hill-rom® versacare® bed tips simply effective

18
1 FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE VERSACARE® BED, SEE USER’S MANUAL. Hill-Rom® VersaCare® Bed Tips Simply Effective

Upload: others

Post on 26-Dec-2021

6 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Hill-Rom® VersaCare® Bed Tips Simply Effective

1

FOR COMPLETE INSTRUCTIONS ON HOW TO OPERATE THE VERSACARE® BED, SEE USER’S MANUAL.

Hill-Rom®VersaCare® Bed TipsSimply Effective

Page 2: Hill-Rom® VersaCare® Bed Tips Simply Effective

2

• Allowsthecaregivertocustomizetheoveralllengthofthebedandsleepsurfacetofitthepatient.

• Thebedandsurfacecanberetractedupto11"(28cm)whichalsoaidsthecaregiverduringtransport(i.e.smallelevators,smallerturningradius).

• Helpsreducepatientmigrationtothefoot-endofthebed.

• IntegratedsurfaceautomaticallyadjuststothelengthofthebedasFlexAfoot™mechanismisactivated.

To Activate:• PressandholdthefootShortercontrolto

retractthefootsection.• PressandholdthefootLongercontrolto

extendthefootsection.

FlexAfoot™Mechanism

Longer

Shorter

Longer

Shorter

Page 3: Hill-Rom® VersaCare® Bed Tips Simply Effective

3

• Ifusinganintegratedairsurface(VersaCareA.I.R.®orVersaCare®P500),thesurfaceautomaticallygoesintoMaxInflatefor30minuteswhenCPRorEmergencyTrendelenburgisactivated.After30minutes,thesurfacewillgointoNormal/Standardmode.

• Acardiacarrestboardisrequired.Theheadboardcanbeusedinplaceofthecardiacarrestboard.

To Activate:• Pullandholdthehandle.• Holdthehandleuntiltheheadandknee

sectionscometoastopintheflatpositionandthefootsectionstopsraising.

• Releasethehandle.To Activate Emergency Trendelenburg:

• Pullandholdthehandle.• Holdthehandleuntiltheheadandknee

sectionscometoastopintheflatpositionandthefootsectionstopsraising.

• Continuetoholdthehandleuntilthedesiredangleisreached(upto15°).

OneStep®CPR&EmergencyTrendelenburg

Page 4: Hill-Rom® VersaCare® Bed Tips Simply Effective

4

• Ifyourpatientneedstoberepositioned,usetheBoost®featuretomakeiteasierforyoubyplacingthebedintheidealpositiontorepositionyourpatient.

• PressingtheBoost®buttonwill:-MaxInflatethemattress-Flattenthebed-Putthebedattheidealworkingheight-Placethebedin7°ReverseTrendelenburg

PatientRepositioning–Boost®Function

Boost™

To Activate:• PresstheBoost®buttononthesiderail.

To Deactivate:• PresstheBoost®buttontoreturnthebed

toflatposition.

Page 5: Hill-Rom® VersaCare® Bed Tips Simply Effective

5

Thebedexitalarmwillnotifythecaregiverwhen:

• OutofBed:patient’sweightshiftssignificantlyofftheframeofthebed.

• Exiting:patientmovesawayfromthecenterofthebedtowardsanegresspoint.

• PatientPosition:patientmovestowardeithersiderailormovesawayfromtheheadsection,suchassittingupinbed.

To Activate:• Ensurepatientisonthebed.• Presstheenablecontrol.• Pressthedesiredmodecontrol.Whenthe

systembeepsonetimeandtheindicatorlightstayson,thesystemisarmed.

To Deactivate:• PresstheEnableControl.• Pressthedesiredmodecontrol.Whenthe

systembeepsonetimeandtheindicatorlightisgone,thesystemisdeactivated.

BedExitAlarm–3ModePatientPositionMonitor

Page 6: Hill-Rom® VersaCare® Bed Tips Simply Effective

6

• Thescaleshouldbezeroedpriortoplacingapatientonthebed.

