hi-vni technology on the go26.20...hi-vni® technology on the go vapotherm, inc. • 100 domain...

2
Ambulate and Transfer patients without compromising respiratory support. Maintain L/min rate, FiO 2 , temperature, and humidification levels Seamless transition from cylinders to wall gas Easy hot swap of patient circuit onto a stationary unit Enhanced with new light, fast charging Lithium-ion baery Technical Specifications The Vapotherm Transfer Unit includes the Precision Flow ® roll stand, medical grade mobile power system, Gas Manifold, and E cylinder holder Performance Allows the mobile delivery of Hi-VNI Technology within a hospital environment. Vapotherm ® Transfer Unit Hi-VNI ® Technology on the GO

Upload: others

Post on 04-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hi-VNI Technology on the GO26.20...Hi-VNI® Technology on the GO Vapotherm, Inc. • 100 Domain Drive • Exeter, NH 03833 • 603.658.0011 • MKT-0113 Rev B 12/18 Tank gas supply:

Ambulate and Transfer patients without compromising respiratory support.

• Maintain L/min rate, FiO2, temperature, and humidification levels• Seamless transition from cylinders to wall gas• Easy hot swap of patient circuit onto a stationary unit

Enhanced with new light, fast charging Lithium-ion battery

Technical SpecificationsThe Vapotherm Transfer Unit includes the Precision Flow® roll stand, medical grade mobile power system, Gas Manifold, and E cylinder holder

PerformanceAllows the mobile delivery of Hi-VNI Technology within a hospital environment.

Vapotherm® Transfer Unit

Hi-VNI® Technology on the GO

Page 2: Hi-VNI Technology on the GO26.20...Hi-VNI® Technology on the GO Vapotherm, Inc. • 100 Domain Drive • Exeter, NH 03833 • 603.658.0011 • MKT-0113 Rev B 12/18 Tank gas supply:

Hi-VNI® Technology on the GO

Vapotherm, Inc. • 100 Domain Drive • Exeter, NH 03833 • 603.658.0011 • www.vapotherm.comMKT-0113 Rev B 12/18

Tank gas supply: Mobile run time will vary depending on the O2/air blend and L/min rate settings on the Precision Flow.

Battery life: Up to 1 hour. Recharging time: Less than 3 hours, as displayed on the remote user interface.

System Requirements• 100 to 240 VAC Universal Input (to charge battery)• Oxygen E-Cylinder regulated to 60 psi• Oxygen E-Cylinder regulator (not included) • Air E-Cylinder regulated to 60 psi• Air E-Cylinder regulator (US Only)• Vapotherm Precision Flow or Precision Flow Plus

Sample Estimates

L/min Rate FiO2 Approximate Time in Minutes

4 50% 170

4 100% 140

25 50% 27

25 21% or 100% 22

40 50% 17

40 21% or 100% 14