hiperstation messages and codes

298
Hiperstation Messages and Codes Hiperstation for VTAM Hiperstation for Mainframe Servers Hiperstation for WebSphere MQ Release 16.05

Upload: lynhan

Post on 02-Jan-2017

344 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Hiperstation Messages and Codes

HiperstationMessages and Codes

Hiperstation for VTAMHiperstation for Mainframe Servers

Hiperstation for WebSphere MQ

Release 16.05

Page 2: Hiperstation Messages and Codes

ii Hiperstation Messages and Codes

This docum

Copyright 1Copyright L

U.S. GOVERrestrictions 227.7202-1(FAR 52.227-

This producdisclosure, oCorporationconditions o

HiperstationFrontLine, a

CICSPlex, CWebSphere Corporation

Adobe® Readcountries.

All other co

Doc. JAN2017

December 28, 2

Please direct questions about Hiperstationor comments on this document to:

Compuware Customer Support

https://go.compuware.com/

ent and the product referenced in it are subject to the following legends:

994-2016 Compuware Corporation. All rights reserved. Unpublished rights reserved under the aws of the United States.

NMENT RIGHTS-Use, duplication, or disclosure by the U.S. Government is subject to as set forth in Compuware Corporation license agreement and as provided in DFARS a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT 1988), FAR 12.212(a) (1995), 19, or FAR 52.227-14 (ALT III), as applicable. Compuware Corporation.

t contains confidential information and trade secrets of Compuware Corporation. Use, r reproduction is prohibited without the prior express written permission of Compuware . Access is limited to authorized users. Use of this product is subject to the terms and f the user’s License Agreement with Compuware Corporation.

, Hiperstation, Hiperstation/Xchange, Hiperstation/Code Coverage, Abend-AID for CICS, nd Compuware are trademarks or registered trademarks of Compuware Corporation.

ICS Transaction Server, DB2, DFSMS, IBM, MQ Series, MVS, MVS/ESA, OS/390, VTAM, MQ, and z/OS are trademarks or registered trademarks of International Business Machines .

er® is a trademark of Adobe Systems Incorporated in the United States and/or other

mpany and product names are trademarks or registered trademarks of their respective owners.

016

Page 3: Hiperstation Messages and Codes

iii

Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiAccessing Hiperstation Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

HTML Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viiiUsing this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viiiAccessibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii

Installing Windows Accessibility Features . . . . . . . . . . . . . . . . . . . . . . . . . . ixSelecting Font and Font Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ixChanging Color and Contrast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ixSetting Cursor Blink Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ixUsing Keyboard Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ixAccessibility Exceptions Work Arounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . x

Known Exceptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xSolutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x

Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiFrontLine Support Web Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiContacting Customer Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi

Phone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiWeb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xiMail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xi

Corporate Web Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi

Chapter 1. Hiperstation User-Abend Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

Chapter 2. Hiperstation Messages: ARCHV through EHSC . . . . . . . . . . . . . . . . . . 2-1ARCHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1ATVCHKIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2ATVDBUTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3ATV-PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5ATV-PJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5ATV-PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8ATVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9ATV-RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-11ATV-RP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-12ATVRV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-13ATV-SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-13ATV-SR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-14ATVSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-15ATVTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-19CLOGGEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-24E62ALTMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-29E62CPFIL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-30E62DSINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-32E62EVALP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-32E62FILCL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-32E62PF5PI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-33E62PFMH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-33E62PRMFA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-34E62PRMFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-34E62PRUDT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-35E62WLOGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-35ECVSAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-35

Page 4: Hiperstation Messages and Codes

iv Hiperstation Messages and Codes

EHS3COPY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36EHSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39EHSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49

Chapter 3. Hiperstation Messages: EHSD through ETTERM . . . . . . . . . . . . . . . . . 3-1EHSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1EHSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6EHSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8EHSTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9EMALC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16EMCAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17EMFIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17EMGSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18EML62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18EMLO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28EMOB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29EMSCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29EMSRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29EMTCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29EMTRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30EMTRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30ET32LG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42ETGRCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44ETGRDA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44ETGREC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45ETGRFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46ETGRMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46ETGRPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48ETGRSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51ETGRST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51ETIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52ETPO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52ETPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54ETPRTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54ETRM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54ETRMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54ETRMFEIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-55ETRMGRPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56ETRMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56ETRMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56ETRMRACF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56ETRMRR1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56ETRMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-59ETRMVTAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-59ETTERM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-59

Chapter 4. Hiperstation Messages: HSPFE through RGSTRYGN . . . . . . . . . . . . . . 4-1HSPFE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1ICMSG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4MCSREPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15MQIO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19MQQMGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19MQROLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20MQSSEVNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20QFINS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21QQFDCI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21QQFHCI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31

Page 5: Hiperstation Messages and Codes

v

QQFHCIIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-31QQFHDATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-33QQFHPICM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-34QQFHPIHC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-35QQFHPIMQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-37QQFHPITP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-40QQFHPIUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-43QQFHPIVT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-44QQFVCONV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-47QQFVDATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-48RGSTRYGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-49

Chapter 5. Hiperstation Messages: SCRTCP through SYSPLEX . . . . . . . . . . . . . . 5-1SCRTCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1SCRWMQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-9SPBTCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-17SPCHG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-18SPCNTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-19SPCPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-32SPGMF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-32SPHPR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-35SPMSG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-38SPPARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-44SVABN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-45SVACF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-45SVATH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-45SVDEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-46SVMAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-46SVMANTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-52SVMAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-52SVMNANET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-53SVMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-53SVNET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-54SVNETC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-56SVNETCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-56SVNETREC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-57SVPEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-57SVRAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58SVSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58SVTSK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58SVUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58SVXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-58SYSPLEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-59

Chapter 6. Hiperstation Messages: TCPAR through VTCSUTIL . . . . . . . . . . . . . . . 6-1TCPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1TCPASYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3TCPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3TCPCNCTN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6TCPCNNLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6TCPIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7TCPMSSGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7TCPPBCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7TCPPBMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8TCPPBPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-10TCPPBRC1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-10TCPPBPRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-10

Page 6: Hiperstation Messages and Codes

vi Hiperstation Messages and Codes

TCPPBRPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12TCPPBST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22TCPPBUTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23TCPPROT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24TCPRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24TCPREVNT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26TCPRPLWK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29TCPRPTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-29TCPSCRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-31TCPSCSET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-34TCPSEVNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-34TCPSOCKT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37TCPSRPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-37TCPSRVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-39TCPSSL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-40VPCI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-40VPES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-41VTCSINTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-44VTCSMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-44VTCSREAD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46VTCSSRCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-46VTCSUTIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-50

Page 7: Hiperstation Messages and Codes

vii

Introduction Intro

Compuware is committed to providing user-friendly documentation in a variety of electronic formats. This section describes the available formats and how to access them, provides an overview of this manual and describes the conventions used within, and describes the resources available to help you.

Accessing Hiperstation DocumentationThe Hiperstation documentation is available on the Compuware Go (FrontLine) customer support website at http://go.compuware.com. Release Notes are provided in HTML format and manuals in Portable Document Format (PDF):

• Release Notes — Provides recent information for the Hiperstation product. In this file, you can quickly access system requirements, technical notes, customer support contact information, and a list of the new features available in the release. The Release Notes may be updated throughout the life cycle of a release with the most current version located on FrontLine for easy access to the latest product information.

• Hiperstation Installation and Configuration Guide — Provides installation and configuration procedures.

• Hiperstation for VTAM User Guide — Explains how to use Hiperstation for VTAM to test 3270 and LU0 applications.

• Hiperstation for WebSphere MQ User Guide— Explains how to use Hiperstation for WebSphere MQ to test WebSphere MQ applications.

• Hiperstation for Mainframe Servers User Guide — Explains how to use Hiperstation for Mainframe Servers to test APPC and TCP/IP applications.

• Hiperstation Auditor Guide — Explains how to use the Hiperstation Archive Function.

• Hiperstation Automated Testing Vehicle (ATV) Manager User Guide — Explains how to use the Hiperstation ATV Manager to manage your testing environment and test cases.

• Hiperstation Messages and Codes — Explains the messages and codes that Hiperstation produces.

• Hiperstation Scripting Reference — Introduces advanced script editing concepts and provides reference information for technical users.

• Hiperstation Reference Summary — Summarizes the commands used in Hiperstation for VTAM’s Domain Traveler and Session Demo features.

• Master Index — This file contains an indexed list of the contents of the entire manual set. To use this file, all of the book files and the master index file must be located in the same directory. Open the master index file and search for the desired term. Clicking on a search result will open the appropriate book at the desired page.

View and print PDF files with Adobe Reader. Download a free copy of the latest version of the reader from Adobe’s web site: http://www.adobe.com.

Note: With a few minor exceptions, PDF files comply with the requirements of section 508 of the Rehabilitation Act of 1973. Refer to the Accessibility preface in any of the user guides for information.

Page 8: Hiperstation Messages and Codes

viii Hiperstation Messages and Codes

For your convenience, Compuware also provides the Hiperstation manuals in the following formats:

• Hypertext Markup Language (HTML)

Access these formats on FrontLine, Compuware’s Customer Support Web site at http://frontline.compuware.com.

1. Log-in.

2. Select the desired product.

3. Click the Documentation link on the left selection bar.

4. Select the desired release. FrontLine presents a documentation index containing links to each of the product’s manuals in all of the available formats.

HTML FilesView HTML files with any standard Web browser. Simply click the HTML link on the selected FrontLine documentation page.

Note: As you review the HTML content, you may encounter the known issue regarding screens and other graphic figures in which the image may be cropped along the left or bottom edge.

Using this ManualThe manual explains all messages and codes that the Hiperstation products may present during operation and, if applicable, provides response instructions. The first chapter details user-abend codes. Subsequent chapters contain message information listed in alpha-numeric order and organized by prefix. Use the “Table of Contents” to help you find the message information you need.

AccessibilityIn accordance with section 508 of the Rehabilitation Act of 1973, Compuware has committed to making its products and services easier to use for everyone including people with disabilities.

Hiperstation is a mainframe application that runs on IBM’s OS/390 and z/OS operating systems. It has an ISPF interface that is accessed with IBM 327x-type terminals or with 3270 terminal emulator software. Since the mainframe environment offers few accessibility features, Compuware has focused its attention, with regard to accessibility, on 3270 terminal emulator software running on personal computers (PCs) with Microsoft Windows 2000 or more current. Hiperstation supports, with a few exceptions, Microsoft Windows accessibility features and Window-based Assistive Technology (AT) software and devices, such as Braille devices, screen readers, magnifiers, etc.

Note: Hiperstation is intended for use by mainframe software developers, programmers, and testers. Much of the input and output used or produced by Hiperstation, such as Job Control Language (JCL) and hexadecimal contents or dumps of memory, are not easily understood by the general public. Unfortunately, as in the case of hexadecimal dumps, data in these formats can be confusing to screen readers and therefore confusing to the people who use them. Effective use of this application requires the specialized knowledge of a mainframe systems software developer or programmer.

Hiperstation accessibility was evaluated using:

Page 9: Hiperstation Messages and Codes

Introduction ix

• Freedom Scientifics’ JAWS screen reader

• Attachmate Corporation’s myExtra Presentation Services tn3270 emulator

• Microsoft’s Windows accessibility features

• Adobe Reader using the “Read Out Loud” function

This evaluation not only identified accessibility exceptions, but revealed emulator and screen reader compatibility issues that in some cases can be remedied through appropriate configuration.

Installing Windows Accessibility FeaturesMicrosoft Windows operating systems offer several accessibility features to aid individuals who have difficulty typing or using a mouse, who are blind or have low vision, or who are deaf or are hard-of-hearing. Install these features during setup or later using the Windows installation disks. Refer to the “accessibility” topics in the Windows Help system for information on installing and using these features. Visit the Microsoft Web site, http://www.microsoft.com/enable, for additional information and tutorials.

Selecting Font and Font SizeMicrosoft Windows and emulator software packages offer font and font size settings to accommodate users with low vision. The emulator software’s tool bars and dialog boxes typically use the font specified in the operating system, while the terminal presentation uses the font and font size specified in the emulator. To change the font or font size:

• Presented on the toolbars and dialog boxes, refer to the Windows Help system.

• Presented in the terminal window, refer to the emulator’s documentation or Help.

Some screen readers recommend certain fonts and font sizes for compatibility. For example, Freedom Scientifics recommends setting the font to a common or “plain” font such as Lucida, Courier, or Times New Roman, and setting the font size to 10 points or smaller. Refer to the screen reader’s documentation or Help for these recommendations.

Changing Color and ContrastColor and contrast settings can assist users with low vision. ISPF and most emulator software packages offer color and contrast settings. If you are accessing Hiperstation with a terminal, use ISPF settings. Otherwise, adjust the color and contrast in the emulator software. Refer to ISPF Help or the emulator’s documentation or Help.

Setting Cursor Blink RateThe blink rate of the cursor can affect users with photosensitive epilepsy. Additionally, some screen readers require a specific blink rate. Some readers automatically adjust the blink rate while others expect you to adjust the rate. Refer to:

• The Microsoft Windows Help to find out how to set the cursor blink rate.

• The screen reader’s documentation or Help to find out the recommended blink rate.

Using Keyboard ShortcutsKeyboard access to application functions support users who cannot use a mouse.

Microsoft Windows provides keyboard access to all functions within the operating system, such as:

• Displaying or hiding the Windows Start Menu

• Showing the Desktop

Page 10: Hiperstation Messages and Codes

x Hiperstation Messages and Codes

• Minimizing all windows

• Searching for files

• Accessing the help system

• Controlling the behavior of the Windows accessibility features, for example, toggling the listening status to the microphone, or cycling focus backward and forward.

Most Windows-based applications also provide keyboard access to their functions. The combination of keys required to execute a given function is called a keyboard shortcut. Refer to the “Keyboard Shortcuts” topics in the Windows Help system for a complete list of Windows shortcuts. For a list of the shortcuts that are available in the emulator software or any third-party accessibility tool, such as the JAWS screen reader, refer to the software’s documentation or Help.

Accessibility Exceptions Work AroundsDuring Hiperstation accessibility evaluation, some exceptions were encountered where some accessibility features or AT were not fully supported. The causes of and solutions for these exceptions are currently under investigation by Compuware Corporation.

Known Exceptions

Accessibility exceptions include:

• Function Key (F Key) information at the bottom of the screen is not read by the screen reader on some screens. This is believed to be caused by an external interface. See “Solutions” for a viable work-around.

• Some system error and warning messages are not read by the screen reader when issued. Believed to be caused by an external interface. See “Solutions” for a viable work-around.

• Some pop-up dialog boxes or windows do not capture exclusive focus and are not read correctly by the screen reader. This is believed to be caused by an external interface. No known solution is currently available.

• System error and warning messages do not capture visual focus for the screen magnifier. This is believed to be caused by an external interface. No known solution is currently available.

• Some entry and display fields lack individual labels. When entry fields are accessed using the Tab key, the entire individual line is read.

• Current Web-based reports are not easily navigated using the keyboard and lack table element coordinate tags. Additionally, some of these reports contain color-coded elements — for example, the color of some elements conveys meaning.

Solutions

When the screen reader fails to read the F Key information upon entry to a new screen, do one of the following:

• Use the arrow keys to move the cursor down to the lines with the F Key information. The screen reader reads each line as the cursor is placed on it.

• Press the Page Up key for the screen reader to reread the entire screen.

When the screen reader fails to read an error or warning message, an audio alert occurs if this feature is enabled on your system. Press the Up key to place the cursor on the line containing the error message, usually on the top or title line. The screen reader reads the line and its error message individually.

Page 11: Hiperstation Messages and Codes

Introduction xi

Getting Help Compuware provides a variety of support resources to make it easy for you to find the information you need.

FrontLine Support Web SiteYou can access online information for Compuware products via our FrontLine support site at http://frontline.compuware.com.

FrontLine provides access to critical information about your Compuware products. You can review frequently asked questions, read or download documentation, access product fixes, or e-mail your questions or comments. The first time you access FrontLine, you are required to register and obtain a password. Registration is free.

Compuware now offers User Communities, online forums to collaborate, network, and exchange best practices with other Compuware solution users worldwide. Go to http://groups.compuware.com to join.

Contacting Customer SupportIf you have difficulty with Hiperstation, refer to the information in the appropriate user’s guide for help or consult with the Hiperstation technical representative at your site. If the problem persists, please obtain the following information before calling Compuware:

1. The release number of the product being used

2. The release number of the transaction processing utility (such as CICS, IMS/DC, or ISPF) being used

3. The operating system being used to help determine operating system dependencies

4. If an abend occurs, note the displacement and the module in which it occurs, and if possible, obtain a copy of the system dump.

5. The sequence of issued transactions and/or commands that resulted in the problem and the data type involved.

Phone• USA and Canada: 1-800-538-7822 or 1-313-227-5444.• All other countries: Contact your local Compuware office. Contact information is

available at http://frontline.compuware.com.

Web

You can report issues via the Report and Track Calls tab on the FrontLine home page.

Note: Please report all high-priority issues by phone.

MailHiperstation Customer SupportCompuware CorporationOne Campus MartiusDetroit, MI 48226-5099

Corporate Web SiteTo access Compuware’s site on the Web, go to http://www.compuware.com.

The Compuware site provides a variety of product and support information.

Page 12: Hiperstation Messages and Codes

xii Hiperstation Messages and Codes

Page 13: Hiperstation Messages and Codes

1-1

Chapter 1.

1Hiperstation User-Abend Codes Chap 1

The following table lists all Hiperstation mainframe user abend codes in decimal and hexadecimal. It explains each code and the appropriate action to take for resolution.

Table 1-1. Hiperstation User-Abend Codes

Dec Hex Explanation User Response

200 C8 Unknown VTAM request was made to the Hiperstation SCIP exit.

If the error persists, contact Compuware Customer Support for assistance.

123 7B Hiperstation cannot support your z/OS release. Refer to the Hiperstation Release Notes for supported releases of z/OS. If you have recently installed a new version of z/OS, contact Compuware Customer Support for assistance.

100 64 During program execution, the corruption of a program save area was detected.

Contact Compuware Customer Support for assistance.

345 159 An unexpected error occurred while processing the attributes of a dataset.

If the error persists, contact Compuware Customer Support for assistance.

769 301 During program execution, a stack underflow condition was detected, or an internal subroutine was not entered properly.

Contact Compuware Customer Support for assistance.

770 302 During program execution, a stack overflow condition was detected or an internal subroutine was not exited properly.

If the error persists, contact Compuware Customer Support for assistance.

777 309 The release of a user-generated default parameter table does not agree with the current Hiperstation release.

You must apply the values of the previous default table to the current version of Hiperstation. Do not copy the old table — it must be regenerated. Also, ensure that the correct table is being used. If you have further problems, contact Compuware Customer Support for assistance.

817 331 Hiperstation has detected a problem based on your module and its displacement.

Contact Compuware Customer Support for assistance.

1009 3F1 This is an unexpected return code from the VTAM CHECK macro. The VTAM subsystem may have terminated unexpectedly.

If the VTAM subsystem was still active at the time of the abend, report the problem to Compuware Customer Support. If the VTAM subsystem was not active, repeat the test while it is active.

4094 FFE An unknown VTAM request was made to the Hiperstation SYNAD exit. This may be caused by the VTAM subsystem terminating unexpectedly.

If the VTAM subsystem was still active at the time of the abend, report the problem to Compuware Customer Support. If the VTAM subsystem was not active, repeat the test while it is active.

Page 14: Hiperstation Messages and Codes

1-2 Hiperstation Messages and Codes

Page 15: Hiperstation Messages and Codes

2-1

Chapter 2.

2Hiperstation Messages: ARCHV through EHSC Chap 2

The chapter explains messages with the prefix ARCHV through the prefix EHSC and, if applicable, provides response actions you can take to resolve the issue causing the message. Messages are listed in alpha-numeric order and grouped by prefix. Use the “Contents” to find the message information you need.

ARCHVARCHV000 INVALID DATASET NAME

Explanation: The repository registry dataset must be 1 - 35 characters in length, including the prefix.

ARCHV001 NAME IS NOT UNIQUE

Explanation: The name specified for the archive record request is already being used.

ARCHV002 INVALID CHARACTER

Explanation: Description cannot contain the following characters: ` ~ [ $ % _ + } ! ¦

ARCHV003 DATASET CONFLICT

Explanation: Datasets exist that match <repository_registry_dsn>.#*

ARCHV004 ALREADY EXITS

Explanation: A dataset already exists with the dataset name specified on the repository registry dataset.

ARCHV005 NOT UNIQUE

Explanation: This request would create repository datasets (based off registry name) that would conflict with datasets created by an existing Global or Archive Record Request.

ARCHV006 ARCHIVE CONFLICT

Explanation: The repository dataset specified conflicts with repositories created by an Archive Record Request (which must be unique).

ARCHV007 NO MORE SEGMENTS

Explanation: Cannot restart this archive request because all repository dataset segments have been used.

System Action: All segments have been used so this archive request cannot be restarted.

User Response: Create a new archive request using another dataset name.

ARCHV008 CONTROL ERROR

Explanation: Unable to read control record for this archive repository set.

ARCHV009 DATASET CONFLICT

Explanation: Archive request cannot restart since datasets exist that match our repository dataset specification. The repository dataset specification is the <registry name>.#*

ARCHV010 DELETE FAILURE

Explanation: IDCAMS request to delete the existing dataset failed.

Page 16: Hiperstation Messages and Codes

2-2 Hiperstation Messages and Codes

ARCHV011 ENTER 1 OR 2. THE ONLY VALID OPTIONS ARE 1 (DELETE) OR 2 (TERMINATE) AND YOU MUST SPECIFY ONE OF THESE TO CONTINUE.

Explanation: This occurs when the user enters an invalid option or no option and presses the Enter key on the Delete or Terminate pop-up window.

ATVCHKINATVCHKIN-0358W Script <script_name> in Dataset <dsn> not available.

Explanation: The desired script could not be located in the supplied script dataset referenced by the SQQFBASE or SQQFDUB DD names. These DD names are set by the ATV.

System Action: The named script is ignored for remediation purposes.

User Response: Determine whether the named script should be involved in the remediation process i.e. are both the base and dubbed scripts available for remediation comparison. If the script is an ATV-supplied signon or signoff script then it should not be involved in remediation.

ATVCHKIN-0359E Comparison Log <dataset_name> not available.

Explanation: The named comparison log containing the results of an ATV test case execution was not available for processing via the SQQFCLOG DD name. The SQQFCLOG DD name is set by the ATV.

System Action: Remediation processing terminates.

User Response: Determine whether the named comparison log dataset is allocated and/or why the named dataset cannot be opened.

ATVCHKIN-0360E Mismatch Log <dataset_name> not available.

Explanation: The named sequential log designated to contain the mismatches found by the remediation process cannot be opened. The mismatch log is attached to the SQQFMISL DD name, which is set by the ATV.

System Action: Remediation processing terminates.

User Response: Determine whether the named mismatch log dataset is allocated and/or why the named dataset cannot be opened.

ATVCHKIN-0361E Storage could not be allocated for <area_name>.

Explanation: Working storage could not be obtained for the control block named in the message.

System Action: Remediation processing terminates.

User Response: Allocate additional storage to the remediation job, via the REGION parameter.

ATVCHKIN-0362E Creation of the Global Hash Table failed.

Explanation: The C hcreate() function used to establish the Global Hash Table failed.

System Action: Remediation processing terminates.

User Response: Allocate additional storage to the remediation job, via the REGION parameter. If this fails to correct the problem contact Compuware Customer Support.

ATVCHKIN-0363E Dynalloc of Script dataset failed, DSN: <dataset_name> - code=<rc>, info code=<info_code>

Explanation: The C dynalloc() function could not allocate a script in the named script dataset.

System Action: Scripts in the named dataset are ignored for remediation purposes.

User Response: Use the returned code (__errcode) and information code (__infocode) to identify the dataset allocation problem.

Page 17: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-3

ATVCHKIN-0364E fwrite() wrote a partial record, <nn> of <mm> characters.

Explanation: The C fwrite() function failed to write a complete logical record to the mismatch log, writing only <nn> of <mm> bytes in the record.

System Action: Data not written by the partial fwrite() is lost.

User Response: Determine why data cannot be written to the SQQFMISL mismatch log file. If the problem persists contact Compuware Customer Support.

ATVDBUTLATVDBUTL-0001W Processing <db_request> request failed, rc = .

Explanation: Database server encountered an error processing a <db_request> request. The database server issued a return code of rc.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information.

ATVDBUTL-0002E Dynalloc of ATV Database file failed, DSN(<datasetname>) return code= <rc>, info code=<ic>

Explanation: Database server encountered an error allocating the dataset <datasetname>. The operating system replied with return code of rc and an information code of ic.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information. Refer to the IBM publication z/OS MVS Programming: Authorized Assembler Services Guide for more information on the return code of rc and an information code of ic.

ATVDBUTL-0003E Open of file (<datasetname>) failed, return code = rc

Explanation: Database server encountered an error opening the dataset <datasetname>. The operating system replied with return code of rc.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information. Refer to the IBM publication z/OS MVS Programming: Authorized Assembler Services Guide for more information on the return code of rc and an information code of ic.

ATVDBUTL-0004E ATV Database name not found in request

Explanation: An invalid request was sent to the ATV database server program.

System Action: Database request is terminated.

User Response: Internal product error. Contact Compuware Customer Support.

ATVDBUTL-0005W Read error (<datasetname>)

Explanation: The ATV database server program received an error condition when reading the ATV Database.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information.

ATVDBUTL-0006E Record not found

Explanation: The ATV database server program could not find an expected record on the ATV Database. The ATV database could be corrupted.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information. Contact Compuware Customer Support if unable to resolve.

ATVDBUTL-0007I Record not found

Explanation: The ATV database server program received a not found condition while reading the ATV Database. This can be a normal condition.

Page 18: Hiperstation Messages and Codes

2-4 Hiperstation Messages and Codes

System Action: Processing continues.

User Response: None.

ATVDBUTL-0008E Unable to allocate storage for <datastructure>, cannot continue.

Explanation: The ATV database server program was unable to allocate required memory.

Explanation: Database request is terminated.

System Action: Run this request with a larger region size.

ATVDBUTL-0009E DB request (<db_request>) missing required tags.

Explanation: An invalid request was sent to the ATV database server program.

System Action: Database request is terminated.

User Response: Internal product error. Contact Compuware Customer Support.

ATVDBUTL-0010E Invalid length (<length>) for tag <tag>

Explanation: An invalid request was sent to the ATV database server program.

System Action: Database request is terminated.

User Response: Internal product error. Contact Compuware Customer Support.

ATVDBUTL-0011W Duplicate record found

Explanation: An invalid request was sent to the ATV database server program.

System Action: Database request is terminated.

User Response: Retry request. If unable to resolve, contact Compuware Customer Support.

ATVDBUTL-0012I Error opening file (<dsn>)

Explanation: The ATV database server program was unable to open the script <dsn> to import the requested script into the vehicle.

System Action: Database request is terminated.

User Response: Ensure you are selecting a valid Hiperstation script. If unable to resolve, contact Compuware Customer Support.

ATVDBUTL-0020I Unexpected tag (<tag>) encountered processing (<request>)

Explanation: An invalid request was sent to the ATV database server program.

System Action: Database request is terminated.

User Response: Retry request. If unable to resolve, contact Compuware Customer Support.

ATVDBUTL-0021E Test case save failed.

Explanation: The ATV database server program encountered an error saving the current test case.

System Action: Database request is terminated.

User Response: Retry request. If unable to resolve, contact Compuware Customer Support.

ATVDBUTL-0024E Dynalloc failed with error code = rc, info code DSN: <datasetname>

Explanation: Database server encountered an error allocating the dataset <datasetname>. The operating system replied with return code of rc.

System Action: Database request is terminated.

User Response: See adjacent error messages for more information. Refer to the IBM publication z/OS MVS Programming: Authorized Assembler Services Guide for more information on the return code of rc.

ATVDBUTL-0025I Deallocate failed, error code = rc, info code = ic, DSN: <datasetname>

Explanation: Database server encountered an error deallocating the dataset <datasetname>. The operating system replied with return code of rc and an information code of ic.

Page 19: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-5

System Action: Database request is terminated.

User Response: See adjacent error messages for more information. Refer to the IBM publication z/OS MVS Programming: Authorized Assembler Services Guide for more information on the return code and information code.

ATV-PCATV-PC105I Processing For Strobe Performance Complete.

Explanation: Informational.

User Response: None.

ATV-PC106I Strobe report written to dataset_name.

Explanation: Informational.

User Response: None.

ATV-PC107I ATV Performance Execution Completed.

Explanation: Informational.

User Response: None.

ATV-PC117E ATV Performance Measurement Not Found. Return Code is rc.

Explanation: The attempted STOP of the Strobe Measurement failed because the specified Measurement Number was not located.

User Response: Use the Measurement number specified in the Performance Vehicle JESLOG with message ATV-SM104I to check the status of the Measurement in Strobe.

ATV-PC118E ATV Performance Report Creation Return Code exceeded allowable value. RC = rc.

Explanation: The Strobe Measurement Add command returned an unacceptable Return Code.

User Response: Look up the Return Code to determine the failure cause in the Strobe Manual.

ATV-PC119E ATV Performance Measurement Not Found. Return Code is rc.

Explanation: The attempted STOP of the Strobe Measurement failed because the specified Measurement Number was not located.

User Response: Use the Measurement number specified in the Performance Vehicle JESLOG with message ATV-SM104I to check the status of the Measurement in Strobe.

ATV-PC120E ATV Sample Dataset Allocation Error. Message is allocation_error.

Explanation: The Sample Dataset allocation attempted by Strobe failed.

User Response: Use the error message to identify why the allocation attempt by Strobe failed.

ATV-PJATV-PJ101E Jeslog/JCL Report Allocation Failed, RC = nn

Explanation: The attempted allocation for the JESLOG Report dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PJ101I Processing Jeslog Dataset dataset_name.

Explanation: Informational.

User Response: None.

Page 20: Hiperstation Messages and Codes

2-6 Hiperstation Messages and Codes

ATV-PJ101W The Passed Report dataset_name is not a JESLOG Report. Skipping JESLOG Processing.

Explanation: The report passed for JESLOG processing is not an actual JESLOG. The JESLOG Report Processing function is being bypassed.

User Response: Verify that the passed dataset, dataset_name, is actually a JESLOG. If it is, contact Compuware Customer Support for assistance. Be prepared to submit the JESLOG in question for examination.

ATV-PJ102E The Specified Dataset dataset_name is not catalogued

Explanation: The JESLOG/JCL dataset, dataset_name, was not found on the MVS catalogue.

User Response: Verify that the dataset referenced, dataset_name, exists. If it does, contact Customer Support.

ATV-PJ102I Processing Service Unit Record.

Explanation: Informational.

User Response: None.

ATV-PJ102W Service Units were not found in Jeslog dataset_name. Setting Service Units to 999999.

Explanation: The Service Unit value was not found in the JESLOG dataset_name. The JESLOG Report Process will use the value 999999 instead.

User Response: Verify that the passed dataset, dataset_name, is a JESLOG that does not contain the Service Units value.

ATV-PJ103I Processing CPU Usage Record.

Explanation: Informational.

User Response: None.

ATV-PJ103W Baseline Jeslog Report Recall Failed, RC = nn.

Explanation: The System recall for the Baseline JESLOG Performance Report failed.

User Response: Verify that the Baseline JESLOG report exists, was on non-DASD storage, and was available for SMS recall processing.

ATV-PJ104E Unknown Error Occurred While Checking Dataset dataset_name. RC = nn Reason Code = nnnn

Explanation: An unknown error was encountered when validating the dataset_name.

User Response: Use the Return Code and Reason Code to identify the error and correct it.

ATV-PJ104I Writing Performance Vehicle Jeslog Validation Report.

Explanation: Informational.

User Response: None.

ATV-PJ104W Using Baseline Values from the Test Case Record.

Explanation: Related to message ATV-PJ103W and ATV-PJ105W. The JESLOG Report Process will use the values from the Test Case record to validate JESLOG pass/fail status.

User Response: If the Baseline JESLOG Performance Report exists, was on non-DASD storage, was available for SMS recall processing, and the Baseline values in the Test Case Record are not sufficient, contact Compuware Customer Support.

ATV-PJ105E Allocation Error for Dataset dataset_name. RC = nn.

Explanation: The attempted allocation for the JESLOG dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PJ105I Processing For Jeslog Report dataset_name Complete.

Explanation: Informational.

Page 21: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-7

User Response: None.

ATV-PJ105W Baseline Jeslog Report Does Not Exist.

Explanation: The Test Case Record specifies the use of a Baseline JESLOG Performance Report when determining JESLOG pass/fail status and the Baseline Report could not be located in the MVS Catalogue.

User Response: Verify that the Baseline JESLOG Performance Report exists for the Test Case in question. If it does, contact Compuware Customer Support.

ATV-PJ106E Read Error for Dataset dataset_name. RC = nn.

Explanation: The attempted read for the JESLOG dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PJ107E Jeslog Dataset dataset_name does not contain all of the necessary information to create the Jeslog Performance Vehicle Report. Halting Jeslog Processing.

Explanation: The JESLOG dataset did not contain the Service Unit value.

User Response: Verify that the passed dataset, dataset_name, is a JESLOG that does not contain the Service Units value. If it does, contact Compuware Customer Support for assistance. Be prepared to submit the JESLOG in question for examination

ATV-PJ107I Jeslog Report Validation Complete.

Explanation: Informational.

User Response: None.

ATV-PJ108E Jeslog Dataset dataset_name does not contain all of the necessary information to create the Jeslog Performance Vehicle Report. Halting Jeslog Processing.

Explanation: The JESLOG dataset did not contain the CPU value.

User Response: Verify that the passed dataset, dataset_name, is a JESLOG that does not contain the CPU value. If it does, contact Compuware Customer Support for assistance. Be prepared to submit the JESLOG in question for examination

ATV-PJ108I Baseline Jeslog Report is Being Recalled from non-DASD Storage.

Explanation: Informational.

User Response: None.

ATV-PJ109E Jeslog Dataset dataset_name does not contain all of the necessary information to create the Jeslog Performance Vehicle Report. Halting Jeslog Processing.

Explanation: The JESLOG dataset did not contain the SRB value.

User Response: Verify that the passed dataset, dataset_name, is a JESLOG that does not contain the SRB value. If it does, contact Compuware Customer Support for assistance. Be prepared to submit the JESLOG in question for examination

ATV-PJ118E Jeslog/JCL Report Validation Ended with Errors. Return Code = nn

Explanation: There was an error during JESLOG/JCL validation execution.

User Response: Use the Return Code to identify the error and correct if possible. Contact Customer Support with the Return Code and be prepared to submit the JESLOG and or JCL Output for examination, if needed.

ATV-PJ119E Write Error to Dataset dataset_name Return Code = nn.

Explanation: The attempted write to the JESLOG/JCL Report dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

Page 22: Hiperstation Messages and Codes

2-8 Hiperstation Messages and Codes

ATV-PSATV-PS101E Summary Report Allocation Failed. RC = rc.

Explanation: The attempted allocation of the Summary dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PS101I Processing Summary Dataset dataset_name.

Explanation: Informational.

User Response: None.

ATV-PS102E The Specified Dataset dataset_name is not Cataloged.

Explanation: The Summary dataset, dataset_name, was not found on the MVS catalogue.

User Response: Verify that the dataset referenced, dataset_name, exists. If it does, contact Compuware Customer Support

ATV-PS102I Baseline Summary Report is Being Recalled from non-DASD Storage.

Explanation: Informational.

User Response: None.

ATV-PS102W Baseline Summary Report Does Not Exist.

Explanation: The Test Case Record specifies the use of a Baseline Summary Performance Report when determining Summary pass/fail status and a Baseline Report could not be located in the MVS Catalogue.

User Response: Verify that the Baseline Summary Performance Report exists for the Test Case in question. If it does, contact Compuware Customer Support.

ATV-PS103E The Specified Dataset dataset_name is an Unsupported VSAM File.

Explanation: The Summary dataset, dataset_name, is a VSAM file.

User Response: Verify that the dataset referenced, dataset_name, is a VSAM file. If it is not, contact Compuware Customer Support

ATV-PS103W Using Baseline Values from the Test Case Record.

Explanation: Related to message ATV-PS102W and ATV-PS104W. The Summary Report Process will use the values from the Test Case record to validate the Summary pass/fail status.

User Response: If the Baseline Summary Performance Report exists, was on non-DASD storage, was available for SMS recall processing, and the Baseline values in the Test Case Record are not sufficient, contact Compuware Customer Support.

ATV-PS104E Unknown Error Occurred While Checking Dataset dataset_name. RC = rc Reason Code = nn

Explanation: An unknown error was encountered when validating dataset_name.

User Response: Use the Return Code and Reason Code to identify the error and correct it.

ATV-PS104I Writing Performance Vehicle Summary Validation Report.

Explanation: Informational.

User Response: None.

ATV-PS104W Baseline Summary Report Recall Failed, RC = rc.

Explanation: The System recall for the Baseline Summary Performance Report failed.

User Response: Verify that the Baseline Summary report exists, was on non-DASD storage, and was available for SMS recall processing.

ATV-PS105E Allocation Error for Dataset dataset_name. RC = rc.

Explanation: The attempted allocation for the Summary dataset failed.

Page 23: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-9

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PS105I Processing For Summary Report dataset_name Complete.

Explanation: Informational.

User Response: None.

ATV-PS106E Read Error for Dataset dataset_name. RC = rc.

Explanation: The attempted read of the Summary dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PS106I The Total Number of Members Processed is: nn

Explanation: Informational.

User Response: None.

ATV-PS107E Summary Dataset dataset_name does not contain all of the necessary information to create the Summary Performance Vehicle Report. Halting Summary Processing.

Explanation: Informational

User Response: None.

ATV-PS107I Summary Report Validation Complete.

Explanation: Informational.

User Response: None.

ATV-PS108E Summary Dataset dataset_name does not contain all of the necessary information to create the Summary Performance Vehicle Report. Halting Summary Processing.

Explanation: Informational

User Response: None.

ATV-PS109E Write Error to Dataset dataset_name. Return Code = rc.

Explanation: The attempted write to the Summary Performance Report dataset failed.

User Response: Use the supplied Return Code to identify the cause of the failure and correct the cause.

ATV-PS110E Summary Report Validation Ended with Errors. Return Code = rc.

Explanation: There was an error during Summary validation execution.

User Response: Use the Return Code to identify the error and correct if possible. Contact Compuware Customer Support with the Return Code and be prepared to submit the JESLOG for examination, if needed.

ATV-PS111E The Passed Report dataset_name is not a Summary Report. Skipping Summary Processing.

Explanation: The report passed for Summary processing is not an actual Summary. The Summary Report Processing function is being bypassed.

User Response: Verify that the passed dataset, dataset_name, is actually a Summary Report from Hiperstation's Unattended Batch Playback Process. If it is, contact Compuware Customer Support for assistance. Be prepared to submit the Summary Report in question for examination

ATVRATVR0200 Invalid dataset: <dataset_name>

Explanation: Dataset information for the mismatch log passed into remediation by the ATV could not be determined.

Page 24: Hiperstation Messages and Codes

2-10 Hiperstation Messages and Codes

System Action: Remediation processing terminates.

User Response: Contact Compuware Customer Support.

ATVR0201 Invalid dataset: <dataset_name>

Explanation: The mismatch log passed into remediation by the ATV was not a sequential dataset/member.

System Action: Remediation processing terminates.

User Response: Contact Compuware Customer Support.

ATVR0202 Allocation of <dataset_name> failed.

Explanation: The named mismatch log could not be allocated for use.

System Action: Remediation processing terminates.

User Response: Determine why the named dataset could not be allocated. If the problem persists, contact Compuware Customer Support.

ATVR0203 Mismatch file <dataset_name> is empty.

Explanation: No mismatches were discovered during the remediation processing for the execution of this ATV test case.

System Action: Remediation processing terminates.

User Response: None.

ATVR0204 Invalid Base(<linelength1>) or Dubbed(<linelength2>) Line Lengths

Explanation: The line lengths supplied to this routine were non-numeric.

System Action: Remediation processing terminates.

User Response: Contact Compuware Customer Support.

ATVR0205 Dubbed script: <script_dsn> Member: <member_name> returned <status_text> on existence test.

Explanation: The dubbed or actual script named could not be located, so mismatched remediation is not possible.

System Action: Remediation processing terminates.

User Response: Determine why the named script member is not in the named dub script dataset.

ATVR0206 Base script: <script_dsn> Member: <member_name> returned <status_text> on existence test.

Explanation: The base or expected script named could not be located, so mismatched remediation is not possible.

System Action: Remediation processing terminates.

User Response: Determine why the named script member is not in the named base script dataset.

ATVR0207 Allocation of base script: <script_dsn_&_member> failed.

Explanation: The base or expected script to which remediation would be applied cannot be allocated.

System Action: Remediation processing terminates.

User Response: Determine why the named script member cannot be allocated.

ATVR0208 Severe in TBDISPL Service: <RC>

Explanation: The ISPF function used to display the remediation mismatch panel has failed.

System Action: Remediation processing terminates.

User Response: Use the return code to determine why the display failed.

Page 25: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-11

ATVR0209 Script: <dataset_name> returned <RC>

Explanation: The REXX SYSDSN() function failed for the named dataset.

System Action: Remediation processing terminates.

User Response: Use the return code to determine why the sysdsn() function failed.

ATVR0210 <TSO_Service> RETURN CODE(<RC>)

Explanation: The named TSO function executed with the displayed return code.

System Action: Information only.

User Response: None.

ATVR0211 <ISPF_Service> rc(<RC>)

Explanation: The named ISPF function executed with the displayed return code.

System Action: Information only.

User Response: None.

ATV-RCATV-RC101E Input Dataset Allocation Error.

Explanation: The Input file used for domain control could not be allocated.

User Response: Inspect the Supervisor Job Log for related messages and correct the cause of the allocation error.

ATV-RC101I CICS Region Stop Command Issued Successfully.

Explanation: Informational

User Response: None.

ATV-RC101W Dataset FREE Command Not Accepted.

Explanation: The command to free the dataset used for domain control was rejected.

User Response: None.

ATV-RC102E JESLOG Processing Unavailable.

Explanation: Related to messages ATV-RC101E, ATV-RC103E, ATV-RC104E, and ATV-RC105E. Because of one of these previous errors, JESLOG Performance Report Processing will not be available.

User Response: Inspect the Supervisor Job Log for messages related to ATV-RC101E, ATV-RC013E, ATV-RC104E, and ATV-RC105E to identify and correct the cause of the original error.

ATV-RC102I Region domain_name Shutdown Processing Complete.

Explanation: Informational

User Response: None.

ATV-RC102W JESLOG Validation May Not Be Available.

Explanation: Related to message ATV-RC101W. As a result of this message, JESLOG Performance Report Processing may not be available, but report processing will still be attempted.

User Response: Inspect the Supervisor Job Log for other messages if the JESLOG Performance Report Processing does not succeed.

ATV-RC103E Output Dataset Allocation Error.

Explanation: The Output file used for domain control could not be allocated.

User Response: Inspect the Supervisor Job Log for related messages and correct the cause of the allocation error.

Page 26: Hiperstation Messages and Codes

2-12 Hiperstation Messages and Codes

ATV-RC104E Region Stop Command Not Accepted.

Explanation: The STOP command was not accepted for the domain in this test case.

User Response: Inspect the Supervisor Job Log for related messages and correct the cause of the command refusal.

ATV-RC105E Region domain_name is not currently active.

Explanation: The domain listed was not found to be active on the system at the time of domain shutdown processing.

User Response: Inspect the System Log for related messages to identify the cause of the specified domain to be inactive. If it is active, contact Compuware Customer Support.

ATV-RC106E Security Package Refused the Shutdown Request.

Explanation: Your system's security package (RACF, ACF2, TopSecret, etc.) refused the request to shutdown the domain in use.

User Response: The most likely cause is the user's lack of security authority to the MVS modify command. This is needed for domain control within the test execution. See message ATV-RC107E for additional information.

ATV-RC107E See dataset dataset_name for details.

Explanation: Related to messages ATV-RC106E, ATV-RC108E, and ATV-RC109E. The dataset named contains the portion of the system log used for processing.

User Response: Inspect the specified dataset for additional messages relating the specific error and correct where possible. If no additional errors are located, contact Compuware Customer Support and be prepared to submit the specified dataset for examination.

ATV-RC108E Region domain_name is already Shutdown.

Explanation: The identified domain has already been shutdown and isn't currently active.

User Response: See message ATV-RC107E for the portion of the system log used for processing and inspect it for additional messages relating to this one.

ATV-RC109E An Unknown Error occurred during the Shutdown request.

Explanation: An unknown error was encountered during domain shutdown request processing.

User Response: See message ATV-RC107E for the portion of the system log used for processing and inspect it for additional messages relating to this one.

ATV-RPATV-RP101I ATV Jeslog Report Unavailable for Target Region in test case test_case_name at this time.

Explanation: The JESLOG for the target domain in this test case is not available. The most likely cause is that the Test Supervisor did not execute the domain.

User Response: None.

ATV-RP102I Target Region may not be under ATV Operational Control

Explanation: Related to message ATV-RP101I. This is the most likely reason for the JESLOG not to be available for processing.

User Response: None.

ATV-RP107I ATV Performance Report Completed.

Explanation: Informational

User Response: None.

Page 27: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-13

ATV-RP118E ATV Performance Report Creation Ended with Errors. Return Code = rc.

Explanation: An error and/or an unacceptable return code was encountered during JESLOG Performance Report or Summary Performance Report Processing. The Return Code is listed.

User Response: Review the JESLOG for additional messages relating to the JESLOG or Summary Performance Report processing. If these do not identify the cause, contact Compuware Customer Support.

ATV-RP108I JCL Performance Report Completed.

Explanation: Informational

User Response: None.

ATVRVATVRV010I Symbolic substitution information

Explanation: Indicates the symbolic substitution data used for the current test case JCL asset.

System Action: Processing continues.

User Response: None.

ATV-SMATV-SM101I Return Code from Strobe call is: rc.

Explanation: Informational

User Response: None.

ATV-SM101W ATV Strobe Measurement Number is unavailable.

Explanation: The Strobe Measurement Number could not be found in the return data from the Strobe Measurement request.

User Response: None.

ATV-SM102I Processing For Strobe Measurement Initialization Complete

Explanation: Informational

User Response: None.

ATV-SM102W ATV Strobe Measurement for Region domain_name may not be available.

Explanation: Related to messages ATV-SM101W, ATV-SM103W, and ATV-SM104W. Due to any of these circumstances, Strobe Reporting may not be available, but Strobe Report Creation will be attempted.

User Response: None.

ATV-SM103I Process Completed.

Explanation: Informational

User Response: None.

ATV-SM103W ATV Strobe Return Code is unavailable.

Explanation: The Return Code could not be found in the return data from the Strobe Measurement Request

User Response: None.

ATV-SM104I ATV Strobe Measurement Number is: nnnn

Explanation: Informational

User Response: None.

Page 28: Hiperstation Messages and Codes

2-14 Hiperstation Messages and Codes

ATV-SM104W The Strobe Session Manager is not active or available.

Explanation: The Strobe Session Manager is not active or available on the System where the ATV is running.

User Response: Contact the System Administrator to have the Strobe Session Manager Started Task activated if Strobe Measurements are needed.

ATV-SM108E Strobe Measurement Initialization for region domain_name failed.

Explanation: The Strobe Measurement initialization request for the specified domain failed.

User Response: None.

ATV-SM109E See dataset dataset_name for details.

Explanation: Related to messages ATV-SM108E and ATV-SM110E. Due to either of these circumstances, the Strobe Measurement and Report will not be available.

User Response: Review the dataset dataset_name to identify the specific Strobe messages in question to identify the reason for the Strobe Measurement failure.

ATV-SM110E Strobe Execution for region domain_name failed.

Explanation: The Strobe execution process for the specified domain failed.

User Response: None.

ATV-SRATV-SR101E Return Code from Strobe Sample DSN validation call is: rc

Explanation: The Strobe Sample dataset name returned is not a valid Sample dataset.

User Response: None.

ATV-SR101I Strobe Delete Command Successfully Processed.

Explanation: Informational

User Response: None.

ATV-SR101W Return Code from Strobe call is: rc.

Explanation: The Return Code from the Strobe Command execution is rc. This is the Return Code generated by Strobe.

User Response: Check the Strobe Error Code Manual to identify the meaning behind the Return Code rc.

ATV-SR102E Report Processing Halted.

Explanation: The Strobe Report Processing has been halted.

User Response: None.

ATV-SR102W ATV Strobe Report for Region domain_name may not be available.

Explanation: Related to message ATV-SR101W. The Return Code for message ATV-SR101W indicates that the Strobe Report for region domain_name may not be available.

User Response: Check the Strobe Error Code Manual to identify the meaning behind the Return Code rc.

ATV-SR103W Strobe Measurement Session Not Active At Stop Time.

Explanation: The Strobe Command execution returned a value identifying that the specified Strobe Measurement Session was not active, thus it could not be stopped.

User Response: None.

ATV-SR104W Strobe Report Generation Proceeding.

Explanation: Related to message ATV-SR103W. If the Measurement's Sample dataset can be determined by the Performance Vehicle, the Strobe Report generation will be attempted.

Page 29: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-15

User Response: None.

ATV-SR105I Processing For Strobe Performance Report Complete.

Explanation: Informational

User Response: None.

ATV-SR105W Strobe Delete Command Not Processed Successfully.

Explanation: The Strobe Command execution of the DELETE command was not successful.

User Response: None.

ATV-SR106W See dataset dataset_name for details.

Explanation: Related to message ATV-SR105W. Identifies the dataset name the SYSOUT from the Strobe Command execution was written into.

User Response: Review the dataset dataset_name to identify the specific Strobe messages in question to identify the reason for the Delete Command failure.

ATV-SR107E Strobe Measurement Cancellation for region domain_name failed.

Explanation: The Strobe Measurement cancellation request for region domain_name failed.

User Response: None.

ATV-SR107I Strobe Report Creation Completed.

Explanation: Informational

User Response: None.

ATV-SR108E See dataset dataset_name for details.

Explanation: Related to messages ATV-SR101E, ATV-SR102E, and ATV-SR107E. The dataset dataset_name contains the SYSOUT output from the results of the previous message command actions.

User Response: Review the dataset dataset_name to identify the specific Strobe messages in question to identify the reason for the previous errors.

ATV-SR109E Return Code from Hiperstation Sample DSN validation call is: return_code

Explanation: Related to messages ATV-SR110E and ATV-SR111E. Due to the previous error(s), Strobe Report generation may not be executed.

User Response: Review the dataset name from message ATV-SR110E with the supplied return code to determine the cause of this error and correct it.

ATV-SR110E Dataset validated is: dataset_name.

Explanation: Related to messages ATV-SR109E and ATV-SR111E. Due to the previous error(s), Strobe Report generation may not be executed.

User Response: Review the Return Code from message ATV-SR109E with the supplied dataset name to determine the cause of this error and correct it.

ATV-SR111E Strobe Report generation may not be available.

Explanation: Related to messages ATV-SR110E and ATV-SR109E. Due to the previous error(s), Strobe Report generation may not be executed.

User Response: Review the Return Code from message ATV-SR109E to determine the error cause and correct it. The related messages provide the return code and specific dataset name for which this message applies.

ATVSUATVSU100I Test Run starting on dd mmm yyyy

Explanation: Documents the date and time the test run request began executing.

Page 30: Hiperstation Messages and Codes

2-16 Hiperstation Messages and Codes

System Action: Processing continues.

User Response: None.

ATVSU101I Test Run ending on dd mmm yyyy

Explanation: Documents the date and time the test run request finished executing.

System Action: Processing continues.

User Response: None.

ATVSU510E Control card read error

Explanation: Indicates that required test run request control cards were either missing or incorrect.

System Action: Test run processing terminates.

User Response: Contact Compuware Customer Support.

ATVSU511E Error reading vehicle(vclname) rc = n

Explanation: An error was encountered reading the vehicle information from the dataset specified on the INDEX_DSN control card. The database access program finished with returned code n.

System Action: Test run processing terminates.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered.

ATVSU512W Initialization setup error

Explanation: Detection of the current SYSNAME failed. Displays & reports may indicate invalid data as the system name.

System Action: Processing continues.

User Response: If this problem repeats, contact Compuware Customer Support.

ATVSU513E Test case list setup error: n

Explanation: An error was encountered reading the vehicle information from the ATVDBASE dataset. The database access program finished with returned code n.

System Action: Test run processing terminates.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered. If unable to resolve, contact Compuware Customer Support.

ATVSU518I Reading control cards

Explanation: Indicates control card processing has started.

System Action: Processing continues.

User Response: None.

ATVSU519I Input (aaa)

Explanation: Documents the text of a control card being processed.

System Action: Processing continues.

User Response: None.

ATVSU520E Runlog initialization error: n

Explanation: An error was encountered writing run data to the ATVDBASE dataset. The database access program finished with returned code n.

System Action: Test run processing terminates.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered. If unable to resolve, contact Compuware Customer Support.

Page 31: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-17

ATVSU521E Test execution failure

Explanation: An unrecoverable error was encountered while executing an individual test case.

System Action: Test run processing terminates.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered. If unable to resolve, contact Compuware Customer Support.

ATVSU522E Test execution reporting error

Explanation: An error was encountered producing the test run report.

System Action: Processing continues.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered. If unable to resolve, contact Compuware Customer Support.

ATVSU523E Email distribution error

Explanation: An error was encountered distributing the test run report via email.

System Action: Processing continues.

User Response: Inspect the JCLLOG messages, JESMSGLG, and SYSTSPRT from the test run job for associated messages explaining the specific error encountered. If unable to resolve, contact Compuware Customer Support.

ATVSU524I No email contacts defined to this vehicle

Explanation: Indicates no email contacts have been defined to this ATV.

System Action: Processing continues.

User Response: None.

ATVSU525I Email distribution disabled via profile setting

Explanation: Indicates report distribution has been disabled for this ATV.

System Action: Processing continues.

User Response: None.

ATVSU526I Email distribution suppressed by user request

Explanation: Indicates report distribution has been disabled via selection on the test run confirmation panel for this individual test run.

System Action: Processing continues.

User Response: None.

ATVSU528W No email address found for contact aaa

Explanation: Indicates a report distribution assignment was found for contact name aaa but contact information for aaa was not found.

System Action: Processing continues.

User Response: Add contact information for contact aaa using the Email Contacts facility on the Automated Testing Vehicle main menu panel.

ATVSU529I No contacts assigned to email distribution list

Explanation: Indicates no email contacts have been assigned to receive reports for the requested test run.

System Action: Processing continues.

User Response: None.

Page 32: Hiperstation Messages and Codes

2-18 Hiperstation Messages and Codes

ATVSU530I Waiting for aaa

Explanation: Test run execution is serialized within an automate testing vehicle using the MVS enqueue facility. The minor node used for this serialization is aaa.

System Action: Processing waits for the enqueue of aaa to be satisfied.

User Response: None.

ATVSU531I Obtained aaa

Explanation: Test run execution is serialized within an automate testing vehicle using the MVS enqueue facility. The minor node used for this serialization is aaa.

System Action: Processing continues.

User Response: None.

ATVSU560I Detail Dataset Name: aaa

Explanation: Documents the name of the dataset, aaa, that contains the detail run report for this test request.

System Action: Processing continues.

User Response: None.

ATVSU565I Summary Dataset Name: aaa

Explanation: Documents the name of the dataset, aaa, that contains the summary run report for this test request.

System Action: Processing continues.

User Response: None.

ATVSU566I Joblog Dataset Name: aaa

Explanation: Documents the name of the dataset, aaa, that contains the job execution log messages for this test request.

System Action: Processing continues.

User Response: None.

ATVSU570I Test cases selected: n

Explanation: Documents the number of test cases that belong to the item requested to run.

System Action: Processing continues.

User Response: None.

ATVSU575I Test cases passed: n

Explanation: Documents the number of test cases that have been determined to have passed for the test run requested.

System Action: Processing continues.

User Response: None.

ATVSU580I Test cases failed: n

Explanation: Documents the number of test cases that have been determined to have failed for the test run requested.

System Action: Processing continues.

User Response: None.

ATVSU585I Test cases skipped: n

Explanation: Documents the number of test cases that belong to the item requested to run, but are in a status that does not allow it to run for production requests, that is a full vehicle or playlist.

System Action: Processing continues.

Page 33: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-19

User Response: None.

ATVTEATVRV010I Symbolic substitution information

Explanation: Indicates the symbolic substitution data used for the current test case JCL asset.

System Action: Processing continues.

User Response: None.

ATVTE100I Submitted job dsn as jobident

Explanation: Documents a replay job was submitted while running a test case. The JCL was in dataset dsn and the job identity is jobident

System Action: Processing continues.

User Response: None.

ATVTE101W Could not pre-delete output dsn

Explanation: Test executor was preparing to send job output to dataset dsn, but was unable to delete the dataset.

System Action: System retries delete.

User Response: None.

ATVTE102E Unable to pre-delete output dsn

Explanation: Test executor failed to delete dataset dsn. Job output is not available to determine results.

System Action: Test case fails.

User Response: Review the test run joblog for additional details. If unable to resolve the error, contact Customer Support.

ATVTE103E Error rc saving job output for test case step n jobident jobident

Explanation: Test executor failed to print output for job jobident. "TSO OUTPUT" command returned code rc. Job output is not available to determine results. The job was submitted for the nth step in the current test case.

System Action: Test case fails.

User Response: Review the test run joblog for additional details. Insure the MSGCLASS on the JOBCARD for job jobident will send the job output to the JES HELD queue. If unable to resolve the error, contact Customer Support.

ATVTE104E JCL Error, see dsn for detail

Explanation: Test executor detected a failure of a test case step.

System Action: Test case fails.

User Response: View contents of dsn to identify the detected error. If unable to resolve error, contact Compuware Customer Support.

ATVTE104W Possible problem getting output, retry in 3 seconds

Explanation: Test executor failed to print output.

System Action: Processing continues.

User Response: Review the test run joblog for additional messages. Insure the MSGCLASS on the JOBCARD for job jobident will send the job output to the JES HELD queue.

ATVTE105E Unable to allocate dsn, compare analysis skipped.

Explanation: Test executor was unable to allocate dataset dsn during compare analysis for remediation data.

Page 34: Hiperstation Messages and Codes

2-20 Hiperstation Messages and Codes

System Action: Processing continues.

User Response: Note: Script remediation may not be available for this test case following this test case run.

ATVTE107E Non-numeric RC= rc in dsn.

Explanation: ATV job result scan found a non-numeric value, rc, as a job step return code.

System Action: Test case fails.

User Response: View contents of dsn to determine the reason. If your site has non-standard JES message log or JES system messages you may need to code a site specific JCL return code detection exit, RCDETECT. If unable to resolve the error, contact Compuware Customer Support.

ATVTE108E No jobsteps completed.

Explanation: ATV job result scan did not find a job step return code.

System Action: Test case fails.

User Response: View contents of dsn to determine the reason. If your site has non-standard JES message log or JES system messages you may need to code a site specific JCL return code detection exit, RCDETECT. If unable to resolve the error, contact Compuware Customer Support.

ATVTE110I Running test case (tcsname)

Explanation: Indicates the test case executor has started running test case tcsname.

System Action: Processing continues.

User Response: None.

ATVTE111I Test case ended (tcsname)

Explanation: Indicates the test case executor has finished running test case tcsname.

System Action: Processing continues.

User Response: None.

ATVTE112E JCL asset member aaaaaaaa not found.

Explanation: JCL asset member aaaaaaaa is defined to this vehicle but is not in the JCL library for this vehicle.

System Action: Test case execution stops, set result to FAIL.

User Response: Place the intended JCL member, aaaaaaaa, into the vehicle’s JCL library.

ATVTE113E JCL asset member aaaaaaaa is empty.

Explanation: The JCL asset member aaaaaaaa is empty.

System Action: Test case execution stops, set result to FAIL.

User Response: Place the intended JCL into member aaaaaaaa in the vehicle’s JCL library.

ATVTE114E Failure initiating JCL asset aaaaaaaa.

Explanation: Unable to run JCL asset aaaaaaaa. Likely cause is that the asset was deleted after inclusion into this test case.

System Action: Test case execution stops, set result to FAIL.

User Response: Add the intended JCL asset aaaaaaaa to the vehicle, or remove the asset from this test case.

ATVTE120W Unable to update output dataset name in the iSTROBE JCL.

Explanation: Related to Messages ATVTE121W and ATVTE122W. The iStrobe Output dataset name was not created in the standard format; that being the same as the standard Strobe Sample dataset name substituting 'S' with an 'X' in the low lever qualifier.

System Action: iStrobe Report Creation processing is halted; however other Test Case Processing continues.

Page 35: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-21

User Response: See Message ATVTE122W for steps to take in determining what happened.

ATVTE121W Input STROBE sample dataset is not in the standard format.

Explanation: Related to Messages ATVTE120W and ATVTE122W. The iStrobe Output dataset name was not properly created in the standard format; that is based on the input Strobe Sample dataset name.

System Action: iStrobe Report Creation processing is halted; however other Test Case Processing continues.

User Response: See Message ATVTE122W for steps to take in determining what happened.

ATVTE122W Strobe Sample dataset does not exist

Explanation: Related to Messages ATVTE120W and ATVTE121W. The Strobe Sample Dataset identified by the Strobe Measurement session does not exist.

System Action: iStrobe Report Creation processing is halted; however other Test Case Processing continues.

User Response: Validate that the Strobe Sample dataset identified by the Strobe Measurement session exists, is catalogued, and can be accessed from the system on which the Test Case executioner is operating.

ATVTE123W Strobe Sample dataset is dsn

Explanation: Related to Messages ATVTE120W, ATVTE121W and ATVTE122W. The Strobe Sample dataset name is displayed, if it exists.

System Action: iStrobe Report Creation processing is halted; however other Test Case Processing continues.

User Response: The dataset name is used in determining the cause for the previous messages.

ATVTE124W Test case tcsname has no elements.

Explanation: No test steps are defined to test case tcsname.

System Action: Processing continues.

User Response: Add test steps to test case tcsname to accomplish its test requirements.

ATVTE130E Unable to save region log to dataset

Explanation: Allocation of the dataset to contain the region log failed, causing the retrieval of the Region log from JES to fail.

System Action: Processing continues.

User Response: Examine the System Log to determine the cause of the Allocation failure and correct it.

ATVTE131E Unable to allocate tempdsn for log

Explanation: Allocation of the temporary dataset to contain the region log failed, causing the Region Job ID to be unavailable.

System Action: Processing continues.

User Response: Examine the System Log to determine the cause of the Allocation failure and correct it.

ATVTE150I Asset Executed - Jobname: jobname Jobid: jobid

Explanation: Identifies a job that has been submitted during a test case run

System Action: Processing continues.

User Response: None.

ATVTE155I Strobe Measurement Disabled per Settings.

Explanation: The execution of a Strobe Measurement for the current Region Asset has been halted per User settings specified in the Test Case Region Asset details.

System Action: Processing continues.

Page 36: Hiperstation Messages and Codes

2-22 Hiperstation Messages and Codes

User Response: If a Strobe Measurement is required, update the Test Case Region Asset details otherwise no action is needed.

ATVTE160I Unable to determine CICS Region Initiator Status, or Startup JCL condition.

Explanation: Related to message ATVTE161I. The ATV is unable to determine how the CICS Region was started or if the Startup JCL specified in the Region Asset is valid.

System Action: Processing continues.

User Response: None.

ATVTE161I Attempting Strobe Measurement.

Explanation: Related to message ATVTE160I. The ATV is attempting to initiate a Strobe Measurement.

System Action: Processing continues.

User Response: None.

ATVTE162I Indeterminate CICS Region Status. Attempting Strobe Measurement.

Explanation: The ATV is unable to determine the Execution status of the CICS Region. A Strobe Measurement will be attempted.

System Action: Processing continues.

User Response: None.

ATVTE201I ATV options directive {a}

Explanation: An ATV option directive was found in a JCL asset. The directive found is a.

System Action: Processing continues.

User Response: None.

ATVTE202I JCL dsn ATV option set WAIT to v

Explanation: The wait value was set to v for a JCL asset, show in dataset dsn, during the test case run.

System Action: Processing continues.

User Response: None.

ATVTE410E ABEND a in dsn

Explanation: A system abend, with the code a, was detected during the test case run.

System Action: Test case fails.

User Response: Review results to determine cause.

ATVTE411E ABEND a in dsn

Explanation: A user abend, with the code a, was detected during the test case run.

System Action: Test case fails.

User Response: Review results to determine cause.

ATVTE500E Unable to Allocate Strobe Load Library

Explanation: Allocation of strobe load library failed.

System Action: Test case fails.

User Response: Verify the proper load library is specified. Associated message ATVA510E indicates the expected library DSN.

ATVTE501I Testcase tcsname failed.

Explanation: Indicates the test run result for test case tcsname is Fail.

System Action: Processing continues

User Response: Review test case results to determine cause.

Page 37: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-23

ATVTE502E Unable to Allocate Strobe Hist Library

Explanation: Allocation of strobe History library failed.

System Action: Test case fails.

User Response: Verify the proper library is specified. Associated message ATVA503E indicates the expected library DSN.

ATVTE503E Specified HIST Library is: dsn

Explanation: Indicates the library defined as the strobe HIST is dsn

System Action: Test case fails.

User Response: None.

ATVTE504E Unable to Allocate Strobe Path Library

Explanation: Allocation of strobe path failed.

System Action: Test case fails.

User Response: Verify the proper library is specified. Associated message ATVA505E indicates the expected library DSN.

ATVTE505E Specified Path Library is: dsn

Explanation: Indicates the library defined as the strobe Path is dsn.

System Action: Test case fails.

User Response: None.

ATVTE506E Unable to Allocate Strobe Log Library

Explanation: Allocation of strobe log failed.

System Action: Test case fails.

User Response: Verify the proper library is specified. Associated message ATVA507E indicates the expected library DSN.

ATVTE507E Specified Log Library is: dsn

Explanation: Indicates the library defined as the strobe Log is dsn.

System Action: Test case fails.

User Response: None.

ATVTE510E Specified Load Library is: dsn

Explanation: Indicates the library defined as the strobe Load lib is dsn

System Action: Test case fails.

User Response: None.

ATVTE524I No contacts specified for function a failure notification.

Explanation: A test case assigned to function a failed. Because no contact has been assigned to function a, no failure notice can be sent

System Action: Processing continues.

User Response: None.

ATVTE525I Email distribution disabled via profile setting.

Explanation: All email functions are disabled via the profile setting for disabling email report distribution.

System Action: Processing continues.

User Response: None.

Page 38: Hiperstation Messages and Codes

2-24 Hiperstation Messages and Codes

ATVTE526I Email distribution suppressed by user request.

Explanation: All email functions are disabled by user request entered on the test run confirmation panel.

System Action: Processing continues.

User Response: None.

ATVTE527I No email contacts defined to vehicle.

Explanation: The vehicle has no email report distribution defined.

System Action: Processing continues.

User Response: None.

ATVTE528W No email address found for contact a

Explanation: An email distribution assignment was found for contact a, but no email contact information was found for contact a.

System Action: Processing continues.

User Response: Add contact a as a new contact via the ATV Email user interface.

ATVTE580I Email sent to a b

Explanation: An email was sent to contact a using email address b.

System Action: Processing continues.

User Response: None.

CLOGGENCLOGGEN-0001E ERROR MAKING ROOT DIRECTORY: <root> RC = <return code>

Explanation: The CLOGGEN program could not create the root directory specified on the CLOGDIR parameter.

System Action: Report conversion is terminated.

User Response: Verify that a valid HFS Directory was specified on the CLOGDIR parameter and that all of the directories in the specified path exist. Also, be sure you have authority to write to the location specified on the CLOGDIR parameter. Refer to the IBM UNIX System Services Manual for information regarding MKDIR command.

CLOGGEN-0002I PROCESSING COMPLETE FOR: <clog>

Explanation: This message notifies you when the specified Compare Log, Exception Log, or Onelog has been converted.

CLOGGEN-0003I READING INPUT PARAMETERS

Explanation: This message appears at the beginning of the conversion job. It is a status message.

CLOGGEN-0004E CLOG PARM NOT DETECTED, PROCESSING TERMINATED.

Explanation: Either a CLOG parameter is not specified in the job, or the syntax of the parameter is incorrect.

System Action: Report conversion terminated.

User Response: Ensure that the CLOG parameter exists and is syntactically correct. Refer to the Hiperstation for VTAM User Guide for information regarding conversion job parameters.

CLOGGEN-0005E INPUT DATASET: <clog> IS NOT IN SEQUENTIAL OR PARTITIONED FORMAT.

Explanation: The dataset specified on the CLOG parameter is not a sequential dataset or PDSE.

System Action: Processing for the specified dataset or PDSE member is terminated.

Page 39: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-25

User Response: Ensure the CLOG parameter points to a sequential dataset or a PDSE.

CLOGGEN-0006I READING COMPARE LOG INTO MEMORY: <clog>

Explanation: This message appears during conversion. It is a status message.

CLOGGEN-0007E ERROR OPENING INPUT COMPARE LOG DATASET, RC: <return code> <clog>

Explanation: The CLOGGEN program could not ALLOCATE the specified Compare Log, Exception Log, or Onelog dataset for opening.

System Action: Report conversion terminated.

User Response: Ensure the dataset specified on the CLOG parameter exists, is a Compare Log, Exception Log, or Onelog, and is proprerly qualified. Refer to IBM’s documentation for TSO ALLOCATE command return codes.

CLOGGEN-0008E ERROR READING INPUT COMPARE LOG DATASET, RC: <return code> <clog>

Explanation: The EXECIO DISKR command used to read the specified Compare Log, Exception Log, or Onelog dataset failed.

System Action: Report conversion terminated.

User Response: Refer to IBM REXX documentation for EXECIO DISKR return code information.

CLOGGEN-0009E INPUT DATASET - <clog> IS NOT A VALID LOG.

Explanation: The dataset specified on the CLOG parameter does not contain a correctly formatted Compare Log, Exception Log, or Onelog.

System Action: Report conversion terminated.

User Response: Ensure the CLOG parameter points to an unedited Compare Log, Exception Log, or Onelog dataset. If the specified dataset is a Compare Log, Exception Log, or Onelog that has been edited, regenerate the log and try again. If it has not been edited, call Compuware Customer Support.

CLOGGEN-0010I INPUT DATASET - <clog> SKIPPED FOR PROCESSING.

Explanation: The specified dataset does not contain Compare Log, Exception Log, or Onelog information, and therefore it will not be processed.

CLOGGEN-0011I ONELOG DETECTED FOR: <clog>

Explanation: This is an informational message indicating that the dataset specified on the CLOG parameter is a Onelog.

CLOGGEN-0012E ERROR MAKING CLOG DIRECTORY: <path> RC: <return code>

Explanation: HFS directory creation failed.

System Action: Report conversion terminates.

User Response: Verify that the HFS directory specified on the CLOGDIR parameter is valid and that the necessary security authorization for the MKDIR command is in place. Refer to IBM UNIX System Server documentation regarding return codes associated with the MKDIR command.

CLOGGEN-0013I PROCESSING COMPARE LOG SCREENS FOR TERMINAL# <terminal-number>

Explanation: Status message to inform you of conversion progress for the specified Onelog.

CLOGGEN-0014I PROCESSING COMPARE LOG SCREENS

Explanation: Status message to inform you of conversion progress.

CLOGGEN-0015E ERROR WRITING ACTUAL/EXPECTED PAGE: <file> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page containing an Actual/Expected screen pair to the specified file.

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

Page 40: Hiperstation Messages and Codes

2-26 Hiperstation Messages and Codes

CLOGGEN-0016I CREATING SCREEN SUMMARIES

Explanation: Status message to inform you of conversion progress.

CLOGGEN-0017E ERROR WRITING LISTINGS PAGE: <listfile> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file.

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0018E ERROR WRITING FIND PAGE: <writefile> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file.

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command

CLOGGEN-0019E ERROR WRITING STATISTICS FILE: <statfile> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file.

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0020I CREATING MAIN PAGES

Explanation: Status message to inform you of conversion progress.

CLOGGEN-0021E ERROR WRITING MAIN PAGE: <mainfile> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file.

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0022I CREATING/UPDATING HOME PAGE

Explanation: Status message to inform you of conversion progress.

CLOGGEN-0023E ERROR READING DIRECTORY: <rootpath> RC: <return code>

Explanation: The directory specified on the CLOGDIR parameter could not be accessed by the READDIR command.

System Action: Report conversion is terminated.

User Response: Ensure that the CLOGDIR parameter is correctly specified. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the READDIR command.

CLOGGEN-0024E ERROR READING STATISTICS FILE: <stats> RC: <return code>

Explanation: The READFILE command could not access the named file (<stats>).

System Action: Report conversion is terminated.

User Response: Ensure that the named file exists. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the READFILE command.

CLOGGEN-0025E ERROR WRITING HOME PAGE: <home_page> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file (<home_page>).

System Action: Report conversion is terminated.

Page 41: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-27

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0026I CREATING COMPARE LOG SUMMARY PAGE

Explanation: Status message to inform you of conversion progress.

CLOGGEN-0027E ERROR WRITING SUMMARY PAGE: <summary> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file (<summary>).

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0028E ERROR WRITING SETCOLORS PAGE: <setcolors> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the specified file (<setcolors>).

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0029W WILDCARDING THE LOG DATASET FOR DELETE NOT SUPPORTED. DELETE REQUIRES A FULLY QUALIFIED LOG DATASET.

Explanation: The dataset specified on the CLOG parameter contains a wildcard character (*), which is not supported by the DELETE option.

System Action: Files are not deleted.

User Response: Either remove the DELETE parameter or the wildcard character from the CLOG parameter.

CLOGGEN-0030E ERROR READING DIRECTORY FOR DELETION: <path> RC: <return code>

Explanation: The READDIR command could not access the specified directory (<path>).

System Action: Report conversion is terminated.

User Response: Verify that the named directory exists. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the READDIR command.

CLOGGEN-0031E ERROR DELETING DIRECTORY: <dir-entry> RC: <return code>

Explanation: The RMDIR command could not delete the named directory (<dir-entry>).

System Action: Report conversion is terminated.

User Response: Verify that the named directory exists. If necessary refer to IBM UNIX System Server documentation regarding return codes associated with the RMDIR command.

CLOGGEN-0032E ERROR DELETING FILES IN: <dir-entry> RC: <return code>

Explanation: The UNLINK command could not release the files in the specified directory (<dir-entry>).

System Action: Report conversion is terminated.

User Response: Verify that the named directory exists. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the UNLINK command.

CLOGGEN-0033E ERROR DELETING LOG DIRECTORY: <path> RC: <return code>

Explanation: The RMDIR command could not delete the named directory (<path>).

System Action: Report conversion is terminated.

User Response: Verify that the named directory exists. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the RMDIR command.

Page 42: Hiperstation Messages and Codes

2-28 Hiperstation Messages and Codes

CLOGGEN-0034I LOG <clog> DELETED FROM WEBSITE <path>

Explanation: Information message reporting the successful deletion of the named Comparison, Exception, or Onelog report (<clog>) from the named HFS directory (<path>).

CLOGGEN-0035I NO MATCHING LOG DATASETS FOUND BY LISTCAT, RC: <return code>

Explanation: Information message explaining that no log datasets were found.

User Response: Ensure the CLOG parameter points to a Compare Log, Exception Log, Onelog dataset.

CLOGGEN-0036E INPUT DATASET: <clog> FAILED LISTDSI. RC: <listdsi_return code>

Explanation: The LISTDSI command could not access the named Compare Log, Exception Log, or Onelog (<clog>).

System Action: Report conversion is terminated.

User Response: Verify that the named dataset exists and is either a sequential dataset or PDS(E) member.

CLOGGEN-0037E INPUT DATASET: <clog> FAILED SYSDSN. RC:<sysdsn_return code>

Explanation: The SYSDSN command could not access the named Compare Log, Exception Log, or Onelog dataset (<clog>).

System Action: Report conversion is terminated.

User Response: Verify that the named dataset exists and is either a sequential dataset or PDS(E) member.

CLOGGEN-0038E ERROR WRITING LOAD PAGE: <loadfile> RC: <return code>

Explanation: The WRITEFILE command could not write the generated HTML page to the named file (<loadfile>).

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0039E ERROR WRITING JS JAVASCRIPT FILE: <js_file> RC: <return code>

Explanation: The WRITEFILE command could not write the generated JavaScript to the named file (<js_file>).

System Action: Report conversion is terminated.

User Response: Refer to IBM UNIX System Server documentation regarding return codes associated with the WRITEFILE command.

CLOGGEN-0040E ERROR MAKING COMMON DIRECTORY: <common> RC: <return code>

Explanation: The MKDIR command could not create the named HFS directory (<common>).

System Action: Report conversion is terminated.

User Response: Verify that the CLOGDIR parameter specifies a valid HFS directory name and that the necessary security authorization for the MKDIR command is in place. If necessary, refer to IBM UNIX System Server documentation regarding return codes associated with the MKDIR command.

CLOGGEN-0041E TRANS PARAMETERS MUST BE INTEGERS.

Explanation: One or more of the TRANS parameter values (row,column,length) are not integers.

System Action: Report conversion is terminated.

User Response: Change the TRANS parameter values to integers.

CLOGGEN-0042E CLOGDIR PARM NOT DETECTED, PROCESSING TERMINATED.

Explanation: The conversion job does not contain a CLOGDIR parameter.

System Action: Processing is terminated.

Page 43: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-29

User Response: Add the CLOGDIR parameter to the job. Refer to the Hiperstation for VTAM User Guide for more information on CLOGGEN parameters.

CLOGGEN-0043E LISTMAX PARAMETER MUST BE AN INTEGER.

Explanation: The LISTMAX parameter value is not an integer.

System Action: Report conversion is terminated.

User Response: Change the LISTMAX value to an integer.

CLOGGEN-0044I HIPERSTATION WEB COMPARE LOG VIEWING PROCESSOR RELEASE 'XX.XX.XX' BUILD' XX

Explanation: Information message to inform the user of the Hiperstation product release and build number.

