  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    1/21

    cpg 20110318 1

    HOMER Online Training Course

    Participant Quick Steps Lesson 1: Simulation

    LESSON 1EXERCISE 1:SIMULATE A DIESEL-ONLY SYSTEM

    ADD LOAD AND GENERATOR TO SCHEMATIC

    1. Start HOMER and create a new file. Save it as lesson-1-exercise-1.hmr

    2. Click Add/Remove

    3. Check Primary Load 1 and Generator 1

    4. Click OK

    LOAD

    1. Click Primary Load 1

    2. For Label, type Small Load

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    2/21

    cpg 20110318 2

    3. Show Load type options

    4. Type first few values in table, then cut and paste from load profile.txt.

    5. Show annual data table

    6. Click Plot

    7. Show hourly data

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    3/21

    cpg 20110318 3

    8. Show Month and Day type lists

    9. Close DView and Load Inputs window.

    10. Save file

    GENERATOR COMPONENT

    1. Enter data for the generator component:

    Costs: 14, 13000, 13000, 0.5Sizes: 14 kWDescription: Generator; Abbreviation: Gen, Lifetime: 20000

    2. Show AC and DC options

    3. Click Fuel tab

    4. Click OK

    FUEL COST

    1. Click Diesel resource button

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    4/21

    cpg 20110318 4

    2. Specify the diesel fuel cost: 0.60

    3. Click OK

    SPECIFYECONOMICS INPUTS

    1. Show Other inputs

    2. Click Economics

    3. Change interest rate to 8

    CALCULATE

    1. Click Calculate

    2. Review results

    3. Click Small Load. Compare load profile to generator nominal power of 14 kW.

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    5/21

    cpg 20110318 5

    LESSON 1EXERCISE 2:SIMULATE DIESEL SYSTEMS WITH AND WITHOUT

    STORAGE1. Start HOMER and open the file lesson-1-exercise-1.hmr. Save the file as lesson-1-exercise-2.hmr.

    2. Click Add/Remove

    3. Add a battery to the schematic.

    4. Click OK.

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    6/21

    cpg 20110318 6

    5. Click Add/Remove

    6. Check Converter

    7. Choose Trojan L16P

    9. Enter data for the battery component:Costs: 1, 220, 220, 4

    Batteries per string: 8Sizes: 0, 1.

    10. Click Converter

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    7/21

    cpg 20110318 7

    11. Enter data for the converter component:

    Costs: 1, 800, 800, 0

    Sizes: 0, 12

    CALCULATE AND REVIEW RESULTS

    1. Click Calculate

    2. Double-click generator-only system

    3. Click Gen tab

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    8/21

    cpg 20110318 8

    4. Double-click generator-battery system.

    5. Click Gen tab

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    9/21

    cpg20110318 1

    HOMER Online Training Course

    Participant Quick Steps Lesson 2: Optimization

    LESSON 2EXERCISE 1:OPTIMIZE THE GENERATOR-BATTERY SYSTEM

    1. Open lesson-1-exercise-2.hmr and save it as lesson-2-exercise-1.hmr

    2. Expand the search space:Strings: add 2, 3Converters: add 4, 8

    3. Run the optimization and display overall results.

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    10/21

    cpg20110318 2

    4. Show categorized results.

    5. Note search space insufficient message

    6. Show winning sizes

    7. Adjust the search space: Add 4, 5, 6 strings

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    11/21

    cpg20110318 3

    8. Run the optimization and display overall results

    LESSON 2EXERCISE 2:ADD SOLAR PANELS1. Add PV to the schematic

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    12/21

    cpg20110318 4

    2. Specify PV costs

    7500, 7000,

    3. Specify sizes to consider0, 4, 8, 12

    4. Enter solar resource data36 N, 87 W, GMT -6

    5. Categorized results

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    13/21

    cpg20110318 5

    6. Simulation results for diesel-battery

    8. Simulation results for diesel-pv-battery

    8. Refine search space to add more sizes of PV array:2, 3, 5 kW

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    14/21

    cpg20110318 6

    9. Calculate and note renewable fraction of optimal system

    LESSON 2EXERCISE 3:ADD WIND TURBINES1. Add a wind turbine to the schematic

    2. Choose Generic 3 kW

    3. Costs: 1, 9000, 8000, 150

    4. Sizes to consider 0, 1, 2, 3, 4

    5. Hub height 20 m

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    15/21

    cpg20110318 7

    6. Note input warning

    7. Enter wind resource data: 6 m/s annual averaage

    8. Show hourly data

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    16/21

    cpg20110318 8

    9. Calculate

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    17/21

    cpg20110318 1

    HOMER Online Training CourseParticipant Quick Steps Lesson 3: Optimization

    LESSON 3EXERCISE 1:ONE-DIMENSIONAL SENSITIVTY ANALYSIS ON WIND

    SPEED

    1. Open lesson-2-exercise-3.hmr and save it as lesson-3-exercise-1.hmr

    2. Wind Resource Inputs

    3. Scaled annual average: 4 m/s

    4. Click Plot

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    18/21

    cpg20110318 2

    5. Wind Scaled Annual Average Sensitivity:4, 5, 6, 7

    6. Calculate

    7. Show Sensitivity results

    8. Double-click 7 m/s system

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    19/21

    cpg20110318 3

    LESSON 3EXERCISE 2:TWO-DIMENSIONAL SENSITIVITY ANALYSIS ON WIND

    SPEED AND FUEL PRICE1. Open lesson-2-exercise-3.hmr and save it as lesson-3-exercise-1.hmr

    2. Add fuel price sensitivity:0.8, 1.0

    3. Calculate4. Sensitivity table

    5. OST Graph

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    20/21

    cpg20110318 4

    6. Superimpose Generik 3 kW

    7. Click sensitivities button

  • 8/2/2019 HOMER Training - Participant Quick Step Guides

    21/21

    cpg20110318 5

    8. Calculate