holter dmo
TRANSCRIPT
![Page 1: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/1.jpg)
Holter Recording
![Page 2: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/2.jpg)
![Page 3: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/3.jpg)
Indications for AECG• Patients with unexplained syncope, near syncope or
episodic dizziness in whom the cause is not obvious
• Patients with unexplained recurrent palpitation
• To assess antiarrhythmic drug response
• Pacemaker and ICD function
• Patients with suspected variant angina
• Evaluation of possible or documented long QT
syndromes
![Page 4: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/4.jpg)
AECG equipmentIn 1957, Dr. Norman Holter introduces portable
devices to record the ECG
Current AECG equipment provides the detection and analysis of arrhythmias,ST-segment deviation, R-R intervals, QRS-T morphology
![Page 5: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/5.jpg)
Two categories of AECG recorders
• Continuous recorders
• Intermittent recorders
![Page 6: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/6.jpg)
AECG equipment…Continuous recorders• Used for 24 to 48 hours, which investigate
symptoms or ECG events that are likely to occur within that time frame
Intermittent recorders • Used for long periods of time (weeks to months)
to provide briefer, intermittent recordings to investigate events that occur infrequently
![Page 7: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/7.jpg)
Intermittent recorders…
External insertable loop recorder
Recording from external ILR
![Page 8: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/8.jpg)
Intermittent recorders Loop recorder• It should be worn continuously
• Particularly useful if symptoms are quite brief or if symptoms include only very brief incapacitation of the patient
• Family members can activate the recorder if the patient actually loses consciousness
• Newer loop recorders can be implanted under the
skin for long-term recordings
![Page 9: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/9.jpg)
Intermittent recorders…Event recorder• It should be attached by the patient and activated
after the onset of symptoms
• It is not useful for arrhythmias that cause serious symptoms such as loss of consciousness or near loss of consciousness because these devices take time to find, apply, and activate
• They are more useful for infrequent, less serious but sustained symptoms that are not incapacitating
![Page 10: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/10.jpg)
Continuous recorders
Conventional AECG recorders typically are small, lightweight devices
They contain a quartz digital clock and a separate recording track to keep time
A patient-activated event marker is conveniently placed on the device for the patient to indicate the presence of symptoms or to note an event
![Page 11: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/11.jpg)
Continuous recorders...
Limitations• Expense
• Limited storage capacity of digital data
![Page 12: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/12.jpg)
Continuous recorders...
Storage methodologies1.Flash memory card
2.Portable hard drive
![Page 13: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/13.jpg)
Continuous recorders...Flash cards• Very small, compact storage devices, size of a credit card
• Storage capacity --- 20 to 40MB
• Removed from the recording device once the recording is completed
• Inserted into a separate device where the data can be played back and analyzed
![Page 14: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/14.jpg)
Continuous recorders...
Portable hard drive• Utilize the same technology used in laptop computers
• Storage capacity --- >100MB
• It cannot be removed from the recorder
• Data to be downloaded to another storage device or
electronically transferred
![Page 15: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/15.jpg)
Methods of electrode preparation
The skin over the electrode area should be
• Shaved
• Gently abraded
• Cleansed with an alcohol swab
![Page 16: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/16.jpg)
Methods of analysisArrhythmia Analysis• Each beat is classified as normal,VPC,APC,paced,
others or unknown
• Summary data describing the frequency of atrial and ventricular arrhythmias are displayed typically in both tabular and graphical formats
![Page 17: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/17.jpg)
Methods of analysis…Conditions not suitable for interpretation
• LVH
• Preexcitation
• LBBB
• Marked baseline ST-segment distortion
![Page 18: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/18.jpg)
ASSESSMENT OF SYMPTOMS THAT MAY BERELATED TO DISTURBANCES OF HEART
RHYTHM
![Page 19: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/19.jpg)
Determination of the relation between patient’s transient symptoms to cardiac arrhythmias
Commonly caused by transient arrhythmias
1.Syncope
2.Near syncope
3.Dizziness
4. Palpitation
Less commonly caused by transient arrhythmias
1.Shortness of breath
2.Chest discomfort
3.Weakness
4.Diaphoresis
5.Transient ischemic attack
6.Vertigo
![Page 20: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/20.jpg)
After Myocardial Infarction
The 1-year risk of developing a malignant arrhythmia in an MI survivor after hospital discharge is 5% or less
The goal in risk-stratifying ---To identify at high risk patients Reduce arrhythmic events with an intervention
![Page 21: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/21.jpg)
After Myocardial Infarction…
The goal in risk-stratifying…
PVCs associated with a higher mortality
• Frequent PVCs (10 per hour)
• High-grade ventricular ectopy (repetitive PVCs, multi-form PVCs,VT)
![Page 22: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/22.jpg)
After Myocardial Infarction…
AECG is not needed in• Asymptomatic post-MI patients EF >
40% ---malignant arrhythmias are rare
![Page 23: Holter dmo](https://reader033.vdocuments.mx/reader033/viewer/2022061523/556db9f6d8b42aed2e8b49d6/html5/thumbnails/23.jpg)
Thank you