CLOGGEN-0045E ERROR SETTING UP USS COMMAND ENVIRONMENT

Explanation: An error has occurred establishing USS command environment.

System Action: Processing Terminated.

User Response: Check with system's programmer to ensure USS command environment is available.

E62ALTMPE62ALTMP1E DATASET LRECL(lllll) FOR dddddddd IS TOO SMALL

Explanation: The dataset dddddddd has a logical record length (LRECL) of lllll. This LRECL is too small to support the data that Hiperstation for Mainframe Servers is trying to write.

User Response: Supply a dataset that has a larger LRECL for your conversation log, script, or detail. Datasets used by Hiperstation for Mainframe Servers for APPC data must have an LRECL of at least 72.

E62ALTMP2E THE dddddddd DATASET MUST HAVE AN LRECL OF AT LEAST lllll

Explanation: The dataset dddddddd is allocated with a logical record length (LRECL) that is insufficient for the data that Hiperstation for Mainframe Servers is trying to write.

User Response: Delete and reallocate the dataset with an LRECL of at least lllll.

E62ALTMP3E DATASET INFO NOT AVAILABLE FOR dddddddd

Explanation: Hiperstation for Mainframe Servers could not obtain information, such as record format and logical record length, for dataset dddddddd.

User Response: Verify that dataset dddddddd exists and is cataloged. If the dataset exists and is cataloged, an internal processing error may have occurred. Contact Compuware Customer Support for assistance.

E62ALTMP4E PROBLEM ENCOUNTERED ALLOCATING THE TEMPORARY tttttttt DATASET:

Explanation: Hiperstation for Mainframe Servers could not allocate (create) a temporary dataset needed during script creation. It uses temporary datasets for the conversation log, script, and detail datasets.

User Response: A probable cause of this failure is insufficient space on the DASD volume Hiperstation for Mainframe Servers is using for temporary datasets. See the accompanying message E62ALTMP5E for this failure’s dynamic allocation codes. IBM’s z/OS MVS Programming: Authorized Assembler Services Guide describes these codes.

E62ALTMP5E R15 rr, S99ERROR eeee, S99INFO iiii, S99ERSN ssss

Explanation: Hiperstation for Mainframe Servers could not allocate (create) a temporary dataset needed during script creation.

• Value rr was found in R15 on completion of the MVS DYNALLOC macro.• Value eeee was found in the S99ERROR field on completion of the MVS DYNALLOC

macro.• Value iiii was found in the S99INFO field on completion of the MVS DYNALLOC macro.

Page 44: Hiperstation Messages and Codes

2-30 Hiperstation Messages and Codes

• Value ssss was found in the S99ERSN field on completion of the MVS DYNALLOC macro.

A description of these codes can be found in IBM’s MVS/ESA Programming: Authorized Assembler Services Guide.

User Response: Take whatever corrective action is indicated by the MVS DYNALLOC return codes. Temporary dataset allocation failure is typically due to insufficient space on the DASD volume Hiperstation for Mainframe Servers is using.

E62CPFILE62CPFILAI OUTBOUND DETAIL: mmmmmmmm, CREATED IN: dddddddd

Explanation: Dataset member mmmmmmmm was written to dataset dddddddd. The member contains outbound detail data for an APPC conversation.

User Response: An informational message only. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFILBI PLU: pppppppp, SLU: ssssssss, LOGMODE: llllllll

Explanation: This message is part of a set produced when a log, script, or detail data is written to a user’s dataset. The APPC conversation being recorded was between a primary logical unit (PLU) named pppppppp and a secondary logical unit (SLU) named ssssssss. The logon mode name (LOGMODE) used by the VTAM session is llllllll.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFILCI TP: tttttttt

Explanation: This message is part of a set produced when a log, script, or detail data is written to a user’s dataset. The APPC conversation being recorded was for a transaction program (TP) named tttttttt. The TP will be shown in hexadecimal format if it contains nonprintable characters. A TP can be from 1 to 64 characters long.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFILDI

Explanation: This is a separator line written before messages describing a script, detail, or log that is being written to a user’s dataset.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFILEI LOG CREATED IN: dddddddd

Explanation: A conversation log was written to sequential dataset dddddddd.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFILFI DSNAME(dddddddd) RC(cc)

Explanation: A user’s dataset, dddddddd, could not be allocated.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62CPFIL1E PERMANENT tttttttt WRITE FAILURE:

Explanation: Hiperstation for Mainframe Servers could not successfully write all data to a user’s dataset. tttttttt indicates the type of data that was being written, which includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: The dataset or the DASD volume containing the dataset may be full. Ensure that there is available space in the dataset, the dataset directory, and the DASD volume.

Page 45: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-31

E62CPFIL2I DDNAME(ffffffff) DSNAME(dddddddd) RC(cc)

Explanation: Hiperstation for Mainframe Servers could not successfully open or write to dataset dddddddd.

System Action: Check for previous messages that describe the problem with the dataset and ensure that:

• The dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user• There is available space in the dataset, the dataset directory, and the DASD volume• The global recording job (usually a started task) has authority to read from and write to

the dataset.

E62CPFIL3E PERMANENT tttttttt FAILED TO OPEN

Explanation: Hiperstation for Mainframe Servers could not successfully open a user’s dataset. tttttttt indicates the type of data being processed, which includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: Check for messages before this one that describe the problem with the dataset and ensure that:

• The dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user• The global recording job (usually a started task) has authority to read from and write to

the dataset.

E62CPFIL4E PERMANENT tttttttt FAILED TO ALLOCATE

Explanation: Hiperstation for Mainframe Servers could not successfully allocate a user’s dataset. tttttttt indicates the type of data being processed, which includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: Check for messages before this one that describe the problem with the dataset. Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62CPFIL5E TEMPORARY tttttttt FAILED TO OPEN DDNAME(dddddddd), RC(return code)

Explanation: Hiperstation for Mainframe Servers could not successfully open a temporary work dataset that it had previously written to. tttttttt indicates the type of data being processed and includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: This message could indicate a DASD problem or an internal error in Hiperstation for Mainframe Servers. Contact Compuware Customer Support if this message occurs.

E62CPFIL6I LOG: mmmmmmmm, CREATED IN: dddddddd

Explanation: Dataset member mmmmmmmm was written to dataset dddddddd. The member contains the conversation log for one or more APPC conversations.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFIL7I SCRIPT: mmmmmmmm, CREATED IN: dddddddd

Explanation: Dataset member mmmmmmmm was written to dataset dddddddd. The member contains a script for a single APPC conversation.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFIL8I COMBINED DETAIL: mmmmmmmm, CREATED IN: dddddddd

Explanation: Dataset member mmmmmmmm was written to dataset dddddddd. The member contains all of the detail data for a single APPC conversation.

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62CPFIL9I INBOUND DETAIL: mmmmmmmm, CREATED IN: dddddddd

Explanation: Dataset member mmmmmmmm was written to dataset dddddddd. The member contains the inbound detail data for a single APPC conversation.

Page 46: Hiperstation Messages and Codes

2-32 Hiperstation Messages and Codes

User Response: Informational message. Can be suppressed by setting different notification options when creating the recording request under ISPF.

E62DSINFE62DSINF1E COULD NOT OBTAIN INFORMATION FOR dddddddd

Explanation: Hiperstation for Mainframe Servers could not obtain dataset information (record format, record length, and so forth) for dddddddd.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62DSINF2E DATASET LOCATE/OBTAIN RC(cc)

Explanation: Hiperstation for Mainframe Servers could not locate a user’s dataset or could not obtain information about the dataset.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62DSINF3E COULD NOT LOCATE DATASET dddddddd

Explanation: Hiperstation for Mainframe Servers could not locate dataset dddddddd.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62EVALPE62EVALP1E SEGMENTED DATA IS NOT MARKED REQ AND FMD, PIUTOD(tttttttt) RH(rrrrrr)

Explanation: Hiperstation for Mainframe Servers was interpreting an APPC data stream and found data that was not valid. The data was segmented into multiple Path Information Units (PIUs) and did not form a complete APPC logical record.

User Response: Ensure that the APPC application is sending valid APPC data streams. If you believe the data streams are valid, contact Compuware Customer Support.

E62EVALP2E E62EVALP: UNEXPECTED RESULT FROM tttttttt, RC=cc

Explanation: Hiperstation for Mainframe Servers encountered an internal error while interpreting APPC data.

User Response: Contact Compuware Customer Support.

E62EVALP3E UNPROCESSED DATA REMAINING, FLAG(ff)

Explanation: Hiperstation for Mainframe Servers was interpreting APPC data and came to the end of the data stream while expecting more data.

User Response: Ensure that the APPC application is sending valid APPC data streams. If the APPC application ended abnormally, it may have sent an incomplete data stream. If you believe the data streams are valid, contact Compuware Customer Support.

E62FILCLE62FILCL1E COULD NOT CREATE MEMBER WITH STOW, DDNAME(dddddddd) R15(cccc)

Explanation: Hiperstation for Mainframe Servers attempted to create a member in a user’s PDS but failed. This message is not issued if the dataset directory is full; message E62FILCL3E is issued.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user. Ensure that the dataset is not full (occupies all 16 extents) and that the DASD volume containing the dataset is not full.

Page 47: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-33

E62FILCL2E FILE CLOSE FOR DDNAME=dddddddd, RC=cc

Explanation: Hiperstation for Mainframe Servers could not successfully close the user’s dataset.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62FILCL3E PDS DIRECTORY FOR dddddddd IS FULL

Explanation: Hiperstation for Mainframe Servers could not create a member in the user’s dataset, dddddddd, because the dataset directory is full.

User Response: Remove members from the dataset or record the data into a different dataset.

E62FILCL51E UNRECOGNIZED FMH5 DATA REMAIN(rr) RU(dddddddd)

Explanation: Hiperstation for Mainframe Servers was interpreting a Function Management Header type 5 (FMH5), which represents an APPC ALLOCATE verb, and found more data than what was expected. The number of extra bytes is rr. The first sixteen bytes (at most) of the extra data is shown in dddddddd.

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that the FMH5 is valid.

E62PF5PIE62PF5PI1E INVALID PIP SUBFIELD HEADER PIP #(nn) GDS ID(gggg)

Explanation: A Program Initialization Parameter (PIP) subfield sent after an FMH5 contains an invalid Generalized Data Stream (GDS) ID. The incorrect GDS ID that was found is gggg. The nn indicates which of several subfields was in error (1, 2, etc.).

User Response: The correct value for a PIP subfield GDS ID is ‘12E2’x. Ensure that the APPC application is sending valid APPC data streams. Ensure that the PIP subfield GDS ID is correct.

E62PF5PI2E INVALID PIP VARIABLE HEADER GDS ID(gggg)

Explanation: The Program Initialization Parameter (PIP) variable sent after an FMH5 contains an invalid Generalized Data Stream (GDS) ID. The incorrect GDS ID that was found is gggg.

User Response: The correct value for a PIP variable GDS ID is ‘12F5’x. Ensure that the APPC application is sending valid APPC data streams. Ensure that the PIP variable GDS ID is correct.

E62PFMHE62PFMH53E INVALID PIP VALUE LENGTH(ll)

Explanation: The length field describing all of the Program Initialization Parameters (PIP) sent after a Function Management Header type 5 (FMH5) has a value of less than four. Its detected value is ll.

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that the FMH5 and PIP data are valid.

E62PFMH54E INVALID FMH5: TPNAME LENGTH

Explanation: The Transaction Program name (TPNAME) contained in a Function Management Header type 5 (FMH5) has a length of zero or a length greater than sixty-four.

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that the FMH5 is valid. The TPNAME in an APPC ALLOCATE verb must be from 1 to 64 bytes long.

E62PFMH55E INVALID FMH5: LUW LENGTH

Explanation: The Logical Unit of Work (LUW) field contained in a Function Management Header type 5 (FMH5) has a length of more than twenty-six (26) bytes.

Page 48: Hiperstation Messages and Codes

2-34 Hiperstation Messages and Codes

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that the LUW fields in the FMH5 are valid. The LUW length field identifies the total length of the following:

• A one-byte field identifying the LUW name length• Up to seventeen bytes for the LUW name• Six bytes for the LUW instance number• Two bytes for the LUW sequence number.

E62PFMH56E INVALID FMH5: LUWNAME LENGTH

Explanation: The Logical Unit of Work (LUW) name field contained in a Function Management Header type 5 (FMH5) has a length of more than seventeen (17) bytes.

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that the LUW name field in the FMH5 is valid.

E62PRMFAE62PRMFA1E DSORG oo NOT SUPPORTED, DSN(dddddddd)

Explanation: Hiperstation for Mainframe Servers found that the dataset organization (DSORG) of a user’s dataset dddddddd was not one of the supported values.

User Response: The conversation log may be physical sequential (PS) or partitioned (PO). The script and detail datasets must be partitioned.

E62PRMFA3E DATASET dddddddd MUST NOT BE SEQUENTIAL

Explanation: Hiperstation for Mainframe Servers found that the dataset organization (DSORG) of a user’s dataset dddddddd was physical sequential (PS) when it needs to be partitioned (PO).

User Response: The script and detail datasets must be partitioned datasets (PDS).

E62PRMFA4E PROBLEM ENCOUNTERED ALLOCATING THE tttttttt DATASET, RC(cc)

Explanation: Hiperstation for Mainframe Servers could not allocate a user’s dataset. tttttttt indicates the type of data being processed and includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62PRMFSE62PRMFS1E LRECL FOR dddddddd IS TOO SMALL

Explanation: Hiperstation for Mainframe Servers found that the logical record length (LRECL) of a user’s dataset dddddddd is too small to be successfully used for recorded data.

User Response: Use datasets that have an LRECL of at least 72.

E62PRMFS2E THE tttttttt DATASET MUST HAVE AN LRECL OF AT LEAST 72

Explanation: Hiperstation for Mainframe Servers found that the logical record length (LRECL) of a user’s dataset is too small to be successfully used for recorded data. tttttttt indicates the type of data being processed and includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

User Response: Use datasets that have an LRECL of at least 72.

E62PRMFS3E FILE ALLOCATION FAILED FOR tttttttt

Explanation: Hiperstation for Mainframe Servers could not allocate a user’s dataset. tttttttt indicates the type of data being processed and includes the conversation log, recording script, combined detail, inbound detail, and outbound detail.

Page 49: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-35

User Response: Ensure that the dataset exists, is cataloged, and is not allocated with DISP=OLD by another job or user.

E62PRUDTE62PRUDT1E UNEXPECTED DATA LENGTH OF ll

Explanation: Hiperstation for Mainframe Servers found a two-byte length field in the APPC data stream that has an invalid value of ll.

User Response: The length field that precedes all application data in an APPC data stream must have a value of two or greater. Hiperstation for Mainframe Servers found either a length of zero or one. A length of one is valid if the following data was a valid Presentation Services (PS) data stream, but a PS data stream was not found.

E62PRUDT2E UNEXPECTED GDS ID(gggg)

Explanation: Hiperstation for Mainframe Servers found an invalid or unrecognized Generalized Data Stream (GDS) ID in the APPC data stream for a mapped conversation.

User Response: Ensure that the APPC application is sending valid APPC data streams. GDS IDs in data for a mapped APPC conversation must be:

• ‘12F1’x (null data)• ‘12F2’x (user control data)• ‘12F3’x (map name)• ‘12F4’x (error data)• ‘12FF’x (application data).

E62PRUDT3E EXPECTED ERROR LOG DATA BUT SAW GDS ID(gggg) INSTEAD

Explanation: Hiperstation for Mainframe Servers has first seen a Function Management Header type 7 (FMH7) that indicated APPC error log data was forthcoming and then saw other data rather than the error log data.

User Response: Ensure that the APPC application is sending valid APPC data streams. Ensure that error log data is sent after an FMH7.

E62WLOGEE62WLOGE1E UNRECOGNIZED CONVERSATION LOG ITEM (tt)

Explanation: Hiperstation for Mainframe Servers found an internal error while producing a conversation log.

User Response: Contact Compuware Customer Support to help resolve this error.

ECVSAMECVSAMIO01 REQUEST=ccccc, RETURN CODE=xxx, FDBK=yy

Explanation: An error occurred while processing the specified VSAM request. If you receive the following message, the request file was never initialized:

REQUEST=GET, RETURN CODE=008, FDBK=74

User Response: See IBM’s Macro Instructions for VSAM Datasets for an explanation of the return code (xxx) and feedback code (yy) for the request, or call Compuware Customer Support.

ECVSAMIO02 REQUEST=ccccc, RETURN CODE=xxx, ACB ERROR=yy

Explanation: An error occurred while processing the specified VSAM request.

User Response: See IBM’s Macro Instructions for VSAM Datasets for an explanation of the return code (xxx) and reason code (yy) for the request, or call Compuware Customer Support.

Page 50: Hiperstation Messages and Codes

2-36 Hiperstation Messages and Codes

EHS3COPYEHS3COPY-0001I SCANNING RECORD: CONTROL OR COPY STATEMENT

Explanation: Displays user supplied statement.

User Response: Informational message. No user action necessary.

EHS3COPY-0002E STATEMENT #nnnn MUST BEGIN WITH 'CONTROL' OR 'COPY', BEGINS WITH: xxxxxxxx

Explanation: User supplied statement is not CONTROL or COPY statement.

User Response: Correct statement supplied in SYSIN datastream and re-run.

EHS3COPY-0003E UNABLE TO OPEN SYSIN

Explanation: Cannot open SYSIN file.

User Response: Correct the error and re-run.

EHS3COPY-0004E STATEMENT #nnnn INVALID PARAMETER WITHIN 'CONTROL' STATEMENT

Explanation: Invalid parameter on CONTROL statement.

User Response: Correct the statement and re-run.

EHS3COPY-0005E 'EXIT' MUST BE A VALID PROGRAM NAME OR NO

Explanation: Invalid program specified in EXIT parameter.

User Response: Correct the error and re-run.

EHS3COPY-0006E 'COPY' MUST BE EITHER YES OR NO

Explanation: COPY parameter in CONTROL statement must be YES or NO.

User Response: Correct the error and re-run.

EHS3COPY-0007I MAIN WORK AREA OBTAINED. SIZE = nnnn.

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0008E STATEMENT #nnnn INVALID PARAMETER WITHIN 'COPY' STATEMENT.

Explanation: Invalid parameter on COPY statement.

User Response: Correct the parameter and re-run.

EHS3COPY-0009E SYNTAX ERROR WITHIN xxxxxxxx PARAMETER

Explanation: Invalid value specified on parameter xxxxxxxx.

User Response: Correct the value and re-run.

EHS3COPY-0010E PROGRAM LOAD FAILURE - PROCESSING WILL BE TERMINATED.

Explanation: Cannot load program specified on EXIT parameter in CONTROL statement.

User Response: Correct the error and re-run.

EHS3COPY-0012E TIMEZONE PAREMETER MSUST BE BETWEEN -24 AND 24

Explanation: TIMEZONE must be between -24 and 24.

User Response: Correct the value and re-run.

EHS3COPY-0013E REPOS REC INVALID AND DISCARDED (RC=32) AT AROUND REPOS SEG= nn REC = nn.

Explanation: Invalid repository record. RC could be either 32 or 36.

User Response: If user modified the repository record, it could be damaged. Contact Compuware Customer Support.

Page 51: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-37

EHS3COPY-0014E MULTIPLE CONTROL STATEMENTS SPECIFIED. TERMINATING.

Explanation: More than on CONTROL statement specified.

User Response: Correct the error and re-run.

EHS3COPY-0015E COPY STATEMENT #nnnn BYPASSED DUE TO ERROR NOTED ABOVE

Explanation: Informational message

User Response: Check the error noted above and re-run.

EHS3COPY-0016E CONTROL STATEMENT #nnnn BYPASSED DUE TO ERROR NOTED ABOVE

Explanation: Informational message

User Response: Check the error noted above and re-run.

EHS3COPY-0017I CONTROL STATEMENT #nnnn ACCEPTED

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0018I COPY STATEMENT #nnnn ACCEPTED

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0019I COPY STATEMENT #nnnn PARSING COMPLETED

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0020I CONTROL STATEMENT #nnnn PARSING COMPLETED

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0021E USER EXIT PROGRAM RETURNED NON ZERO RC = rc.

Explanation: Informational message. If return code is not zero, program terminates.

User Response: Check why the non-zero return code occurred, correct the error, and re-run.

EHS3COPY-0022I REPOSITORY FILE : REC-IN = nn REC-OUT = nn

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0023I GLOBAL RECORDS IN : 3270 = nn LU62 = nn TCP/MQ = nn TOTAL = nn

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0024I GLOBAL RECORDS OUT: 3270 = nn LU62 = nn TCP/MQ = nn TOTAL = nn

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0025I TOTAL USER EXIT CALLS = nn

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0026E FILE OPEN ERROR - DDN: INDD

Explanation: Cannot open the file specified by the indicated DD statement (DDN).

User Response: Ensure that the DD name in the JCL matches the DDN shown in the error message and that the specified dataset is a sequential dataset.

Page 52: Hiperstation Messages and Codes

2-38 Hiperstation Messages and Codes

EHS3COPY-0028E EXPECTED CONTINUATION FOR CONTROL CARD=CONTROL OR COPY STATEMENT NOT FOUND.

Explanation: The last character of the last statement was ‘-’ (a continuation character).

User Response: Correct the error and re-run.

EHS3COPY-0031E EHS3COPY TERMINATED WITH ERRORS.

Explanation: Informational message.

User Response: Correct the error and re-run.

EHS3COPY-0032E MAXIMUM RETURN CODE=rc

Explanation: Informational message - displays maximum return code.

User Response: None. If return code is not zero, the job had an error.

EHS3COPY-0033I EHS3COPY COMPLETED SUCCESSFULLY.

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0034I READING CONTROL CARDS(SYSIN)

Explanation: Informational message.

User Response: No user action necessary.

EHS3COPY-0035E INVALID TOKEN FOUND: xxxxxxxx

Explanation: Unknown parameter specified in CONTROL or COPY statement.

User Response: Correct the parameter and re-run.

EHS3COPY-0036E INVALID STATEMENT FOUND: xxxxxxxx

Explanation: Value of a parameter on the CONTROL or COPY statement is incorrect.

User Response: Correct the error and re-run.

EHS3COPY-0037E NO CONTROL STATEMENT. TERMINATING.

Explanation: SYSIN file has no CONTROL statement.

User Response: Add CONTROL statement and re-run.

EHS3COPY-0039E NO OF COPY STATEMENTS EXCEEDS 999. TERMINATING.

Explanation: Number of COPY statements exceeds more than allowed.

User Response: Correct the error and re-run.

EHS3COPY-0040E PARTIAL REPOS SEGMENT(S) BEFORE THE EOF IGNORED.

Explanation: Repository file did not have last segment record at the end.

User Response: Concatenate previous segment repository file and re-run.

EHS3COPY-0041E MISSING BEGINNING SEGMENT RECORD AT repo_rec=n

Explanation: Repository file did not have first segment at the beginning.

User Response: Concatenate previous segment repository file and re-run.

EHS3COPY-0042E MISSING ENDING SEGMENT RECORD AT repo_rec=nnnnn

Explanation: Repository file did not have last segment record in the middle of the file.

User Response: Repository file was not created properly. Recovery impossible.

EHS3COPY-0043E nn REPOS RECORD(S) HAVE BEEN DISCARDED

Explanation: Informational message.

User Response: Correct the error and re-run.

Page 53: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-39

EHSBEHSB000I ALL PORTS ATTACHED

Explanation: All LUs have been initiated.

EHSB001W EXPECTED CONTINUATION NOT FOUND

Explanation: The last statement in the conversation log indicated a continuation but ‘end of file’ was found.

User Response: Remove the continuation indication from the last statement or provide the continued statements.

EHSB002E DUE TO THE ABOVE ERRORS, THE ABOVE STATEMENT HAS BEEN IGNORED

Explanation: One or more errors have been detected for the above statement and it is impossible to accept it. This statement is ignored.

User Response: Remove or correct the invalid statement.

EHSB003I PORT TERMINATED

Explanation: The port controlling the LU2 or LU6.2 playback has ended.

EHSB004I GROUP xxxx TERMINATED

Explanation: All ports for the xxxx group have completed.

EHSB005E ATTACH FAILED FOR PORT TASK, CALL PRODUCT SUPPORT

Explanation: A port that was to control an LU2 or LU6.2 playback could not be started.

User Response: Call Compuware Customer Support for an explanation.

EHSB006I PORT TASK STARTED

Explanation: A port that will control an LU2 or LU6.2 playback has started.

EHSB007I SKIPPING TO NEXT VALID KEYWORD OR STATEMENT

Explanation: A statement’s keyword was found to be invalid. This keyword is ignored and the next keyword or statement is processed.

User Response: Correct the statement in the conversation log.

EHSB008E INVALID KEYWORD ON SETUP STATEMENT

Explanation: An internal error has occurred.

User Response: Call Compuware Customer Support for an explanation.

EHSB009I REQUESTS SYNCHRONIZATION

Explanation: The port has requested synchronization with other ports.

EHSB010I NEW SCRIPT STARTED

Explanation: A new script has been started.

EHSB011I BEGINNING SCRIPT xxxxxxxx PLAY yyyyyyyy

Explanation: The script xxxxxxxx has started. If this is an LU6.2 script, the PLAY indicates whether INBOUND or OUTBOUND will be sent to the partner.

EHSB012E STATEMENT(xxxxxxxx) INVALID KEYWORD(xxxxxxxx) - KEYWORD IGNORED

Explanation: The keyword xxxxxxxx is not valid for the statement, or the JCL for an unattended mode of a script contains numbers in columns 73-80.

User Response: Correct or remove the keyword and resubmit the playback

EHSB013E ATTACHED FAILED FOR AL62 TASK, CALL PRODUCT SUPPORT

Explanation: The AL62 subtask was unable to start.

Page 54: Hiperstation Messages and Codes

2-40 Hiperstation Messages and Codes

User Response: Call Compuware Customer Support for an explanation.

EHSB014E STATEMENT(xxxxxxxx) KEYWORD(xxxxxxxx), VALID VALUE - KEYWORD IGNORED

Explanation: The keyword xxxxxxxx value is not valid.

User Response: Correct the keyword value or remove the keyword and its value and resubmit the playback.

EHSB015I LU6.2 CONTROL TASK STARTED

Explanation: The AL62 subtask was started.

EHSB016I READING INPUT CONTROL STATEMENTS

Explanation: The input control statements are about to be read from SYSIN.

EHSB017E INVALID STATEMENT TYPE(xxxxxxxx) DETECTED

Explanation: The operation xxxxxxxx on the previous statement is not valid.

User Response: Correct the operation and resubmit the playback.

EHSB018I INPUT CONTROL STATEMENT SCAN COMPLETE

Explanation: All input control statements have been processed.

EHSB019I COMPLETED SCRIPT xxxxxxxx

Explanation: The script xxxxxxxx has finished.

EHSB020I ALL PORTS TERMINATED

Explanation: All ports have been stopped.

EHSB022I ELAPSED TIME mm:ss.tht TRANSACTIONS: tttttt PER SECOND: nnnn

Explanation: Unattended playback has completed. The elapsed time between the earliest and latest session is shown by mm:ss.tht, the number of transactions executed was tttttt, and the rate per second was nnnn. A transaction to Hiperstation is defined as the user’s input followed by the domain destination’s output.

EHSB021I SYNCHRONIZATION RESTART

Explanation: A port requesting synchronization has been started.

EHSB023I INPUT STATEMENT: xx--xx

Explanation: The xx-xx statement has been read from input.

EHSB024I BEING TERMINATED

Explanation: This message is issued each time the GROUP statement cycles through a REPEAT variable.

EHSB025I CONTINUED STATEMENT: xx--xx

Explanation: The xx-xx statement has been determined to be a continuation of the previous statement.

User Response: If this is not true, then remove the continuation character from the previous statement.

EHSB026I ‘ACTUAL’ SCRIPT HAS NO INPUT - COMPARE NOT DONE

Explanation: User may have inadvertently entered playback mode when meaning to do a compare.

User Response: Remove control card from unattended job stream.

EHSB027I TASK ACTIVATION TIME - MINIMUM: mm:ss.ddd AVERAGE: mm.ss.ddd MAXIMUM: mm.ss.ddd

Explanation: This is the minimum, average and maximum time it takes to activate the subtasks controlling each port. These values are an indication of the load on the MVS system. These values should all be under 1 second.

Page 55: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-41

User Response: If the average is greater than 3 seconds, the region may need to be dispatched at a higher priority, or an occurring resource contention should be reduced or eliminated.

EHSB028I REXX PROCESSING DISABLED VIA REXXOFF

Explanation: The CONTROL statement has set the REXXOFF keyword.

User Response: If REXX processing is needed, remove this keyword. If REXX processing is not required, use the REXXOFF keyword to reduce the potential for considerable resource utilization.

EHSB029I SCRIPT CACHING FACILITY DISABLED VIA CACHEOFF

Explanation: The CONTROL statement has set the CACHEOFF keyword.

User Response: If caching is needed, remove this keyword. Caching improves script processing by loading in-use scripts into memory to reduce I/O.

EHSB030I MAXIMUM CONCURRENT ACTIVE TASKS: NNNNN

Explanation: The is the number of tasks active at any one time.

EHSB031E NO TERMINALS FOUND TO REPLAY

Explanation: Either because of direct omission of GROUP, ALLOCATE, or ACCEPT statements, or because of errors found with these statements, no terminals exist to perform the playback.

User Response: Examine the conversation log and provide the necessary GROUP, ALLOCATE, or ACCEPT statements. Or, correct the ones with errors.

EHSB033I AVERAGE TRANSACTION RESPONSE TIME: mm:ss.tht (MM:SS.THT)

Explanation: Unattended playback has completed. The average transaction response time is shown by mm:ss.tht.

EHSB034I SCRIPT CACHING STORAGE UTILIZATION -- <16M:nnnnnnnn >16M:nnnnnnnn DSPC:nnnnnnnn

Explanation: This message shows how much storage was used for script CACHING. <16M is for below the line storage (usually DBCs); >16M is for above the line storage (control blocks/buffers); and DSPC is for dataspace usage.

EHSB035E <cmd> failed: DD(dddddddd) SCRIPT(ssssssss) - <text>

Explanation: The STOW or WRITE macro failed. If the <cmd> is WRITE, <text> is an error message. If the <cmd> is STOW, <text> contains the reason and return codes for the STOW macro.

User Response: Correct the error and rerun the job.

EHSB036E SCRIPT(ssssssss) created in DD(dddddddd)

Explanation: The script member (ssssssss) was written to DD(dddddddd).

EHSB037E GROUP STATEMENT(S) PRECEDED COMPARE STATEMENT

Explanation: The COMPARE statement must be before the first GROUP statement.

User Response: Correct and rerun.

EHSB038E COMPARE INCOMPATIBLE WITH THIS STATEMENT

Explanation: Either an ALLOCATE or an ACCEPT statement has been found. These statements cannot be used during an unattended comparison.

User Response: Remove those statements and rerun.

EHSB039I KEYWORD(………) IGNORED - THIS IS A COMPARE

Explanation: Informational message. The execution of EHSBATCH will proceed, but the keyword mentioned in the message will be ignored. Keywords that are ignored include TERM (when the value is greater than one), LOGD, DSYNCH, ALLSYNCH, TIMESYNC, THOPT, THPCT, THINK, REPEAT, and VTAMTRCE.

Page 56: Hiperstation Messages and Codes

2-42 Hiperstation Messages and Codes

EHSB040I KEYWORD(xxxxxxxx) IGNORED - DUBBING NOT ACTIVE

Explanation: The DUB keyword was not specified on the CONTROL or GROUP statement. Since dubbing was not activated, Hiperstation ignores dubbing keywords DUBMEM and NODUB.

System Action: EHSBATCH proceeds.

User Response: If you need to dub the script, add the DUB keyword to the CONTROL or GROUP statement and run the playback again.

EHSB041E NO CLOSING QUOTE FOUND

Explanation: The statement has been continued or ended without having matched quotes. Quoted text cannot be continued onto the next line — both the beginning and ending quote must be on the same statement line.

User Response: Correct the quote omission. If the text is too long to be contained on one line, the concatenation operation can be used to break up the text.

EHSB042E UNMATCHED OR MISPLACED PARENTHESIS FOUND

Explanation: The statement end has been found but there are too many opening or closing parentheses.

User Response: Correct the unbalanced parentheses.

EHSB043E CONCATENATION NOTATION ERROR

Explanation: The statement contains at least one vertical bar ( | ) character outside quoted text. However, it is not paired with another or there are too many together.

User Response: Correct the notation error. The concatenation operation is two bars (||).

EHSB044E NO GROUP/ALLOCATE/ACCEPT BEFORE SCRIPT STATEMENT

Explanation: A SCRIPT statement was found but no previous GROUP, ALLOCATE, or ACCEPT statement was found.

User Response: Provide the GROUP, ALLOCATE, or ACCEPT statement or remove the SCRIPT statement.

EHSB045I CPU TIME PROCESSING TRANSACTIONS: mm:ss.tht (MM:SS.THT)

Explanation: Unattended playback has completed. The amount of CPU time used by Hiperstation to feed the transactions to the domain destination is shown by mm:ss.tht.

Note: This is NOT the amount of CPU used by the domain destination.

EHSB046I TIME SYNC DISPATCH FOR INPUT WITH DATE/TIME:

Explanation: The script has been dispatched after waiting for synchronization with one or more other scripts.

EHSB047I PREVIOUS STATEMENT REJECTED, SKIPPING TO NEXT STATEMENT

Explanation: An invalid statement has been found. This statement will be ignored and the next will be verified.

User Response: Correct or remove the incorrect statement.

EHSB048I DUE TO THE ABOVE ERRORS(S) OR WARNING(S), THE DESIRED EHSB049I RESULTS MAY NOT BE ACHIEVABLE

Explanation: Errors have been found with the conversation log statements. Since those statements or keywords that are not understood are ignored, the resulting accepted statements and their keywords may not be sufficient to create the playback exactly as intended.

User Response: Examine the statements and keywords in error. Determine if they will affect the playback. If they will have a negative affect, correct the errors.

EHSB050E TERM OR REPEAT COUNT MUST BE 1 FOR DUBBING

Explanation: When dubbing is active, the terminal or repeat count cannot exceed one.

System Action: Playback terminates.

Page 57: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-43

User Response: Set the TERM and/or REPEAT values on the CONTROL or GROUP statements to one and run the playback again.

EHSB051E Script(xxxxxxxx) is a duplicate dubbing member

Explanation: Hiperstation found that a script already exists with the indicated name.

User Response: Change the name of the dubbing script, or enter (R) next to the dubbing script name.

EHSB052E CONCATENATION OPERATION PLACEMENT ERROR

Explanation: The concatenation operation can be performed only within the parenthetical keyword value. If this operation appears outside the parentheses, it is a placement error.

User Response: Examine the concatenation operation placement and correct.

EHSB053E NESTED QUOTES NOT PERMITTED DURING CONCATENATION

Explanation: The concatenation operation is used to join together quoted text. However, the quoted text contained additional quote characters. This is not allowed. If these quotes are needed, use hex notation to express them.

User Response: Examine the quoted text and remove the inside quotes or express the quoted text in hex notation.

EHSB054I START SYNCHRONIZATION AND/OR DELAY REQUESTED

Explanation: The STARTDLY or LOGD keyword has been found and the starting of the port has been delayed.

EHSB055I APP PROFILING ETRMMOPL ERROR. PORT xxxx

Explanation: Application profiling detected an internal error.

User Response: Contact Compuware Customer Support.

EHSB056W SCRIPT (xxxxxxxx) NOT FOUND

Explanation: The requested script was not found during Hiperstation playback initialization. Processing continues.

User Response: Correct the script (xxxxxxxx) statement or ensure that the script is a member in the dataset referenced by the SYSLIB DD statement.

EHSB057E DDNAME(xxxxxxxx) SCRIPT(xxxxxxxx) IN USE BY ANOTHER JOB

Explanation: Hiperstation found that the chosen script is in use by another Hiperstation online user or batch job.

User Response: Change the name of the dubbing script or wait until the job completes.

EHSB058E DDNAME(xxxxxxxx) OPEN FAILED

Explanation: The open failed for the chosen DDNAME.

User Response: Correct the DDNAME and/or control statements and rerun the job.

EHSB059E (xxxxxxxx) KEYWORD(xxxxxxxx), NOT VALID FOR LU2 - REPLAY TO BE TERMINATED

Explanation: The indicated xxxxxxxx keyword is not valid for an LU2 script. The playback will be terminated.

User Response: Correct or remove the keyword and retry the playback.

EHSB060I PREMATURE COMPARE TERMINATION, UNEQUAL SCRIPTS

Explanation: This informational message occurs when two scripts with a different number of output screens are being processed by unattended comparison (for example, one script reaches end of file (EOF) while the other script still has screens left to compare).

User Response: Examine the two scripts being compared to determine if this early termination was expected.

Page 58: Hiperstation Messages and Codes

2-44 Hiperstation Messages and Codes

EHSB061E FMH-5 RECEIVED BUT NO MATCH FOUND FOR THE FOLLOWING --

Explanation: The remote (sending) network ID and LU name along with the local LU name, logmode, and TP name appear with this message. An FMH5 header was received by the local LU, but no matching accept statement was found.

User Response: Ensure that:

• All ACCEPT statements contain the correct sender, receiver, logmode, and TP name. All of these fields are mandatory on ACCEPT statements.

• A sufficient NOFMH5TO value is listed on the CONTROl statement. This error message results if any FMH5 headers are received after the expiration of this time.

• You have sufficient ACCEPT statements to receive all of the expected FMH5 headers to be received for a given local LU name.

EHSB061I FMH-5 RECEIVED BUT NO MATCH FOR THE FOLLOWING --

EHSB062I SENDER(net): netname SENDER(LU): luname RECEIVER: name LOGMODE: mode

EHSB064I TPNAME(CHR(01-64)): xxx…xx

EHSB065I TPNAME(HEX(01-32)): xxx…xx

EHSB066I TPNAME(HEX(33-64)): xxx…xx

Explanation: An FMH5 has been received but using the SENDER, RECEIVER, LOGMODE, and TPNAME no match could be found for them as ACCEPT arguments. The matching criterion follows. The TPNAME is shown in character (CHR) and in hexadecimal (HEX). The character form has been “translated” to show only printable characters. All others have been replaced with the period character (.).

User Response: If this data indicates an FMH5 that should be handled by Hiperstation, then matching ACCEPT data should be provided in the conversation log to activate the appropriate scripts.

EHSB070I PORT xxxx ATTACHED

Explanation: The indicated port subtask has been attached.

EHSB071I GROUP xxxx WAITING FOR TIME RELEASE

Explanation: The indicated group is waiting until its time to release has expired.

EHSB072I PORT xxxx WAITING FOR FMH-5

Explanation: The indicated port is waiting until the correct FMH5 is received.

EHSB074I GROUP xxxx REMOVED FROM PROCESSING BECAUSE TPNAME IS ‘06F1’X

Explanation: The designated group has a TPNAME of ‘06F1’x. This cannot be played back due to VTAM restrictions. The group has been removed from processing.

User Response: To prevent this message in future playbacks, remove the designated group and its associated scripts from the conversation log.

EHSB075I GROUP xxxx REMOVED FROM PROCESSING BECAUSE IT HAS NO SCRIPT(S)

Explanation: The designated group has no associated scripts. The group has been removed from processing.

User Response: To prevent this message in future playbacks, remove the designated group from the conversation log.

EHSB077I READY FOR LU6.2 SLU COMMUNICATIONS

Explanation: Hiperstation for Mainframe Servers has reached the point when it is possible to receive an allocate from the partners. This message is issued to the system console.

User Response: Start any partners sending an allocate to Hiperstation for Mainframe Servers.

EHSB096E TOO MANY TIMESYNCHED GROUPS

Explanation: The playback job contains more than 8000 GROUPs, which exceeds the TIMSYNC parameter limit.

Page 59: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-45

User Response: Use fewer than 8000 GROUPs, or do not use the TIMESYNC parameter.

EHSB098I MAXIMUM SCRIPT RC=ssss, INTERNAL RC=iiii

Value ssss is the largest value set by a REXX RETURN or EXIT statement in any of the scripts executed during playback. Only a value set in the final script within a GROUP statement is used. Value iiii is the largest value set internally by Hiperstation to indicate an informational or error condition. The larger of ssss and iiii is returned as the MVS job step return code and is available for testing with the MVS JCL COND parameter. Both ssss and iiii are decimal values, not hexadecimal.The Hiperstation scripts you are playing back produce the ssss value, typically by issuing a RETURN or EXIT statement. Only numeric values from 0 through 4095 should be supplied on the RETURN or EXIT statement for use as a job step return code. All other values have their last 12 bits used. Scripts without a RETURN or EXIT statement produce an ssss value of 0. The ssss value can also be set if a script abnormally ends (ABENDs). For example, a script that caused an S0C4 abend produces an ssss value of 196 (x‘0C4’ = decimal 196).The iiii value is documented in Unattended Mode Return Codes.In addition to the EHSB098I message, Hiperstation writes status, error, and warning messages to SYSPRINT. If the playback job step returns a non-zero code, review the return code description provided in Table 2-1. Then review the warning and error messages to determine the cause of the problem.

Table 2-1. Hiperstation for VTAM Unattended Playback Return Codes

RC Description

0 All scripts ran successfully.

8 Occurs when the COPT option setting flags a mismatch and LOG or XLOG is specified.

12

Error: LU6.2 or LU2 unattended mode process contains exceptions at the record level. For example:

• One or more corresponding record lengths are not equal

• Sense data is not equal on one or more records

• Log data is not the same length for corresponding records.

16 Error: Invalid script statement found

20

Serious Error:

• Port could not be started because LU2 application is not valid or not active

• Port started, but could not be initialized

• REXX EXEC/script not found.

24 Serious Error: The first port to be started could not start — the unattended mode process is terminated. If other ports are started, unattended mode continues.

Page 60: Hiperstation Messages and Codes

2-46 Hiperstation Messages and Codes

Informational message. No user action necessary. For more information about unattended mode return codes, see the Hiperstation for VTAM User Guide in the chapter on unattended playback, dubbing, and comparison for 3270 and LU0 scripts.

EHSB100E DATASET NAME MISSING ON kkkkkkkk

Explanation: The kkkkkkkk keyword requires a dataset name or a SYSOUT class as the destination for “print” output. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: Supply a dataset name (more than 1 character) with an optional member name, or a SYSOUT class (exactly 1 character) as the value of the kkkkkkkk keyword.

EHSB101E DATASET NAME TOO LONG ON kkkkkkkk

Explanation: The dataset name supplied on the kkkkkkkk keyword is not valid because it consists of more than 44 characters. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: Supply a dataset name consisting of 2 through 44 characters.

EHSB102E MANY WILDCARDS ON kkkkkkkk VALUE (7 MAX)

Explanation: The dataset or member name supplied on the kkkkkkkk keyword contains more than 7 wildcard characters (the wildcard characters are * and ?). The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

Wildcard characters identify the point in a dataset and/or member name where a PORT or GROUP number will be substituted. Because a member name and a segment (the characters between dots) in a dataset name can be at most eight characters and because the first character cannot be a number, only 7 positions are available for wildcard substitution.

28

SEVERE ERROR: Port subtask could not be started.

• SYSPRINT could not be opened or error occurred processing SYSPRINT

• SYSIN could not be opened or error occurred processing SYSIN

• SYSCNTL could not be opened or error occurred processing SYSCNTL

• User failed security authorization

• Either LU2 or LU6.2 pool names could not be built from the provided prefix and suffix values.

• Product is not licensed for LU6.2 (APPC) unattended mode processing

• LU6.2 is not supported for LU6.2 scripts

• Trace could not be initialized

• No terminals found to be played back

• VTAM initialization error.

• A syntax error exists on the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, or TRACE keywords on the CONTROL, GROUP, ALLOCATE, or COMPARE statements.

32 SERIOUS ERROR: A print file is full or could not be processed. The print files are the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, and TRACE files.

40 SEVERE ERROR: Hiperstation is about to expire or has expired. Contact Hiperstation Customer Support for a date extension and new release availability information.

44

SECURITY ERROR: Hiperstation detected an unauthorized default parameter table. Contact your systems programmer.

The most common cause of the RC=44 is a non-authorized SQQFLOAD.

Table 2-1. Hiperstation for VTAM Unattended Playback Return Codes

RC Description

Page 61: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-47

User Response: Supply at most 7 wildcard characters on a dataset name and on a member name.

EHSB103E MIX OF * AND ? NOT ALLOWED ON kkkkkkkk

Explanation: Both ‘*’ and ‘?’ have been supplied, more than one ‘*’ has been supplied, or several ‘?’ have been supplied separated by other characters. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

Wildcard characters used in dataset and member names must follow these rules:

– If an ‘*’ is supplied, it can be used only once.

– If an ‘*’ is supplied, a ‘?’ cannot also be used.

– Several ‘?’ can be supplied, but they cannot be separated from each other by any other characters.

– A wildcard cannot appear as the first character in a dataset segment (the part between the dots) or as the first character in a member name.

– These rules apply independently to dataset and member names, (for example, wildcards can appear in either, neither, or both dataset and member names.

User Response: Remove one or more of the incorrect wildcard characters.

EHSB104E MAY NOT BE 1ST CHAR ON kkkkkkkk

Explanation: A wildcard cannot appear as the first character in a dataset segment (the part between the dots) or as the first character in a member name. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: Remove the wildcard character from the first position.

EHSB105E SEGMENT TOO LONG ON kkkkkkkk

Explanation: A dataset segment (the part between the dots) can be at most eight characters long. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: Shorten the incorrect dataset segment.

EHSB106E MEMBER MUST BE IN PARENTHESES ON kkkkkkkk

Explanation: A value after a dataset name has been supplied but it is not enclosed in parentheses. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: If you want to supply a member name, enclose it in parentheses immediately after the dataset name.

EHSB107E MEMBER NAME TOO LONG ON kkkkkkkk

Explanation: A member name can be at most eight characters long. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: Shorten the incorrect member name.

EHSB108E DATASET NAME TOO LONG TO ADD SUFFIX ON kkkkkkkk

Explanation: A dataset name and no member or wildcards have been supplied and the dataset name is longer than 38 characters. Unattended playback needs room to add the ‘.P0000’ suffix to the dataset name. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, or AUTODOC.

User Response: Reduce the length of the dataset name you supply or use wildcards to identify where the PORT or GROUP number should be substituted.

EHSB109E WILDCARDS NOT ALLOWED ON TRACE

Explanation: The TRACE keyword value on the CONTROL statement cannot contain any wildcard characters because no PORT or GROUP number needs to be substituted into the name.

User Response: Remove any wildcards from the dataset and/or member name on the CONTROL TRACE keyword.

Page 62: Hiperstation Messages and Codes

2-48 Hiperstation Messages and Codes

EHSB110E MEMBER WHEN SYSOUT CLASS ON kkkkkkkk

Explanation: A member name has been supplied even though a SYSOUT class is in use. A value is interpreted as a SYSOUT class if it is exactly 1 character long. The value of kkkkkkkk can be JOURNAL, LOG, XLOG, RLOG, TRACE, AUTODOC, or SUMMARY.

User Response: If you want to supply a member name, you must also supply a dataset name. Either remove the member name or change the SYSOUT class to a dataset name.

EHSB111E (dddd), MEMBER(mmmm)

Explanation: An error has occurred with dataset dddd on keyword kkkkkkkk, possibly with a member name of mmmm. The error is listed in an earlier message for the same PORT and GROUP number.

User Response: Find the associated error message earlier in the message log and correct the problem that it describes. Look for an error message labeled with the same GROUP and PORT numbers as this message. The EHSB111E message simply identifies the keyword, dataset, and member that has the problem.

EHSB143E INVALID KEYWORD ON PAUSE STATEMENT

Explanation: During script processing, an invalid keyword was detected on a <PAUSE> or <WAIT> script tag.

User Response: Correct the script tag and playback the script again.

EHSB144I KEYWORD(xxxxxxxx) IGNORED - DUB MEMBER SPECIFIED AT GROUP LEVEL

Explanation: You specified a member name on both the DUB keyword on the GROUP statement and the DUBMEM keyword on the subsequent SCRIPT statements.

System Action: EHSBATCH proceeds, but ignores the keyword specified in the error message.

User Response: Either remove the member name from the DUB keyword on the GROUP statement or remove the DUBMEM keyword from the SCRIPT statements and run playback job again.

EHSB201E SYSPRINT DD STATEMENT FAILED TO OPEN, EXECUTION TERMINATED

Explanation: Unattended mode execution requires a SYSPRINT DD statement for messages.

User Response: Insert a SYSPRINT DD statement in your JCL and re-submit the job.

EHSB202E SYSIN DD STATEMENT NOT ALLOCATED, EXECUTION TERMINATED

Explanation: Unattended mode execution requires a SYSIN DD statement for control statements.

User Response: Insert a SYSIN DD statement in your JCL and re-submit the job. The SYSIN DD should reference control statements that instruct Hiperstation as to what to do.

EHSB203E SYSLIB DD STATEMENT NOT ALLOCATED, EXECUTION TERMINATED

Explanation: Unattended mode execution requires a SYSLIB DD statement for scripts.

User Response: Insert a SYSLIB DD statement in your JCL and re-submit the job. The SYSLIB DD should reference a PDS script dataset from which the script will be read.

EHSB900I HIPERSTATION UNATTENDED MODE - LEVEL vv.rr.mm

Explanation: This is the Hiperstation version information.

EHSB901I COPYRIGHT(C) 1994, 1999 COMPUWARE CORPORATION

EHSB902I UNPUBLISHED_RIGHTS RESERVED UNDER THE COPYRIGHT

EHSB903I LAWS OF THE UNITED STATES.

EHSB904I

Explanation: This copyright notice appears at the start of every batch listing.

EHSB910I REPLAY STARTING: xx/xx/xx at xx:xx:xx

Explanation: Date and time the playback function has started.

Page 63: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-49

EHSB912E SECURITY DENIED ACCESS TO THE UNATTENDED MODE FACILITY

Explanation: Your system security has rejected your use of the unattended mode function (unattended playback, dubbing, or comparison).

User Response: Contact your security administrator for an explanation or correction of this situation.

EHSB913E SECURITY DENIED ACCESS TO PLAY SCRIPTS AGAINST TPF xxxxxxxx

Explanation: Your system security has rejected your access to the domain destination named xxxxxxxx.

User Response: Contact your security administrator for an explanation or correction of this situation.

EHSB914E SECURITY DENIED ACCESS TO TRACE OPTION

Explanation: Your system security has rejected your access to the trace option.

User Response: Contact your security administrator for an explanation or correction of this situation.

EHSB997T CONVERSATION LOG CONTAINS LU6.2 STATEMENTS, BUT YOU ARE RUNNING UNDER THE CPI - REPLAY TERMINATED

Explanation: While running under the CPI, LU6.2 statements were found. LU6.2 is not supported under the CPI.

User Response: Remove the LU6.2 statements.

EHSB998T CONVERSATION LOG CONTAINS LU6.2 STATEMENTS, BUT YOU ARE NOT LICENSED FOR LU6.2 - REPLAY TERMINATED

Explanation: The conversation log contains LU6.2 statements but Hiperstation for Mainframe Servers is not licensed for it at your site.

User Response: Remove the LU6.2 statements and submit again. If your site is licensed for LU6.2 support, call Compuware Customer Support.

EHSCEHSC001 ALL EHSQUEUE ENTRIES CURRENTLY IN USE - TRY AGAIN, LATER

Explanation: File capture log message.

User Response: Try the activity at a later time.

EHSC002 TEMP STORAGE QUEUE ID ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC004 TEMP STORAGE QUEUE ITEM NOT FOUND

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC005 FILE NOT IN FCT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC006 VSAM ILLOGIC ERROR ENCOUNTERED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC007 INVALID REQUEST FOR FILE ENCOUNTERED

Explanation: File capture log message.

Page 64: Hiperstation Messages and Codes

2-50 Hiperstation Messages and Codes

User Response: Informational message. No user action necessary.

EHSC008 I/O ERROR ENCOUNTERED ON FILE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC009 NO SPACE IN FILE

Explanation: File capture log message.

User Response: Increase file space and rerun.

EHSC010 FILE IS NOT OPENED

Explanation: File capture log message.

User Response: Open file and rerun.

EHSC011 INVALID TEMP STORAGE REQUEST ERROR ENCOUNTERED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC012 TEMP STORAGE I/O ERROR ENCOUNTERED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC013 NO SPACE IN TEMP STORAGE

Explanation: File capture log message.

User Response: Increase size of temporary storage and rerun.

EHSC014 OPTIONS RECORD IS CURRENTLY IN USE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC015 FILE RECORDING LOCAL TASK DID NOT INITIATE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC016 ATTACH FAILED FOR FILE RECORDING LOCAL TASK

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC017 LOCAL TASK TERMINATED WITH AN UNKNOWN ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC018 LOCAL TASK COULD NOT READ REQUEST RECORD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC019 LOCAL TASK COULD NOT GET BUFFER SPACE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC020 EXIT PROGRAM NOT IN PPT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 65: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-51

EHSC021 INVALID EXIT ID

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC022 EXIT PROGRAM ALREADY ENABLED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC023 PROGRAM ALREADY ACTIVE FOR EXIT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC024 EXIT PROGRAM NOT ENABLED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC025 EXIT PROGRAM HAS NO WORK AREA

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC026 EXIT PROGRAM NOT ENABLED (DISABLE REQ)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC027 PROGRAM NOT ACTIVE FOR EXIT (DISABLE)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC028 EXIT INVOKED BY ANOTHER TASK

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC029 EXIT INTERFACE NOT ENABLED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC030 UNKNOWN EXIT ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC031 FILE RECORDING REQUEST LIMIT REACHED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC032 UNEXPECTED ERROR, EIBFN: X‘NNNN’, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC033 FILE FRONT ENDS COULD NOT BE LOADED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 66: Hiperstation Messages and Codes

2-52 Hiperstation Messages and Codes

EHSC034 DB2 INSTALLATION ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC035 DB2 INSUFFICIENT STORAGE TO INITIALIZE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC036 DB2 BACKGROUND TASK DID NOT START

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC037 DB2 CICS ATTACH FACILITY NOT ACTIVE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC038 DB2 STATEMENT LOAD IN PROGRESS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC039 FILE ERROR ENCOUNTERED ON: XXXXXXXX, ERR: XXXXXXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC040 FILE REROUTE HAS BEEN CANCELLED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC041 FILE REROUTE LOCAL TASK DID NOT INITIATE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC042 ATTACH FAILED FOR FILE REROUTE LOCAL TASK

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC043 LOCAL TASK COULD NOT READ CONTROL RECORD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC100 FILE RECORDING PDS= XXX PREFIX= YYY

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC101 FILE RECORDING ENDED RETURN CODE RRRR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC102 *WARNING* - DELETED/BROWSED RECS LOGGING TRANS FAILED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 67: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-53

EHSC103 *WARNING* - DELETED/BROWSED RECS LOGGING TRANS DID NOT COMPLETE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC104 *WARNING* - DELETED/BROWSED RECS LOGGING TRANS "POST" FAILED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC105 *WARNING* - DELETED/BROWSED RECS LOGGING TRANS ATTACH FAILED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC106 FILE RECORDING FILE ERROR, EIBRCODE: X‘NNNN’ FILE: XXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC107 FILE RECORDING UNEXPECTED ERROR, EIBFN: X‘NN’ EIBRCODE: X‘NNNN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC108 *WARNING* - FILE ARCHIVE IS FULL

Explanation: File capture log message.

User Response: Increase size of file archive and rerun.

EHSC109 *WARNING* - 257TH FILE LOST BECAUSE 256 IS MAX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC110 *WARNING* - 500,001ST RECORD LOST BECAUSE 500,000 IS MAX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC111 *WARNING* - THE REMOTE FILE INFORMATION TABLE HAS OVERFLOWED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC112 INFORMATION FOR REMOTE FILE XXX ON SYSID CCCC COULD NOT BE OBTAINED DUE TO:

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC113 TEMP STORAGE ERROR ENCOUNTERED, ERROR: NNN

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC114 *WARNING* - ONE OR MORE TD TRIGGERED OR IC STARTED TASKS WERE NOT RECORDED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC115 STOP UNSUCCESSFUL FOR REMOTE SYSID: SSSS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 68: Hiperstation Messages and Codes

2-54 Hiperstation Messages and Codes

EHSC116 REMOTE SYSTEM: SSSS FAILED TO STOP WITHIN THE ALLOTED TIME

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC117 FILE RECORDING START - SYSID STATUS FOLLOWS:

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC118 NO REMOTE SYSIDS DEFINED ON THIS SYSTEM (OR ALL WERE EXCLUDED)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC119 NO REMOTE FILE ACTIVITY WILL BE RECORDED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC120 COMMUNICATION ERROR WITH SYSID: SSSS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC121 REMOTE CONTROL TASK WOULD NOT START ON SYSID: SSSS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC122 INTERVAL CONTROL ERROR ENCOUNTERED, ERROR: XXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC123 DB2 IS NOT ACTIVE, DB2 ACTIVITY WILL NOT BE RECORDED IN THIS REGION

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC130 SQL ERROR ENCOUNTERED RETRIEVING DB2 CATALOG INFORMATION FOR TABLE: XXXXXXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC131 DB2 CATALOG INFORMATION WAS NOT FOUND FOR TABLE: XXXXXXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC135 ERROR ENCOUNTERED WRITING DB2 INFO RECORD, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC157 UNABLE TO OBTAIN STORAGE FOR HOST VARIABLES

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC160 UNABLE TO WRITE DB2 CALL RECORD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 69: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-55

EHSC161 UNABLE TO LOCATE DB2 STATEMENT FOR PLAN PPPP DBRM DDDD STMT SSSS SECT TTTT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC166 UNABLE TO OBTAIN TABLE INFO FOR TABLE XXX.XXXXXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC184 FILE CAPTURE LIMIT EXCEEDED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC200 FILE RECORDING REMOTE TASK STARTING ON SYSID: CCCC, ORIGINATING SYSID: XXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC201 FILE RECORDING REMOTE TASK ENDING RETURN CODE: RRRR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC204 REMOTE TASK COULD NOT GET BUFFER SPACE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC205 START ERROR ENCOUNTERED SENDING TERMINATION STATS, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC206 ALLOCATE SESSION TO ORIGINATING SYSTEM FAILED, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC207 ALLOCATE SESSION TO ORIGINATING SYSTEM TIMED OUT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC208 SEND TO ORIGINATION SYSTEM FAILED, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC209 CANNOT CHECK BUFFER SEND/RECEIVE COUNTS, ORIGINATION SYSTEM UNAVAILABLE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC210 START ERROR ENCOUNTERED FOR FILE INFO PROGRAM, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC211 * LOGIC ERROR * BUFFER RECEIVE COUNT > SEND COUNT

Explanation: File capture log message.

Page 70: Hiperstation Messages and Codes

2-56 Hiperstation Messages and Codes

User Response: Informational message. No user action necessary.

EHSC212 BUFFER COUNT MISMATCH - SENT: XXX, RECEIVED: YYY

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC230 VSAM STATEMENT DATASET BUILD ENDED NORMALLY

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC231 VSAM STATEMENT DATASET BUILD TERMINATED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC232 TEMP STG Q ERROR (EIBRESP X‘NN’)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC233 DBRM(XXXXXXXX) STMT = 0 FOUND - RESULTS MAY VARY

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC236 CANNOT OPEN DB2 SYSTEM TABLES

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC237 VSAM READ ERROR (EIBRESP X‘NN’)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC240 DB2 CALL ATTACH FACILITY IS NOT ACTIVE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC241 WAITING FOR DB2 CALL ATTACH FACILITY TO START

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC246 XXX,XXX,XXX INVALID STATEMENTS DROPPED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC267 FILE ERROR ENCOUNTERED WRITING INFORMATION RECORD, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC285 PLAN PPPPPPPP, DBRM DDDDDDDD, STATEMENT SSSSS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC286 VSAM WRITE ERROR (EIBRESP X‘NN’)

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 71: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-57

EHSC287 EHSD2STL MAY NOT BE ENTERED VIA A TRANID

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC289 XXX,XXX,XXX STATEMENTS PROCESSED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC291 NO VALID PLAN, DBRM AND STATEMENT AT THIS POINT

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC292 CANNOT OBTAIN WRITE AUTHORITY FOR THE STATEMENT FILE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC293 CANNOT OBTAIN READ AUTHORITY FOR THE STATEMENT FILE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC294 VSAM DELETE ERROR (EIBRESP X‘NN’)

EHSC295 FULL LOAD IS CURRENTLY EXECUTING

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC296 XXX,XXX,XXX DBRMS PROCESSED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC298 LOAD COMPLETE FOR PLAN PPPPPPPP DBRM DDDDDDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC300 UNABLE TO CREATE INFORMATION RECORD FOR FILE NNNN DUE TO:

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC301 FILE ERROR ENCOUNTERED WRITING INFORMATION RECORD, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC302 UNKNOWN DATA SHIPPED TO EHSFMBFR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC303 ABEND RECOVERY HAS BEEN ENTERED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC304 ERROR DURING RECEIVE REQUEST, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 72: Hiperstation Messages and Codes

2-58 Hiperstation Messages and Codes

EHSC305 ERROR DURING CONVERSE REQUEST, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC307 NEXT FUNCTION NOT SPECIFIED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC321 CANNOT BE EXECUTED FROM A TERMINAL

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC359 DYNAMIC STATEMENT LOAD DISABLED - DB2 CAPTURE TERMINATING

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC364 GETMAIN FAILED IN EHSD2STG

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC365 ERROR ENCOUNTERED WRITING DB2 TABLE NAME RECORD, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC366 STATEMENT REQUEST QUEUE ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC367 CURSOR TABLE ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC368 UNABLE TO OBTAIN ALL STMT RECORD SEGMENTS, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC369 ERROR ENCOUNTERED READING DB2 STMT RECORDS, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC370 ERROR ENCOUNTERED READING DB2 TABLE INFORMATION RECORDS, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC371 ERROR ENCOUNTERED WRITING DB2 TABLE INFORMATION RECORDS, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC372 INVALID STATEMENT REQUEST

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 73: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-59

EHSC373 SQL ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC375 STATEMENT LOAD WARNING: XXXXXXXXXXXXXXXX

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC376 ABEND DETECTED - DB2 RECORDING TERMINATING

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC402 *WARNING* FILE TABLE OVERFLOW, XXX FROM SYSID CCCC WILL BE LOST

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC403 TERMINATTION NOTIFY FOR REMOTE SYSTEM: CCCC HAS FAILED

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC411 COMMUNICATION ERROR ENCOUNTERED WITH SYSID: CCCC

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC424 PARSE ERROR. RETURN CODE XXXX FOR STMT # NNNN IN DBRM DDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC425 ERROR IN SQL SQUISH. RETURN CODE IS XXXX FOR STATEMENT NUMBER NNNN IN DBRM DDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC445 UNABLE TO FIND STATEMENT NUMBER NNNNN IN DBRM DDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC446 SQL STATEMENT CONTROL BLOCK LOCATE ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC447 SQL STATEMENT CONTROL BLOCK CREATE ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC448 GETMAIN ERROR BUILDING STATEMENT TABLES

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC449 ERROR EXTRACTING TABLE NAME

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

Page 74: Hiperstation Messages and Codes

2-60 Hiperstation Messages and Codes

EHSC450 GETMAIN ERROR SAVING STATEMENTS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC451 TABLE NAME ADD ERROR

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC452 DBRM TIMESTAMP IS LATER THAN LOAD MODULE TIMESTAMP FOR PLAN PPPPPP DBRM DDDDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC453 LOAD MODULE TIMESTAMP IS LATER THAN DBRM TIMESTAMP FOR PLAN PPPPPP DBRM DDDDDD

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC464 ERROR WRITING DB2 STATEMENT RECORDS

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC467 ERROR WRITING TS QUEUE FOR DB2 CATALOG INFORMATION, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC468 ERROR STARTING DB2 CATALOG INFORMATION TASK, EIBRCODE: X‘NN’

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC469 GETMAIN ERROR SAVING COLUMN INFO

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC498 RESOLUTION TIMEOUT - DATA MAY BE MISSING FOR TABLE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC499 WAITING FOR TABLE INFORMATION COLLECTION TO COMPLETE

Explanation: File capture log message.

User Response: Informational message. No user action necessary.

EHSC500E BACKOUT FAILED, FILE=xxxxxxxx SEQ=nnnnnnnn

Explanation: File backout processing; a record on the CICS archive file which should exist was not found.

User Response: Save (IDCAMS backup) the archive file and notify Compuware Customer Support.

EHSC501E BACKOUT CANNOT FIND A RECORD KEY, FILE=xxxxxxxx SEQ=nnnnnnnn

Explanation: File backout processing; a record on the CICS archive file which contains data to be acted upon has no RID (Record Identification) data.

User Response: Save (IDCAMS backup) the archive file and notify Compuware Customer Support.

Page 75: Hiperstation Messages and Codes

Hiperstation Messages: ARCHV through EHSC 2-61

EHSC502E BACKOUT INVALID OPERATION, FILE=xxxxxxxx SEQ=nnnnnnnn

Explanation: File backout processing; a record on the CICS archive file which contains data to be acted upon has no valid action (DELETE, WRITE, REWRITE).

User Response: Save (IDCAMS backup) the archive file and notify Compuware Customer Support.

EHSC503E BACKOUT FAILED, FILE=xxxxxxxx SEQ=xxxxxxxx EIBRCODE=xxxxxxxxxx

Explanation: File backout processing error.

User Response: Save (IDCAMS backup) the archive file and notify Compuware Customer Support. Look up the EIBRCODE for a description of this error.

Page 76: Hiperstation Messages and Codes

2-62 Hiperstation Messages and Codes

Page 77: Hiperstation Messages and Codes

3-1

Chapter 3.

3Hiperstation Messages: EHSD through ETTERM Chap 3

The chapter explains messages with prefix EHSD through prefix ETTERM and, if applicable, provides response actions you can take to resolve the issue causing the message. Messages are listed in alpha-numeric order and grouped by prefix. Use the “Contents” to help you find the message information you need.

EHSDEHSD001 SORT FAILED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD004 END OF DBRM PROCESSING

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD010 PARM OPTIONS: DB2 RELEASE - X.X, SUPPRESS - X

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD035 I/O ERROR ENCOUNTERED ON FILE ‘SYSIN’

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD182 INVALID CONTROL CARD - IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun, if this was not expected.

EHSD183 INVALID CONTROL CARD SYNTAX

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD184 MORE THAN 30 XXX SUPPLIED - ERROR

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Reduce and rerun.

EHSD185 CONTROL CARD DATASET COULD NOT BE OPENED, A FULL LOAD WILL BE DONE

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun, if this was not expected.

EHSD186 CONTROL CARD PROCESSING ENDED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

Page 78: Hiperstation Messages and Codes

3-2 Hiperstation Messages and Codes

EHSD188 THE PLAN NAME LIST PROVIDED ENCOMPASSES MORE THAN 5000 COLLECTION IDS - RUN CANCELLED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Reduce and rerun.

EHSD281 XXX,XXX,XXX SYSPACKAGES PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD282 XXX,XXX,XXX DUPLICATE SYSSTMTS DROPPED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD283 XXX,XXX,XXX DUPLICATE SYSPACKSTMTS DROPPED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD284 XXX,XXX,XXX DUPLICATE SYSPACKSTMTS DROPPED IN E35S

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD285 DBRM DDDDDDD, STATEMENT SSSSS

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD288 XXX,XXX,XXX PACKAGES PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD289 XXX,XXX,XXX STATEMENTS PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD290 XXX,XXX VSAM RECORDS WRITTEN

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD291 NO VALID PLAN, DBRM, AND STATEMENT AT THIS POINT

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun, if this was not expected.

EHSD296 XXX,XXX,XXX DBRMS PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD304 XXX,XXX,XXX TABLES PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD305 XXX,XXX,XXX INDEXES PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

Page 79: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-3

EHSD306 TABLE XXXX INDEX YYYY

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD307 NO VALID TABLE AND INDEX AT THIS POINT

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun, if this was not expected.

EHSD309 BEGINNING CATALOG RECORD PROCESSING

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD310 STATEMENT RECORD LOAD BYPASSED BY USER REQUEST

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD311 TOO SOON TO LOAD STATEMENT RECORDS

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD312 CATALOG DATA LOAD BYPASSED BY USER REQUEST

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD313 TOO SOON TO LOAD INDEX RECORDS

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD314 CATALOG DETAIL LOAD STARTING

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD315 CATALOG DETAIL LOAD HAS ENDED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD318 XXX,XXX,XXX ALIASES PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD319 XXX,XXX,XXX VIEWS PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD320 XXX,XXX,XXX SYNONYMS PROCESSED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD330 VSAM STATEMENT DATASET BUILD ENDED NORMALLY

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

Page 80: Hiperstation Messages and Codes

3-4 Hiperstation Messages and Codes

EHSD331 VSAM STATEMENT DATASET BUILD TERMINATED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Review earlier error messages; correct them and rerun.

EHSD336 CANNOT OPEN DB2 SYSTEM TABLES

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun

EHSD346 XXX,XXX,XXX INVALID STATEMENTS DROPPED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD348 LOAD IS SELECTIVE BASED ON SAVED DEFAULT OPTIONS

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD371 BLANK CARD ENCOUNTERED, IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Informational message. No user action necessary.

EHSD372 INVALID KEYWORD VALUE - COMMAND IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD373 STATEMENT NOT TERMINATED CORRECTLY

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD374 DB2 SYSTEM ID NOT SUPPLIED ON DSN COMMAND

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD375 MEMBER NAME NOT FOUND ON DBRMLIB

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD376 VP0STMT FILE OUT OF SPACE

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD377 VSAM ERROR ENCOUNTERED ON VP0STMT, RPL FEEDBACK: FFF

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD378 DBRMLIB COULD NOT BE OPENED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD379 INVALID DBRM ENCOUNTERED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

Page 81: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-5

EHSD380 OPEN ERROR ON VP0STMT

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD381 SUPPRESS PARM IS INVALID

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD382 LOCATION NOT SUPPORTED IN PACKAGE PARAMETER, BIND COMMAND IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD383 NO PLANNAME OR PACKAGE COLLECTION ID FOUND, COMMAND IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD384 THE VP0STMT FILE FOR DB2 SYSTEM XXXX MUST BE INITIALIZED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD385 PARM IS MISSING OR INVALID

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD386 DB2 SYSTEM PARM IS MISSING OR INVALID

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD387 DB2REL PARM IS MISSING OR INVALID

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD388 LOAD PARM MUST BE: "ALL", "STMTS" OR "CATINFO"

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD389 COULD NOT DETERMINE DBRM AUTHORIZATION ID

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD390 DB2 ERROR ENCOUNTERED, ERROR TEXT:

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD391 PLAN NAME NOT BOUND IN THIS DB2 SYSTEM

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD392 COULD NOT OBTAIN EXCLUSIVE CONTROL OF THE VP0STMT FILE

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

Page 82: Hiperstation Messages and Codes

3-6 Hiperstation Messages and Codes

EHSD533 BIND HAS NO DBRM OR PACKAGE LIST, STATEMENT IGNORED

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD534 * WARNING * CONTROL INFORMATION FOR PLAN: XXXXXXX (WHICH CONTAINS PACKAGE: PPPPPPPP) IS MISSING, THE "BIND PLAN" SUBCOMMAND MUST BE RUN THROUGH THIS PROGRAM (EHSD2BTL) TO SUPPLY THE REQUIRED INFORMATION

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD535 COLLECTION NAME: CCCCCCCC NOT FOUND IN THIS DB2 SYSTEM

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSD536 * WARNING * DB2 STATEMENT = 0 FOUND FOR DBRM: DDDD - RESULTS MAY BE UNPREDICTABLE

Explanation: DB2 batch load of Statement Look-Aside dataset.

User Response: Correct and rerun.

EHSEEHSE099E DEALPIPE ERROR

Explanation: Deallocate transaction failed due to security violation.

User Response: Contact your security administrator for an explanation or correction of this situation.

EHSE201E COMPARE TERMINATED DUE TO SORT ERROR

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE202E COMPARE TERMINATED, WORKFILE A ALLOCATION ERROR

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE203E COMPARE TERMINATED, WORKFILE B ALLOCATION ERROR

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE204W COMPARE TERMINATED, NO RECORDS ON FILE A

Explanation: Compare Report.

User Response: Correct and rerun, if this was not expected.

EHSE205W COMPARE TERMINATED, NO RECORDS ON FILE B

Explanation: Compare Report.

User Response: Correct and rerun, if this was not expected.

EHSE206E COMPARE TERMINATED, INPUT FILE A ALLOCATION ERROR

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE207E COMPARE TERMINATED, INPUT FILE B ALLOCATION ERROR

Explanation: Compare Report.

Page 83: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-7

User Response: Correct and rerun.

EHSE208E COMPARE TERMINATED, REPORT FILE ALLOCATION/OPEN ERROR

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE211I END OF FILE ENCOUNTERED ON FILE A - BYPASSING REMAINING FILE B RECORDS

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE212I END OF FILE ENCOUNTERED ON FILE B - BYPASSING REMAINING FILE A RECORDS

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE227W COMPARE ERROR LIMIT EXCEEDED - PROCESSING TERMINATED

Explanation: Compare Report.

User Response: Correct and rerun, if this was not expected.

EHSE228I COMPARE PROCESSING COMPLETED

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE229I FILE ID SYNCHRONIZATION REQUIRED - RECORDS WILL BE BYPASSED

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE230I END OF FILE ENCOUNTERED ON FILE B WHILE SEARCHING FOR NEXT FILEID

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE231I END OF FILE ENCOUNTERED ON FILE A WHILE SEARCHING FOR NEXT FILEID

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSE241E ERROR OPENING TEMPORARY WORK FILE

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE242E ERROR OPENING INPUT FILE A

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE243E ERROR OPENING INPUT FILE B

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE244E ERROR FINDING INPUT FILE A LOG MEMBER

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE245E ERROR FINDING INPUT FILE B LOG MEMBER

Explanation: Compare Report.

User Response: Correct and rerun.

Page 84: Hiperstation Messages and Codes

3-8 Hiperstation Messages and Codes

EHSE246E SORT ERROR - REVIEW SYSOUT FOR DETAILS

Explanation: An error occurred in the sort program invoked by the script compare process.

User Response: Review the SYSOUT dataset or class specified on the CICS File Script Compare screen, correct the error, and rerun.

EHSE247E INVALID RECORD IN FILE A MEMBER

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE248E INVALID RECORD IN FILE B MEMBER

Explanation: Compare Report.

User Response: Correct and rerun.

EHSE286I DIFFERENCES FOUND, BUT RECORDS ARE ENCRYPTED - NOT SHOWN

Explanation: Compare Report.

User Response: Informational message. No user action necessary.

EHSPEHSP023E EXPECTED PREPARE-TO-RECEIVE FROM PARTNER NOT RECEIVED, STATUS FOLLOWS -

Explanation: A prepare-to-receive was expected from the partner but was not received.

User Response: Inspect the script and make correction.

EHSP024E ERROR DURING RECEIVE COMPLETED, STATUS FOLLOWS --

Explanation: During a normal receive where no errors were expected, an error was received.

User Response: Inspect the script and make the appropriate correction.

EHSP025E ERROR DURING RECEIVE ERROR COMPLETED, STATUS FOLLOWS --

Explanation: During a normal receive where no errors were expected, an error was received.

User Response: Inspect the script and make the appropriate correction.

EHSP026E ERROR DURING EXPEDITED RECEIVE COMPLETED, STATUS FOLLOWS --

Explanation: During an expedited receive where no errors were expected, an error was received.

User Response: Inspect the script and make the appropriate correction.

EHSP027E EXPECTED DEALLOCATE NOT FOUND, STATUS FOLLOWS --

Explanation: The partner was to send a deallocate, but it was not received.

User Response: Inspect the script and make correction.

EHSP028E EXPECTED DEALLOCATE BUT RECEIVED DATA, STATUS FOLLOWS --

Explanation: The partner was to send a deallocate, but data was received.

User Response: Inspect the script and make the appropriate correction.

EHSP029E EXPECTED RECEIVE, BUT DEALLOCATE PRESENT, STATUS FOLLOWS --

Explanation: The partner was to send data, but a deallocate was received.

User Response: Inspect the script and make the appropriate correction.

EHSP030E EXPECTED CONFIRM FROM PARTNER NOT RECEIVED, STATUS FOLLOWS -

Explanation: A Confirm was expected from the partner but was not received.

User Response: Inspect the script and make correction.

Page 85: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-9

EHSP031E DEALLOCATE LOCATED, BUT OTHER THAN LOG DATA FOUND, STATUS FOLLOWS --

Explanation: The deallocate was expected, but the log data is not correct.

User Response: Inspect the script and make the appropriate correction.

EHSP032E EXPECTED LOG DATA MISSING FOR DEALLOCATE, STATUS FOLLOWS --

Explanation: The deallocate was expected with log data, but none was found.

User Response: Inspect the script and make the appropriate correction.

EHSP041I ALLOCATE FOUND WHEN HIPERSTATION FOR MAINFRAME SERVERS WAS TO RECEIVE ALLOCATE, ALLOCATE IGNORED

Explanation: The conversation log indicates the LU was to receive an allocate, but an ALLOCATE was found in the script.

User Response: Inspect the script and make the appropriate correction.

EHSP042I ALLOCATE STATEMENT IN SCRIPT FOUND DURING CONVERSATION - IGNORED

Explanation: After a conversation started, another ALLOCATE statement was found in the script. This second ALLOCATE is ignored.

User Response: Inspect the script and remove the incorrect ALLOCATE.

EHSP051I INVALID SCRIPT RECORD TYPE FOUND

Explanation: The script contains record types that are not compatible with the type of conversation or LU.

User Response: Inspect the script and make the appropriate correction.

EHSP055I REPLAYING SCRIPT xxxxxxxx COMPARE EXCEPTIONS: xxxx/tttt

Explanation: During the playback of a 3270 script, xxxx compare exceptions were encountered out of a total of tttt screens. This message applies to 3270 terminals only.

EHSTFEHSTF001 Script mmmmmmmm already exists in OUTPUT dataset and will not be replaced.

