high-tro-reel (tension type)100a 100a high-tro-reel tro-reel. reduces installation time. 60a/90a...
TRANSCRIPT
HIGH-TRO-REEL (Tension Type)
! Please follow the safety precautions on page 2.
Multi-Lead Indoor Use Insulated Trolleys UL3P・4P 60A UL Listed
35
A recommended power supply system for hoists and cranes. Installed using
tension applied to both ends of the unit.
Reduces installation space to one-third.
Perfect for powering hoists and cranes.
Dependable power collection during travel.
56A
100A 100A
●High-Tro-Reel
●Tro-Reel
Reduces installation time.
60A/90A High-Tro-Reel unit
Joiner body
Lock screw
Terminal screw(M6)
Crimp-onterminal
Joiner cover
Terminal plate
Conductor
Hex key wrench (for M6)
50 meter jointless installation.
Use of a multiple-lead system eliminates the need to provide space between leads as required in conventional insulated trolleys. This results in a space saving of 66% over the Tro-Reel insulated trolley.
4P and 5P types are ideal for hoists and cranes requiring multiple lead wiring (including control leads) in a confined space.
Since the collector arms maintain stable contact pressure, there is less chance for the collectors to become separated from wires due to vibration or swinging.
Processes from unpacking to on-site cutting, setup, mounting onto the hangers and tension application can all be handled with the 3P unit. Its unique configuration eliminates the need for straightening and other adjustments after installation. This reduces installation time compared to conventional insulated trolleys.
High-Tro-Reel coils are 50m long, so there is no need for joints in installations up to 50m. Using joiners can make even lines longer than 50m easy to install. With 60A and 90A units, joiners can supply power from anywhere on the line.
36
60A/90A High-Tro-Reel units (for indoor use only)
●Rating 3P, 4P, 5P; 600V; 60A, 90A●Conductor materials 60A: Steel (8㎟) + Copper (20㎟), 90A: Copper (28㎟)●Insulating sheath material Rigid PVC (heat resistance: 75℃) Orange (hazard color), Munsell 2.5YR 6/13
150A/200A High-Tro-Reel units (for indoor use and machine interior use only)
●Rating 3P, 4P; 600V; 150A, 200A●Conductor material 150A/200A: Copper (46.2㎟)●Insulating sheath materials 150A: Rigid PVC (heat resistance: 75℃) 200A: Rigid PVC (heat resistance: 95℃) Orange (hazard color), Munsell 2.5YR 6/13
56
9620 20 20 20
7620 20 20
20
14
14
14
2014
14
14
15
7620 20 20
14
5620 20
14
15
56
7620
1520 20
20 20
14
14
15
60A
150A 200A
90A
5620
14
2014
7620 20 20
14
14
9620 20 20 20
14
14
●Cross-section
●Cross-section
Cat. No. Rating
3P・600V・60A
4P・600V・60A
5P・600V・60A
Length10m30m50m10m30m50m10m30m50m
Weight (kg)10.230.550.913.841.569.117.151.385.4
DH5761DH5763DH5765DH5762DH5764DH5766DH5767DH5768DH5769
Cat. No. Rating
3P・600V・90A
4P・600V・90A
5P・600V・90A
Length10m30m50m10m30m50m10m30m50m
Weight (kg)10.631.752.814.242.671.017.953.689.3
DH5791DH5793DH5795DH5792DH5794DH5796DH5797DH5798DH5799
Cat. No. Rating
3P・600V・150A
4P・600V・150A
Length10m30m50m10m30m50m
Weight (kg)15.245.575.820.461.1
101.8
DH5751DH5753DH5755DH5752DH5754DH5756
Cat. No. Rating
3P・600V・200A
4P 600V・200A
Length10m30m50m10m30m50m
Weight (kg)15.245.575.820.260.5
100.8
DH5731DH5733DH5735DH5732DH5734DH5736
※5P(DH5767)
※4P(DH5752)
※Available in coil form only. Contact us in case of non-standard length. ※Available in coil form only. Contact us in case of non-standard length.
