hhhe-qc-fo-086
TRANSCRIPT
Order / Drg No: Material :
Min .(SOD): Max.(OFD) :
Sensitivity Requirment: Density Requirment: Source Strength (Energy) : Ci Kv
No.of Films /Cassette: Film Size: Source Size/Focal Spot : Film Brand and Designation :
IQI Location :
Weld No Welder No Area of interest
DWDI :Double Wall Double Image
Date
Signature
Level
Name
UC :Undercut EP : Excess Penetration
TI :Tungsten InclusionSL :Slag Inclusion
SWSI : Single Wall Single Image
Client Representative. ASME A.I / Third Party if required
HB :Hollow Bead
NDE Inspector
CR : Crack IF : Incomplet Fusion IP : Incomplet Penetration
CON : Concavity
CP :Cluster Prosity
P :Prosity
DWSI : Double Wall Single Image
Client : Project No :
Page No.
Thk :
Equipment and Matrial
Remarks
RADIOGRAPHIC EXAMINATION REPORT
Form No:
HHE-QC-FO-086
Issue A/1
Report No :
Item / Mark
Surface Temp: Room Temp
Radiation Source : Ir.192 X Ray
Mark / Item No:
Location :
Request No :
Surface condition: As Weld
SOD :Source to Object Distance OFD: Source side of object to Film Distance
of
Interpretation Result
Film Processing : Manual Automatic
Lead Screens : Front Back NonExposure / Viewing Technique : DWSI DWDI SWSI
IQI Type : Wire Hole
Order. No / Drg. No
Technique Description
Reference procedure Specification : HHE-QC-WP-019
Acceptance Criteria :