Explanation: The mmmmmmmm script being processed already exists in your OUTPUT dataset and you have not set CONTROL REPLACE=YES.

User Response: If you want existing scripts to be replaced in your OUTPUT script dataset, you must supply the CONTROL REPLACE=YES statement.

EHSTF002 Problem with script mmmmmmmm in OUTPUT dataset:

EHSTF003 dddd

Explanation: The message filter program could not access script mmmmmmmm in the OUTPUT dataset. Message EHST003 gives details of why the script dataset could not be accessed.

User Response: Ensure that the script dataset is a PDS or PDSE, that you have authorization to access the dataset (via your site’s security product), and that the dataset is not in use by another job or user. Correct the problem outlined in dddd.

EHSTF004 Script mmmmmmmm does not exist in iiiiiiii dataset.

Explanation: You entered script mmmmmmmm, which does not exist in your INPUT dataset.

User Response: Correct or remove the incorrect member name on the SELECT SCRIPT statement.

Page 86: Hiperstation Messages and Codes

3-10 Hiperstation Messages and Codes

EHSTF005 Problem with script mmmmmmmm in INPUT dataset:

EHSTF006 dddd

Explanation: The message filter program could not access script mmmmmmmm in the INPUT dataset. Message EHST006 gives details of why the script dataset could not be accessed.

User Response: Ensure that the script dataset is a PDS or PDSE, that you have authorization to access the dataset (via your site’s security product), and that the dataset is not in use by another job or user. Correct the problem outlined in dddd.

EHSTF007 Could not close file oooooooo for script mmmmmmmm.

Explanation: A problem occurred attempting to finish processing script mmmmmmmm.

User Response: See preceding messages EHSTF031 and EHSTF032 for details.

EHSTF008 Script mmmmmmmm does not contain any <INPUT> or <OUTPUT> statements.

Explanation: There are no <INPUT> or <OUTPUT> script tags in mmmmmmmm.

User Response: Informational message. You may be processing data that is not a Hiperstation script. The script is copied unchanged to the OUTPUT dataset.

EHSTF009 Could not open file iiiiiiii for script mmmmmmmm.

Explanation: A problem was encountered attempting to start processing script mmmmmmmm.

User Response: See preceding messages EHSTF029 and EHSTF030 for details.

EHSTF010 In script mmmmmmmm, <INPUT> tag out of place on line llllllll.

Explanation: An <INPUT> tag was found while still processing a previous <INPUT> or <OUTPUT> group.

User Response: Correct the script so that no <INPUT> or <OUTPUT> tags appear between other <INPUT>…</INPUT> and <OUTPUT>…</OUTPUT> groups.

EHSTF011 In script mmmmmmmm, <OUTPUT> tag out of place on line llllllll.

Explanation: An <OUTPUT> tag was found while still processing a previous <INPUT> or <OUTPUT> group.

User Response: Correct the script so that no <INPUT> or <OUTPUT> tags appear between other <INPUT>…</INPUT> and <OUTPUT>…</OUTPUT> groups.

EHSTF012 In script mmmmmmmm, </INPUT> tag out of place on line llllllll.

Explanation: An </INPUT> tag was found while still processing a previous <OUTPUT> group or before an <INPUT> tag had been seen.

User Response: Correct the script so that no </INPUT> tag appears before a corresponding <INPUT> tag or within an <OUTPUT>…</OUTPUT> group.

EHSTF013 In script mmmmmmmm, </OUTPUT> tag out of place on line llllllll.

Explanation: An </OUTPUT> tag was found while still processing a previous <INPUT> group or before an <OUTPUT> tag had been seen.

User Response: Correct the script so that no </OUTPUT> tag appears before a corresponding <OUTPUT> tag or within an <INPUT>…</INPUT> group.

EHSTF014 Script mmmmmmmm does not end with a </gggggggg> tag.

Explanation: The end of the script was reached while an <INPUT> or <OUTPUT> group was still in effect.

User Response: Correct the script by adding the necessary </INPUT> or </OUTPUT> tag.

EHSTF015 Problem reading file iiiiiiii for script mmmmmmmm.

EHSTF016 INPUT record number(llllllll).

Explanation: A problem was encountered while reading data from script mmmmmmmm. Message EHSTF016 shows the relative record number in the member that was being processed.

Page 87: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-11

User Response: See preceding messages EHSTF025 and EHSTF026 for details.

EHSTF017 Could not open file dddddddd for script mmmmmmmm.

Explanation: A problem was encountered attempting to start processing script mmmmmmmm. The problem is with the OUTPUT dataset.

User Response: See preceding messages EHSTF029 and EHSTF030 for details.

EHSTF018 Problem writing file dddddddd for script mmmmmmmm.

EHSTF019 OUTPUT record number(llllllll).

Explanation: A problem was encountered while writing data to script mmmmmmmm in the OUTPUT dataset. Message EHSTF019 shows the relative record number in the member that was being processed.

User Response: See preceding messages EHSTF027 and EHSTF028 for details.

EHSTF020 Could not open file dddddddd for script mmmmmmmm.

Explanation: A problem was encountered attempting to start processing script mmmmmmmm. The problem is with the OUTPUT dataset.

User Response: See preceding messages EHSTF029 and EHSTF030 for details.

EHSTF021 Problem writing file dddddddd for script mmmmmmmm.

EHSTF022 OUTPUT record number(llllllll).

Explanation: A problem was encountered while writing data to script mmmmmmmm in the OUTPUT dataset. Message EHSTF022 shows the relative record number in the member that was being processed.

User Response: See preceding messages EHSTF027 and EHSTF028 for details.

EHSTF023 Problem writing file dddddddd for script mmmmmmmm.

EHSTF024 OUTPUT record number(llllllll).

Explanation: A problem was encountered while writing data to script mmmmmmmm in the OUTPUT dataset. Message EHSTF024 shows the relative record number in the member that was being processed.

User Response: See preceding messages EHSTF027 and EHSTF028 for details.

EHSTF025 For member mmmmmmmm, problem in READ_FILE routine:

EHSTF026 dddd

Explanation: A problem was encountered while reading data from the INPUT dataset. Message EHSTF026 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF027 For member mmmmmmmm, problem in WRITE_FILE routine:

EHSTF028 dddd

Explanation: A problem was encountered while writing data to the OUTPUT dataset. Message EHSTF028 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF029 For member mmmmmmmm, problem in OPEN_FILE routine:

EHSTF030 dddd

Explanation: A problem was encountered while starting to process either the INPUT or OUTPUT dataset. Message EHSTF030 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

Page 88: Hiperstation Messages and Codes

3-12 Hiperstation Messages and Codes

EHSTF031 For member mmmmmmmm, problem in CLOSE_FILE routine:

EHSTF032 dddd

Explanation: A problem was encountered while finishing processing either the INPUT or OUTPUT dataset. Message EHSTF032 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF033 For member mmmmmmmm, problem in ALLOCATE_FILE routine:

EHSTF034 dddd

Explanation: A problem was encountered while starting to process either the INPUT or OUTPUT dataset. Message EHSTF034 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF035 For member mmmmmmmm, problem in FREE_FILE routine:

EHSTF036 dddd

Explanation: A problem was encountered while finishing processing either the INPUT or OUTPUT dataset. Message EHSTF036 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF037 No scripts in dddddddd to process.

Explanation: There are no scripts in the INPUT dataset.

User Response: Enter a different INPUT dataset that contains scripts to process.

EHSTF038 The dddddddd file must be a PDS or PDSE.

EHSTF039 The dddddddd file is DSORG=oo.

Explanation: The INPUT dataset is not a partitioned dataset. Message EHSTF039 shows the dataset’s organization (DSORG).

User Response: Enter a different INPUT dataset that is a PDS or PDSE.

EHSTF040 Problem allocating dddddddd file, RC(rr), SYSREASON(ss).

Explanation: The INPUT dataset could not be accessed.

User Response: See the LISTDSI reason codes in IBM’s TSO/E Version 2 Procedures Language MVS/REXX Reference for more information.

EHSTF041 Internal error in Arrange_Parms_1

Explanation: An internal processing error occurred while running the message filter program.

User Response: Contact Compuware Customer Support for assistance.

EHSTF042 Internal error in Arrange_Parms_2

Explanation: An internal processing error occurred while running the message filter program.

User Response: Contact Compuware Customer Support for assistance.

EHSTF043 Internal error in Arrange_Parms_3

Explanation: An internal processing error occurred while running the message filter program.

User Response: Contact Compuware Customer Support for assistance.

EHSTF044 Internal error in Arrange_Parms_4

Explanation: An internal processing error occurred while running the message filter program.

User Response: Contact Compuware Customer Support for assistance.

Page 89: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-13

EHSTF045 You must supply at least one INCLUDE or EXCLUDE statement.

Explanation: You have not supplied an INCLUDE or EXCLUDE statement in your JCL for the message filter program. The INCLUDE and EXCLUDE statements identify REXX programs that select important screens from your scripts.

User Response: Supply at least one INCLUDE or EXCLUDE statement.

EHSTF046 dddddddd file contained no records.

Explanation: Your JCL does not contain any control statements for the message filter program.

User Response: Supply control statements under the SYSIN DD JCL statement.

EHSTF047 Problem allocating dddddddd file, RC(rr), SYSREASON(ss).

Explanation: The SYSIN file (or the file you have substituted for SYSIN via the PARM keyword in your JCL) cannot be accessed.

User Response: Make sure that you have a DD statement for SYSIN in your JCL. If you have entered a substitute name on the EXC PGM=IKJEFT01,PARM= statement, make sure that name is used instead of SYSIN in your JCL.

EHSTF048 File dddddddd is not allocated.

Explanation: The SYSIN, INPUT, OUTPUT, or REXX DD statements are missing from the JCL or cannot be accessed.

User Response: Verify that a dddddddd DD statement appears in the message filter JCL.

EHSTF049 Line nnnn: Unknown SYSIN control statement: ssssssss

Explanation: A statement was found in the SYSIN data that was not recognized.

User Response: Valid control statements are CONTROL, SELECT, INCLUDE, and EXCLUDE.

EHSTF060 Line nnnn: Unknown ssssssss keyword: kkkkkkkk

Explanation: A keyword was found on the ssssssss statement that was not recognized.

User Response: For the CONTROL statement, the valid keywords are DEFAULT, REPLACE, COMMENT, INDD, OUTDD, REXXDD, and REPORTDD. For the SELECT statement, the valid keyword is SCRIPT. For the INCLUDE and EXCLUDE statements, the valid keywords are TRAN and PARM.

EHSTF061 Problem with EXEC mmmmmmmm in REXX dataset:

EHSTF062 dddd

Explanation: The message filter program was unable to access your REXX dataset. Message EHSTF062 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF063 XEC mmmmmmmm, problem in BUILD_USER_EXITS routine:

EHSTF064 dddd

Explanation: The message filter program was unable to access your REXX dataset. Message EHSTF064 shows the details of the problem.

User Response: Take the corrective action indicated by the detail messages.

EHSTF065 For script mmmmmmmm, exit xxxxxxxx set HS_WHICH to (vvvvvvvv), it must be null, Previous, Current, or Next.

Explanation: Your REXX exit program passed back an invalid value in the HS_WHICH variable.

User Response: Correct your REXX exit program to pass back one of the valid values listed above.

Page 90: Hiperstation Messages and Codes

3-14 Hiperstation Messages and Codes

EHSTF066 For script mmmmmmmm, exit xxxxxxxx set HS_MATCH to (vvvvvvvv), it must be 0 or 1.

Explanation: Your REXX exit program passed back an invalid value in the HS_MATCH variable.

User Response: Correct your REXX exit program to pass back one of the valid values listed above.

EHSTF067 The iiiiiiii file must be a PDS/PDSE.

EHSTF068 The iiiiiiii file is DSORG=oo.

Explanation: The INPUT dataset is not a partitioned dataset. Message EHSTF068 shows the dataset’s organization (DSORG).

User Response: Enter a different dataset that is a PDS or PDSE.

EHSTF069 The oooooooo file must be a PDS/PDSE.

EHSTF070 The oooooooo file is DSORG=oo.

Explanation: The OUTPUT dataset is not a partitioned dataset. Message EHSTF070 shows the dataset’s organization (DSORG).

User Response: Enter a different dataset that is a PDS or PDSE.

EHSTF071 The rrrrrrrr file must be a PDS/PDSE.

EHSTF072 The rrrrrrrr file is DSORG=oo.

Explanation: The REXX dataset is not a partitioned dataset. Message EHSTF072 shows the dataset organization (DSORG) of the REXX dataset.

User Response: Enter a different dataset that is a PDS or PDSE.

EHSTF073 The iiiiiiii file has a larger record length than the oooooooo file.

Explanation: Your INPUT script dataset may contain records longer than your OUTPUT script dataset allows.

User Response: Enter an OUTPUT script dataset that has a record length (LRECL) at least as large as your INPUT dataset.

EHSTF087 Line nnnn: Only one ssssssss statement is allowed.

Explanation: Your SYSIN data contains a statement that is repeated; this particular statement is allowed only once.

User Response: Remove all but one occurrence of the statement.

EHSTF088 Line nnnn: On the ssssssss statement, the kkkkkkkk keyword is required.

Explanation: Your SYSIN data has not supplied a required keyword for one of the statements.

User Response: Add the keyword to your SYSIN statement.

EHSTF089 Line nnnn: On the ssssssss statement, only one kkkkkkkk keyword is allowed.

Explanation: Your SYSIN data contains a statement with a keyword that is repeated; this particular keyword is allowed only once.

User Response: Remove all but one occurrence of the keyword.

EHSTF090 Line nnnn: On the ssssssss statement and the kkkkkkkk keyword, the value is missing.

Explanation: You have supplied a keyword on a statement but no value for the keyword.

User Response: The keyword and value must be in the form: ‘KEYWORD=value’.

EHSTF091 Line nnnn: On the ssssssss statement and the kkkkkkkk keyword, only one value is allowed.

Explanation: Your SYSIN data contains a statement with a keyword that has multiple values; this particular keyword allows only a single value.

User Response: Remove all but one occurrence of the value for this keyword.

Page 91: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-15

EHSTF092 Line nnnn: On the ssssssss statement and the kkkkkkkk keyword, the vvvvvvvv value is not valid.

Explanation: Your SYSIN data contains a statement with a keyword that has an invalid value.

User Response: On the CONTROL statement, the DEFAULT keyword values must be INCLUDE or EXCLUDE, the REPLACE keyword values must be NO or YES, and the COMMENT keyword values must be NO or YES.

EHSTF093 dddddddd must be a PDS or PDSE.

EHSTF094 It is DSORG=oo.

Explanation: Either the INPUT or OUTPUT dataset is not a PDS. Message EHSTF094 shows the dataset organization (DSORG) of the INPUT or OUTPUT dataset.

User Response: Supply a PDS or PDSE for both the INPUT and OUTPUT datasets.

EHSTF095 Problem allocating dddddddd, RC(rr), SYSREASON(ss).

Explanation: The INPUT or OUTPUT dataset could not be accessed.

User Response: See the LISTDSI reason codes in IBM’s TSO/E Version 2 Procedures Language MVS/REXX Reference for more information.

EHSTF096 NOVALUE condition raised on line(llll):

EHSTF097 SourceLine(nnnnnnnn))

EHSTF098 Variable(rrrrrrrr)

Explanation: An internal error occurred in the message filter program. Messages EHSTF097 and EHSTF098 provide more information.

User Response: Contact Compuware Customer Support for assistance.

EHSTF099 Script mmmmmmmm contains invalid <I00> tag.

EHSTF100 You should correct this script.

Explanation: The script contains an <I00> tag, which is not valid.

User Response: If you manually entered the <I00> tag, change it to a valid value. If this tag was created by Hiperstation for VTAM, contact Compuware Customer Support for assistance.

EHSTF101 Abend code(ccc)

Explanation: A system abend of hex ccc occurred when message filter tried to open a dataset.

User Response: If the abend code is 913, your security system denied access to the dataset. In this case, shut down the global recording started task, change your security access rules to allow the global recording jobname to access the dataset, and restart the global recording started task. For other abend codes, check the MVS or OS/390 System Codes manual for an explanation of the problem.

EHSTF102 Unknown request(nn), hex(xx)

Explanation: An internal error has occurred in the message filter.

User Response: Contact Compuware Customer Support for help.

EHSTF103 <mmmmmmm>

Explanation: Diagnostic output was requested and appears in this message.

User Response: Report the information to Compuware Customer Support.

EHSTF104 Starting the ETRMMSGF exec, MSGF(xxxxxxxx)

Explanation: Message filter started successfully.

EHSTF105 Free: S99ERROR(xxxx)Free: S99INFO (xxxx)Free: S99ERSN (xxxx)Allocate: S99ERROR(xxxx)

Page 92: Hiperstation Messages and Codes

3-16 Hiperstation Messages and Codes

Allocate: S99INFO (xxxx)Allocate: S99ERSN (xxxx)

Explanation: The dynamic de-allocation for (for Free messages) or allocation (for Allocate messages) of a dataset has failed. For a description of xxxx, see the appropriate (S99…) Error Reason Codes section of the IBM Authorized Assembler Services Guide.

User Response: For Free messages, contact Compuware Customer Support for help. For Allocate messages, likely causes are that the dataset does not exist, or the global recording started task does not have security access to the dataset.

EHSTF106 Generate_report: INFO RC(nn)Generate_report: ALLOCATE RC(nn)

Explanation: Hiperstation for VTAM could not obtains dataset information via an INFO request or dynamically allocate the report dataset via an ALLOCATE request. This message displays with message EHSTF109, which shows the name of the dataset with which a problem occurred.

User Response: Ensure that the dataset exists and the script create task has access to the dataset.

EHSTF107 Generate_report: OPEN RC(nn)

Explanation: The report dataset could not be opened for output. Refer to message EHSTF109 for the name of the dataset.

User Response: Ensure the dataset exists and the script create task has write access to the dataset.

EHSTF108 Generate_report: WRITE RC(nn)

Explanation: The report dataset could not be written to. Refer to message EHSTF109 for the name of the dataset.

User Response: The likely cause is that the dataset characteristics are incorrect. Ensure that the report dataset is sequential or partitioned, and has a record format of F, FB, V, or VB.

EHSTF109 Could not write report dataset ‘dddddddd’

Explanation: This message reports the dataset causing messages EHSTF106, EHSTF107, or EHSTF108.

EHSTF110 Report dataset ‘dddddddd’ is neither sequential nor partitioned, DSORG=‘xx’xReport dataset ‘dddddddd’ is neither fixed nor variable, RECFM=‘xx’x

Explanation: The dataset organization (for the DSORG message) or record format (for the RECFM message) for the report dataset is incorrect.

User Response: Ensure that the report dataset is sequential or partitioned, and has a record format of F, FB, V, or VB.

EMALCEMALC000 DATASET IN USE - DATASET IS BEING USED BY ANOTHER USER OR JOB

Explanation: The dataset you specified is currently in use.

User Response: Wait for the other user or job to finish, then try again.

EMALC001 INVALID MEMBER NAME - MEMBER NAME CONTAINS INVALID CHARATERS OR IS TOO LONG

Explanation: The member name you specified contains either more than 8 characters or characters that the system doe s not accept.

User Response: Shorten the name to eight characters or less, or remove or change the offending characters.

EMALC002 INVALID DATASET NAME

Explanation: The dataset name you specified is invalid.

Page 93: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-17

User Response: Make sure the name is not too long and does not have invalid characters, then try again.

EMALC003 DATASET NOT A PDS

Explanation: The dataset you specified is sequential.

User Response: Use a partitioned dataset.

EMALC004 DATASET NOT FOUND - NOT ON VOLUME AS INDICATED IN CATALOG

Explanation: The dataset you specified could not be found.

User Response: Make sure the name is typed correctly and that the dataset does exist.

EMALC012 DATASET ALREADY EXISTS - THE DATASET TO BE CREATED FOR THIS OPERATION ALREADY EXISTS

Explanation: The dataset you specified already exists.

User Response: Use a name that does not exist so it can be created for this operation.

EMCATEMCAT001 DATASET HAS BEEN MIGRATED

Explanation: The dataset you specified is now backed up as an archive.

User Response: Recall the dataset and retry.

EMCAT002 ENTER A DATASET NAME

Explanation: You have not entered a dataset name.

User Response: Enter a dataset name and retry.

EMFINEMFIN000 INVALID OPERAND - VALID FIND COMMAND OPERANDS ARE ‘FIRST’, ‘LAST, ‘NEXT’, AND ‘PREV’

Explanation: You have not entered a valid find command.

User Response: Retry using either ‘FIRST’, ‘LAST’, ‘NEXT’, or ‘PREV’.

EMFIN001 REQUIRED STRING MISSING - THE FIND COMMAND REQUIRES SPECIFICATION OF A TARGET STRING

Explanation: You have used the find command without specifying a target string.

User Response: Specify the target string and retry.

EMFIN005 CHARACTERS NOT FOUND - THE CHARACTERS SPECIFIED INT HE FIND COMMAND ARE NOT IN THIS LIST

Explanation: The characters you specified as a target string were not found in the list.

User Response: Retry search with a different target string, if desired.

EMFIN008 ENTER A FIND COMMAND - THE RFIND KEY WORKS ONLY AFTER A FIND CHARACTER STRING IS ENTERED

Explanation: The RFIND command requires a previously set target string to retry the find with.

User Response: Use FIND with a target string, then repeat the find using the RFIND key.

Page 94: Hiperstation Messages and Codes

3-18 Hiperstation Messages and Codes

EMGSLEMGSL000 INVALID COMMAND - THE COMMAND ON THE COMMAND LINE IS NOT VALID FOR THIS APPLICATION

Explanation: The command you typed is not recognized by the application.

User Response: Make sure the command is spelled correctly, or try another command.

EMGSL002 INVALID LINE COMMAND - THE COMMAND ON THE COMMAND LINE IS NOT VALID FOR THIS APPLICATION

Explanation: The command you typed is not recognized by the application.

User Response: Make sure the command is spelled correctly, or try another command.

EML62 EML62001 ALLOCATION FAILURE, NO RETRY

Explanation: The conversation cannot be allocated because of a permanent condition.

User Response: The mode may have been closed, setting the session limit to zero. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0000.

EML62002 ALLOCATION FAILURE, RETRY

Explanation: The conversation cannot be allocated because of a temporary condition.

User Response: A temporary lack of resources may be the cause. A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0001.

EML62003 ALLOCATION ERROR, CONVERSATION TYPE MISMATCH

Explanation: The partner LU rejected the allocation request because the remote transaction program does not support the chosen mapped or basic conversation.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0002.

EML62004 ALLOCATION ERROR, PIP NOT ALLOWED

Explanation: The partner LU rejected the allocation request because the partner LU does not support PIP data or the remote transaction program does not contain PIP variables.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. If PIP data is not actually desired, remove it from the allocation statement. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0003.

EML62005 ALLOCATION ERROR, PIP NOT SPECIFIED CORRECTLY

Explanation: The partner LU rejected the allocation request because the local application had no PIP data and the remote transaction program expects PIP data or the local application listed a different number of PIP variables than is expected by the remote transaction program.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. Also check that PIP data is correct in the allocation statement. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0004.

EML62006 ALLOCATION ERROR, SECURITY NOT VALID

Explanation: The partner LU rejected the allocation request because the local application listed invalid access security data.

Page 95: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-19

User Response: Check that the entered user ID and password are correct. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0005.

EML62007 ALLOCATION ERROR, SYNCLEVEL NOT SUPPORTED BY LU

Explanation: The partner LU rejected the allocation request because the synchronization level set in the allocation request is not supported by both LUs.

User Response: Check that the specific SYNCLVL is supported on both the local and partner LU. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0006.

EML62008 ALLOCATION ERROR, SYNCLEVEL NOT SUPPORTED BY PGM

Explanation: The partner LU rejected the allocation request because the synchronization level set in the allocation request is not supported by the remote transaction program.

User Response: Check that the specific SYNCLVL is supported by the remote application program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0007.

EML62009 ALLOCATION ERROR, TPN NOT RECOGNIZED

Explanation: The partner LU rejected the allocation request because the chosen transaction program name is unknown to the partner LU.

User Response: Check that the TPNAME exists on the partner LU. See Communications Server SNA Programmer’s LU6.2 Reference2 for information on return code RCPRI=0004 RCSEC=0008.

EML62010 ALLOCATION ERROR, TPN NOT AVAILABLE, NO RETRY

Explanation: The partner LU rejected the allocation request. The listed transaction program name is recognized by the partner LU, but it cannot be started.

User Response: The condition is permanent. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0009.

EML62011 ALLOCATION ERROR, TPN NOT AVAILABLE, RETRY

Explanation: The partner LU rejected the allocation request. The listed transaction program name is recognized by the partner LU, but it cannot be started.

User Response: The condition is temporary. Rerunning the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=000A.

EML62015 ALLOCATION ERROR, MODE MUST BE RESTORED BEFORE USING

Explanation: The allocation request is rejected because the listed mode name is pending recovery for persistent LU-LU sessions.

User Response: See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=000E.

EML62017 ALLOCATION ERROR, SYNCLEVEL INVALID FOR FULL DUPLEX

Explanation: The allocation request is rejected because it lists a synchronization level that is not supported by full duplex.

User Response: Verify the specific SYNCLVL and TYPE. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0010.

EML62018 ALLOCATION ERROR, FULL DUPLEX NOT SUPPORTED BY LU PAIR

Explanation: The allocation request is rejected because it lists a full duplex conversation and the LU pair does not support it.

User Response: Verify the specific TYPE and that both LUs support full duplex conversations. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0004 RCSEC=0011.

Page 96: Hiperstation Messages and Codes

3-20 Hiperstation Messages and Codes

EML62031 CNOS ERROR, ALLOCATION FAILURE, NO RETRY

Explanation: The control operator conversation could not be started because of a condition that is not temporary.

User Response: See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0000.

EML62032 CNOS ERROR, ALLOCATION FAILURE, RETRY

Explanation: The control operator conversation could not be started due to a temporary condition.

User Response: A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0001.

EML62033 CNOS ERROR, TPN NOT AVAILABLE, RETRY

Explanation: The partner LU is unable to start the x‘06F1’ SNA service transaction program because of a temporary condition such as a lack of resources.

User Response: A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0002.

EML62034 CNOS ERROR, TPN NOT AVAILABLE, NO RETRY

Explanation: The partner LU is unable to start the x‘06F1’ SNA service transaction program because of a permanent condition.

User Response: See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0003.

EML62035 CNOS ERROR, CONVERSATION TYPE MISMATCH

Explanation: The partner LU rejected the CNOS conversation allocation because the remote transaction program does not support the chosen mapped or basic conversation type.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0004.

EML62036 CNOS ERROR, SECURITY NOT VALID

Explanation: The partner LU rejected the CNOS conversation allocation because the access security information supplied by VTAM is invalid.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. See Communications Server SNA Programmer’s LU6.2 Reference for information about return code RCPRI=0008 RCSEC=0005.

EML62037 CNOS ERROR, MODE MUST BE RESTORED BEFORE USING

Explanation: The partner LU rejected the CNOS conversation allocation because the listed mode name is pending recovery for persistent LU-LU sessions.

User Response: Check that you are attempting to play back to the correct LU and TPNAME. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0008 RCSEC=0006.

EML62039 CNOS ERROR, RESOURCE FAILURE, NO RETRY

Explanation: The APPCCMD CONTROL=OPRCNTL,QUALIFY=CNOS macro did not execute because a failure caused the control operator conversation to be deallocated prematurely. This is probably caused by a session outage.

User Response: See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=000C RCSEC=0000.

EML62060 THE PARTNER LU ISSUED DEALLOCATE ABEND PROGRAM

Explanation: An unexpected DEALLOCATE TYPE(ABEND_PROG) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

Page 97: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-21

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0014 RCSEC=0000.

EML62061 THE PARTNER LU ISSUED DEALLOCATE ABEND SERVICE

Explanation: An unexpected DEALLOCATE TYPE(ABEND_SVC) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0018 RCSEC=0000.

EML62062 THE PARTNER LU ISSUED DEALLOCATE ABEND TIMER

Explanation: An unexpected DEALLOCATE TYPE(ABEND_TIMER) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=001C RCSEC=0000.

EML62070 CNOS FAILURE, RETRY

Explanation: A conversation was started with the partner LU. However, a failure occurred that caused the conversation to be prematurely terminated. This could be caused by a session outage such as a line or modem failure.

User Response: A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0020 RCSEC=0000.

EML62080 LOGICAL RECORD BOUNDARY ERROR

Explanation: The application program began sending a logical record before the previous logical record was sent in its entirety. This may be caused by an error in the CONTENT records in the script.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0024 RCSEC=0000.

EML62090 LU MODE SESSION LIMIT CLOSED

Explanation: The APPCCMD CONTROL=OPRCNTL,QUALIFY=CNOS macro did not execute successfully because the partner LU will not allow the session limit for the chosen mode to be set above zero. Hiperstation for Mainframe Servers has attempted to issue a CNOS request before allocating a conversation with the chosen partner LU. However, the partner LU has already set the session limits to zero for this mode.

User Response: Check that this action by the remote transaction program is appropriate. The requested playback scenario may not be compatible with the application design. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0028 RCSEC=0000.

EML62101 PARAMETER ERROR, INVALID LU NAME OR NETWORK ID

Explanation: The listed LU name or network identifier is unknown.

User Response: Check that the correct LU name or network identifier has been entered, defined, and enabled. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0000.

EML62102 PARAMETER ERROR, INVALID MODE

Explanation: The chosen mode name is unknown or is not allowed for the chosen LU-LU pair.

User Response: Check that the correct mode name is listed for the LU-LU pair. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0001.

Page 98: Hiperstation Messages and Codes

3-22 Hiperstation Messages and Codes

EML62103 PARAMETER ERROR, INVALID CONVERSATION

Explanation: An invalid conversation ID was listed on the APPCCMD. This may be caused by the partner application issuing a REJECT.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0002.

EML62104 PARAMETER ERROR, INVALID LOGICAL RECORD LENGTH

Explanation: The supplied data record contains an invalid logical record length. This may be caused by an error in the CONTENT records in the script. The record contains a length value of X‘0000’, X‘0001’, X‘8000’, or X‘8001’. A length of X‘0001’ indicates a presentation services header and is allowed only for conversations with a synchpoint synchronization level.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0003.

EML62111 PARAMETER ERROR, INCOMPLETE FMH5 SUPPLIED

Explanation: The supplied FMH5 header is incomplete.

User Response: Call Compuware Customer Support. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=000A.

EML62112 PARAMETER ERROR, INCOMPLETE GDS VARIABLE SUPPLIED

Explanation: An abnormal termination deallocate was issued but the supplied GDS variable was incomplete. This may be caused by an error in the LOGDATA CONTENT record for the deallocate in the script.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=000B.

EML62117 PARAMETER ERROR, INVALID DATA ADDRESS OR LENGTH

Explanation: The supplied APPCCMD work area address is invalid.

User Response: Call Compuware Customer Support. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0010.

EML62118 PARAMETER ERROR, PREVIOUS MACRO OUTSTANDING

Explanation: An APPCCMD was issued that processes on the same queue as another outstanding request.

User Response: Call Compuware Customer Support. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0011.

EML62122 PARAMETER ERROR, INVALID TPN

Explanation: An allocation request with an invalid or reserved transaction program name (such as x‘06F1’) was rejected. It is not permissible to use the SNA service transaction program x‘06F1’.

User Response: Check the conversation log or script for the correct transaction program name. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0015.

EML62125 PARAMETER ERROR, INVALID LIMIT SPECIFIED

Explanation: An APPCCMD CONTROL=OPRCNTL,QUALIFY=CNOS request contained an incorrect session limit value.

User Response: Call Compuware Customer Support. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0018.

EML62129 PARAMETER ERROR, SINGLE SESS, MODE ALREADY INIT

Explanation: An APPCCMD CONTROL=OPRCNTL,QUALIFY=CNOS request was issued to a single session LU that already has a mode name initialized to a non-zero value.

User Response: Check that the conversation log does not have multiple allocate statements for playing back to the single session LU. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=001C.

Page 99: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-23

EML62133 PARAMETER ERROR, ABNORMAL DEALLOCATE REJECTED, RETRY

Explanation: An APPCCMD CONTROL=DEALLOC,QUALIFY=ABNDPROG/ABNDSERV/ABNDTIME/ABNDUSER was issued while a request that cannot be cancelled is outstanding. Or, the conversation is in RECEIVE state and no data has been received. The script is probably in error.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0021.

EML62136 PARAMETER ERROR, PS HEADER NOT SUPPLIED

Explanation: VTAM rejected the send request because the supplied PS header was incomplete. This is probably caused by incorrect data in a script’s send CONTENT statement.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0024.

EML62137 PARAMETER ERROR, PS HEADER LENGTH IS INSUFFICIENT

Explanation: VTAM rejected the send request because the supplied PS header length was insufficient (the length is zero). This is probably caused by incorrect data in a script’s send CONTENT statement.

User Response: Check that any script editing was done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0025.

EML62140 PARAMETER ERROR, CRYPTOGRAPHY NOT ALLOWED ON MODE

Explanation: A SEND was issued that set encryption, but the mode does not support it.

User Response: Check that the correct mode name has been listed in the conversation log or script allocation statement. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=0028.

EML62144 PARAMETER ERROR, INVALID EXPEDITED DATA LENGTH

Explanation: A SENDEXPD was issued that set a data length of zero, or greater than the maximum allowable size of 86 bytes. This is probably caused by incorrect data in a send-expedited CONTENT statement in the script.

User Response: Check that any script editing was done correctly and that the length of any expedited data is at least one and no more than 86 bytes. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=002C.

EML62145 PARAMETER ERROR, INVALID SENSE CODE VALUE SPECIFIED

Explanation: An APPCCMD CONTROL=DEALLOC,QUALIFY=ABNDUSER was issued that set an invalid sense code value. This is probably caused by incorrect data in the SENSE operand of the CMDEAL statement in the script.

User Response: Check that any SENSE operand sets a valid sense code. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=002C RCSEC=002D.

EML62200 PROGRAM ERROR NO TRUNCATION

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(PROG) but the data that has been received (if any) is a complete logical record. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

User Response: Check that the correct partner LU and remote transaction program are set, and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0030 RCSEC=0000.

EML62201 PROGRAM ERROR PURGING

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(PROG) and may have purged data. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

Page 100: Hiperstation Messages and Codes

3-24 Hiperstation Messages and Codes

User Response: Check that the correct partner LU and remote transaction program are set and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0034 RCSEC=0000.

EML62202 PROGRAM ERROR TRUNCATING

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(PROG) but the data that has been received (if any) is a truncated logical record. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

User Response: Check that the correct partner LU and remote transaction program are set and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0038 RCSEC=0000.

EML62203 SERVICE ERROR NO TRUNCATION

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(SVC) but the data that has been received (if any) is a complete logical record. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

User Response: Check that the correct partner LU and remote transaction program are set and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=003C RCSEC=0000.

EML62204 SERVICE ERROR PURGING

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(SVC) and may have purged data. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

User Response: Check that the correct partner LU and remote transaction program are set and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0040 RCSEC=0000.

EML62205 SERVICE ERROR TRUNCATING

Explanation: The remote transaction program issued an unexpected SEND_ERROR TYPE(SVC) but the data that has been received (if any) is a truncated logical record. This may be caused by changes to the remote transaction program that have rendered it incompatible with the script. It may also be caused by incorrect changes being made to the script.

User Response: Check that the correct partner LU and remote transaction program are set and that the program is not changed in a way that affects the conversation. The script may need to be re-recorded. Also, check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0044 RCSEC=0000.

EML62206 RESOURCE FAILURE, NO RETRY

Explanation: The conversation has been prematurely terminated by a permanent resource failure. This has probably been caused by a failure at the partner LU. This may also be caused by a protocol violation by the local LU.

User Response: Determine the reason for the failure on the partner LU. Check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0048 RCSEC=0000.

EML62207 RESOURCE FAILURE, RETRY

Explanation: The conversation has been prematurely terminated by a temporary resource failure. This may be caused by a session outage such as a modem or line failure.

Page 101: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-25

User Response: A rerun of the playback function may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=004C RCSEC=0000.

EML62208 STATE ERROR

Explanation: A request was issued that is inappropriate in the current conversation state. This may be caused by a change in the remote transaction program or by an incorrect change being made to the script.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, it may be necessary to re-record the script. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0050 RCSEC=0000.

EML62209 UNRECOGNIZED MODE NAME

Explanation: A CNOS request failed because the listed mode name is unknown.

User Response: Check that the mode name entered in the conversation log or script is correct and defined. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0054 RCSEC=0000.

EML62220 USER ERROR CODE RECEIVED FOLLOWING A NEGATIVE RESPONSE

Explanation: A sense code not interpreted by VTAM was received following a negative response. The SEND_ERROR from the partner LU was unexpected.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, it may be necessary to re-record the script. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=005C RCSEC=0000.

EML62221 USER ERROR CODE RECEIVED WITHOUT NEGATIVE RESPONSE

Explanation: A sense code not interpreted by VTAM was received but was not preceded by a negative response.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, it may be necessary to re-record the script. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=005C RCSEC=0001.

EML62234 TEMPORARY STORAGE OR RESOURCE SHORTAGE

Explanation: VTAM was unable to process a request because of a temporary storage or resource shortage.

User Response: A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0070 RCSEC=0000.

EML62235 HALT ISSUED

Explanation: The operator has issued a HALT command.

User Response: The playback must be rerun at a later time. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0074 RCSEC=0000.

EML62236 VTAM INACTIVE FOR YOUR ACB

Explanation: The ACB for the application is in the process of being closed because VTAM has become inactive or the operator has issued a VARY NET,INACT for the LU.

User Response: The playback must be rerun at a later time. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0078 RCSEC=0000.

EML62237 REQUEST ABORTED

Explanation: VTAM has rejected the request because of an error detected during processing or an error in the session, task, or address space. This could result from an abend.

User Response: The reason for the error must be determined. Check the job log. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=007C RCSEC=0000.

Page 102: Hiperstation Messages and Codes

3-26 Hiperstation Messages and Codes

EML62238 DEALLOCATE NORMAL

Explanation: The remote transaction program issued an unexpected DEALLOCATE. This is reported when a SEND_ERROR is requested in RECEIVE state and the partner has deallocated the conversation.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, the script may need to be re-recorded. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0080 RCSEC=0000.

EML62239 STORAGE SHORTAGE

Explanation: VTAM has encountered a storage shortage while attempting to complete a RECEIVE request.

User Response: A rerun of the playback may correct the problem. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0084 RCSEC=0000.

EML62240 CANCELED BY REJECT OR ABNORMAL DEALLOCATE

Explanation: An in-progress request was cancelled by the partner LU with a REJECT or abnormal deallocate.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, the script may need to be re-recorded. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0088 RCSEC=0000.

EML62241 PARTNER COMMITTED PROTOCOL VIOLATION

Explanation: The partner LU has violated conversation protocols.

User Response: Check for errors at the partner LU. The cause of the problem is probably there. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=008C RCSEC=0000.

EML62242 APPLICATION NOT APPC CAPABLE

Explanation: The local LU being used for the playback has been defined as APPC=NO on the APPL definition statement.

User Response: Use a different LU name or correct the LU definition. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0090 RCSEC=0000.

EML62244 TEMPORARY STORAGE SHORTAGE WHILE SENDING DATA

Explanation: A storage shortage occurred while attempting to send data.

User Response: Ensure that storage requirements can be met and rerun the playback. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=0098 RCSEC=0000.

EML62300 REQUEST N/A, LU PAIR DOES NOT SUPPORT EXPEDITED DATA

Explanation: One or both of the LUs does not support expedited data.

User Response: Rerun the playback using an LU pair that supports expedited data. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A0 RCSEC=0001.

EML62301 REQUEST N/A, REQUEST BLOCKED

Explanation: VTAM rejected the request because the conversation is in the process of being deallocated or terminated.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, the script may need to be re-recorded. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A0 RCSEC=0002.

Page 103: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-27

EML62302 REQUEST N/A, EXECUTION OF REQUEST TERMINATED

Explanation: VTAM rejected a RECEIVE_EXPEDITED request because the partner LU is waiting for a change-direction before sending error data.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, the script may need to be re-recorded. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A0 RCSEC=0003.

EML62303 REQUEST N/A, CONTROL/QUALIFY VALUE INVALID FOR FULL DUPLEX

Explanation: A request that is not valid in a full duplex conversation was issued and rejected. This may be caused by incorrectly listing a full duplex conversation on the allocation or by incorrectly adding statements to the script.

User Response: Check that any script editing has been done correctly and that the script is compatible with the remote transaction program. If changes have been made, the script may need to be re-recorded. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A0 RCSEC=0004.

EML62304 REQUEST N/A, RSP NOT RECEIVED FOR PREVIOUS SENDEXPD

Explanation: The local application has sent a SENDEXPD before the partner application has received a previous SENDEXPD.

User Response: Check that the script being played back is compatible with the remote transaction program. The script should be able to receive all expedited data that is sent to it. Also check that any script modifications were done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A0 RCSEC=0005.

EML62320 MODE MUST BE RESTORED BEFORE USING

Explanation: The request is rejected because the listed mode name is pending recovery for persistent LU-LU sessions.

User Response: See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00A4 RCSEC=0000.

EML62350 ERROR INDICATION RECEIVED, DEALLOCATE ABEND PROGRAM

Explanation: An unexpected DEALLOCATE TYPE(ABEND_PROG) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0003.

EML62351 ERROR INDICATION RECEIVED, DEALLOCATE ABEND SERVICE

Explanation: An unexpected DEALLOCATE TYPE(ABEND_SVC) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0003.

EML62352 ERROR INDICATION RECEIVED, DEALLOCATE ABEND TIME

Explanation: An unexpected DEALLOCATE TYPE(ABEND_TIMER) was received from the partner LU. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0003.

EML62353 ERROR INDICATION RECEIVED, ALLOCATION ERROR

Explanation: An unexpected DEALLOCATE TYPE(ABEND) was issued by the partner LU. The sense code indicated that an allocation request was rejected. An application error is the

Page 104: Hiperstation Messages and Codes

3-28 Hiperstation Messages and Codes

probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0004.

EML62354 ERROR INDICATION RECEIVED, UNKNOWN ERROR CODE

Explanation: An unexpected DEALLOCATE TYPE(ABEND) was issued by the partner LU. The returned sense code is unknown. An application error is the probable cause of the abend. Program changes on the partner LU may have made the script obsolete.

User Response: Check that the script being played back is compatible with the remote transaction program. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0005.

EML62355 ERROR INDICATION RECEIVED, RESOURCE FAILURE, RETRY

Explanation: The conversation has been prematurely terminated by a temporary resource failure. This has probably been caused by a failure at the partner LU.

User Response: Determine the reason for the failure on the partner LU. Check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information on return code RCPRI=00AC RCSEC=0006.

EML62356 ERROR INDICATION RECEIVED, RESOURCE FAILURE, NO RETRY

Explanation: The conversation has been prematurely terminated by a permanent resource failure. This has probably been caused by a failure at the partner LU.

User Response: Determine the reason for the failure on the partner LU. Check that any script editing has been done correctly. See Communications Server SNA Programmer’s LU6.2 Reference for information about return code RCPRI=00AC RCSEC=0007.

EML62901 UNKNOWN APPC ERROR

Explanation: An unknown error condition has been received. A second message, ETPO629I, follows. This message contains return code information pertinent to the problem.

User Response: Call Compuware Customer Support.

EMLOEMLOC000 INVALID OPERAND - VALID FIND COMMAND OPERANDS ARE "FIRST", "LAST", "NEXT", AND "PREV"

Explanation: You have entered an invalid find command operand.

User Response: Use ‘FIRST’, ‘LAST’, ‘NEXT’, or ‘PREV’.

EMLOC001 REQUIRED LABEL MISSING - THE LOCATE COMMAND REQUIRES A NUMBER OR LABEL AS AN OPERAND

Explanation: You did not specify a label with the locate command.

User Response: Enter a number or label with the locate command.

EMLOC002 LABEL NOT DEFINED - THE LABEL ON THE LOCATE COMMAND HAS NOT BEEN DEFINED

Explanation: The command you typed is not recognized by the application.

User Response: Make sure the label is typed correctly, or specify another label.

EMLOC003 INVALID DECIMAL NUMBER - OPERAND MUST BE A VALID DECIMAL NUMBER, OR PREDEFINED LABEL

Explanation: The operand you used is invalid.

User Response: Use a valid decimal number or a defined label.

Page 105: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-29

EMOBEMOBT000 DATASET NOT FOUND - DATASET NOT FOUND ON THE VOLUME SPECIFIED

Explanation: The dataset you specified could not be found.

User Response: Make sure the name is typed correctly and the dataset exists.

EMOBT002 DATASET IS MIGRATED - PLEASE CONTACT YOUR INSTALLATION OR PRODUCT SUPPORT PERSONNEL

Explanation: The dataset you specified is now backed up as an archive.

User Response: Recall the dataset and retry.

EMSCREMSCR000 DATASET IS IN USE - PLEASE CONTACT YOUR INSTALLATION OR PRODUCT SUPPORT PERSONNEL

Explanation: The dataset you specified is currently in use.

User Response: Wait for the other user/job to finish, then retry.

EMSRTEMSRT001 PARAMETER MISSING - COLUMN NAME OR OFFSET MUST BE SPECIFIED SLU

Explanation: You have omitted a parameter with the command.

User Response: Specify a column name or offset along with the command.

EMSRT002 INVALID COLUMN NAME - COLUMN NAME UNKNOWN OR EXCEEDS 25 CHARS SLU

Explanation: The column name you specified is invalid.

User Response: Make sure the name is spelled correctly and is fewer than 25 characters long.

EMSRT004 PARM LENGTH ERROR - SORT PARAMETER LENGTH CANNOT EXCEED 67 POSITIONS SLU

Explanation: The parameter length you specified has exceeded 67 positions.

User Response: Try again using a smaller number of parameters.

EMTCPEMTCP000 &TF2CL8 ADDRESS SEGMENTS ONLY THREE POSNS EACH, ROW &TF2CL5

Explanation: The address segments you specified were more than three positions each.

User Response: Try again using address segments that are three positions long.

EMTCP001 &TF2CL8 ADDRESS SEGMENTS MUST BE WILDCARD OR NUMERIC, ROW &TF2CL5

Explanation: The address segments you specified are invalid.

User Response: Retry using either numeric or wildcard segments.

EMTCP002 &TF2CL8 ADDRESS SEGMENTS MUST BE 000-255, ROW &TF2CL5 SLU

Explanation: The address segments you specified are invalid.

User Response: Retry using segment values between 000 and 255.

Page 106: Hiperstation Messages and Codes

3-30 Hiperstation Messages and Codes

EMTCP003 &TF2CL8 PORT MUST BE EITHER WILDCARD OR NUMERIC, ROW &TF2CL5

Explanation: The port you specified is invalid.

User Response: Retry using either a numeric or wildcard port.

EMTCP004 &TF2CL8 PORT NUMBER MUST BE 0-65535, ROW &TF2CL5

Explanation: The port you specified is invalid.

User Response: Retry using port values between 0 and 65535.

EMTCP005 PROTOCOL MUST BE TCP OR HTTP OR HTTPS, ROW &TF2CL5

Explanation: You have specified an invalid protocol.

User Response: Retry using either TCP, HTTP, or HTTPS.

EMTCP012 FIRST GT LAST - FIRST NUMBER CANNOT BE GREATER THAN LAST NUMBER

Explanation: The first number is greater than the last number.

User Response: Make sure the first number is not greater than the last number.

EMTCP013 SYNTAX ERROR IN DATASET NAME

Explanation: The dataset name you specified is invalid.

User Response: Retry verifying that the dataset exists and is spelled correctly.

EMTCP014 USE FORCE BEFORE UPDATE - YOU MAY NOT UPDATE AN ACTIVE TCP/IP REQUEST. ISSUE FORCE (F), FIRST

Explanation: You have attempted to update an active TCP/IP request.

User Response: Issue the FORCE command before attempting to update the request.

EMTCP015 WHEN MONTH/DAY ARE PRESENT, YEAR MUST BE 1999-2040

Explanation: The year you have entered is out of range.

User Response: Make sure the YEAR is between 1999 and 2040.

EMTCP016 MULTIPLE WILDCARDS SCATTERED THROUGH DATASET NAME ARE INVALID

Explanation: You have used multiple wildcards in the dataset name.

User Response: Retry using only one wildcard in the name.

EMTRGEMTRG001 Invalid Chars Entered - Enter Numeric and/or Alphabetic Characters (0-9, A-Z, a-z, #, $, @, !, or %)

Explanation: The character you specified is invalid.

User Response: Enter a valid character from the displayed list.

EMTRMEMTRM004 COMMAND NOT RECOGNIZED - THE COMMAND ENTERED ON THE COMMAND LINE IS NOT A VALID COMMAND NAME

Explanation: The command you entered is invalid.

User Response: Make sure the command is spelled correctly and is a valid command name.

EMTRM005 INVALID PFK NUMBER - THE PFK NUMBER ENTERED MUST BE BETWEEN 1 AND 24

Explanation: The PFK number you entered is invalid.

User Response: Retry using a PFK number between 1 and 24.

Page 107: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-31

EMTRM006 INCOMPLETE PFK COMMAND - THE PFK COMMAND MUST BE FOLLOWED BY ONE OR TWO DECIMAL DIGITS FROM 1 TO 24

Explanation: The PFK command must be followed by a numeric parameter.

User Response: Retry using a PFK number between 1 and 24.

EMTRM007 PFK ZERO DOES NOT EXIST - THE PFK COMMAND MUST BE FOLLOWED BY ONE OR TWO DECIMAL DIGITS FROM 1 TO 24

Explanation: The PFK number you specified is invalid.

User Response: Retry using a PFK number between 1 and 24.

EMTRM011 OPEN OF &ETRMMEM FAILED - DATASET CANNOT BE OPENED/ALLOCATED, DCB INCORRECT OR NO UPDATE AUTH

Explanation: The dataset you specified cannot be opened.

User Response: Make sure you have the correct DCB and that you have update authority.

EMTRM016 SCRIPT SPECIFIED DOES NOT EXIST

Explanation: The script listed on the SCRIPT statement was not found.

User Response: Correct the SCRIPT statement or ensure that the script is a member in the dataset referenced by the SYSLIB DD statement.

EMTRM021 INVALID FIELD NUMBER - ETRMRPLA FOUND AN INPUT FIELD RECORD WITH AN INVALID FIELD NUMBER

Explanation: There is an input field record with an invalid field number.

User Response: Retry using a valid field number.

EMTRM026 TPF IS NOT ACTIVE, CALL OPERATIONS

Explanation: The domain destination listed after the GROUP statement is not active.

User Response: Verify that the domain destination after the GROUP statement is correct and that the domain destination is active.

EMTRM027 TPF IS NOT KNOWN OR HAS NOT BEEN ACTIVATED

Explanation: The domain destination listed after the GROUP statement is not known.

User Response: Verify that the domain destination after the GROUP statement is correct and that the domain destination has been verified active to VTAM.

EMTRM029 INVALID PARAMETER - PARAMETER IS NOT A NUMERIC VALUE BETWEEN 0 AND 9999

Explanation: The parameter you specified is not valid.

User Response: Retry using a numeric parameter between 0 and 9999.

EMTRM030 INVALID PFK NAME - PF KEYS MUST BE CHARACTERS "PF" FOLLOWED BY 1 THROUGH 24

Explanation: The PFK name you specified is invalid.

User Response: Retry using characters PF followed by 1 through 24.

EMTRM033 PFK ZERO DOES NOT EXIST - ONLY PF KEY NUMBERS ONE THROUGH TWENTY-FOUR ARE SUPPORTED

Explanation: You specified a PFK of zero, which is invalid.

User Response: Retry using a PFK value between 1 and 24.

EMTRM034 NUMBER MUST BE 1 TO 24 - ONLY PF KEY NUMBERS ONE THROUGH TWENTY-FOUR ARE SUPPORTED

Explanation: The PFK value you specified is invalid.

User Response: Retry using a PFK value between 1 and 24.

Page 108: Hiperstation Messages and Codes

3-32 Hiperstation Messages and Codes

EMTRM036 DATASET IS OPEN - THE DATASET SPECIFIED IS IN USE IN ANOTHER APPLICATION

Explanation: The dataset you specified is currently in use.

User Response: Wait for the other user/job to finish, then try again.

EMTRM038 NOT VALID HERE - THE COMMAND ENTERED CANNOT BE ENTERED UNTIL THE CONTINUE COMMAND IS ENTERED

Explanation: The command you specified cannot be entered at this time.

User Response: Issue the CONTINUE command first.

EMTRM039 EXCESSIVE NNNN AMOUNT - THE NNNN AMOUNT ON THE COMMAND EXCEEDED THE LIMIT OF 9999

Explanation: The amount you specified is larger than 9999.

User Response: Retry using a number not greater than 9999.

EMTRM040 NODE NOT DEFINED TO VTAM OR HAS NOT BEEN ACTIVATED

Explanation: The virtual terminal (node) listed on the TERM() parameter is not defined to VTAM or has not been activated.

User Response: Verify that the TERM() parameter is correct and that the node has been verified active to VTAM.

EMTRM041 OPEN MACRO RETURN CODE ffff . . . CALL SUPPORT

Explanation: An error was detected when connecting the Hiperstation for VTAM Virtual Terminal ACB. ffff is the returned feedback code.

User Response: Review the section of IBM’s z/OS Communications Server: SNA Programming manual that describes the Open macroinstruction for an explanation of the feedback code (ffff), or contact Compuware Customer Support.

EMTRM042 NO VIRTUAL TERMINALS ARE AVAILABLE

Explanation: A session could not be established because all of the defined virtual terminals are currently in use.

User Response: Verify that the TERM(n) parameter on the GROUP statement lists the total number of terminals you have defined or define more terminals.

EMTRM045 DATASET BUSY - A RECORDING ON THAT DATASET IS ALREADY BEING MADE BY ANOTHER USER

Explanation: The dataset you specified is currently in use.

User Response: Wait for the user/job to finish, then try again.

EMTRM047 VTAM INITIALIZATION ERROR

Explanation: The logmode listed on the GROUP statement was not found.

User Response: Check the LOGMODE table for the virtual terminal definition for the logmode name.

EMTRM048 END HAS NO EFFECT - USE THE CANCEL COMMAND FOR AN EMERGENCY EXIT FROM HIPERSTATION

Explanation: The END command has no effect at this time.

User Response: Use the CANCEL command instead.

EMTRM050 SPECIFY A MEMBER NAME - A MEMBER NAME MUST BE SPECIFIED FOR THIS OPERATION

Explanation: You did not specify a member name.

User Response: Retry specifying a valid member name.

EMTRM051 APPLICATION DID NOT RESPOND - PORT TIMED OUT

Explanation: The application’s response time reached the time limit set by the XTRMUTIM parameter in ISPPLIB member ETRMSPAR, or by the MAXWAIT parameter in a unattended

Page 109: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-33

mode function.Can also be caused during use of Application Profiling. Application Profiling makes the assumption that unless the previous input was a CLEAR key, that the application will respond with an OUTPUT after the user enters some form of INPUT. This causes Application Profiling to wait for the OUTPUT up to the time specified on the MAXWAIT parameter. If Hiperstation for VTAM does not get a response, it issues a time out message, such as EMTRM051, and continues the playback.

User Response: Increase the time limit of the XTRMUTIM parameter if you are operating in online mode. If you are in unattended mode, increase the time limit of the MAXWAIT parameter.Check also to see if Application Profiling is on or off. If it is on, turning it off may correct the problem.

EMTRM052 THE RECORD FORMAT OF THIS DATASET MUST BE VARIABLE

Explanation: The dataset name specified is not variable.

User Response: Specify a dataset which has RECFM=VB.

EMTRM053 MUST BE A PDS

Explanation: The dataset you entered is not partitioned.

User Response: Enter the name of a partitioned dataset.

EMTRM054 IMS TIME OUT OCCURRED

Explanation: The application did not respond within your installation-specified time limit. The PORT is timed out.

User Response: You set this time limit in different ways for interactive sessions and unattended playbacks. For unattended playback, enter the time in hundredths of seconds on the CONTROl statement in parameter KEY2. For interactive sessions, enter the time in hundredths of seconds on XTRMKTIM in ISPF panel ETRMSPAR. The default value is 2500.

EMTRM059 MEMBER ALREADY EXISTS - EITHER CHANGE THE MEMBER NAME, OR SELECT - REPLACE LIKE MEMBER(S)

Explanation: The member you specified already exists.

User Response: Retry using a different member name, or select replace like members if you want to replace it.

EMTRM060 UNEXPECTED DROP BY VTAM. NODE NAME = &ETRMSLU RETURN CODE = &XTRMGCH1 SENSE CODE = &XTRMGCH2.

Explanation: The Hiperstation Virtual Terminal's connection was unexpectedly terminated by VTAM.

User Response: Determine the reason for the session drop by VTAM of terminal &ETRMSLU. The return code &XTRMGCH1 and sense code &XTRMGCH2 can be found in the IBM z/OS Communication Server IP and SNA Codes manual.

EMTRM064 TPF DID NOT RESPOND TO THE BIND REQUEST

Explanation: The domain destination did not acknowledge the bind from Hiperstation for VTAM.

User Response: Verify that the domain destination is active. Check the log of the domain destination for related error messages. Investigate using the LOGD() parameter on the GROUP statement.

EMTRM069 MODE TABLE FOR &ETRMLGMD NOT FOUND IN VTAMLIB, PLU=&ETRMREQS, SLU=&ETRMSLU

Explanation: The Mode Table for the specified Logmode (&ETRMLGMD) cannot be found. 7ETRMREQS is the Primary Logical Unit, &ETRMSLU is the Secondary Logical Unit.

User Response: Make sure the Logmode specified exists in a VTAM Mode Table within the system in use.

Page 110: Hiperstation Messages and Codes

3-34 Hiperstation Messages and Codes

EMTRM071 TERMINAL IS NOT NON-SNA

Explanation: Attempting to communicate with an unsupported device.

User Response: Contact Compuware Customer Support.

EMTRM072 NO SPACE IN DIRECTORY - SCRIPT PDS DIRECTORY IS FULL, THE RECORDING WAS NOT SAVED.

Explanation: Your script PDS has run out of space.

User Response: Retry after you free up some space or point to another PDS.

EMTRM074 INVALID SELECT CODE - VALID LINE COMMANDS ARE: "B"-BROWSE, "E"-EDIT, AND "S"-SELECT

Explanation: You specified an invalid line command.

User Response: Retry using B, E, or S.

EMTRM081 INVALID CURSOR POSITION - THE CURSOR POSITION IS NOT WITHIN THE SCREEN AND IS NOT USED

Explanation: The current cursor position is not within the screen and is invalid.

User Response: Move the cursor to a position within the screen and try again.

EMTRM087 THE SCRIPT BEGINS WITH AN INPUT SCREEN - UNKNOWN SCREEN SIZE

Explanation: The script to be demonstrated begins with an input screen; the number of screen rows and columns are unknown. The screen cannot be correctly displayed.

User Response: Determine: (1) if the script has output screens recorded; (2) if the script has been edited; and (3) if the script is valid. Press Enter to display the next screen in session demo. Press the End key to end the session demo.

EMTRM088 SCRIPT INPUT SCREEN HAS NO ASSOCIATED OUTPUT SCREEN

Explanation: The script to be demonstrated has consecutive input screens; the number of screen rows and columns cannot be determined. The screen cannot be correctly displayed.

User Response: Determine: (1) if the script has output screens recorded; (2) if the script has been edited; and (3) if the script is valid. Press Enter to display the next screen in session demo. Press the End key to end the session demo.

EMTRM092 RECORD NOT FOUND - THE SELECTED RECORD COULD NOT BE FOUND IN THE DATABASE

Explanation: The record you selected could not be found.

User Response: Make sure the record is spelled correctly and exists, then retry.

EMTRM100 RECORDING ERROR - RECORDING FILE USED ALL OF ITS EXTENTS OR NO MORE SPACE AVAILABLE ON VOLUME

Explanation: The recording file is full, or you have run out of space.

User Response: Free up some space, or use another dataset.

EMTRM101 RECORDING ERROR - SYSTEM SECURITY DENIED ACCESS TO THE SPECIFIED RECORDING FILE

Explanation: You do not have access to the recording file.

User Response: Use another recording file or contact your security administrator for access.

EMTRM102 NOT VALID HERE - THIS COMMAND REQUIRES THAT EITHER PLAY OR RECORD IS ACTIVE

Explanation: The command you entered is not valid at this time.

User Response: Make sure you are PLAYing or RECORDing, then retry.

EMTRM104 SECURITY DENIES REQUEST - SYSTEM SECURITY INTERFACE (RACF OR OTHER) DECIDED USER ID IS RESTRICTED

Explanation: Your request was denied because your user ID is restricted.

Page 111: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-35

User Response: Contact your security administrator for access.

EMTRM106 DATASET IS FULL - DATASET &ETRMXDSN IS FULL. FUTURE UPDATES WILL BE LOST

Explanation: The dataset you are using is now full.

User Response: Make dataset attributes larger or use another dataset.

EMTRM107 SECURITY DENIES REQUEST - SYSTEM SECURITY INTERFACE (RACF OR OTHER) DENIED ACCESS TO UNFORMATTED RECORD

Explanation: Your request was denied because your user ID is restricted.

User Response: Contact your security administrator for access.

EMTRM108 SECURITY DENIES REQUEST - SYSTEM SECURITY INTERFACE (RACF OR OTHER) DENIED ACCESS TO DEBUG OPTION

Explanation: Your request was denied because your user ID is restricted.

User Response: Contact your security administrator for access.

EMTRM110 INVALID DATE/TIME - THE START DATE/TIME MUST BE LESS THAN THE STOP DATE/TIME

Explanation: The start date/time needs to be earlier than the end date/time.

User Response: Change the date/times so that the start date/time is earlier than the stop date/time and retry.

EMTRM111 MISSING DATE - A DATE MUST BE PROVIDED IF THE TIME IS SPECIFIED

Explanation: You need to enter a date if you specified a time.

User Response: Either enter a date, or remove the time.

EMTRM113 NO MATCHES - THE SPECIFIED PARTITIONED DATASET CONTAINS NO MATCHING MEMBERS

Explanation: The PDS you specified contains no matching members.

User Response: Make sure everything is spelled correctly and retry.

EMTRM115 SECURITY DENIES REQUEST - ACCESS TO DOMAIN DESTINATION RESTRICTED BY SYSTEM SECURITY (RACF OR OTHER)

Explanation: Your request was denied because your user ID is restricted.

User Response: Contact your security administrator for access.

EMTRM116 SECURITY DENIES REQUEST - SYSTEM SECURITY INTERFACE (RACF OR OTHER) DECIDED LU NAME IS RESTRICTED

Explanation: Your request was denied because your user ID is restricted.

User Response: Contact your security administrator for access.

EMTRM117 SECURITY DENIES REQUEST - SYSTEM SECURITY INTERFACE (RACF OR OTHER) DECIDED THIS FUNCTION IS RESTRICTED

Explanation: Your request was denied because your user ID is restricted.

User Response: Contact your security administrator for access.

EMTRM118 INVALID SCRIPT RECORD

Explanation: An invalid script item was found in the script. This could be encountered when trying to playback a script on a release less than that on which it was recorded, or if the script was incorrectly altered.

User Response: Play back the script on the same release (or greater) as the release on which it was recorded, or correct the editing error.

EMTRM120 RECORDING ALREADY ACTIVE - RECORDING HAS ALREADY BEEN ACTIVATED. ONLY ONE RECORD OPERATION MAY BE ACTIVE

Explanation: Recording is already in progress.

Page 112: Hiperstation Messages and Codes

3-36 Hiperstation Messages and Codes

User Response: Stop recording, then retry.

EMTRM124 THE VALUES SPECIFIED BY XTRMPRFX AND XTRMSUFX ARE NOT COMPATIBLE

Explanation: The combined length of Virtual Terminal Prefix (&XTRMPRFX for Domain Traveler of PREFIX for Unattended Playback) and Virtual Terminal Suffix (&XTRMSUFX for Domain Traveler or SUFFIX for Unattended Playback) is greater than eight characters.

User Response: Verify the defined Virtual Terminal names on your system and correct the appropriate parameter setting.

EMTRM127 REXX LOG IS IN USE - THE REXX LOG CANNOT BE CHANGED WHILE PLAY IS ACTIVE

Explanation: You cannot modify the REXX log while PLAYing a script.

User Response: Wait until you are finished PLAYing the script, then retry.

EMTRM128 ISSUE FORCE (F), THEN UPDATE (U) USE FORCE BEFORE UPDATE. YOU MAY NOT UPDATE AN ACTIVE APPC REQUEST.

Explanation: This message appears on the Global Recording Monitor Requests scree n under ISPF if you attempt to update an APPC request that is still active.

User Response: To update an APPC request you must either: (1) force the request with the F line command; or (2) stop the request with the P line command and wait until all active conversations have completed. You can then update the request with the U line command.

EMTRM129 DATASET LRECL TOO SMALL. SCRIPT DATASET MUST HAVE AN LRECL LARGER THAN SCREEN WIDTH PLUS 8

Explanation: This message appears if you attempt to record a 3270 session to a dataset with a logical record length (LRECL) that is too small.

User Response: You must enter the name of a partitioned dataset (PDS) with a record format of variable blocked (VB) and an LRECL of at least 88 for 3270 sessions.

EMTRM130 SPECIFY A MEMBER NAME - A MEMBER NAME MUST BE SPECIFIED FOR THIS OPERATION

Explanation: No member name was specified.

User Response: Specify a member name, and retry.

EMTRM131 MUST BE A SEQ DS - THE DATASET SPECIFIED IS NOT SEQUENTIAL. THIS OPERATION REQUIRES DSORG=PS

Explanation: The dataset you specify needs to be sequential.

User Response: Use a sequential dataset with DSORG=PS.

EMTRM134 NO LOGMODE BIND TIME OUT

Explanation: The domain destination requires a VTAM LOGMODE to run successfully

User Response: When using unattended playback, define the LOGM parameter within the GROUP statement. When using online playback, complete the Node name field. The Hiperstation for VTAM panel library ETRMSPAR member lists the valid LOGMODES.

EMTRM136 USER IS NOT AUTHORIZED - YOUR USERID MUST MATCH THE USERID IN THE SCRIPT YOU ARE PLAYING

Explanation: Your user ID does not match the user ID in the script.

User Response: Play the script from the script user IDs session.

EMTRM137 0229 INVALID NOT LEAP YR - THE YEAR ENTERED WITH FEB 29 IS NOT A LEAP YEAR

Explanation: The year you entered is not a leap year, it does not have Feb. 29.

User Response: Change the year to a leap year, or change the 0229.

EMTRM138 LIST OF ANOTHER USER - MUST BE ADMIN MODE TO EDIT/DELETE LIST CREATED BY ANOTHER USER

Explanation: You cannot edit/delete another users list unless you are in ADMIN mode.

User Response: Retry while in ADMIN mode.

Page 113: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-37

EMTRM139 SPECIFY A VALID LIST NAME - THE NAME OF AN EXISTING IN/EXCLUDE LIST MUST BE SPECIFIED

Explanation: The list name you specified is invalid.

User Response: Make sure the name you specify exists and is spelled correctly, then retry.

EMTRM152 MUTUALLY EXCLUSIVE - CANNOT SPECIFY A LIST AS WELL AS TERMINAL/APPLICATION/USERID

Explanation: You cannot specify both a list and a terminal/application/user ID.

User Response: Specify just the list, or just a terminal/application/user ID.

EMTRM153 LIST DOES NOT EXIST - THE SPECIFIED LIST NAME DOES NOT EXIST ON THE VGBL DATASET

Explanation: The list name you specified cannot be found.

User Response: Make sure the list name is spelled correctly and that the list exists.

EMTRM154 LIST HAS NO ENTRIES - THE SPECIFIED LIST CONTAINS NO TERM/APPL/USERID ENTRIES

Explanation: The list you specified has no term/appl/user ID entries.

User Response: Specify a list that contains term/appl/user ID entries.

EMTRM155 INVALID TYPE VALUE - THE VALUE IN THE TYPE COLUMN MUST BE INCLUDE OR EXCLUDE

Explanation: The TYPE value you specified is invalid.

User Response: Use either INCLUDE or EXCLUDE.

EMTRM156 INVALID NAME VALUE - THE VALUE IN THE NAME COLUMN MUST BE PRESENT AND BE 8 CHARS OR LESS

Explanation: The NAME value you specified is invalid.

User Response: Specify a NAME that is 1 to 8 characters.

EMTRM157 INVALID DEFAULT VALUE - THE VALUE IN THE DEFAULT FIELD MUST BE INCLUDE OR EXCLUDE

Explanation: The DEFAULT value you specified is invalid.

User Response: Use either INCLUDE or EXCLUDE.

EMTRM158 INVALID COMMENT VALUE - THE VALUE IN THE COMMENT FIELD MUST BE YES, NO, OR CLEAR

Explanation: The COMMENT value you specified is invalid.

User Response: Use either YES, NO or CLEAR.

EMTRM159 MISSING REXX DATASET - THE REXX DATASET IS REQUIRED. ENTER A PDS NAME WITHOUT A MEMBER.

Explanation: You have not specified a REXX dataset.

User Response: Enter a PDS name without a member.

EMTRM160 MEMBER WITH REXX - DO NOT SUPPLY A MEMBER NAME WITH THE REXX DATASET

Explanation: You have specified a member name with the REXX dataset.

User Response: Remove the member name and retry.

EMTRM161 INVALID LOG DATASET - SUPPLY A SEQUENTIAL DATASET OR A PDS WITH A MEMBER NAME FOR THE LOG

Explanation: The dataset name you specified is not valid.

User Response: Check the spelling and make sure the dataset exists.

Page 114: Hiperstation Messages and Codes

3-38 Hiperstation Messages and Codes

EMTRM166 DUPLICATE ENTRY - The list name used already exists

Explanation: The list name you specified already exists.

User Response: Use a list name that does not currently exist.

EMTRM167 Cannot Access GR Req DS - Global Recording Dataset Allocation Failed

Explanation: Hiperstation was unable to allocate the Global Recording Request File.

User Response: Verify the dataset specified by the &XTRMGRDS parameter in the SQQFPENU member ETRMGPAR. If the dataset is correct and exists, verify that your user ID has update authority to the dataset.

EMTRM168 LIST NAME MISSING - SUPPLY A LIST NAME

Explanation: You have not specified a required list name.

User Response: Enter a list name in the required field.

EMTRM169 LIST TYPE INVALID - SUPPLY A LIST TYPE OF IN OR EX

Explanation: The list type you specified is invalid.

User Response: Retry using a list type of IN or EX.

EMTRM170 INVALID SELECTION - CHOOSE ONE OF THE ITEMS LISTED ON THE PANEL.

Explanation: The selection you specified is invalid.

User Response: Retry specifying one of the items listed on the panel.

EMTRM176 SUPPLY A SEQUENTIAL DATASET WITH NO MEMBER OR A PDSE WITH A MEMBER

Explanation: An existing sequential dataset has been supplied with a member name or an existing partitioned dataset (PDSE) has been supplied without a member name for the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, or TRACE print files. This is incorrect, because a sequential dataset must not have a member and a partitioned dataset must have a member.

User Response: For a sequential dataset, remove the member name or choose a new dataset. For a partitioned dataset, add a member name or choose a new dataset.

EMTRM177 WARNING: THIS IS A PDS! - DATASET IS A PARTITIONED DATASET (PDS), IT MUST BE A PDSE INSTEAD

Explanation: The dataset you specified is a PDS, not a PDSE.

User Response: Retry using a PDSE.

EMTRM179 COULD NOT ALLOCATE DATASET OR OBTAIN DSCB INFORMATION

Explanation: An existing dataset is migrated and could not be recalled or information about a dataset could not be obtained from the system catalog. This message appears for the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, or TRACE print files.

User Response: Choose another dataset to use or contact Compuware Customer Support.

EMTRM180 RECORD FORMAT (RECFM) MUST BE VARIABLE

Explanation: An existing dataset being used for the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, or TRACE is not the correct record format. The record format for print files must be V, VB, VA, or VBA.

User Response: Choose a new dataset to use for the print file.

EMTRM181 LOGICAL RECORD LENGTH (LRECL) IS TOO SMALL, USE LRECL=143

Explanation: An existing dataset being used for the JOURNAL, LOG, XLOG, RLOG, AUTODOC, SUMMARY, or TRACE has a logical record length that is too small. The logical record length for print files must be at least 143.

User Response: Choose a new dataset to use for the print file.

Page 115: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-39

EMTRM183 INVALID RANGE SPECIFIED - PLEASE ENTER RANGE OF NUMBERS. FOR EXAMPLE: 1-5,7,8

Explanation: The range you specified is invalid.

User Response: Use a range like 1-5,7,8,etc.

EMTRM184 TIMING OPTION INVALID - TIMING OPTIONS MUST BE NUMERIC

Explanation: The timing option you entered is invalid.

User Response: Retry using a numeric option.

EMTRM187 INVALID VALUE - WHEN HOUR IS 24, THIS VALUE MUST BE 00

Explanation: The value 24 is not valid.

User Response: Retry using 00 instead.

EMTRM189 PREMATURE SCRIPT TERMINATION, PORT TERMINATED

Explanation: Hiperstation for VTAM finished reading all of the script statements before the session between the Hiperstation for VTAM virtual terminal and the domain destination had ended.

User Response: Verify that the scripts for the GROUP contained a logoff sequence. Verify that the scripts for the group contained a logoff sequence or the scripts for the allocate/accept contained a deallocate sequence. Alternatively, check the transaction journal for an out-of-synch condition or the system log the APPC script connected to for additional messages.

EMTRM203 THE VALUE SPECIFIED BY LU62PFX IS NOT VALID

Explanation: The value set must have a length of between one and seven and must not be blank.

User Response: Correct the length or make it a useful name.

EMTRM204 THE VALUES SPECIFIED BY LU62PFX AND LU62SFX ARE NOT COMPATIBLE

Explanation: The length of the prefix and suffix are too long.

User Response: Reduce the length of one or both so that the total length is no more than eight.

EMTRM205 1ST FILTER MUST BE LIST - THE FIRST FILTER MUST BE A LIST IF THE SECOND FILTER SPECIFIED

Explanation: When the second filter is specified, the first filter must be a list.

User Response: Retry with the valid Global Record Manager List.

EMTRM207 LU NAME FOR HIPERSTATION IS ALREADY IN USE ELSEWHERE

Explanation: The LU name listed for the port is in use elsewhere.

User Response: Use a different name that is defined to VTAM.

EMTRM208 LU6.2 OPEN NO RESPONSE FAILURE

Explanation: While waiting for the FMH5, a time-out occurred.

User Response: If there was a forthcoming FMH5, then increase the NORESPTO parameter to a more acceptable value.

EMTRM209 LU6.2 CLOSE FAILURE

Explanation: During the close an error was encountered.

User Response: Refer to the status that follows for more error information.

EMTRM214 UNABLE TO OPEN INDEX.XML FOR PROCESSING

Explanation: The HFS File INDEX.XML was not found or is unavailable for your userid.

User Response: If you have never run a Search Report, this message is normal and is purely informational. If you have run a Search Report, verify with your installer that the HFSPATH is

Page 116: Hiperstation Messages and Codes

3-40 Hiperstation Messages and Codes

specified correctly and confirm that you have write and execute permissions to the 'archive' directory on this system.

EMTRM215 UNABLE TO READ DATA FROM INDEX.XML

Explanation: There was a problem reading the INDEX.XML for your userid.

User Response: Confirm that you have read, write, and execute permissions to your userid-specific archive directory.

EMTRM216 UNABLE TO OPEN TEMP_INDEX.XML FOR PROCESSING

Explanation: There was a problem creating a temporary copy of the INDEX.XML for your userid.

User Response: Confirm that you have read, write, and execute permissions to your userid-specific archive directory.

EMTRM217 HFSPATH VALUE IS MISSING, CONTACT YOUR INSTALLER

Explanation: The HFSPATH is not defined.

User Response: Contact your installer to verify that the HFSPATH has been properly defined in the ETRMGPAR member.

EMTRM218 HFSPATH IS NOT DEFINED PROPERLY, CONTACT YOUR INSTALLER

Explanation: The HFSPATH is not in a valid format.

User Response: Contact your installer to verify that the HFSPATH has been properly defined in the ETRMGPAR member. Reference the Mainframe Installation Guide for additional information on defining the HFSPATH parameter.

EMTRM219 VALID SELECTION CHARACTERS ARE Y, S, X, OR /

Explanation: An invalid character was entered on the Delete Confirmation pop-up window for Search Report Management.

User Response: If you wish to turn off delete confirmations, select the 'Permanently set delete confirmation off' option by entering a '/' next to it.

EMTRM221 UNKNOWN RECORD DATA TYPE FOUND

Explanation: The data type received by Hiperstation is not known.

EMTRM230 SCRIPT IS NOT VERSION 8 OR HIGHER

Explanation: A LU6.2 script is not a version 8 or higher.

User Response: Record the script using Hiperstation for Mainframe Servers at release 5.2 or higher. Do not attempt to just change the version number to 8. This can cause unpredictable results.

EMTRM231 SECOND "ALLOCATE" FOUND AFTER SCRIPT STARTED

Explanation: During playback, an ALLOCATE statement was found within the script.

User Response: Remove the ALLOCATE statement.

EMTRM232 "UNKNOWN" RECORD TYPE FOUND IN SCRIPT

Explanation: During playback, a record type was encountered that was not a valid LU6.2 statement.

User Response: Remove the statement.

EMTRM233 OUTBOUND OR INBOUND NOT FOUND IN SCRIPT

Explanation: For LU6.2 ACCEPT processing, the script does not contain an OUTBOUND or INBOUND statement.

User Response: Inspect the script and ensure that it is the correct one.

EMTRM234 SUCCESSFUL ALLOCATE NOT PROCESSED BEFORE VERB FOUND

Explanation: An APPC verb was found before a successful ALLOCATE has been processed.

Page 117: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-41

User Response: Inspect the script and correct.

EMTRM236 ALLOCATE/ACCEPT FOUND WITH TPNAME X‘06F1’

Explanation: An ALLOCATE or ACCEPT statement was found with a TPNAME of x‘06F1’. This ALLOCATE or ACCEPT is ignored for the playback.