※Available in coil form only. Contact us in case of non-standard length.
60A (UL Listed ) Cat. No. Rating
3P・600V・60A
4P・600V・60A
Length10m30m50m10m30m50m
Weight (kg)10.230.550.913.841.569.1
DH5761UDH5763UDH5765UDH5762UDH5764UDH5766U
UL
※Available in coil form only. Contact us in case of non-standard length.
3P60A
4P60A
3P150A 3P200A
4P150A 4P200A
5P60A
3P90A
4P90A
5P90A
37
HIGH-TRO-REEL (Tension Type)Note: Refer to page 43 for the products with CE Mark.
UL3P・4P 60A UL Listed
57
80
20 2087
A
400
B
85205
100
65
30
40
100
202087
A B
400
85138100
145
30
40
80
202087
A
400
85126100
40
30
B
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57032K For 3P 1.8 — 1DH57042K For 4P 2.1 — 1DH57052 For 5P 2.4 — 1
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57034K For 3P 1.8 — 1DH57044K For 4P 2.1 — 1DH57054 For 5P 2.4 — 1
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57132K For 3P 1.7 — 1DH57142K For 4P 2.0 — 1DH57152 For 5P 2.3 — 1
100
40
208720
B
138600
100 150
145
30A
40
80
20 2087
A
600126100 150
40
B
3057
80
20 2087
BA
205600
100 150
65
30
B90110130
A120140160
3P4P5P
B90110130
A120140160
3P4P5P
End tention insulator
Attached to both ends of the High-Tro-Reel unit to absorb expansion and contraction due to temperature fluctuations.For 60A, 90A, 150A, and 200A.
Note: Can be used with lines 100m or less in length.
Don't use them again.
After setting the High-Tro-Reel unit, the terminal, and the terminal plate in the end tension insulator. The terminal plate and the terminal where fixed bolt M6×12 was tightened with the specified torque cannot be used again.
Please in quire of store purchased when the terminal and the terminal plate are necessary.
Drawing shows a 3P end tention insulator.
Drawing shows a 3P end tention insulator.
●With feed-in terminal (Cable side-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable side-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable bottom-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable bottom-out type).For 60A, 90A, 150A and 200A.
●Without feed-in terminal.For 60A, 90A, 150A and 200A.
●Without feed-in terminal.For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable side-out type) ●With feed-in terminal (Cable bottom-out type) ●Without feed-in terminal
●With feed-in terminal (Cable side-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable side-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable bottom-out type).For 60A, 90A, 150A and 200A.
●With feed-in terminal (Cable bottom-out type).For 60A, 90A, 150A and 200A.
●Without feed-in terminal.For 60A, 90A, 150A and 200A.
●Without feed-in terminal.For 60A, 90A, 150A and 200A.
End tension insulator for lateral movement
Tension insulator for use in short-distance line internal wiring such as in cranes. Since the end tension insulator comes equipped with inward-facing springs for tension application, the High-Tro-Reel provides the most effective use of factory space.
For installation procedures, please refer to the specialized installation manual.
Don't use them again.
After setting the High-Tro-Reel unit, the terminal, and the terminal plate in the end tension insulator. The terminal plate and the terminal where fixed bolt M6×12 was tightened with the specified torque cannot be used again.
Please in quire of store purchased when the terminal and the terminal plate are necessary.
※3P(DH57032K)
※3P(DH57033K) ※3P(DH57035K) ※3P(DH57133K)
※3P(DH57034K) ※3P(DH57132K)
UL UL ULUL UL UL
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57033K For 3P 1.5 — 1DH57043K For 4P 1.8 — 1DH57053 For 5P 1.8 — 1
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57035K For 3P 1.5 — 1DH57045K For 4P 1.8 — 1DH57055 For 5P 1.8 — 1
Cat. No. Type Weight(kg)
Units perbox
Units percarton
DH57133K For 3P 1.4 — 1DH57143K For 4P 1.7 — 1DH57153 For 5P 1.7 — 1
●With feed-in terminal (Cable side-out type) ●With feed-in terminal (Cable bottom-out type) ●Without feed-in terminal
UL UL ULUL UL UL
38
Unit:mm
Center feed-in joiner
56 62
2020
8317131015 345
138
Joiner
Used to connect High-Tro-Reel units. Can also supply power from anywhere on the line (60A and 90A types).