• BesuretoputALLlinens,pillows,andequipmentonthebedpriortozeroingthescale.

How to Zero the Scale:• PresstheEnableControl.• PressandholdtheZeroControluntil00.0

isshown.• (HOLDwillbedisplayeduntil00.0is

shown)andthenreleasethecontrol.• NOTE:Afterreleasingthecontrol,thescale

displaywillshow‘CALC’.Donottouchthebeduntilthedisplaystopsflashing‘CALC’andshows0.0.

ZeroingtheScale

Page 7: Hill-Rom® VersaCare® Bed Tips Simply Effective

7

• Besurethescalehasbeenzeroedwithlinens,pillows,andotherequipmentonthebedpriortoweighingthepatient.

How To Weigh A Patient:• Makesurethepatientiscenteredonthe

bed.• Ensurethebedisclearofallobstructions

(lines,tubing,walls,etc.).• Presstheweighbutton.• Onreleaseoftheweighcontrol,thebed

getsthecurrentpatient’sweight.Itisshowninlbsfor10seconds,thenkgfor5secondsandthenrepeats.

WeighingAPatient

Page 8: Hill-Rom® VersaCare® Bed Tips Simply Effective

8

• Allowsforthepatient’slegstobeplacedabovetheleveloftheirsternum.

To Activate:• Lowertheheadsectiontothedesired

position.• Raisethekneesectiontothedesired

position.• UsetheTrendelenburgcontroltoposition

thesleepdecktothedesiredposition.To Deactivate:

• UsetheReverseTrendelenburgcontroltoreturnthebedframetothehorizontalposition.

• Usethebedflattoreturnthesleepdecktotheflatposition.

VascularPosition

Page 9: Hill-Rom® VersaCare® Bed Tips Simply Effective

9

• Footpedalsallowthecaregivertoraiseandlowertheheadofthebedandtheheightofthebedwithoutusingtheirhands.

To Activate:• Stepdownonanypedalfor1-3seconds.• Releasethepedal.• Stepdownonthepedalofthedesired

functionuntilthedesiredfunctionisachieved.

HandsFree®FootPedals

Bed Up/Down

Head Up/Down

Page 10: Hill-Rom® VersaCare® Bed Tips Simply Effective

10

• Locatedonthecaregiversiderailcontrolpanel,thelockoutcontrolsallowthecaregivertodisablethebedarticulatingfunctionstopreventpatientpositioningfeaturesfrombeingused.

• Featuresthatcanbelockedout:-Bedhigh/low-Headup/down

To Activate:• SimultaneouslypresstheLockbuttonand

thespecificlockoutcontroldesired(eitherupordown).

• Bothpatientandcaregivercontrolsarelockedout.

• Anaudiblealarmsoundswhenalockoutisactivated.

• Anamberlightwillilluminateonthelockforthefeaturethatyouwantlockedout—thissignifiesthatthefeatureislockedout.

To Deactivate:• SimultaneouslypresstheLockbuttonand

thespecificlockoutcontroldesired(eitherupordown).

• Anaudiblealarmsoundsandtheamberlightdisappearswhenalockoutisdeactivated.

LockoutControls

Longer

Shorter

Longer

Shorter

Lock button

-Kneeup/down-Adjustablebedlength

Page 11: Hill-Rom® VersaCare® Bed Tips Simply Effective

11

• Visuallyconfirmthehead-of-bediselevated30degreesorhighertocomplywithprotocols.

• HOBanglealarmcanbeeasilysettonotifycaregiversiftheHOBisloweredlessthan30°.

To Activate:• Raisethehead-of-bedabove30°.• PresstheEnableKey.• Pressthe30°head-of-bedbutton.The

greenbuttonwilllightuptoindicatethealarmhasbeenset.

To Deactivate:• PresstheEnableKey.• Pressthe30°head-of-bedbutton.The

greenindicatorwillgooff.