User Response: Although not necessary, remove the ALLOCATE or ACCEPT.

EMTRM241 ERROR OPENING DETAIL FILE(S)

Explanation: During playback, an error was detected while opening the detail file.

User Response: Correct the condition and resubmit the playback.

EMTRM251 NORMAL RECORD LENGTHS NOT EQUAL

Explanation: The expected record length does not equal the actual record length received.

User Response: Correct the condition and resubmit the playback.

EMTRM252 RECORD TYPES ARE NOT THE SAME

Explanation: The expected record type does not match the actual record type received.

User Response: Correct the condition and resubmit the playback.

EMTRM253 MAP NAMES ARE NOT THE SAME LENGTH

Explanation: The expected map name length does not match the actual map name length received.

User Response: Correct the condition and resubmit the playback.

EMTRM254 MAP NAMES ARE NOT THE SAME

Explanation: The expected map name value does not match the actual map name value received.

User Response: Correct the condition and resubmit the playback.

EMTRM261 EXPEDITED RECORD LENGTHS ARE NOT EQUAL

Explanation: The expected record length does not match the actual record length received for expedited data.

User Response: Correct the condition and resubmit the playback.

EMTRM264 DEALLOCATE SENSE DATA NOT THE SAME

Explanation: The expected sense data does not match the actual sense data received for a deallocate.

User Response: Correct the condition and resubmit the playback.

EMTRM265 DEALLOCATE LOG DATA NOT EQUAL LENGTH

Explanation: The expected log data length does not match the actual log data length received for a deallocate.

User Response: Correct the condition and resubmit the playback.

EMTRM266 DEALLOCATE TYPE NOT THE SAME

Explanation: The expected data type does not match the actual data type received for a deallocate.

User Response: Correct the condition and resubmit the playback.

EMTRM267 SEND ERROR LOG DATA TYPES NOT THE SAME

Explanation: The expected log data type does not match the actual log data type received for a send error.

User Response: Correct the condition and resubmit the playback.

Page 118: Hiperstation Messages and Codes

3-42 Hiperstation Messages and Codes

EMTRM268 SEND ERROR LOG DATA LENGTHS NOT EQUAL

Explanation: The expected log data length does not match the actual log data length received for a send error.

User Response: Correct the condition and resubmit the playback.

EMTRM269 SEND ERROR SENSE DATA NOT EQUAL

Explanation: The expected sense data does not match the actual sense data received for a send error.

User Response: Correct the condition and resubmit the playback.

EMTRM270 EXPECTED: xxxxxxxx ACTUAL: xxxxxxxx

Explanation: The expected and actual sense data is shown here for the previous message. The values are in hex.

EMTRM271 EXPECTED: xxxxx ACTUAL: xxxxx

Explanation: The expected and actual length is shown here for the previous message.

EMTRM272 EXPECTED: xxxxxxxx ACTUAL: xxxxxxxx

Explanation: The expected and actual data type is shown here for the previous message.

EMTRM278 EXPECTED: xx--xx

Explanation: The expected data is shown here for the previous message.

EMTRM279 ACTUAL: xx--xx

Explanation: The actual data is shown here for the previous message.

EMTRM280 ETRMTRAI: TRACE TERMINATED - LOC(xx)

Explanation: Trace terminated due to a critical error detected by the system. The location of the error is indicated by the value of xx. All data up to the time of the error is written to the output datasets. The trace remains inactive for the duration of the batch run, or if the processing is online, until the user exits Hiperstation for VTAM and re-selects it via TSO.

User Response: Contact Compuware Customer Support and provide them with the location code and other pertinent information.

ET32LGET32LG101E CANNOT ALLOCATE DATASET dddd

Explanation: Dataset dddd is needed for the 3270 session log but either does not exist or is allocated to another user.

User Response: Ensure that the dataset exists and is not in use by others. See message ET32LG103E, which accompanies this message, for details on why the dataset could not be allocated.

ET32LG102E CANNOT FREE DATASET dddd

Explanation: Dataset dddd was used for the 3270 session log but now cannot be deallocated.

User Response: See message ET32LG103E, which accompanies this message, for details on why the dataset could not be deallocated.

ET32LG103E S99ERROR(eeee) S99INFO(iiii) S99ERSN(rrrr)

Explanation: A dynamic allocation failure occurred while allocating or freeing the 3270 session log dataset. This is typically because the dataset does not exist or is in use by another user.

User Response: Ensure that the dataset exists and is not in use by others. The meaning of eeee can be found in the IBM Authorized Assembler Services Guide in the S99ERROR Error Reason Codes section. The meaning of iiii can be found in the S99INFO Information Reason Codes

Page 119: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-43

section. The meaning of rrrr can be found in the S99ERSN Setting Up the Request Block Extension section.

ET32LG104E CANNOT OPEN DATASET dddd

Explanation: Dataset dddd is needed for the 3270 session log but cannot be opened. This is typically caused by Hiperstation not having security access to the dataset.

User Response: Check the Hiperstation script creation job log for any messages immediately preceding this message.

ET32LG106E BAD RECORD FORMAT FOR dddd, MUST BE V OR VB

Explanation: Dataset dddd is needed for the 3270 session log but cannot be used because its record format is not valid.

User Response: The dataset used for the 3270 session log must have a record format (RECFM) of V or VB (variable or variable-blocked).

ET32LG107E BAD RECORD LENGTH FOR dddd, MUST BE AT LEAST 80

Explanation: Dataset dddd is needed for the 3270 session log but cannot be used because its record length is not valid.

User Response: The dataset used for the 3270 session log must have a logical record length (LRECL) of at least 80.

ET32LG110E PDS DIRECTORY FOR dddd IS FULL

Explanation: Dataset dddd is being used for the 3270 session log but cannot be updated because its directory is full.

User Response: Ensure that the dataset being used has available space for additional members.

ET32LG111E CANNOT UPDATE dddd(mmmmmmmm)

Explanation: Dataset dddd and member mmmmmmmm is being used for the 3270 session log but cannot be updated. This is typically caused by the dataset running out of space.

User Response: See message ET32LG112E or ET32LG113, which accompanies this message, for details on why the dataset could not be updated.

ET32LG112E STOW MACRO RETURN AND REASON CODES(aaaa,bbbb)

Explanation: The member being used for the 3270 session log could not be saved in the dataset. This is typically caused by the dataset running out of space.

User Response: If the reason code, bbbb, is of the form xx37, there was not enough space available for the 3270 session log.

ET32LG113E ABEND CODE(xxxx)

Explanation: The 3270 session log could not written and saved in the dataset. This is typically caused by the dataset running out of space.

User Response: If the abend code, xxxx, is of the form xx37, there was not enough space available for the 3270 session log. Otherwise, check the IBM MVS or OS/390 System Codes manual for an explanation of the abend.

ET32LG114I SESSION LOG CREATED IN dddd(mmmm)

Explanation: This is an informational message indicating the successful creation of the 3270 session log.

ET32LG115E CANNOT ENQUEUE DATASET dddd

Explanation: The dataset needed for the 3270 session log cannot be used because it is in use by another user.

User Response: Ensure that the dataset is not in use by others.

Page 120: Hiperstation Messages and Codes

3-44 Hiperstation Messages and Codes

ETGRCRETGRCR101E GET UNIQUE MEMBER NAME FAILED

Explanation: An attempt to create a unique member name in the script dataset was not successful. A script will not be created.

User Response: Using the member prefix and suffix in the global recording request, a unique member name could not be created. Either choose member REPLACE, change the prefix, change the suffix, or delete or rename current members in the script dataset.

ETGRCR102E RECORDING DATASET IS NOT PARTITIONED

Explanation: An attempt to create a script was not successful because the script dataset is not partitioned. A script will not be created.

User Response: Update the script dataset name in the global recording request to list a PDS.

ETGRCR103E RECORDING DATASET IS NOT VARIABLE BLOCKED

Explanation: An attempt to create a script was not successful because the script dataset is not variable blocked. A script will not be created.

User Response: Update the script dataset name in the global recording request to list a variable blocked dataset.

ETGRCR104E OPEN FAILED FOR RECORDING DATASET

Explanation: An attempt to create a script was not successful because the script dataset could not be opened. A script will not be created.

User Response: Check the job log for the started task for related messages and contact Compuware Customer Support.

ETGRCR105E SECURITY DENIED ACCESS TO SCRIPT DATASET

Explanation: An attempt to create a script was not successful because the global recording started task did not have write access to the script dataset. A script will not be created.

User Response: Make the appropriate security changes.

ETGRCR106E RECORDING DATASET LRECL MUST BE LARGER THAN SCREEN WIDTH PLUS 8

Explanation: This message appears if you attempt to record a 3270 session to a dataset with a logical record length (LRECL) that is too small.

User Response: You must list a PDS with a variable-blocked (VB) record format and an LRECL of at least 88 for 3270 sessions.

ETGRDAETGRDA101I GR REQUEST #00007 DEACTIVATED

Explanation: This message indicates that a recording request has been deactivated. A deactivated request will not record any new 3270 sessions or APPC conversations.

User Response: A recording request is deactivated when a user issues the Stop or Force commands from the Global Recording Monitor Requests screen under ISPF. A request is also deactivated automatically if a security limitation prevents global recording from accessing a user’s dataset.

ETGRDA102I LU: llllllll APPL: aaaaaaaa USERID: uuuuuuuu

Explanation: Shows what logical unit (llllllll), application (aaaaaaaa), and user ID (uuuuuuuu) filters are associated with a 3270 recording request that is being deactivated.

User Response: Informational message. No user action necessary.

Page 121: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-45

ETGRDA103I SIDE A: netida.lunamea SIDE B: netidb.lunameb

Explanation: Shows the two application program (logical unit name) filters associated with an APPC recording request that is being deactivated.

User Response: Informational message. No user action necessary.

ETGRDA104I LOGMODE: llllllll USERID: uuuuuuuu

Explanation: Shows the logon mode name and user ID filters associated with an APPC recording request that is being deactivated.

User Response: Informational message. No user action necessary.

ETGRDA105I TP: tttttttt

Explanation: Shows the transaction program name filter that is associated with an APPC recording request that is being deactivated.

User Response: Informational message. No user action necessary.

ETGRDA106I

Explanation: This is a separator line displayed at the start of a group of deactivation messages for a recording request.

ETGRDA107I REPOSITORY: repository dataset name OWNER: user-ID

Explanation: REPOSITORY is the dataset associated with the request. Network traffic captured for this request was stored in this dataset. OWNER is the logon ID of the user who created or last updated this request.

User Response: Informational message. No user action necessary.

ETGRECETGREC101I SCRIPT ssssssss CREATED FOR LU cccccccc APPL aaaaaaaa

Explanation: The session between LU cccccccc and application aaaaaaaa has ended. Script ssssssss has been created and is located in the PDS listed on the global recording request.

ETGREC102E SCRIPT ssssssss CREATED FROM AN ABORTED GLOBAL RECORDING SESSION

Explanation: Script ssssssss has been created and is located in the PDS listed on the global recording request. The script is not complete due to lost recording buffers.

User Response: Contact Compuware Customer Support.

ETGREC103E SCRIPT ssssssss FAILED FOR LU cccccccc APPL aaaaaaaa RC=nnnn

Explanation: The session between LU cccccccc and application aaaaaaaa has ended. The script ssssssss could not be created due to an error condition. The error condition is indicated by RC=nnnn, where nnnn is:

Error User Response

04 - STOW macro failure. Contact Compuware Customer Support.

08 - No directory space in the PDS. Increase the size of the directory for the PDS.

12 - Not enough space in the PDS. Compress or enlarge the PDS.

16 - Enqueue failure. Contact the user who has control of the PDS.

20 - Member replace was set to no and a unique member name could not be created.

Change the member prefix in the request or delete existing members.

24 - Zero records recorded in script. Message ETGREC103I will be issued.

28 - The script creation task did not have write access to the script dataset.

Add the appropriate security rules to your site security system (RACF, ACF2, etc.)

Page 122: Hiperstation Messages and Codes

3-46 Hiperstation Messages and Codes

ETGREC104I SCRIPT ssssssss SKIPPED FOR LU cccccccc APPL aaaaaaaa

Explanation: The session between LU cccccccc and application aaaaaaaa has ended. The script ssssssss was not saved because the session consisted of control information only. This is normal for LUs connecting to TSO.

ETGREC106W ATTEMPT TO ARCHIVE SESSION FROM SCRIPT FAILURE WAS NOT SUCCESSFUL

Explanation: Script creation failed for the session. Refer to message ETGREC103E for a complete explanation. The session has been deleted.

User Response: Check the log for messages indicating the status of the archive file.

ETGRFRETGRFR106E FIX OR CHANGE DATASET, THEN ISSUE STOP(P) COMMAND

Explanation: An earlier error prevented the 3270 session log from being created. To prevent loss of the session logging data, it is kept in memory until it is successfully written to a dataset or until the CANCEL command is issued for the associated recording request.

User Response: Correct the problem with the 3270 session log dataset, which was identified by an earlier ET32LGxxx message, then issue the STOP command for the associated recording request.

ETGRMNETGRMN001I HIPERSTATION GLOBAL RECORDING ACTIVATED

Explanation: The global recording subtask has been activated.

ETGRMN011E UNKNOWN FAILURE IN ETRMGRST

Explanation: An attempt to activate a global recording request has failed. All segments in a repository may be full, and wrap was not selected.

User Response: Allocate a new or larger repository if they wish the request to be activated.

ETGRMN012E UNKNOWN FAILURE IN ETRMGRSP

Explanation: An attempt to stop a global recording request has failed.

User Response: Contact Compuware Customer Support.

ETGRMN015E MQSERIES OR TCP/IP TASK INACTIVE

Explanation: The started task did not activate the MQSeries and/or TCP/IP recording tasks, but an MQSeries and/or TCP/IP record request has tried to activate.

User Response: Make sure that the TCP/IP and/or MQ tasks are specified in GRPARMS and were successfully activated. To do this, check the started task sysout for message SVMAN391I to identify the capture types requested and message SVATH001I to identify which capture types were successfully activated.

32 - An unexpected abend was encountered in the DCB abend exit.

Contact Compuware Customer Support.

36 - Data stream error. Contact Compuware Customer Support.

40 - A PDS allocation error occurred. The PDS could be allocated when the global recording request was added or last updated. However, during the global recording process, an unknown event prevented the allocation.

Look for an application using the dataset as OLD instead of SHARE.

44 - Bad script; not a PDS, not correct RECFM, or LRECL is too short.

Error User Response

Page 123: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-47

ETGRMN016E START REQUEST NOT IN G/R REQ FILE. FROM:userid TYPE:type KEY=TIME STAMP-REPOSITORY FILE NAME*

Explanation: Because the GR request file defined to the ISPF interface is different than the GR request file defined to the Global Record started task, Global Recording was unable to add or restart the indicated recording request.

• FROM shows the TSO user ID that attempted to add or restart the request.• TYPE shows the type of the recording request: 3=3270, A=APPC, T=TCP/IP, and M=MQ.• KEY shows the time and date that the ADD or RESTART command was issued along with

the repository dataset name indicated in the request.

System Action: The ADD or RESTART command is ignored.

User Response: Ensure that the dataset name specified on the ATTACH,ETRMGRMN statement in the GRPARMS member your site is using, typically located in the samples library SQQFSAMP, is the same as the dataset name specified on the &XTRMGRDS parameter in the ETRMGPAR member of the panel library (SQQFPENU). Refer to the Hiperstation Installation and Configuration Guide for more information.

• If you modify the ATTACH statement, restart the Global Recorded started task to make the update take effect.

• If you modify the &XTRMGRDS parameter, exit Hiperstation to make the update take effect.

ETGRMN020E POST FR DATABASE UPDATE WITH NO REQUEST IGNORED

Explanation: The global recording subtask was posted by a user to perform a request, but the request chain was empty.

User Response: Contact Compuware Customer Support.

ETGRMN028E SVRQ REQUEST CODE IS NOT VALID

Explanation: The global recording subtask was posted by a user to perform a request, but the request was invalid.

User Response: Contact Compuware Customer Support.

ETGRMN029E SWITCH REQUEST FAILED. STOPPING THE REQUEST

Explanation: The last segment of the repository has been used, and wrap was not specified for the segmented repository.

User Response: No user action required.

ETGRMN030E SWITCH REQUEST FAILED. CURRENT REPOSITORY HAS NOT BEEN OPENED

Explanation: The current repository has not been opened and cannot be switched. This can happen if no new data has been written to the current repository since the global record request was activated.

User Response: Retry after session data is written to the repository.

ETGRMN031E SWITCH REQUEST FAILED. RECORDING TASK IS NOT ACTIVE

Explanation: Global recording is not active

User Response: Start the global recording task.

ETGRMN032E SWITCH REQUEST FAILED. REQUEST COULD NOT BE FOUND

Explanation: The global recording request associated with the segmented repository is not active.

User Response: Activate the global recording request.

ETGRMN040E MQ FILTER VALUES NOT AUTHORIZED FOR USERID: &USERID

Explanation: When global recording is restarted, security is rechecked. The owner is no longer authorized to make the request.

System Action: The global recording request is not started.

User Response: Ensure you have the proper authorization for your request.

Page 124: Hiperstation Messages and Codes

3-48 Hiperstation Messages and Codes

ETGRMN102E REQUIRED PARAMETER: GLOBAL RECORDING REQUEST FILE MISSING

Explanation: The global recording request file was not listed on the ATTACH command.

User Response: Message ETGRMN104I will be issued to the system console prompting the operator to reply with the global recording request file name.

ETGRMN103E ALLOCATION FAILED FOR HIPERSTATION GLOBAL RECORDING REQUEST FILE

Explanation: The global recording request listed could not be allocated.

User Response: Verify that the request file name was entered correctly or that the file exists and is cataloged.

ETGRMN104I ENTER GLOBAL RECORDING REQUEST FILE NAME OR CANCEL

Explanation: The global recording request file was not listed on the ATTACH command.

User Response: Reply with the global recording request file name or enter cancel to terminate the global recording subtask.

ETGRMN201I GLOBAL RECORDING IS SUSPENDED

Explanation: The Suspend recording option on the Administration Control Options screen has been selected. No new VTAM data will be recorded by the global recording address space until the selection character is removed from this option.

User Response: Informational message that appears in the global recording job log.

ETGRMN203I SCRIPT WRITING IS SUSPENDED

Explanation: The Suspend script creation option on the Administration Control Options screen has been selected. No new Hiperstation scripts will be created by the global recording address space until the selection character is removed from this option.

Scripts will still be created on demand for a particular recording request if the Force command is selected from the Global Recording Monitor Requests screen. Scripts will also be created for recording requests that list an “End time” if the request also specifies a “Record at end time” option.

User Response: Informational message that appears in the global recording job log.

ETGRMN204I SCRIPT WRITING IS RESUMED

Explanation: The Suspend script creation option on the Administration Control Options screen has been deselected. Hiperstation scripts will now be created for data that has already been recorded.

User Response: Informational message that appears in the global recording job log.

ETGRMN998I HIPERSTATION GLOBAL RECORDING SHUTDOWN ACKNOWLEDGED

Explanation: Either the global recording started task is being shutdown or the DETACH command was issued for the global recording subtask. The subtask is in termination processing.

ETGRMN999I HIPERSTATION GLOBAL RECORDING SHUTDOWN COMPLETE

Explanation: Either the global recording started task is being shutdown or the DETACH command was issued for the global recording subtask. The subtask is terminated.

ETGRPXETGRPX101I PIU EXIT CALLED FOR INITIALIZATION

Explanation: The global recording PIU exit has been activated.

ETGRPX102I PIU EXIT CALLED FOR TERMINATION

Explanation: The global recording PIU exit has been deactivated.

Page 125: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-49

ETGRPX103I GR INITIATED FOR REQUEST 00007

Explanation: The PIU exit has received the first PIU for an LU listed on an active Global Recording request. The LU is listed as cccccccc.

ETGRPX1041 SIDE A: netida.lunamea SIDE B: netidb.lunameb

Explanation: Informational message. Shows the two application programs (logical unit names) for which APPC recording has begun.

ETGRPX1051 LOGMODE: llllllll

Explanation: Informational message. Shows the logon mode name for which APPC recording has begun.

ETGRPX1061 TP: tttttttt

Explanation: Informational message. Shows the transaction program name for which APPC recording has begun.

ETGRPX1071

Explanation: This is a separator line displayed at the start of a group of initiation messages for a recording request.

ETGRPX108E NO CINIT/BIND INFORMATION FOR LU: XXXXXXXX MSG: XXXXXXXX

Explanation: For 3270 recording, certain information is required from the CINIT and BIND. The PIUs flow at the time the 3270 session begins.Either the session began prior to starting Hiperstation’s started task, or the checkpoint file (where the Hiperstation started task stores CINIT/BIND PIUs) has wrapped around.

Note: Session recording cannot be accomplished without the CINIT/BIND data.

User Response: If you suspect that the checkpoint file has wrapped around, reallocate the checkpoint file — increasing the space allocation in SAMPLIB member GRCKDEF.

ETGRPX109E NO CINIT/BIND INFORMATION FOR LU: XXXXXXXXXXXX MSG: XXXXXXXXXXXX

Explanation: For APPC recording, certain information is required from the CINIT and BIND. The PIUs flow at the time the APPC session begins.Either the session began prior to starting Hiperstation’s started task, or the checkpoint file (where the Hiperstation started task stores CINIT/BIND PIUs) has wrapped around.

Note: Session recording cannot be accomplished without the CINIT/BIND data. The ORIGIN and DEST information displayed are the VTAM LU6.2 subarea and element numbers for each partner.

User Response: If you suspect that the checkpoint file has wrapped around, reallocate the checkpoint file — increasing the space allocation in SAMPLIB member GRCKDEF.

ETGRPX111I BUILDING SESSION TRACKING TABLE STARTED

User Response: Informational message. No user action necessary.

ETGRPX112I BUILDING SESSION TRACKING TABLE COMPLETED TOTAL VLUI CREATED: X'00000000'

User Response: Informational message. No user action necessary.

ETGRPX113W ADDING VLUI ENTRY FAILED (CPOOL SHORTAGE) TOTAL VLUI IN CPOOL: X'xxxxxxxx'

Explanation: The SESSCNT parameter defined in the Global Record Start Up Parameter list is too small. A new VTAM session could not be registered. The current VLUI count is displayed in Hex.

User Response: Increase the value in the SESSCNT parameter, and then restart Global Recording.

Page 126: Hiperstation Messages and Codes

3-50 Hiperstation Messages and Codes

ETGRPX114W ADDING VLUI ENTRY FAILED (HASH ADD ERROR) TOTAL VLUI IN CPOOL: X'xxxxxxxx'

Explanation: The SESSCNT parameter defined in the Global Record Start Up Parameter list is too small or HASHLOAD parameter is too high, if it is specified. The new VTAM session could not be registered. The current VLUI count is displayed in Hex.

User Response: Contact Compuware Customer Support if the problem persists.

ETGRPX118W SENDING A REQUEST TO ETRMGRMN FAILED.

Explanation: An internal error occurred between global recording subtasks. An SVCDUMP will be produced and then Global Recording operation will be resumed.

User Response: Contact Compuware Customer Support if the problem persists and be prepared to submit the SVCDUMP for diagnosis, if requested.

ETGRPX119W INTERNAL ERROR FREEING A VSSS.

Explanation: An internal error occurred when freeing a VSSS. An SVCDUMP will be produced and then Global Recording operation will be resumed.

User Response: Contact Compuware Customer Support if the problem persists, and be prepared to submit the SVCDUMP for diagnosis, if requested.

ETGRPX120I BACKUP OF USERID TRACKING INFORMATION IN PROGRESS

User Response: Informational message. No user action necessary.

ETGRPX121I BACKUP OF USERID TRACKING INFORMATION COMPLETE

User Response: Informational message. No user action necessary.

ETGRPX122I RESTORE OF USERID TRACKING INFORMATION IN PROGRESS

User Response: Informational message. No user action necessary.

ETGRPX123I RESTORE OF USERID TRACKING INFORMATION COMPLETE

User Response: Informational message. No user action necessary.

ETGRPX124E ALLOCATION FAILED FOR HIPERSTATION GLOBAL RECORDING DATASET

Explanation: The Global Record started task could not allocate the request file.

User Response: Refer to the GRPARMS used to bring up the started task and verify that the dataset name defined by the ATTACH ETRMGRMN statement is correct.

ETGRPX125E UNABLE TO OBTAIN STORAGE FOR USERID TBL

Explanation: Not enough storage defined to use the MVS cell pool storage.

User Response: Increase the size of the MVS subpool. Refer to the MVS system log to find the associated GETMAIN error message, which contains the MVS subpool number.

ETGRPX126W TERMINATING OLD VSSS/VSBE/VLUI/VSSS

Explanation: An internal error occurred when processing a VSSS/VLUI.

User Response: Contact Compuware Customer Support if the problem persists and be prepared to submit the Global Record Started Task Log for diagnosis, if requested.

ETGRPX127W BUFFER SIZE MISCALCULATION

Explanation: An internal error occurred in Global Record buffer processing. An SVCDUMP will be produced and then Global Recording operation will resume.

User Response: Contact Compuware Customer Support if problem persists and be prepared to submit the SVCDUMP for diagnosis, if requested.

ETGRPX903 $QIO CALL FAILED

Explanation: A failure from a call to an I/O routine in the 3270 and APPC PIU exit occurred. One possible cause is that the ATTACH,TCPRCQIO statement in the GRPARMS initialization parameters for the Global Record started task may be missing. This statement was optional in releases 7.0 and 7.1, but is required in releases 7.2 and more current.

Page 127: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-51

User Response: Contact your systems programmer to add the ATTACH,TCPRCQIO statement to the GRPARMS initialization parameters for the Global Record started task. If the statement is already there, contact Compuware Customer Support.

ETGRSPETGRSP101I GR REQUEST 00007 TERMINATED

Explanation: A request is terminated after it has been de-activated and no sessions are still active for the request.

User Response: No new sessions with this LU will be recorded.

ETGRSP102I SIDE A: netida.lunamea SIDE B: netidb.lunameb

Explanation: Informational message. Shows the two application program (logical unit name) filters associated with an APPC recording request that is being terminated.

ETGRSP105I

Explanation: This is a separator line displayed at the start of a group of termination messages for a recording request.

ETGRSP106E FIX OR CHANGE DATASET, THEN REISSUE STOP(P) COMMAND

Explanation: An earlier error prevented the 3270 session log from being created. To prevent loss of the session logging data, it is kept in memory until it is successfully written to a dataset or until the CANCEL command is issued for the associated recording request.

User Response: Correct the problem with the 3270 session log dataset, which was identified by an earlier ET32LGxxx message, then issue the STOP command for the associated recording request.

ETGRSP107I REPOSITORY: repository dataset name OWNER: user-ID

Explanation: REPOSITORY is the dataset associated with the request. Network traffic captured for this request was stored in this dataset. OWNER is the logon ID of the user who created or last updated this request.

User Response: Informational message. No user action necessary.

ETGRSTETGRST101I GR REQUEST 00009 ACTIVATED

Explanation: The global recording request for the chosen LU is activated.

User Response: New sessions with this LU will be recorded.

ETGRST102I SIDE A: netida.lunamea SIDE B: netidb.lunameb

Explanation: Informational message. Shows the two application program (logical unit name) filters associated with an APPC recording request that is being activated.

ETGRST103I LOGMODE: llllllll USERID: uuuuuuuu

Explanation: Informational message. Shows the logon mode name and user ID filters associated with an APPC recording request that is being activated.

ETGRST104I TP: tttttttt

Explanation: Informational message. Shows the transaction program name filter that is associated with an APPC recording request that is being activated.

ETGRST105I

Explanation: This is a separator line displayed at the start of a group of activation messages for a recording request.

Page 128: Hiperstation Messages and Codes

3-52 Hiperstation Messages and Codes

ETGRST106I REQUEST OWNER: user-ID REPOSITORY: repository dataset name

Explanation: REQUEST OWNER is the logon ID of the user who created or last updated this request. REPOSITORY is the dataset associated with the request. Network traffic captured for this request was stored in this dataset.

User Response: Informational message. No user action necessary.

ETGRST106W WHEN "LOGON ONLY = N", SUPPLY FULL TERMINAL LU NAME AND EITHER FULL APPLICATION NAME OR * BY ITSELF: cccccccc

Explanation: A global recording request listed “Record from logon only ===> N” exists and one of the following is true:

• The Terminal LU field is blank or contains the wildcard character (*)• The Terminal LU or application is not a logical unit in this VTAM system• More than one application field contains a partial name followed by the wildcard

character (*).

The cccccccc value shows the field value that will prevent an existing 3270 session from being recorded.

User Response: Recording requests that list “Record from logon only ===> N” will always be activated by global recording, but will only record data for an existing session if the terminal LU name is a full logical unit name (no wildcard character) and the application name is either a full name, a blank, or a single wildcard character. When this message is present, existing 3270 sessions that appear to match the field values will not be recorded. New 3270 sessions that begin after this time will be recorded.

To record an existing session, supply a full Terminal LU name and either a full name, a blank, or a single wildcard character for the application name.

ETGRST107W NAU ADDRESS CANNOT BE DETERMINED WHEN “term, appl, userid list” USED

Explanation: NAU stands for Network Accessible Unit. This error occurs on returning from the Global Recording ADD/UPDATE Requests screen when the “Record from logon only ===> N” is true. If this message appears, the recording request may or may not be activated. If the user is currently logged on, or recently logged on and then logged off, the request is activated even if the warning message appears.

User Response: If the request activates correctly, then ignore the message. If the request does not activate, cancel the request and specify a new request with out the listname option by specifying a single userid at the top of the panel only (no listname).

ETINETINIT101E REXX INITIALIZATION FAILED, RC=xxxx REASON=yyyy

Explanation: Initialization of a REXX environment was not successful. The return code (xxxx) and the reason code (yyyy) are from IRXINIT in hexadecimal format.

User Response: See IBM’s REXX Reference Manual for an explanation of the return code (xxxx) and reason code (yyyy) or call Compuware Customer Support.

ETPOETPO621E PROCESSING ERROR: xxxxxxxx

Explanation: An error has been detected during the APPC (LU6.2) script playback. xxxxxxxx is another Hiperstation message ID.

User Response: Refer to message xxxxxxxx in the Hiperstation Messages and Codes guide, correct the error, and rerun the playback job.

ETPO622E ACB OPEN ERROR, RC: cccc FBK2: ffff LU: xxxxxxxx ACB CLOSE ERROR, RC: cccc FBK2: ffff LU: xxxxxxxx SETLOGON1 ERROR, RC: cccc FBK2: ffff LU: xxxxxxxx

Page 129: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-53

SETLOGON2 ERROR, RC: cccc FBK2: ffff LU: xxxxxxxx USERVAR ERROR, RC: cccc FBK2: ffff LU: xxxxxxxx

Explanation: An error was detected during the open or close of an LU6.2 APPL. If the message indicates SETLOGON1, there was a failure defining the generic LU name via the SETLOGON OPTCD=GNAMEADD. If the message indicates SETLOGON2, there was a failure during the SETLOGON OPTCD=START. If the message indicates USERVAR, there was a failure issuing the SENDCMD macro to VTAM to modify the USERVAR. The command issued was "F xxx,USERVAR,APPC=YES,ID=yyy,VALUE=zzz", where xxx is the job name of VTAM, yyy is the alias LU name and zzz is the real LU name.

User Response: The return and feedback codes are hex values. Review the section of IBM’s z/OS Communications Server: SNA Programming manual that describes the Open macroinstruction for an explanation of the return code (cccc) and feedback code (ffff), or call Compuware Customer Support.

ETPO623E AL62 REQUEST ERROR, STATUS: ssss

Explanation: An undocumented ETRMAL62 request code (ssss) has been detected.

User Response: Call Compuware Customer Support for an explanation of this code.

ETPO624E CNOS ERROR, R15: aa R0: bb RTNCD: cc FDB2: dd RCPRI: eeee RCSEC: ffff

Explanation: During the open process, a CNOS error was detected. The R15, R0, RTNCD, FDB2, RCPRI, and RCSEC data is provided to help determine the error.

User Response: Refer to the appropriate VTAM manuals and make necessary corrections for the ALLOCATE.

ETPO625I LU FOR HIPERSTATION IS BUSY ELSEWHERE: xxxxxxxx

Explanation: The designated LU is busy and cannot be used at this time.

User Response: Wait for the LU to become available or use another LU.

ETPO626E DATA NOT FOUND FOR OPERATION: oo--oo

Explanation: A script record type code has been encountered that requires data but no data has been found.

User Response: Inspect the script and provide data for the record type via the LABEL or CONTENT keyword.

ETPO627E PROCESSING SCRIPT: xxxxxxx STATEMENT: xxxxx

Explanation: An error has been found during script processing. This is the statement number that caused the error. This number may not be exact. It may point to a CONTENT statement. If it does, the statement in error is the one associated with the CONTENT statement.

ETPO628E xxxxxxx not responsive for operation: oo--oo

Explanation: The xxxxxxxx is either ‘request’ or ‘partner’. The operation oo--oo is the type of request made. If it is a request, then a request was made to the LU62 component of Hiperstation for Mainframe Servers and no response was received. If it is a partner, no response was received from the LU62 partner. The response period is determined from the NORESPTO keyword.

User Response: If the partner was active at the time of this message, consider increasing the NORESPTO value to one more representative of the time it could take to receive a response from the partner.

ETPO629I LU62 STATUS, R15: aa R0: bb RTNCD: cc FDB2: dd RCPRI: eeee RCSEC: ffff

Explanation: During processing, a situation was encountered where the R15, R0, RTNCD, FDB2, RCPRI and RCSEC data may help to determine the error.

User Response: Refer to the appropriate VTAM manuals and make necessary corrections for the ALLOCATE.

Page 130: Hiperstation Messages and Codes

3-54 Hiperstation Messages and Codes

ETPORTETPORT1E VTAM INITIALIZATION ERROR: cccccccc

Explanation: Hiperstation could not establish a session with a virtual terminal. The message cccccccc can be found in the Hiperstation message library (ISPMLIB).

User Response: In unattended playback mode, the message cccccccc detail is not issued. Execute script playback using Domain Traveler to get further diagnostics. The message cccccccc can be found in the Hiperstation Messages and Codes guide. Ensure that the virtual terminal major node has been active. Also, ensure that the prefix statement on the control parameter has the correct prefix for the virtual terminals.

ETPRTSETPRTS101E DYNAMIC ALLOCATION ERROR RC=

Explanation: Error allocating print dataset during batch processing.

User Response: Correct dataset error and rerun.

ETPRTS102E DYNAMIC ALLOCATION ERROR RC=

Explanation: Error allocating print dataset during online processing.

User Response: Correct dataset error and rerun.

ETRMETRM32IS UNKNOWN COMMAND DETECTED

Explanation: This message is displayed on the Job log if LU0 data is attempted to be created into a formatted script. It occurs due to a format conflict between LU0 commands and 3270 commands.

User Response: LU0 scripts must be created as Unformatted. Change this setting and rerun Script Create.

ETRM9000 SHORT ON STORAGE PROCESSING

Explanation: Hiperstation ran out of cache space during processing.

User Response: Increase cache size in EHSDFLT.

ETRMFETRMF000 ENTRIES REQUIRED - IF ONE OF THE LUW ENTRIES ARE REQUIRED, THEN ALL MUST BE ENTERED

Explanation: You have not specified all LUW entries.

User Response: You must enter all LUW entries.

ETRMF004 INVALID MEMBER NAME

Explanation: The member name you entered is invalid.

User Response: Make sure the member name is spelled correctly and exists.

ETRMF006 INVALID DSN

Explanation: The dataset name you entered is invalid.

User Response: Make sure the dataset name is spelled correctly and exists.

Page 131: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-55

ETRMF008 SCRIPT DATASET NOT FOUND

Explanation: The script dataset name you entered could not be found.

User Response: Make sure the dataset name is spelled correctly and exists.

ETRMF009 VALUE MUST BE NUMERIC

Explanation: The value you entered is not numeric.

User Response: Retry using a numeric value.

ETRMF010 VALUE MUST BE < 8 - THE SUFFIX MUST BE A NUMBER FROM 1 TO 7

Explanation: The value you entered was too large.

User Response: Use a number from 1 to 7.

ETRMF011 VALUE MUST BE "Y" OR "N"

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

ETRMF012 INVALID NETWORK NAME - NETWORK NAMES MUST BE OF THE FORM LUname OR netid.LUname

Explanation: The network name you specified is invalid.

User Response: Use the form LUname or netid.LUname.

ETRMF014 MEMBER NAME IS REQUIRED - WHEN THE STATEMENT DATASET IS A PDS, A MEMBER MUST BE SPECIFIED

Explanation: You have not specified a member name for the PDS.

User Response: Enter a member name in the field.

ETRMF017 INVALID TIMESTAMP - TIMESTAMP MUST BE IN THE FORM YYYY/MM/DD_HH:MM:SS.nnnnnn

Explanation: The timestamp you specified is invalid.

User Response: Use the form YYYY/MM/DD_HH:MM:SS.nnnnnn.

ETRMF027 REPEAT AND TERM MUST = 1 - DUBBING IS VALID ONLY WHEN THE NUMBER OF TERMinals AND REPEAT ARE 1

Explanation: You cannot dub with your current REPEAT and TERM values.

User Response: Change the REPEAT and TERM values to 1 and retry.

ETRMF029 PDS IS REQUIRED - THE SCRIPT DATASET MUST BE A PDS

Explanation: You have not specified a PDS for the script dataset.

User Response: Specify a PDS and try again.

ETRMF033 CONFLICTING ENTRIES - THINK TIME MINUTES AND SECONDS, AND PERCENT MAY NOT BOTH BE ENTERED

Explanation: You are using a think time AND a percent, which is not allowed.

User Response: Use either a think time in minutes and seconds, OR a percent value.

ETRMFEITETRMFEIT01 Could Not Locate Hiperstation Load Library. Reason is: nnnnn

Explanation: The Hiperstation load library could not be identified. Processing will continue.

User Response: The created JCL must have the Hiperstation load library added as a STEPLIB before submitting the Unattended Playback job.

Page 132: Hiperstation Messages and Codes

3-56 Hiperstation Messages and Codes

ETRMGRPXETRMGRPX20 aaaaaaaa bbbbbbbb cccccccc dddddddd

Explanation: This is a diagnostic message produced when Hiperstation is unable to locate VTAM session information for a 3270 or APPC datastream. The information displayed is the contents of an internal Hiperstation control block.

User Response: If you are not recording the 3270 sessions or APPC conversations that you believe you should be recording, based on your active recording requests, contact Compuware Customer Support. In many cases, the appearance of this message does not indicate a problem.

ETRMIETRMI002I EHSDFLT NOT FOUND

Explanation: EHSDFLT was not found in a load library defined as JOBLIB, STEPLIB, or ISPLLIB.

System Action: Follow Hiperstation Installation and Configuration Guide instructions on generating the EHSDFLT load module. Ensure it is placed in a load library defined as JOBLIB, STEPLIB, or ISPLLIB, then rerun.

ETRMI003I EHSDFLT NOT AUTHORIZED

Explanation: EHSDFLT is not authorized, or the library is not authorized

System Action: Follow Hiperstation Installation and Configuration Guide instructions on generating the EHSDFLT load module. Ensure it is placed in a load library defined as JOBLIB, STEPLIB, or ISPLLIB, then rerun.

ETRMOETRMO620 INVALID SPACE UNITS - MUST BE BLKS, TRKS, CYLS, KB, MB OR BYTES

Explanation: The space units you specified are invalid.

User Response: Retry using BLKS, TRKS, CYLS, KB, MB or BYTES.

ETRMO621 INVALID UNIT - GENERIC UNIT MUST BE BLANK IF VOLUME SERIAL IS SPECIFIED

Explanation: The unit you have specified is invalid.

User Response: Take out the unit if you have a volume serial already specified.

ETRMRACFETRMRACF-001E XTRMDFLT(EFHDFLT TABLE ADDRESS) IS ZERO, PROGAM WILL BE TERMINATED WITH ABEND CODE 100

Explanation: EHSDFLT table was not loaded properly. Program will abend with abend code 100.

User Response: Contact Compuware Customer Support.

ETRMRR1ETRMRR1-0001E Error Making Root Directory: <root> RC: <rc> 'Errno:' <Errno> 'Errnojr:' <Errnojr>.

Explanation: The root directory required to store the Search criteria HFS files could not be created.

Page 133: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-57

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS root directory could not be created.

ETRMRR1-0002E Error on Allocate of Filter PDSE <PDSE_name> Return code: <rc>

Explanation: The PDSE required to hold the Search Criteria files cannot be allocated.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned code to investigate why the named PDSE could not be allocated. Examine the TEMP* dataset definition parameters and the SRCHPRF dataset name prefix defined in the ETRMGPAR panel member. Compare these values with local site standards.

ETRMRR1-0003E Error Reading Directory: <rootpath> RC: <rc> 'Errno:' <Errno> 'Errnojr:' <Errnojr>.

Explanation: The HFS directory containing any previously created Search Criteria files cannot be read.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS directory could not be accessed.

ETRMRR1-0004E Error Reading Search Criteria File: <filepath> RC: <rc> 'Errno:' <Errno> 'Errnojr:' <Errnojr>.

Explanation: The named HFS file, which contains a previously entered set of Search criteria, cannot be read.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be accessed.

ETRMRR1-0005E Error Getting Load Dataset name, Reason(<reason_code>). Load DD Name: <DD_name>

Explanation: The passed DD name for the Hiperstation for VTAM load library could not be utilized by the LISTDSI function.

System Action: Creation of Archive Search request terminates.

User Response: Contact Compuware Customer Support.

ETRMRR1-0006E Error Getting EXEC Dataset name, Reason(<reason_code>). Load DD Name: <DD_name>

Explanation: The passed DD name for the Hiperstation for VTAM REXX EXEC library could not be utilized by the LISTDSI function.

System Action: Creation of Archive Search request terminates.

User Response: Contact Compuware Customer Support.

ETRMRR1-0007E Error on SYSDSN of Filter PDSE: <PDSE_name>

Explanation: The Script Criteria PDSE name caused an error in the REXX SYSDSN function.

System Action: Creation of Archive Search request terminates.

User Response: Contact Compuware Customer Support.

ETRMRR1-0008E Archive directory does not exist in path: <archive_path> RC: <rc> Errno: <errno> Errnojr: <errnojr>

Explanation: The archive directory used to store HFS files and reports for Archive Search has not been defined.

System Action: Creation of Archive Search request terminates.

User Response: Contact the local product installer and reference the Hiperstation Installation and Configuration Guide for details on how to create the archive directory appropriately.

Page 134: Hiperstation Messages and Codes

3-58 Hiperstation Messages and Codes

ETRMRR1-0011E Error Making Global Root Directory: <root> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The global root directory required to store the shared Search criteria HFS files could not be created.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS global root directory could not be created.

ETRMRR1-0012E Error Reading Global Directory: <rootpath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The HFS directory containing any previously created Global Search Criteria files cannot be read.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS directory could not be accessed.

ETRMRR1-0013E Error Reading Global Criteria File: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The HFS file containing the Global Search Criteria could not be read.

System Action: Creation of Archive Search request terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be accessed.

ETRMRR1-0014E Error Unlinking Filter File: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The named HFS file containing the Global Search Criteria could not be deleted.

System Action: Processing of Archive Search filter member request terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be deleted.

ETRMRR1-0015E Error Unlinking Filter File: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The named HFS file containing Local Search Criteria could not be deleted.

System Action: Processing of Archive Search filter member request terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be deleted.

ETRMRR1-0016E Error Opening Search Criteria File: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The named HFS file could not be opened for member statistics calculation.

System Action: Processing of HFS file statistics terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be opened.

ETRMRR1-0017E Error Reading Search Criteria fstat: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The named HFS file could not be read for member statistics calculation.

System Action: Processing of HFS file statistics terminates.

User Response: Use the returned codes to investigate why the named HFS file could not be read.

ETRMRR1-0018E Error in gmtime for Create Time: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The USS C function gmtime() failed in filter member statistics function.

System Action: Processing of HFS file statistics terminates.

Page 135: Hiperstation Messages and Codes

Hiperstation Messages: EHSD through ETTERM 3-59

User Response: Use the returned codes to investigate why the gmtime() command failed. If the problem persists contact Compuware Customer Support.

ETRMRR1-0019E Error in gmtime for Modified Time: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The USS C function gmtime() failed in filter member statistics function.

System Action: Processing of HFS file statistics terminates.

User Response: Use the returned codes to investigate why the gmtime() command failed. If the problem persists contact Compuware Customer Support.

ETRMRR1-0020E Error in getpwuid: <filepath> RC: <rc> Errno: <Errno> Errnojr: <Errnojr>.

Explanation: The USS C function getpwuid() failed in filter member statistics function.

System Action: Processing of HFS file statistics terminates.

User Response: Use the returned codes to investigate why the getpwuid() command failed. Generally:

– A RACF return code 4 means that for a search, the GID, UID, group name, or user ID is not defined.

– A RACF return code 8 means that a group name or user ID is not defined.– A RACF return code 12 means that there was an internal error during RACF processing.– A RACF return code 16 means that recovery could not be established.– A RACF return code 20 means that the current group or user is incompletely defined.

If the problem persists contact Compuware Customer Support.

ETRMTETRMTRXA ATTRIBUTE TRANSLATION ERROR ATTR: xxxxxxxx

Explanation: The attributes represented by xxxxxxxx could not be translated.

User Response: Contact Compuware Customer Support.

ETRMTS0I UNKNOWN AID DETECTED

Explanation: The attention identifier on the inbound data stream was not valid.

User Response: Contact Compuware Customer Support.

ETRMVTAMETRMVTAM SYNAD ENTERED RETURN CODE=xxx, FDBK=yy ETRMVTAM LERAD Entered Return Code=xx, FDBK2=yy

Explanation: The SYNAD or LERAD exit for the Hiperstation ACB was entered.

User Response: Contact Compuware Customer Support.

ETTERMETTERM101E REXX TERMINATION FAILED, RC=xxxx

Explanation: Termination of a REXX environment was not successful.

User Response: See IBM’s REXX Reference Manual for an explanation of the Return Code (xxxx) or call Compuware Customer Support.

Page 136: Hiperstation Messages and Codes

3-60 Hiperstation Messages and Codes

Page 137: Hiperstation Messages and Codes

4-1

Chapter 4.

4Hiperstation Messages: HSPFE through RGSTRYGN Chap 4

The chapter explains messages with prefix HSPFE through prefix RGSTRYGN and, if applicable, provides response actions you can take to resolve the issue causing the message. Messages are listed in alpha-numeric order and grouped by prefix. Use the “Contents” to help you find the message information you need.

HSPFEHSPFE800 Unable to allocate the tables dataset userid.HIPER.TABLES

Explanation: The tables dataset does not exist.

User Response: Ensure permissions allow userid.HIPER.TABLES to be allocated.

HSPFE801 The Profile has been saved.

Explanation: The profile has been saved into the Profile Dataset.

User Response: Informational message. No user action necessary.

HSPFE802 The Site Profile dataset is not specified in ETRMGPAR.

Explanation: The parameter QFPRFDSN in panel ETRMGPAR has not been properly set.

User Response: Contact the Product Installer to correct the parameter setting.

HSPFE803 The Default Profile from the Site Profile dataset is being used

Explanation: The Default Profile is in use because a personal one was not specified.

User Response: Informational message. No user action necessary.

HSPFE804 The filter line has been moved

Explanation: The specified filter line has been moved to the requested location.

User Response: Informational message. No user action necessary.

HSPFE805 The fetch for ISPLINK failed

Explanation: The program could not start ISPLINK.

User Response: Ensure the program has proper security permissions.

HSPFE806 Profile dataset &HSDSN or member HSMEM does not exist

Explanation: The profile dataset and member names cannot be found.

User Response: Enter an existing dataset/member combination.

HSPFE807 The filter line has been copied

Explanation: The specified filer line has been copied.

User Response: Informational message. No user action necessary.

HSPFE808 The profile has been copied

Explanation: The specified profile has been copied into the new name.

User Response: Informational message. No user action necessary.

HSPFE810 Only one line command at a time is supported

Explanation: Multiple line commands are not supported.

Page 138: Hiperstation Messages and Codes

4-2 Hiperstation Messages and Codes

User Response: Specify one line command at a time.

HSPFE811 Select another Profile dataset

Explanation: The selected dataset is the same as the site profile name.

User Response: Choose another name for your profile dataset.

HSPFE812 You did not select a profile. Reverting to previous one.

Explanation: The previously used Profile is being used for this session.

User Response: Informational message. No user action necessary.

HSPFE813 Error creating a USER Profile PDS - it already exists

Explanation: The system is trying to allocate a dataset that already exists.

User Response: Choose another name to allocate a fresh dataset.

HSPFE814 Error creating your new Profile dataset.

Explanation: There was an error in creating a new Profile dataset.

User Response: Make sure the value specified for the Site Profile Dataset in parameter QFPRFDSN and the value specified for the default profile member in parameter QFPRFDEF are valid. Also, make sure the user has the proper security authority to access the Site Profile Dataset.

HSPFE815 Value must be in the range specified.

Explanation: The value specified in outside of the allowable range.

User Response: Specify a value that is within the acceptable range.

HSPFE816 The profile member name is already in the Profile dataset.

Explanation: The profile has been saved into the Profile Dataset.

User Response: Informational message. No user action necessary.

HSPFE817 An error occurred when allocating the Profile XML file

Explanation: The profile XML file could not be allocated.

User Response: If the problem persists, contact Customer Support.

HSPFE818 An error occurred when opening the Profile XML file

Explanation: The profile XML file could not be opened.

User Response: If the problem persists, contact Customer Support.

HSPFE819 The COPY request failed. Cannot read source Profile

Explanation: A read error occurred during a copy request.

User Response: If the problem persists, contact Customer Support.

HSPFE820 An error occurred when closing the Profile XML file

Explanation: A system error occurred during a close request.

User Response: If the problem persists, contact Customer Support.

HSPFE821 The requested action is cancelled

Explanation: The requested action has been cancelled.

User Response: Informational message. No user action necessary.

HSPFE822 The request failed; The file may be in use by another user

Explanation: The request attempted to access a file which is currently in use.

User Response: Attempt the request after the file has been freed.

Page 139: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-3

HSPFE823 Table &FILTABLE is in use or is not allocated

Explanation: The table file could not be accessed.

User Response: Ensure the file is not in use and that it exists.

HSPFE824 The requested new name already exists, or the file is in use.

Explanation: The new name specified already exists in the Profile Dataset or the Profile Dataset is in use by another user.

User Response: Specify a different profile name and make sure the dataset is not in use by another user.

HSPFE825 The Profile was successfully renamed

Explanation: The profile has been renamed.

User Response: Informational message. No user action necessary.

HSPFE826 An error occurred while obtaining status of table

Explanation: A system error occurred during a status request.

User Response: If the problem persists, contact Customer Support.

HSPFE827 An error occurred while opening ISPF table

Explanation: The ISPF table could not be opened.

User Response: If the error persists, contact Customer Support.

HSPFE828 An error occurred on table SKIP instruction

Explanation: A skip request could not be completed.

User Response: If the error persists, contact Customer Support.

HSPFE829 The requested Profile has been deleted

Explanation: The profile has been deleted.

User Response: Informational message. No user action necessary.

HSPFE830 The ''<'' character is not allowed.

Explanation: The specified character is invalid.

User Response: Do not use the "<" character in this situation.

HSPFE831 No match was found for tag &TAG in table &TABLE

Explanation: A closing XML tag was found with no matching open tag.

User Response: The tables file could be corrupted. Contact Customer Support.

HSPFE832 The &HSTYPE profile dataset does not exist or cannot be opened

Explanation: The profile dataset specified is invalid.

User Response: Enter a valid profile dataset name.

HSPFE833 Primary command is invalid

Explanation: The primary command is invalid.

User Response: Use one of the listed primary commands.

HSPFE834 Line Commands B, A, C, M, D, I and R are valid on this screen.

Explanation: Only the listed line commands are valid.

User Response: Use one of the listed Line Commands.

HSPFE835 The Profile has NOT been modified due to a RACF violation

Explanation: You do not have RACF permission to modify the profile dataset.

User Response: Contact your RACF administrator to get modify permissions.

Page 140: Hiperstation Messages and Codes

4-4 Hiperstation Messages and Codes

HSPFE836 Your Profile PDS/E dataset has been created and populated.

Explanation: The profile dataset has been created.

User Response: Informational message. No user action necessary.

HSPFE837 The COPY request failed. Dataset allocated to another job

Explanation: A COPY could not be completed because the dataset is in use.

User Response: Try again once the other job has completed and the dataset is free.

HSPFE838 You must specify a Profile name

Explanation: The profile name is blank.

User Response: Enter a valid profile name.

HSPFE839 You must specify a valid profile name and dataset to edit'

Explanation: The dataset and member names are blank.

User Response: Enter a valid dataset/member combination to edit.

HSPFE840 An attempt to read the profile directory has failed

Explanation: A system error occurred during a directory read attempt.

User Response: If the error persists, contact Customer Support.

HSPFE843 Use only the line commands listed on the panel

Explanation: You have used an invalid line command

User Response: Select one of the line commands listed on the panel to execute.

ICMSGICMSG000 Entries required

Explanation: If one of the LUW entries are required, then all must be entered.

User Response: Make sure all LUW entries have been entered.

ICMSG001 Invalid command

Explanation: The command entered is not a valid primary command.

User Response: Enter a valid primary command.

ICMSG002 Invalid Dataset Name

Explanation: The Install library dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG003 Invalid Dataset Name

Explanation: The Install log library dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG004 Invalid Dataset Name

Explanation: The Global SMP log dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG005 Invalid Dataset Name

Explanation: The Global SMPPTS dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG006 Invalid Dataset Name

Explanation: The Distribution zone log dataset name is not a valid dataset name.

Page 141: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-5

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG007 Invalid Dataset Name

Explanation: The Target zone log dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG008 Invalid Dataset Name

Explanation: The Target zone SMPMTS dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG009 Invalid Dataset Name

Explanation: The Target zone SMSCDS dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG010 Invalid Dataset Name

Explanation: The Target zone SMSSTS dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG011 Invalid Dataset Name

Explanation: The Target zone SMSLTS dataset name is not a valid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG012 Invalid HLQ

Explanation: Invalid high-level qualifier specification for Language Environment datasets.

User Response: Make sure the high-level qualifier for these datasets is spelled correctly and the high-level qualifier exists.

ICMSG013 Invalid Directory

Explanation: A valid HFS path name was not specified.

User Response: Make sure the HFS path name is spelled correctly and the correct path name is used.

ICMSG014 LE dataset not found

Explanation: Language environment dataset was not found.

User Response: Make sure the language environment dataset name is spelled correctly and the dataset exists.

ICMSG015 Dataset not found

Explanation: Install Library dataset not found.

User Response: Make sure the install library dataset name is spelled correctly and the dataset exists.

ICMSG016 Allocate error

Explanation: Error allocating the install log library.

User Response: Make sure the install log library name is spelled correctly and/or allocate the library again.

ICMSG017 Update error

Explanation: An update error occurred.

User Response: Call Help Desk with message.

ICMSG018 Option disabled

Explanation: Option disabled. This option was not selected to be installed.

User Response: Return to Select Products & Features to install panel and select desired option.

Page 142: Hiperstation Messages and Codes

4-6 Hiperstation Messages and Codes

ICMSG019 Environment not built

Explanation: The environment has not been build.

User Response: You must complete Option 1, "Build Environment" before performing Installation and Customization tasks.

ICMSG020 The install jobs and sample members have been generated into the listed file.

Explanation: Guided install members have been generated.

User Response: Informational message. No user action necessary.

ICMSG021 Error generating install members

Explanation: 'The install job generator encountered an error.

User Response: Review the messages in the listed install log file, member INSTLOG, for details.

ICMSG022 &qfmemnam not found

Explanation: Install job &qfmemnam not found in install dataset &qfinstlb. The actual job and member names will appear in the message on your screen.

User Response: Ensure that Option 1 (Create JCL Members) or submit installation jobs panel has been executed.

ICMSG023 &qfmemnam submitted

Explanation: &qfsubmsg

User Response: Informational message. No user action necessary.

ICMSG024 LE dataset not found

Explanation: Language environment dataset not found.

User Response: Make sure the language environment dataset name is spelled correctly and the dataset exists.

ICMSG025 Dataset not found

Explanation: Install Library dataset not found.

User Response: Make sure the install library dataset name is spelled correctly and/or the dataset exists.

ICMSG026 Dataset not found

Explanation: The listed dataset is not found

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG028 &qfmemnam not found

Explanation: Install checker output member not found in install dataset.

User Response: Make sure the install checker output member and the install dataset names are spelled correctly and the member and dataset exist.

ICMSG029 &aplmemnm submitted

Explanation: &qfsubmsg has been submitted. The actual job name will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG030 Error opening database

Explanation: Error opening ISPF table TBATOTSK.

User Response: Make sure the TBATOTSK database table exists in your install PDS and ensure that it is not being accessed by another user.

ICMSG031 Error generating install members

Explanation: The install job generator encountered an error.

Page 143: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-7

User Response: Review the messages in the listed install log file, member INSTLOG, for details

ICMSG032 &qfmemnam not found

Explanation: Install job not found in install dataset. The actual job name will appear in the message on your screen.

User Response: Make sure the install job name and dataset name are spelled correctly and they exist.

ICMSG033 &qfmemnam submitted

Explanation: &qfsubmsg has been submitted. The actual job name will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG034 LE dataset not found

Explanation: Language environment dataset not found.

User Response: Make sure the language environment dataset name is spelled correctly and the dataset exists.

ICMSG035 Dataset not found

Explanation: System Proclib dataset not found.

User Response: Make sure the system proclib dataset name is spelled correctly and the dataset exists.

ICMSG036 Invalid DSORG

Explanation: The specified proclib must be partitioned.

User Response: Partition the specified proclib.

ICMSG037 Invalid member

Explanation: The member name is not valid.

User Response: Make sure the member name is spelled correctly and the member exists.

ICMSG038 Generate error

Explanation: QQFINSTN encountered an error creating $qfclstnm. The actual CLIST name will appear in the message on your screen.

User Response: Check for messages in &qfinstll member HISTORY. The actual member name will appear in the message on your screen.

ICMSG039 LMCOPY ERROR

Explanation: LMCOPY of member &qfclstnm from file &qfinstlb to file &qfuprclb failed. The actual member and file names will appear in the message on your screen.

User Response: Make sure the file and member names are spelled correctly and they exist. Retry LMCOPY.

ICMSG040 Clist created

Explanation: CLIST &qfclstnm created in &qfuprclb. The actual user proclib name will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG041 Installation processing error &qfsrtmsg

Explanation: Installation processing error &qflngmsg. The actual installation processing error will appear in the message on your screen.

User Response: Contact Hiperstation customer support.

Note: If return code (RC) ERRNO or ERRNOJR appears, see IBM Codes and Messages manual for details.

Page 144: Hiperstation Messages and Codes

4-8 Hiperstation Messages and Codes

ICMSG042 Invalid Dataset Name

Explanation: The listed dataset name is invalid.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG043 Environment not built

Explanation: The listed environment was not build.

User Response: You must complete Option 1, "Build Environment", before performing Installation and Customization tasks.

ICMSG044 Load not found

Explanation: Error allocating the listed loadlib.

User Response: Make sure the SQQFLOAD PDS has been allocated.

ICMSG045 Member created

Explanation: Global record startup proc created.

User Response: Informational message. No user action necessary.

ICMSG046 Elements generated

Explanation: HFS path created and subelements copied.

User Response: Informational message. No user action necessary.

ICMSG047 Member created

Explanation: Vtam script create proc created.

User Response: Informational message. No user action necessary.

ICMSG048 Command processed

Explanation: Generate processing complete. Dataset &qfgrrqfl &qffldfst, sysid association for &qfgrrsys &qfsyasst. The actual dataset names will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG049 Invalid Dataset Name

Explanation: Derived repository name is an invalid dataset name.

User Response: Make sure the dataset name is spelled correctly and the dataset exists.

ICMSG050 Invalid combination

Explanation: Number of prefix characters + suffix length value must be <= 8.

User Response: Re-enter the prefix and suffix characters.

ICMSG051 Invalid combination

Explanation: Number of terminals to generate is larger than the suffix length allows.

User Response: Ensure that the number of terminals to generate is not greater than the terminal suffix allows.

ICMSG052 &qfsampnm Generated

Explanation: Definitions generated into member &qfinstlb(&qfsampnm).

User Response: Informational message. No user action necessary.

ICMSG053 Macros moved

Explanation: Edit macros move to the listed proclib.

User Response: Informational message. No user action necessary.

ICMSG056 Assets Generated

Explanation: Playback and reporting assets have been created.

Page 145: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-9

User Response: After exiting this panel, see member &qfinstll(HISTORY) for details.

ICMSG057 Assets Generated

Explanation: Reporting assets have been created.

User Response: After exiting this panel, see member &qfinstll(HISTORY) for details.

ICMSG058 The Site Profile dataset already exists

Explanation: Rename the old site profile dataset or change the new site profile dataset name.

User Response: Informational message. No user action necessary.

ICMSG060 No entries found

Explanation: No custom signon entries exist.

User Response: Informational message. No user action necessary.

ICMSG061 No more entries

Explanation: No subsequent custom signon entries were found.

User Response: Informational message. No user action necessary.

ICMSG062 No more entries

Explanation: No previous custom signon entries were found.

User Response: Informational message. No user action necessary.

ICMSG063 Entry updated

Explanation: Entry for the listed screen ID was updated.

User Response: Informational message. No user action necessary.

ICMSG064 Entry added

Explanation: Entry for the listed screen ID was added.

User Response: Informational message. No user action necessary.

ICMSG065 Entry deleted

Explanation: Entry for the listed screen id was deleted.

User Response: Informational message. No user action necessary.

ICMSG066 Entry not found

Explanation: Entry for the listed screen id was deleted.

User Response: Informational message. No user action necessary.

ICMSG070 Installation processing error

Explanation: "&QFERRVAL" is not a valid value for parameter &QFERRPRM. The actual parameter value name will appear in the message on your screen.

User Response: Contact Compuware customer support.

ICMSG071 Invalid sort argument

Explanation: An invalid sort argument was used. Valid SORT arguments are Parameter and Location.

User Response: Reissue the sort using a valid argument.

ICMSG072 Parameter not found

Explanation: The listed parameter was not found.

User Response: Ensure that TBPRDPRM exists in the installation library.

ICMSG073 Location not found

Explanation: The listed parameter location was not found.

Page 146: Hiperstation Messages and Codes

4-10 Hiperstation Messages and Codes

User Response: Call help desk.

ICMSG074 Find failed

Explanation: Table scan for "&QFERRPRM" failed. The actual parameter name will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG075 Update failed

Explanation: Table update (TBMOD) for parameter "&QFERRPRM" failed. The actual parameter name will appear in the message on your screen.

User Response: Informational message. No user action necessary.

ICMSG076 Specify new SYSID

Explanation: Copy requires a new MVS SYSID.

User Response: Specify a new MVS SYSID.

ICMSG077 Assignment saved

Explanation: Association of sysid &grrsysid to &grrdsn saved.

User Response: Informational message. No user action necessary.

ICMSG078 Assignment(s) deleted

Explanation: Sysid association(s) have been deleted.

User Response: Informational message. No user action necessary.

ICMSG079 Delete failed

Explanation: Table delete (TBDELETE) for sysid "&QFERRPRM" failed. The actual parameter name will appear in the message on your screen.

User Response: Contact help desk.

ICMSG080 Fields VOLSER and GENUNIT are mutually exclusive

Explanation: VOLSER and GENUNIT cannot both be selected.

User Response: Leave one blank.

ICMSG081 Table update error

Explanation: Error updating ISPF table TBFLALOC, fileid &QFALFILE. The actual fileid will appear in the message on your screen.

User Response: Ensure the table exists in the installation library. If the problem persists, contact the help desk.

ICMSG082 Table Open error

Explanation: Error opening ISPF table TBFLALOC, return code &QFERRVAL.

User Response: Make sure the table name is spelled correctly and the table exists.

ICMSG085 Entry already exists

Explanation: A definition for the listed term already exists, copy not done.

User Response: Informational message. No user action necessary.

ICMSG086 Specify new DSN

Explanation: Update requires a new dataset name.

User Response: Enter a unique dataset name.

ICMSG087 Definition saved

Explanation: Terminal/applid definition for saved.

User Response: Informational message. No user action necessary.

Page 147: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-11

ICMSG088 Not allowed

Explanation: Copy not allowed for &vttype definition. The actual terminal definition will appear in the message on your screen.

User Response: Select COPY for DB2CS or LU2 types.

ICMSG089 SMS parameters and VOLSER are mutually exclusive. Leave one blank.

Explanation: SMS parameters and non-SMS parameters cannot be selected for the same product installation.

User Response: User must select to install the product utilizing SMS or non-SMS and deselect the other parameters.

ICMSG091 Invalid sort argument

Explanation: Valid SORT arguments are Status and Task.

User Response: Reissue the SORT using a valid argument.

ICMSG092 Member not found

Explanation: Tasklist member not found.

User Response: Informational message. No user action necessary.

ICMSG093 Tasklists members TSKCICS, TSKIMS, TSKMVS, TSKSECUR, TSKVTAM generated into file &qfinstlb.

Explanation: Install task list generated.

User Response: Informational message. No user action necessary.

ICMSG094 Error generating tasklist members. Review member &qfinstll(HISTORY) for details.

Explanation: Task list member generation error.

User Response: Informational message. No user action necessary.

ICMSG095 Generating usermod

Explanation: Generating usermod.

User Response: Informational message. No user action necessary.

ICMSG096 Error generating usermod "AUTOMOD". Review member &qfinstll(HISTORY) for details.

Explanation: Automod generation error.

User Response: Informational message. No user action necessary.

ICMSG097 Member submitted to RECEIVE and APPLY usermod "AUTOMOD"

Explanation: AUTOMOD job executed.

User Response: Informational message. No user action necessary.

ICMSG098 Error running install checker

Explanation: Install checker error occurred.

User Response: Review member &qfinstll(HISTORY) for details. The actual member name will appear in the message on your screen.

ICMSG099 Install checker output can be reviewed in &qfinstll(&qfmemnam)

Explanation: Install checker output in specified member.

User Response: Informational message. No user action necessary.

ICMSG100 Running install checker

Explanation: Product install check being conducted.

User Response: Informational message. No user action necessary.

Page 148: Hiperstation Messages and Codes

4-12 Hiperstation Messages and Codes

ICMSG103 Tasklists members TSKCICS, TSKIMS, TSKMVS, TSKSECUR, TSKVTAM generated into file &qfinstlb.

Explanation: Install task list generated.

User Response: Informational message. No user action necessary.

ICMSG104 Error generating tasklist members

Explanation: Error generating tasklist members.

User Response: Review member &qfinstll(HISTORY) for details. The actual member name will appear in the message on your screen.

ICMSG105 Generating “AUTOMOD”

Explanation: AUTOMOD being generated.

User Response: Informational message. No user action necessary.

ICMSG106 Error generating “AUTOMOD”

Explanation: Error generating usermod "AUTOMOD".

User Response: Review member &qfinstll(HISTORY) for details. The actual member name will appear in the message on your screen.

ICMSG107 Member &qfmemnam submitted to RECEIVE and APPLY usermod "AUTOMOD"

Explanation: Receive and apply member generated.

User Response: Informational message. No user action necessary.

ICMSG110 Dataset not found

Explanation: Old INSTALL dataset not found.

User Response: Make sure the dataset name is spelled correctly and dataset exists.

ICMSG111 Table &QFERRPRM not found

Explanation: Installation database table &qferrprm not found in dataset &qfoldins. The actual table and dataset names will appear in the message on your screen.

User Response: Make sure the database table name and dataset name are spelled correctly and they both exist.

ICMSG112 LIBDEF error

Explanation: Error allocating old install &qfoldins. The actual old installation file name will appear in the message on your screen.

User Response: Ensure that the old import dataset exists and is not in use.

ICMSG113 TBOPEN error

Explanation: Error allocating old install table &qferrprm. The actual table name will appear in the message on your screen.

User Response: Ensure that the &qferrprm member exists in the old installation library and is not in use.

ICMSG114 TBOPEN error

Explanation: Error allocating install table &qferrprm.

User Response: Ensure that the &qferrprm member exists in the old installation library and is not in use.

ICMSG115 Database imported

Explanation: Database imported from &qfoldins into &qfinstlb. The actual installation file names will appear in the message on your screen.

User Response: Informational message. No user action necessary.

Page 149: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-13

ICMSG116 Member not found

Explanation: Member &qfinstlb(APLYAUTO) not found. Unable to submit SMP/E RECEIVE and APPLY JCL. The actual member name will appear in the message on your screen.

User Response: Make sure the member name is spelled correctly and member exists. Resubmit SMP/E RECEIVE and APPLY JCL.

ICMSG120 Fields VOLSER and GENUNIT are mutually exclusive

Explanation: VOLSER and GENUNIT cannot both be selected.

User Response: Enter only one input source for the maintenance file.

ICMSG121 SMS Storage class and NONSMS Unit are mutually exclusive. Please select SMS NONSMS parameters for Dataset allocation.

Explanation: SMS parameters and non-SMS parameters cannot be selected for the same product installation.

System Action: None.

User Response: User must select to install the product utilizing SMS or non-SMS and deselect the other parameters.

ICMSG122 Work Unit cannot be input for NONSMS Dataset allocations. Please clear the Work unit field to proceed with the NONSMS allocation.

Explanation: SMS parameters and non-SMS parameters cannot be selected for the same product installation.

System Action: None.

User Response: User must select to install the product utilizing SMS or non-SMS and deselect the other parameters.

ICMSG123 Volume can only be utilized when the Unit parameter has been input. Please define the Unit for the Dataset allocation.

Explanation: Non-SMS Hiperstation for VTAM install allows the user to define a Unit (i.e., DASD) device where pooled resources can be utilized. Additionally, a Volume Serial number can be defined to specify a specific Tape or DASD location.

System Action: None.

User Response: Enter Unit parameter if Volume Serial Number needs to be specified.

ICMSG124 Product not found in the TBATOTSK please contact System Support

Explanation: One of the three products Hiperstation for VTAM, Hiperstation for WebSphere MQ or Hiperstation for Mainframe Servers required for Product installation was not selected.

System Action: None.

User Response: Contact Compuware Customer Support.

ICMSG125 NONSMS Volume Serial and SMS Management, Storage, and Data class are mutually exclusive parameters. Please select one.

Explanation: SMS parameters and non-SMS parameters cannot be selected for the same product installation.

System Action: None.

User Response: User must select to install the product utilizing SMS or non-SMS and deselect the other parameters.

ICMSG126 Member created. Archive Repository Registry Install proc &<Procedure name> created in <Install library>.

Explanation: Alerts the installer that the Archive Repository Registry procedure has been created successfully and where it is located.

System Action: Creates Archive Repository Registry automated task procedure.

User Response: None.

Page 150: Hiperstation Messages and Codes

4-14 Hiperstation Messages and Codes

ICMSG127 Custom Signon Security was selected but the Custom Signon Security Table is empty Either deselect Custom Signon Security on the “Select Products & Features to Install” panel or use the “Enable Custom Signon Security” panel to enter the appropriate Custom Signon Security entries.

Explanation: When selecting the Custom Signon Security, Signon definition entries must be added.

System Action: Terminates “Apply Parameter settings” function and utilizes Custom Signon Security entries to execute User security checking.

User Response: Use “Enable Custom Signon Security” panel to define Custom Signon Security entries, or deselect “Custom Signon Security” feature on “Select Products and Features to Install” screen.

ICMSG128 Invalid Server. The HTTP Server name <URL definition> must be < 40 characters.

Explanation: Defines Path to Archive Search Reports on the Mainframe.

System Action: None.

User Response: Utilize “Specify Other Dataset Information” (Option 1) to define the Archive Search Reports HTTP Sever name.

ICMSG129 No products have been selected to be installed. Please select “Install & Customize” (Option-3) to define desired Product base.

Explanation: No products were selected during the Installation process.

System Action: None.

User Response: Installer must use “Select Products & Features to Install” panel and select the desired Hiperstation for VTAM products to install.

ICMSG130 Please enter Product Cart VOLSER or the Maintenance file dataset name to execute the Receive and Apply Product Maintenance procedure.

Explanation: A Volume Serial number or Dataset name must be entered to define the location of the Product Maintenance file.

System Action: None.

User Response: Enter the correct Maintenance file Volume Serial number or Dataset name.

ICMSG131 Maintenance file dataset name is invalid. Please re-enter.

Explanation: Maintenance file dataset name is invalid (i.e., Not found).

System Action: None.

User Response: Enter correct Maintenance file dataset name.

ICMSG132 Product Cart Volser is invalid. Please reenter.

Explanation: Product Cart Volume Serial number is invalid (i.e., invalid character).

System Action: None.

User Response: Enter correct Product Cart Product Cart Volume Serial number.

ICMSG133 Invalid field input

Explanation: BYPASS Holdsystem indicator must be Y or N. Please re-enter.

ICMSG134 Invalid field input

Explanation: Apply Check indicator must be Y or N. Please re-enter.

ICMSG135 Dataset not found

Explanation: The entered Maintenance file dataset is not found.

ICMSG136 Storage and Management class must contain a 1 to 8 character value when utilizing SMS for an install

Explanation: Storage and Management class must contain a 1 to 8 character value when utilizing SMS for an install.

Page 151: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-15

ICMSG137 A valid Storage and Management class (SMS) or Unit (Non-SMS) must be entered to continue the install

Explanation: A valid Storage and Management class (SMS) or Unit (Non-SMS) must be entered to continue the install.

ICMSG140 Dataset not found

Explanation: Strobe Load Library &qfinddsn not found.

ICMSG141 Dataset not found

Explanation: Strobe History Library &qfinddsn not found.

ICMSG142 Dataset not found

Explanation: Strobe Path Library &qfinddsn not found.

ICMSG143 Dataset not found

Explanation: Strobe Log Library &qfinddsn not found.

MCSREPTMCSREPT-0200I Hiperstation Capture Segment Summary report processing started.

Explanation: Informational message indicating program execution.

MCSREPT-0201W Unable to obtain file information from file dsn.

Explanation: The report program was unable to obtain the file definition details for the indicated dataset (dsn).

System Action: Processing for the indicated dataset terminates. Processing continues with the next dataset.

User Response: Ensure that the dataset information is specified correctly on the DSN input parameter and run the job again.

MCSREPT-0202E Storage could not be allocated for ccc structure.

Explanation: The report program was unable to obtain storage for the specified internal control structure.

System Action: Processing terminates.

User Response: Increase the region size for the batch job and run the job again. If the problem persists, contact Compuware Customer Support.

MCSREPT-0203E Unable to open report file: DD CAPSUM Reason: ccc

Explanation: The report program was unable to open the reporting dataset specified on the CAPSUM DD statement due to the indicated reason. ccc is the system error message.

System Action: Processing terminates.

User Response: Resolve the indicated reason and run the job again.

MCSREPT-0204W Dataset dsn contains non-repository data, timeframe analysis stopped.

Explanation: The report program found invalid data in the indicated repository dataset (dsn).

System Action: Timeframe analysis for the indicated dataset terminates. Processing continues with the next repository dataset.

User Response: Ensure specified repositories contain only repository data captured by Global Recording.

MCSREPT-0205W Repository dataset dsn not found.

Explanation: The specified repository dataset (dsn) was not found.

Page 152: Hiperstation Messages and Codes

4-16 Hiperstation Messages and Codes

System Action: Timeframe analysis for the indicated dataset terminates. Processing continues with the next repository dataset.

User Response: Make sure the repository dataset name is specified correctly on the SYSIN parameters.

MCSREPT-0206E SYSIN file of input parameters could not be opened.

Explanation: The reporting program could not open the file specified on the SYSIN DD statement.

System Action: Processing terminates.

User Response: Ensure the dataset is correctly specified on the SYSIN DD, that the file is not currently in use, and that you have authority to access the dataset.

MCSREPT-0207I SYSIN ccc

Explanation: Informational messages indicating that the text ccc was read from file SYSIN.

MCSREPT-0208E SYSIN parameter ccc must be specified before first DSN.

Explanation: The indicated SYSIN parameter (ccc) was encountered after dataset processing.

System Action: The reporting program ignores the parameter.

User Response: Edit the SYSIN parameters. Place the indicated parameter before the first DSN parameter. Note: NORECALL and GMT must precede the first DSN parameter.

MCSREPT-0209E Cannot open any segment of repository dsn

Explanation: The reporting program was unable to open any of the datasets belonging to the indicated repository (dsn).

System Action: Processing continues with the next DSN specified in SYSIN.

User Response: Ensure that the repository name is specified correctly on the DSN, FIRST and LAST parameters in SYSIN, that the repository is not currently in use, and that you have the proper authority to access the specified repository datasets.

MCSREPT-0210I Datasets for repository dsn with wildcard(s) segments m through n not found.

Explanation: The reporting program was unable to locate the indicated repository segments. It resolves the wildcard characters in the dataset name with the FIRST and LAST values specified in the job input (SYSIN). m and n denote the range of values that did not resolve to existing datasets.

System Action: Processing continues. If the reporting program finds a qualifying dataset, it produces message MCSREPT_0211I which indicates the first dataset processed for reporting.

User Response: To avoid this message, ensure the values of the FIRST and LAST parameters are correct.

MCSREPT-0211I The first dataset processed is dsn

Explanation: This is an informational message that indicates the first dataset, within the specified range, that was found for report processing.

MCSREPT-0212W SYSIN parameter name is missing from input line n.

Explanation: The reporting program encountered a SYSIN control card without a parameter name on the indicated line.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN card and run the job again.

MCSREPT-0213E Unknown SYSIN parameter name parm located.

Explanation: The reporting program encountered a SYSIN control card with an invalid parameter name.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN card and run the job again.

Page 153: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-17

MCSREPT-0214E No value for SYSIN parameter parm detected on line n.

Explanation: The reporting program encountered a SYSIN parameter (parm), on line n, with no value.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN card and run the job again.

