hilti seismic epaq hels inki 2009 i xst/et · hilti seismic epaq hels inki 2009 i xst/et 3 •...

87
Hilti Seismic EPAQ Helsinki 2009 I XST/et 1 www.hilti.com

Upload: others

Post on 10-Mar-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 1www.hilti.com

Page 2: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 2www.hilti.com

Seismic Performanceof Sheet Metal Deck

Hilti CorporationDr.-Ing. Thomas Engleder

Page 3: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 3www.hilti.com

• Introduction• Hilti – Company Overview

• Direct Fastening Technology

• Motivation

• Sheet Metal Decking in North America

• Shear Diaphragm Design

• Shear Diaphragm Testing Facility

• Seismic Behavior of Fastening Points and of Shear Diaphragms

• Summary and Outlook

Agenda

Page 4: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 4www.hilti.com

HiltiCompany Overview

Page 5: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 5www.hilti.com

● Founded in 1941 in Schaan, Principality of Liechtenstein

● One of the global leading companies in providing products, systems and services to construction professionals

● Located in more than 120 countries on five continents

● More than 21,000 employees● More than 50 nationalities at Group

Headquarters in Schaan● Direct sales model● 2003 winner of the Carl Bertelsmann

Prize for outstanding corporate culture

Hilti – a worldwide presence

Page 6: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 6www.hilti.com

Core Trades – Overview

Building construction Civil engineering Mechanical installation

Steel and metal Interior finishing Electrical installation

Page 7: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 7www.hilti.com

Fabrication and installation of handrails, stairs, fences, balconies, etc.

Manufacturing & installation of steel structuresFastening steel columns to base

Installation of roofsInstallation of decksInstallation of metal façadesFlat roof insulation

Installation of glass façadesInstallation of frames (windows, doors,…)

Structural Steel Fabrication &

Erection

Roofing / Siding, Sheet Metal, Flat Roof Insulation

Metal Frames,Glas Facades

Metal Work and Other Steel

Steel/Metal Key Applications

Page 8: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 8www.hilti.com

Direct Fastening Technology

Page 9: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 9www.hilti.com

Direct Fastening (DX) Technology

• Powder or gas actuated nailing• Fastening in concrete and steel• No drilling required

Page 10: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 10www.hilti.com

Hilti Piston Principle (no shooting)

• 5 tons of weight• ~60 m/s• one millisecond• 1.5 MW (2,000 hp)• 100…400 J

Page 11: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 11www.hilti.com

Anchoring in steel

• Nail displaces steel volume –deformation, friction

• Strong heating of contact zone surface reactions, local welding and brazing

• Local positive locking (knurled surface of nail)

Page 12: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 12www.hilti.com

Motivation

Page 13: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 13www.hilti.com

Motivation

• Hazard analysis (e.g. earthquakes) gets increased importance.

• Building codes allow reduced seismic loads, provided that the structure is adequately designed as a ductile (energy dissipating) seismic load resisting system (SLRS).

• Many single story buildings are built using a steel roof shear diaphragm, which could then also be used as a SLRS.Currently thick deck is required to fulfill the requirements.

• Mechanical fasteners are key elements in these constructions.

• In the US welding of sheet metal deck is still common practice (~90%).In Canada a significant shift to mechanical fastener is observed.Hilti drives and supports this development also in the US.

• A detailed understanding and analysis of shear diaphragms in general together with optimized fastening technologies allow for a more cost efficient design of structures.

Page 14: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 14www.hilti.com

Sheet Metal Decking inNorth America

http://www.us.hilti.com/decking

Page 15: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 15www.hilti.com

Application – Roof Deck Diaphragm on Bar Joists

Page 16: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 16www.hilti.com

Application – Roof Deck Diaphragm on Bar Joists

Page 17: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 17www.hilti.com

Application – Consumables and Tools

bar joist / support

X-ENP19 X-EDNK22 X-EDN19

DX 860 HSN/ENP ST 1800 + SDT 30

S-SLC 01/02 HWH

Page 18: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 18www.hilti.com

Current Fastening Technology: Welding

welds

Page 19: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 19www.hilti.com

High performing Sheet Metal Fastening Systems

Page 20: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 20www.hilti.com

Shear Diaphragm Design

Page 21: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 21www.hilti.com

Design Codes

• IBC (International Building Code)

• ICC-ES AC43 (International Code Council Evaluation Service)

• SDI DDM 03 (Steel Deck Institute Diaphragm Design Manual)

• TM 5-809 Seismic Design of Buildings (Tri-Services Manual)

• ASCE 7 (American Society of Civil Engineers)

• AISC (American Institute of Steel Construction)

• AISI Specification (American Iron and Steel Institute)

• CSA S16 (Canadian Standards Association)

• Eurocode 8

• ….

