We bring together the best people with the best tools and processes to provide start-to-finish coordination of architecture and engineering. Our approach focuses on innovation from design concept through commissioning; from procurement of long lead equipment through systems integration; from the way we document project information to the way we report it.

TRANSCRIPT

  • High Performance Computing

    High Performance Computing

  • 2012 IDC Architects Confidential and Proprietary IAT102711193553PDX

    A New ParadigmToday, successful delivery of high performance data centers is built on a new paradigm. The facilities that support providers of scalable and virtualized resources demand innovation at every level from the design of the facility itself, to the way in which the project is delivered, and the people who deliver it.

    The work of IDC Architects (IDCA) embodies that new paradigm. We bring together the best people with the best tools and processes to provide start-to-finish coordination of architecture and engineering. Our approach focuses on innovation from design concept through commissioning; from procurement of long lead equipment through systems integration; from the way we document project information to the way we report it.

    Its about creating an environment where innovation and invention flourish, people work to their highest potential, and best value is captured for our clients. It means never settling for the status quo, always asking what if. Its a philosophy and a culture weve forged and refined over two decades of partnering with demanding clients to deliver the most challenging data center projects in the world.

  • 2012 IDC Architects Confidential and Proprietary IAT102711193553PDX

    The Basis of Design A Framework for SuccessWhat are your true requirements? This question is at the heart of our design process. Our approach is vendor-neutral were not selling pre-packaged solutions. Instead, we start with a collaborative programming effort, working with you to tightly define your project requirements. The resulting Basis of Design is a roadmap to success aligning scope and budget, maximizing constructability, and providing a framework for effective change management.

    High Performance Design ToolsWe validate decisions early in the concept phase utilizing our 3D rapid prototyping process, computational fluid dynamics (CFD) modeling, and energy and structural analysis programs. These powerful tools help fine-tune project solutions by test-driving our designs.

    3D Rapid PrototypingThis interactive design process allows us to quickly test different functional layouts. As specific information is acquired during programming, we build a working 3D model of each functional area. By evaluating massing and spatial arrangements in real time, we immediately see how different decisions impact flexibility, adjacencies, and overall building form. This tool builds consensus, greatly reduces project risk, and avoid later changes that can impact cost and schedule.

    Whether your goal is a new building, or retrofit of an existing facility, look to the leader in mission critical planning, design and construction IDC Architects.

  • 2012 IDC Architects Confidential and Proprietary IAT102711193553PDX

    Airflow ModelingParticularly valuable in data centers, airflow modeling (using Computational Fluid Dynamics, or CFD) helps evaluate the environmental performance of a facility, apply innovative energy efficiency measures, and implement sustainable design strategies such as natural ventilation.

    Sustainable SolutionsAt IDCA, we re-thought mission critical green design from the ground up, with ideas like hot and cold aisle separation, innovative use of outside air, and optimal site orientation. By focusing on the specific goals of each customer and the unique opportunities of each site we deliver world-class performance, great people spaces, and cost savings over the life of the facility.

    Integrated Architecture and EngineeringBy focusing on the synergy between architecture, engineering, and planning, our design process is uniquely suited to the demands of todays next-generation data centers. Our teams of architects and engineers are located in project team spaces, enhancing communication and collaboration. This integrated approach is a powerful platform for innovation.

  • 2012 IDC Architects Confidential and Proprietary Page | 4IAT102711193553PDX

    Mission Critical Design ExpertiseIDCA has designed mission critical data centers and core IT infrastructure for the worlds leading technology companies. Our 20 years of experience with advanced technology data centers and associated space has placed us at the forefront of mission critical design. Some of our recent projects are highlighted.

    Terremark Amsterdam

    This top-tier European data center was strategically built to access one of the worlds largest Internet hubs in terms of traffic and members. The flagship facility provides 25,000 SF of data center space to meet regional demand for advanced cloud computing, security and IT infrastructure services.

    Stringent requirements for security, performance and reliability

    Flywheel UPS system

    Innovative free cooling loop utilizing dry coolers indirect HX to provide chilled water without use of mechanical cooling for substantial periods of the year

    High use of swing equipment to provide high level of redundancy on plant systems at reduced initial capital cost

    Architectural planning achieved within the tight planning constraints of the local jurisdiction

    On time and on budget project delivery

    * Due to a confidentiality agreement with this client, we are unable to show imagery from this project. (representative image shown)

  • 2012 IDC Architects Confidential and Proprietary IAT102711193553PDX

    Confidential Client North Carolina, USA

    This facility showcases the cloud computing technology of a world leading IT company. The LEED Gold certified data center uses half the energy required by similar sized facilities. The integrated modular design allows for rapid capacity scale-up and efficient expansion; the data center will ultimately total 100,000 square feet.

    Showcase facility for the clients world-leading technology services

    Schedule savings - data center began to support client operations within 15 months, as compared to industry benchmark of 18-24 months

    Energy savings cooling with outside air cuts energy use by half. Intelligent systems continuously read temperature and relative humidity to adjust cooling in response to changes in demand

    LEED Gold certification

  • 2012 IDC Architects Confidential and Proprietary IAT102711193553PDX

    Confidential Client,Virginia, USA

    After developing the initial basis of design (BOD), IDC Architects is providing full design services to convert over one million SF of semiconductor manufacturing space for data center use. The fully converted facility will consist of five major buildings; with over 500,000 SF of raised floor space it is the largest data center complex in the world. The project met aggressive schedule challenges to support the clients business plan, with the initial 12,000 SF of raised floor designed in just 60 days.

    Worlds largest data center complex

    Raised floor within white space to accommodate air management and flexibility

    Innovative flexible multi-tier distribution approach for varying customer needs

    Sustainable design with consideration for LEED (Silver or Gold)

    RegenceSalt Lake City, Utah

    IDCA performed a facility evaluation to provide Regence with a comprehensive understanding of its critical data center facilities. Based on the findings, we developed a master plan that recommended a new electrical infrastructure for the campus, and, to elevate data center reliability, segregation of data center power from office building power. Options were developed to respond to long term growth requirements. Finally, IDCA provided detailed design for new campus infrastructure and comprehensive upgrades that improve reliability, and position the facility for future capacity to support Regence corporate requirements.

    Evaluation of electrical system capacities, historical load analysis, system configuration, equipment condition

    Master planning

    Design for new campus infrastructure and upgrades

    Civil, structural, architectural, mechanical, electrical services during construction

    * Due to a confidentiality agreement with this client, we are unable to show imagery from the project. (representative image shown)

  • About IDC ArchitectsIDC Architects is an integrated, multidisciplinary planning and design firm focused on science and technology, with a global presence and a singular vision: to discover better ways for people, technology, buildings, and the environment to work together. Our integrated method of architectural and engineering design produces sound master plans, functional and flexible spaces, reliable building systems, and sustainable solutions, achieved through a highly collaborative process that fully engages all project stakeholders.

    As a CH2M HILL company, IDC Architects has access to the resources of a global leader in full-service consulting, design, design-build, operations, and program management for public and private clients. With US$6.3 billion in revenue and more than 30,000 employees worldwide, CH2M HILL delivers innovative, practical, sustainable solutionshelping clients develop and manage infrastructure and facilities that improve efficiency, safety, and quality of life. The firm has long been recognized as a most-admired company and leading employer. CH2M HILL is an industry-leading program management, construction management, and design firm as ranked by Engineering News-Record (2011).