Head-of-Bed(HOB)AngleAlarm

Page 12: Hill-Rom® VersaCare® Bed Tips Simply Effective

12

• Assistswithturningthepatientforlinenchanges,dressingchanges,bedpanning,backcareandothernursingprocedures.

• SiderailsmustbeintheuppositiontoactivateTurnAssist.

• OnceTurnAssistisinitiated,youmaylowerasiderailtofacilitatepatientcare.

• Thebedwillalarmasaprecaution.• TurnAssistcanbeactivatedfromeither

sideofthebed.

To Activate:• PresstheEnableControlandtheneither

LeftTurnorRightTurnonthesiderail.

TurnAssistFeature

Turn LTurn R Turn LTurn R

Page 13: Hill-Rom® VersaCare® Bed Tips Simply Effective

13

• Maximizesthefirmnessoftheprimarysectionofthepatientsurface.

• Assistsinpatientsurface-to-surfacetransfersand/orrepositioning.

• BedwillstayinMaxInflatefor30minutesbeforereturningtonormal/standardstate.

To Activate:• PresstheEnableControlandthenpress

theMaxInflatebuttononthesiderail.To Deactivate:

• PresstheenablecontrolandthenpressthePressureRelief/Normalbutton.

MaxInflateFeature

Max. InflateNormal Max. InflateNormal

Page 14: Hill-Rom® VersaCare® Bed Tips Simply Effective

14

• Simplifyandorganizepatientlinestoavoidentanglementorpinching.

• Flexibleandcanbebentinanyposition.• NOTE:Donotwrapcordsaroundtheline

managers.

LineManagers

Page 15: Hill-Rom® VersaCare® Bed Tips Simply Effective

15

• Allowsthepatienttobeplacedintoachairposition,whilemaintaininglowheight.

To Activate:• Setthebrake.• PresstheEnableControlandthenthe

Chairbutton.

LowChair®Position

Chair

Page 16: Hill-Rom® VersaCare® Bed Tips Simply Effective

16

• Sleepmodetemporarilydisablestheairsystemtoallowpatientswhoaresensitivetosleepsurfacemovementtosleep.

• Airpressureinthemattressismonitored,buttheairpumpwillnotrununlesstheairpressurefallsbeloworaboveapresetlevel.

• NOTE:Sleepmoderemainsactivefor8hours.After8hours,thesurfacewillrevertbacktoPressureRelief/NormalMode.

To Activate:• PresstheEnableControl.• SimultaneouslypresstheLeftTurnAssist

andRightTurnAssistcontrolandholdfor5seconds.After5seconds,therightandleftTurnAssistindicatorswillilluminate.

To Deactivate:• PresstheEnableControl.• Pressanysurfacecontrol.• NOTE:Sleepmoderemainsactivefor8

hours.After8hours,thesurfacewillrevertbacktoPressureRelief/NormalMode.

SleepMode

Turn LTurn R Turn LTurn R

Page 17: Hill-Rom® VersaCare® Bed Tips Simply Effective

17

• Ifsilencingbeforethepatientexitsthebed,presstheEnablecontrol(keybutton).

• PresstheAlarmSilencebutton.• Oncethepatientisproperlypositioned

backinbed,thebedwillscanforthepatient’sweightandautomaticallyreset.

• WhenyouhearabeepandseethegreenindicatorlightappearnexttotheBedExitMode,thebedexithasbeenreset.

BedExitAlarmSilence

Page 18: Hill-Rom® VersaCare® Bed Tips Simply Effective

Hill-Rom reserves the right to make changes without notice in design, specifications and models. The only warranty Hill-Rom makes is the express written warranty extended on the sale or rental of its products.

©2013 Hill-Rom Services, Inc. ALL RIGHTS RESERVED.

ORDER NUMBER 184359 rev 1 10/31/2013 ENG – US

Zinc Number US-AC-0713-0335

www.hill-rom.com

USA 800-445-3730 CANADA 800-267-2337

Hill-Rom®VersaCare® Bed TipsSimply Effective TO USE OUR TIPS ON