Page 22: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 22www.hilti.com

Application – Structural Design for Shear

~90%

Page 23: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 23www.hilti.com

Roof Deck Diaphragm Model (SDI)

(SDI = Steel Deck Institute)

Page 24: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 24www.hilti.com

Structural Design for Shear – SDI Approach

e.g. pin performance Qf

e.g. screw performance Qs

Lap shear test data System shear resistancecalculated by adding up

the pin & screwperformance Qf and Qs

Generic formula(allows any combination

of fasteners)(SDI = Steel Deck Institute)

Page 25: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 25www.hilti.com

Structural Design for Shear – SDI Approach

In general, the design is commonly done using design tables for maximum nominal loads supplied by SDI and deck manufacturers.The performance is based on analytical calculations or on test results.

<= earthquake

Page 26: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 26www.hilti.com

AISC Seismic Design - LoadsV = basic seismic base shear load

R = Response Modification Coefficient (reduction factor for applied lateral force)

Page 27: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 27www.hilti.com

AISC Seismic Design

[ Source: AISC Seismic Design Manual, 2006 ]

Response ModificationCoefficient

(reduction factor for applied lateral force, greater deformation capacity)

Page 28: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 28www.hilti.com

Shear Diaphragm Testing FacilityTesting according to ICC-ES AC43 and AISI S907

Page 29: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 29www.hilti.com

Fastening Systems Research LaboratoryCorporate Research & Technology

US-nat.

accred.

council for

LabAccred.

worldwide internat. lab. accred. cooperation

DAP-PL-4106.00

Hilti Test Lab Accreditation

Page 30: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 30www.hilti.com

Test Rig Building (Schaan Hilti HQ)

Page 31: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 31www.hilti.com

Test Frame

Page 32: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 32www.hilti.com

Test Frame – Technical Data

size: 8 x 10 m (24’ x 30’)

variable spans: 1.6, 2.5, 3.3 m (5’ , 7’-6” , 10’)

variable support thickness

static maximum load 700 kN (157’000 lbs)maximum deflection 200 mm (8 inch)

dynamic maximum load 370 kN (90’000 lbs) maximum deflection +/-200mm (8 inch)

Page 33: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 33www.hilti.com

Operating Principle (shear load)

Page 34: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 34www.hilti.com

Quasi Static and Seismic Test Setup

Page 35: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 35www.hilti.com

Seismic/Cyclic Behaviourof Fastening Points under Shear

Page 36: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 36www.hilti.com

Source: Hilti, BGVB internal report, 1992

Steel Deck Frame Fastener under Cyclic Loading

Page 37: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 37www.hilti.com

Steel Deck Frame Fasteners after Cyclic Loading

Source: INELASTIC SEISMIC RESPONSE OF METAL ROOFDECK DIAPHRAGMS FOR STEEL BUILDING STRUCTURES. Hesham S. Essa, Robert Tremblay and Colin A. Rogers, 12th European Conference on Earthquake Engineering, Paper Reference 482

Weld Screw Powder-Actuated

Page 38: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 38www.hilti.com

Seismic Performanceof Shear Diaphragms

Page 39: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 39www.hilti.com

Seismic Test Setup

Page 40: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 40www.hilti.com

Quasi Static and Seismic Test Setup

4572

4572

Load introduction

2286

2286

9144

C

DB

7315,2

A

Bea

m 1

1

Bea

m 1

0

Beam 9

Beam 5

Beam 1

Beam 7

Beam 3

2286

2286

Page 41: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 41www.hilti.com

Seismic Test – Load Protocol

[curve definition by R. Tremblay]

Page 42: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 42www.hilti.com

1. StepQuasi Static Pre-TestingTest Results & Failure Modes

Page 43: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 43www.hilti.com

Example (Quasi Static Pre-Test)

Page 44: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 44www.hilti.com

Controlling Modes

Decking• Global buckling• Local buckling

Page 45: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 45www.hilti.com

Controlling modes

Frame Fasteners in shear● Slotting of sheeting due to shear ● Pullout ● Fracture

Page 46: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 46www.hilti.com

Controlling Modes Frame Fasteners in tension

• Pullout (predominantly at the end-overlap)