MCSREPT-0215E parm value ccc not a valid dataset name

Explanation: The indicated dataset name is invalid.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN card and run the job again.

MCSREPT-0216E The parm value ccc is greater than the n characters long

Explanation: Value ccc is too long for the indicated parameter (parm).

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Change the indicated parameter’s value to a value that is n or fewer characters and run the job again.

MSCREPT-0217E Invalid parm parameter integer value n

Explanation: A non-integer value (n) was supplied for the indicated parameter (parm).

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Change the value of the indicated parameter to an integer value and run the job again.

MCSREPT-0223E Parameter parm dataset dsn has a ccc character period

Explanation: The indicated dataset (dsn), which was specified on the indicated parameter (parm), is invalid because the first or final (ccc) character is a period.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN and run the job again.

MCSREPT-0224E Parameter parm dataset dsn has consecutive periods

Explanation: The indicated dataset (dsn), specified on the indicated parameter (parm) is invalid because it contains two or more consecutive periods.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN and run the job again.

MCSREPT-0225E Parameter parm dataset dsn is of invalid length

Explanation: The length of the indicated dataset name (dsn), specified on the indicated parameter (parm), is invalid because it exceeds 44 characters.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN and run the job again.

MCSREPT-0226E Parameter parm dataset dsn has invalid segment ccc

Explanation: The qualifier ccc of the indicated dataset (dsn), which was specified on the indicated parameter (parm), is invalid.

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN and run the job again.

MCSREPT-0227E Parameter parm integer n has a non-numeric character c

Explanation: The value of the indicated parameter (parm), which requires an integer value, is invalid because it contains the indicated non-numeric character (c).

System Action: Processing continues with the next control card specified in SYSIN.

User Response: Correct the SYSIN and run the job again.

Page 154: Hiperstation Messages and Codes

4-18 Hiperstation Messages and Codes

MCSREPT-0228E A Repository set must be specified

Explanation: The SYSIN contains a DSN parameter with no value.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the SYSIN and run the job again.

MCSREPT-0229E Fully expanded repository set specification dsn is > 44 characters

Explanation: The indicated repository dataset (dsn) containing wildcard characters is invalid because it will exceed 44 characters once the wildcards are resolved.

System Action: Processing continues with the next SYSIN control card.

User Response: Review the values supplied on the DSN parameter and the FIRST and LAST parameters. Correct the erroneous parameter and run the job again.

MCSREPT-0230E Only one asterisk is allowed in a REPOSITORY name dsn

Explanation: The indicated dataset (dsn) contains more than one asterisk wildcard.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the DSN parameter value and run the job again.

MCSREPT-0231E Asterisks and Question Marks cannot be mixed. dsn

Explanation: The indicated dataset (dsn) contains asterisks and question marks, which are mutually exclusive wildcards.

System Action: Processing continues with the next SYSIN control card.

User Response: Change the DSN parameter value to contain one or more question marks or a single asterisk wildcard.

MCSREPT-0232E Question Marks must be contiguous. dsn

Explanation: The indicated dataset (dsn) contains question marks separated by other characters. Question marks must be used consecutively.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the DSN parameter value and run the job again.

MCSREPT-0233E Too many consecutive question marks. dsn

Explanation: The indicated dataset (dsn) contains more than seven question marks. Seven is the maximum number of question mark wildcard characters allowed.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the DSN parameter in the SYSIN and run the job again.

MCSREPT-0234E FIRST value (n) must be less than the LAST value (m)

Explanation: The values specified on the FIRST parameter is greater than the value specified on the LAST parameter.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the FIRST and LAST parameter values and run the job again. Make sure that FIRST is less than LAST.

MCSREPT-0235E FIRST/LAST n/m too long to fit in wildcard area dsn

Explanation: The FIRST parameter value, LAST parameter value, or both parameter values contain more digits than the wildcard characters specified on the indicated dataset (dsn) allow.

System Action: Processing continues with the next SYSIN control card.

User Response: Correct the values of the FIRST and LAST parameters or change the wildcard specification on the indicated DSN and run the job again. - If the DSN contains question marks, the FIRST and LAST values should contain the same number or fewer digits than the number of question marks. - If the DSN contains an asterisk, then number of digits in the FIRST/LAST value plus the number of characters specified in the segment containing the asterisk must be eight or less.

Page 155: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-19

MQIOMQIO024E REPLAY=r OBJECT=i NO OPTIONS SELECTED ON MQOPEN.SCRIPT RECORD: rid

Explanation:

User Response: Ensure that the MQOO options have been specified for script record rid.

MQIO106W REPLAY=r OBJECT=obj_id MQGET FAILED. NO SUITABLE RECORD ON QUEUE: queue_name

Explanation: An MQ_GET was found in the script, but no record on queue_name satisfied the match options on the MQ_GET request, or no messages are in the queue.

User Response: Informational message. No user action necessary.

MQIO211E REPLAY=r, OBJECT=obj_id, MQOPEN FAILED. REASON=rc

Explanation: The MQOPEN function has failed.

User Response: Check reason code, correct error, and rerun.

MQIO214E REPLAY=r, OBJECT=obj_id, MQSET FAILED. REASON=rc

Explanation: The MQSET function has failed.

User Response: Check reason code, correct error, and rerun.

MQIO215E REPLAY=r, OBJECT=obj_id, MQ_PUT FAILED. ATTEMPTED TO PUT TO QUEUE: queue_name. EXP=script_rsn ACT=rsn.

Explanation: The MQPUT function has failed.

User Response: Check reason code, correct error, and rerun.

MQIO216E REPLAY=r, OBJECT=obj_id, MQ_PUT1 FAILED. ATTEMPTED TO PUT TO QUEUE: queue_name. EXP=script_rsn ACT=rsn.

Explanation: The MQPUT1 function has failed.

User Response: Check reason code, correct error, and rerun.

MQQMGRMQQMGR020E REPLAY=rid REQUEST_TYPE FAILED FOR QMANAGER: qmgr RETCODE: rc REASON: rsn

Explanation: The request_type for QMANAGER failed. The return code and reason are provided.

User Response: Correct associated errors and run the playback again. Refer to IBM’s MQSeries API Error Codes documentation for reason codes and corrective actions.

Code Description

r The number associated with script replay. Hiperstation for WebSphere MQ assigns this number serially, in the order in which the script replay starts.

i OBJECT_ID on the MQ_OPEN statement

rid The script record identifier for the MQ_OPEN statement. In the example below, 123 is the rid:

<MQ_OPEN OBJECT_ID - 3,...>123

Page 156: Hiperstation Messages and Codes

4-20 Hiperstation Messages and Codes

MQROLEMQROLE204E INVALID QUEUE NAME FOUND: queue_name

Explanation: The PLAY_TO or PLAY_AS control statement has an invalid queue specification.

User Response: Correct the queue_name and re-run the playback.

MQROLE207E QUEUE NAME IS NOT PROPERLY ENCLOSED IN QUOTES OR PARENTHESIS QUEUE: queue_name

Explanation: The PLAY_TO or PLAY_AS control statement has an invalid queue specification and/or unbalanced parenthesis.

User Response: Correct the error and re-run the playback.

MQSSEVNTMQSSEVNT041E QMGR_NAME DEFINED FOR MQ_CONNECT STATEMENT

User Response: Include a QUEUE_MANAGER control card on the SCRIPT, MQGROUP or CONTROL statement, or locate the MQ_CONNECT statement that is in error and add a QMGR_NAME parameter.

MQSSEVNT094I REPLAY=r OBJECT=y SCRIPT RECORD=rid SKIPPED. REASON=sssss

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

MQSSEVNT201E REPLAY=r SCRIPT RECORD: rid BOTH OBJECT_ID AND CONNECTION_ID ARE REQUIRED.

Explanation: The MQ_OPEN requested via script record rid requires both a CONNECTION_ID and OBJECT_ID.

User Response: Include both a CONNECTION_ID and OBJECT_ID.

MQSSEVNT202E REPLAY: r INVALID OR MISSING QMGR NAME ON SCRIPT RECORD: rid

Explanation: The MQ_CONNECT statement on script record rid has a missing or invalid QMGR_NAME parameter.

User Response: Correct the MQ_CONNECT statement and re-run the playback.

MQSSEVNT203E REPLAY: r MQ_CONNECT STATEMENT: rid HAS INVALID OR MISSING CONNECTION_ID TAG

Explanation: Verify that a valid CONNECTION_ID is present within the MQ_CONNECT tag.

User Response: Correct the MQ_CONNECT statement rid and re-run the playback.

MQSSEVNT205E REPLAY: r UNABLE TO PROCESS MQ_CONNECT. SCRIPT RECORD=rid CONNECTION_ID=qmgr_id QMGR=qmgr

Explanation: The MQ_CONNECT statement failed for script record rid.

User Response: Review prior error messages for details.

MQSSEVNT206E REPLAY: r MQ_CONNECT request failed. SCRIPT RECORD=rid CONNECTION_ID=qmgr_id QMGR=qmgr

Explanation: The MQ_CONNECT statement failed for script record rid.

User Response: Review prior error messages for details.

Page 157: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-21

QFINSQFINS271E Error generating manual task list TSKSECUR. Write member rc = 1

Explanation: An error occurred while generating manual task list TSKSECUR.

System Action: Manual Task Generation continues.

User Response: Review the generated manual tasks for clarity. If the instructions are unclear, contact Compuware Customer Support.

QQFDCIQQFDCIIP-0001I HIPERSTATION GLOBAL RECORDING BATCH INTERFACE

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0002E ERROR DEFINING XTRMGRDS

Explanation: An internal VDEFINE failed.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0003E ERROR DEFINING XTRMPTFL

Explanation: An internal VDEFINE failed.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0004E ERROR SETTING CONTROL TO NON-DISPLAY

Explanation: Loading variables internally failed.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0005E ERROR SETTING XTRMGRDS

Explanation: Loading variables internally failed.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0006E ERROR SETTING XTRMPTFL

Explanation: Loading variables internally failed.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0007I HIPERSTATION GLOBAL RECORDING BATCH INTERFACE RETURN CODE= xxxxxxxx

User Response: Global Recording status information. No action necessary. For non-zero return codes, contact Hiperstation technical support.

QQFDCIIP-0008E THE GLOBAL RECORDING SUBSYSTEM IS NOT ACTIVE

Explanation: The Global Record started task is not running on the system.

User Response: Execute the started task on the system.

QQFDCIIP-0009I THE GLOBAL RECORDING SUBSYSTEM IS RUNNING VERSION xxxxxxxx

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0010E SPACES NOT ALLOWED IN DATA

Explanation: Parsing user data found spaces in the submit job.

User Response: Remove the offending spaces and resubmit.

QQFDCIIP-0011E DATE xxxxxxxx FOR TAG <yyyyyyyy> - INVALID SYNTAX

Explanation: The date value for the above xml tag is invalid.

User Response: Enter a valid date format and resubmit.

Page 158: Hiperstation Messages and Codes

4-22 Hiperstation Messages and Codes

QQFDCIIP-0012E INVALID MONTH

Explanation: The month value in the xml is not valid.

User Response: Enter a valid month value and resubmit.

QQFDCIIP-0013E INVALID DAY

Explanation: The day value in the xml is not valid.

User Response: Enter a valid day value and resubmit.

QQFDCIIP-0014E INVALID YEAR

Explanation: The year value in the xml is not valid.

User Response: Enter a valid year value and resubmit.

QQFDCIIP-0015E DATE SPECIFIED NOT LEAP YEAR

Explanation: The date value in the xml contains leap year values for a non-leap year.

User Response: Enter a valid date value and resubmit.

QQFDCIIP-0016E FORMAT FOR DATE IS DD/MM/YYYY

Explanation: The date format in the xml is not valid.

User Response: Enter the date using the above format and resubmit.

QQFDCIIP-0017E FORMAT FOR TIME IS HH:MM:SS

Explanation: The time format in the xml is not valid.

User Response: Enter the time using the above format and resubmit.

QQFDCIIP-0018E INVALID TAG FOR THIS PROTOCOL

Explanation: The xml contains a tag that is not valid.

User Response: Remove invalid tag and resubmit.

QQFDCIIP-0019E DATA CAN CONTAIN NO SPACES

Explanation: Parsing user data found spaces in the submit job.

User Response: Remove the offending spaces and resubmit.

QQFDCIIP-0020E INPUT NOT NUMERIC

Explanation: Parsing user input found non-numeric data in the submit job.

User Response: Enter numeric data and resubmit.

QQFDCIIP-0021E TAG OUT OF SEQUENCE

Explanation: Parsing user data found xml tags in the wrong order in the submit job.

User Response: Reorder the xml tags, making sure they match up and resubmit.

QQFDCIIP-0022E INPUT REQUIRED

Explanation: Parsing user data found missing data in the submit job.

User Response: Enter missing data and resubmit.

QQFDCIIP-0023E INPUT INVALID FOR THIS TAG

Explanation: Parsing user data found invalid data in the submit job.

User Response: Enter valid data and resubmit.

QQFDCIIP-0024E AMOUNT MUST BE "ALL" OR NUMERIC

Explanation: Parsing user data found invalid data in the submit job.

User Response: Enter a numeric value or the word ALL and resubmit.

Page 159: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-23

QQFDCIIP-0025E REQUEST IS DISABLED

Explanation: The action cannot be performed on a disabled request.

User Response: Enable the request first and resubmit.

QQFDCIIP-0026E REQUEST IS NOT ACTIVE

Explanation: The action cannot be performed on an inactive request.

User Response: Activate the request first and resubmit.

QQFDCIIP-0027E DATA TOO SHORT

Explanation: Parsing user data found data that is too short in the submit job.

User Response: Enter a proper value and resubmit.

QQFDCIIP-0028E DATA TOO LONG

Explanation: Parsing user data found data that is too long in the submit job.

User Response: Enter a proper value and resubmit.

QQFDCIIP-0029E TAG <I-AM-SB1> INVALID FOR SELECTED PROTOCOL

Explanation: Parsing user data found an xml tag which is invalid in the submit job.

User Response: Remove the invalid xml tag and resubmit.

QQFDCIIP-0030E END TAG </xxxxxxxx> DOES NOT MATCH START TAG <yyyyyyyy>

Explanation: Parsing user data found invalid matching xml tags in the submit job.

User Response: Ensure xml tags are matching and resubmit.

QQFDCIIP-0031E NO START TAG FOUND FOR DATA -> xxxxxxxx

Explanation: Parsing user xml found data without a start tag in the submit job.

User Response: Ensure xml tags are present and matching and resubmit.

QQFDCIIP-0032E NO CORRESPONDING END TAG FOUND FOR START TAG <xxxxxxxx>

Explanation: Parsing user data found invalid matching xml tags in the submit job.

User Response: Ensure xml tags are matching and resubmit.

QQFDCIIP-0033E INVALID XML FORMAT FOR COMMENT-> xxxxxxxx

Explanation: Parsing user data found invalid xml comment data in the submit job.

User Response: Ensure xml is properly formatted and resubmit.

QQFDCIIP-0034E INVALID TOKEN FOUND -> xxxxxxxx

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure data is valid and resubmit.

QQFDCIIP-0035E NO START TAG FOUND FOR END TAG xxxxxxxx

Explanation: Parsing user data found invalid matching xml tags in the submit job.

User Response: Ensure xml tags are matching and resubmit.

QQFDCIIP-0036E THE START DATE/TIME MUST BE LESS THAN THE STOP DATE/TIME

Explanation: Parsing user data found invalid date/time values in the submit job.

User Response: Ensure start time/date is earlier than the end time/date and resubmit.

QQFDCIIP-0037E DATA 'xxxxxxxx' FOR TAG <yyyyyyyy> - LENGTH ERROR

Explanation: Parsing user data found an invalid data length in the submit job.

User Response: Ensure the data is the proper length and resubmit.

Page 160: Hiperstation Messages and Codes

4-24 Hiperstation Messages and Codes

QQFDCIIP-0038E DATA 'xxxxxxxx' FOR TAG <yyyyyyyy> - INVALID

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure the data is valid and resubmit.

QQFDCIIP-0039E DATA 'xxxxxxxx' FOR TAG <yyyyyyyy> - DUPLICATE TAG FOUND

Explanation: Parsing user data found a duplicate xml tag in the submit job.

User Response: Remove the duplicate xml tag and resubmit.

QQFDCIIP-0040E TIME NOT VALID

Explanation: Parsing user data found an invalid time value in the submit job.

User Response: Ensure the time value is valid and resubmit.

QQFDCIIP-0041E BOTH START DATE AND END DATE MUST BE SPECIFIED

Explanation: Parsing user data found a missing date value in the submit job.

User Response: Ensure there are values for both start and end dates and resubmit.

QQFDCIIP-0042E NO DATE SPECIFIED

Explanation: Parsing user data found a missing date value in the submit job.

User Response: Specify a valid date and resubmit.

QQFDCIIP-0043E NO RECORD CRITERIA SPECIFIED

Explanation: Parsing user data found missing criteria in the submit job.

User Response: Ensure there are record criteria present and resubmit.

QQFDCIIP-0044E ADDRESS MUST BE 4 SEGMENTS

Explanation: Parsing user data found an invalid IP address in the submit job.

User Response: Ensure the IP address is valid and resubmit.

QQFDCIIP-0045E TOO MANY POSITIONS BETWEEN PERIODS

Explanation: Parsing user data found an invalid IP address in the submit job.

User Response: Ensure the IP address is valid and resubmit.

QQFDCIIP-0046E INVALID SYNTAX

Explanation: Parsing user data found some invalid data in the submit job.

User Response: Ensure the data is valid and resubmit.

QQFDCIIP-0047E ADDRESS SEGMENT VALUE HIGHER THAN 255

Explanation: Parsing user data found an invalid IP address in the submit job.

User Response: Ensure the IP address is valid and resubmit.

QQFDCIIP-0048E SEGMENT NOT NUMERIC

Explanation: Parsing user data found an invalid IP address in the submit job.

User Response: Ensure the IP address is valid and resubmit.

QQFDCIIP-0049E SEGMENTS MUST BE WILDCARD OR NUMERIC

Explanation: Parsing user data found an invalid IP address in the submit job.

User Response: Ensure the IP address is valid and resubmit.

QQFDCIIP-0050E UNABLE TO ALLOCATE REQUEST FILE xxxxxxxx RC=yyyy

Explanation: The request file could not be allocated.

User Response: Ensure you have access to create the filename specified.

Page 161: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-25

QQFDCIIP-0051E INPUT SHOULD BE Y OR N

Explanation: Parsing user data found invalid input in the submit job.

User Response: Ensure the input is Y or N and resubmit.

QQFDCIIP-0052E INPUT NOT NUMERIC

Explanation: Parsing user data found non-numeric input in the submit job.

User Response: Ensure the input is numeric and resubmit.

QQFDCIIP-0053E INVALID FILTER TYPE

Explanation: Parsing user data found an invalid filter type in the submit job.

User Response: Ensure the filter type is valid and resubmit.

QQFDCIIP-0054E INVALID DATASET NAME

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0055E PORT HIGHER THAN 64K

Explanation: Parsing user data found an invalid port number in the submit job.

User Response: Ensure the port number is less than 64000 and resubmit.

QQFDCIIP-0056E XML TAG NOT CLOSED FOR xxxxxxxx

Explanation: Parsing user data found non-matching xml tags in the submit job.

User Response: Ensure the xml tags are closed and resubmit.

QQFDCIIP-0057E SPECIFIED MANAGER LIST NOT FOUND

Explanation: The submit job contains a manager list that does not exist.

User Response: Ensure the manager list exists and resubmit.

QQFDCIIP-0058E YOU MUST SUPPLY FIRST AND LAST NUMBERS WHEN YOU SUPPLY WILDCARDS

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure that first and last numbers are specified and resubmit.

QQFDCIIP-0059E FIRST OR LAST NUMBER IS TOO LARGE FOR INDICATED SPACE IN DATASET NAME

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure the first/last numbers are valid and resubmit.

QQFDCIIP-0060E ERROR READING REQUEST RECORD

Explanation: The request record could not be read into the program.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0061E INVALID FUNCTION

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure the function name is valid and resubmit.

QQFDCIIP-0062I SCRIPT CREATE COMPLETED WITHOUT ERRORS

User Response: Script Create status information. No action necessary.

QQFDCIIP-0063E SCRIPT CREATE COMPLETED WITH ERRORS

Explanation: Errors were encountered during the script creation process.

User Response: Check the job log for further details.

Page 162: Hiperstation Messages and Codes

4-26 Hiperstation Messages and Codes

QQFDCIIP-0064E A DATASET NAME MUST BE A-Z, 0-9, OR NATIONAL CHARACTERS

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0065E ONLY ONE * IS ALLOWED IN A DATASET NAME

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset contains at most one * and resubmit.

QQFDCIIP-0066E EITHER * OR ? MAY APPEAR, BUT NOT BOTH

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0067E A NODE IN A DATASET NAME MUST BE FROM 1 TO 8 CHARACTERS

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0068E THE 1ST CHARACTER IN A DSN SEGMENT MUST BE A-Z OR @#$

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0069E NO OTHER CHARACTERS ALLOWED BETWEEN ? CHARACTERS

Explanation: Parsing user data found an invalid dataset name in the submit job.

User Response: Ensure the dataset name is valid and resubmit.

QQFDCIIP-0070I REQUEST SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0071I REQUEST DISABLED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0072I REQUEST ADDED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0073I STOP REQUEST SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0074I CANCEL REQUEST SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0075I FORCE REQUEST SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0076I RESTART SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0077I SWITCH SCHEDULED

User Response: Global Recording status information. No action necessary.

QQFDCIIP-0078E REQUEST FAILED

Explanation: The Global Recording request failed to execute.

User Response: Check the job log for further details.

QQFDCIIP-0079E THE FIRST NUMBER MUST BE LESS THAN THE LAST NUMBER

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure the value of the first field is less than the value for last and resubmit.

Page 163: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-27

QQFDCIIP-0084E INVALID KEYWORD

Explanation: Parsing user data found an invalid keyword in the submit job.

User Response: Check the job log for further details.

QQFDCIIP-0085E SUPPLIED VALUE OUT OF RANGE

Explanation: Parsing user data found invalid data in the submit job.

User Response: Ensure the value is within the valid range and resubmit.

QQFDCIIP-0086E REQUEST RECORD ALREADY EXISTS

Explanation: The supplied record already exists in the request file.

User Response: Use the existing record, or cancel it and resubmit a new one.

QQFDCIIP-0087E PARM FIELD KEYWORD INVALID

Explanation: Parsing user data found an invalid keyword in the submit job.

User Response: Ensure the parm field keyword is valid and resubmit.

QQFDCIIP-0092E THE FIRST CHARACTER MUST BE ALPHABETIC (A-Z, $, @, OR #)

Explanation: Parsing user data found an invalid character in the submit job.

User Response: Ensure the name uses valid characters and resubmit.

QQFDCIIP-0093E REQUEST RECORD NOT FOUND, REQUEST FAILED

Explanation: The record could not be found in the request file.

User Response: Submit a new request job.

QQFDCIIP-0094E DATASET 'xxxxxxxx' LRECL/BLOCKSIZE MISMATCH

Explanation: The specified dataset has an invalid LRECL/BLOCKSIZE defined.

User Response: Ensure the dataset stats match and resubmit.

QQFDCIIP-0095E MANAGER LIST MUTUALLY EXCLUSIVE WITH <TERMINAL>, <APPLICATION>, AND <USER_ID>

Explanation: A Manager List is used in place of Terminal/Application/Userid.

User Response: Remove either the List or the Terminal/Application/Userid and resubmit.

QQFDCIIP-0096E SYSTEM SECURITY INTERFACE (RACF OR OTHER) DECIDED THIS FUNCTION IS RESTRICTED

Explanation: Your system security package restricts you from using this function.

User Response: Contact your system security administrator.

QQFDCIIP-0097E FATAL INTERNAL ERROR IN xxxxxxxx.

Explanation: An internal error has occurred.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0098E UNABLE TO ACQUIRE LICENSE INFORMATION

Explanation: Hiperstation was unable to find a valid license.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0099E I/O ERROR

Explanation: A system error has occurred.

User Response: Contact Hiperstation technical support.

QQFDCIIP-0100E CONVERSATION LOG REQUESTED WITH NO DSN SPECIFIED

Explanation: No dataset name was specified for the conversation log.

User Response: Specify a dataset name and resubmit.

Page 164: Hiperstation Messages and Codes

4-28 Hiperstation Messages and Codes

QQFDCIIP-0101E SCRIPT REQUESTED WITH NO DSN SPECIFIED

Explanation: No dataset name was specified for the script dataset.

User Response: Specify a dataset name and resubmit.

QQFDCIIP-0102E COMBINED DETAIL REQUESTED WITH NO DSN SPECIFIED

Explanation: No dataset name was specified for the combined detail dataset.

User Response: Specify a dataset name and resubmit.

QQFDCIIP-0103E INBOUND DETAIL REQUESTED WITH NO DSN SPECIFIED

Explanation: No dataset name was specified for the inbound detail dataset.

User Response: Specify a dataset name and resubmit.

QQFDCIIP-0104E OUTBOUND DETAIL REQUESTED WITH NO DSN SPECIFIED

Explanation: No dataset name was specified for the outbound detail dataset.

User Response: Specify a dataset name and resubmit.

QQFDCIIP-0105E NO INBOUND DDNAME SPECIFIED

Explanation: The submit job contains no inbound ddname.

User Response: Specify a ddname and resubmit.

QQFDCIIP-0106E NO OUTBOUND DDNAME SPECIFIED

Explanation: The submit job contains no outbound ddname.

User Response: Specify a ddname and resubmit.

QQFDCIIP-0107E NO MEMBER PREFIX/SUFFIX SPECIFIED FOR SCRIPT DATASET

Explanation: The script dataset has no member prefix or suffix specified.

User Response: Specify a prefix/suffix and resubmit.

QQFDCIIP-0108E NO MEMBER PREFIX/SUFFIX SPECIFIED FOR INBOUND DETAIL DATASET

Explanation: The inbound detail dataset has no member prefix or suffix specified.

User Response: Specify a prefix/suffix and resubmit.

QQFDCIIP-0109E NO MEMBER PREFIX/SUFFIX SPECIFIED FOR OUTBOUND DETAIL DATASET

Explanation: The outbound detail dataset has no member prefix or suffix specified.

User Response: Specify a prefix/suffix and resubmit.

QQFDCIIP-0110E NO MEMBER PREFIX/SUFFIX SPECIFIED FOR COMBINED DETAIL DATASET

Explanation: The combined detail dataset has no member prefix or suffix specified.

User Response: Specify a prefix/suffix and resubmit.

QQFDCIIP-0111E NO MEMBER PREFIX/SUFFIX SPECIFIED FOR CONVERSATION LOG

Explanation: The conversation log dataset has no member prefix or suffix specified.

User Response: Specify a prefix/suffix and resubmit.

QQFDCIIP-0112E SCRIPTS REQUESTED BUT NO SCRIPT CRITERIA SPECIFIED

Explanation: The submit job contains no script criteria.

User Response: Specify some script criteria or do not request a script and resubmit.

QQFDCIIP-0113E NO COMBINED DDNAME SPECIFIED

Explanation: The submit job contains no combined ddname.

User Response: Specify a combined ddname and resubmit.

Page 165: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-29

QQFDCIIP-0114E VALID END TIME REQUIRED WHEN FORCE REQUEST AT END TIME SPECIFIED

Explanation: The submit job contains an invalid end time.

User Response: Specify a valid end time or do not force at end time and resubmit.

QQFDCIIP-0115E USE MESSAGE FILTERS SPECIFIED WITH NO REXX DATASET

Explanation: The submit job contains no rexx dataset name.

User Response: Specify a rexx dataset name or do not use message filters and resubmit.

QQFDCIIP-0116E NO WILDCARD SPECIFIED WITH RE-USE REPOSITORIES

Explanation: The re-use repository option requires a wildcard for the dataset.

User Response: Specify a wildcard for the repository dataset and resubmit.

QQFDCIIP-0117E TERMINAL/APPLICATION/USERID FIELDS ARE MUTUALLY EXCLUSIVE WITH GLOBAL RECORD MANAGER LISTS

Explanation: A Manager List is used in place of Terminal/Application/Userid.

User Response: Remove either the List or the Terminal/Application/Userid and resubmit.

QQFDCIIP-0118E ONLY ONE TOP LEVEL ELEMENT IS ALLOWED IN AN XML DOCUMENT, TAG <xxxxxxxx> INVALID

Explanation: The submit job contains more than one top level xml tag.

User Response: Remove the invalid xml tag and resubmit.

QQFDCIIP-0119E TERMINAL, USERID, OR GLOBAL RECORD MANAGER LIST ARE REQUIRED.

Explanation: Either a Manager List or Terminal/Userid are required in the submit job.

User Response: Specify either a List or the Terminal/Userid and resubmit.

QQFDCIIP-0120E ERROR ALLOCATING 'xxxxxxxx'

Explanation: xxxxxxxx could not be allocated on the system.

User Response: Ensure system security permissions allow allocations using specified name.

QQFDCIIP-0121E NO MATCHING REQUEST RECORD FOUND

Explanation: A matching request record could not be found in the request file.

User Response: Create a new request to use.

QQFDCIIP-0122E ROW/COLUMN FORMAT ONLY VALID WITH FORMATTED SCRIPTS

Explanation: row/column format cannot be used with unformatted scripts.

User Response: Use formatted scripts or do not use row/column format and resubmit.

QQFDCIIP-0123E TAG <xxxxxxxx> - WHITESPACE IS NOT ALLOWED IN THIS LOCATION

Explanation: Spaces cannot exist in this xml tag value.

User Response: Remove white space from value and resubmit.

QQFDCIIP-0124E EITHER NO CORRESPONDING END TAG, OR INVALID DATA FOUND FOR START TAG <xxxxxxxx>

Explanation: The submit job contains invalid xml.

User Response: Ensure that xxxxxxxx has an end tag and the values are valid and resubmit.

QQFDCIIP-0125E SCRIPTS COMMAND ONLY AVAILABLE FOR 3270/APPC

Explanation: The scripts command cannot be used with the specified protocol.

User Response: Remove the scripts command or use 3270/APPC protocols and resubmit.

QQFDCIIP-0126E CAPTURE FILE DATASET REQUIRED

Explanation: No capture file dataset was specified in the submit job.

Page 166: Hiperstation Messages and Codes

4-30 Hiperstation Messages and Codes

User Response: Specify a capture file dataset and resubmit.

QQFDCIIP-0127E REQUEST ID REQUIRED

Explanation: No request id was specified in the submit job.

User Response: Specify a request id dataset and resubmit.

QQFDCIIP-0128E THE REQUEST MUST BE ACTIVE IN ORDER TO SWITCH SEGMENTS

Explanation: Inactive requests cannot switch segments.

User Response: Activate the request and resubmit.

QQFDCIIP-0129E THE RECORDING TASK MUST BE ACTIVE IN ORDER TO SWITCH SEGMENTS

Explanation: The global recording task is not running.

User Response: Execute the started task job and resubmit.

QQFDCIIP-0130E SWITCH REQUEST IS ONLY AVAILABLE FOR SEGMENTED REPOSITORIES

Explanation: Switch cannot be used with a single repository.

User Response: Use segmented repositories and resubmit.

QQFDCIIP-0131E EMPTY CONTROL CARD OR NO SYSIN DD SPECIFIED

Explanation: No control card or sysin dd was specified in the submit job.

User Response: Specify a control card or sysin dd and resubmit.

QQFDCIIP-0132E UNABLE TO OPEN REQUEST FILE xxxxxxxx RC=yyyy

Explanation: The request file could not be accessed to be read.

User Response: Check system security permissions or contact Hiperstation technical support.

QQFDCIIP-0133E START DATE REQUIRED WITH START TIME

Explanation: Start time cannot be used without start date in the submit job.

User Response: Specify a start date and resubmit.

QQFDCIIP-0134E END DATE REQUIRED WITH END TIME

Explanation: End time cannot be used without end date in the submit job.

User Response: Specify an end date and resubmit.

QQFDCIIP-0135E 1ST FILTER MUST BE A LIST IF 2ND FILTER SPECIFIED

Explanation: Second filter cannot be used unless first filter is a list in the submit job.

User Response: Specify a list for the first filter and resubmit.

QQFDCIIP-0136E NON-UNIQUE ARCHIVE REQUEST SPECIFIED

Explanation: The archive request already exists in the request file.

User Response: Specify a unique request and resubmit.

QQFDCIIP-0137E INVALID DESCRIPTION - CANNOT CONTAIN ¦{}[]`~¢

Explanation: The description contains invalid characters in the submit job.

User Response: Specify a valid description and resubmit.

QQFDCIIP-0138E INVALID DATASET SPECIFICATION FOR ARCHIVE REQUEST SPECIFIED

Explanation: The archive request in the submit job contains invalid dataset parameters.

User Response: Specify valid dataset parameters and resubmit.

Page 167: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-31

QQFHCIQQFHCI-0001I Initializing the Hiperstation Server which is communicating with HCI subsystem <system-id>

Explanation: The Hiperstation Server was started by the HCI system designated by <system-id>.

User Response: Informational message. No user action necessary.

QQFHCI-0002E HCI initialization failed, RC=<return-code>

Explanation: The HCI interface failed to initialize. <return-code> is either an 8, which reflects a failure to obtain heap storage, or <return-code> reflects the return code from a previous error message.

User Response: For RC=8, ensure that the Hiperstation Server task has an adequate REGION size associated with it.

QQFHCI-0022I Terminating the Hiperstation Server

Explanation: Indicates that the Hiperstation Server job has completed.

User Response: Informational message. No user action necessary.

QQFHCIINQQFHCIIN-0003E Could not get <client | server> codepage (<function>)

Explanation: The code page for the client or server could not be determined. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: For server code pages, check the &CODEPAGE parameter in panel library member, ETRMGPAR. For client code pages, check the client code page value in the Hiperstation default and user's profiles.

QQFHCIIN-0004E Could not open converter from <from-codepage> to <to-codepage> (<function>)

Explanation: The attempt to open a converter with IBM's iconv utility failed using the <from-codepage> and <to-codepage>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check the IBM documentation for the iconv utility to ensure that the conversion between the specified <from-codepage> and <to-codepage> code pages is supported. If not, change either the &CODEPAGE parameter in panel library member, ETRMGPAR, for the server code page or the client code page value in the Hiperstation default and user's profile.

QQFHCIIN-0005E Error in converting characters: <errno> - <errno-text> (<function>)

Explanation: IBM's iconv utility encountered an error when converting data. <errno> is the POSIX error number and <errno-text> is the text associated with <errno>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the &CODEPAGE parameter in the panel library ETRMGPAR for the server code page and the client code page used in Hiperstation profiling are valid for the environment. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHCIIN-0006I <Client | Server> Code Page = <codepage>

Explanation: Specifies the codepage that is being used for the client or server. This message is generated because of a QQFHCIIN-0005E message.

User Response: Informational message. No user action necessary.

Page 168: Hiperstation Messages and Codes

4-32 Hiperstation Messages and Codes

QQFHCIIN-0007I <number> bytes converted

Explanation: Indicates the number of bytes successfully converted by IBM's iconv utility. This message is generated because of a QQFHCIIN-0005E message.

User Response: Informational message. No user action necessary.

QQFHCIIN-0008I <number> bytes remaining to be converted from source

Explanation: Indicates the remaining number of bytes that were not converted. This message is generated because of a QQFHCIIN-0005E message.

User Response: Informational message. No user action necessary.

QQFHCIIN-0009E Unable to allocate <control-block> (<function>)

Explanation: An attempt to allocate storage for internal control block <control-block> failed. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the Hiperstation Server task has an adequate REGION size associated with it.

QQFHCIIN-0010E Call <HCI-call> failed, RC=<return-code> (<function>)

Explanation: <HCI-call> failed with <return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check message QQFHCIIN-0011I immediately following this message for further information. Contact Hiperstation Customer Support.

QQFHCIIN-0011I Detailed info: <error-text> (<type-rc>=<return-code> Function=<function> Call=<call>)

Explanation: <error-text> displays detailed text regarding an HCI error. <return-code> indicates the internal HCI return code. <type-rc> indicates the what type of error the <return-code> is. <function> indicates the function where the error occurred. <call> indicates the name of the internal HCI call where the error occurred.

User Response: Write the return code and contact Hiperstation Customer Support.

QQFHCIIN-0012I Initialization completed, RC=<return-code> (<function>)

Explanation: Indicates the HCI initialization routine has completed. <return-code> indicates whether the HCI initialization was successful. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check previous messages for errors if RC is not 0.

QQFHCIIN-0013I Attempting to logon as <userid> (<function>)

Explanation: Indicates that the client is attempting to logon to the HCI as <userid>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHCIIN-0014I Attempting to change the password for <userid> (<function>)

Explanation: Indicates that the client is attempting to change the password for <userid>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHCIIN-0015I Logon of <userid> was successful (<function>)

Explanation: Indicates that the client successfully logged in as <userid>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

Page 169: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-33

QQFHCIIN-0016I Termination completed, RC=%i (<function>)

Explanation: The Hiperstation Server successfully terminated from the HCI task. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check for previous error messages if RC is not 0.

QQFHCIIN-0017E Invalid control data: <reason> (<function>)

Explanation: The header data passed from the client application to the Hiperstation Server job contains invalid data. <reason> indicates which header field is invalid. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job. Also, ensure that the client and server code pages are correct. The server code page is specified by the &CODEPAGE parameter in panel library member ETRMGPAR. The client code page is specified in the Hiperstation default and user's profile.

QQFHCIIN-0018E Conversation error, RC=<return-code> (<function>)

Explanation: An error occurred during the conversation with the client application and the Hiperstation Server job. <return-code> is an internal HCI value. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHCIIN-0019I Receive message completed, RC=<return-code> (<function>)

Explanation: Indicates the success or failure of the function receiving data from the client application. <return-code> reflects return code from HCI functions. This message is only produced when running under diagnostic mode. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHCIIN-0020E Bad control data received, RC=<return-code> (<function>)

Explanation: Validation of header data passed from the application failed. This message should be preceded by a QQFHCIIN-0017E message. <return-code> reflects which field of the header failed. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: See “User Response” for QQFHCIIN-0017E.

QQFHCIIN-0021I Send message completed, RC=<return-code> (<function>)

Explanation: Indicates the success or failure of the function sending data to the client application. <return-code> reflects return code from HCI functions. This message is only produced when running under diagnostic mode. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHDATAQQFHDATA-0006W Unknown field <field-name> found

Explanation: A field called <field-name> was found on the Vantage hdata file's Field description record that is not recognized by the conversion program. This can happen if the version of the hdata file is not supported by Hiperstation's Vantage conversion program.

User Response: Ensure the conversion ran without error.

QQFHDATA-0007E Field number <field-number> is undefined

Explanation: A record was read that contains more fields than the Vantage hdata file's Field description record.

User Response: Contact Vantage Agentless Customer Support.

Page 170: Hiperstation Messages and Codes

4-34 Hiperstation Messages and Codes

QQFHPICMQQFHPICM-0026E Error parsing XML file, RC=<return-code> (<function>)

Explanation: The data passed from the client is not a valid XML document. <return-code> indicates the reason for the failure. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPICM-0027E Error in function <Api-call>, RC=<Api-return-code> (<function>)

Explanation: <Api-call> failed with <Api-return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: There may be no required action since a non-zero <Api-return-code> may not indicate an error, only an exception in processing the <Api-call>. See previous messages in log for further information.

QQFHPICM-0028E <tag-name> tag is missing from request (<function>)

Explanation: Hiperstation API call being processed requires <tag-name> present in the XML request. The client application did not include this <tag-name> in the API request. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPICM-0029E Invalid function tag: <tag-name>

Explanation: The XML request received from a client application contains function <tag-name> which is not supported.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPICM-0030E Open of <file> failed (<function>)

Explanation: An attempt to open <file> failed. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that <file> exists and that the user has read authority on the file. If <file> is an MVS dataset, ensure that it is either a sequential dataset or a PDS member.

QQFHPICM-0031E Allocation of <file> failed with error code=<err>, info code=<info> (<function>)

Explanation: Dynamic allocation of <file> failed. <err> and <info> contain the error code and reason code generated by the dynamic allocation function. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check the error code and info code values from the MVS authorized service DYNALLOC.

QQFHPICM-0032E Open of <file> failed, RC=<errno>: <ernno-text>lastop=<last-operation> info code=<info> error=<err> (<function>)

Explanation: An attempt to open file <file> for write access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <last-op> refers to the last I/O operation that was performed as defined in the __last_op field of the __amrc. <err> and <info> contain the error code and reason code generated. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write or update authority on the file. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPICM-0033E Version mismatch, Client Version=<client-version> Server Version=<server-version> (<function>)

Explanation: The <client-version> in the client application is not compatible with the <server-version> in the Hiperstation Server job. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

Page 171: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-35

User Response: Install either an updated client application on the client machine or an update server on the mainframe. On the mainframe, ensure that the Hiperstation Server job is using up-to-date libraries.

QQFHPICM-0054I Starting API function <function>

Explanation: Indicates that an XML request from a client application has been received for API function <function>.

User Response: Informational message. No user action necessary.

QQFHPICM-0057I API function <function> completed, RC=<Api-return-code>

Explanation: The API call <function> has completed. <Api-return-code> indicates an internal return code for the call. Non-zero <Api-return-code> values do not necessarily indicate an error, but just information to the client application.

User Response: Informational message. No user action necessary.

QQFHPICM-0070E Call to internal function <QQFHPIDL | QQFHPIML> failed for <filter | dataset>, RC = <return-code> (<function>)

Explanation: For internal function QQFHPIDL, the <return-code> will be 8 for the <filter> specified on a dataset listing. The job did not have sufficient storage to do a dataset listing. For internal function, QQFHPIML, the return code for the member listing of <dataset> has the following meaning:1: Dataset not found2: Dataset is not a PDS or PDSE3: User is not authorized to use this dataset4: Internal Error - Build5: Internal Error - Close6: Unknown Error<function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: For internal function QQFHPIDL, run Hiperstation Server job with a larger REGION size or specify a more specific filter.For internal function QQFHPIML, do the following based on the return code:1: Ensure that the client application no longer considers that the dataset exists.2: Call support for the client application since it should not request a member listing on a non PDS or PDSE file.3: If the user should be authorized for the dataset, have the security administrator give the user access.4: Call Hiperstation Customer Support.

QQFHPICM-0073W Tag <sub-tag> is not valid for the <super-tag> tag. It will be ignored (<function>)

Explanation: The XML request received from a client application contains an XML tag <sub-tag> that is not valid for tag <super-tag>. This may be due to running out-of-synch versions of the client and server applications. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This should be alright, but it may indicate that the Hiperstation Server job has not been upgraded while the client application has been. Contact the Hiperstation installer to ensure that the Hiperstation Server job is current.

QQFHPIHCQQFHPIHC-0034E Error parsing XML file, RC=<return-code> (<function>)

Explanation: The data passed from the client is not a valid XML document. <return-code> indicates the reason for the failure. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

Page 172: Hiperstation Messages and Codes

4-36 Hiperstation Messages and Codes

User Response: Contact Hiperstation Customer Support.

QQFHPIHC-0035E Version mismatch, Client Version=<client-version> Server Version=<server-version> (<function>)

Explanation: The <client-version> in the client application is not compatible with the <server-version> in the Hiperstation Server job. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Install either an updated client application on the client machine or an update server on the mainframe. On the mainframe, ensure that the Hiperstation Server job is using up-to-date libraries.

QQFHPIHC-0036E Error in function <Api-call>, RC=<Api-return-code> (<function>)

Explanation: <Api-call> failed with <Api-return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational There may be no required action since a non-zero <Api-return-code> may not indicate an error, only an exception in processing the <Api-call>. See previous messages in log for further information.

QQFHPIHC-0037E <tag-name> tag is missing from request (<function>)

Explanation: Hiperstation API call being processed requires <tag-name> present in the XML request. The client application did not include this <tag-name> in the API request. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIHC-0038E Invalid function tag: <tag-name>

Explanation: The XML request received from a client application contains function <tag-name> which is not supported.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIHC-0040E Write to <file> failed, RC=<errno>: <errno-text> (<function>)

Explanation: An error occurred while attempting to write to <file>. <errno> give the POSIX errno and <errno-text> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIHC-0055I Starting API function <function>

Explanation: Indicates that an XML request from a client application has been received for API function <function>.

User Response: Informational message. No user action necessary.

QQFHPIHC-0058I API function <function> completed, RC=<Api-return-code>

Explanation: The API call <function> has completed. <Api-return-code> indicates an internal return code for the call. Non-zero <Api-return-code> values do not necessarily indicate an error.

User Response: Informational message. No user action necessary.

QQFHPIHC-0072W Tag <sub-tag> is not valid for the <super-tag> tag. It will be ignored (<function>)

Explanation: The XML request received from a client application contains an XML tag <sub-tag> that is not valid for tag <super-tag>. This may be due to running out-of-synch versions of the client and server applications. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This should be alright, but it may indicate that the Hiperstation Server job has not been upgraded while the client application has been. Contact the Hiperstation installer to ensure that the Hiperstation Server job is current.

Page 173: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-37

QQFHPIMQQQFHPIMQ-0099E Error parsing XML file, RC=<return-code> (<function>)

Explanation: The data passed from the client is not a valid XML document. <return-code> indicates the reason for the failure. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPIMQ-0100E Version mismatch, Client Version=<client-version> Server Version=<serverversion> (<function>)

Explanation: The <client-version> in the client application is not compatible with the <server-version> in the Hiperstation Server job. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0101E Error in function <Api-call>, RC=<Api-return-code> (<function>)

Explanation: <Api-call> failed with <Api-return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. There may be no required action since a non-zero <Api-returncode> may not indicate an error, only an exception in processing the <Api-call>. See previous messages in log for further information.

QQFHPIMQ-0102E <tag-name> tag is missing from request (<function>)

Explanation: Hiperstation API call being processed requires <tag-name> present in the XML request. The client application did not include this <tag-name> in the API request. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIMQ-0103E Invalid function tag: <tag-name>

Explanation: The XML request received from a client application contains function <tagname> which is not supported.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIMQ-0104E Missing or invalid search criteria (<function>)

Explanation: The XML request received from a client application has one or more incomplete search criteria. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPIMQ-0105E Open of <ddname | file | directory> failed, RC=<errno> <errno-text> (<function>)

Explanation: An attempt to open file <ddname>, <file>, or <directory> for read access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that entity exists and that the user has read authority. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIMQ-0106E <tag> tag has an invalid value of <tag-value>

Explanation: The <tag-value> specified in the XML request from a client application is invalid for <tag>.

User Response: Contact Hiperstation Customer Support.

Page 174: Hiperstation Messages and Codes

4-38 Hiperstation Messages and Codes

QQFHPIMQ-0107E <tag> tag has an unmatched <left | right> parenthesis

Explanation: The XML request received from a client application contains unbalanced parenthesis for a search request.

User Response: Contact Hiperstation Customer Support.

QQFHPIMQ-0108W <directory> does not exist (<function>)

Explanation: <directory> does not currently exist. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0109I Creating search directory <directory> (<function>)

Explanation: A search <directory> will be created for the user. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0110E Creation of <directory> failed, RC=<errno>: <errno-text> (<function>)

Explanation: The creation of <directory> failed. <errno> give the POSIX errno and <errnotext> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write and execute authority for the parent directory for which the new directory is being created. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIMQ-0111E Open of <file> failed, RC=<errno>: <ernno-text> lastop=<last-operation> info code=<info> error=<err> (<function>)

Explanation: An attempt to open file <file> for write access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <last-op> refers to the last I/O operation that was performed as defined in the __last_op field of the __amrc. <err> and <info> contain the error code and reason code generated. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write or update authority on the file. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIMQ-0112I Starting API function <function>

Explanation: Indicates that an XML request from a client application has been received for API function <function>.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0113I API function <function> completed, RC=<Api-return-code>

Explanation: The API call <function> has completed. <Api-return-code> indicates an internal return code for the call. Non-zero <Api-return-code> values do not necessarily indicate an error, but just information to the client application.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0114E User does not have <GRUSER | GRADMIN> authorization (<function>)

Explanation: A user has made a Hiperstation request that requires either GRUSER or GRADMIN authority. See the Hiperstation Installation Guide for more information regarding GRUSER and GRADMIN. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: If the user should be authorized for the function they are attempting to perform, they should be given authority GRADMIN or GRUSER authorization by the security administrator. If not, no action is required.

QQFHPIMQ-0115E Hiperstation MQ is not licensed to run on this machine (<function>)

Explanation: Hiperstation for WebSphere MQ is not licensed on this machine. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact your Compuware Sales Representative.

Page 175: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-39

QQFHPIMQ-0116E Could not get ETRMGPAR variable <parameter> (<function>)

Explanation: A required <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Add the parameter to the Hiperstation panel library member ETRMGPAR.

QQFHPIMQ-0117W <parameter> was not found in ETRMGPAR, default value used (<function>)

Explanation: An optional <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: No user action is required unless the default value for the parameter is not sufficient. If such is the case, add the parameter to the Hiperstation panel library member ETRMGPAR.

QQFHPIMQ-0118E Job submission failed: <reason> (<function>)

Explanation: Job submission failed. Possible <reason> values are as follows:

• Invalid start or end date/time• Error allocating temporary PDSE• Error allocating global record request file• Error opening global record request file• Error allocating the internal reader• Error opening the internal reader• Error closing the internal reader

<function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Following are the user's responses based on the reason:

• Invalid start or end date/time: Correct the start date, start time, end date, and/or end time to valid value. This issue is most likely a problem with the client application.

• Error allocating temporary PDSE: Ensure that the parameters for file allocation in Hiperstation panel library member ETRMGPAR are correct.

• Error allocating global record request file: Ensure that the user has write access to the global record request file.

• Error opening global record request file: Ensure that the user has write access to the global record request file.

• Error allocating the internal reader: Ensure that the user has write access to the internal reader.

• Error opening the internal reader: Ensure that the user has write access to the internal reader.

• Error closing the internal reader: None, the job should have submitted.

QQFHPIMQ-0119I Job <jobname>(<jobnumber>) submitted (<function>)

Explanation: A job has been submitted. <jobname> and <jobnumber> refer to the JES job name and job number that the job may be found. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIMQ-0120E Invalid <start | end> <date | time> specified (<function>)

Explanation: This message indicates that a start date, start time, end date, or end time is correctly specified in the XML request received from a client application. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This is most likely an issue with the client application. Call Hiperstation Customer Support.

QQFHPIMQ-0121E Unable to find <VGBL | VGBE> record <archive-name> (<function>)

Explanation: While processing a search request, the VGBL or VGBE record for the archive <archive-name> could not be found on the global record request file. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

Page 176: Hiperstation Messages and Codes

4-40 Hiperstation Messages and Codes

User Response: Ensure that archive request still exists in the global record request file (perhaps the request was cancelled and the archive repository set deleted just before search request started).

QQFHPIMQ-0122 E Creation of dataset <dataset-name> failed with error code = <err>, info code = <info> (<function>)

Explanation: Unable to create temporary REXX filter dataset. <err> and <info> refer to the error code and info code from the dynamic allocation function. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check the error code and info code values from the MVS authorized service DYNALLOC.

QQFHPIMQ-0123W Tag <sub-tag> is not valid for the <super-tag> tag. It will be ignored (<function>)

Explanation: The XML request received from a client application contains an XML tag <subtag> that is not valid for tag <super-tag>. This may be due to running out-of-synch versions of the client and server applications. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This should be alright, but it may indicate that the Hiperstation Server job has not been upgraded while the client application has been. Contact the Hiperstation installer to ensure that the Hiperstation Server job is current.

QQFHPIMQ-0124E Invalid filters (<filter-flag>)

Explanation: While saving the Websphere MQ search criteria, one of the elements of an MQ Filter is missing. <filter-flag> indicates which filter elements are present.

User Response: Call Hiperstation Customer Support.

QQFHPITPQQFHPITP-0074E Error parsing XML file, RC=<return-code> (<function>)

Explanation: The data passed from the client is not a valid XML document. <return-code> indicates the reason for the failure. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPITP-0075E Version mismatch, Client Version=<client-version> Server Version=<serverversion> (<function>)

Explanation: The <client-version> in the client application is not compatible with the <server-version> in the Hiperstation Server job. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPITP-0076E Error in function <Api-call>, RC=<Api-return-code> (<function>)

Explanation: <Api-call> failed with <Api-return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational There may be no required action since a non-zero <Api-returncode> may not indicate an error, only an exception in processing the <Api-call>. See previous messages in log for further information.

QQFHPITP-0077E <tag-name> tag is missing from request (<function>)

Explanation: Hiperstation API call being processed requires <tag-name> present in the XML request. The client application did not include this <tag-name> in the API request. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

Page 177: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-41

QQFHPITP-0078E Invalid function tag: <tag-name>

Explanation: The XML request received from a client application contains function <tagname> which is not supported.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPITP-0079E Missing or invalid search criteria (<function>)

Explanation: The XML request received from a client application has one or more incomplete search criteria. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPITP-0080E Open of <ddname | file | directory> failed, RC=<errno> <errno-text> (<function>)

Explanation: An attempt to open file <ddname>, <file>, or <directory> for read access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that entity exists and that the user has read authority. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPITP-0081E <tag> tag has an invalid value of <tag-value>

Explanation: The <tag-value> specified in the XML request from a client application is invalid for <tag>.

User Response: Contact Hiperstation Customer Support.

QQFHPITP-0082E <tag> tag has an unmatched <left | right> parenthesis

Explanation: The XML request received from a client application contains unbalanced parenthesis for a search request.

User Response: Contact Hiperstation Customer Support.

QQFHPITP-0083W <directory> does not exist (<function>)

Explanation: <directory> does not currently exist. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPITP-0084I Creating search directory <directory> (<function>)

Explanation: A search <directory> will be created for the user. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPITP-0085E Creation of <directory> failed, RC=<errno>: <errno-text> (<function>)

Explanation: The creation of <directory> failed. <errno> give the POSIX errno and <errnotext> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write and execute authority for the parent directory for which the new directory is being created. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPITP-0086E Open of <file> failed, RC=<errno>: <ernno-text> lastop=<last-operation> info code=<info> error=<err> (<function>)

Explanation: An attempt to open file <file> for write access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <last-op> refers to the last I/O operation that was performed as defined in the __last_op field of the __amrc. <err> and <info> contain the error code and reason code generated. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write or update authority on the file. Consult the IBM UNIX System Services manuals for more information on errno.

Page 178: Hiperstation Messages and Codes

4-42 Hiperstation Messages and Codes

QQFHPITP-0087I Starting API function <function>

Explanation: Indicates that an XML request from a client application has been received for API function <function>.

User Response: Informational message. No user action necessary.

QQFHPITP-0088I API function <function> completed, RC=<Api-return-code>

Explanation: The API call <function> has completed. <Api-return-code> indicates an internal return code for the call. Non-zero <Api-return-code> values do not necessarily indicate an error, but just information to the client application.

User Response: Informational message. No user action necessary.

QQFHPITP-0089E User does not have <GRUSER | GRADMIN> authorization (<function>)

Explanation: A user has made a Hiperstation request that requires either GRUSER or GRADMIN authority. See the Hiperstation Installation Guide for more information regarding GRUSER and GRADMIN. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: If the user should be authorized for the function they are attempting to perform, they should be given authority GRADMIN or GRUSER authorization by the security administrator. If not, no action is required.

QQFHPITP-0090E Hiperstation TCP is not licensed to run on this machine (<function>)

Explanation: Hiperstation for Mainframe Servers is not licensed on this machine. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact your Compuware Sales Representative.

QQFHPITP-0091E Could not get ETRMGPAR variable <parameter> (<function>)

Explanation: A required <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Add the parameter to the Hiperstation panel library member ETRMGPAR.

QQFHPITP-0092W <parameter> was not found in ETRMGPAR, default value used (<function>)

Explanation: An optional <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: No user action is required unless the default value for the parameter is not sufficient. If such is the case, add the parameter to the Hiperstation panel library member ETRMGPAR.

QQFHPITP-0093E Job submission failed: <reason> (<function>)

Explanation: Job submission failed. Possible <reason> values are as follows:

• Invalid start or end date/time• Error allocating temporary PDSE• Error allocating global record request file• Error opening global record request file• Error allocating the internal reader• Error opening the internal reader• Error closing the internal reader

<function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Following are the user's responses based on the reason:

• Invalid start or end date/time: Correct the start date, start time, end date, and/or end time to valid value. This issue is most likely a problem with the client application.

• Error allocating temporary PDSE: Ensure that the parameters for file allocation in Hiperstation panel library member ETRMGPAR are correct.

• Error allocating global record request file: Ensure that the user has write access to the global record request file.

Page 179: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-43

• Error opening global record request file: Ensure that the user has write access to the global record request file.

• Error allocating the internal reader: Ensure that the user has write access to the internal reader.

• Error opening the internal reader: Ensure that the user has write access to the internal reader.

• Error closing the internal reader: None, the job should have submitted.

QQFHPITP-0094I Job <jobname>(<jobnumber>) submitted (<function>)

Explanation: A job has been submitted. <jobname> and <jobnumber> refer to the JES job name and job number that the job may be found. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPITP-0095E Invalid <start | end> <date | time> specified (<function>)

Explanation: This message indicates that a start date, start time, end date, or end time is correctly specified in the XML request received from a client application. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This is most likely an issue with the client application. Call Hiperstation Customer Support.

QQFHPITP-0096E Unable to find <VGBL | VGBE> record <archive-name> (<function>)

Explanation: While processing a search request, the VGBL or VGBE record for the archive <archive-name> could not be found on the global record request file. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that archive request still exists in the global record request file (perhaps the request was cancelled and the archive repository set deleted just before search request started).

QQFHPITP-0097E Creation of dataset <dataset-name> failed with error code = <err>, info code = <info> (<function>)

Explanation: Unable to create temporary REXX filter dataset. <err> and <info> refer to the error code and info code from the dynamic allocation function. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Check the error code and info code values from the MVS authorized service DYNALLOC.

QQFHPITP-0098W Tag <sub-tag> is not valid for the <super-tag> tag. It will be ignored (<function>)

Explanation: The XML request received from a client application contains an XML tag <subtag> that is not valid for tag <super-tag>. This may be due to running out-of-synch versions of the client and server applications. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This should be alright, but it may indicate that the Hiperstation Server job has not been upgraded while the client application has been. Contact the Hiperstation installer to ensure that the Hiperstation Server job is current.

QQFHPIUTQQFHPIUT-0025E <parameter> not found in ETRMGPAR (<function>)

Explanation: Unable to find <parameter> in ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Need to add <parameter> to ETRMGPAR with an appropriate value.

QQFHPIUT-0062E Call to ETRMDCPS failed

Explanation: Unable to perform Compuware license validation.

User Response: Contact Hiperstation Customer Support.

Page 180: Hiperstation Messages and Codes

4-44 Hiperstation Messages and Codes

QQFHPIVTQQFHPIVT-0042E Version mismatch, Client Version=<client-version> Server Version=<server-version> (<function>)

Explanation: The <client-version> in the client application is not compatible with the <server-version> in the Hiperstation Server job. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIVT-0043E Error in function <Api-call>, RC=<Api-return-code> (<function>)

Explanation: <Api-call> failed with <Api-return-code>. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: There may be no required action since a non-zero <Api-return-code> may not indicate an error, only an exception in processing the <Api-call>. See previous messages in log for further information.

QQFHPIVT-0044E <tag-name> tag is missing from request (<function>)

Explanation: The Hiperstation API call being processed requires <tag-name> present in the XML request. The client application did not include this <tag-name> in the API request. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIVT-0045E Invalid function tag: <tag-name>

Explanation: The XML request received from a client application contains function <tag-name> which is not supported.

User Response: Ensure that the client application is compatible with the version of the Hiperstation Server job.

QQFHPIVT-0046E Missing or invalid search criteria (<function>)

Explanation: The XML request received from a client application has one or more incomplete search criteria. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact Hiperstation Customer Support.

QQFHPIVT-0047E Open of <ddname | file | directory> failed, RC=<errno> <errno-text> (<function>)

Explanation: An attempt to open file <ddname>, <file>, or <directory> for read access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that entity exists and that the user has read authority. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIVT-0048E <tag> tag has an invalid value of <tag-value>

Explanation: The <tag-value> specified in the XML request from a client application is invalid for <tag>.

User Response: Contact Hiperstation Customer Support.

QQFHPIVT-0049E <tag> tag has an unmatched <left | right> parenthesis

Explanation: The XML request received from a client application contains unbalanced parenthesis for a search request.

User Response: Contact Hiperstation Customer Support

QQFHPIVT-0050W <directory> does not exist (<function>)

Explanation: <directory> does not currently exist. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

Page 181: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-45

User Response: Informational message. No user action necessary.

QQFHPIVT-0051I Creating search directory <directory> (<function>)

Explanation: A search <directory> will be created for the user. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIVT-0052E Creation of <directory> failed, RC=<errno>: <errno-text> (<function>)

Explanation: The creation of <directory> failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write and execute authority for the parent directory for which the new directory is being created. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIVT-0053E Open of <file> failed, RC=<errno>: <ernno-text> lastop=<last-operation> info code=<info> error=<err> (<function>)

Explanation: An attempt to open file <file> for write access failed. <errno> give the POSIX errno and <errno-text> the string value of the error. <last-op> refers to the last I/O operation that was performed as defined in the __last_op field of the __amrc. <err> and <info> contain the error code and reason code generated. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that the user has write or update authority on the file. Consult the IBM UNIX System Services manuals for more information on errno.

QQFHPIVT-0056I Starting API function <function>

Explanation: Indicates that an XML request from a client application has been received for API function <function>.

User Response: Informational message. No user action necessary.

QQFHPIVT-0059I API function <function> completed, RC=<Api-return-code>

Explanation: The API call <function> has completed. <Api-return-code> indicates an internal return code for the call. Non-zero <Api-return-code> values do not necessarily indicate an error.

User Response: Informational message. No user action necessary.

QQFHPIVT-0060E User does not have <GRUSER | GRADMIN> authorization (<function>)

Explanation: A user has made a Hiperstation request that requires either GRUSER or GRADMIN authority. See the Hiperstation Installation Guide for more information regarding GRUSER and GRADMIN. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: If the user should be authorized for the function they are attempting to perform, they should be given authority GRADMIN or GRUSER authorization by the security administrator. If not, no action is required.

QQFHPIVT-0061E <Hiperstation VTAM> is not licensed to run on this machine (<function>)

Explanation: Hiperstation for VTAM is not licensed on this machine. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Contact your Compuware Sales Representative.

QQFHPIVT-0063E Could not get ETRMGPAR variable <parameter> (<function>)

Explanation: A required <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Add the parameter to the Hiperstation panel library member ETRMGPAR.

Page 182: Hiperstation Messages and Codes

4-46 Hiperstation Messages and Codes

QQFHPIVT-0064W <parameter> was not found in ETRMGPAR, default value used (<function>)

Explanation: An optional <parameter> does not exist in the Hiperstation panel library member ETRMGPAR. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: No user action is required unless the default value for the parameter is not sufficient. If such is the case, add the parameter to the Hiperstation panel library member ETRMGPAR.

QQFHPIVT-0065E Job submission failed: <reason> (<function>)

Explanation: Job submission failed. Possible <reason> values are as follows:

• Invalid start or end date/time• Error allocating temporary PDSE• Error allocating global record request file• Error opening global record request file• Error allocating the internal reader• Error opening the internal reader• Error closing the internal reader• <function> refers to the function that generated the message and is only for Hiperstation

diagnostic purposes.

User Response: Following are the user's responses based on the reason:

• Invalid start or end date/time: Correct the start date, start time, end date, and/or end time to valid value. This issue is most likely a problem with the client application.

• Error allocating temporary PDSE: Ensure that the parameters for file allocation in Hiperstation panel library member ETRMGPAR are correct.

• Error allocating global record request file: Ensure that the user has write access to the global record request file.

• Error opening global record request file: Ensure that the user has write access to the global record request file.

• Error allocating the internal reader: Ensure that the user has write access to the internal reader.

• Error opening the internal reader: Ensure that the user has write access to the internal reader.

• Error closing the internal reader: None, the job should have submitted.

QQFHPIVT-0066I Job <jobname>(<jobnumber>) submitted (<function>)

Explanation: A job has been submitted. <jobname> and <jobnumber> refer to the JES job name and job number that the job may be found. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Informational message. No user action necessary.

QQFHPIVT-0067E Invalid <start | end> <date | time> specified (<function>)

Explanation: This message indicates that a start date, start time, end date, or end time is correctly specified in the XML request received from a client application. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This is most likely an issue with the client application. Call Hiperstation Customer Support.

QQFHPIVT-0068E Unable to find <VGBL | VGBE> record <archive-name> (<function>)

Explanation: While processing a search request, the VGBL or VGBE record for the archive <archive-name> could not be found on the global record request file. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: Ensure that archive request still exists in the global record request file (perhaps the request was cancelled and the archive repository set deleted just before search request started).

QQFHPIVT-0069E Creation of dataset <dataset-name> failed with error code = <err>, info code = <info> (<function>)

Explanation: Unable to create temporary REXX filter dataset. <err> and <info> refer to the error code and info code from the dynamic allocation function. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

Page 183: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-47

User Response: Check the error code and info code values from the MVS authorized service DYNALLOC.

QQFHPIVT-0071W Tag <sub-tag> is not valid for the <super-tag> tag. It will be ignored (<function>)

Explanation: The XML request received from a client application contains an XML tag <sub-tag> that is not valid for tag <super-tag>. This may be due to running out-of-synch versions of the client and server applications. <function> refers to the function that generated the message and is only for Hiperstation diagnostic purposes.

User Response: This should be alright, but it may indicate that the Hiperstation Server job has not been upgraded while the client application has been. Contact the Hiperstation installer to ensure that the Hiperstation Server job is current.

QQFVCONVQQFVCONV-0001I Vantage data conversion initiated

Explanation: The conversion of Vantage Agentless vdata and hdata files into a Hiperstation repository has begun.

User Response: Informational message. No user action necessary.

QQFVCONV-0002I Ignore data from IP Address <ip-address>

Explanation: The user specified on the PARM parameter of the QQFVCONV program to ignore all activity from IP Address <ip-address>.

User Response: Informational message. No user action necessary.

QQFVCONV-0003I <total-records> Records read from vData file

Explanation: <total-records> indicates how many records were read from the Vantage Agentless vdata file.

User Response: Informational message. No user action necessary.

QQFVCONV-0004E Unable to open <repository | hdata | vdata> file

Explanation: While attempting to open either the Hiperstation repository dataset or the Vantage hdata or vdata file, an open error occurred.

User Response: Some common problems are the file/dataset does not have proper authority for the access required or the dataset is in use by another program.

QQFVCONV-0005I Vantage data conversion completed. RC=<return-code>

Explanation: The XML request received from a client application contains function <tagname> which is not supported.

User Response: Informational message. No user action necessary.

QQFVCONV-0012W <vdata | hdata> version <version> not supported

Explanation: The version of the vdata/hdata file is not supported by the Hiperstation-Vantage Agentless conversion program. The conversion will be attempted.

User Response: Ensure the conversion ran without error.

QQFVCONV-0013I <total-records> records written to the repository file

Explanation: <total-records> indicates the number of converted records written to the Hiperstation repository dataset.

User Response: Informational message. No user action necessary.

QQFVCONV-0017E vdata record out of sequence (repository="<gmt_time1>" vdata="<gmt_time2>")

Explanation: The first record on the vdata file has a timestamp that is earlier than the last timestamp for the Archive Record request (based on the name of the repository dataset) to which you are adding. <gmt_time1> represents the end time of the last segment added to the

Page 184: Hiperstation Messages and Codes

4-48 Hiperstation Messages and Codes

Archive Record request. <gmt_time2> represents the time on the vdata record. The conversion will terminate.

User Response: Only add repositories in time order sequence. This repository cannot be added to the Archive Record request.

QQFVCONV-0018E The repository dataset must end with .IMPORTDS

Explanation: The repository dataset does not end with .IMPORTDS and it should.

User Response: Rename the repository dataset so that it ends with .IMPORTDS.

QQFVDATAQQFVDATA-0008W Unknown field <filed-name> found

Explanation: A field called <field-name> was found on the Vantage vdata file's Field description record that is not recognized by the conversion program. This can happen if the version of the vdata file is not supported by Hiperstation's Vantage conversion program.

User Response: Ensure the conversion ran without error.

QQFVDATA-0009E Field number <field-number> is undefined

Explanation: A record was read that contains more fields than the Vantage vdata file's Field description record.

User Response: Contact Vantage Agentless Customer Support.

QQFVDATA-0010E Unable to open codepage converters (<to-codepage>:<from-codepage>)

Explanation: Unable to establish the code page conversion between the Vantage Agentless files from <from-codepage> (EBCDIC - because of being FTPed from Vantage AMD to the mainframe as text) and the Hiperstation repository dataset to <to-codepage>(ASCII) using the iconv_open function in IBM's iconv utility.

User Response: Ensure that the ETRMGPAR dataset on the SQQFPENU DD contains the proper <from-codepage> codepage as well the <to-codepage> codepage in profiling (check the site profile for the user's userid and then the default profile if the userid profile is not present). Also ensure that IBM's iconv utility supports the specified conversion.

QQFVDATA-0011E Codepage conversion failed

Explanation: IBM's iconv utility generated a failure when attempting to convert data from the Vantage Agentless files.

User Response: Contact Hiperstation Customer Support.

QQFVDATA-0014W Matching headerdata record not found (<hitId>)

Explanation: The ClientVantage Agentless vdata record with the value of <hitId> in the hitId field does not have a matching record in the ClientVantage Agentless headerdata file. This record will not be written to the Hiperstation repository dataset.

User Response: Check to see if there were any records written to the Hiperstation repository. If no records were written the repository, this could signify that the vdata and headerdata files are not for the same sessions.

QQFVDATA-0015E Required vdata field <field> not present

Explanation: The ClientVantage Agentless vdata file is missing a field required to perform the conversion.

User Response: Check the ClientVantage Agentless AMD to ensure it is configured to include this field in its vdata files.

QQFHDATA-0016E Required headerdata field <field> not present

Explanation: The ClientVantage Agentless headerdata file is missing a field required to perform the conversion.

User Response: Check the ClientVantage Agentless AMD to ensure it is configured to include this field in its headerdata files.

Page 185: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-49

RGSTRYGNRGSTRYGN-0047I Registry dataset is out of space

Explanation: The Registry dataset has become full and has used all available extents.

User Response: None. Informational only.

RGSTRYGN-0048I Attempting to create a larger dataset

Explanation: The Registry Generator program is going to create a new Registry dataset and copy the contents of the original to the new one.

User Response: None. Informational only.

RGSTRYGN-0049I Copying Registry data to new dataset

Explanation: The above copy process is in progress.

User Response: None. Informational only.

RGSTRYGN-0050I Registry dataset successfully enlarged

Explanation: The creation of a new dataset and the copying of the original to the new is complete.

User Response: None. Informational only.

RGSTRYGN-0051E xxxxxx not a valid Registry name.

Explanation: The first parameter on the EXEC statement is not a valid dataset name.

User Response: None. Informational only.

RGSTRYGN-0054E Registry dataset already exists.

Explanation: An attempt to create a new Registry dataset failed. See the IDCAMS messages for more information.

User Response: Increase the space parameters in the ETRMGPAR parameter member and manually resubmit the job.

RGSTRYGN-0055E xxxxxx registry not found.

Explanation: The Registry dataset does not exist or is not in the catalog.

User Response: Re-create the Registry dataset by submitting the job manually with a second parameter of 0.

RGSTRYGN-0056E Registry RC = nnnnn, errcode = nnnnn

Explanation: This is the return code and errcode from an I/O operation.

User Response: See accompanying messages for more information.

RGSTRYGN-0058E Repository segment xxxxxx

Explanation: Identifies the Registry dataset for subsequent messages.

User Response: See accompanying messages for more information.

RGSTRYGN-0059E Repository open failure RC = nnnnn, errcode = nnnnn

Explanation: The Repository dataset cannot be opened. Above is the return code and error code.

User Response: See accompanying messages for more information.

RGSTRYGN-0060E The Registry is in use by another task.

Explanation: The Registry dataset is opened and in use by another task.

User Response: Rerun the Registry Generation program when the Registry dataset is not in use.

Page 186: Hiperstation Messages and Codes

4-50 Hiperstation Messages and Codes

RGSTRYGN-0061E Registry Update cancelled

Explanation: The Registry Generation is terminated. See additional error information.

RGSTRYGN-0062W Repository Segment xxxxxx is already in the Registry

Explanation: The above Repository segment is already in the Registry.

RGSTRYGN-0063E Error creating the Registry file. See IDCAMS messages

Explanation: An error occurred in the IDCAMS program.

User Response: See IDCAMS messages for further information.

RGSTRYGN-0064I Previous segment number nnnnn missing from the Registry

Explanation: Before adding the requested Repository segment information to the Registry, a check is made to ensure that the previous 5 Repository segments are in the Repository. If any are missing an attempt to add them is performed.

User Response: None. Informational only.

RGSTRYGN-0065I Adding missing segment to the Registry

Explanation: A Repository segment was found to be missing. It is will be added to the Registry.

User Response: None. Informational only.

RGSTRYGN-0066E Existing Registry dataset cannot be deleted

Explanation: An error has occurred when attempting to delete an existing Registry dataset.

User Response: See the IDCAMS messages for more information.

RGSTRYGN-0067W Error renaming the Registry file. See IDCAMS messages

Explanation: While copying the Registry file to a larger one, an error occurred when attempting to rename the new Registry file to the original name. The new Registry file is complete. It's name is the original Registry name with a suffix of .TEMP.

User Response: You can rename the dataset to the original name after correcting the error. See the IDCAMS messages for more information.

RGSTRYGN-0068I Add missing segment to the Registry failed

Explanation: While attempting to add a missing Repository segment to the Registry, an I/O error occurred.

User Response: Run the RGSTRYGN job for the missing segment.

RGSTRYGN-0069I Repository Segment XXXXXXXX contains no complete record

Explanation: The specified Repository dataset does not have any complete transactions and is, most likely, empty.

User Response: Information only. The specified Repository Segment is not added to the Registry.

RGSTRYGN-0083I Repository dataset <segment number> not found.

Explanation: The Repository dataset cannot be located.

System Action: The Repository Segment is not added to the Registry.

RGSTRYGN-0563E Too many parameters xxxxxx. Only 2 allowed.

Explanation: Only one or two parameters can be provided.

User Response: Correct and manually resubmit.

RGSTRYGN-0564E Invalid VSAM allocation space units.

Explanation: The information in the parameter member ETRMGPAR is invalid.

User Response: Correct and manually resubmit.

Page 187: Hiperstation Messages and Codes

Hiperstation Messages: HSPFE through RGSTRYGN 4-51

RGSTRYGN-0565E Registry DSN PARM is missing.

Explanation: The first parameter is missing.

User Response: Correct and manually resubmit.

Page 188: Hiperstation Messages and Codes

4-52 Hiperstation Messages and Codes

Page 189: Hiperstation Messages and Codes

5-1

Chapter 5.

5Hiperstation Messages: SCRTCP through SYSPLEX Chap 5

The chapter explains messages with prefix SCRTCP through prefix SVXX and, if applicable, provides response actions you can take to resolve the issue causing the message. Messages are listed in alpha-numeric order and grouped by prefix. Use the “Contents” to help you find the message information you need.

SCRTCPSCRTCP-0400I Hiperstation TCP/IP Script Creation <version> <build>

Explanation: Informational message.

SCRTCP-0401I Executed with <product> Version <num> Release <num> Modification <num>

Explanation: Informational message.

SCRTCP-0402E Storage could not be allocated for <structure name> structure.

Explanation: The storage required to create the named structure was not available.

System Action: Script Create terminates.

User Response: Increase region size and execute script creation again. If the problem persists, contact Compuware Customer Support.

SCRTCP-0403E Creation of the Global Hash Table failed.

Explanation: The C hcreate() function failed to define the Global Hash Table.

System Action: Script Create terminates.

User Response: Increase region size and execute script creation again. If the problem persists, contact Compuware Customer Support.

SCRTCP-0404I Input Parameters being read from DDname: <ddname>

Explanation: Informational message

SCRTCP-0405E <ddname> file of input parameters could not be opened.

Explanation: Script Create could not open the file containing the input parameters.

System Action: Script Create terminates.

User Response: Ensure that dataset name was correctly specified on the SYSIN DD. Verify that it is a fixed block dataset with an LRECL of 80. If the problem persists, contact Compuware Customer Support.

SCRTCP-0406E Open of initial segment in repository set <dataset_name> failed.

Explanation: Script Create could not open the first or only dataset in the input repository set specification.

System Action: Script Create terminates.

User Response: Ensure that the SYSIN TCPCSODN parameter is entered correctly and is a valid Hiperstation for Mainframe Servers repository. If the problem persists, contact Compuware Customer Support.

Page 190: Hiperstation Messages and Codes

5-2 Hiperstation Messages and Codes

SCRTCP-0407I Return code = <RC>

Explanation: Informational message.

SCRTCP-0408I Subset Repository successfully created.

Explanation: Informational message

SCRTCP-0409W No Scripts were created.

Explanation: Warning message.

User Response: Review the filtering criteria and input repository to ensure that they were specified correctly.

SCRTCP-0410I Created <n> PDSE members.

Explanation: Informational message.

SCRTCP-0411W No repository records matched filter criteria.

Explanation: Warning message.

User Response: Review the filtering criteria and input repository to ensure that they were specified correctly.

SCRTCP-0412W The repository is empty.

Explanation: Warning message

User Response: Verify that the input repository was specified correctly. If so, browse the repository dataset to determine whether it contains records from a TCP script capture.

SCRTCP-0413E Invalid Grouping option, exiting(<num>)

Explanation: Script Create SYSIN parameter TCPCSGRP contained an invalid value.

System Action: Script Create terminates.

User Response: Correct the TCPCSGRP parameter value and run Script Create again. Valid values are: 1 one script containing all of the activity, 2 one script for each connection, or 3 one script for each combination of specified criteria. Refer to Hiperstation for Mainframe Servers User Guide for more information on script grouping. If the value is valid, contact Compuware Customer Support.