Used to feed power from anywhere on the line and connect the High-Tro-Reel units (150A and 200A types).For 150A and 200A.
120
A
46
20 20
B
●With feed-in terminalFor 60A and 90A
●Without feed-in terminalFor 150A and 200A
Drawing shows a 3P joiner.
Drawing shows a 3P center feed-in joiner.
※4P(DH57271)
It mounts main units on the structural materials.It can be used for non-tension type, too.For 60A, 90A, 150A and 200A.
Drawing shows 3P and 5P hangers.3P and 4P types are not equipped with a φ 6.5mm hole.
11.5
A
B
4025
25
For 3P and 4P For 5P
※5P (DH5775K2)
※4P(DH5727K1)※4P(DH5724K2)
A B6282
102
7090
110
3P4P5P
Cat. No. Type Rating Weight(kg)
Units perbox
Units percarton
For 3P, 60A/90AFor 4P, 60A/90AFor 5P, 60A/90A
For 3P, 150A/200AFor 4P, 150A/200A
3P・600V・90A4P・600V・90A5P・600V・90A
3P・600V・200A4P・600V・200A
0.180.310.370.200.26
11111
2010102010
DH5723K DH5724K2 DH5725 DH5726 DH5727K1
Cat. No. Type
For 3PFor 4PFor 5P
Weight(kg)0.060.070.08
Units perbox201010
Units percarton
1005050
DH5773K2DH5774K2DH5775K2
Cat. No. Type Rating
For 3P, 150A/200AFor 4P, 150A/200A
3P・600V・200A4P・600V・200A
Weight(kg)1.92.2
Units perbox——
Units percarton
11
DH57261DH57271
A B6989
5676
3P4P
ULUL
Hanger UL Listed UL
60
4025
25
13
96
109
39
HIGH-TRO-REEL(Tension Type)
Cat. No. Weight(kg)
Units perbox
Units percarton
DH5249K 0.13 1 24
Cat. No. Rating Weight(kg)
Units perbox
Units percarton
Collector arm
Attached to the moving equipment and used to supply power from the High-Tro-Reel unit to the equipment.
●Single type
0.670.981.080.811.161.321.061.41
3P・600V・30A4P・600V・30A5P・600V・30A3P・600V・60A4P・600V・60A5P・600V・60A3P・600V・100A4P・600V・100A
————————
11111111
DH5743K3DH5744K3DH5745K2DH5746K2DH5747K2DH5748K2DH5741K2DH5742K2
※4P(DH5744K3)
A
7
270
72 46
90±
20 4823
3.5-5S
Collector arms can be linked together and used in tandem configuration when it is critical that the collectors are not separated from the wires.
※Drawing shows 4P collector arm.
557095
3.5-5S8-614-6
30A60A
100A
A Crimp-on terminal
Cat. No. Rating Units perbox
Units percarton
Collector (replacement parts)
The number of collectors in a set conforms to the number of poles. Replace collectors when they wear down to the replacement indication line (approx. 5,000km).
BA
500
267
5
6
Replacement line
3P・600V・30A4P・600V・30A5P・600V・30A3P・600V・60A4P・600V・60A5P・600V・60A3P・600V・100A4P・600V・100A
11111111
3020203020202010
DH5783K1DH5784K1DH5785K1DH5786K1DH5787K1DH5788K1DH5781K2DH5782K2
A B Crimp-on terminal85
100125
3.5-5S8-614-6
557095
30A60A
100A
※3P(DH5783K1)
12848
15366
55 52
The above shows when it is installed.
Collector arm support parts for transverese
●Applicate for 30A, 60A, and 100A collector arms.●When installing a collector arm horizontally, mounted collector arm
support parts for transverse on base of the collector arm as shown.
ULUL
40
Unit:mm
HIGH-TRO-REEL(Tension Type)