Page 47: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 47www.hilti.com

Controlling Modes Sidelap screws

• Tilting, slotting, piling up• Fracture

Page 48: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 48www.hilti.com

2. StepSeismic Testing

Page 49: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 49www.hilti.com

Seismic Test – Load Protocol

[curve definition by R. Tremblay]

Page 50: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 50www.hilti.com

Seismic Test Video

University of Montreal, R. Tremblay

Hilti AG Schaan, FSRL, DFC project

[1:45 / 2:55]

Co-operation partner

Page 51: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 51www.hilti.com

Seismic/Cyclic Test Result

cyclic load

X-ENP19@36s7_#12@12_20ga_1/4_5

SDI allowable service load

Page 52: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 52www.hilti.com

Observed Failure

Page 53: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 53www.hilti.com

Observed Failure

Page 54: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 54www.hilti.com

Seismic/Cyclic Test Result

cyclic loadquasi static capacityremaining capacity

X-ENP19@36s7_#12@12_20ga_1/4_5

SDI allowable service load

Page 55: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 55www.hilti.com

Seismic/Cyclic Test Energy Dissipation

Page 56: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 56www.hilti.com

Test ReproducibilityIdentical tests lead

to same results!

Page 57: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 57www.hilti.com

Cyclic protocolCyclic protocol: Ram displacement

Test S 07 and S 08 based on pretest # 63

-140-120-100-80-60-40-20

020406080

100120140

0 30 60 90 120 150 180 210 240 270 300 330

Time (s)

Ram

dis

plac

emen

t [m

m]

Page 58: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 58www.hilti.com

Seismic Test Scope

Page 59: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 59www.hilti.com

Seismic Load-Deflection Behaviour

Page 60: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 60www.hilti.com

Seismic Test Results

Page 61: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 61www.hilti.com

Summary & Outlook

Page 62: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 62www.hilti.com

Summary and Outlook

• Sheet steel shear diaphragms fastened with mechanical fasteners (nail, screws, etc.) show a ductile behavior under cyclic/seismic loading.

• All tests done show that the remaining diaphragm performance after cyclic/seismic loading exceeds the allowable service load.

• Further testing and analysis in currently ongoing.

• Expectation: Research activities will lead to design provisions, providing the necessary structural safety with the possibility of thinner sheet metal deck, allowing for a lighter, more economical design.

Page 63: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 63www.hilti.com

Thankyou!

Page 64: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 64www.hilti.com

Page 65: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 65www.hilti.com

Page 66: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 66www.hilti.com

Key figures for 2007

Sales

Operating result

Net income

Expenditures for researchand development

Employees worldwide (average)

CHF

CHF

CHF

CHF

4,667 million

533 million

422 million

177 million

18,930

Page 67: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 67www.hilti.com

We create enthusiasm through innovation

● We want our customers to work efficiently and safely.● We anticipate their future needs by looking over their shoulder.● This is how we discover possibilities for innovation and develop new

and high-quality products.

Page 68: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 68www.hilti.com

0306090

120150180210240

2005 2006 2007

Research and development expenses

151177

164

In CHF million

Page 69: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 69www.hilti.com

Page 70: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 70www.hilti.com

Hilti Siding & Decking Direct Fastening Selector

Page 71: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 71www.hilti.com

Hilti Siding & Decking Direct Fastening Selector

Page 72: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 72www.hilti.com

Page 73: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 73www.hilti.com

Software Tools – Profis DF / Profis DF Dia

Page 74: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 74www.hilti.com

Page 75: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 75www.hilti.com

Direct fastening: products for decking

High performance deck fastening systems

DX 860-ENP DX 76 PTR

X-ENP

X-EDNK

SDT 30 & ST 1800

S-MS (Speedy screw)

Page 76: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 76www.hilti.com

Innovative system solutions

Page 77: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 77www.hilti.com

Page 78: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 78www.hilti.com

Terminology

Page 79: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 79www.hilti.com

Deck Attachment with Arc Spot Welds

• Traditional / Low Cost Material• Quality control highly variable• Slow production rate• Health risks – toxic fume exposure• Weather dependent (rain/snow)• Back stress / worker comp injuries• Deck coating & paint burn-off• Requires 2nd step corrosion protection• Visible vs. effective diameter• Problems with multi-layer thick deck