SCRTCP-0414E Invalid Grouping option, exiting(<num>)

Explanation: Script Create SYSIN parameter TCPCSGRP contained an invalid value.

System Action: Script Create terminates.

User Response: Verify that the SYSIN TCPCSGRP parameter was entered correctly and is valid. If TCPCSGRP is valid, contact Compuware Customer Support.

SCRTCP-0415E A valid capture file name must be specified.

Explanation: An unallocated dataset name must be provided, via the TCPCSODN SYSIN card, for use as the dynamically created subset repository specification.

RC Description and User Response

0 Scripts were created successfully.

4

A warning or error occurred that warrants further investigation. To determine the cause of this return code, review the messages that were issues prior to this message. This return code typically indicates that Script Create had to synthesize events that were not captured in the repository. Browse the scripts to ensure that they correct.

8An error was encountered that must be corrected to have reliable scripts. To determine the cause of this return code, review the messages that were issues prior to this message.

12A severe error was encountered that must be corrected to have reliable scripts. To determine the cause of this return code, review the messages that were issues prior to this message. For further assistance, contact Compuware Customer Support.

Page 191: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-3

System Action: Script Create terminates.

User Response: Verify the TCPCSODN SYSIN parameter. If the problem persists, contact Compuware Customer Support.

SCRTCP-0416E Output repository segment <repository_segment> already exists.

Explanation: Script create could not create the specified output repository segment/dataset because it already exists.

System Action: Script Create terminates.

User Response: Specify a TCPCSODN SYSIN parameter for an output repository set where the segments do not already exist.

SCRTCP-0417E Dynalloc() failed. rc: <value>, error: <value>, info: <value>

Explanation: The dynamic allocation of the capture file failed. The rc (return code), error (error code) and info (information code) values can be looked up in the IBM z/OS MVS Programming Authorized Services Assembler Guide manual.

System Action: Script Create terminates.

User Response: Verify that the dataset named on the TCPCSODN SYSIN parameter does not already exist. Verify that all of the other dataset allocation parameters are valid and do not contradict each other. If the problem persists, contact Compuware Customer Support.

SCRTCP-0418E Fwrite() to output subset repository <dataset_name> failed.

Explanation: A write to an output repository dataset failed without being at end-of-file.

System Action: Script Create terminates.

User Response: Contact Compuware Customer Support.

SCRTCP-0419E Dataset <dataset> failed to open.

Explanation: Script create could not open the named dataset for validation.

System Action: Script Create terminates.

User Response: Verify that the dataset name is correct and is available for opening. If the problem persists, contact Compuware Customer Support.

SCRTCP-0420E Dataset <dataset> has invalid characteristic for a Script Create PDSE

Explanation: Script create datasets for script and log members must be PDSEs with a Variable record formant (recfm) and a record length (lrecl) of at least 76 characters.

System Action: Script Create terminates.

User Response: Verify that the dataset name is correct and that the dataset has the required characteristics. If the problem persists, contact Compuware Customer Support.

SCRTCP-0421E Fldata() for dataset <dataset> failed with return code <number>.

Explanation: Script create could not examine the named dataset's characteristics with the supplied fldata() function.

System Action: Script Create terminates.

User Response: Verify that the dataset name is correct and is available for examination. If the problem persists, contact Compuware Customer Support.

SCRTCP-0422E Fwrite() wrote a partial record, <num> of <num> characters requested.

Explanation: Script create failed to completely write a record to a PDSE member.

System Action: Script Create terminates.

User Response: Increase the size of the temporary Script dataset allocation parameters used by Script Create. These are located in SQQFPENU member ETRMGPAR. These changes may have to be done by the product installer. If the problem persists, contact Compuware Customer Support.

SCRTCP-0423I Log member <member> created in dataset <dataset>

Explanation: Informational message.

Page 192: Hiperstation Messages and Codes

5-4 Hiperstation Messages and Codes

System Action: None.

User Response: None.

SCRTCP-0424E Log statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the log member in the named dataset.

System Action: Script Create terminates.

User Response: Verify that the log dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRTCP-0425E Invalid Repository record ignored, type(<num>, rec#(<num>)

Explanation: Script create discovered an input repository record with an unknown type. For script create purposes, this record is ignored.

System Action: Script Create proceeds.

User Response: Note the events surrounding the message and contact Compuware Customer Support.

SCRTCP-0426E Output repository set <repository_set> is full.

Explanation: Script create has filled up the output repository set. Remaining input repository records eligible for output will not be written.

System Action: Script Create terminates.

User Response: Specify a larger output repository set, either by increasing the FIRST..LAST range, increasing the primary and/or secondary space values or by altering the space unit value.c

SCRTCP-0427E First write to output repository segment <repository_set> failed, return code: <number>.

Explanation: The first fwrite() to an output repository segment failed with the noted return code.

System Action: Script Create terminates.

User Response: Validate the subset/output repository set specification, particularly the dataset naming convention, to ensure that the correct names and dataset characteristics are used. If the problem persists, contact Compuware Customer Support.

SCRTCP-0428E Could not obtain unique member name after <num> tries.

Explanation: Script create could not obtain a member name in the target dataset for scripts, details or log after the noted number of attempts.

System Action: Script Create terminates.

User Response: Review the specification of the prefix and suffix values on required datasets for generated scripts, details or log members. Ensure there is available name space in the specified datasets for member names synthesized by Script Create.

SCRTCP-0429E Output <dataset_member> member could not be opened by fopen().

Explanation: The named dataset and member combination could not be opened.

System Action: Script Create terminates.

User Response: Determine why members in the named dataset cannot be opened. If the problem persists, contact Compuware Customer Support.

SCRTCP-0430W Missing data for Connection: Close seen.

Explanation: Script Create encountered a TCP CLOSE datastream before it encountered a TCP CONNECT datastream. This typically occurs when TCP global recording begins after the application being recorded has already transmitted some data.

System Action: Start the recording session before the application being captured begins transmitting data.

Page 193: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-5

User Response: Start the recording session before the application being captured begins transmitting data.

SCRTCP-0431W No SSL data in repository for HTTPS Connection, ID=<num> Script <member>

Explanation: The script creation request is for the HTTPS protocol, but there is no HTTPS data (HTTP plus SSL) for this connection. This can occur if the global recording started task is not configured to capture SSL data (the SSL parameter in the JCL SYSIN file is absent, if the IBM system SSL routines are not preloaded into the MVS link pack area, if the UNIX “sticky” bit is not set on the IBM SKIT.DLL module, or if the web server was started before any of the previous configuration settings were established. This message can also occur, of course, if no HTTPS data actually flowed for this connection.

System Action:

User Response: Verify that you have requested HTTPS connections in the script creation request that truly use SSL and verify that the necessary global recording and OS/390 configuration settings are established in the correct order. Refer to the Hiperstation Installation and Configuration Guide for detailed instructions on configuring Global Record and your OS/390 system for the capture and playback of HTTPS (SSL) datastreams.

SCRTCP-0432W Missing Data for Connection: Data seen.

Explanation: Script Create encountered a TCP DATA datastream before it encountered a TCP connect datastream. This typically occurs when TCP global recording begins after the application being recorded has already transmitted some data.

System Action: Start the recording session before the application being captured begins transmitting data.

User Response: Start the recording session before the application being captured begins transmitting data.

SCRTCP-0433E Cannot retrieve control block representing new connection.

Explanation: The creation or location of the internal control block representing a new connection has failed.

System Action: Script Create terminates.

User Response: Contact Compuware Customer Support.

SCRTCP-0434E Cannot locate Script control block from associated connection control block.

Explanation: The creation or location of the internal control block representing a script has failed.

System Action: Script Create terminates.

User Response: Contact Compuware Customer Support.

SCRTCP-0435E Cannot retrieve control block representing new connection flags.

Explanation: The creation or location of the internal control block representing the status flags for a new connection has failed.

Code Description

0 Scripts were created successfully.

4Something occurred that warrants further investigation. See earlier messages that were issued for details causing this return code. Scripts may or may not have been created as expected.

8

An error was encountered that must be corrected to have reliable scripts. See earlier messages that were issued for details causing this return code. Scripts will probably not have been created as expected. A return code of 8 usually indicates a problem that can be corrected by the user.

12

A severe error was encountered that must be corrected to have reliable scripts. See earlier messages that were issued for details causing this return code. Scripts will probably not have been created as expected. A return code of 12 usually indicates an unexpected problem that cannot be corrected by the user.

Page 194: Hiperstation Messages and Codes

5-6 Hiperstation Messages and Codes

System Action: Script Create terminates.

User Response: Contact Compuware Customer Support.

SCRTCP-0436I Script member <member> created in dataset <dataset>

Explanation: Informational message.

System Action: None.

User Response: None.

SCRTCP-0437E Script statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the script member in the named dataset.

System Action: Script Create terminates.

User Response: Verify that the script dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRTCP-0438I Combined detail member <member> created in dataset <dataset>

Explanation: Informational message.

System Action: None.

User Response: None.

SCRTCP-0439E Combined detail statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the combined detail member in the named dataset.

System Action: Script Create terminates.

User Response: Verify that the combined detail dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRTCP-0440I Client detail member <member> created in dataset <dataset>

Explanation: Informational message.

System Action: None.

User Response: None.

SCRTCP-0441E Client detail statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the client detail member in the named dataset.

System Action: Script Create terminates.

User Response: Verify that the client detail dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRTCP-0442I Server detail member <member> created in dataset <dataset>

Explanation: Informational message.

System Action: None.

User Response: None.

SCRTCP-0443E Server detail statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the server detail member in the named dataset.

System Action: Script Create terminates.

User Response: Verify that the server detail dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

Page 195: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-7

SCRTCP-0444E Invalid TCPCSDS SYSIN parameter value: <number>

Explanation: The TCPCSDS SYSIN parameter has a value outside its normal range of 1 to 3, inclusive.

System Action: Script Create terminates.

User Response: Verify that the TCPCSDS SYSIN parameter has a value within the specified range. If the problem persists, contact Compuware Customer Support.

SCRTCP-0445E Output repository segment <dataset_name> dynamic allocation failed.

Explanation: Script Create could not dynamically create the output repository dataset.

System Action: Script Create terminates.

User Response: Verify that the SYSIN repository set allocation parameters are valid and meet local site standards. If the problem persists, contact Compuware Customer Support.

SCRTCP-0446W Parameter name is missing from SYSIN input line <input_line>

Explanation: Script create cannot locate a valid SYSIN parameter name from the data in the displayed line of SYSIN input.

System Action: Script Create ignores this SYSIN line.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0447E Unknown SYSIN parameter name <name> located.

Explanation: Script Create terminates.

System Action: None.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0448E Parameter <parm_name> dataset <value> has a first or final character period.

Explanation: The named parameter is a dataset name and it is illegal for a dataset to have a period (.) as the first or last character.

System Action: Script Create terminates.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0449E Parameter <parm_name> dataset <value> has consecutive periods.

Explanation: The named parameter is a dataset name and it is illegal for a dataset to have a period (.) in consecutive positions.

System Action: Script Create terminates.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0450E Parameter <parm_name> dataset <value> is of invalid length.

Explanation: The named parameter is a dataset name and a dataset name must be between 1 and 44 characters long.

System Action: Script Create terminates.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0451E Parameter <parm_name> dataset <value> has invalid segment <segment_name>.

Explanation: The named parameter is a dataset name. A dataset name is made up of one or more “segments”, delimited by periods. Each segment must be 1 to 8 characters long. Also, each segment must start with an alphabetic character (A..Z,@,#,$). The rest of a segment can contain alphabetic and numeric characters, plus @,#,$,-,(.

System Action: Script Create terminates.

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0452E Parameter <parm_name> integer <value> has a non-numeric character.

Explanation: Integers must consist solely of digits.

System Action: Script Create terminates.

Page 196: Hiperstation Messages and Codes

5-8 Hiperstation Messages and Codes

User Response: Correct or remove the referenced SYSIN input line.

SCRTCP-0453E A repository set must be specified.

Explanation: A repository set, consisting of one or more Hiperstation for Mainframe Servers datasets, must be provided to the converter.

System Action: Script Create terminates.

User Response: Provide an appropriate repository value in the SYSIN control cards.

SCRTCP-0454E Only one asterisk is allowed in a repository name. <dataset_name>.

Explanation: A repository set specification can contain only a single asterisk and it must be the final character.

System Action: Script Create terminates.

User Response: Correct the appropriate SYSIN control card.

SCRTCP-0455E Fully expanded repository set specification <dataset_name> is > 44 characters long

Explanation: A dataset generated from a repository set specification can be a maximum of 44 characters long. When padded out for the asterisk wildcard, this dataset is too long.

System Action: Script Create terminates.

User Response: Correct the repository set specification in the appropriate SYSIN control card.

SCRTCP-0456E Asterisks and Question Marks cannot be mixed. <dataset_name>.

Explanation: A repository set specification can contain either a single asterisk or multiple (1..7), consecutive question marks as the final characters.

System Action: Script Create terminates.

User Response: Correct the repository set specification in the appropriate SYSIN control card.

SCRTCP-0457E Question Marks must be contiguous. <dataset_name>.

Explanation: A repository set specification can contain either a single asterisk or multiple (1..7), consecutive question marks as the final characters.

System Action: Script Create terminates.

User Response: Correct the repository set specification in the appropriate SYSIN control card.

SCRTCP-0458E Too many consecutive question marks. <dataset_name>.

Explanation: A repository set specification can contain either a single asterisk or multiple (1..7), consecutive question marks as the final characters.

System Action: Script Create terminates.

User Response: Correct the repository set specification in the appropriate SYSIN control card.

SCRTCP-0459E First: <value> must be less than Last: <value>.

Explanation: A repository set specification defines a range of wildcarded integer values, from First to Last. First must be lower than last to provide a valid range.

System Action: Script Create terminates.

User Response: Correct the TCPCSI1/2 and/or TCPCSO1/2 SYSIN control cards as appropriate.

SCRTCP-0460E First/Last: <first_val>/<last_val> too long to fit in wildcarded area <dataset_name>.

Explanation: The wildcarded area in the last segment is too short to contain either the FIRST or LAST value provided.

System Action: Script Create terminates.

User Response: Correct the appropriate SYSIN control cards.

Page 197: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-9

SCRTCP-0461E Repository message size so far (<current_msgsize>) is greater than maximum: <max_msg_size>.

Explanation: Script Create reads a message from the input repository set that is larger than the maximum message size, as defined by the greater of the 32K default and the SYSIN TCPCSMSG parameter. The size of the portion of the input message retrieved so far is <current_msgsize>. The total size of this input message may be larger.

System Action: Script Create terminates.

User Response: To increase the size of the message buffer, add or modify the SYSIN TCPCSMSG parameter to make it larger. TCPCSMSG is defined in units of 1K and must be specified in single quotes.

SCRTCP-462W Invalid RO 'ro' specified. Related criterion will be ignored.

Explanation: An invalid relational operator was detected on a protocol CONTENT filter record.

User Response: Correct the relational operator value in the SYSIN parameters or rebuild the Script Create job using the Hiperstation for Mainframe Servers panels.

SCRTCP-463E Invalid filter# specified: # (of #) for protocol filter# #.

Explanation: In the SYSIN parms, a protocol CONTENT filter was specified with a filter number greater than the filter count associated with the protocol filter.

User Response: In the SYSIN parms, correct the protocol filter count (FILTERS._CONTENT value) or delete all records associated with the flagged protocol CONTENT filter. Alternatively, rebuild the Script Create job using the Hiperstation for Mainframe Servers panels.

SCRTCP-464W Invalid filter action 'aaaa' specified. Related filter will be ignored.

Explanation: A filter action other than INCL or EXCL was specified on a protocol CONTENT filter record in the SYSIN parms.

User Response: In the SYSIN parms, change the filter action (FILTERS._ACTION) to INCL (include) or EXCL (exclude). Alternatively, rebuild the Script Create job using the Hiperstation for Mainframe Servers panels.

SCRTCP-0465I Expanded repository message buffer, new size is <new_size>.

Explanation: Archive Search read a message from the input repository set that was larger than the maximum message size as defined my &MAXMSG in ETRMGPAR. A new buffer was successfully allocated that was able to contain the complete message.

System Action: Archive Search continues processing.

User Response: None required. Optionally, to increase the size of the message buffer, add or modify the &MAXMSG value in ETRMGPAR.

SCRWMQSCRWMQ-0500I Hiperstation for WebSphere MQ Script Creation <version> <build>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0501I Executed with <product> Version <num> Release <num> Modification <num>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0502E Storage could not be allocated for <structure_name> structure.

Explanation: The storage required to create the named structure was not available.

System Action: Script Create terminates.

Page 198: Hiperstation Messages and Codes

5-10 Hiperstation Messages and Codes

User Response: Increase region size and rerun the script create job. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0503E Creation of the Global Hash Table failed.

Explanation: The C hcreate() function failed to define the global hash table.

System Action: Script Create terminates.

User Response: Increase region size and rerun the script create job. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0504I Input Parameters being read from DDname: <ddname>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0505E <ddname> file of input parameters could not be opened.

Explanation: Script Create could not open the file containing the input parameters.

System Action: Script Create terminates.

User Response: Verify that the parameter input dataset is properly defined as a fixed byte, 80 character record length file and is defined in the Script Create JCL correctly. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0506E Open of initial segment in repository set <dataset_name> failed.

Explanation: Script Create could not open the first or only dataset in the input repository set specification.

System Action: Script Create terminates.

User Response: Verify that the SYSIN MQSCSODN parameter was entered correctly and is a valid Hiperstation for WebSphere MQ repository. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0507I Return code = <retcode>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0508W No scripts were created.

Explanation: Warning message.

System Action: None.

User Response: Verify that both the input repository sets and the provided filter criteria were specified correctly.

Code Description

0 Scripts were created successfully.

4Something occurred that warrants further investigation. See earlier messages that were issued for details causing this return code. Scripts may or may not have been created as expected.

8

An error was encountered that must be corrected to have reliable scripts. See earlier messages that were issued for details causing this return code. Scripts will probably not have been created as expected. A return code of 8 usually indicates a problem that can be corrected by the user.

12

A severe error was encountered that must be corrected to have reliable scripts. See earlier messages that were issued for details causing this return code. Scripts will probably not have been created as expected. A return code of 12 usually indicates an unexpected problem that cannot be corrected by the user.

Page 199: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-11

SCRWMQ-0509W No CSV event summary was created.

Explanation: Informational message.

System Action: None.

User Response: Verify that both the input repository sets and the provided filter criteria were specified correctly.

SCRWMQ-0510I Created <count> PDSE members.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0511W No repository records matched filter criteria.

Explanation: Warning message.

System Action: None.

User Response: Verify that both the input repository sets and the provided filter criteria were specified correctly.

SCRWMQ-0512W The repository is empty.

Explanation: Warning message.

System Action: None.

User Response: Verify that the input repository sets were specified correctly.

SCRWMQ-0513E HFS file delete failed for dataset <dataset>. rc: <rc>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: Verify that the HTML Event Summary dataset parameters were specified correctly. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0514E Failed to create HTML or directory. Path: <path> prefix: <prefix> suffix: <suffix> replace: <replace_flag> rc: <rc>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: Verify that the HTML Event Summary dataset parameters were specified correctly. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0515W No events match the specified filters.

Explanation: Warning message.

System Action: None.

User Response: Verify that any filters specified were entered correctly.

SCRWMQ-0516E Global hash table add entry failed for object type: <id>, object: <id_str>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: Contact Compuware Customer Support.

SCRWMQ-0517E Unhandled event <event_no> in repository, record <rec_no>.

Explanation: Script Create encountered an MQ record type that is not recognized.

System Action: Script create terminates.

User Response: Verify the data captured in the input repository set. If the problem persists, contact Compuware Customer Support.

Page 200: Hiperstation Messages and Codes

5-12 Hiperstation Messages and Codes

SCRWMQ-0518E Routine <routine_name> could not locate connection summary block <id_str>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0519E Routine <routine_name> could not locate object summary block <id_str>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0520W MQ_CLOSE found in repository without corresponding MQ_OPEN.

Explanation: Warning message.

System Action: None.

User Response: Verify that the input repository set has captured all of the required MQ events.

SCRWMQ-0521W MQ_DISCONNECT found in repository without corresponding MQ_CONNECT.

Explanation: Warning message.

System Action: None.

User Response: Verify that the input repository set contains all of the required MQ events.

SCRWMQ-0522W Unable to determine queue name for <event_name>.

Explanation: Warning message.

System Action: None.

User Response: None.

SCRWMQ-0523I Connection Id('<id_num>') Object Id('<id_num>').

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0524E Routine <routine_name> could not locate connection block <id_str>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0525E Routine <routine_name> could not locate object block <id_str>.

Explanation: Internal failure.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0526W Data found in repository without corresponding <event_name>.

Explanation: Warning message.

System Action: None.

User Response: Verify that the input repository set contains all of the MQ events required.

SCRWMQ-0527E Invalid detail data processing selection <select_no>.

Explanation: Internal failure.

System Action: Script create terminates.

Page 201: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-13

User Response: Validate the script create detail processing SYSIN parameter MQSCCNTA, which should be in the range 1..3. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0528E Output repository segment <dataset_name> dynamic allocation failed.

Explanation: Script creation could not dynamically create the output repository dataset.

System Action: Script create terminates.

User Response: Validate that the SYSIN repository set allocation parameters are valid and meet local site standards. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0529E A valid repository dataset name must be specified.

Explanation: An unallocated dataset name must be provided, via the MQSCSODN SYSIN card, for use as the dynamically created subset repository set specification.

System Action: Script create terminates.

User Response: Validate the SYSIN subset repository parameter MQSCSODN. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0530E Output repository segment <segment_name> already exists.

Explanation: Script create attempted to create the named output repository set segment/dataset, but that dataset already exists.

System Action: Script create terminates rather than overwrite an existing dataset.

User Response: Specify a value for SYSIN subset repository parameter MQSCSODN that does not already exist.

SCRWMQ-0531E Dynalloc() failed. rc: <value>, error: <value>, info: <value>

Explanation: The dynamic allocation of the file failed. The rc (return code), error (error code) and info (information code) values can be looked up in the IBM z/OS MVS programming Authorized Services Assembler Guide manual.

System Action: Script create terminates.

User Response: Validate that the SYSIN subset repository parameter MQSCSODN specifies a dataset that does not exist. Verify that all of the other dataset allocation parameters are valid, obey local sit standards, and do not contradict each other. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0532E Repository message size so far (<current_msgsize>) is greater than maximum: <max_msg_size>.

Explanation: Script Create reads a message from the input repository set that is larger than the maximum message size, as defined by the greater of the 32K default and the SYSIN MQSCSMSG parameter. The size of the portion of the input message retrieved so far is <current_msgsize>. The total size of this input message may be larger.

System Action: Script create terminates.

User Response: To increase the size of the message buffer, add or modify the SYSIN MQSCSMSG parameter to make it larger. MQSCSMSG is defined in units of 1K with a default of 32.

SCRWMQ-0533E Invalid Repository record ignored, type (<num>, rec#(<num>)

Explanation: Script create discovered an input repository record with an unknown type. For script create purposes, this record is ignored.

System Action: Script create proceeds.

User Response: Note the events surrounding the message and contact Compuware Customer Support.

SCRWMQ-0534E Output repository set <repository set> is full.

Explanation: Script create has filled up the output repository set. Remaining input repository records eligible for output will not be written.

System Action: Script create terminates.

Page 202: Hiperstation Messages and Codes

5-14 Hiperstation Messages and Codes

User Response: Specify a larger output repository set, either by increasing the FIRST..LAST range, increasing the primary and/or secondary space values or by altering the space unit value.

SCRWMQ-0535E First write to output repository segment <repository set> failed, return code: <number>.

Explanation: The first fwrite() to an output repository segment failed with the noted return code.

System Action: Script create terminates.

User Response: Validate the subset/output repository set specification, particularly the dataset naming convention, to ensure that the correct names and dataset characteristics are used. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0536E Fwrite() to output subset repository <dataset_namet> failed.

Explanation: A write to an output repository dataset failed without being an end-of-file (EOF).

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0537I Log member <member> created in dataset <dataset>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0538E Log statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the log member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the log dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0539I Event report <name> created in dataset <dataset>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0540E Event <name> could not be written to dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the log member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the log dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0541E Cannot open for append to HFS file <path>.

Explanation: The fopen() function will not open the named HFS file for appending data.

System Action: Script create terminates.

User Response: Verify that the HTML Event Summary path parameters are specified correctly. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0542E Event control block is required for a non-synthesized XML <event>.

Explanation: Internal error.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

Page 203: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-15

SCRWMQ-0543E Routine <name> failed with return code: <rc>.

Explanation: Internal error - the named routine was invoked and returned the named error code.

System Action: Script create terminates.

User Response: If the problem persists, contact Compuware Customer Support.

SCRWMQ-0544I Unknown repmf2 value: <number>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0545W Invalid MQRPL FLOPTIONS key: <key_str> value: <hex_str>

Explanation: Unknown MQRPL FLOPTIONS key and value found in repository record.

System Action: Script create proceeds.

User Response: If the situation persists, contact Compuware Customer Support.

SCRWMQ-0546E Invalid <CB_name> encountered, writing as hexadecimal.

Explanation: The return code for the current MQ event/verb indicates that the named control block has an invalid structure. This control block will be generated, if requested, in the script and HTML event summary as raw hexadecimal data, without interpretation.

System Action: Script create terminates.

User Response: If the situation persists, contact Compuware Customer Support.

SCRWMQ-0547E Could not obtain a unique member name in dataset <dsname> after <number> tries.

Explanation: Script create could not obtain a member name in the target dataset for scripts, details or log after the noted number of attempts.

System Action: Script create terminates.

User Response: Examine the prefix and suffix values specified for the named dataset and alter them to create an unused namespace for script create to use. If the situation persists, contact Compuware Customer Support.

SCRWMQ-0548E Output <dataset_member> member could not be opened by fopen().

Explanation: The named dataset and member combination could not be opened.

System Action: Script create terminates.

User Response: Determine why members in the named dataset cannot be opened. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0549I Script member <member> created in dataset <dataset>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0550E Script statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the script member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the script dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0551I Combined detail member <member> created in dataset <dataset>.

Explanation: Informational message.

Page 204: Hiperstation Messages and Codes

5-16 Hiperstation Messages and Codes

System Action: None.

User Response: None.

SCRWMQ-0552E Combined detail statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the combined detail member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the combined detail dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0553I GET member <member> created in dataset <dataset>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0554E GET statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the GET member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the GET dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0555I PUT member <member> created in dataset <dataset>.

Explanation: Informational message.

System Action: None.

User Response: None.

SCRWMQ-0556E PUT statistics could not be written to member <member> in dataset <dataset>.

Explanation: The fclose and/or STOW macro failed to write out statistics to the PUT member in the named dataset.

System Action: Script create terminates.

User Response: Verify that the PUT dataset name is correct and is available for output. If the problem persists, contact Compuware Customer Support.

SCRWMQ-0557W Parameter name is missing from SYSIN input line <input_line>

Explanation: Script create cannot locate a valid SYSIN parameter name from the data in the displayed line of SYSIN input.

System Action: Script create ignores this SYSIN line.

User Response: Correct or remove the referenced SYSIN input card.

SCRWMQ-0558E Unknown SYSIN parameter name <name> located.

Explanation: Script create extracts an undefined SYSIN input parameter name.

System Action: Script create terminates.

User Response: Correct or remove the referenced SYSIN input card.

SCRWMQ-0559W Error in parsing for filter <filter_name>. Filter will be ignored.

Explanation: Script create has discovered an inconsistency or error in the named filter. This filter will not be used in MQ event filtering.

System Action: Script create proceeds.

User Response: Correct or remove the named filter from the SYIN input.

Page 205: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-17

SCRWMQ-0560I Maximum content record size is <number>.

Explanation: Informational message.

System Action: None.

User Response: Can be used to assist user in setting the MQSCSMSG SYSIN parameter.

SCRWMQ-0561W Unable to determine queue manager for <event_name>.

Explanation: Warning message.

System Action: None.

User Response: None.

SCRWMQ-0562I Subset repository successfully created.

Explanation: Informational message.

System Action: None.

User Response: None.

SPBTCHSPBTCH010 ERROR IN READING HIPERIN DD STATEMENT

Explanation: During batch processing, the script processor attempted an EXECIO DISKR operation to read the data pointed to by the HIPERIN DD statement. The HIPERIN DD contains INFILE, OUTFILE, ISCRIPT, and OSCRIPT statements that identify the scripts to the batch processor. Additional messages may appear describing why the EXECIO failed. The EXECIO return codes are explained below:

SPBTCH020 INFILE/OUTFILE STATEMENT MISSING OR INCORRECT

Explanation: During batch processing, the INFILE and/or OUTFILE statement was not found or was invalid.

SPBTCH030 INVALID FORMAT ON INFILE STATEMENT

Explanation: During batch processing, the INFILE statement was being analyzed and was found to be invalid.

SPBTCH040 INVALID FORMAT ON OUTFILE STATEMENT

Explanation: During batch processing, the OUTFILE statement was being analyzed and was found to be invalid.

SPBTCH050 ISCRIPT STATEMENT MISSING

Explanation: During batch processing, the ISCRIPT statement was being analyzed and was not found.

SPBTCH060 INVALID FORMAT ON ISCRIPT STATEMENT

Explanation: During batch processing, the ISCRIPT statement was being analyzed and was found to be incorrect.

RC Explanation

0 Normal completion of requested operation.

1 Data was truncated during DISKW operation.

2End-of-file reached before the set number of lines were read during a DISKR or DISKRU operation. This does not occur if * (asterisk) is used for number of lines because the remainder of the file is always read.

4 During a DISKR or DISKRU operation, an empty dataset was found in a concatenation of datasets. The file was not successfully opened and no data was returned.

20 Severe error. EXECIO completed unsuccessfully and a message is issued.

Page 206: Hiperstation Messages and Codes

5-18 Hiperstation Messages and Codes

SPBTCH070 INVALID FORMAT ON OSCRIPT STATEMENT

Explanation: During batch processing, the OSCRIPT statement was being analyzed and was found to be incorrect.

SPBTCH080 OSCRIPT STATEMENT MISSING

Explanation: During batch processing, the OSCRIPT statement was being analyzed and was not found.

SPBTCH090 ERROR IN ALLOCATION OF INFILE DATASET

Explanation: During batch processing, an attempt was made to allocate the input script dataset, but an error was encountered. Additional messages may be included to detail the cause of the failed allocation.

SPBTCH100 ERROR IN ALLOCATION OF OUTFILE DATASET

Explanation: During batch processing, an attempt was made to allocate the output script dataset, but an error was encountered. Additional messages may be included to detail the cause of the failed allocation.

SPCHGSPCHG001 SELECT AN OPTION OR END - "GO" TO INITIATE PROCESSING, THE END KEY TO EXIT, OR ENTER TO UPDATE REQUESTS

Explanation: You have not selected an option.

User Response: Use “GO”, the END key, or the ENTER key.

SPCHG002 PLEASE ENTER "F" or "B" - ENTER AN "F" TO PROCESS UNDER TSO, OR "B" TO CREATE A BATCH JOB

Explanation: You have not specified a command.

User Response: Use either “F” or “B”.

SPCHG004 INVALID DATASET NAME

Explanation: The dataset name you specified is invalid.

User Response: Make sure the dataset exists and is spelled correctly.

SPCHG007 DATASET NOT FOUND

Explanation: The dataset you specified is invalid.

User Response: Make sure the dataset exists and is spelled correctly.

SPCHG010 MEMBER NOT FOUND - THE REQUESTED MEMBER IS NOT A MEMBER OF THE PDS

Explanation: The member you specified was not found.

User Response: Check the spelling and make sure the member exists.

SPCHG011 MEMBER ALREADY EXISTS - THE HIGHLIGHTED SCRIPT EXISTS AND "do not replace" IS SELECTED

Explanation: The member name you specified already exists.

User Response: Use another name, or select replace member.

SPCHG025 ENTER "B","U","D" - "B"rowse, "U"pdate and "D"elete ARE THE VALID LINE COMMANDS

Explanation: The command you specified is invalid.

User Response: Use “B”, “U”, or “D”.

SPCHG026 MEMBER NAME IS REQUIRED - ENTER A MEMBER NAME IN THE HIGHLIGHTED FIELD

Explanation: You did not specify a member name.

Page 207: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-19

User Response: Specify a member name in the highlighted field.

SPCHG028 INVALID ROW NUMBER - THE ROW NUMBER MUST BE BETWEEN 1 AND 43

Explanation: The row number you specified is invalid.

User Response: Use a number from 1 to 43.

SPCHG029 INVALID COLUMN NUMBER - THE COLUMN NUMBER MUST BE BETWEEN 1 AND 133

Explanation: The column number you specified is invalid.

User Response: Use a number from 1 to 133.

SPCHG032 LIBRARY NOT FOUND - THE SELECTED SCRIPT PROCESSOR LIBRARY CANNOT BE FOUND

Explanation: The library you specified cannot be found.

User Response: Check the spelling, and make sure the library exists.

SPCHG033 PDS IS REQUIRED - THE SELECTED SCRIPT PROCESSOR CONTROL DS MUST BE A PDS

Explanation: The dataset you specified is not a PDS.

User Response: Use a PDS for your control dataset.

SPCHG036 MEMBER NOT ALLOWED - SPECIFY A MEMBER NAME ONLY WHEN USING A PDS AS THE CONTROL FILE

Explanation: A member name is not required here.

User Response: Use a sequential dataset name.

SPCHG037 DIRECTORY BLOCKS REQUIRED - WHEN ALLOCATING A SCRIPT DATASET THE DIRECTORY BLOCKS ENTRY IS REQUIRED

Explanation: You have not specified a directory blocks entry.

User Response: Enter a directory blocks value.

SPCHG043 INVALID SELECTION - PLEASE SELECT ONE OF THE LISTED VALUES BELOW

Explanation: The selection you specified is invalid.

User Response: Select one of the values listed below.

SPCHG045 INVALID COMMAND - COMMAND ENTERED IS NOT VALID ON THIS PANEL

Explanation: The command you entered is not valid.

User Response: Make sure the spelling was correct, or use another command.

SPCNTLSPCNTL010 ERROR IN READING CNTLIN DD STATEMENT

Explanation: An error was encountered during an EXECIO DISKR operation to read the control file. EXECIO return codes are listed under message SPBTCH010. Additional messages may be included to detail the cause of the failed EXECIO.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL020 UNRECOGNIZED OR MISSING LABEL IN CONTROL FILE

Explanation: As the script processor read the contents of the control file, it expected to find an entry label such as <DATAREP>, <DATEREC>, <LISTPROC>, or <SYNCHRONIZE>, but a label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 208: Hiperstation Messages and Codes

5-20 Hiperstation Messages and Codes

SPCNTL030 EXPECTED ADESCR PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the description record. However, the <ADESCR> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL040 EXPECTED ASCRNIDF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the screen ID record. However, the <ASCRNIDF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL050 EXPECTED ASCRROWF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the ID row record. However, the <ASCRROWF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL060 ASCRROWF PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the row number of the screen ID. The row was found to be neither numeric nor asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL070 EXPECTED ASCRCOLF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the screen ID column record. However, the <ASCRCOLF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL080 ASCRCOLF PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the column number of the screen ID. It was found to be neither numeric nor asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL090 EXPECTED AROWF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the row number of the system generated field. However, the <AROWF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL100 AROWF PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the row number of the system generated field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 209: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-21

SPCNTL110 EXPECTED ACOLUMNF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the column number of the system generated field. However, the <ACOLUMNF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL120 ACOLUMNF PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the column number of the system generated field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL130 EXPECTED ALENGTHF PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the length of the system generated field. However, the <ALENGTHF> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL140 ALENGTHF PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the length of the system generated field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL150 EXPECTED AMATCH PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the exact match record. However, the <AMATCH> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL160 AMATCH PARAMETER NOT Y OR N

Explanation: As the script processor read the contents of a data replacement entry in the control file, it analyzed the exact match record. The value was not Y or N.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL170 EXPECTED </DATAREP> LABEL NOT FOUND

Explanation: As the script processor read the contents of a data replacement entry in the control file, it expected to find the ending label for the entry. However, the </DATAREP> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL180 EXPECTED EDESCR PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the description record. However, the <EDESCR> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL190 EXPECTED ESCRNID PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the screen ID record. However, the <ESCRNID> label was not found.

Page 210: Hiperstation Messages and Codes

5-22 Hiperstation Messages and Codes

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL200 EXPECTED ESCRROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the screen ID row record. However, the <ESCRROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL210 ESCRROW PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the screen ID row number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL220 EXPECTED ESCRCOL PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the screen ID column record. However, the <ESCRCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL230 ESCRCOL PARAMETER NOT NUMERIC OR ***

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the screen ID column number. The value was not numeric or asterisks (***), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL240 EXPECTED EFIELD PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the input field number record. However, the <ESCRCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL250 EFIELD PARAMETER NOT NUMERIC OR ***

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the input field number. The value was not numeric or asterisks (***).

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL260 EXPECTED EDSEP PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the date separator record. However, the <EDSEP> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL270 EDSEP CAN ONLY BE 1 CHARACTER LONG

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the date separator. The value was longer than 1 character.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 211: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-23

SPCNTL280 EXPECTED EFORMAT PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the input date format record. However, the <EFORMAT> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL285 EXPECTED EOFORMAT PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the output date format record. However, the <EFORMAT> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL290 EFORMAT PARAMETER NOT 1-14

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the input date format. The value was not valid. Valid values are 1 through 14.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL295 EOFORMAT PARAMETER NOT 1-14

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the output date format. The value was not valid. Valid values are 1 through 14.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL300 EXPECTED EWKDAY PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the weekday only record. However, the <EWKDAY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL310 EWKDAY PARAMETER NOT Y OR N

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it analyzed the weekday only field. The value was not Y or N.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL320 EXPECTED </DATEREC> LABEL NOT FOUND

Explanation: As the script processor read the contents of a date recalculation entry in the control file, it expected to find the ending label for the entry. However, the </DATEREC> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL322 EXPECTED EODTROW PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it expected to find the output date row record. However, the <EODTROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 212: Hiperstation Messages and Codes

5-24 Hiperstation Messages and Codes

SPCNTL324 EODTROW NOT NUMERIC OR **

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it analyzed the output date row number. The value was not numeric or asterisk (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL326 EXPECTED EODTCOL PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it expected to find the output date column record. However, the <EODTCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL328 EODTCOL NOT NUMERIC OR ***

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it analyzed the output date column number. The value was not numeric or asterisk (***), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL329 EXPECTED EOVRLAY PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it expected to find the overlay output area record. However, the <EOVRLAY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL329A EOVRLAY PARAMETER NOT Y OR N

Explanation: As the script processor reads the contents of a date recalculation entry in the control file, it analyzed the overlay output area field. The value was not Y or N, which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL330 EXPECTED SDESCR PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the description record. However, the <SDESCR> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL330A EXPECTED MFDESCR PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the description record. However, the <MFDESCR> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL340 EXPECTED SSCRNID PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the screen ID record. However, the <SSCRNID> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 213: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-25

SPCNTL340A EXPECTED MFSCRNID PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the screen ID record. However, the <MFSCRNID> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL350 EXPECTED SSCRROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the screen ID row record. However, the <SSCRROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL350A EXPECTED MFSCRROW PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the screen ID row record. However, the <MFSCRROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL360 SSCRROW PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the screen ID row number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL360A MFSCRROW PARAMETER NOT NUMERIC OR **

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the screen ID record number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370 EXPECTED SSCRCOL PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the screen ID column record. However, the <SSCRCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370A EXPECTED MFSCRCOL PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the screen ID column record. However, the <MFSCRCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370B EXPECTED MONTHI PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the input month field record. However, the <MONTHI> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 214: Hiperstation Messages and Codes

5-26 Hiperstation Messages and Codes

SPCNTL370C EXPECTED DAYI PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the day input field record. However, the <DAYI> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370D EXPECTED YEARI PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the year input field record. However, the <YEARI> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370E EXPECTED MKWKDAY PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the weekday only record. However, <MKWKDAY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370F EXPECTED MONTHO PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the output month field. However, the <MONTHO> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370G Expected DAYO parameter not found

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the output day field. However, the <DAYO> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370H EXPECTED </MFDATE> LABEL NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the ending label for the entry. However, the </MFDATE> was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL370I EXPECTED YEARO PARAMETER NOT FOUND

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it expected to find the output year field. However, the <YEARO> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380 SSCRCOL PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the screen ID column number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 215: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-27

SPCNTL380A MFSCRCOL PARAMETER NOT NUMERIC OR ***

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the screen ID column number. The value was not numeric or asterisks (***), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380B MONTHI PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the input month field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380D DAYI PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the input day field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380F YEARI PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the input year field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380H PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the output month field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380I PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the output day field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL380J YEARO PARAMETER NOT NUMERIC

Explanation: As the script processor reads the contents of a multi-date recalculation entry in the control file, it analyzed the output year field. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL390 EXPECTED SMSGTXT PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the message text record. However, the <SMSGTXT> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL400 EXPECTED SMSGROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the message row record. However, the <SMSGROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 216: Hiperstation Messages and Codes

5-28 Hiperstation Messages and Codes

SPCNTL410 SMSGROW PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the message row number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL420 EXPECTED SMSGCOL PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the message column record. However, the <SMSGCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL430 SMSGCOL PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the message column number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL440 EXPECTED SACTION PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the action to take record. However, the <SACTION> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL450 EXPECTED SDLYMIN PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the delay minute record. However, the <SDLYMIN> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL460 SDLYMIN PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the delay minute number. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL470 EXPECTED SDLYSEC PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the delay second record. However, the <SDLYSEC> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL480 SDLYSEC PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the delay second number. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL490 EXPECTED SRPTMAX PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the max repeat record. However, the <SRPTMAX> label was not found.

Page 217: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-29

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL500 SRPTMAX PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a synchronization entry in the control file, it analyzed the max repeat number. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL510 EXPECTED </SYNCHRONIZE> LABEL NOT FOUND

Explanation: As the script processor read the contents of a synchronization entry in the control file, it expected to find the ending label for the entry. However, the </SYNCHRONIZE> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL530 EXPECTED LDESCR PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the description record. However, the <LDESCR> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL540 EXPECTED LSCRNID PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the screen ID record. However, the <LSCRNID> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL550 EXPECTED LSCRROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the screen ID row record. However, the <LSCRROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL560 LSCRROW PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the screen ID row number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL570 EXPECTED LSCRCOL PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the screen ID column record. However, the <LSCRCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL580 LSCRCOL PARAMETER NOT NUMERIC OR **

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the screen ID column number. The value was not numeric or asterisks (**), which are the only valid values.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 218: Hiperstation Messages and Codes

5-30 Hiperstation Messages and Codes

SPCNTL590 EXPECTED LTOPROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the list top row number. However, the <LTOPROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL600 LTOPROW PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the list top row number. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL610 EXPECTED LBOTROW PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the list bottom row number. However, the <LBOTROW> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL620 LBOTROW PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the list bottom row number. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL630 EXPECTED LUPKEY PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the up scroll key record. However, the <LUPKEY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL640 EXPECTED LDOWNKEY PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the down scroll key record. However, the <LDOWNKEY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL650 EXPECTED LKEYCOL PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the key column record. However, the <LKEYCOL> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL660 LKEYCOL PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the key column record. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL670 EXPECTED LKEYLEN PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the key length record. However, the <LKEYLEN> label was not found.

Page 219: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-31

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL680 LKEYLEN PARAMETER NOT NUMERIC

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the key length record. The value was not numeric.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL690 EXPECTED LEND PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the end of list ID record. However, the <LEND> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL700 LEND PARAMETER NOT 1-4

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the end of list ID record. The value was not 1-4.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL710 EXPECTED LENDTEXT PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the end of list row text record. However, the <LENDTEXT> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL720 LENDTEXT PARAMETER VALUE REQUIRED

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the end of list row text. The value was empty. The end of list row text is required when the end of list ID field is set to option 3.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL730 EXPECTED LTYPE PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the list type record. However, the <LTYPE> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL740 LTYPE PARAMETER MUST BE CURSOR OR LINECMD

Explanation: As the script processor read the contents of a list processing entry in the control file, it analyzed the list type and found an invalid value. The list type must be either CURSOR or LINECMD.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCNTL750 EXPECTED LSELKEY PARAMETER NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the list selection PF-key record. However, the <LSELKEY> label was not found.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

Page 220: Hiperstation Messages and Codes

5-32 Hiperstation Messages and Codes

SPCNTL760 EXPECTED </LISTPROC> LABEL NOT FOUND

Explanation: As the script processor read the contents of a list processing entry in the control file, it expected to find the record label which marks the end of the list processing entry.

User Response: The listed control file was corrupted. Delete and re-create the entry, then re-run the script processor.

SPCPWSPCPW001 ENTRIES MUST MATCH - NEW PASSWORD AND VERIFY NEW PASSWORD ENTRIES MUST MATCH

Explanation: The New password and Verify password entries do not match.

User Response: Make sure both entries are spelled the same.

SPCPW002 PROCESSING OPTION IS REQUIRED - PLEASE ENTER "F" FOR FOREGROUND OR "B" FOR BACKGROUND PROCESSING

Explanation: You have omitted the processing option.

User Response: Use either “F” or “B”.

SPCPW005 SCRIPT NOT FOUND

Explanation: The script you specified was not found.

User Response: Make sure the script name is spelled correctly and that it exists.

SPCPW006 PLEASE SELECT A SCRIPT(S) - PLEASE ENTER AN "S" OR "/" TO IDENTIFY THE SCRIPTS TO PROCESS

Explanation: You have not selected a script to process.

User Response: Use an “S” or “/” to select a script.

SPCPW008 INVALID VALUE - VALID VALUES FOR THIS FIELD ARE (blank), "/", AND "S"

Explanation: The value you specified is invalid.

User Response: Use either “S”, “/”, or a blank.

SPGMFSPGMF001 DIRECTORY BLOCKS REQUIRED - WHEN ALLOCATING A REXX DATASET, THE DIRECTORY BLOCKS ENTRY IS REQUIRED

Explanation: You have omitted the directory blocks value.

User Response: Enter a value for directory blocks.

SPGMF002 THE VALUE MUST BE EQ/NE - THE VALUE MUST BE EITHER EQ OR NE

Explanation: The value you specified is invalid.

User Response: Use either EQ or NE.

SPGMF003 VALUE MUST BE AND/OR - THE VALUE MUST BE EITHER AND OR OR

Explanation: The value you specified is invalid.

User Response: Use either AND or OR.

SPGMF004 INVALID VALUE - REPLACE SHOULD BE Y OR N

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

Page 221: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-33

SPGMF005 INVALID CASE SENSITIVE - THE VALUE OF CASE SENSITIVE SHOULD BE Y OR N

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

SPGMF006 INVALID ATTR SENSITIVE - THE VALUE OF ATTR SENSITIVE SHOULD BE Y OR N

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

SPGMF007 VALUE MUST BE NUMERIC. - THE ROW, COLUMN, INPUT FIELD NUMBER OR OFFSET SHOULD BE NUMERIC IF SPECIFIED

Explanation: The value you specified is invalid.

User Response: Use a numeric value.

SPGMF008 ROW, COL NEEDED. - THE VALUE FOR ROW COL MUST BE SPECIFIED

Explanation: You have omitted a row/col value.

User Response: Enter a value for the row and column.

SPGMF009 INPUT FIELD # NEEDED. - THE INPUT FIELD NUMBER MUST BE SPECIFIED

Explanation: You have omitted the input field number.

User Response: Enter a value for the input field number.

SPGMF016 REXX DATASET IS NOT PDS - THE SPECIFIED REXX DATASET IS NOT A PDS

Explanation: The dataset you specified is not a PDS.

User Response: Specify a PDS with a member name instead.

SPGMF017 REXX DATASET NOT FOUND - THE SPECIFIED REXX DATASET DOES NOT EXIST

Explanation: The dataset you specified could not be found.

User Response: Make sure the dataset exists and is spelled correctly.

SPGMF020 INVALID MESSAGE NAME - MESSAGE NAME MUST BE A VALID PDS MEMBER NAME

Explanation: The message name you specified is invalid.

User Response: Make sure you are using a valid PDS member name.

SPGMF021 INVALID REXX DATASET - REXX DATASET MUST BE A VALID MVS PDS NAME

Explanation: The dataset name you specified is invalid.

User Response: Make sure the dataset name is a valid MVS PDS name.

SPGMF026 INVALID START CURSOR ROW - CURSOR MUST BE NUMERIC IF SPECIFIED

Explanation: The Start Cursor Row value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF027 INVALID START CURSOR COL - CURSOR MUST BE NUMERIC IF SPECIFIED

Explanation: The Start Cursor Column value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF028 INVALID END CURSOR ROW - CURSOR MUST BE NUMERIC IF SPECIFIED

Explanation: The End Cursor Row value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF029 INVALID END CURSOR COL - CURSOR MUST BE NUMERIC IF SPECIFIED

Explanation: The End Cursor Column value you specified is invalid.

User Response: Retry using a numeric value.

Page 222: Hiperstation Messages and Codes

5-34 Hiperstation Messages and Codes

SPGMF030 INVALID OFFSET - IF OFFSET SPECIFIED, IT MUST BE NUMERIC

Explanation: The Offset value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF031 INVALID OFFSET - IF OFFSET SPECIFIED, IT MUST BE NUMERIC

Explanation: The Offset value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF032 INVALID OFFSET - IF OFFSET SPECIFIED, IT MUST BE NUMERIC

Explanation: The Offset value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF033 INVALID OFFSET - IF OFFSET SPECIFIED, IT MUST BE NUMERIC

Explanation: The Offset value you specified is invalid.

User Response: Retry using a numeric value.

SPGMF034 THE REPORT FILE ERROR - THE REPORT FILE SPECIFIED IS A PDS AND THE MEMBER NAME DOES NOT EXIST

Explanation: The member name of the PDS you specified was not found.

User Response: Make sure the member exists and is spelled correctly.

SPGMF035 THE REPORT NOT FOUND - SPECIFIED DATASET DOES NOT EXIST

Explanation: The dataset you specified was not found.

User Response: Make sure the dataset exists and is spelled correctly.

SPGMF036 INCORRECT VALUE. - VALUE MUST BE PREVIOUS, CURRENT OR NEXT

Explanation: The value you specified is incorrect.

User Response: Use either PREVIOUS, CURRENT, or NEXT.

SPGMF037 VALUE MUST BE EQ - VALUE MUST BE EQ IF INPUT KEY OR CURSOR SPECIFIED

Explanation: The value you specified is invalid.

User Response: If you specify the Input Key or Cursor, then change your value to EQ.

SPGMF042 INVALID VALUE - VALID VALUE IS EITHER INCLUDE OR EXCLUDE

Explanation: The value you specified is invalid.

User Response: Use either INCLUDE or EXCLUDE.

SPGMF044 INVALID VALUE - VALID VALUE IS EITHER YES OR NO

Explanation: The value you specified is invalid.

User Response: Use either YES or NO.

SPGMF045 FILTER DATASET ERROR

Explanation: There was an error in the filter dataset.

User Response: Correct the error and rerun.

SPGMF046 DATASET IS NOT PDS

Explanation: The specified dataset is not a PDS.

User Response: Specify a different dataset that is a PDS.

SPGMF047 DATASET NOT FOUND

Explanation: The specified dataset was not found or does not exist.

User Response: Specify a dataset that exists.

Page 223: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-35

SPHPRSPHPR010 BEGINNING DATA REPLACEMENT PROCESSING

Explanation: Informational message. No user action necessary. The script processor has begun the data replacement work for the script being processed.

SPHPR020 TOTAL DATA REPLACEMENTS MADE: nn

Explanation: Informational message. No user action necessary. Shows the number of input fields that were replaced with REXX variables in the script being processed.

SPHPR030 DATA REPLACEMENT PROCESSING COMPLETE

Explanation: Informational message. No user action necessary.The data replacement work is finished for the script being processed.

SPHPR040 BEGINNING DATE RECALCULATION PROCESSING

Explanation: Informational message. No user action necessary. The script processor has begun the date recalculation work for the script being processed.

SPHPR050 TOTAL DATES RECALCULATED: nn

Explanation: Informational message. No user action necessary. Shows the number of input fields that were replaced with REXX variables in the script being processed.

SPHPR060 DATE RECALCULATION PROCESSING COMPLETE

Explanation: Informational message. No user action necessary. The date recalculation work is finished for the script being processed.

SPHPR070 BEGINNING SYNCHRONIZATION PROCESSING

Explanation: Informational message. No user action necessary. The script processor has begun the synchronization work for the script being processed.

SPHPR080 SYNCHRONIZATION PROCESSING COMPLETE

Explanation: Informational message. No user action necessary. The synchronization work is finished for the script being processed.

SPHPR090 READING INPUT SCRIPT

Explanation: Informational message. No user action necessary. The script processor is now reading in the current input script.

SPHPR100 INPUT SCRIPT READ COMPLETE

Explanation: Informational message. No user action necessary.The script processor has finished reading the current input script.

SPHPR110 SCREEN ID ‘????’ FOUND, BUT SYSTEM FIELD HAS NO VALUE

Explanation: Warning message. The script processor was looking for a system generated field for data replacement. It found the screen where the field should be, but the field was empty or was 0. The script processor will skip this field for use in data replacement and continue.

SPHPR120 DATE FIELD FOUND, BUT IT WAS NOT A DATE

Explanation: Warning message. The script processor was told that a particular input field number on a specific screen was a date to be recalculated. The field was found, but it was not a date. The script processor will skip this field for date recalculation and continue.

SPHPR130 DATE FIELD FOUND, BUT IT DID NOT MATCH DATE FORMAT

Explanation: Warning message. The script processor was told that a particular input field number on a specific screen was a date to be recalculated. The field was found, but the format did not match the date format listed in the control file entry. The script processor will skip this field for date recalculation and continue.

Page 224: Hiperstation Messages and Codes

5-36 Hiperstation Messages and Codes

SPHPR140 WRITING OUTPUT SCRIPT

Explanation: Informational message. No user action necessary.The script processor is creating the current output script.

SPHPR150 OUTPUT SCRIPT WRITE COMPLETE

Explanation: Informational message. No user action necessary.The script processor finished creating the current output script.

SPHPR160 SCRIPT PROCESSING FINISHED

Explanation: Informational message. No user action necessary. The script processor completed processing the input script.

SPHPR170 ERROR IN READING SCRPTIN DD FILE

Explanation: An error was encountered during an EXECIO DISKR operation to read the input script. EXECIO return codes are listed under message SPBTCH010. Additional messages may be included to detail the cause of the failed EXECIO.

SPHPR172 <INPUT> SECTION NOT FOUND IN INPUT SCRIPT<OUTPUT> SECTION NOT FOUND IN INPUT SCRIPT

Explanation: The input script did not contain any <INPUT> script statements. The input script is probably not a Hiperstation script.

User Response: Check your script to ensure that it is a Hiperstation script.

SPHPR180 SCRIPT CREATION DATE NOT FOUND IN SCRIPT HEADER

Explanation: An error was encountered during date recalculation processing for the current input script. The script processor was attempting to locate the date that the input script was recorded. It looks for this information in the script header. This message is generated if that date is not found.

SPHPR190 ERROR IN WRITING OUT TO SCRPTOUT DD FILE

Explanation: An error was encountered during an EXECIO DISKW operation to write the output script. EXECIO return codes are listed under message SPBTCH010. Additional messages may be included to detail the cause of the failed EXECIO.

SPHPR200 TOTAL DATES CHANGED: nnn

Explanation: Informational message. No user action necessary. Shows the number of date input fields that were changed from a two-digit to four-digit year.

SPHPR210 YEAR NOT 2 DIGITS

Explanation: Warning message. The date change script processor found a date input field that was not two digits. The date field is set in the message text. The date field shown will be skipped and not changed.

SPHPR220 YEAR IS 19 OR 20

Explanation: Warning message. The date change script processor found a date input field had a year equal to 19 or 20. The script processor assumes this is not a valid year because it is probably a century value. The date field is displayed in the message text. This could happen if the date field does not have a date separator and the year is a actually a four-digit year. The date change script processor changes two-digit year date fields to four-digit year date fields. The date listed is skipped and not changed.

SPHPR230 BEGINNING DATE CHANGE PROCESSING

Explanation: Informational message. No user action necessary. The script processor has begun date change processing.

SPHPR240 BEGINNING DATE FIND PROCESSING

Explanation: Informational message. No user action necessary. The script processor has begun date find processing.

Page 225: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-37

SPHPR250 ERROR IN ALLOCATING INPUT SCRIPT FILE

Explanation: The script processor attempted to open the input script file. The script in error is displayed with the message text.

SPHPR260 ERROR IN WRITING TO RPTOUT DD FILE

Explanation: The script processor attempted to write data to the date find report file. The error occurred during an EXECIO DISKW operation. More messages may accompany this one to explain the EXECIO failure. EXECIO return codes are listed under message SPBTCH010.

SPHPR270 INVALID DATE FORMAT

Explanation: The date find script processor was passed an invalid date format. Valid formats are 1-10.

User Response: Enter a valid format and rerun.

SPHPR280 BEGINNING CURSOR POSITION PROCESSING

Explanation: Informational message. No user action necessary. The input script is being processed. The input-field position numbers are being converted to row-column format.

SPHPR290E INVALID <Inn> FIELD NUMBER IN INPUT SCRIPT RECORD xxx

Explanation: Record number xxx in the input script has an input-field position number that is invalid. The position number is either:

• Too short: <I>• Too long: <I00000001>• Not within the preceding output screen: <I9999>

SPHPR340 BEGINNING LIST PROCESSING EXECUTION

Explanation: Informational message. No user action necessary. The REXX script processor has begun working on a list processing entry.

SPHPR350 TOTAL LIST SCREENS HANDLED:

Explanation: Informational message. No user action necessary. Shows the number of list screens in the script which required list processing REXX.

SPHPR360 LIST PROCESSING EXECUTION COMPLETE

Explanation: Informational message. No user action necessary. Indicates that the REXX script processor has finished writing list processing routines into the script.

SPHPR370 <INPUT> nnnnnnn SKIPPED FOR PROCESSING

Explanation: Warning message. The input field reformat script processor was attempting to reformat an <INPUT> message, but it could not because an <OUTPUT> message was not located prior to it in the script being processed.

SPHPR380 <OUTPUT> nnnnnnn HAS NO MATCHING </OUTPUT>

Explanation: Warning message. The input field reformat script processor was attempting to read through an <OUTPUT> message to gather input field locations, but a </OUTPUT> was not found. The <INPUT> following the <OUTPUT> that had the error will not be reformatted.

User Response: Correct the script so that each <OUTPUT> record type has a a corresponding </OUTPUT>, then rerun the script processor.

SPHPR390 TOTAL INPUT FIELDS CHANGED: nnn

Explanation: Informational message. No user action necessary. Shows the number of input fields in the script that were reformatted by the input field reformat script processor.

Page 226: Hiperstation Messages and Codes

5-38 Hiperstation Messages and Codes

SPMSGSPMSG002 OUTPUT SCRIPT EXISTS - EITHER CHANGE THE MEMBER NAME, OR SPECIFY REPLACE = Y

Explanation: The output script you specified already exists.

User Response: Either specify a new member name, or specify REPLACE=Y.

SPMSG003 INVALID COMMAND - VALID LINE COMMANDS ARE U AND D

Explanation: The command you specified is invalid.

User Response: Use either U or D for a line command.

SPMSG008 INVALID FORMAT - THE FIELD FORMAT MUST BE 1 OR 2

Explanation: The value you specified is invalid.

User Response: Use either a 1 or 2 for field format.

SPMSG010 INVALID MONTH - THE MONTH WHICH WAS ENTERED IS NOT VALID

Explanation: The month value you entered is invalid.

User Response: Use a value from 1 to 12.

SPMSG011 INVALID DAY - THE DAY MUST BE BETWEEN 1 AND 31

Explanation: The day value you entered is invalid.

User Response: Use a value from 1 to 31.

SPMSG014 ENTRY REQUIRED - PLEASE SUPPLY A DAY INPUT NUMBER OR A YEAR INPUT NUMBER

Explanation: An entry is still required on this screen.

User Response: Specify a day or year input number.

SPMSG015 ENTRY NOT ALLOWED - THE ENTRY IS VALID ONLY WHEN AN INPUT NUMBER FIELD IS SUPPLIED

Explanation: The entry you specified is not allowed at this time.

User Response: Use this entry only when an input number field is supplied.

SPMSG016 ENTRY REQUIRED - THE MONTH INPUT INFORMATION IS REQUIRED

Explanation: An entry is still required on this screen.

User Response: Specify a month input value.

SPMSG018 FIELD REQUIRED - THE LENGTH (FOR) FIELD IS REQUIRED WHEN THE POSITION (AT) FIELD IS > 1

Explanation: The LENGTH (FOR) field needs a value when the POSITION (AT) field > 1.

User Response: Specify a value for the LENGTH (FOR) field.

SPMSG020 ENTRY REQUIRED - PLEASE ENTER A VALID INPUT NUMBER FOR THE YEAR

Explanation: An entry is still required on this screen.

User Response: Specify a valid input number for the year.

SPMSG109 INPUT SCRIPT MISSING - PLEASE ENTER THE MISSING INPUT SCRIPT NAME

Explanation: The input script name has not been specified.

User Response: Specify an input script name.

SPMSG200 SCRIPT FIELD MISSING - PLEASE ENTER THE MISSING SCRIPT NAME

Explanation: The script name has not been specified.

User Response: Specify a script name.

Page 227: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-39

SPMSG204 MUST BE ** OR NUM - FIELD MUST BE NUMERIC OR **

Explanation: The field needs to be either numeric or **.

User Response: Specify either a numeric value or **.

SPMSG205 MUST BE ** - ROW AND COLUMN FIELDS MUST MATCH IF ** IS SPECIFIED FOR ONE

Explanation: The row and column fields must match if one of them is **.

User Response: Specify ** for both row and column.

SPMSG206 MUST BE ** - IF DATE SCREEN ID IS *, ID LOCATION ROW & COL MUST BE **

Explanation: Row and column fields must both be ** if date screen id is *.

User Response: Specify ** for both row and column.

SPMSG208 INVALID WILDCARD - WILDCARDING IS NOT ALLOWED FOR THIS FIELD

Explanation: You cannot specify a wildcard for this field.

User Response: Remove the wildcard and try again.

SPMSG209 ENTER OPTION - ENTER ONE OF THE LISTED OPTIONS

Explanation: You did not specify one of the listed options.

User Response: Enter one of the listed options.

SPMSG210 MUST BE NUMERIC. TYPE=ACTION - FIELD MUST BE NUMERIC

Explanation: The value you specified was not numeric.

User Response: Specify a numeric value.

SPMSG211 ENTER REQUIRED FIELD. TYPE=ACTION - ENTER DAY AND/OR YEAR FIELD(S)

Explanation: You have omitted a required field.

User Response: Specify a day and/or year value.

SPMSG214 MUST BE *** OR NUM - FIELD MUST BE NUMERIC OR ***

Explanation: The field needs to be either numeric or ***.

User Response: Specify either a numeric value or ***.

SPMSG215 MUST BE *** - ROW AND COLUMN FIELDS MUST MATCH IF *** IS SPECIFIED FOR COLS

Explanation: The row and column fields must match if one of them is ***.

User Response: Specify *** for both row and column.

SPMSG216 MUST BE ** - IF DATE SCREEN ID IS **, ID LOCATION ROW & COL MUST BE **

Explanation: Row and column fields must both be ** if date screen id is **.

User Response: Specify ** for both row and column.

SPMSG217 MUST BE NON BLANK - SCREEN ID FIELD MUST BE NON BLANK

Explanation: The screen id field cannot be blank.

User Response: Enter a value in the screen id field.

SPMSG218 MUST BE NON BLANK - DATE ID FIELD MUST BE NON BLANK

Explanation: The date id field cannot be blank.

User Response: Enter a value in the date id field.

SPMSG219 MUST BE Y OR N - WEEKDAY FIELD MUST BE Y OR N

Explanation: The weekday field must be Y or N.

User Response: Specify either Y or N in the weekday field.

Page 228: Hiperstation Messages and Codes

5-40 Hiperstation Messages and Codes

SPMSG220 DAY & YEAR REQUIRED - DAY AND YEAR FIELDS MUST BE ENTERED FOR JULIAN DATE

Explanation: You have not specified the required day and year fields.

User Response: Enter day and year fields in Julian form.

SPMSG230 TO VALUE CANNOT BE SAME AS FROM VALUE

Explanation: The TO value you specified cannot match the FROM value.

User Response: Change the TO value to something other than the FROM value.

SPMSG233 THIS FIELD MUST BE Y WHEN AUTOSKIP = Y

Explanation: The value you specified is invalid when AUTOSKIP=Y.

User Response: Change the value to Y as well.

SPMSG235 INPUT FIELD NUMBER AND LOCATION ARE MUTUALLY EXCLUSIVE, SPECIFY ONLY ONE.

Explanation: You have specified two mutually exclusive values, which is invalid.

User Response: Specify either the Input Field Number, or the Location.

SPMSG236 MUST BE ** OR NUMERIC IN THE RANGE 1 THRU 43

Explanation: The value you specified is invalid.

User Response: Use either ** or a numeric from 1 to 43.

SPMSG237 MUST BE *** OR NUMERIC IN THE RANGE 1 THRU 132

Explanation: The value you specified is invalid.

User Response: Use either *** or a numeric from 1 to 132.

SPMSG238 ROW AND COLUMN MUST BE BOTH NUMERIC OR ALL *

Explanation: The values you specified are invalid.

User Response: Change the row and column values to wither numerics or all *.

SPMSG241 MUST BE NUMERIC IN THE RANGE OF 0 THRU 43

Explanation: The value you specified is invalid.

User Response: Change the value to a numeric form 0 to 43.

SPMSG242 MUST BE NUMERIC IN THE RANGE OF 0 THRU 132

Explanation: The value you specified is invalid.

User Response: Change the value to a numeric form 0 to 132.

SPMSG243 MUST BE NUMERIC IN THE RANGE OF 1 THRU 43

Explanation: The value you specified is invalid.

User Response: Change the value to a numeric form 1 to 43.

SPMSG244 MUST BE NUMERIC IN THE RANGE OF 1 THRU 132

Explanation: The value you specified is invalid.

User Response: Change the value to a numeric form 1 to 132.

SPMSG245 DAY AND MONTH MUST BE ENTERED FOR JULIAN DATE

Explanation: You have omitted the day and month values.

User Response: Enter day and month values, in Julian format.

SPMSG246 DAY AND/OR YEAR MUST BE ENTERED

Explanation: You have omitted the day and/or year values.

User Response: Enter the missing day and/or year values.

Page 229: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-41

SPMSG248 BOTH ROW AND COLUMN MUST BE ENTERED

Explanation: You have omitted row and/or column values.

User Response: Enter row and/or column values.

SPMSG250 ENTER INPUT FIELD NUMBER (1-999) OR LOCATION ROW,COL (1-43,1-132)

Explanation: You have omitted a input field number or location value.

User Response: Use an input field number from 1 to 999, or location row,col (1 to 43, 1 to 132).

SPMSG251 ENTER INPUT FIELD NUMBER (1-999)

Explanation: You did not specify an input field number.

User Response: Specify an input field number from 1 to 999.

SPMSG252 ENTER INPUT FIELD LOCATION ROW,COL (1-43, 1-132)

Explanation: You have not specified an input field location.

User Response: Specify row,col (1 to 43, 1 to 132).

SPMSG253 INCONSISTENT INPUT FORMATS. USE EITHER LOGICAL OR ROW,COL FORMAT (NOT BOTH).

Explanation: You have used inconsistent input formats, which is invalid.

User Response: Use EITHER logical OR row,col format.

SPMSG257 MUST BE *** OR NUMERIC IN THE RANGE 1 THRU 132

Explanation: The value you specified is invalid.

User Response: Use *** or a numeric from 1 to 132.

SPMSG258 BOTH ROW AND COLUMN MUST BE NUMERIC OR ALL *

Explanation: The row and column values you specified are invalid.

User Response: Use either numerics or all *.

SPMSG259 MUST BE ** OR NUMERIC IN THE RANGE 1 THRU 43

Explanation: The value you specified is invalid.

User Response: Use either ** or numerics from 1 to 43.

SPMSG261 MUST BE Y OR N

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

SPMSG262 MUST BE NUMERIC IN THE RANGE 1 THRU 14

Explanation: The value you specified is invalid.

User Response: Use a numeric from 1 to 14.

SPMSG263 MUST BE NUMERIC IN THE RANGE 0 THRU 43

Explanation: The value you specified is invalid.

User Response: Use a numeric from 0 to 43.

SPMSG264 MUST BE NUMERIC IN THE RANGE 0 THRU 132

Explanation: The value you specified is invalid.

User Response: Use a numeric from 0 to 132.

SPMSG265 MUST BE NUMERIC IN THE RANGE 1 THRU 43

Explanation: The value you specified is invalid.

User Response: Use a numeric from 1 to 43.

Page 230: Hiperstation Messages and Codes

5-42 Hiperstation Messages and Codes

SPMSG266 MUST BE NUMERIC IN THE RANGE 1 THRU 132

Explanation: The value you specified is invalid.

User Response: Use a numeric from 1 to 132.

SPMSG267 DAY AND/OR YEAR IS REQUIRED

Explanation: You have omitted the day and/or year.

User Response: Specify day and/or year values.

SPMSG268 DAY AND YEAR IS REQUIRED FOR JULIAN DATE

Explanation: You have omitted the day and year values.

User Response: Specify day and year values in Julian format.

SPMSG269 WHEN SCREENID IS *, ROW MUST BE ** AND COL ***

Explanation: The values you specified are invalid.

User Response: Use ** for row and *** for column when screen ID is *.

SPMSG270 BOTH INPUT AND OUTPUT LOCATION CANNOT BE BLANK. ENTER AT LEAST ONE OF THEM

Explanation: You have omitted a location value.

User Response: Specify an input location and/or an output location.

SPMSG271 BOTH INPUT AND OUTPUT FILE INFORMATION CANNOT BE BLANK

Explanation: You have omitted a value.

User Response: Specify the input and/or the output file information.

SPMSG272 IF ROW NUMBER IS ZERO, COLUMN NUMBER MUST BE ZERO

Explanation: A value you specified is invalid at this time.

User Response: Change the column number to zero.

SPMSG273 IF COLUMN NUMBER IS ZERO, ROW NUMBER MUST BE ZERO

Explanation: A value you specified is invalid at this time.

User Response: Change the row number to zero.

SPMSG274 MONTH IS REQUIRED WHEN DAY AND/OR YEAR IS ENTERED

Explanation: A month value is required on this screen.

User Response: Specify a value for month when the day and/or year is present.

SPMSG275 DATE LOCATION IS VALID ONLY WHEN PROCESSING OUTPUT DATES, PLEASE BLANK OUT

Explanation: The date location you specified is not valid at this time.

User Response: Blank out the date location.

SPMSG276 MUST BE Y(YES) OR N(NO)

Explanation: The value you specified is invalid.

User Response: Use either Y or N.

SPMSG279 THIS FIELD IS INVALID WHEN PROCESSING OUTPUT DATES, PLEASE SPACE IT OUT

Explanation: The value you specified is invalid at this time.

User Response: Space out the field when processing output dates.

SPMSG280 MUST ENTER EITHER OR BOTH INPUT AND OUTPUT DATE CHANGE INFORMATION

Explanation: You have omitted an entry on this screen.

User Response: Enter input and/or output date change information.

Page 231: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-43

SPMSG281 MUST BE NUMERIC IN THE RANGE 1 THRU 43

Explanation: The value you specified is invalid.

User Response: Use a number from 1 to 43.

SPMSG282 MUST BE NUMERIC IN THE RANGE 1 THRU 132

Explanation: The value you specified is invalid.

User Response: Use a number from 1 to 132.

SPMSG283 MUST BE NUMERIC IN THE RANGE 1 THRU 60

Explanation: The value you specified is invalid.

User Response: Use a number from 1 to 60.

SPMSG284 LENGTH OF THE DATA ENTERED CANNOT EXCEED CONSTANT LENGTH PARAMETER VALUE

Explanation: The value you specified has exceeded its maximum length.

User Response: Keep the length under the CONSTANT LENGTH parameter value.

SPMSG285 SCREENID IS REQUIRED (WILDCARDING IS NOT ALLOWED)

Explanation: You have omitted the screen ID.

User Response: Replace your wildcard with a valid screen ID.

SPMSG286 THIS FIELD IS REQUIRED WHEN PROCESSING OUTPUT DATES. VALID VALUES ARE Y OR N

Explanation: You have omitted a required field when processing output dates.

User Response: Use Y or N in the required field.

SPMSG288 THIS PARAMETER IS VALID ONLY WHEN PROCESSING OUTPUT DATES, PLEASE BLANK IT OUT

Explanation: You have specified a parameter which is invalid at this time.

User Response: Blank out this parameter and try again.

SPMSG289 WHEN PROCESSING OUTPUT DATE WITH OVERLAY=N, THIS FORMAT IS INVALID. ENTER ANOTHER FORMAT OR SPECIFY OVERLAY=Y

Explanation: The format you specified is invalid with OVERLAY=N.

User Response: Use another format, or specify OVERLAY=Y.

SPMSG305 INVALID FILE TYPE - THE CONTROL FILE MUST HAVE DSORG OF PO OR PS

Explanation: The file type you specified is invalid.

User Response: Make sure the control file has a DSORG of PO or PS.

SPMSG306 MISSING MEMBER NAME - THE CONTROL FILE IS A PDS, MEMBER NAME REQUIRED

Explanation: You have omitted the member name for the control file.

User Response: Specify a member name for the PDS.

SPMSG307 INVALID FILE TYPE - &FILENAME IS NOT A PARTITIONED DATASET (PDS)

Explanation: The file you specified is not a PDS.

User Response: Specify a PDS with a member name.

SPMSG308 OUTPUT SCRIPT EXISTS - &FILENAME ALREADY EXISTS

Explanation: The filename you specified already exists.

User Response: Either specify a new filename, or delete the existing file and try again.

SPMSG309 DELAY TIME REQUIRED - IF ACTION IS WAIT< THEN DELAY TIME IS REQUIRED

Explanation: You have omitted a required value.

Page 232: Hiperstation Messages and Codes

5-44 Hiperstation Messages and Codes

User Response: Specify the delay time when ACTION is WAIT.

SPMSG404 USE / TO SELECT - THE SELECTION CHARACTER IS A /

Explanation: The selection character you specified is invalid.

User Response: Use / to select.

SPMSG405 SELECT ONLY 1 - PLEASE SELECT JUST ONE OF THE CHOICES

Explanation: You have selected more than one choice.

User Response: Select only one of the choices.

SPMSG406 INVALID FILE TYPE - THE REPORT FILE MUST HAVE DSORG OF PO OR PS

Explanation: The file type you specified is invalid.

User Response: Use a DSORG of PO or PS for the report file.

SPMSG407 MISSING MEMBER NAME - THE REPORT FILE IS A PDS, MEMBER NAME REQUIRED

Explanation: You have omitted a member name for the report file.

User Response: Specify a PDS with a member name.

SPMSG500 MUST BE Y OR N - LIST FIELD MUST BE Y OR N

Explanation: The value you specified for the LIST field is invalid.

User Response: Use Y or N for the LIST field.

SPMSG501 MUST SPECIFY NUMERIC - MUST SPECIFY NUMERIC VALUE

Explanation: The value you specified is invalid.

User Response: Specify a numeric value.

SPMSG502 MUST BE NUMERIC - MUST BE NUMERIC VALUE

Explanation: The value you specified is invalid.

User Response: Specify a numeric value.

SPMSG503 MUST BE NUMERIC - MUST BE NUMERIC VALUE

Explanation: The value you specified is invalid.

User Response: Specify a numeric value.

SPMSG504 MUST SPECIFY NUMERIC - MUST SPECIFY NUMERIC VALUE

Explanation: The value you specified is invalid.

User Response: Specify a numeric value.

SPPARMSPPARM005 EXEC_PDS ERROR

Explanation: The parameter EXEC_PDS in the SPPARMS program is in error. The error description should be included in the text of this message. SPPARMS is the parameter table for the script processor. It is a member of the EXEC library.

User Response: Change the value of LOW_YEAR appropriately.

SPPARM010 LOW_YEAR FIELD NOT NUMERIC

Explanation: The parameter LOW_YEAR in the SPPARMS program is not numeric. SPPARMS is the parameter table for the script processor. It is a member of the EXEC library.

User Response: Change the value of LOW_YEAR appropriately.

Page 233: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-45

SPPARM020 HIGH_YEAR FIELD NOT NUMERIC

Explanation: The parameter HIGH_YEAR in the SPPARMS program is not numeric. SPPARMS is the parameter table for the script processor. It is a member of the EXEC library.

User Response: Change the value of HIGH_YEAR appropriately.

SVABNSVABN100E ABEND COUNT EXCEEDED, WITHDRAWAL RECOMMENDED

Explanation: The SessionView ABEND Monitor has detected that the ABEND count has exceeded its limit.

User Response: Shut down the process.

SVACFSVACF912I EXIT NOT FREED XXXX A:YYYYYYYY L:ZZZZZZZZ RC:NNNN

Explanation: Global Recording was unable to release storage for a User ID Tracking exit. A is the address where the exit is located. L is the length. RC is the FREEMAIN return code.

User Response: Contact Compuware Customer Support.

SVACF913I EXIT CHANGED XXXX E:YYYYYYYY A:ZZZZZZZZ

Explanation: Global Recording detected another ACF2 exit that was installed after User ID Tracking was installed. E is the expected address of the exit. A is the actual address in the ACCVT.

System Action: To preserve system integrity, the exit Global Recording installed is left in place, but disabled.

User Response: This is an informational message. No action required.

SVACF990I ACF2 RELIEF PROCESSING STARTED

Explanation: User ID Tracking has acknowledged the Global Recording shutdown request.

User Response: This is an informational message. No action required.

SVACF991I ACF2 RELIEF PROCESSING COMPLETE

Explanation: Shutdown of User ID Tracking is complete.

User Response: This is an informational message. No action required.

