 14 15 16 16 16 15 14
0.5’ 21 23 22 23 23 22 22
1.5’ 48 51 51 52 51 51 48
2.5’ 56 59 61 61 61 60 56
3.5’ 47 51 52 53 53 51 47
4.5’ 36 39 41 41 41 39 36
5.5’ 27 29 31 31 31 29 27
6.5’ 21 22 24 24 24 23 21
7.5’ 16 18 19 19 19 18 16
1.5’
2’
2’
2’
2’
1.5’
Dis
tan
ce
fro
m c
eil
ing
Dis
tan
ce
fro
m c
eil
ing
Dis
tan
ce
fro
m c
eil
ing
Footcandles on Wall
1.5 Feet from Wall
1.5 Feet from Wall
2 Feet from Wall
Footcandles are average and rounded off .
Data for multiple units are based
on a minimum of fi ve units.
CCT: 2700K-83 3000K-83 3500K-83 4000K-83
Factor: 0.96 1.0 1.02 1.04
CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ 4000K-90+ CRISP 3CLA
Factor: 0.71 0.80 0.83 0.87 0.90 0.65 0.75
0
9090
180
300
150150
6060
120120
450
900
ACROSS45
ALONG
Hornet® HPRound Lensed Downlight/Wall Wash
Hornet HP Round Lensed Wall Wash:
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 10 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
DIMMING COMPATIBILITY:
Amerlux® Hornet fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general
compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration
(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.
TRIAC (Forward Phase) DIMMING (Standard)
Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. Best for retrofi t applications where TRIAC
dimmers are installed.
Notes:
• 120V or 277V*
• Dims down to less than 5% light output (most cases)
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
• Must meet dimmer Minimum Load Requirements per
dimming manufacturer
Lutron “Diva”
Lutron “Nova-T”
Lutron “Maestro”
Lutron “Vareo”
Lutron “Skylark”
Lutron “GP” Panel
Lutron Grafi k Eye QS
Compatible Dimmers
Wall Box (Incandescent Style, Wattage as required) Central System
TRIAC Wiring Diagram
ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard)
Utilizes specialized “ELV” dimmers. Best for New Construction applications
Notes:
• 120V or 277V*
• Dims down to less than 5% light output (most cases)
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
• Must meet dimmer Minimum Load Requirements
Lutron “Diva”
Lutron “Nova-T”
Lutron “Maestro”
Leviton “Surslide”
Lutron “Vareo”
Lutron “Skylark”
Leviton “Vizio”
Lutron “GP” Panel with PHPM-PA
Interface
Lutron Grafi k Eye QS with
PHPM-PA Interface
Compatible Dimmers
Wall Box (ELV Style) Central System
0-10V - DIMMING (-0-10V Option)
Integrates into a variety of building management and daylighting controls
Notes:
• 120V or 277V*
• Dims down to 1% light output
• Requires interface to turn off power to driver
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
Lutron “Diva” - DVTV with PP-
120H Interface
Leviton Renoir II 0-10v Lutron Grafi k Eye with
GRX-TVI Interface
Compatible Dimmers
Wall Box Central System
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
TRIACDimmingControl Neutral
ELV Wiring Diagram
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
ELVDimmingControl Neutral
0-10V Wiring Diagram
Gray
Purple
Black
White
Green
Driver
Line
Neutral
0-10VDimmingControl
Neutral
Red
Black
V+
V-
0-10V (-)
0-10V (+)
Ground
Ground
Ground
Ground
Ground
Ground
Switched Hot
Line
Line
Notes:
* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.
Please refer to 277V dimming installation instructions for 277V wiring diagrams.
--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---
Hornet® HPRound Lensed Downlight/Wall Wash
Passion. Power. Performance.
PROJECT: TYPE:
Ho
rne
t H
P R
LD
/RL
W
LIT-2007 • 03/16/18 • Page 11 of 11
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
DIMMING COMPATIBILITY:
Amerlux® Hornet fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general
compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration
(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.
LUTRON A-SERIES HI-LUME / ECOSYSTEM (-HILUME-A option)
Integrates into Lutron EcoSystem building management
Notes:
• 120V or 277V*
• Dims down to less than 5% light output
• May use 3-Wire or EcoSystem Control
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
3-Wire Wiring Diagram
EcoSystem Digital Control Wiring Diagram
Compatible Dimmers
Wall Box (3-Wire Fluorescent)
DIVA
Maestro
Nova T
Vareo
Central System
Lutron EcoSystem compatible controls
EMERGENCY DIMMING (-EM OPTION)
Wiring Diagram
Unswitched Hot
Common
Wall Switch
AC LEDDriver
LED Load LEDLED
OutputOutput
WhiteBlueBlack
ThermalProtector
WhiteBlack
WT/Red
WT/BLK
Blue
Yellow/BLK
Yellow
Violet
Brown
TestSwitch
ConverterConnector
2W-ITSEMERGENCY
LED
DRI
VER
Flex
A
Flex
B
Violet
Brown
White
Red
White Black
Purple Stripe
Purple
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
ECOSYS Bus
EcoSystemDimmingControl
Orange
E2
E1
Dimmed Hot
E1
E2
Ground
Purple Stripe
Purple
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
Cap unused ECOSYS wires
3-Wire Phase
DimmingControl
Orange Dimmed Hot
Ground Neutral
Neutral
Ground
E1
E2
(Cap off Orange wire)
Switched Hot
Switched Hot
DALI DIMMING (-DALI OPTION)
Digital control protocol allows individual fi xture control
Notes:
• 120V - 277V*
• Dims down to 1% light output in most cases
DALI Wiring Diagram
Compatible Dimmers
Wall Box (3-Wire Fluorescent)
Leviton CD250 Controller
Central System
Dynalite
Fifth Light
Purple
Purple/WT
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
DALI Bus
DALIDimmingControl
Ground
Neutral
Line
--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---
Notes:
* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.
Please refer to 277V dimming installation instructions for 277V wiring diagrams.
Hornet® HPRound Lensed Downlight/Wall Wash