Page 80: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 80www.hilti.com

Page 81: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 81www.hilti.com

Application – Metal deck fastening

Page 82: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 82www.hilti.com

Fastening of 4 sheet metals

Cross-section of fastening

• Prediction of sheet deformation• Optimization of nail geometry• Analysis of loads on tool and piston• Evaluation of driving forces

Page 83: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 83www.hilti.com

Behavior of Roof Deck Diaphragms under Quasi-static Cyclic LoadingJ. Struct. Engrg. Volume 129, Issue 12, pp. 1658-1666 (December 2003) Issue Date: December 2003 Hesham S. Essa1, Robert Tremblay2 and Colin A. Rogers3

1Post-Doctoral Research Associate, Dept. of Civil, Geological, and Mining Engineering, Ecole Polytechnique, Montreal PQ, Canada H3C 3A7. 2 Professor, Dept. of Civil, Geological, and Mining Engineering, Ecole Polytechnique, Montreal PQ, Canada H3C 3A7. 3 Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal PQ, Canada H3A 2K6.

A series of 18 large-scale tests was carried out on corrugated cold-formed steel deck diaphragms for single-story buildings to investigate the diaphragm's ability to function as the main source for absorbing earthquake induced energy through inelastic behavior. Tests were performed using a cantilever type configuration for the test setup, in which the steel deck was laid in a horizontal plane. Diaphragm assemblies made with 0.76 and 0.91 mm thick metal deck sheets and with nine combinations of deck-to-frame and deck-to-deck (side lap) fasteners were tested. For each fastening combination, two tests were conducted: monotonic and quasistatic cyclic. Both the strength and failure modes under quasistatic cyclic loading are different from those under monotonic loading. Test results indicate that diaphragms with welded deck-to-frame fasteners without washers have limited ductility and cannot sustain cyclic loading at relatively large displacement amplitudes. The use of mechanical and welded-with-washer deck-to-frame fasteners enhances the strength, ductility and energy dissipation characteristics of the diaphragm considerably.

© 2003 American Society of Civil Engineers

Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners

Page 84: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 84www.hilti.com

Inelastic Seismic Response of Frame Fasteners for Steel Roof Deck DiaphragmsJ. Struct. Engrg. Volume 129, Issue 12, pp. 1647-1657 (December 2003) Issue Date: December 2003Colin A. Rogers1 and Robert Tremblay2

1Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal QC, Canada H3A 2K6. 2Professor, Dept. of Civil, Geological and Mining Engineering, École Polytechnique, Montreal QC, Canada H3T 1J4.

An experimental program was undertaken to investigate the inelastic seismic response of metal deck roofing systems. The load carrying capacity of roof diaphragms for low-rise steel buildings, subjected to lateral loads from wind and/or earthquakes, is directly dependent on the performance of the connections. This paper provides information on the inelastic cyclic response, including load versus displacement hysteresis and energy absorption capacity of 144 deck-to-frame screwed, powder-actuated fastener, and welded connection tests for different steel deck and structure thickness. Powder-actuated fastenerconnections were able to provide the highest energy dissipation results, followed closely by screwed connections. In many cases, the welded connections exhibited significant ultimate capacities, but failed at small displacements, resulting in low energy dissipation values. However, when welds with washers were used, the ductility and energy absorption ability of the connection were substantially improved.

© 2003 American Society of Civil Engineers

Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners

Page 85: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 85www.hilti.com

Inelastic Seismic Response of Frame Fasteners for Steel Roof Deck DiaphragmsJ. Struct. Engrg. Volume 129, Issue 12, pp. 1647-1657 (December 2003) Issue Date: December 2003Colin A. Rogers1 and Robert Tremblay2

1Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal QC, Canada H3A 2K6. 2Professor, Dept. of Civil, Geological and Mining Engineering, École Polytechnique, Montreal QC, Canada H3T 1J4.

…. This paper provides information on the inelastic cyclic response, including load versus displacement hysteresis and energy absorption capacity of 144 deck-to-frame screwed, powder-actuated fastener, and welded connection tests for different steel deck and structure thickness. Powder-actuated fastenerconnections were able to provide the highest energy dissipation results, followed closely by screwed connections. In many cases, the welded connections exhibited significant ultimate capacities, but failed at small displacements, resulting in low energy dissipation values. …

© 2003 American Society of Civil Engineers

Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners

Page 86: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 86www.hilti.com

Hilti Test Lab Accreditation

Page 87: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation

Hilti Seismic EPAQ Helsinki 2009 I XST/et 87www.hilti.com

Seismic Zones