SVATHSVATH001I TASK ATTACHED - XXXXXXXX

Explanation: A module (XXXXXXXX) has been invoked and is currently processing.

User Response: Informational message. No user action necessary.

SVATH002E PROGRAM NOT FOUND

Explanation: A subtask specified on an ATTACH statement in the GRPARMS member was not found within the load library.

User Response: Verify that the correct subtask name is specified on the ATTACH statements within the GRPARMS member. Reference the Hiperstation Installation and Configuration Guide for a list of valid subtasks.

Page 234: Hiperstation Messages and Codes

5-46 Hiperstation Messages and Codes

SVATH003W TASK taskname NOT ATTACHED (NOVTAM SPECIFIED)

Explanation: An ATTACH for SVNETREC or SVUSEREC was specified in the GRPARMS member, but the NOVTAM parameter was also present. These values are mutually exclusive since SVNETREC is the subtask that collects VTAM traffic. The Attach request will be ignored.

User Response: If capture of VTAM traffic is intended, remove or comment out the NOVTAM parameter in the GRPARMS member. If capture of VTAM traffic is not required, remove or comment out the ATTACH statement for SVNETREC. In addition to SVNETREC, subtask SVUSEREC (logon/logoff activity) is also related to VTAM traffic, and the need for an associated ATTACH statement should be reviewed.

SVATH004W TASK taskname NOT ATTACHED (ALREADY ATTACHED)

Explanation: An ATTACH was specified in the GRPARMS member, but the same ATTACH had been already executed. The duplicate attach request will be ignored.

User Response: Remove the duplicated ATTACH parameter in the GRPARMS member.

SVDELSVDEL101E DELETE OPER FAILED - RC=return code

Explanation: An error occurred during a delete from the Global Record archive file. All records up until the error occurred were deleted, and the process stopped.

User Response: Reissue the delete command. You may receive this error code again; continue to reissue the command until all files are deleted. It may take several tries to delete a large number of records.

SVMANSVMAN101I xxxx RELOCATION COMPLETE yyyyyyyy

Explanation: Program xxxx was internally relocated. yyyyyyy is an internal address.

User Response: Informational message. No user action necessary.

SVMAN105I HIPERSTATION SUBSYSTEM ACTIVATION COMPLETE, VERSION CCCCCCCC

Explanation: The global recording task was started.

SVMAN206I SVMAIN20 NOT APF AUTHORIZED, INITIALIZATION ABANDONED

Explanation: The global recording task was started and the task detected that the Hiperstation load modules do not reside in an authorized library. The task is terminated.

User Response: Authorize the Hiperstation load library via the methods outlined in the Hiperstation Installation and Configuration Guide.

SVMAN211I HIPERSTATION SUBSYSTEM IS NOT ACTIVE

Explanation: Informational message displayed during Global Record shutdown.

SVMAN218I TASK cccccccc WAS ATTACHED AT mm/dd/yy hh/mm/ss xxxxxxxx

Explanation: This message is issued when the TASKS command is processed. The subtask (cccccccc) was attached at the chosen date and time. Its internal control block address is xxxxxxxx.

SVMAN219I TASK XXXXXXXX DETACHED, RETURN CODE=nnnnnnnn

Explanation: The subtask XXXXXXXX was detached with a return code of nnnnnnnn.

User Response: Informational message. No user action necessary. This message appears when the TASKS command is processed.

Page 235: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-47

SVMAN231W GLOBAL RECORDING BUFFER ALLOCATION 80.0% OF AVAILABLE ECSA

Explanation: Over 80% of available ECSA is about to be allocated to Hiperstation capture buffers. Note: Available ECSA may be so fragmented that Hiperstation fails to allocate its ECSA buffers and therefore fails to initialize; no warning message may appear.

User Response: To resolve this issue, either increase the size of ECSA or reduce ECSA usage.For information on increasing ECSA size, review IBM’s MVS Initialization and Tuning Reference regarding the CSA parameter in SYS1.PARMLIB member IEASYSxx. Note: Increasing ECSA generally reduces the size of EPVT (Extended Private) storage. To reduce ECSA usage, review the Hiperstation started task initialization parameters that set the size of ECSA capture buffers. Refer to the Hiperstation Installation and Configuration Guide.

• VTAM/AllNet parameters: Reduce the product of number of buffers (ALLNBUFS) and size (ALLNBUFL). If these are set too low, lost PIU message SVNET304W appears.

• TCP/IP and MQSeries parameters: Reduce the product of number of buffers (TCPBUFS) and size (TCPBUFL). If these are set too low, lost buffer message TCPRC100W appears.

SVMAN232I ALLNET ALLOCATION (nnnnnnK) TCP+MQ ALLOCATION (nnnnnnK) ECSA AVAILABLE (nnnnnnK)

Explanation: Related to SVMAN321W, describes allocation in Kilobytes of ALLNET, TCP/IP, MQSeries, and ECSA. Note: Available ECSA may be so fragmented that Hiperstation fails to allocate its ECSA buffers and therefore fails to initialize; no warning message may appear.

User Response: Informational message. No user action necessary.

SVMAN352E UNABLE TO LOCATE TSEB

Explanation: Hiperstation was unable to locate a TCP/IP region that was specified on the TCPIP(jobname) SYSIN parameter.

User Response: Verify that all TCP/IP jobnames specified for monitoring are up and running or remove them from the TCP/IP SYSIN parameter.

SVMAN353E TCP/IP HOOKING ERROR

Explanation: Hiperstation was unable to initialize TCP/IP support.

User Response: Look for other Hiperstation messages in the console log. Be sure that all TCP/IP regions are running and that the correct Open Edition jobname is specified on the OMVS SYSIN parameter.

SVMAN354E SRB COULD NOT LOCATE MTBL

Explanation: Hiperstation could not locate the information necessary to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN355E SRB COULD NOT LOCATE HOOK MODULE

Explanation: Hiperstation could not locate the information necessary to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN356E UNKNOWN SRB ERROR XXXXXXXX

Explanation: Hiperstation could not locate the information necessary to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN357E CANNOT FIND OMVS ASCB

Explanation: Hiperstation could not locate the information necessary to initialize TCP/IP support.

User Response: Verify that the correct jobname for the Open Edition address space is in the OMVS(jobname) SYSIN parameter.

Page 236: Hiperstation Messages and Codes

5-48 Hiperstation Messages and Codes

SVMAN359E SRB UNRECOGNIZED CODE IN MODULE

Explanation: Hiperstation could not locate the information necessary to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN360I USER KEY CSA IS DISABLED

Explanation: The NOUSERKEYCSA diagnostic bit is set on your system.

User Response: Informational message. No user action necessary.

SVMAN374I MODULE XXXXXXXX NOT FOUND IN LPA

Explanation: Hiperstation could not locate the modules necessary to initialize Secure Sockets Layer support. Compuware will continue to run without SSL support.

User Response: Verify that the correct modules required for SSL support have been loaded into the LPA as specified in the Hiperstation Installation and Configuration Guide. If SSL is not desired remove the SSL SYSIN parameter to avoid this message in the future. This message can be ignored if no SSL is desired.

SVMAN376I ERROR MODIFYING LPA

Explanation: Hiperstation could not locate the correct information necessary to initialize Secure Sockets Layer support. Hiperstation will continue to run without SSL support.

User Response: Verify that the correct version of the modules required for SSL support have been loaded into the LPA as specified in the Hiperstation Installation and Configuration Guide. If SSL is not desired remove the SSL SYSIN parameter to avoid this message in the future. If it appears that the correct version of the required modules are in the LPA, contact Compuware Customer Support.

SVMAN377E UNABLE TO LOCATE TSDB

Explanation: Hiperstation was unable to locate information necessary to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN378E UNABLE TO INITIALIZE TCP/IP

Explanation: Hiperstation was unable to initialize TCP/IP support.

User Response: Look for other Hiperstation messages in the console log. Be sure that all TCP/IP regions are running and that the correct Open Edition jobname has been specified on the OMVS SYSIN parameter.

SVMAN379E INITAPI ERROR XXXXXXXX

Explanation: Hiperstation was unable to initialize TCP/IP support.

User Response: Look for other Hiperstation messages in the console log. Be sure that all TCP/IP regions are running and that the correct Open Edition jobname has been specified on the OMVS SYSIN parameter.

SVMAN380E GETHOSTID FAILED

Explanation: Hiperstation was unable to initialize TCP/IP support.

User Response: Look for other Hiperstation messages in the console log. Be sure that all TCP/IP regions are running and that the correct Open Edition jobname has been specified on the OMVS SYSIN parameter.

SVMAN381I OPTIONAL HOOK POINT XXXXXXXX BYPASSED

Explanation: Hiperstation was unable to locate the information necessary for the specified function. This is probably caused by an older version of TCP/IP that has less functionality than is supported.

User Response: This message can be ignored.

Page 237: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-49

SVMAN382E REQUIRED HOOK POINT XXXXXXXX NOT FOUND

Explanation: Hiperstation was unable to locate the necessary information to initialize TCP/IP support.

User Response: Contact Compuware Customer Support.

SVMAN384E ERROR MODIFYING CSA

Explanation: Hiperstation could not locate the information required to initialize MQSeries support.

User Response: Contact Compuware Customer Support.

SVMAN386E MQSERIES HOOKING ERROR

Explanation: Hiperstation was unable to initialize MQSeries support.

User Response: Check console log for additional informational messages. Verify that the startup parameters in the appropriate GRPARMS member are correct. If the problem persists, contact Compuware Customer Support. Note: Your site may be using GRPARMS, GRPARMS1, GRPARMS2, or GRPARMS3.

SVMAN387E MQSERIES QUEUE MANAGER NOT FOUND

Explanation: The subsystem specified in the MQSeries parameter in GRPARMS was not found in the subsystem table.

User Response: Verify that the subsystem specified is valid. If it appears the subsystem is valid and defined in the MVS subsystem control table, contact Compuware Customer Support.

SVMAN388E NOT LICENSED FOR MQSERIES SUPPORT

Explanation: The MQSERIES() parameter is present in GRPARMS, but your site is not licensed for MQSeries support. Hiperstation ignores the parameter.

User Response: Remove the MQSeries parameter from GRPARMS, or contact your sales representative about licensing this product option.

SVMAN389E NOT LICENSED FOR TCP/IP SUPPORT

Explanation: The TCPIP() parameter is present in GRPARMS, but your site is not licensed for TCP/IP support. Hiperstation ignores the parameter.

User Response: Remove the TCPIP parameter from GRPARMS, or contact your sales representative about licensing this product option.

SVMAN391I type CAPTURE REQUESTED

Explanation: The control card is being processed. Type is either MQSERIES, TCPIP, or VTAM.

User Response: Informational message. No user action necessary.

SVMAN392W SSL MODULE NOT FOUND, SSL RECORDING MAY NOT BE ACTIVE

Explanation: Hiperstation could not locate the correct information necessary to initialize Secure Sockets Layer support. Hiperstation will continue to run without SSL support.

User Response: Verify that the correct version of the modules required for SSL support have been loaded into the LPA as specified in the Hiperstation Installation and Configuration Guide. If SSL is not desired remove the SSL SYSIN parameter to avoid this message in the future. If it appears that the correct version of the required modules are in the LPA, contact Compuware Customer Support.

SVMAN393E TCPNBUF/TCPBUFL REQUIRED FOR TCPIP

Explanation: Either TCPNBUF or TCPBUFL has been set to zero. Each parameter must have a valid value to initialize TCP/IP.

User Response: Set TCPNBUF and TCPBUFL to valid values.

SVMAN394E TCPNBUF/TCPBUFL REQUIRED FOR MQSERIES

Explanation: Either TCPNBUF or TCPBUFL has been set to zero. Each parameter must have a valid value to initialize MQSeries.

User Response: Set TCPNBUF and TCPBUFL to valid values.

Page 238: Hiperstation Messages and Codes

5-50 Hiperstation Messages and Codes

SVMAN395E ALLNBUF/ALLBUFL REQUIRED FOR VTAM

Explanation: Either ALLNBUF or ALLBUFL has been set to zero. Each parameter must have a valid value to initialize VTAM.

User Response: Set ALLNBUF and ALLBUFL to valid values.

SVMAN396E NO CAPTURE SUBSYSTEMS STARTED

Explanation: None of the capture subsystems (VTAM, TCP/IP, or MQSeries) have been requested.

User Response: Review prior messages and correct the invalid or missing control statements.

SVMAN397E GLOBAL RECORD IS STOPPING

Explanation: Global recording is stopping due to prior errors.

User Response: Review prior messages and correct the invalid or missing control statements.

SVMAN501I HIPERSTATION WITHDRAWN FROM ACTIVE MONITORING

Explanation: Hiperstation’s VTAM monitor program has been removed from the system.

SVMAN502I HIPERSTATION ALREADY WITHDRAWN

Explanation: Hiperstation tried to remove its VTAM monitor program from the system, but found that it has already been withdrawn.

SVMAN601I HIPERSTATION SUBSYSTEM IS ALREADY ACTIVE

Explanation: It must be shutdown for a startup to take place.

User Response: Shut the subsystem down or ignore the message.

SVMAN602I IT MUST BE SHUTDOWN FOR A STARTUP TO TAKE PLACE

Explanation: This informational message accompanies SVMAN601I.

SVMAN603I START HIPERSTATION USING SHUTDOWN AS THE EXEC PARAMETER

SVMAN604I WHEN SHUTDOWN COMPLETES, RESTART NORMALLY

Explanation: An attempt was made to start the global recording task. The task determined that another global recording task was already active in another address space.

User Response: Verify that global recording is active in another address space. If it is not active, then the original task has terminated abnormally or withdrawn incorrectly. Check the system log for error messages. To restart global recording, you must start the task with the SHUTDOWN parameter. After the shutdown is complete, restart normally. The SHUTDOWN parameter is described in the Hiperstation Installation and Configuration Guide.

SVMAN610I HIPERSTATION SUBSYSTEM IS STILL ACTIVE IN ANOTHER ADDRESS SPACE

Explanation: Hiperstation Global Record is already running in another address space. Only one instance of Hiperstation Global Record can execute within an MVS LPAR.

SVMAN611I PLEASE USE THE MVS STAP (P) COMMAND TO TERMINATE HIPERSTATION

Explanation: Hiperstation Global Record is already running in another address space.

User Response: Use the MVS STOP (P) command to terminate it.

SVMAN702I HIPERSTATION TERMINATING

Explanation: Hiperstation Global Record is shutting down.

SVMAN703I NEXT TIME, PLEASE USE THE MVS STOP (P) COMMAND TO TERMINATE HIPERSTATION

Explanation: The Global Record task ended due to an x22 abend, for example, an address space was cancelled.

SVMAN800I STATISTICS PROCESSING ACTIVATED

Explanation: A "STATSON" command has been issued and statistics processing has started.

Page 239: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-51

SVMAN801I STATISTICS PROCESSING TERMINATED

Explanation: A "STATSOFF" command has been issued and statistics processing has terminated.

SVMAN802E STATISTICS PROCESSING ALREADY ACTIVE

Explanation: A "STATSON" command has been issued when statistics processing is already started.

SVMAN803E STATISTICS PROCESSING NOT ACTIVE

Explanation: A "STATSOFF" command has been issued but statistics processing is not active.

SVMAN805I STATISTICS DATASET OPENED

Explanation: A "STATSON" or "STATOPEN" command has been issued to open the statistics dataset or SYSOUT.

SVMAN806E STATISTICS DATASET NOT CLOSED

Explanation: A "STATOPEN" command has been issued but the statistics dataset/SYSOUT is already opened.

SVMAN807E STATISTICS DATASET OPEN FAILED

Explanation: A "STATSON" or "STATOPEN" command has been issued but the OPEN failed.

User Response: Check the dataset name entered on the STATSON or STATOPEN command and/or check for a STATDD in the JCL. Re-issue the command.

SVMAN810I STATISTICS DATASET CLOSED

Explanation: A "STATSOFF" or "STATCLOS" command has been issued and statistics dataset has been closed.

SVMAN811E STATISTICS DATASET NOT OPEN

Explanation: A "STATCLOS" command has been issued but the statistics dataset was not open.

SVMAN815I STATISTICS FREQUENCY ALTERED

Explanation: A "STATFREQ" command has been issued to change the statistics output frequency.

SVMAN816E STATISTICS FREQUENCY NOT VALID

Explanation: A "STATFREQ" command has been issued with an invalid frequency.

User Response: Reenter the command with a numeric frequency.

SVMAN820I STATISTICS MONITOR STARTED

Explanation: A "MONON" command has been issued and statistics monitoring has started.

SVMAN821I STATISTICS MONITOR TERMINATED

Explanation: A "MONOFF" command has been issued and statistics monitoring has terminated.

SVMAN822E STATISTICS MONITOR ALREADY ACTIVE

Explanation: A "MONON" command has been issued but statistics monitoring is active.

SVMAN823E STATISTICS MONITOR NOT ACTIVE

Explanation: A "MONOFF" command has been issued but statistics monitoring is not active.

SVMAN999I HIPERSTATION SUBSYSTEM SHUTDOWN COMPLETE

Explanation: The Hiperstation Global Recording shutdown process had completed.

Page 240: Hiperstation Messages and Codes

5-52 Hiperstation Messages and Codes

SVMANTSSVMANTS1I UNABLE TO FIND ROUT

Explanation: Hiperstation was able to locate the module necessary to initialize Secure Sockets Layer support but could not locate one of the necessary routines.

User Response: Verify that the correct version of the modules required for SSL support have been loaded into the LPA as specified in the Hiperstation Installation and Configuration Guide. If SSL is not desired remove the SSL SYSIN parameter to avoid this message in the future. If it appears that the correct version of the required modules are in the LPA, contact Compuware Customer Support.

SVMAPSVMAP001I SCANNING SYSIN CONTROL STATEMENTS

Explanation: The SYSIN control statements are being scanned and parsed for validity.

User Response: Informational message. No user action necessary.

SVMAP002I SYSIN CONTROL STATEMENT SCAN COMPLETE

Explanation: The SYSIN control statements have been scanned and parsed.

User Response: Informational message. No user action necessary.

SVMAP003E INVALID NUMERIC VALUE

Explanation: A non-numeric value was provided for the keyword specified in the preceding SVMAP101I message.

System Action: Hiperstation uses the default value until the offending value is corrected.

User Response: Correct the value of the keyword in the GRPARMS member your site is using. Refer to the Hiperstation Installation and Configuration Guide for help with determining the correct value.

SVMAP004E NUMERIC KEYWORD VALUE IS TOO SMALL, DEFAULT ASSUMED

Explanation: The numeric value for the keyword specified in the preceding SVMAP101I message is below the valid range.

System Action: Hiperstation uses the default until the offending value is corrected.

User Response: Correct the value of the keyword in the GRPARMS member your site is using. Refer to the Hiperstation Installation and Configuration Guide for help with determining the correct value.

SVMAP005E NUMERIC KEYWORD VALUE IS TOO LARGE, DEFAULT ASSUMED

Explanation: The numeric value for the keyword specified in the preceding SVMAP101I message is above the valid range.

System Action: Hiperstation uses the default until the offending value is corrected.

User Response: Correct the value of the keyword in the GRPARMS member your site is using. Refer to the Hiperstation Installation and Configuration Guide for help with determining the correct value.

SVMAP006E KEYWORD VALUE TOO LONG, VALUE TRUNCATED

Explanation: The value supplied for the keyword specified in the preceding SVMAP101I message exceeds the maximum allowable length.

System Action: Hiperstation uses the truncated value until the offending value is corrected.

User Response: Correct the value of the keyword in the GRPARMS member your site is using. Refer to the Hiperstation Installation and Configuration Guide for help with determining the correct value.

Page 241: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-53

SVMAP007W MISSING KEYWORD VALUE

Explanation: The keyword specified in the preceding SVMAP101I message is missing a required parameter.

System Action: When possible, Hiperstation uses the default value. Otherwise, the Global Recorded started task terminates.

User Response: Correct the value of the keyword in the GRPARMS member your site is using and if necessary restart the Global Recording started task. Refer to the Hiperstation Installation and Configuration Guide for help with both of these tasks.

SVMAP008E SECSYS VALUE INVALID. MUST BE RACF, ACF2, OR TOPSEC

Explanation: An invalid security package value was specified for the SECSYS keyword.

System Action: Hiperstation attempts to use RACF. If RACF is not your security package, Hiperstation produces the SVRAC999E error message and terminates the Global Recording started task.

User Response: Correct the value of the keyword in the GRPARMS member your site is using. Valid values are RACF, ACF2, or TOPSEC. If necessary, restart the Global Recording started task.

SVMAP009W USERCNT IS NO LONGER USED. PLEASE REMOVE IT FROM GRPARMS

Explanation: USERCNT is no longer used.

System Action: The USERCNT keyword is ignored.

User Response: Remove the keyword in the GRPARMS member your site is using.

SVMAP010W USERBUF IS NO LONGER USED. PLEASE REMOVE IT FROM GRPARMS.

Explanation: USERBUF is no longer used.

System Action: The USERBUF keyword is ignored.

User Response: Remove the keyword in the GRPARMS member your site is using.

SVMAP101I xxxxx(yyy)

Explanation: The SYSIN parameter xxxxx and its parameter yyy has been parsed.

User Response: Informational message. No user action necessary.

SVMNANETSVMNANET GETTING VSBF... ADDR:XXXXXXXX KEY:XX LEN:XXXXXXXX SP:XX RC:XXXX

Explanation: Global Recording could not allocate ECSA storage for recording buffers. ADDR: is the storage address. KEY: is the storage key requested. LEN: is the amount of storage, in HEX. SP: is the subpool ID. RC: is the return code from GETMAIN.

System Action: Global Recording terminates.

User Response: For return code 0008, reduce ALLNBUFL in GRPARMS and restart Global Recording. For return code 000C, contact your MVS System Programmer. For all other return codes, contact Compuware Customer Support.

SVMSSVMS022 SSCP SESSION INVALID - THE SELECT COMMAND IS NOT VALID WITH SSCP SESSIONS, USE BROWSE OR TRACE

Explanation: The SELECT command is not valid at this time.

User Response: Use BROWSE or TRACE instead.

SVMS037 PRINT NOT ENABLED. USE THE PRT COMMAND TO ENABLE PRINTING

Explanation: Printing is not enabled at this time.

Page 242: Hiperstation Messages and Codes

5-54 Hiperstation Messages and Codes

User Response: Use PRT to enable printing.

SVMS049 NO HOSTS SELECTED - ONE OR MORE HOSTS MUST BE SELECTED WITH A "/"

Explanation: No hosts have been selected.

User Response: Use a / to select one or more hosts.

SVNETSVNET000I ALL-NET RECORDER ACTIVATED

Explanation: The ALL-NET recorder has been invoked and is now processing.

System Action: Informational message.

User Response: None.

SVNET001I INVALID KEYWORD, IGNORE

Explanation: The option specified is invalid and ignored.

System Action: None.

User Response: Correct error and rerun.

SVNET002I NORECORD OPTION SET

Explanation: The option, NORECORD specified has been set.

System Action: Informational message.

User Response: None.

SVNET003I NODATA OPTION SET

Explanation: The NODATA option is in effect.

System Action: Informational message.

User Response: None.

SVNET004I DEBUG OPTION SET

Explanation: The option, DEBUG specified has been set.

System Action: Informational message.

User Response: None.

SVNET005I TEST OPTION SET

Explanation: The option, TEST specified has been set.

System Action: Informational message.

User Response: None.

SVNET006I SPIKES OPTION SET

Explanation: The VTAM ECSA spike simulator option has been set.

System Action: Informational message.

User Response: None.

SVNET008I RESETTING ALL NADRS

Explanation: The NADR data structure is used internally by Hiperstation to keep track of active VTAM sessions in the MVS system. This structure contains PIU discard flag. This flag is used when there was no Global Recording Request satisfying the capture of the session and the subsequent messages will not be examined any further. When new Global Recording Request is added or restated, this flag has to be reset. If the request contains wild-carded filter, we have to reset all NADRs and this message will be sent to the Global Recording tasks log.

System Action: Informational message.

Page 243: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-55

User Response: None.

SVNET009I ALL-NET RECORDER SHUTDOWN ACKNOWLEDGED

Explanation: Received a shutdown request and start shutting down VTAM ECSA copier.

System Action: Informational message.

User Response: None.

SVNET304W ECSA BUFFERS NOT LARGE ENOUGH, nnnnnnnn PIUS Lost SO FAR

Explanation: The PIU collection buffers are full and no empty buffers were available. nnnnnnnn represents the number of data streams lost.

User Response: If this message occurs only at Global Record startup, and no 3270 or APPC requests are active, ignore this message. Otherwise, complete the following steps:

• Ensure the started task dispatch priority is below VTAM, but above all VTAM applications on the system. If WLM goal mode is active, dispatch rate is determined by the VELOCITY of the performance group. The IBM default group, SYSSTC, is a good starting point for most systems.

• Access the Statistics panel from the Hiperstation Product Menu panel by issuing the primary command STATS; then access the VTAM panel by issuing VTAM on the command line. Use the information displayed on this panel to determine how to modify the ECSA buffer settings. If your traffic volumes vary throughout the day, turn on the statistics function to evaluate volume trends. Refer to the Hiperstation Installation and Configuration Guide to learn more about monitoring traffic volume and optimizing Global Recording performance.

• If you do not capture APPC traffic, specify NOAPPC in GRPARMS to reduce buffer utilization.

• If you do not capture LU1/LU3 traffic, specify GRLU1CAP=NO in EHSDFLT to reduce buffer utilization.

• If you do not capture LU0 traffic, specify NOLU0 in GRPARMS to reduce buffer utilization.• If capture is on a production system, specify NONFLS in GRPARMS to enhance buffer

utilization and CPU usage.

SVNET401E BUFFER OVERRUN, PLEASE CALL HIPERSTATION CUSTOMER SUPPORT

Explanation: An error was detected in a PIU collection buffer.

User Response: Contact Compuware Customer Support. If possible, do not stop the started task; Compuware Customer Support may be able to gather important debugging information.

SVNET410I PIU EXIT xxxxxxxx INITIALIZED AT yyyyyyyy

Explanation: The module xxxxxxxx was initialized at yyyyyyyy.

User Response: Informational message. No user action necessary.

SVNET910I MORE NADRS NEEDED

Explanation: The NADR data structure is used internally by Hiperstation to keep track of active VTAM sessions in the MVS system. The initial number of NADRs obtained is controlled by the SESSCNT parameter in the Global Recording startup parameters. This message appears if Hiperstation has to keep track of more VTAM sessions than are specified on the SESSCNT parameter.

System Action: Hiperstation tries to obtain additional NADRs.

User Response: Eliminate this message by setting a SESSCNT value larger than the maximum number of simultaneous VTAM sessions on your system. For each occurrence of this message, increase the existing SESSCNT value by minimally 25%. For example, if the existing SESSCNT is 1000 and you receive three of these messages, increase the SESSCNT to 1750. Setting an appropriate SESSCNT value improves performance.

SVNET911I MORE NADRS OBTAINED

Explanation: The NADR data structure is used internally by Hiperstation to keep track of active VTAM sessions in the MVS system. The initial number of NADRs obtained is controlled by the SESSCNT parameter in the Global Recording startup parameters. This message appears if Hiperstation has obtained additional NADRS to keep track of more VTAM sessions than are specified on the SESSCNT parameter. If Hiperstation is not successful in obtaining more NADRs, this message does not appear.

Page 244: Hiperstation Messages and Codes

5-56 Hiperstation Messages and Codes

User Response: This message appears after message SVNET910I, providing the system is able to obtain more NADRs. The action required to eliminate SVNET910I also eliminates this message.

SVNET930W NULL VSBE DETECTED, BYPASSED

Explanation: During processing of a PIU collection buffer, an invalid PIU was encountered.

System Action: Processing of the related PIU collection buffer was halted.

User Response: Regular occurrence of this warning may indicate a serious issue and loss of PIUs. Contact Hiperstation Customer Support.

SVNET931W AN ECSA BUFFER HAS NOT BEEN FILLED UP YET.

Explanation: When an ECSA buffer becomes full, the Global Recording task empties the ECSA buffer. However, if the individual VSBE has not yet been completely copied, the Global Recording task displays this message. Then, it waits 1/100th second and re-examine whether the copy of VSBE has completed. If it fails after 100 attempts (approximately 1 sec), the SVNET932W message is displayed and processing continues. If the SVNET932W message does not appear, the copy of all VSBE completed successfully.

SVNET932W AN ECSA BUFFER MAY CONTAIN BAD VSBE(S).

Explanation: After checking for the completion of VSBE copy 100 times, VSBE copy had not completed.

SVNETCSVNETC99I ALL-NET COPIER SHUTDOWN COMPLETE

Explanation: The shutdown for VTAM ECSA copier has been completed.

System Action: Informational message.

User Response: None.

SVNETCPSVNETCP0I ALL-NET COPIER ACTIVATED

Explanation: The VTAM ECSA buffer copy program started.

System Action: Informational message.

User Response: None.

SVNETCP1I INVALID KEYWORD, IGNORE

Explanation: The option specified is invalid and ignored.

System Action: None.

User Response: Correct error and rerun.

SVNETCP2I NORECORD OPTION SET

Explanation: The option, NORECORD specified has been set.

System Action: Informational message.

User Response: None.

SVNETCP3I NODATA OPTION SET

Explanation: The option, NODATA specified has been set.

System Action: Informational message.

User Response: None.

Page 245: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-57

SVNETCP4I DEBUG OPTION SET

Explanation: The option, DEBUG specified has been set.

System Action: Informational message.

User Response: None.

SVNETCP5I TEST OPTION SET

Explanation: The option, TEST specified has been set.

System Action: Informational message.

User Response: None.

SVNETCP6I NONFLS OPTION SET

Explanation: The option, NONFLS specified has been set.

System Action: Informational message.

User Response: None.

SVNETCP8I RESETTING ALL NADRS

Explanation: The NADR data structure is used internally by Hiperstation to keep track of active VTAM sessions in the MVS system. This structure contains PIU discard flag. This flag is used when no Global Recording Request satisfies the capture of the session and the subsequent messages will not be examined any further. When a new Global Recording Request is added or restated, this flag must be reset. If the request contains wild-carded filter, we have to reset all NADRs and this message will be sent to the Global Recording tasks log.

System Action: Informational message.

User Response: None.

SVNETCP9I ALL-NET COPIER SHUTDOWN ACKNOWLEDGED

Explanation: Received a shutdown request and start shutting down VTAM ECSA copier.

System Action: Informational message.

User Response: None.

SVNETRECSVNETREC-DIAG ECSA BUFFER CONTAINS WRONG TH4DCF

Explanation: While capturing data, Global Recording detected an inconsistency between the SNA segment length (TH4DCF) and its own length field.

System Action: Global Recording uses its own length field when processing the data.

User Response: Check scripts created from any sessions that were recorded at the time this message was issued. If the scripts are incorrect, contact Compuware Customer Support.

SVPEXSVPEX100I LOAD MODULE xxxxxxxx ADDED TO EXIT LIST

Explanation: The module xxxxxxxx is now on the list of PIU exits.

User Response: Informational message. No user action necessary.

Page 246: Hiperstation Messages and Codes

5-58 Hiperstation Messages and Codes

SVRACSVRAC102I BUFFER SIZE CHOSE: xxxxxxxx NUMBER OF ENTRIES: yy

Explanation: The size of the buffer is xxxxxxxx with yy entries.

User Response: Informational message. No user action necessary.

SVRAC999E RACF IS NOT INSTALLED ON THIS SYSTEM

Explanation: The Global Recording Started Task did not detect RACF active on the current system.

System Action: The Global Recording Started Task terminates.

User Response: IF RACF is not your security package, check the value of the SECSYS parameter in the GRPARMS member your site is using. If RACF is your security package, contact Compuware Customer Support

SVSYSVSY100E VTAM LEVEL NOT SUPPORTED BY HIPERSTATION, LEVEL=vtam level

Explanation: This release of Hiperstation does not support the VTAM LEVEL you are using.

User Response: Check Hiperstation system requirements for currently supported VTAM levels; install compatible version of Hiperstation.

SVTSKSVTSK001I TASK xxxxxxxx WAS ATTACHED AT xx/xx/xx xx:xx:xx 000

Explanation: This is a time stamp indicating when task xxxxxxxx was attached.

User Response: Informational message. No user action necessary.

SVUSESVUSE005I USER-ID TRACKING READY FOR OPERATION

Explanation: This is an informational message indicating that user ID tracking has been initiated and is ready for use. This message is produced when the Global Record started task is brought up providing Global Record is set up to capture VTAM traffic.

SVUSE901I SHUTDOWN ACKNOWLEDGED

Explanation: This is an informational message indicating that the Global Record started task has acknowledged the shutdown command.

System Action: Begins processing shutdown.

SVXXSVXX104E HIPERSTATION SUBSYSTEM MUST BE RUNNING TO PERFORM THIS ACTION

Explanation: Your last action requires support from the Hiperstation address space. The address space is not currently running.

User Response: Start the Hiperstation address space.

Page 247: Hiperstation Messages and Codes

Hiperstation Messages: SCRTCP through SYSPLEX 5-59

SYSPLEXSYSPLEX-0348E Repository specifications <dataset_name> and <dataset_name> overlap.

Explanation: The indicated repository set specifications overlap. That is, they both include the one or more of the same repository segments.

System Action: Merging terminates.

User Response: Correct the dataset name, or the first or last values supplied on the REPIN DD statement.

SYSPLEX-0349E No timestamp in first dataset of specification <dataset_name>.

Explanation: The first segment in the indicated repository set does not contain a timestamp and therefore cannot be a valid Hiperstation repository.

System Action: Merging terminates.

User Response: Correct the repository set specification on the REPIN DD statement to include only valid Hiperstation repository datasets.

SYSPLEX-0350I Merging of repository sets is complete.

Explanation: Informational message

SYSPLEX-0351E No input repository sets were specified.

Explanation: There is no repository specification on the REPIN DD statement.

System Action: Merging terminates.

System Action: Provide minimally two repository specifications on the REPIN DD statement.

SYSPLEX-0352E REPIN file of input parameters could not be opened.

Explanation: The utility could not open the dataset specified on the REPIN DD statement.

System Action: Merging terminates.

User Response: Verify that the dataset name was specified correctly. If so, check to make sure that it is a fixed block dataset with an LRECL of 80. If the problem persists, contact Compuware Customer Support.

SYSPLEX-0353E No REPIN repository sets with expected protocol records found.

Explanation: None of the logical records contained in the datasets specified on the REPIN DD statement match the record selection parameter supplied on the SYSIN DD.

System Action: Merging terminates.

User Response: Ensure that the correct record selection parameter is specified for the type of repositories supplied on the REPIN DD. Record selection parameters include TCP, APPC, and MQ. If none of the record selection parameters are specified in the SYSIN DD, the merger uses the default value of MQ.

SYSPLEX-0354E Output repository segment <repository_segment> already exists.

Explanation: The merger was unable to allocate the indicated output dataset because it already exists.

System Action: Merging terminates to preserve the existing dataset.

User Response: Make sure that the REP_MERGE, FIRST, and LAST parameters do not result in a dataset name that already exists.

SYSPLEX-0355W Input repository segment <repository_segment> does not exist.

Explanation: The merge utility attempted to open the indicated input repository dataset, but that dataset does not exist.

System Action: The utility continues processing with the next segment in the repository set or the next dataset specified on the REPIN DD.

User Response: None.

Page 248: Hiperstation Messages and Codes

5-60 Hiperstation Messages and Codes

SYSPLEX-0356E Output repository set <repository_set> is full. Remaining REPIN records not merged.

Explanation: The merge utility has filled the indicated output dataset or range of datasets.

System Action: Remaining input repository records are not merged and merging terminates.

User Response: Specify a larger output repository by doing any or all of the following:

• Segment the repository — insert a wildcard character into the repository name specified on the SYSIN REPOSITORY parameter and add FIRST and LAST parameters.

• Increase the number of segments — modify the range specified by the FIRST and LAST SYSIN parameters.

• Increase the primary and secondary storage values (REP_PRI and REP_SEC).• Change the space units value specified on the REP_SPACE parameter from TRK to CYL.

SYSPLEX-0357E REP_SPACE value <value> not TRK or CYL.

Explanation: The space unit value specified on the REP_SPACE parameter is not valid.

System Action: Merging terminates.

User Response: Change the REP_SPACE value to TRK for tracks or CYL for cylinders.

Page 249: Hiperstation Messages and Codes

6-1

Chapter 6.

6Hiperstation Messages: TCPAR through VTCSUTIL Chap 6

The chapter explains messages with prefix TCPAR through prefix VTCSUTIL and, if applicable, provides response actions you can take to resolve the issue causing the message. Messages are listed in alpha-numeric order and grouped by prefix. Use the “Contents” to help you find the message information you need.

TCPARTCPAR-0101I DATASET FULL - dataset name

Explanation: A recording repository has been filled. If more repositories are available for the recording request the next repository will be allocated and opened. Message TCPAR102I will also be issued. If no more repositories are available for the recording request message TCPAR103W will be issued and recording will be stopped.

User Response: If insufficient data has been recorded, specify more and/or larger repositories in the recording request.

TCPAR-0102I NEXT DATASET - dataset name

Explanation: The next repository specified in the recording request is being allocated and opened.

User Response: Informational message. No user action necessary.

TCPAR-0103W RECORDING TERMINATED

Explanation: See the explanation for message TCPAR101I.

User Response: See the explanation for message TCPAR101I.

TCPAR-0104I CLOSING repository dataset

Explanation: The switch request is being processed. repository dataset has been closed.

User Response: Informational message. No user action necessary.

TCPAR-0105I NEXT SEGMENT - repository dataset

Explanation: The switch request is complete. repository dataset is now the active repository.

User Response: Informational message. No user action necessary.

TCPAR-0106I SWITCH COMPLETED RC: xxxx

Explanation:

User Response: Informational message. No user action necessary.

TCPAR-0200E I/O ERROR - dataset name

Explanation: An I/O error has been detected in a recording dataset. A second error message will follow that gives specific error information.

Code Description

0 Switch was successful.

4 Repository is closed. Switch was not attempted.

8 Switch failed.

Page 250: Hiperstation Messages and Codes

6-2 Hiperstation Messages and Codes

User Response: Correct the error specified in the message that follows this error message.

TCPAR-0201E I/O ERROR - DATASET IN USE

Explanation: The specified repository is already in use.

User Response: Specify a different dataset name in the recording request.

TCPAR-0202E I/O ERROR - NO SPACE

Explanation: Insufficient DASD space was available to allocate the repository.

User Response: Specify a smaller allocation for the repository or find more space.

TCPAR-0204E I/O ERROR - INVALID DATASET NAME

Explanation: An invalid dataset name was specified in the recording request.

User Response: Correct the dataset name in the recording request.

TCPAR-0205E I/O ERROR - INVALID BLOCK SIZE

Explanation: An invalid block size was specified for the repository.

User Response: Specify a valid block size for the repository.

TCPAR-0206E I/O ERROR - ACCESS DENIED BY SECURITY

Explanation: The installation’s security system has denied access to the repository.

User Response: You must specify the name of a repository that the Hiperstation started task address space has access to.

TCPAR-0207E ALL SEGMENTS FULL: repository dataset

Explanation: The segmented repository is full and wrap was not specified.

User Response: Informational message. No user action necessary.

TCPAR-0299E I/O ERROR - UNKNOWN

Explanation: An unknown I/O error has occurred in the specified repository.

User Response: Examine the system log for other messages to aid in determining the cause of the I/O error.

TCPAR-0310W NEXT REPOSITORY xxxxxxxxxxxxxxxx ALREADY EXISTS. NEXT CHANGE WILL FAIL

Explanation: When it's time to change to a new repository dataset, the name we will use already exists in the catalog. It must be deleted by that time or the repository change will fail. xxxxxxxxxxxxxxxx is the name of the dataset.

User Response: Delete the existing dataset before changing to the new repository dataset.

TCPAR-0320E REPOSITORY DSN xxxxxxxxxxxxxxx IS ALREADY IN CATALOG - REQUEST TERMINATED

Explanation: A dataset with the same name as the one we are trying to change to already exists in the catalog. The option is set to not delete this dataset. xxxxxxxxxxxxxxxx is the name of the dataset.

System Action: The request to change repository datasets fails.

User Response: Delete the existing dataset before changing to the new repository dataset.

TCPAR-0330E COULD NOT DELETE xxxxxxxxxxxxxxx

Explanation: A dataset with the same name as the one we are trying to change to already exists in the catalog. The attempt to delete it failed. xxxxxxxxxxxxxxxx is the name of the dataset.

System Action: The request to change repository datasets fails.

User Response: Delete the existing dataset before changing to the new repository dataset.

Page 251: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-3

TCPASYNCTCPASYNC-0184I Replay=nn Connection=nn Timeout for EVID=nn.

Explanation: During TCP playback read timeout occurred at EVID=nn.

User Response: Informational message. No user action necessary.

TCPCTCPC100A INVALID PANEL NUMBER

Explanation: An internal error has occurred while displaying the script creation panels.

User Response: Note the events surrounding this message and contact Compuware Customer Support.

TCPC100B DATASET NAME TOO LONG

Explanation: Full dataset name must be 44 characters or less.

User Response: Supply a dataset name that, with wildcards, is at most 44 characters in length.

TCPC100C MORE THAN ONE *

Explanation: Only one * is allowed in a dataset name.

User Response: When using the * wildcard, supply only one in a dataset name. Correct any dataset names with more than one *.

TCPC100D INVALID MIX OF * AND ?

Explanation: Either * or ? can appear, but not both.

User Response: When using wildcards, supply either a single * or one or more ?. Correct any dataset names that use * or ? incorrectly.

TCPC100E DSN NODE MUST BE 1-8

Explanation: Dataset name node length must be from 1 to 8 characters.

User Response: Supply a dataset name node that is at most 8 characters in length.

TCPC100F 1ST CHAR INVALID

Explanation: The 1st character in a dsn name or node must not be *?-, or 0-9.

User Response: Supply a dataset name node that starts with A-Z, @, #, or $.

TCPC100G INVALID CHARS IN DSN

Explanation: A dataset name must be A-Z, 0-9, or national characters.

User Response: Supply a dataset name that contains only A-Z, 0-9, @, #, and $.

TCPC100H NO GAPS BETWEEN ?

Explanation: No other characters allowed between ? characters.

User Response: Supply more than one ? wildcard character with no other characters between the ? characters.

TCPC100I FEBRUARY 29 NOT VALID

Explanation: February 29 is valid only for a leap year.

User Response: Change the day, month, or year to create a valid date.

TCPC100J BAD PROTOCOL

Explanation: Line llll: The valid protocols are: HTTP, HTTPS, CTG, DB2C, ECI, IMSC and TCP.

Page 252: Hiperstation Messages and Codes

6-4 Hiperstation Messages and Codes

User Response: Supply one of the indicated protocol values.

TCPC100K NO FILTERS PRESENT

Explanation: You must supply at least one TCP/IP filter line.

User Response: Supply at least one line in the scrollable area of the panel to act as a filter.

TCPC100L PORT MUST BE <=65535

Explanation: Filter# llll: The port number must be less than or equal to 65535.

User Response: Supply a port number from 0 through 65535.

TCPC100M PORT MUST BE A NUMBER

Explanation: Filter# llll: The port number must consist only of digits 0-9.

User Response: Supply a valid number for the port number field.

TCPC100N BAD URL SEGMENT LENGTH

Explanation: Filter# llll: A segment of an IP address must be one to three digits.

User Response: Supply a valid IP address with each segment ranging from 0 through 255.

TCPC100O BAD URL WILDCARDS

Explanation: Filter# llll: In an IP address, a single * must be alone in a segment.

User Response: Supply only a single * wildcard character in the IP address segment.

TCPC100P URL VALUE TOO LARGE

Explanation: Filter# llll: Each segment value of an IP address must be 255 or less.

User Response: Supply a valid IP address with each segment ranging from 0 through 255.

TCPC100Q EXTRA DATA IN URL

Explanation: Filter# llll: Extra data in IP address, must be nnn.nnn.nnn.nnn only.

User Response: Supply a valid IP address with exactly 4 segments.

TCPC100R INVALID URL CHARACTERS

Explanation: Filter# llll: An IP address must be digits, periods, and *.

User Response: Supply only the indicated characters in the IP address.

TCPC100S FIRST MUST BE LOWER

Explanation: The first number must be less than or equal to the last number.

User Response: When using wildcards in a repository dataset name, the range of numbers used to generate the final dataset names must be in low to high order.

TCPC100T DATASET PROBLEM

Explanation: Dataset dddd could not be accessed, SYSREASON(rrrr).

User Response: Ensure that the dataset is not already allocated by another user or batch job.

TCPC100U JCL CREATION PROBLEM

Explanation: Verify that LIBDEF ISPSLIB is correct in your Hiperstation CLIST.

User Response: If the TSO CLIST used to access the Hiperstation panels does not contain a LIBDEF statement for the name 'ISPSLIB', change the CLIST so that it does.

TCPC100V NO ROOM FOR VALUE

Explanation: First or last number is too large for indicated space in dataset name.

User Response: Supply first and last numbers for substitution into the repository dataset name that will fit within the space you have reserved with the wildcard characters.

Page 253: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-5

TCPC100W SUPPLY VALUES

Explanation: You must supply first and last numbers when you supply wildcards.

User Response: Since you have supplied wildcard characters in the repository dataset name, you must also supply numeric values that will be substituted into that name during script creation.

TCPC100X SUPPLY VALUE

Explanation: You must select at least one of: Log, Script, or Details.

User Response: Type a slash (/) next to one or more of the options on this panel.

TCPC100Y SUPPLY UNIQUE DSN/PREFIX

Explanation: Each dataset name and prefix combination must be unique.

User Response: Supply a member prefix with each dataset so that the combination of dataset name plus member prefix is not the same as any other line on the panel.

TCPC110D SQL Code not numeric

Explanation: The SQL Code must be numeric.

User Response: Supply a valid number for the SQL Code field.

TCPC110E Cannot Filter pppp

Explanation: No additional filtering is available for the protocol: pppp.

User Response: The selected protocol does not have any additional filtering available. If additional filtering is required for the combination of IP addresses and ports selected, change the Protocol Name on this filter to a protocol with additional filtering available

TCPC110F SQL Code invalid value

Explanation: The SQL Code must be between -32768 and 32767.

User Response: Supply an SQL code between the specified ranges.

TCPC110G RO invalid for numeric

Explanation: ‘ro’ is an invalid Relational Operator for numeric fields.

User Response: Contains (CO) and Not Contains (NC) cannot be used against a numeric field. Supply a different relational operator for this field.

TCPC110H SQL State invalid value

Explanation: SQL State must be five characters or end with a wild card.

User Response: Supply a complete SQL State value (five characters) or supply up to four characters plus the wild card character (asterisk).

TCPC110I SQL State invalid value

Explanation: Filter# llll: SQL State must be five characters or end with a wild card

User Response: Supply a complete SQL State value (five characters) or supply up to four characters plus the wild card character (asterisk) for the specified filter number.

TCPC110J Incorrect Hexadecimal

Explanation: Filter# llll: an even number of hexadecimal digits (0..9,A..F) must be specified.

User Response: Verify the hexadecimal value entered on the specified filter and correct as necessary.

TCPC110K Incorrect Hexadecimal

Explanation: An even number of hexadecimal digits (0..9,A..F) must be specified.

User Response: Verify the hexadecimal value and correct as necessary.

TCPC110L Review default ROs

Explanation: Some RO fields were assigned default values, verify assignments.

Page 254: Hiperstation Messages and Codes

6-6 Hiperstation Messages and Codes

User Response: Some filter criteria did not have relational operators specified and exit from the panel was requested. Default values have been provided for these relational operators. Verify that the defaulted values are correct before exiting the panel.

TCPCNCTNTCPCNCTN-0025E REPLAY=r CONNECTION=i CONNECT REQUEST FAILED TO SERVER =IP address PORT=port number (module)

Explanation: Hiperstation was unable to connect to the indicated server IP address and port for the indicated connection (i) on the indicated replay (r). The replay value indicates the thread of playback. It is a serial value, assigned by Hiperstation, that correlates to the start of replay for each SOCKETS.

System Action: Playback terminates for the specific connection.

User Response: Review the subsequent error messages to determine the cause of failure.

TCPCNCTN-0089I REPLAY=r CONNECTION/OBJECT=y WRITES=rwts READS=rds BYTES SENT=snt BYTES RECEIVED=rcvd

Explanation: Describes the input/output requests on the connection or queue as well as the volume of data exchanged.

User Response: Informational message. No user action necessary.

TCPCNCTN-0094I REPLAY=r CONNECTION=y DISCONNECTED

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPCNCTN-0120W REPLAY=r CONNECTION=cid I-O IN PROGRESS. DISCONNECT DELAYED.

Explanation: Informational message.

User Response: No user action necessary.

TCPCNCTN-0177W Replay=r Connection=i ECI(CPMI) playback without CCIN transaction.

Explanation: Playback failed for the indicated connection (i) and replay (r). Although Hiperstation was able to connect, playback failed due to a missing CCIN transaction.

System Action: Play back terminates for the specified connection.

User Response: Record the activity again to capture the CCIN transaction. While recording, cycle the CTG to ensure the CCIN transaction is captured.

TCPCNCTN-0179W Replay=r Connection=i terminated, DB2 Release mismatch - Expected=e Actual=a.

Explanation: Playback for the indicated connection (i) and replay (r) was stopped. Although Hiperstation was able to connect, playback terminated due to incompatible releases of DB2. (e) represents the DB2 release specified in the script and (a) represents the DB2 release used during the playback. The DB2 release can be indirectly altered by the DB2_RDBNAM parameter specified as an override in either the script or the playback control cards.

System Action: Playback terminates for the specified connection.

User Response: Ensure that the playback is done against the same release of DB2 specified in the script.

TCPCNNLSTCPCNNLS-0064E REPLAY=r UNABLE TO BUILD CONN_LIST CONTROL BLOCK

Explanation: Be sure that REGION=0M is specified on the EXEC card.

Page 255: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-7

TCPCNNLS-0065E REPLAY=r UNABLE TO BUILD CONNECTION CONTROL BLOCK

Explanation: Be sure that REGION=0M is specified on the EXEC card.

TCPIOTCPIO-0120I REPLAY=r CONNECTION/OBJECT=id I-O IN PROGRESS DISCONNECT DELAYED

Explanation: A request to close a queue or disconnect for a TCP/IP connection has been issued but there is an outstanding I-O on the connection/object. The disconnect request is postponed.

User Response: Informational message. No user action necessary.

TCPMSSGETCPMSSGE-0105E REPLAY=r CONNECTION=x MESSAGE TOO LARGE TO PROCESS.

Explanation: Hiperstation will process messages up to 256k.

User Response: If your messages are larger than 256k, contact Compuware Customer Support.

TCPMSSGE-0118E STORAGE REQUEST FAILED FOR len=%i

Explanation: A large message was being built but there is insufficient available storage to build the message. The playback is terminated.

User Response: Increase the storage available via the REGION parameter and re-run the playback.

TCPMSSGE-0119E STORAGE REQUEST FAILED FOR len=x

Explanation: The storage request failed for len=x.

User Response: Ensure that REGION=OM is specified on the EXEC card.

TCPPBCCTCPPBCC-0001E MULTIPLE CONTROL STATEMENTS FOUND

Explanation: Remove the extra CONTROL statements or place it as the first control card.

TCPPBCC-0002E SYNTAX ERRORS FOUND

User Response: Review the associated message and make the appropriate corrections.

TCPPBCC-0003E A SCRIPTSTATEMENT IS OUT OF SEQUENCE

User Response: Ensure that a SOCKETS or MQGROUP statement occurs prior to any SCRIPT statement.

TCPPBCC-0087I SKIPPING SCRIPT STATEMENT: %s... DUE TO PRIOR ERROR(S)

User Response: Correct the prior errors and retry the playback.

TCPPBCC-0255W COLLECT statement is invalid for a server playback

Explanation: Server playback does not support the collection of information into the database. The statement is ignored.

User Response: Remove the COLLECT statement from the control cards.

Page 256: Hiperstation Messages and Codes

6-8 Hiperstation Messages and Codes

TCPPBMNTCPPBMN-0004I PLAYBACK IS BEGINNING

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0005I EXAMINING CONTROL CARDS

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0006I PLAYBACK TERMINATED WITH sssssss

Explanation: sssssss can be either “warning” or “error”. A warning is an informative statement; it does not stop the job from running. An error means that the job will not run until the error is corrected.

User Response: Review prior messages to determine the type of warning or error, and correct.

TCPPBMN-0007E MAXIMUM RETURN CODE=xx

Explanation: The playback ended with return code xx.

User Response: For non-zero return codes, see the accompanying warnings or error messages.

TCPPBMN-0008I TCP/IP PLAYBACK COMPLETED SUCCESSFULLY

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0009I READING CONTROL CARDS (SYSIN)

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0010I SCANNING RECORD: control card

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0011I BEGINNING PLAY

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBMN-0053E EXPECTED CONTINUATION FOR CONTROL CARD=statement_text NOT FOUND

User Response: Correct the error and re-run the playback.

TCPPBMN-0096E SYSIN FILE OPEN FAILURE - PLAYBACK TERMINATED.

Explanation: The playback will normally terminate with condition code 3000 when this error occurs.

Code Description

xx=0 No errors detected.

xx=4 Playback completed with warnings or errors which applied to a single connection or replay, not the full playback.

xx=8 Playback terminated with errors which affected the full playback. Usually these errors are due to invalid control cards.

xx=12The playback could not continue and the actions necessary to correct the errors are beyond the scope of the individual playback. Usually this return code is the result of attempting to run the playback from a library that does not have APF authorization.

Page 257: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-9

User Response: Include a SYSIN file. If using a PDS a valid member name must be included.

TCPPBMN-0104E PLAYBACK TERMINATED - TCPPBMN MUST RUN FROM AN AUTHORIZED LIBRARY

Explanation: TCP/IP or WebSphere MQ playback was terminated because the Hiperstation load library was not APF authorized.

User Response: Authorize the Hiperstation load library. Refer to the Hiperstation Installation and Configuration Guide.

TCPPBMN-0114I TCP/IP RESOURCE LIMIT 9rlimit0 VALUES ARE: (curr max). ERRNO: err.

Explanation: Hiperstation could not increase the number of simultaneous sockets that it can open.

User Response: Informational message. No user action necessary.

TCPPBMN-0212E No OMVS Available.

Explanation: No OMVS segment was found.

User Response: Define a RACF OMVS segment. See your MVS administrator.

TCPPBMN-0218E ERRORLOG DD required.

Explanation: Your playback job is missing the ERRORLOG DD statement.

User Response: Add an ERRORLOG DD statement to you playback JCL before the Playback Log SYSOUT DD. Refer to the Hiperstation for WebSphere MQ User Guide for more details.

TCPPBMN-0219E Error opening ERRORLOG DD.

Explanation: There was an error while opening the ERRORLOG DD.

User Response: Make sure the output described by the DD is available to the program.

TCPPBMN-0220E Invalid HFS file specification. (HTM/HTML)

Explanation: The program was unable to open the HFS file specified.

User Response: Make sure the specified file has an .htm or .html extension and that the HFS path is valid.

TCPPBMN-0221E Unable to create HFS directory.

Explanation: The program was unable to create the HFS directory.

User Response: Make sure you have access to an OMVS segment and permission to create files and directories there. See your MVS administrator.

TCPPBMN -0250W <parameter> option is invalid on <statement> for a <type> playback

Explanation: The <parameter> parameter specified on the Hiperstation for Mainframe Servers playback statement <statement> is not valid for a <type> playback.

• <parameter> is a client or server playback specific option.• <statement> indicates which statement in the control cards this error was found. If the

error is on the CONTROL statement, <statement> will be “the CONTROL statement”. If the error is on a SOCKETS statement, <statement> will be “SOCKETS statement=n”, where n indicates which SOCKETS statement is in error. If the error is on a SCRIPT statement, <statement> will be “SOCKETS statement=m SCRIPT statement=n” where m indicates which SOCKETS statement and n indicates which SCRIPT statement under the SOCKETS statement.

• <type> is either “client” or “server”.

User Response: Change the Hiperstation for Mainframe Servers playback statement so that the parameter specified is appropriate for the type of playback being done (either client playback or server playback) or change the type of playback being done.

Page 258: Hiperstation Messages and Codes

6-10 Hiperstation Messages and Codes

TCPPBPLYTCPPBPLY-0061E UNEXPECTED CONTROL CARD FOUND: xxxxxxxxxxxxxx

User Response: Be sure that there is a valid CONTROL statement in the control card deck. Remove the statement in error.

TCPPBPLY-0083E INVALID STATEMENT FOUND: ssssssss

User Response: Correct the control card.

TCPPBPLY-0084E REPLAY=r IO FAILURE FOR CONNECTION=y AFTER n RETRIES

Explanation: The TCP request was attempted n times.

TCPPBPLY-0208E NO SCRIPT GROUPS (SOCKETS OR MQGROUP) FOUND TO PLAYBACK

Explanation: No valid SOCKETS/MQGROUP are found to playback.

User Response: Define the appropriate MQGROUP and/or SOCKETS and retry the playback.

TCPPBPLY-0252E OFFLINE and PLAY(SERVER) are ambiguous options on the CONTROL statement.

Explanation: An offline playback is used to create a reporting database while server playback does not support reporting. Therefore, these two options are not compatible.

User Response: Either remove OFFLINE or PLAY(SERVER) from the CONTROL statement.

TCPPBRC1TCPPBRC1-0176E Invalid Keyword in COLLECT Statement

Explanation: The statement being parsed contains an invalid keyword.

System Action: Playback terminates with return code of 8.

User Response: Review the next TCPPBUTL-0052I message to identify which COLLECT statement is in error. Correct the statement and resubmit the job. Refer to the user guide for more information on Playback and Reporting statements.

TCPPBPRTTCPPBPRT-0013E PLAYBACK INIT ERROR

Explanation: This error can occur if PARM=POSIX(ON)/ is specified on the EXEC card or if REGION=0M is not specified on the EXEC card.

User Response: Ensure that REGION=0M.

TCPPBPRT-0016E ERROR LOADING SCRIPTS FOR SOCKETS/MQGROUP=n

Explanation: The scripts for the indicated SOCKETS/MQGROUP statement (n) could not be loaded into the cache. Hiperstation assigns a serial value n to the SOCKETS/MQGROUP statements for identification purposes.

User Response: Ensure that REGION=0M.

TCPPBPRT-0018I PROCESSING COMPLETE FOR SOCKETS/MQGROUP=n

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBPRT-0019I SETTING UP ACCESS TO SCRIPTS

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

Page 259: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-11

TCPPBPRT-0020E ERROR LOADING SCRIPTS FOR SOCKETS STATEMENT=n

Explanation: An error occurred while loading scripts for SOCKETS statement=n.

User Response: Correct the associated errors and retry the playback. Be sure that PARM=POSIX(ON)/” is NOT specified, and that REGION=0M is specified on the EXEC card.

TCPPBPRT-0056E UNABLE TO START PLAYBACK. REASON CODE=rc

Explanation: This error may be caused by “PARM=POSIX(ON)/” is specified on the EXEC card, or because REGION=0M is not specified on the EXEC card.

User Response: Ensure that REGION=0M.

TCPPBPRT-0057E REXX INITIALIZATION FAILED. REXX HAS BEEN TURNED OFF FOR THIS PLAYBACK.

Explanation: REXX initialization has failed.

User Response: Review earlier error messages for information about REXX initialization.

TCPPBPRT-0119E SSL INITIALIZATION FAILED RETURN CODE: rc

Explanation: A playback requiring SSL was requested but the SSL initialization failed.

User Response: Ensure the SSLINFO DD statement is in the playback PROC and points to the dataset containing the key information. See your installer if the statement is missing or points to DUMMY. You may also want the installer to verify that the information within the dataset is set up properly. If you receive a return code of:

– 4, verify that the SSLINFO dataset is fixed block.

– 11, ensure that access to the SSLINFO dataset is granted to the user.

– 15, ensure that the server is using a standard signing authority. If the server is using a self-signed certificate, ensure that it is imported into the Hiperstation for Mainframe Servers keyring database.

TCPPBPRT-0123E YOUR SYSTEM CANNOT SUPPORT THIS PLAYBACK REQUESTED TASKS: rt MAXIMUM TASKS: mt

Explanation: The number of SOCKETS/MQGROUP statements (including COUNT parameters) is larger than the system can support.

User Response: Increase the OMVS max tasks and max threads or reduce the size of the playback.

TCPPBPRT-0124E INSUFFICIENT RESOURCES AVAILABLE TO SUPPORT THIS PLAYBACK

Explanation: There is insufficient storage to start the number of SOCKETS/MQGROUPs requested (including the COUNT parameter).

User Response: Reduce the size of the playback (increasing the size of the REGION size will normally have no effect).

Code Description

rc 1 Insufficient storage or invalid request for storage.

rc 2 Insufficient storage to set up signalling process.

rc 3 Insufficient storage to set up dispatching process.

rc 4 Insufficient storage to set up serialization processing.

rc 5 Insufficient storage to set up locking processing.

rc 6 Insufficient storage to set up SOCKETS/MQGROUP termination processing.

Page 260: Hiperstation Messages and Codes

6-12 Hiperstation Messages and Codes

TCPPBRPTTCPPBRPT-0001I SCANNING RECORD:...input statement...

System Action: Displays each input statement - message contents are the input statement.

User Response: Informational message. No user action necessary.

TCPPBRPT-0002E STATEMENT #nnnn MUST BEGIN WITH ‘CONTROL’ OR ‘REPORT’, BEGINS WITH: xxxxxxxxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0003E UNABLE TO OPEN SYSIN

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0004E STATEMENT #nnnn INVALID PARAMETER WITHIN ‘CONTROL’ STATEMENT: xxxxxxxxxxxx

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0005E ‘DATABASE’ MUST BE A VALID DDNAME

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0006E ‘LAYOUT’ MUST BE EITHER TABLE OR FORM

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0007E ‘TYPE’ MUST BE EITHER TEXT OR HTML

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0008E STATEMENT #nnnn INVALID PARAMETER WITHIN ‘REPORT’ STATEMENT: xxxxxxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0009E SYNTAX ERROR WITHIN ‘FIELDS’ PARAMETER

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0010E SYNTAX ERROR WITHIN ‘WHERE’ PARAMETER

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0011E SYNTAX ERROR WITHIN ‘FROM’ PARAMETER

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

Page 261: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-13

TCPPBRPT-0012E ‘INTO’ MUST BE A VALID DDNAME

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0013E FROM PARAMETER IS MISSING - REQUIRED

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0014E FIELDS PARAMETER IS MISSING - REQUIRED

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0015E REPORT STATEMENT #nnnn BYPASSED DUE TO ERROR NOTED ABOVE

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0016E CONTROL STATEMENT #nnnn BYPASSED DUE TO ERROR NOTED ABOVE

System Action: Program execution terminates.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0017I CONTROL STATEMENT #nnnn ACCEPTED

Explanation: Informational message.

User Response: No user action necessary.

TCPPBRPT-0018I REPORT STATEMENT #nnnn ACCEPTED

Explanation: Informational message.

User Response: No user action necessary.

TCPPBRPT-0019I REPORT STATEMENT #nnnn PROCESSING COMPLETED

Explanation: Informational message.

User Response: No user action necessary.

TCPPBRPT-0020E NOT A VALID FIELD NAME FOR THIS TABLE: xxxxxxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0021E CANNOT DO AVGxx ON THIS FIELD, THIS TABLE: xxxxxxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0022E REPORT STATEMENT #nnnn ERROR OPENING ‘INTO’ DDNAME: xxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0023E REPORT STATEMENT #nnnn ERROR OPENING INPUT DDNAME: xxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

Page 262: Hiperstation Messages and Codes

6-14 Hiperstation Messages and Codes

User Response: Correct the error and resubmit the job.

TCPPBRPT-0024E NO FIELD SELECTED (OR DERIVED) TO REPORT

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0025E TOO MANY FIELDS FOR TABLE FORMAT. ONLY THE FIRST nn FIELDS WILL BE PRINTED.

System Action: Reporting continues. Fields beyond the maximum number do not appear in the report.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0026E REPORT STATEMENT #nnnn TABLE NAME NOT RECOGNIZED: xxxxxxxxxxxx

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0027E REPORT STATEMENT #nnnn MULTIPLE ‘FROM’ PARAMETERS ARE INVALID

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0028I CONTROL STATEMENT #nnnn PROCESSING COMPLETED

User Response: Informational message. No user action necessary.

TCPPBRPT-0029E ALLOCATION OF TEMPORARY DATASET FAILED. THIS REPORT TERMINATED.

System Action: Hiperstation could not dynamically allocate a temporary dataset to hold large-field (such as Response Body) data. APPC temporary dataset allocation parameters from EHSDFLT are used for volume and space.

User Response: Notify your MVS Systems Administrator. Allocation can fail if insufficient space exists. Review the EHSDFLT entry for APPC temporary datasets to determine which volume will be used and how much space will be allocated fro each temporary dataset. Adjust as necessary, then assemble and link-edit EHSDFLT. When that is complete, resubmit job.

TCPPBRPT-0030E LOGIC ERROR - DATA IN CORE, BUT MORE DATA HAS ARRIVED. THIS REPORT TERMINATED.

System Action: REPORT in progress terminates. Processing continues with the next statement, if any.

User Response: This is an internal logic error. Contact Compuware Customer Support. Include all control statements and a copy of the SORTED INPUT DATA with your problem documentation.

TCPPBRPT-0031E ‘BREAK’ MUST BE EITHER EJECT OR NEXT

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0032E ‘MAXLINES’ MUST BE NUMERIC, BETWEEN 30 AND 9999

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

TCPPBRPT-0033E DD STATEMENT xxxxxxxx DOES NOT CONTAIN A VALID PATHNAME

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Correct the error and resubmit the job.

Page 263: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-15

TCPPBRPT-0034E DD STATEMENT xxxxxxxx DYNALLOC FOR PATH INFORMATION FAILED

System Action: Hiperstation could not dynamically obtain PATH information.

User Response: Notify your MVS Systems Administrator. The most likely reason for this error is a conflict with a security product. Correct this error and resubmit the job.

TCPPBRPT-0035E DD STATEMENT xxxxxxxx CANNOT FIND END OF DIRECTORIES IN PATH

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

User Response: Your DD statement’s PATH parameter has an invalid syntax. Correct error and resubmit job.

TCPPBRPT-0036E DD STATEMENT xxxxxxxx NOT ENOUGH ROOM TO PLACE FILENAME IN PATHNAME

System Action: Hiperstation bypasses the statement in error. Processing continues with the next statement, if any.

Explanation: Your DD statement PATH contains over 247 bytes of directories. The maximum length for a PATH name is 256. You have specified a LINK in your REPORT statement. Hiperstation requires 8 positions for a dynamically-created filename.

User Response: Insufficient positions remain. Shorten your PATH or remove the specified LINKs and resubmit the job.

TCPPBRPT-0037E DD STATEMENT xxxxxxxx DYNALLOC FOR LINK FAILED. R15=nnnn ERROR= nnnn ERROR2=nnnn

System Action: Hiperstation could not dynamically allocate a PATH.

User Response: Notify your MVS Systems Administrator. The most likely reason for this error is a conflict with a security product. Insufficient space is another possibility. Correct this error and resubmit the job.

TCPPBRPT-0038E STATEMENT xxxxxxxx OPEN FOR LINKED FIELD FAILED

System Action: Hiperstation could not OPEN a dynamically-allocated PATH.

User Response: Notify your MVS Systems Administrator. The most likely reason for this error is a conflict with a security product. Correct this error and resubmit the job.

TCPPBRPT-0039E DD STATEMENT xxxxxxxx ALL LINKED FIELD NAMES USED UP - DELETE SOME!

Explanation: For each LINK, Hiperstation creates a unique filename. The names are constructed with four lower-case English letters, a dot, and a three position file type. Using this formula, over 500,000 unique names are possible (26x26x26x26). To receive this error message, all 500,000+ unique names have been tried and found to already exist.

System Action: Hiperstation could not dynamically allocate a PATH for a LINK field.

User Response: Delete some of these named files, then resubmit the job.

TCPPBRPT-0040I This abend is likely caused by incorrect or missing parameters on the DD card

TCPPBRPT-0041I for the PATH, PATHOPTS, and/or PATHMODE keywords.

Explanation: TCPPBRPT041I is a continuation of TCPPRPT040I. This message further explains a previous message (one of the following: TCPPBRPT022, TCPPBRPT029, TCPPBRPT034, TCPPBRPT037, or TCPPBRPT038).

TCPPBRPT-0042I Consult IBM doc for further information about this abend on OS/390 HFS datasets.

Explanation: This message further explains a previous message (one of the following: TCPPBRPT022, TCPPBRPT029, TCPPBRPT034, TCPPBRPT037, or TCPPBRPT038).

TCPPBRPT-0043I Notify Compuware Support. Include the JCL with the documentation.

Explanation: This message further explains a previous message (one of the following: TCPPBRPT022, TCPPBRPT029, TCPPBRPT034, TCPPBRPT037, or TCPPBRPT038).

Page 264: Hiperstation Messages and Codes

6-16 Hiperstation Messages and Codes

TCPPBRPT-0044I Your corporate SECURITY product has denied us access to the OS/390 HFS dataset.

Explanation: This message further explains a previous message (one of the following: TCPPBRPT022, TCPPBRPT029, TCPPBRPT034, TCPPBRPT037, or TCPPBRPT038).

TCPPBRPT-0045I Contact your Security Administrator

Explanation: This message further explains a previous message (one of the following: TCPPBRPT022, TCPPBRPT029, TCPPBRPT034, TCPPBRPT037, or TCPPBRPT038).

TCPPBRPT-0046E START VALUE WITHIN SUBSTR MUST BE NUMERIC

Explanation: The SUBSTR build-in function format is SUBSTR(field name, start, length). The start value is required, and must be numeric. Hiperstation detected a non-numeric start value.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0047E LENGTH VALUE WITHIN SUBSTR MUST BE NUMERIC

Explanation: The SUBSTR build-in function format is SUBSTR(field name, start, length). The length value is optional, and when present must be numeric. Hiperstation detected a non-numeric start value.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0048E INVALID BUILT-IN FUNCTION WITHIN LINK OR DIFF

Explanation: Built-in functions AVG, MIN, MAX, SUM, and COUNT cannot be used within LINK or DIFFERENCE clauses; only built-in function SUBSTR can be used within LINK and DIFFERENCE. One of the invalid built-in functions was detected.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0049E INVALID DDNAME

Explanation: A qualified field name was detected(ddname.fieldname), however, the ddname does not conform to MVS standards. Either it is too long (MVS allows a maximum of 8 characters), or it begins with a number.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0050E LINK BUILT-IN FUNCTION IS INVALID AT THIS TIME

Explanation: The LINK built-in function can be specified only within a FIELDS clause (not within another LINK or DIFFERENCE function) when the reporting type is HTML (not TEXT). LINK has been detected at an invalid point in time.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0051E DIFFERENCE BUILT-IN FUNCTION IS INVALID AT THIS TIME

Explanation: The DIFFERENCE built-in function can be specified only within a FIELDS clause (not within another LINK or DIFFERENCE function) when the reporting type is HTML (not TEXT). DIFFERENCE has been detected at an invalid point in time.

System Action: The entire REPORT statement is bypassed.

User Response: Correct and rerun.

TCPPBRPT-0052E BUT NOT A CHARACTER-TYPE FIELD

Explanation: The SUBSTR built-in function is not valid in conjunction with fields that are timestamps, return codes, status codes, lengths, and counts. It is valid only with character-based fields such as response header and response body.

System Action: The entire REPORT statement is bypassed.

Page 265: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-17

User Response: Correct and rerun.

TCPPBRPT-0053E REPORT STATEMENT #nnnn ‘INTO’ DDNAME dddddddd IS A LIBRARY - NO MEMBERNAME PROVIDED

Explanation: On a REPORT statement, the user provided a (required) ddname via the INTO parameter. The file type of this dataset was a library (PDS or PDSE). However the dataset name provided did not also contain a member name, so Hiperstation could not open this DD for output without destroying the entire library contents.

User Response: Change the DSN JCL parameter, either by adding a member name after the existing DSN or by changing the DSN to that of a non-library dataset.

TCPPBRPT-0054E LITERAL VALUE IN ‘WHERE’ PARAMETER IS INVALID FOR xxxxxxxxxxxxxxxxxxxx

Explanation: During validation of a REPORT statement WHERE clause, the field on the left side was determined to be one with specific valid values. However the value on the right side of the WHERE clause was not one of those specific valid values.

User Response: Correct the statement and resubmit the job.

TCPPBRPT-0055E ‘FIELDDEPTH’ MUST BE A NUMERIC, BETWEEN 1 AND 99

Explanation: During validation of a CONTROL statement FIELDDEPTH clause, either a syntax error was found (no closing parenthesis), a non-numeric value was found, or the numeric value found was out of the acceptable range (1-9999).

User Response: Correct the statement and resubmit the job.

TCPPBRPT-0056E FILE OPEN ERROR - DDN: ddname

Explanation: The dataset specified by DDNAME in the JCL cannot be opened.

User Response: Ensure that there is a valid value for DDNAME in the JCL.

TCPPBRPT-0057E SYNTAX ERRORS FOUND

User Response: Correct the syntax errors and retry.

TCPPBRPT-0058E EXPECTED CONTINUATION FOR CONTROL CARD=xxxxxxxx NOT FOUND

Explanation: Can occur when the last card in the control input stream contains a continuation symbol (-) or no control cards are supplied. xxxxxxxx is the last control card image.

User Response: Ensure that the last control card does not end with a continuation symbol and that valid control cards are specified.

TCPPBRPT-0059E STORAGE REQUEST INVALID FOR len=nnnnnnnn (>256k)

User Response: Correct the storage request and retry.

TCPPBRPT-0060W STORAGE LEAKS DETECTED FOR xxxxxxxx at=xxxxxxxx REMAINING STORAGE AREAS=nnnnnnnn

Explanation: Used in debugging.

User Response: Contact Compuware Customer Support.

TCPPBRPT-0061E PLAYBACK REPORT JOB TERMINATED WITH ERRORS

Explanation: The report job has ended with an error documented in other error messages.

User Response: Review the other error messages.

TCPPBRPT-0062E MAXIMUM RETURN CODE=nnnn

Explanation: The return code associated with previous error message.

User Response: Informational message. No user action necessary.

TCPPBRPT-0063I TCP/IP REPORTING COMPLETED SUCCESSFULLY

Explanation: Informational.

User Response: Informational message. No user action necessary.

Page 266: Hiperstation Messages and Codes

6-18 Hiperstation Messages and Codes

TCPPBRPT-0064I READING CONTROL CARDS (SYSIN)

Explanation: Informational.

User Response: Informational message. No user action necessary.

TCPPBRPT-0065E INVALID TOKEN FOUND: xxxxxxxx

User Response: Correct the invalid token and retry.

TCPPBRPT-0066E INVALID STATEMENT FOUND: xxxxxxxx

User Response: Correct the invalid statement and retry.

TCPPBRPT-0068E REPORT DATABASET HAS NOT BEEN SORTED FOR DDNAME:ddname

User Response: Sort the database using program TCPPBSRT.

TCPPBRPT-0069E 'STOPON' must be numeric, between 1 and 9999

Explanation: The value specified for the STOPON parameter of the REPORT COMPARE statement was not between 1 and 9999.

User Response: Change the value to a number between 1 and 9999 and re-run reporting job.

TCPPBRPT-0070E 'BASELINE' must be a valid DDNAME

Explanation: An invalid DD name was specified on the BASELINE parameter of the REPORT COMPARE statement.

User Response: Change the value to a valid DD name and re-run reporting job. Refer to IBM’s documentation for DD name specifications.

TCPPBRPT-0071E Error(s) occurred while processing masking statements

Explanation: One or more errors occurred while processing the masking statements that are located in the dataset specified on the MASK parameter of the REPORT COMPARE statement. All errors are listed before this message.

User Response: Examine previous errors in the job output, correct the errors, and re-run the reporting job.

TCPPBRPT-0072E Keyword <keyword> cannot be specified because it is incompatible with a previous keyword

Explanation: Mutually exclusive keywords were specified on the REPORT statement. The message indicates the offending keyword where <keyword> is shown.

User Response: Correct the REPORT statement and re-run the reporting job.

TCPPBRPT-0073E Unable to determine report type

Explanation: Hiperstation determines whether the database that is specified contains TCP/IP or WebSphere MQ data for basic reporting. The data collected in the database does not provide adequate information to make this determination.

User Response: Re-run the playback with COLLECT statements that collect all available information. Consult either the Hiperstation for Mainframe Servers User Guide or Hiperstation for WebSphere MQ User Guide.

TCPPBRPT-0074E Field <field name> in <ddname> was not collected and is required for this report

Explanation: <field name> was not found in either the database or baseline database and is required for this report.

User Response: Re-run the playback with COLLECT statements that collect all available information. Consult either the Hiperstation for Mainframe Servers User Guide or Hiperstation for WebSphere MQ User Guide.

TCPPBRPT-0075E Missing <relational operator | compare value | position> parameter on WHEN clause (<when-clause>)

Explanation: The WHEN clause in the masking dataset has three required fields - position, relational operator, or compare value. The error indicates the missing field.

Page 267: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-19

User Response: Correct the WHEN clause in the masking statement to include the specified field and re-run the reporting job.

TCPPBRPT-0076E Non-numeric position (<position>) in WHEN clause

Explanation: The value <position> contains one or more non-numeric characters.

User Response: Correct the WHEN clause in the masking statement with a numeric value for position and re-run the reporting job.

TCPPBRPT-0077E Invalid relational operator (<rel-op>) on WHEN clause

Explanation: <rel-op> is not a valid relational operator.

User Response: Correct the WHEN clause in the masking statement with a valid relational operator and re-run the reporting job. Refer to either the Hiperstation for Mainframe Servers User Guide or the Hiperstation for WebSphere MQ User Guide for a list of valid relational operators.

TCPPBRPT-0078E Invalid single quote in position <position> found in compare value C'<compare value>

Explanation: Standalone single quotes are not valid for a character compare value. In order to include a single quote as part of the compare value string it should be followed immediately by another single quote. Together, both single quotes are treated as one single quote.

