1
Problem: CBRxxxx_xxx_S01 have high RTWP due Loose connection of jumper. Analysis: 1) Check the RTWP. 2) Check the primary and secondary RTWP gap. Solution: When we checked the primary and Secondary RTWP in LMT we found it have high difference As we checked the Neb. site RTWP is normal then we suspect to have loose connection. When TE team has tighten the cable and connector RTWP become normal and difference also very less.

Upload: krissze

Post on 17-Sep-2015

20 views

Category:

Documents


8 download

DESCRIPTION

rtwp

TRANSCRIPT

Problem: CBRxxxx_xxx_S01 have high RTWP due Loose connection of jumper.

Analysis:1) Check the RTWP.

2) Check the primary and secondary RTWP gap.

Solution: When we checked the primary and Secondary RTWP in LMT we found it have high difference As we checked the Neb. site RTWP is normal then we suspect to have loose connection. When TE team has tighten the cable and connector RTWP become normal and difference also very less.