User Response: Correct the WHEN clause in the masking statement with a valid compare value and re-run the reporting job.

TCPPBRPT-0079E Missing <WHEN | MASK> clause from masking statement

Explanation: Masking statement is missing the WHEN or MASK clause.

User Response: Correct the masking statement to contain both the WHEN and MASK clauses and re-run the reporting job.

TCPPBRPT-0080E Only one <WHEN | MASK> clause can be on a single masking statement

Explanation: Masking statement has more than one WHEN or MASK clause.

User Response: Remove one of the WHEN or MASK clauses from the masking statement and re-run the reporting job.

TCPPBRPT-0081E Non-numeric <position | length> (<number>) specified in the <WHEN | MASK> clause

Explanation: The WHEN or MASK clause contains a position or length value (<number>) with one or more non-numeric characters.

User Response: Correct the position or length in the WHEN or MASK clause and re-run the reporting job.

TCPPBRPT-0082E Position <position> contains an invalid <binary | packed decimal | hexadecimal> character in compare value <M | P | X>'<value>'

Explanation: The WHEN clause of the masking statement specifies an invalid masked, packed decimal, or hexadecimal <value> at the specified position.

User Response: Correct the compare value in the WHEN clause of the masking statement and re-run the reporting job.

TCPPBRPT-0083E <M | P | X>'<value>' contains an invalid number of characters for a <masked | packed decimal | hexadecimal> value in the WHEN clause

Explanation: The compare value specified in the WHEN clause of the masking statement is not the correct length for the type of data it represents. Masked values contain only eight binary characters, Packed decimal values must be less than 32 characters, and hexadecimal values must contain an even number of characters.

User Response: Correct the compare value in the WHEN clause of the masking statement and re-run the reporting job.

TCPPBRPT-0084E Missing starting or ending single quote in <compare-value>

Explanation: The compare value on the WHEN clause of the masking statement must begin and end with a single quote.

Page 268: Hiperstation Messages and Codes

6-20 Hiperstation Messages and Codes

User Response: Correct the compare value in the WHEN clause of the masking statement and re-run the reporting job.

TCPPBRPT-0085E Invalid position:length entry (pos-len) specified in the MASK clause

Explanation: An entry in the MASK clause is missing a position, a length, or the separating colon.

User Response: Correct the masking position:length entry in the MASK clause of the masking statement and re-run the reporting job.

TCPPBRPT-0086E <rel-op> is not a valid relational operator for a <character | hexadecimal | masked | packed decimal> compare value

Explanation: The relational operator <rel-op> specified is not valid for the specified compare value type.

User Response: Correct the WHEN clause in the masking statement with a valid relational operator for the compare value type and re-run the reporting job. Refer to either the Hiperstation for Mainframe Servers User Guide or the Hiperstation for WebSphere MQ User Guide for a list of valid relational operators.

TCPPBRPT-0087E Invalid data in position <position> in compare value (<compare-value>)

Explanation: The compare value contains a standalone single quote in the middle of the compare value.

User Response: Remove the single quote from the compare value in the WHEN clause of the masking statement and re-run the reporting job.

TCPPBRPT-0088E Missing position:length parameter in MASK clause

Explanation: The MASK clause either ends with a comma or contains two consecutive commas.

User Response: Delete the additional comma and re-run the reporting job.

TCPPBRPT-0089I Reading of masking statements from DDName <ddname> initiated

Explanation: Informational message to indicate that the masking statements are being read from <ddname>.

TCPPBRPT-0090I Reading of masking statements from DDName <ddname> completed

Explanation: Informational message to indicate that the masking statements are done being read from <ddname>.

TCPPBRPT-0091I STOPON limit (<mismatch-limit>) reached - subsequent mismatches will not be reported

Explanation: The STOPON parameter value specified on the REPORT COMPARE statement was met.

System Action: Hiperstation stops reporting.

User Response: If you wish to report more exceptions, increase the STOPON value and re-run the reporting job.

TCPPBRPT-0092E Unable to allocate HFS file: <file>

Explanation: The allocation of HFS file <file> failed.

User Response: Check preceding messages for a description of the problem with the allocation.

TCPPBRPT-0093E Unable to open HFS file <file> on DDName <ddname>

Explanation: The opening of HFS file <file> on <ddname> failed.

User Response: Check preceding messages for a description of the problem with the open.

TCPPBRPT-0094E Invalid single quote in position nn found in TITLE argument (aaa)

Explanation: A single apostrophe was found within the title argument. nn indicates the position of invalid data and aaa is the title on the report statement.

Page 269: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-21

System Action: The report is not produced and processing continues for the next report statement in the reporting member.

User Response: To produce a title containing an apostrophe, the argument must have two consecutive apostrophes specified. Correct the TITLE argument and re-run the reporting job.

TCPPBRPT-0095E Invalid data at position nn in TITLE argument (aaa)

Explanation: An invalid character was found in the title. nn indicates the position of invalid data and aaa is the title on the report statement.

System Action: The report is not produced and processing continues for the next report statement in the reporting member.

User Response: Correct the TITLE argument and re-run the reporting step.

TCPPBRPT-0096I TITLE length must be 1 to 80 characters, keyword ignored.

Explanation: The title specified was either too long or too sort.

System Action: The report is produced using the default title.

User Response: Specify a valid character string for the TITLE keyword and re-run the reporting step to produce a report with the desired title.

TCPPBRPT-0097I <m> mismatches were found, <n> messages compared

Explanation: There were <m> exceptions to report. <n> indicates the number of messages that were compared.

TCPPBRPT-0098I <n> messages were bypassed

Explanation: Indicates that <n> messages from either the database or a baseline database were not compared because their was nothing to compare the message against.

User Response: Refer to message TCPPBRPT-0099I in the report creation job output to find out which messages were bypassed.

TCPPBRPT-0099I Message for <GROUP | SOCKET>=<socket #> SCRIPT=<script #> <CONNECTION | MESSAGESET>=<connection #> MESSAGE=<message #> from <ddname> bypassed

Explanation: Indicates that the given message from <ddname> was not compared because there was no corresponding message to compare against. <socket #> indicates the SOCKET (TCP/IP) or GROUP (WebSphere MQ) containing the bypassed message. <script #> indicates the script containing the bypassed message. <connection #> indicates the CONNECTION (TCP/IP) or MESSAGESET (WebSphere MQ) of the bypassed message. <message #> indicates the number of bypassed message.

User Response: Run a MESSAGE or MQMESSAGE report for the database; and if applicable, run one for the baseline database to see which messages are being bypassed.

TCPPBPRT-0100E Database and baseline database are not the same

Explanation: The database and baseline are of different types. This indicates that one database is for TCP/IP data and the other is for WebSphere MQ data. This data cannot be compared.

User Response: Re-run the job with a different database or baseline database and ensure that they are of the same type.

TCPPBRPT-0101E '<type>' is an invalid compare value type

Explanation: The mask command contains an invalid data type. Valid values are 'C' - Character, 'P' - Packed Decimal, 'M' - Masked, and 'X' - Hexadecimal.

User Response: Changed the compare value type to a valid type and re-run the reporting job.

TCPPBRPT-0102E Report type CSV is unavailable for Script Timing reports

Explanation: A RESPONSETIME or SCRIPTTIME report was requested in CSV format. CSV format is not supported for these basic reports.

User Response: Specify either HTML or TEXT format on the REPORT or reporting CONTROL statement.

Page 270: Hiperstation Messages and Codes

6-22 Hiperstation Messages and Codes

TCPPBRPT-0103E Required data from aaa table not found.

Explanation: A RESPONSETIME or SCRIPTTIME report was requested but required data from table aaa is not in the database.

User Response: Re-run the playback with COLLECT statements that collect all available information. Consult either the Hiperstation for Mainframe Servers User Guide or Hiperstation for WebSphere MQ User Guide.

TCPPBSTTCPPBST-0021E UNABLE TO PLAY STATEMENT: statement_text DUE TO PRIOR ERRORS

Explanation: Previous errors made it impossible to play the specified statement.

User Response: Correct associated errors and retry.

TCPPBST-0022I ERRORS FOUND IN STATEMENT statement_nbr RETURN CODE=rc

Explanation: The SOCKETS or MQGROUP statement identified by statement_nbr did not pass the syntax check. Hiperstation assigns a statement_nbr sequentially to the SOCKETS or MQGROUP statements as they appear in the control card deck.

User Response: Correct the errors and retry the playback.

TCPPBST-0023E SOCKETS/MQGROUP=n VALIDATED SCRIPT=scrpt VALIDATED. RETURN CODE=rc

Explanation: Playback status information.

When rc=0, the SCRIPT statement was valid. When rc=8, errors were found in the SCRIPT statement.

User Response: Informational message. No user action necessary.

TCPPBST-0047E INVALID TOKEN FOUND: iiiiiiii

Explanation: The token iiiiiiii identified by this message is not valid.

User Response: Correct the invalid token and re-run.

TCPPBST-0058E MAXWAIT MUST BE GREATER THAN 15 SECONDS

User Response: Increase MAXWAIT value to more than 15 seconds.

TCPPBST-0209E object_name IS NOT A VALID OBJECTNAME

User Response: Correct the error in object_name and re-run the playback.

TCPPBST-0251W Server playback only supports DB2C and TCP protocols. PROTOCOL(TCP) will be used instead.

Explanation: The only protocols supported by server playback are DB2C or TCP.

User Response: Specify either DB2C or TCP as the protocol in either the CONTROL or SOCKETS statement.

TCPPBST-0253E SOCKETS statement=<socket-number> SCRIPT statement=<script-number> is invalid.

Explanation: This error and TCPPBST - 0254I which follows immediately after this message indicate that script <script-number> for socket <socket-number> is not valid because server playback supports only one SCRIPT statement per SOCKETS statement.

Code Description

n Hiperstation assigns this number serially, in the order in which the SOCKETS/MQGROUP statements occur.

scrpt The name of the SCRIPT statement.

Page 271: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-23

User Response: Correct the control cards so that each SOCKETS statement has only one SCRIPT statement.

TCPPBST-0254I A SOCKETS statement must only have one SCRIPT statement for a server playback.

Explanation: This error immediately follows TCPPBST - 253E and indicates that server playback supports only one SCRIPT statement per SOCKETS statement.

User Response: Correct the control cards so that each SOCKETS statement has only one SCRIPT statement.

TCPPBST-0256E PLAY(SERVER) is invalid for a Websphere MQ Playback

Explanation: The PLAY(SERVER) parameter is valid only for TCP/IP playback.

User Response: Remove the PLAY(SERVER) parameter from the CONTROL statement.

TCPPBST-0266E <option> is a required option on the <statement-type> statement when doing a <type> playback.

Explanation: <type> can be either client or server. <statement-type> is either CONTROL or SOCKETS. <option> is required for the type of playback being done.

User Response: Either specify the <option> on the statement or change the type of playback being done.

TCPPBUTLTCPPBUTL-0052I CURRENT CONTROL CARD=sssssss

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPPBUTL-0054E STORAGE REQUEST INVALID FOR LEN=xxxxx

Explanation: Playback fails.

User Response: Contact Compuware Customer Support.

TCPPBUTL-0077I FILE ALLOCATION ERROR - DDN: dddddddd, DSN: ssssssss RETURN CODE=rc-ec

Explanation: Hiperstation could not allocate the DSN to the DDN.

User Response: Return code information can be found in the SVC 99 (DYNALLOC) description in the MVS Programming: Authorized Assembler Services Guide, IBM Document Number GC28-1763-07.

TCPPBUTL-0078E FILE OPEN ERROR - DDN: dddddddd

Explanation: Hiperstation could not open DDNAME dddddddd. This message is followed by another message describing the script record in error.

User Response: Informational message. No user action necessary.

TCPPBUTL-0097E COULD NOT IDENTIFY OBJECT TYPE AT: addr-objid.

Explanation: Internal message, possibly due to a storage shortage.

User Response: Be sure that REGION=0M is specified on the EXEC statement.

TCPPBUTL-0116E UNABLE TO SATISFY REQUEST FOR STORAGE. REQUESTED LENGTH: len

Explanation: There is insufficient storage in the playback job to satisfy the storage request.

User Response: Increase the storage available via the REGION parameter and re-run the playback.

Page 272: Hiperstation Messages and Codes

6-24 Hiperstation Messages and Codes

TCPPROTTCPPROT-0183I PPPP xxxxxxx message length(nnnn) differ from protocol length(nnnn) for EVID=nn. where PPPP is one of ECI, CTG, DB2C; xxxxxxx is either Outbound or Expected; nnnn and nn are a numeric value

Explanation: During TCP playback for protocol PPPP, the discrepancy in the message length had been found. EVID=nn is the value in the script where <CLIENT ID=k>nn or <SERVER ID=k>nn. For online playback, protocol length will be replaced with actual message length.

User Response: This is an informational message. If online playback fails, correct script where EVID=nn applies and replay.

TCPPROT-0213W LOAD FOR PROTOCOL:xxxx FAILED

Explanation: A request to a partner application using protocol xxxx was found in the script. To use protocol xxxx the DLL xxxx must be a member in the STEPLIB execution library.

User Response: This is most likely a control card or script specification error. Change the PROTOCOL to HTTP or HTTPS and rerun the job.

TCPRCTCPRC-0000I DATA RECORD ACTIVATED

Explanation: The token iiiiiiii identified by this message is not valid.

TCPRC-0009I TCP/IP RECORDER SHUTDOWN ACKNOWLEDGED

Explanation: The Hiperstation TCP/IP data recorder is terminating.

User Response: Informational message. No user action necessary.

TCPRC-0010I TCP/IP RECORDER SHUTDOWN COMPLETE

Explanation: The Hiperstation TCP/IP data recorder has terminated.

User Response: Informational message. No user action necessary.

TCPRC-0100W ECSA BUFFERS NOT LARGE ENOUGH, XXXXXXXX RECORDS LOST SO FAR

Explanation: There were more TCP or MQ events than the ECSA buffers could handle. XXXXXXXX indicates the number of events lost.

System Action: Hiperstation presents this message when the first event is lost and again after each 100 events are lost. It also presents message TCPRC915I to aid you with troubleshooting.

User Response: If this message occurs only at Global Record startup, and no TCP or MQ Global Recording Requests are active, ignore this message. Otherwise, complete the following steps.

• Ensure the started task dispatch priority is above all TCP/IP generating address spaces. If WLM goal mode is active, dispatch rate is determined by the VELOCITY of the performance group. The IBM default group, SYSSTC, is a good starting point for most systems.

• Access the Statistics panel from the HIPERSTATION Product Menu panel by issuing the primary command STATS and then access the TCP/IP specific panel by issuing the command TCP on the STATS primary command line. Evaluate the ECSA Max Used and the Volume and Count fields and set TCPBUFL and TCPBUFS accordingly. If activity varies throughout the day, turn on statistics by issuing the MVS MODIFY command “STATSON” for the Global Record address space. Monitor the ECSA and Volume and Count fields for during the increased activity periods and increase TCPBUFS and TCPBUFL to create additional ECSA buffers to handle the activity spikes. Refer to the Hiperstation Installation and Configuration Guide for more information.

Page 273: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-25

TCPRC-0101E nnnnnnnn RECORDS TOO LONG. INCREASE TCPBUFS*TCPBUFL VALUE

Explanation: Hiperstation has rejected nnnnnnnn records because they exceeded the size specified in the TCPRECLM SYSIN parameter or TCPBUFS*TCPBUFL if TCPRECLM is not specified. TCPBUFS is the number of ECSA buffers to allocate for TCPIP and MQ, and TCPBUFL is each ECSA buffer size in kilobytes.

User Response: If you need to capture larger records specify a larger value in TCPRECLM (refer to the Hiperstation Installation and Configuration Guide). Otherwise, this message is informational and can be ignored. If TCPRECLM is specified, it should be less than TCPBUFS*TCPBUFL.

TCPRC-0200W RECORDING TERMINATED DUE TO FULL REPOSITORY

Explanation: A recording request has been terminated because the specified repository has been filled. A message will also be issued to the TSO user ID that started the request.

User Response: Use a larger repository if needed.

TCPRC-0201E RECORDING TERMINATED DUE TO REPOSITORY I/O ERROR

Explanation: A recording request has been terminated because the specified repository has received an I/O error. A message will also be issued to the TSO user ID that started the request.

User Response: Check the system log for more messages that may indicate the specific I/O error.

TCPRC-0900E TCP/IP RECORDER ESTAE ENTERED

Explanation: The Hiperstation TCP/IP data recorder has abended. Hiperstation will terminate.

User Response: Collect all messages in the system log, save the dump and contact Compuware Customer Support.

TCPRC-0901E NO RETRY, WILL NEED RESTART

Explanation: The Hiperstation TCP/IP data recorder has abended. Hiperstation will terminate.

User Response: Collect all messages in the system log, save the dump and contact Compuware Customer Support.

TCPRC-0904E BUFFER OVERRUN. PLEASE CALL HIPERSTATION SUPPORT

Explanation: An internal buffer error has occurred.

User Response: Collect all messages in the system log, save the dump and contact Compuware Customer Support.

TCPRC-0905E NOT ENOUGH MEMORY FOR BUFFERS

Explanation: Hiperstation was unable to initialize the TCP/IP data recorder because there was not enough memory. Hiperstation will terminate.

TCPRC-0910I MORE TADRS NEEDED

Explanation: The TADR data structure is used internally by Hiperstation to keep track of active TCP connections in the MVS system. The initial number of QADRs obtained is controlled by the CONNCNT parameter in the Global Recording startup parameters. This message appears if Hiperstation has to keep track of more TCP connections than are specified on the CONNCNT parameter.

System Action: Hiperstation tries to obtain additional QADRs.

User Response: Eliminate this message by setting a CONNCNT value larger than the maximum number of simultaneous TCP connections on your system. For each occurrence of this message, increase the existing CONNCNT value by minimally 25%. For example, if the existing CONNCNT is 1000 and you receive three of these messages, increase the CONNCNT to 1750. Setting an appropriate CONNCNT value improves performance.

TCPRC-0912I MORE QARDS NEEDED

Explanation: The QADR data structure is used internally by Hiperstation to keep track of active MQ sessions in the MVS system. The initial number of QADRs obtained is controlled by

Page 274: Hiperstation Messages and Codes

6-26 Hiperstation Messages and Codes

the MQSESCNT parameter in the Global Recording startup parameters. This message appears if Hiperstation has to keep track of more MQ sessions than are specified on the MQSESCNT parameter.

System Action: Hiperstation tries to obtain additional QADRs.

User Response: Eliminate this message by setting an MQSESCNT value larger than the maximum number of simultaneous MQ sessions on your system. For each occurrence of this message, increase the existing MQSESCNT value by minimally 25%. For example, if the existing MQSESCNT is 100 and you receive three of these messages, increase the MQSESCNT to 175. Setting an appropriate MQSESCNT value improves performance.

TCPRC-0915I B=AAAAAAAA/BBBBBBBBBB R=CCCCCCCCCC/DDDDDDDDDD C=EE%

Explanation: This message accompanies message TCPRC100W. It provides statistics to help you troubleshoot the warning. AAAAAAAA = Bytes processed on current pass. BBBBBBBBBB = Bytes processed since Global Record startup CCCCCCCCCC = Bytes per CPU second on current pass DDDDDDDDDD = Bytes per CPU second send Global Record startup EE = Percentage of CPU used in last pass.

User Response: If EE seems high, review the CONNCNT (TCP) or MQSESCNT (MQ) values to ensure they are set appropriately. If AAAAAAAA is much larger than the TCP buffer length (TCPBUFL), Hiperstation may be falling behind. Either increase the value of TCPBUFL or the dispatch priority of the started task. Note: If WLM goal mode is active, dispatch rate is determined by the VELOCITY of the performance group. The IBM default group, SYSSTC, is a good starting point for most systems.If this message occurs only during times of peak TCP/IP and MQ activity, increase the value of TCPBUFS. Note: CONNECT, MQSESCNT, TCPBUFL, and TCPBUFS reside in SQQFSAMP member GRPARMS.

TCPREVNTTCPREVNT-0001W REPLAY=r REQUEST_TYPE REQUEST: STORAGE_ADDR STILL ACTIVE TERMINATION REQUEST DELAYED

Explanation: A request to free storage at storage_addr has been delayed. The storage is still in use.

User Response: Informational message. No user action necessary.

TCPREVNT-0015W REPLAY=r CONNECTION=y CONNECTION WITH PARTNER WAS UNEXPECTEDLY LOST

Explanation: The partner disconnected the connection for the replay. This may or may not be normal.

User Response: Review the script actions for connection y for CLIENT-SERVER tag pairs to ensure that a response was expected from the partner.

Code Description

x The number associated with the replay of the script. It is assigned by Hiperstation for Mainframe Servers serially in the order in which the script replay starts.

y The connection ID or number found on the ID= parameter of the <CONNECT> statement on the script.

Page 275: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-27

TCPREVNT-0072W REPLAY=r INVALID CONNECTION STATUS FOR CONNECT/MQOPEN REQUEST ON CONNECTION/OBJECT=y STATUS=st

Explanation: The CONNECT/MQOPEN request could not be processed. The connection/queue must be IDLE, CONNECTING, or DISCONNECTED. Valid connection states are:

User Response: Correct the connection status and re-run.

TCPREVNT-0080E REPLAY=r SERVER_PORT NUMBER WAS INVALID

Explanation: SERVER_PORT must be numeric.

User Response: Ensure that the value for SERVER_PORT is numeric.

TCPREVNT-0081E REPLAY=r CONNECTION/OBJECT=y IO ERROR PLAYING SCRIPT RECORD=rid TYPE=type RV=rv RC=rc RSN=reason

Explanation: An input/output operation was requested but did not complete successfully.

System Action: The connection was refused by the server.

User Response: The connection was refused due to your system security package. Probably, the Jobname did not have authority to make the TCP/IP connection. Notify your MVS system administrator.

TCPREVNT-0086W REPLAY=r statement_type: statement_nbr - UNKNOWN EVENT TYPE=type

Explanation: An invalid script record was found and ignored.

User Response: Informational message. No user action necessary.

TCPREVNT-0088E REPLAY=r CONNECTION/OBJECT=y UNKNOWN I-0 REQUEST TYPE = z

Explanation: Internal processing error.

User Response: Contact Compuware Customer Support.

Connection State Code

CONNECTION_IDLE 1

CONNECTION_AVAILABLE 2

CONNECTION_BUSY 3

CONNECTION_CONNECTING 4

CONNECTION_READING 5

CONNECTION_WRITING 6

CONNECTION_DISCONN 7

CONNECTION_PLAY_SYNC 8

CONNECTION_CONN_RETRY 9

Code Description

rid The script record of the request.

TYPE The operation requested (e.g. MQ_PUT_CONTENT).

RV The return value from the request. Often this will be a -1 for unsuccessful I-O requests.

RC The return code of the request.

RSN The reason code for the failure. This normally is the Reason returned by either the sockets interface or MQ.

Page 276: Hiperstation Messages and Codes

6-28 Hiperstation Messages and Codes

TCPREVNT-0090W REPLAY=r CONNECTION: id PARTNER DID NOT RESPOND TO CLIENT REQUEST. SCRIPT RECORD=rid

User Response: Informational message. No user action necessary.

TCPREVNT-0091W REPLAY=r CONNECTION REQUEST FAILED FOR CONNECTION=y RETURN CODE=rc

Explanation: The connection request failed. Warning message.

User Response: Informational message. No user action necessary.

TCPREVNT-0099W REPLAY=r ATTEMPTING ZERO LENGTH WRITE CONNECTION=y - SCRIPT RECORD=rid

Explanation: The script record (rid) had no associated data.

User Response: Informational message. No user action necessary.

TCPREVNT-0107E REPLAY=r CONNECTION=cn LAST SCRIPT RECORD=rid UNEXPECTED RESPONSE FROM THE SERVER: ssssss

Explanation: In response to the last send, Hiperstation for Mainframe Servers received a data stream not supported by the message type (HTTP). For HTTP connections this may result in a connection termination.

User Response: Informational message. No user action necessary.

TCPREVNT-0108W REPLAY=r CONNECTION=cn CONNECTION WITH PARTERNER WAS LOST. RETURN CODE=rc

Explanation: An I-O request was rejected by TCP. This is normally due to an unexpected termination of the connection by the partner.

User Response: Informational message. No user action necessary.

TCPREVNT-0116E UNABLE TO SATISFY REQUEST FOR STORAGE. REQUESTED LENGTH=I

Explanation: Hiperstation could not allocate storage during run time.

User Response: Contact Compuware Customer Support.

TCPREVNT-0117W REPLAY=1 CONNECTION=1 - NO DATA AVAILABLE FROM PARTNER FOR EVID=nnn. SETTING RC=4.

Explanation: There is insufficient data on the queue or TCP/IP connection to satisfy a read request. This may or may not be an error. When EVID=0 for TCPREVNT-0117W, refer to TCPASYNC-0184I for correct EVID.

User Response: You may wish to review the actual and expected message data to determine the reason for different message data during the replay. Ensure you collect message table information including fields ResponseBody(RSBD) and ExpectedResponseBody(EXBD) during the replay. Produce a report displaying these fields (see Hiperstation for Mainframe Servers User Guide TCP/IP Reporting Chapter for information on reporting) and review the message contents to determine the reason for different message data during the replay.

TCPREVNT-0217E REPLAY=(N) CONNECTION=(N) (HTTP/1.1) (CLIENT/SERVER) ERROR RC=(NNN) REASON: (HTTP TEXT)

Explanation: An HTTP response was received containing either a 4xx client or a 5xx server error.

User Response: For information on these errors, refer to the W3 Consortium Web site: http://www.w3.org/Protocols/rfc2616/rfc2616-sec10.html.

TCPREVNT-0264W Replay=<replay-number> %s=%i - Read timeout on server playback

Explanation: The STDWAIT value specified either the SOCKETS statement or the CONTROL statement has been exceeded. The playback of the socket is terminated.

System Action: None.

User Response: Specify a larger value for the STDWAIT parameter or ensure that client applications reply within the specified STDWAIT period specified.

Page 277: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-29

TCPRPLWKTCPRPLWK-0112E REPLAY=r REPLACE: rpl IN SCRIPT:sssss NOT EXECUTED REASON: rsn - LAST SCRIPT RECORD=rid

Explanation: rid is the last script record read.

User Response: Correct the error on the REPLACE tag.

TCPRPTCTCPRPTC-1125E REPORT FILE OPEN FAILED

User Response: Add or correct DDName specified in the JCL which are used in the DATABASE(ddname) of the playback control card.

TCPRPTC-1126E REPORT FILE NOT VARIABLE LENGTH

User Response: Ensure that the report file is of variable length and retry.

TCPRPTC-1127E INVALID CONTROL STATEMENT

User Response: Correct the invalid control statement and retry.

TCPRPTC-1128E INVALID SYNTAX - MISSING FROM (

User Response: Correct the invalid syntax and retry.

TCPRPTC-1129E PREMATURE END OF STATEMENT

User Response: The COLLECTION control card is not complete. Correct and retry.

TCPRPTC-1130E INVALID TABLE NAME

User Response: Correct the invalid table name and retry.

TCPRPTC-1131E DUPLICATE TABLE NAME

User Response: Eliminate or change the duplicate table name and retry.

TCPRPTC-1132E FIELDNAME INVALID FOR THE SPECIFIED TABLE.

User Response: Correct the invalid field name and retry.

TCPRPTC-1133E UNBALANCED OPEN_PAREN - FIELDS (.(.).)

User Response: Correct the unbalance and retry.

TCPRPTC-1134E INVALID SYNTAX - MISSING WHERE (

User Response: Add WHERE and retry.

TCPRPTC-1135E INVALID SYNTAX - MISSING FIELDS (

User Response: Add the missing fields and retry.

TCPRPTC-1136E INVALID TOKEN/SYNTAX WITHIN - FIELDS (.(.).)

User Response: Correct the invalid token or syntax and retry.

TCPRPTC-1137E INVALID SYNTAX FOUND WITHIN TOKEN ROUTINE

User Response: Correct the invalid syntax and retry.

TCPRPTC-1138E SUBSTR START VALUE MUST BE NUMERIC > 0

User Response: Ensure that the start value is numeric and greater than zero and retry.

TCPRPTC-1139E SUBSTR LENGTH VALUE MUST BE NUMERIC > 0

User Response: Ensure that the length value is numeric and greater than zero and retry.

Page 278: Hiperstation Messages and Codes

6-30 Hiperstation Messages and Codes

TCPRPTC-1140E VALID FIELDNAME BUT FROM INCORRECT TABLE

User Response: Correct table and retry.

TCPRPTC-1141E LITERAL IN QUOTES NOT CHAR, HEX

User Response: Ensure that the literal is either in char or hex form and retry.

TCPRPTC-1142E LITERAL IN QUOTES NO ENDING QUOTE

User Response: Add ending quote and retry.

TCPRPTC-1143E CHARACTER LITERAL OF ZERO LENGTH IS INVALID

User Response: Add a non-zero length character literal and retry.

TCPRPTC-1144E LITERAL NOT NUMERIC, HEX, OR IN QUOTES

User Response: Correct the literal to a numeric or hex value, or add quotes and retry.

TCPRPTC-1145E HEX LITERAL NOT AN EVEN NUMBER OF POSNS

User Response: Correct to an even number of positions and retry.

TCPRPTC-1146E HEX LITERAL CONTAINS DATA NOT 0-9, A-F

User Response: Correct the data and retry.

TCPRPTC-1147E NUMERIC LITERAL GREATER THAN MAXIMUM

Explanation: The number you specified on the COLLECT statement is too large for Hiperstation to parse.

User Response: Change the number to a lower value. The maximum value allowed is approximately 1038.

TCPRPTC-1148E INVALID COMPARE OPERATOR IN WHERE CLAUSE

User Response: Correct the invalid compare operator and retry.

TCPRPTC-1149E NUMERIC LITERAL CONTAINS NON-NUMERICS

User Response: Correct the non-numerics and retry.

TCPRPTC-1150E MULTIPLE DECIMAL POINTS IN FLOATING POINT LITERAL

User Response: Eliminate multiple decimal points in the floating point literal and retry.

TCPRPTC-1151E SUBSTR INVALID WITH NON-CHARACTER DATA

User Response: Correct invalid SUBSTR and retry.

TCPRPTC-1152E MONTH GREATER THAN 12

User Response: Correct the error in the MONTH field and retry.

TCPRPTC-1153E DAY GREATER THAN 31

User Response: Correct the error in the DAY field and retry.

TCPRPTC-1154E HOUR GREATER THAN 24

User Response: Correct the error in the HOUR field and retry.

TCPRPTC-1155E MINUTE GREATER THAN 59

User Response: Correct the error in the MINUTE field and retry.

TCPRPTC-1156E SECOND GREATER THAN 59

User Response: Correct the error in the SECOND field and retry.

TCPRPTC-1157E YEAR NOT NUMERIC

User Response: Correct the error in the YEAR field and retry.

Page 279: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-31

TCPRPTC-1158E MONTH NOT NUMERIC

User Response: Correct the error in the MONTH field and retry.

TCPRPTC-1159E DAY NOT NUMERIC

User Response: Correct the error in the DAY field and retry.

TCPRPTC-1160E HOUR NOT NUMERIC

User Response: Correct the error in the HOUR field and retry.

TCPRPTC-1161E MIN NOT NUMERIC

User Response: Correct the error in the MINUTE field and retry.

TCPRPTC-1162E SEC NOT NUMERIC

User Response: Correct the error in the SECONDS field and retry.

TCPRPTC-1163E FRACTION NOT NUMERIC

User Response: Correct the error in the FRACTION field and retry.

TCPRPTC-1174 HOUR=24 NO MINUTE, SECOND, FRACTION ALLOWED.

Explanation: When a timestamp is referenced within a WHERE clause and the compare-to value specifies an hour of 24, then no minutes, seconds, or fractions of seconds is valid.

User Response: To reference a time past midnight, change the compare-to value hour to 00.

TCPRPTC-2122E REPORTING DATABASE FULL. TERMINATING PLAYBACK.

Explanation: The reporting database is full.

User Response: Increase the size of the reporting database.

TCPSCRSTCPSCRS-0035E SCRIPT NOT FOUND=ssssssss

Explanation: This error is most likely due to an invalid script name, or the script is not a member of the dataset associated with the SYSLIB DD.

User Response: Ensure that the SYSLIB DD points to the correct script dataset, or correct your SCRIPT statement.

TCPSCRS-0036E OPEN FAILED FOR SCRIPT=xxxxxxxx

Explanation: This error is most likely due to an invalid script name, or the script is not in the dataset associated with the SYSLIB DD.

User Response: Ensure that the SYSLIB DD points to the correct script dataset, or correct your SCRIPT statement.

TCPSCRS-0037E SCRIPT ALLOCATION FAILURE SCRIPT name=xxxxxx - ERROR CODE=ec - INFO CODE=ic

Explanation: While attempting to load script xxxxxx into cache, Hiperstation could not allocate the temporary DDNAME TCPSCRS.

User Response: Ensure that no TCPSCRS DD statement is in your batch JCL. Also ensure that the script xxxxxx is a member of the dataset associated with your SYSLIB DD. For more information on the error code and information code, see MVS Programming: Authorized Assembler Services Guide, IBM document number GC28-1763-07.

TCPSCRS-0038E READ FAILED FOR SCRIPT=xxxxxxx

Explanation: An error occurred loading script xxxxxxx into cache.

User Response: Remove the CACHE parameter from the CONTROL statement and re-run.

Page 280: Hiperstation Messages and Codes

6-32 Hiperstation Messages and Codes

TCPSCRS-0039E UNABLE TO OPEN CACHE FOR SCRIPT=xxxxxxx

Explanation: An error occurred opening the memory cache for script xxxxxxx.

User Response: Remove the CACHE parameter from the CONTROL statement and re-run.

TCPSCRS-0040E UNABLE TO CACHE SCRIPT=xxxxxxx

Explanation: An error occurred putting a script record from script xxxxxxx into cache.

User Response: Remove the CACHE parameter from the CONTROL statement and re-run.

TCPSCRS-0041E INVALID SCRIPT STATEMENT SOCKETS STATEMENT=n SCRIPT=y

System Action:

User Response: Correct associated errors and re-run.

TCPSCRS-0042E NO SCRIPT NAME FOUND FOR SOCKETS/MQGROUP STATEMENT=group_id SCRIPT=script_id

Explanation:

User Response: Include a script name on the SCRIPT statement.

TCPSCRS-0043E SCRIPT NAME TOO LONG FOR SOCKETS/MQGROUP=n SCRIPT=y

Explanation:

User Response: Correct associated errors and re-run.

TCPSCRS-0044E REPEAT PARAMETER ERROR FOR SOCKETS/MQGROUP=n SCRIPT=y

Explanation:

User Response: Correct associated errors and re-run.

Code Description

x Assigned by Hiperstation serially, in the order in which the SOCKETS or MQGroup statements occur.

y Assigned by Hiperstation serially, in the order in which the SCRIPT statement occurs under the SOCKETS statement.

Code Description

group_id The sequential number of the SOCKETS/MQGROPU statement in the control card deck.

script_id The script statement number underneath the SOCKETS/MQGROUP statement.

Code Description

n Assigned by Hiperstation serially, in the order in which the SOCKETS/MQGROUP statements occur.

y Assigned by Hiperstation serially, in the order in which the SCRIPT statement occurs under the SOCKETS/MQGROUP statement.

Code Description

n Assigned by Hiperstation serially, in the order in which the SOCKETS/MQGROUP statements occur.

y Assigned by Hiperstation serially, in the order in which the SCRIPT statement occurs under the SOCKETS/MQGROUP statement.

Page 281: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-33

TCPSCRS-0045E REPEAT PARAMETER ERROR FOR SOCKETS/MQGROUP=n SCRIPT=y

Explanation:

User Response: Correct associated errors and re-run.

TCPSCRS-0046E iiiiiiii FIELD MUST BE NUMERIC

Explanation: The parameter iiiiiiii identified by this message must be numeric.

User Response: Correct associated errors and re-run.

TCPSCRS-0048E iiiiiiii FIELD IS INVALID IN SOCKETS/MQGROUP=n SCRIPT=scrpt

Explanation: The parameter iiiiiiii identified by this message must be numeric.

User Response: Correct associated errors and re-run.

TCPSCRS-0049E UNBALANCED PARENTHESIS AT pppppppp IN SCRIPT=ssssssss -- SOCKETS/MQGROUP=n SCRIPT=y

Explanation:

User Response: Correct associated errors and re-run.

TCPSCRS-0062W REPLAY=r INVALID SCRIPT RECORD FOUND DATA=xxxxxxxxxx

Explanation: Warning message.

User Response: Informational message. No user action necessary.

TCPSCRS-0180I SQL record value has invalid REXX string format

Explanation: The SQL value you supplied does not meet the syntax requirements for REXX strings.

User Response: Refer to playback user guide for correct syntax.

Code Description

n Assigned by Hiperstation serially, in the order in which the SOCKETS/MQGROUP statements occur.

y Assigned by Hiperstation serially, in the order in which the SCRIPT statement occurs under the SOCKETS/MQGROUP statement.

Code Description

iiiiiiii Name of the invalid field

n Assigned by Hiperstation serially, in the order in which the SOCKETS/MQGROUP statements occur.

scrpt Name of the script.

Code Description

pppppppp The parameter in error.

ssssssss Name of the script identified by SCRIPT(ssssssss).

n Assigned by Hiperstation serially, in the order in which the SOCKETS statements occur.

y Assigned by Hiperstation serially, in the order in which the SCRIPT statement occurs under the SOCKETS statement.

Page 282: Hiperstation Messages and Codes

6-34 Hiperstation Messages and Codes

TCPSCSETTCPSCSET-0026E SOCKETS/MQGROUP=n UNABLE TO SET UP INTRA-TASK MESSAGING

User Response: Ensure that the playback job is run with POSIX(ON) and REGION=0M.

TCPSCSET-0027E SOCKETS/MQGROUP=n UNABLE TO SET UP RESOURCE LOCKING

User Response: Ensure that the playback job is run with POSIX(ON) and REGION=0M.

TCPSCSET-0028I SOCKETS/MQGROUP=n BEGINNING REPLAY

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSCSET-0030I BYPASSING PROCESSING FOR SCRIPT=scrpt SOCKETS/MQGROUP=n, DUE TO PRIOR ERRORS

User Response: Correct the errors and rerun the playback.

TCPSCSET-0031I PLAY COMPLETE FOR SOCKETS/MQGROUP=n - RETURN CODE=rc

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSCSET-0032I SOCKETS/MQGROUP=n PUTTING SCRIPTS INTO CACHE

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSCSET-0033E REPLAY INITIALIZATION FAILED FOR SOCKETS/MQGROUP=n

User Response: Ensure that the playback job is run with POSIX(ON) and REGION=0M.

TCPSCSET-0034I SOCKETS/MQGROUP=n TERMINATING REPLAY=r

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSCSET-0085I SOCKETS/MQGROUP=n - x OUT OF y REPLAYS COMPLETE

Explanation: When the COUNT parameter is included on the SOCKETS/MQGROUP statement, this status information appears, showing how many (x) out of the COUNT (y) have completed.

TCPSCSET-0092E SOCKETS/MQGROUP STATEMENT=statement_nbr REPLAY=r CANCELLED DUE TO INACTIVITY. NO I-0 FOR max_wait SECONDS.

Explanation: A COUNT parameter was included on a SOCKETS/MQGROUP statement but Hiperstation could not start one of the requested COUNT parameters.

TCPSCSET-0095E UNABLE TO START REPLAY FOR SOCKETS/MQGROUP=n REASON: sssss

Explanation: A COUNT parameter was included on a SOCKETS/MQGROUP statement but Hiperstation could not start on n of the requested COUNT.

User Response: Ensure that REGION=0M. If it is, then the requested playback is too large for your system. Decrease the number of simultaneous users requested.

TCPSEVNTTCPSEVNT-0063W REPLAY=r UNABLE TO DETERMINE RECORD TYPE. SCRIPT RECORD=rid

Explanation: Warning message.

User Response: Informational message. No user action necessary.

Page 283: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-35

TCPSEVNT-0066E REPLAY=r UNABLE TO DETERMINE TYPE FOR SCRIPT RECORD: xxxxxx

Explanation: The script record found could not be played.

User Response: Remove or correct the script record.

TCPSEVNT-0067E REPLAY=r Object=y QUEUE IS NOT AVAILABLE

Explanation: TCP/IP - A duplicate CONNECT statement exists for connection y. MQSeries - a duplicate OBJECT exists, therefore the queue is not available.

User Response: Correct the duplicate statement and re-run.

TCPSEVNT-0068E REPLAY=r CONNECTION=y HAS NOT BEEN ESTABLISHED. SCRIPT RECORD=rid

Explanation: A CLIENT or SERVER tag has been found for an ID=y, but there was no prior CONNECT ID=y statement or the CONNECT statement for ID=y was invalid.

User Response: Correct the CONNECT statement and re-run.

TCPSEVNT-0073W REPLAY=r UNABLE TO PLAY - TYPE=type SCRIPT RECORD=rid - RETURN CODE=rc

Explanation: The script record could not be played due to prior errors. Script record types are

User Response: Review prior messages for errors.

TCPSEVNT-0074E REPLAY=r INVALID SCRIPT RECORD FOUND DATA=xxxxxxxxxxxxxxxxx

Explanation: Script record parameter error found in the data xxxxxxxxxxxxxxxxx.

TCPSEVNT-0076I REPLAY=r PLAY COMPLETE FOR SCRIPT=ssssssss.

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSEVNT-0084W REPLAY=r IO FAILURE FOR CONNECTION=y AFTER n RETRIES

Explanation: The TCP request was attempted n times.

User Response: Informational message. No user action necessary.

Code Description

1 NON_IO

2 CONNECT

3 CLIENT

4 SERVER

5 CLIENT_CONTENT

6 SERVER_CONTENT

7 DISCONNECT

8 SSLCLIENT

9 SSLSERVER

10 LISTEN

11 COMMENT

12 CONTENT

13 TIME_CARD

14 EndOFFile (internal)

15 DETAIL

16 REPLACE

Page 284: Hiperstation Messages and Codes

6-36 Hiperstation Messages and Codes

TCPSEVNT-0098E REPLAY=r - ERROR ACCESSING SCRIPT:ssssss FROM RECORD: frm TO RECORD: torec - REASON=rsn

Explanation: The CONTENT data could not be retrieved from an external file. The script and the script content data are in separate datasets. This error occurs when the script points to content records that are not in the content dataset.

User Response: Ensure that the script matches the content data.

TCPSEVNT-0105E ERRORS FOUND IN SCRIPT RECORD=rid RECORD: dddddddddd.

Explanation: This message is often associated with other messages detailing the type of error or the parameter in error.

User Response: Locate the script record and correct the errors.

TCPSEVNT-0106E REPLAY=r INCOMPLETE CLIENT MESSAGE=y ON CONNECTION=cn

Explanation: A SERVER record was found before Hiperstation for Mainframe Servers had built a complete CLIENT message. For HTTP connections, this will likely result in connection termination.

TCPSEVNT-0109E REPLAY=r INVALID PROTOCOL FOUND: xxx

User Response: Correct the PROTOCOL statement or remove the invalid CONNECT statement.

TCPSEVNT-0110E REPLAY=r REPLACE FIELD: fld IN SCRIPT: sssss IS INVALID. LAST SCRIPT RECORD=rid

Explanation: The REPLACE field is invalid.

User Response: Correct the REPLACE field.

TCPSEVNT-0111E REPLACE FIELD: rpl IN SCRIPT: sssss NOT EXECUTED. REASON: rsn LAST SCRIPT RECORD:rid

Explanation: rid is the last script record read.

User Response: Correct the error on the REPLACE tag.

TCPSEVNT-0121W REPLAY=r CONNECTION=cid RECORD=rid CONSECUTIVE SERVER TAGS WITHOUT INTERVENING CLIENT.

Explanation: A script sequencing problem was found. A <CLIENT..> tag was expected but a <SERVER..> tag was found. The <SERVER..> tag is skipped.

User Response: Informational message. No user action necessary.

TCPSEVNT-0181I Data value missing hex indicator

Explanation: The keyword specified is expecting its data in hexadecimal format.

User Response: Place an “X” after the data. Example: DB2_NPASS = '40C1417853453798'X.

TCPSEVNT-0182I Data value should be enclosed in single quotes

Explanation: The keyword specified required data to be enclosed in single quotes.

User Response: Ensure data is preceded and followed by a single quote.

TCPSEVNT-0270I Replay=1 Conn=1 CTG Ping_Pong skipped SCRIPT=SCTGAS00 EVID=9 <SERVER>Replay=1 Conn=1 CTG Ping_Pong skipped SCRIPT=SCTGAS00 EVID=10 <CLIENT>

Explanation: Ping-pong entries exist in the script and are being skipped.

TCPSEVNT-0271I Replay=1 Conn=1 TCPPB handled CTG Ping SCRIPT=SCTGAS00 for EVID=11

Explanation: Later in the playback, we received a ping from the server and replied with pong.

Page 285: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-37

TCPSEVNT-0272I Replay=1 Conn=2 CTG Async msg skipped SCRIPT=SCTGAS00 EVID=26 <SERVER>

Explanation: We found an async confirm message (ECI type) and ignored this server message.

TCPSEVNT-0273I Replay=1 Conn=2 TCPPB handled CTG Async msg SCRIPT=SCTGAS00 for EVID=27

Explanation: Later in the playback, we received an async confirm message from the server and ignored it.

TCPSOCKTTCPSOCKT-0017E REPLAY=R CONNECTION=ID UNABLE TO OBTAIN TCP SOCKET. REASON: rc

Explanation: An attempt was made to open a TCP/IP socket to implement the connection ID in the script. The sockets call failed with reason code rc. Most likely the maximum number of open sockets defined by OMVS was reached.

User Response: Increase the maximum number of open sockets allowed by OMVS or decrease the size of the playback.

TCPSOCK-0265I Server playback stopped listening on port <port-number>

Explanation: All SOCKETS statements have been connected to on the specified port and the playback listener has been terminated.

System Action: None.

User Response: None.

TCPSRPLTCPSRPL-0012E FOUND COMPLETED I-0 ON INCOMPLETE QUEUE - WAITING FOR COMPLETION PROCESS

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSRPL-0050I SOCKETS/MQGROUP=n STARTING REPLAY=r

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSRPL-0051I PLAY COMPLETE FOR REPLAY=r RETURN CODE=rc

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

Code Description

n Assigned by Hiperstation serially, in the order in which the SOCKETS statements occur.

r The number associated with the replay of the script. It is assigned serially in the order in which the script replay is started.

Code Description

r The number associated with the replay of the script. It is assigned serially in the order in which the script replay is started.

rc The highest return code associated with that replay.

Page 286: Hiperstation Messages and Codes

6-38 Hiperstation Messages and Codes

TCPSRPL-0059W DISPATCH FAILURE REPLAY=r RETURN CODE=rc

Explanation: The dispatching task could not start processing for replay number r. The task will try dispatching this task later.

User Response: Informational message. No user action necessary.

TCPSRPL-0060E REPLAY=r ERROR OPENING SCRIPT=ssssssss

Explanation: Hiperstation could not access the script in CACHE.

User Response: Remove the CACHE parameter on the CONTROL statement and retry.

TCPSRPL-0069W REPLAY=r REXX FAILED TO INITIALIZE RETURN CODE=x

Explanation: An invalid response was received from the REXX initialization.

User Response: Ensure that you are running with REGION=0M.

TCPSRPL-0070I REPLAY=r TERMINATING DUE TO ERROR ON THIS SCRIPT/SOCKET

Explanation: The ERROR_ACTION control card requested that the script replay be stopped when an error occurred.

User Response: Informational message. No user action necessary.

TCPSRPL-0071I REPLAY=r TERMINATING DUE TO ERROR ON A SEPARATE SCRIPT/SOCKET/MQGROUP

Explanation: An error occurred playing back one of the scripts. The ERROR_ACTION control card requested that due to the error, termination be propagated over all scripts played under each of the SOCKETS/MQGROUPs.

User Response: Informational message. No user action necessary.

TCPSRPL-0075I REPLAY=r PLAYING SCRIPT=ssssssss

Explanation: Playback status information.

User Response: Informational message. No user action necessary.

TCPSRPL-0079E REPLAY=r INVALID STATUS - TERMINATING

Explanation: An internal processing error occurred.

User Response: Contact Compuware Customer Support.

TCPSRPL-0093W REPLAY=r NO I-O ACTIVITY IN (stdwait) SECONDS.

Explanation: This message is usually due to a non-responsive partner. Hiperstation will normally retry the request 3 times. STDWAIT defaults to 15 and can be specified using the STDWAIT on the CONTROL statement.

User Response: Informational message. No user action necessary.

TCPSRPL-0100W REPLAY=r RETRYING ATTACH - REASON=rsn.

Explanation: Hiperstation will retry starting replay(r) multiple times.

User Response: Informational message. No user action necessary.

TCPSRPL-0101E REPLAY=r INVALID PTR FOUND IN COMPLETED I-O QUEUE AT: ADR

Explanation: Severe error.

User Response: Contact Compuware Customer Support.

Code Description

rc112Resource shortage. Hiperstation will wait 90 seconds and retry. This condition is due to a shortage of available threads. The number of threads can be increased by increasing the value on the USS parameter MAXTHREADTASKS.

rc132 Storage shortage. Hiperstation will wait 180 seconds and retry. After three attempts, Hiperstation will skip the replay.

Page 287: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-39

TCPSRPL-0102E REPLAY=r ERROR OCCURRED MERGING SCRIPT MESSAGES. SCRIPT RECORD=rid - REASON=sss

Explanation: The expected data buffer could not be built. Hiperstation will continue processing but the reporting information may be incomplete.

User Response: Informational message. No user action necessary.

TCPSRPL-0103W REPLAY=r CONNECTION=y SCRIPT RECORD=rid SKIPPED REASON: rsn

Explanation: Processing of script record (rid) was bypassed for reason rsn.

User Response: Informational message. No user action necessary.

TCPSRPL-0113W REPLAY=r CONNECTION/OBJECT=i TIMEOUT OCCURRED

Explanation: An input operation was requested on connection or object i. The standard wait period elapsed before the data on the connection or queue was available.

TCPSRPL-0115E REPLAY=r CONNECTION=i NON ZERO SRB STATUS=st FOUND IN THE COMPLETED I-O QUEUE

Explanation: An asynchronous I-O failed with an internal return code of st. The playback is terminated. This is most likely due to a storage shortage.

User Response: Increase the storage available via the REGION parameter and re-run the playback.

TCPSRPL-0115W REPLAY=r CONNECTION=cid NON ZERO SRB STATUS FOUND IN THE COMPLETED I-O QUEUE.

Explanation: Indicates that at least one I-O was not successfully processed by Unix System Services.

TCPSRPL-00263I Ignoring Connection=<connection-number> for Replay=<replay-number> for server playback

Explanation: The script being played back and contains multiple connections. Either the first script is being played back or the connection specified by the ID parameter of the SOCKETS statement.

System Action: None.

TCPSRVRTCPSRVR -0257E Playback server initialization failed: <reason>.

Explanation: An internal playback server occurred. The playback server failed to initiated for the specified reason.

User Response: Contact Hiperstation for Mainframe Servers Customer Support.

TCPSRVR -0258E Server playback unable to connect: <reason>.

Explanation: An internal playback server occurred. The playback server failed to connect or disconnect for the specified reason.

User Response: Contact Hiperstation for Mainframe Servers Customer Support.

TCPSRVR -0259W Client (<ip-address>) attempted to connect to the server, but no matching entries were found

Explanation: The playback server listener is still active and is expecting connections only from specific client addresses. The <ip-address> indicates which client tried to connect to the server.

User Response: There may be a need to determine who is trying to connect to the playback server.

TCPSRVR -0260I Playback server initializing for port <port-number>

Explanation: Indicates that the playback server is attempting to bring up the playback server listener on port <port-number>.

Page 288: Hiperstation Messages and Codes

6-40 Hiperstation Messages and Codes

User Response: None.

TCPSRVR -0261I Playback server successfully initialized on port <port-number>

Explanation: Indicates that the playback server listener has been successfully started.

User Response: Client applications that the playback server will serve can now be safely started.

TCPSRVR -0262E Playback server connection timed out

Explanation: The LISTENWAIT value specified on the CONTROL statement has been exceeded. The playback job is terminated.

User Response: Specify a larger value for the LISTENWAIT parameter of the CONTROL statement or initiate client applications connections within the LISTENWAIT period specified.

TCPSRVR -0267E Playback server is unable to establish a listener on port <port-number>

Explanation: The playback server was unable to do a listen on the port specified on SERVER_PORT option of the CONTROL statement. The port is probably already in use.

User Response: Either try again later when the specified port becomes available or specify a different port.

TCPSRVR -0268E Playback server is unable to allocate the listening socket on port <port-number> (<socket-descriptor>)

Explanation: Creation of the listening socket for the server playback failed.

User Response: Ensure that the userid submitting the job has adequate permission to create AF_INET sockets, that resources are available, or that the network is functioning properly.

TCPSRVR -0269E Playback server failed to accept a connection on port <port-number>(<errno>)

Explanation: While trying to accept a connection from a client, the accept failed on the listener port specified.

User Response: Check <errno> in the IBM UNIX System Services Message and Codes manual to determine the cause of the failure. If you are not able to determine what caused the error, contact Hiperstation for Mainframe Servers Customer Support.

TCPSSLTCPSSL-0082E REPLAY=r UNABLE TO PERFORM SSL HANDSHAKE WITH SERVER - CONNECTION=y - STATUS=st

Explanation: On an HTTPS connection Hiperstation for Mainframe Servers could not complete the SSL handshake processing with the server. Probable causes include:

• The server certificate is from an unknown certificate authority. Correct this by importing the appropriated certificate from the server.

• The key data base which Hiperstation for Mainframe Servers uses is not set up properly.• The SSLINFO DD statement, which contains the key data base name, and password is not

playback JCL.

User Response: Correct server certificate by importing the appropriate certificate from the server. For information on status (st), refer to the OS/390 System SSL Programing Guide and Reference.

VPCIVPCI204 MEMBER NOT FOUND

Explanation: The member name you specified was not found.

User Response: Check the spelling, and make sure the member exists.

Page 289: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-41

VPCI233 PDS AND/OR MEMBER DOES NOT EXIST

Explanation: The PDS and/or member name you specified was not found.

User Response: Check the spelling, and make sure the PDS and member exists.

VPCI241 THAT REDIRECT FILE IS CURRENTLY IN USE

Explanation: The redirect file you specified is in use.

User Response: Wait for the user/job to finish and try again.

VPCI341 LOG MEMBERNAME EXISTS, REPLACE=NO

Explanation: The member name you specified already exists, but you have REPLACE=NO.

User Response: Either specify REPLACE=YES, or use a different member name.

VPCI342 MEMBERNAME INVALID IN OTHER DSN FIELD

Explanation: You have specified a member name in the OTHER DSN field, which is invalid.

User Response: Specify a sequential DSN.

VPESVPES000 PLEASE ENTER A VALID DATASET NAME

Explanation: You have not specified a valid DSN.

User Response: Enter a valid DSN to continue.

VPES001 DATASET NAME NOT FOUND

Explanation: The dataset name you specified was not found.

User Response: Make sure the spelling is correct and the dataset exists.

VPES002 DATASET IS NOT A PDS DATASET

Explanation: The dataset you specified is not a PDS.

User Response: Specify a PDS and retry.

VPES003 PLEASE ENTER A VALID PDS MEMBER NAME

Explanation: You have not entered a valid PDS member name.

User Response: Specify a member name that exists and is spelled correctly.

VPES004 CONTROL MEMBER NOT FOUND; PLEASE MAKE ANY CHANGES AND PRESS ENTER TO CONTINUE

Explanation: The control member you specified was not found.

User Response: Check the spelling and make sure the member exists.

VPES005 CONTROL FILE NOT FOUND - CONTROL DATA WILL NOT BE SAVED. PLEASE MAKE ANY CHANGES AND PRESS ENTER TO CONTINUE

Explanation: The control file you specified was not found.

User Response: Check the spelling and make sure the file exists.

VPES006 ENTER NEW OUTPUT SCRIPT DATASET NAME. INPUT AND OUTPUT SCRIPT DATASET NAME MUST BE DIFFERENT

Explanation: You need to specify a valid output script DSN.

User Response: Specify a valid DSN that is different from the input DSN.

VPES007 NO SCRIPT MEMBERS SELECTED

Explanation: You have not selected any script members.

User Response: Select one or more script members to continue.

Page 290: Hiperstation Messages and Codes

6-42 Hiperstation Messages and Codes

VPES008 LINE COMMANDS ARE: S(SELECT) OR R(RENAME)

Explanation: The line command you entered is invalid.

User Response: Enter S to Select or R to rename.

VPES010 DUPLICATE MEMBER NAME FOUND - PLEASE ENTER A VALID PDS MEMBER NAME.

Explanation: The member you specified already exists.

User Response: Enter a new member name that does not already exist.

VPES013 INVALID COMMAND ENTERED. VALID COMMANDS ARE: ADD OR CURRENCY

Explanation: The command you specified is invalid at this time.

User Response: Use ADD or CURRENCY.

VPES014 INVALID COMMAND ENTERED. VALID COMMANDS ARE: ADD

Explanation: The command you specified is invalid at this time.

User Response: Use ADD.

VPES015 INVALID SCRIPT TYPE ENTERED. VALID SCRIPT TYPES ARE: 3270 OR ALL FOR ALL SCRIPTS

Explanation: The script type you specified is invalid.

User Response: Use 3270 or ALL for all scripts.

VPES016 INVALID MESSAGE TYPE ENTERED. VALID MESSAGE TYPES ARE: INPUT, OUTPUT, OR BOTH

Explanation: The message type you specified is invalid at this time.

User Response: Use INPUT, OUTPUT, or BOTH.

VPES018 REQUESTED ITEM NOT FOUND

Explanation: The requested item could not be found.

User Response: Make sure the spelling is correct and that the item exists.

VPES020 PLEASE ENTER A VALID CURRENCY NAME; 1 TO 3 CHARACTERS

Explanation: You need to enter a valid currency name.

User Response: Make sure the name contains 1 to 3 characters.

VPES021 PLEASE ENTER A VALID CURRENCY SYMBOL; 1 TO 3 CHARACTERS

Explanation: You need to enter a valid currency symbol.

User Response: Make sure the symbol contains 1 to 3 characters.

VPES022 PLEASE ENTER A "P"(PREFIX POSITION) OR A "S"(SUFFIX POSITION)

Explanation: A valid value is required.

User Response: Use a P for Prefix or an S for Suffix.

VPES024 PLEASE ENTER THE NUMBER OF DECIMAL POSITIONS (0-10)

Explanation: A valid value of decimal positions is required.

User Response: Use a number from 0 to 10.

VPES027 PLEASE ENTER A VALID ROW (1-43) OR COLUMN (1-132)

Explanation: Valid row and column values are required.

User Response: Use 1 to 43 for row and 1 to 132 for column numbers.

VPES028 PLEASE ENTER A VALID (ROW/COLUMN)

Explanation: Valid row and column values are required.

User Response: Enter valid row and column numbers.

Page 291: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-43

VPES030 PLEASE ENTER A VALID CURRENCY NAME TO PERFORM THE ACTION AGAINST

Explanation: A valid currency name is required to perform the action against.

User Response: Enter a valid currency name.

VPES033 DSN(&EUROIDSN) NOT ALLOCATED: DATASET IS IN-USE BY ANOTHER USER

Explanation: The dataset you specified is currently in use.

User Response: Try again when the user/job is finished.

VPES034 DSN(&EUROODSN) NOT ALLOCATED: DATASET IS IN-USE BY ANOTHER USER

Explanation: The dataset you specified is currently in use.

User Response: Try again when the user/job is finished.

VPES040 DSN(&EUROCDSN) NOT ALLOCATED: DATASET IS IN-USE BY ANOTHER USER

Explanation: The dataset you specified is currently in use.

User Response: Try again when the user/job is finished.

VPES041 DSN(&EUROMDSN) NOT ALLOCATED: DATASET IS IN-USE BY ANOTHER USER

Explanation: The dataset you specified is currently in use.

User Response: Try again when the user/job is finished.

VPES044 INVALID REPORT DATASET SPECIFIED. THE DATASET MUST BE DSORG=PS, RECFM=VBA, LRECL=133

Explanation: The report dataset you specified is invalid.

User Response: Make sure the dataset has DSORG=PS, RECFM=VBA, and LRECL=133.

VPES049 PLEASE ENTER A VALID HEX OFFSET. THE VALID RANGE IS 1 TO 8000.+

Explanation: A hex offset is required.

User Response: Use a number from 1 to 8000.

VPES050 THE CONTROL DATASET IS INVALID. THE DATASET MUST HAVE A MINIMUM LRECL=80 FOR A RECFM=F DATASET OR A MINIMUM LRECL=84 FOR A RECFM=V DATASET

Explanation: The control dataset you specified is invalid.

User Response: Use a dataset with at least LRECL=80 for RECFM=F and at least LRECL=84 for RECFM=V.

VPES051 THE CURRENCY DATASET IS INVALID. THE DATASET MUST HAVE A MINIMUM LRECL=80 FOR A RECFM=F DATASET OR A MINIMUM LRECL=84 FOR A RECFM=V DATASET

Explanation: The currency dataset you specified is invalid.

User Response: Use a dataset with at least LRECL=80 for RECFM=F and at least LRECL=84 for RECFM=V.

VPES052 VALID SPACE UNITS ARE: BLKS (BLOCKS), TRKS (TRACKS), CYLS (CYLINDERS), KB (KILOBYTES), MB (MEGABYTES), OR BYTES

Explanation: The space units you specified are invalid.

User Response: Use BLKS, TRKS, CYLS, KB, MB, or BYTES.

VPES055 INVALID COMMAND ENTERED. VALID COMMANDS ARE: LOCATE, TOP, OR BOTTOM

Explanation: The command you specified is invalid.

User Response: Use LOCATE, TOP, or BOTTOM.

VPES059 THE &EALCFTYP FILE MUST BE ALLOCATED AS A PDS OR PDSE FILE

Explanation: The file cannot be allocated as specified.

User Response: Make sure the file is allocated as a PDS or PDSE file.

Page 292: Hiperstation Messages and Codes

6-44 Hiperstation Messages and Codes

VPES060 THE RECORD FORMAT MUST BE "FB" OR "VB"

Explanation: The record format is invalid.

User Response: Use FB or VB.

VPES066 &SPI2MNME ALREADY EXISTS; PLEASE USE R(RENAME) WITH NEW MEMBER NAME.

Explanation: The member you specified already exists.

User Response: Enter a member name that does not already exist.

VPES067 NEW NAME MUST BE PROVIDED WITH R(RENAME).

Explanation: A new member name was not provided with the rename line-command.

User Response: Enter a name for the new member.

VTCSINTFVTCSINTF-0015W Cannot write create script for LU:luname without a valid Hiperspace file handle

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSINTF-0016E Error rewinding hiperspace file n for LU:luname, rc = x

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSINTF-0017E Error closing hiperspace file n for LU:luname rc = x

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSMAINVTCSMAIN-0001E Dynalloc of Request file failed, DSN: dataset name code=x, info code=y

Explanation: Dynamic allocation for the global record request file (dataset name) failed. Refer to IBM publications for dynamic allocate return and info codes.

VTCSMAIN-0002I Dynalloc of repository file failed, DSN: dataset name code=x, info code=y

Explanation: Dynamic allocation for the repository file (dataset name) failed. Refer to IBM publications for dynamic allocate return and info codes.

VTCSMAIN-0003E Open of repository file failed, DSN: dataset name code=x

Explanation: Open of the repository file (dataset name) failed. Refer to IBM publications for dynamic allocate return code.

VTCSMAIN-0006E Error allocating Hiperspace file rc = x

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSMAIN-0007W Error writing to the Hiperspace file rc = x

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSMAIN-008E Unable to allocate storage for control block, cannot continue.

Explanation: A request to allocate storage failed.

Page 293: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-45

User Response: Increase region size and rerun the script create request. If problem persists, contact Compuware Customer Support.

VTCSMAIN-0013I No start of session found for LU:luname

Explanation: Indicates no start of session record was found for LU luname in the input repository. Script is created with data available.

User Response: For multi-segment repositories, ensure all segments are processed in the script create request. If “Re-use repositories” was selected at record time, the beginning of the session may have been overwritten.

VTCSMAIN-0014I No end of session found for LU:luname

Explanation: Indicates no end of session record was found for LU luname in the input repository. Script is created with data available.

User Response: For multi-segment repositories, ensure all segments are processed in the script create request.

VTCSMAIN-0030I Script dataset: dataset name

Explanation: Indicates the script dataset (dataset name) specified in the global record request record specified for this script create request.

VTCSMAIN-0031I Conversation log dataset: dataset name

Explanation: Indicates the conversation log dataset (dataset name) specified in the global record request record specified this script create request.

VTCSMAIN-0032I Combined Detail dataset: dataset name

Explanation: Indicates the combined detail dataset (dataset name) specified in the global record request record specified this script create request.

VTCSMAIN-0033I Inbound Detail dataset: dataset name

Explanation: Indicates the inbound detail dataset (dataset name) specified in the global record request record specified this script create request.

VTCSMAIN-0034I Outbound Detail dataset: dataset name

Explanation: Indicates the outbound detail dataset (dataset name) specified in the global record request record specified this script create request.

VTCSMAIN-0035E Script Creation failed

Explanation: Script create did not complete.

User Response: Look for other messages to determine reason.

VTCSMAIN-0036I Script creation finished, n sessions processed

Explanation: The script creation request finished processing. The request processed n sessions.

VTCSMAIN-0037I No script dataset specified, cannot create scripts.

Explanation: No script dataset was specified in the global record request record.

User Response: Update the script create criteria in the global record request record and re-execute script create.

VTCSMAIN-0038E Unable to write script member, script create terminating.

Explanation: An error was encountered while writing a script member to the script PDS. Processing is discontinued.

User Response: Check other messages for reasons. Make corrections and re-run the script create request.

VTCSMAIN-0041E SCRIPT CREATE FAILED FOR LU=<luname> APPL=<applid> USERID=<userid> REASON: <reason>

Explanation: The script create job failed for the reason specified. Possible reasons are:

Page 294: Hiperstation Messages and Codes

6-46 Hiperstation Messages and Codes

• STOW macro failure• No directory space• x37 abend• Enqueue failure• Replace Members=no, and no unique members• No records recorded• 913 security abend• Unknown DCB abend exit abend• Datastream error• Could not allocate script dataset• Bad script characteristics.

VTCSMAIN-0042E INITIAL REPOSITORY FAILED TO OPEN >> JOB <jobname> (<jobnumber>)

Explanation: The script create job was unable to open the repository (the first repository if segmented). The repository file may be allocated to another job.

User Response: Create the script at a later time using Review Repository.

VTCSMAIN-0043I FOR MORE INFORMATION SEE JOB >> JOB <jobname> (<jobnumber>)

Explanation: An error occurred during script create that has already appeared on-screen. This message allows the user to refer to the actual script create job that failed.

User Response: View the specified job to diagnose the problem.

VTCSREADVTCSREAD-0009E While attempting to read file n for LU: luname the Hiperspace File Management array was fount not to be initialized

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSREAD-0010E Invalid file handle for Hiperspace File n for LU: luname

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSREAD-0011E Hiperspace File n for LU:luname is marked as not in use

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSREAD-0012E Hiperspace file n for LU: luname is not opened

Explanation: Internal error.

User Response: Contact Compuware Customer Support.

VTCSSRCHVTCSSRCH-0070W No data found for specified Date/Time range

Explanation: The archive has no data within the time range specified.

User Response: Correct the time range and try again.

VTCSSRCH-0071E Error processing repository segment, no VSBE found

Explanation: A control block in the archive cannot be found.

User Response: Call Hiperstation for VTAM Customer Support.

VTCSSRCH-0072E Dynalloc of Registry file failed, DSN: xxx -code=xxx, info code=xxx

Explanation: A registry file could not be allocated.

Page 295: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-47

User Response: Check security permissions and disk space and retry.

VTCSSRCH-0073E Invalid repository set specification: xxx, must end with .#*

Explanation: The archive set does not adhere to naming standards.

User Response: Correct and retry.

VTCSSRCH-0074E Unable to create message log member

Explanation: The log member could not be allocated.

User Response: Check security permissions and disk space and retry.

VTCSSRCH-0075E Error reading from xxx hiperspace, rc=xxx

Explanation: The hiperspace file could not be accessed.

User Response: Call Hiperstation for VTAM Customer Support.

VTCSSRCH-0076E Unable to open xxx dataset

Explanation: The specified dataset could not be accessed.

User Response: Check security permissions and disk space and retry.

VTCSSRCH-0077E Locate within Registry failed, rc=xxx (type=xxx)

Explanation: The time range within the registry could not be located.

User Response: Call Hiperstation for VTAM Customer Support.

VTCSSRCH-0078E Error reading from xxx dataset, rc=xxx

Explanation: The specified dataset could not be accessed.

User Response: Check security permissions and retry.

VTCSSRCH-0079E Error reading from xxx dataset, unexpected End-of-File

Explanation: The specified dataset appears to be incomplete.

User Response: Call Hiperstation for VTAM Customer Support.

VTCSSRCH-0080E Global Record Request Record (Filtering) not found

Explanation: The filter information could not be located within the request.

User Response: Call Hiperstation for VTAM Customer Support.

VTCSSRCH-0081E Error removing temp dataset xxx

Explanation: Temporary file cleanup could not be completed.

User Response: Check security permissions and retry.

VTCSSRCH-0082E Error creating pathname xxx, rc=xxx Error text: <errno_explanation by peror() function>

Explanation: The specified pathname could not be accessed.

User Response: Check security permissions and disk space and retry.

VTCSSRCH-0088I Parm SSKIPLU0 indicates to not attempt formatted search on LU type 0 terminals.

Explanation: Informs user that no attempt will be made to format and search any LU type 0 sessions found in the archive within the search timeframe. This behavior is controlled by installation parameter SSKIPLU0.

User Response: None.

VTCSSRCH-0089I Session for LU type 0 terminal(aaaaaaaa) not searched.

Explanation: Informs user that an LU type 0 sessions was found within the archive, but no attempt was made to format and search that sessions data.

User Response: None.

Page 296: Hiperstation Messages and Codes

6-48 Hiperstation Messages and Codes

VTCSSRCH-0090E Error on attempted write to file xxx

Explanation: There was an error writing the indicated file to HFS. This message can indicate a full HFS volume or a security violation. This message will be accompanied by a VTCSSRCH-0091I message, which contains the complete path of the file that failed.

User Response: Determine the cause of the error on the HFS file. If the search is generating a large number of hits, search criteria may need to revised.

VTCSSRCH-0091I /xxx/ ... /xxx

Explanation: This message appears along with a VTCSSRCH-0090E or VTCSSRCH-0095E error message and provides the complete path to the file associated with these error messages.

User Response: Informational message, see associated error message for more details.

VTCSSRCH-0092E Unable to rename xxx to xxx

Explanation: An attempt to rename an HFS file failed.

User Response: Verify that the HFS volume is not full and the user attempting to rename the related file has the proper authority.

VTCSSRCH-0093E Unable to restore xxx from xxx

Explanation: An attempt to restore index.xml was unsuccessful.

User Response: The related archive search index.xml file may be empty, missing, or corrupted. Determine the cause of the error on the HFS file and restore index.xml from index.back.

VTCSSRCH-0094I Successfully restored xxx from xxx

Explanation: An error occurred while working with the index.xml, file but it was successfully restored from the backup.

User Response: None. Recovery was successful.

VTCSSRCH-0095E Error on attempted creation of file xxx

Explanation: An attempt to allocate an HFS file failed. This message will be accompanied by a VTCSSRCH-0091I message, which contains the complete path of the file that failed.

User Response: Determine the cause of the error on the HFS file. If the search is generating a large number of hits, search criteria may need to revised.

VTCSSRCH-0096E Error writing one or more files related to the report

Explanation: The archive search was unable to write one or more files related to the search. The search has been terminated.

User Response: Check previous error messages for additional details.

VTCSSRCH-0097I Removing directory: xxx

Explanation: An HFS error occurred while creating the report, and the report was in an incomplete state. The incomplete report was removed.

User Response: Check previous error messages for additional details.

VTCSSRCH-0100S Cannot connect to SIEM tool at address=<siem-ip-address> and port=<siem-port>

Explanation: Hiperstation cannot connect to the SIEM tool.

User Response: Ensure that the IP address and port are accurate and that the SIEM tool is able to accept TCP connections.

VTCSSRCH-0101S Unable to send data to SMF because records of SMF type <smf-record-number> and subtype <smf-record-number-subtype> are not being captured.

Explanation: Hiperstation is unable to write SMF records with data for SIEM tool.

User Response: Ensure that the correct SMF record number was specified or that SMF is configured to write SMF records of the record number specified. Also, the Hiperstation load library needs to be APF authorized.

Page 297: Hiperstation Messages and Codes

Hiperstation Messages: TCPAR through VTCSUTIL 6-49

VTCSSRCH-0102I <hiperstation-data-type> data will be written to SMF type <smf-record-number> and subtype <smf-record-number-subtype> records.

Explanation: Hiperstation is writing SMF records with SIEM data of the specified SMF record number and subtype.

User Response: None.

VTCSSRCH-0103I <hiperstation-data-type> data will be sent to address=<siem-ip-address> and port=<siem-port>.

Explanation: Hiperstation is writing records to the SIEM tool.

User Response: None.

VTCSSRCH-0104S Unable to write <hiperstation-data-type> data to dataset <siem-dataset>. Reason: <reason>

Explanation: Hiperstation is unable to write SIEM data for the reason specified.

User Response: Based on the reason specified, make the appropriate correction to the dataset.

VTCSSRCH-0105I Writing <hiperstation-data-type> data to dataset <siem-dataset>.

Explanation: Hiperstation is writing SIEM data to the specified dataset.

User Response: None.

VTCSSRCH-0106S Cannot write SMF records. Reason: <reason>

Explanation: Hiperstation is unable to an write SMF record.

User Response: Based on the reason, make the appropriate correction.

VTCSSRCH-0107S Unable to write <siem-destination> record. Return Code: <return-code> Reason Code: <reason-code>.

Explanation: Hiperstation was unable write the SIEM data.

User Response: Consult IBM’s UNIX System Services Messages and Codes for an explanation of the return code and reason code. Make the appropriate corrections based on those values.

VTCSSRCH-0108E Connection to SIEM tool failed. Error Code: <return-code>

Explanation: Hiperstation failed to connect to the SIEM tool.

User Response: Based on the reason specified, correct the issue.

VTCSSRCH-0109S Invalid value of <value> for SIEM Destination specified. Valid values are 1 (TCP), 2 (SMF), or 3 (dataset).

Explanation: An invalid value was specified for the Hiperstation parameter.

User Response: In Hiperstation customization, correct the value.

VTCSSRCH-0110S Value of [<value>] is invalid for ETRMGPAR parameter <etrmgpar-parameter>

Explanation: An invalid value was specified for the Hiperstation parameter.

User Response: In Hiperstation customization, correct the value.

VTCSSRCH-0111I Writing Type <smf-record-number> subtype <smf-record-number-subtype> SMF records

Explanation: Hiperstation is writing SMF records with SIEM data of the specified SMF record number and subtype.

User Response: None.

VTCSSRCH-0112E An error occurred write to TCP socket. Reason: <reason>

Explanation: Hiperstation failed to write to the TCP socket to connect to the SIEM tool.

User Response: Based on the reason specified, correct the issue.

VTCSSRCH-0113E An error occurred trying to create TCP socket Reason: <reason>

Explanation: Hiperstation failed to create the TCP socket to connect to the SIEM tool.

Page 298: Hiperstation Messages and Codes

6-50 Hiperstation Messages and Codes

User Response: Based on the reason specified, correct the issue.

VTCSSRCH-0114W Failed to load SIEM exit program <siem-exit-program>.

Explanation: The exit program specified during Hiperstation customization was not found. The SIEM data will still be sent to the SIEM tool with Hiperstation’s default information.

User Response: Ensure the program name specified in Hiperstation customization is correct and that the program was link-edited into the Hiperstation load library.

VTCSSRCH-0115I Exit program <siem-exit-program> has been loaded.

Explanation: The exit program specified during Hiperstation customization was found and loaded.

User Response: None.

VTCSSRCH-0116E The XML returned by exit program <siem-exit-program> failed XML verification Return Code: <return-code> Reason Code: <reason-code> Returned XML: <xml>

Explanation: The XML returned by the user exit program is invalid XML. Hiperstation will not send the data to the SIEM tool.

User Response: Consult IBM’s XML System Services User’s Guide and Reference manual for an explanation of the return code and reason code. Make the appropriate corrections to the specified user exit.

VTCSUTILVTCSUTIL-0018E Request record type = "a" is not a VTAM type. Cannot create VTAM scripts

Explanation: Global record request record specified is not for 3270 or APPC activity.

User Response: Contact Compuware Customer Support.

VTCSUTIL-0019I Allocated repository file dataset name

Explanation: Indicates name of dataset opened for repository.

VTCSUTIL-0020I Starting pass # n through repository

Explanation: Indicates current number of passes through the repository. Multiple passes may be needed to process large numbers of sessions. To reduce or eliminate excess passes in Script Create or Audit Search, review the MXHIPRFL parameter in the Hiperstation Installation and Configuration Guide.

VTCSUTIL-0022E Global record request record not found

Explanation: The Global record request record specified for script creation was not found on the global record request file.

User Response: Ensure the script creation task is using the correct global record request file.

VTCSUTIL-0023E Unable to open global record request file DSN = dataset name

Explanation: The script creation task could not open the Global record request file.

User Response: Ensure the script creation task is using the correct global record request file.

VTCSUTIL-0024E Dynalloc failed with error code = x, info code = y, DSN: dataset name

Explanation: Dynamic allocation for (dataset name) failed. Refer to IBM publications for dynamic allocate return and info codes.

VTCSUTIL-0025I Deallocate failed with error code = x, info code = y DSN: dataset name

Explanation: Deallocation for the specified dataset (DSN) failed.

User Response: Refer to IBM publications for dynamic deallocate return and information codes.